Number
2.6.27
                                                                                                          Subject
                                                                                                            Thermal Stress, Convection Reflow Assembly
                                                  3000 Lakeside Drive, Suite 105N                           Simulation
                                                    Bannockburn, IL 60015-1249
                                                                                                          Date                               Revision
                                                                                                            2/2020                           B
                                                                                                          Originating Task Group
            IPC-TM-650                                                                                      Thermal Stress Test Methodology Subcommittee
      TEST METHODS MANUAL                                                                                   (D-32)
1 Scope and Purpose                                                                                     3 Test Specimen
1.1 Scope This method is intended to simulate exposure to                                               3.1 Design/Construction Criteria
the thermal conditions by convection reflow assembly.
                                                                                                        3.1.1 The test specimen shall be the A/B, AB-R, and/or the
1.2 Purpose      This method shall be used to replicate the                                             D coupon as designed in accordance with the requirements of
thermodynamic effects by assembly on the test specimen.                                                 IPC-2221 Appendix A or B. Use of alternate specimens shall
The use of this method is intended to simulate those effects                                            be AABUS.
that are the result of soldering thermal excursions.
                                                                                                        3.1.2 The test specimen(s) shall be constructed with holes
1.2.1   This method shall be used for qualification testing of                                          contained in the printed board it represents as follows:
an applicable test specimen. The evaluation of acceptability                                            a. A/B, A/B-R and D coupons shall be constructed with
for qualification shall be in accordance with the requirements                                             both the largest plated through-holes (PTHs) and the
defined in 5.3.                                                                                            smallest vias.
1.2.2   This method may be used for lot acceptance. The                                                 b. Propagated B and D coupons shall be constructed with
evaluation for lot acceptability should be in accordance with                                              the intended via structure. (Multiple B and D coupons are
the requirements defined in 5.3 or as agreed upon between                                                  used for designs with multiple structures.)
user and supplier (AABUS).                                                                              3.1.2.1   The test specimen(s) shall contain the representa-
                                                                                                        tive ground and power planes of the printed board design.
2 Applicable Documents
IPC-T-50        Terms and Definitions                                                                   3.1.2.2     The test specimen(s) shall contain the representa-
                                                                                                        tive filled through vias, applicable blind and/or buried vias,
IPC-2221         Generic Standard on Printed Board Design                                               including microvias, of the printed board design.
IPC-A-600          Acceptability of Printed Boards
                                                                                                        3.1.3   The test specimen(s) shall allow for microsection
IPC-1601         Printed Board Handling and Storage Guidelines                                          evaluation of all the applicable, representative PTHs and vias
                                                                                                        defined in 3.1.2 after exposure to the conditions of this Test
IPC-6012 Qualification and Performance Specification for
                                                                                                        Method.
Rigid Printed Boards
                                                                                                        Note: Special tooling may be required for potting an entire
IPC-6013     Qualification and Performance Specification for
                                                                                                        ‘‘D’’ Coupon for microsection examination.
Flexible Printed Boards
IPC-6018  Qualification and Performance Specification for                                               3.1.4 Deviations to the test specimen design/construction
High Frequency (Microwave) Printed Boards                                                               or use of an alternate test specimen such as the printed board
                                                                                                        or a section of the printed board shall be AABUS.
IPC-9241         Guidelines for Microsection Preparation
                                                                                                        4 Apparatus
IPC-9631         User’s Guide for IPC-TM-650, Method 2.6.27
IPC-TM-650           Test Methods Manual1                                                               4.1 Drying Oven
2.1.1         Microsectioning – Microsectioning, Manual and Semi                                        4.1.1 The oven shall be capable of maintaining a uniform
              or Automatic Method                                                                       set temperature within the 105 to 125 °C [221 to 257 °F]
                                                                                                        range.
1. Current and revised IPC Test Methods are available on the IPC Web site (www.ipc.org/test-methods.aspx).
Material in this Test Methods Manual was voluntarily established by Technical Committees of IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this              Page 1 of 10
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by IPC.
                                                             IPC-TM-650
 Number                      Subject                                                                     Date
   2.6.27                      Thermal Stress, Convection Reflow Assembly Simulation                        2/2020
 Revision
   B
4.2 Convection Reflow Oven or Simulator                             5.1 Conditioning
4.2.1   The system used to simulate the thermodynamic               5.1.1 The test specimen shall be conditioned by drying in an
effects of assembly shall be convection reflow.                     oven to remove moisture for a minimum of six (6) hours at 105 to
                                                                    125 °C [221 to 257 °F].
4.2.1.1   The system shall have adequate environmental
controls to maintain the tolerance range and limits in accor-       5.1.2 Test specimens that are thicker or more complex may
dance with the reflow profile depicted in either Figure 5-1,        require longer baking times to achieve acceptable moisture
Figure 5-2 or Figure 5-3.                                           levels. Record the bake times and temperature if different than
                                                                    those stated in 5.1.1. See IPC-1601 for additional guidance
4.2.1.2 The system should accommodate verifiable calibra-           on baking to achieve acceptable moisture levels. See note
tion compliance and reflow profile generation. See note 6.1 for     6.2.
additional considerations.
                                                                    5.1.3 Deviations to the conditioning requirements in 5.1.1
4.2.1.3   The test specimen shall be handled and stored in a        such as when used for acceptance criteria and/or any
controlled environment to minimize moisture ingression. See         changes to the time and temperature shall be AABUS. See
IPC-1601 for details on the proper handling and storage of          6.3.
test specimens.
                                                                    5.2 Reflow Profile
4.2.2  Deviations to the equipment requirements and
                                                                    5.2.1 Reflow the test specimen in accordance with Table
acceptability of the alternative methods shall be AABUS.
                                                                    5-1 (default), Table 5-2 (low temperature profile) or Table 5-3.
4.3 Microscope
                                                                    5.2.2 The reflow profile shall be in accordance with either
4.3.1 The magnification used for defect recognition must be         Figure 5-1, Figure 5-2 or Figure 5-3. Figure 5-1 represents the
in agreement with the inspection requirements/capabilities          default reflow profile. Figure 5-2 represents the low tempera-
defined in the applicable performance specification (e.g., IPC-     ture profile. Figure 5-3 represents a 245 °C reflow profile. The
6012, IPC-6013, IPC-6018, etc.) and IPC-A-600.                      times to t1, t2 and t3 may vary based on the mass of the
                                                                    sample test specimen. To avoid over stressing of samples,
4.4 Resistance Measurements of IPC-2221 Appendix A,                 times should be shortened for low mass samples. Times
D Coupons                                                           should be extended for high mass samples, such that the
                                                                    zone (air) temperature shall not be more than 25 °C above
4.4.1 When specified by performance specification or pro-           the target surface temperature at any point in the cycle.
curement documentation, resistance measurements of the
IPC-2221B Appendix A, D coupons shall be required.                  The attachment of thermocouples to the sample test speci-
                                                                    men shall be such that the reflow profile is calibrated to the
4.4.2 The resistance measurement shall have enough pre-             surface temperature of the test specimen.
cision to clearly determine the resistance percent change as
required by the user for the resistance level of each sample’s      5.2.3    The test specimen shall be subjected to a minimum
nets.                                                               of six (6) reflow cycles.
                                                                    5.2.4 The cool down rate shall be in accordance with Table
4.4.3    The total system uncertainty from resistance, tem-
                                                                    5-1, Table 5-2 or Table 5-3, based on the reflow profile
perature and time/cycle variations shall be less than 10% of
                                                                    selected in 5.2.1. The cool down is complete when the test
the failure criteria required by the user. For example, if the
                                                                    specimen reaches 45 °C. The test specimen shall achieve a
required failure criteria is 5% then the total system uncertainty
                                                                    thermal equilibrium of 45 °C or less prior to starting the next
shall be no greater than 0.50%.
                                                                    reflow cycle. If the time it takes to achieve thermal equilibrium
4.4.4  The resistance data shall consist of at least 1 reading      cannot be determined, then a five (5) minute dwell between
per sample net every second during the entire reflow cycle.         reflow cycles shall be required.
5 Procedure                                                         5.2.5 Deviations to the reflow profile or number of cycles
                                                                    shall be AABUS.
Page 2 of 10
                                                         IPC-TM-650
Number                 Subject                                                                        Date
  2.6.27                 Thermal Stress, Convection Reflow Assembly Simulation                          2/2020
Revision
  B
                         Table 5-1       260 °C Nominal Reflow Profile Specifications (Default)*
            Value          Time (Seconds)                Temperature (°C)                          Description
              t1                 210 ± 15                        –                           Target preheat time
              t2                 270 ± 10                        –                         Target peak reflow time
              t3                 330 ± 15                        –                       Target cool-down start time
            t3 - t1              120 ± 30                        –                          Target time above T1
              T1                     –                          230                    Maximum preheat temperature
              T2                     –                        260 ± 5                     Target reflow temperature
            Point          Time (Seconds)                Temperature (°C)                       Description
              A                      0                          30
              B                    100                          230
              C                    195                          230
              D                    255                          265                    Upper specification limit values
              E                    285                          265
              F                    345                          230
              G                    550                          30
              H                    30                           30
               I                   157                          93
              J                    225                          230
              K                    260                          255                    Lower specification limit values
              L                    280                          255
              M                    315                          230
              N                    383                          30
       Segment                            Slope (°C / second)                                   Description
           A-B & I-J                               2.0                                     Maximum preheat rate
              H-I                                  0.5                                     Minimum preheat rate
             F-G                                  -1.0                                    Minimum cool-down rate
             M-N                                  -3.0                                    Maximum cool-down rate
                                                                                                             Page 3 of 10
                                                                                               IPC-TM-650
 Number                                           Subject                                                                                          Date
   2.6.27                                           Thermal Stress, Convection Reflow Assembly Simulation                                            2/2020
 Revision
   B
                                                              260 °C Reflow Profile Specifications
                                                                                t1                 t2                 t3
                               300
                                                                                                                                             USL   LSL         Example
                                                                                               D        E
                               270
                                                                                                                                                                         T2
                                                       B                    C                  K        L                  F
                               240
                                                                                                                                                                         T1
                                                                                     J                            M
                               210
            Temperature (°C)
                               180
                               150
                               120
                               90
                                                                  I
                               60
                                     A                                                                                                                     G
                               30
                                     0   H   60             120       180                240                300                360 N   420   480         540         600
                                                                                                Time (Seconds)
                                                                                                                                                                         IPC-2627-5-1
Figure 5-1                     260 °C Nominal Reflow Profile Chart (Default)*
Page 4 of 10
                                                             IPC-TM-650
Number                       Subject                                                                   Date
  2.6.27                       Thermal Stress, Convection Reflow Assembly Simulation                     2/2020
Revision
  B
                       Table 5-2   230 °C Nominal Reflow Profile Specifications (Low Temperature Profile)*
            Value                  Time (Seconds)            Temperature (°C)                     Description
              t1                       186 ± 15                       –                       Target preheat time
              t2                       239 ± 10                       –                     Target peak reflow time
              t3                       292 ± 15                       –                   Target cool-down start time
            t3 - t1                    106 ± 30                       –                      Target time above T1
              T1                          –                          203                 Maximum preheat temperature
              T2                          –                      230 ± 5                   Target reflow temperature
            Point                  Time (Seconds)            Temperature (°C)                     Description
              A                           0                          30
              B                          88                          203
              C                          172                         203
              D                          226                         235                 Upper specification limit values
              E                          252                         235
              F                          305                         203
              G                          487                         30
              H                          30                          30
               I                         139                         83
              J                          199                         203
              K                          230                         225                 Lower specification limit values
              L                          248                         225
              M                          279                         203
              N                          339                         30
       Segment                                 Slope (°C / second)                                Description
           A-B & I-J                                   2.0                                   Maximum preheat rate
              H-I                                      0.5                                   Minimum preheat rate
             F-G                                      -1.0                                  Minimum cool-down rate
             M-N                                      -3.0                                 Maximum cool-down rate
                                                                                                               Page 5 of 10
                                                                                         IPC-TM-650
 Number                                       Subject                                                                         Date
   2.6.27                                         Thermal Stress, Convection Reflow Assembly Simulation                         2/2020
 Revision
   B
                                                          230 °C Reflow Profile Specifications
                                                                      t1           t2            t3
                               300
                                                                                                                        USL   LSL     Example
                               270
                                                                               D        E
                               240
                                                                                                                                                T2
                                                  B               C            K        L             F
                               210
            Temperature (°C)
                                                                                                                                                T1
                                                                           J                 M
                               180
                               150
                               120
                               90
                                                              I
                               60
                                     A                                                                                    G
                               30
                                     0   H   60         120       180              240            300     N 360   420   480     540         600
                                                                                            Time (Seconds)
                                                                                                                                                IPC-2627-5-2
Figure 5-2                     230 °C Nominal Reflow Profile Chart (Low Temperature Profile)*
Page 6 of 10
                                                         IPC-TM-650
Number                 Subject                                                                       Date
  2.6.27                 Thermal Stress, Convection Reflow Assembly Simulation                         2/2020
Revision
  B
                                 Table 5-3   245 °C Nominal Reflow Profile Specifications*
            Value          Time (Seconds)                Temperature (°C)                        Description
              t1                  198 ± 15                       –                            Target preheat time
              t2                  254 ± 10                       –                       Target peak reflow time
              t3                  311 ± 15                       –                     Target cool-down start time
            t3 - t1               113 ± 30                       –                           Target time above T1
              T1                     –                          217                   Maximum preheat temperature
              T2                     –                       245 ± 5                    Target reflow temperature
            Point          Time (Seconds)                Temperature (°C)                        Description
              A                      0                          30
              B                      94                         217
              C                     184                         217
              D                     240                         250                   Upper specification limit values
              E                     269                         250
              F                     325                         217
              G                     518                         30
              H                      30                         30
               I                    148                         88
              J                     212                         217
              K                     245                         240                   Lower specification limit values
              L                     264                         240
              M                     297                         217
              N                     361                         30
       Segment                            Slope (°C / second)                                    Description
           A-B & I-J                              2.0                                        Maximum preheat rate
              H-I                                 0.5                                        Minimum preheat rate
             F-G                                  -1.0                                   Minimum cool-down rate
             M-N                                  -3.0                                  Maximum cool-down rate
                                                                                                             Page 7 of 10
                                                        IPC-TM-650
 Number                   Subject                                                      Date
   2.6.27                    Thermal Stress, Convection Reflow Assembly Simulation      2/2020
 Revision
   B
                                                                                                 IPC-2627-5-3
Figure 5-3   245 °C Nominal Reflow Profile Chart*
* The times to t1, t2 and t3 may vary based on the mass of the sample test specimen.
Page 8 of 10
                                                             IPC-TM-650
 Number                      Subject                                                                    Date
   2.6.27                      Thermal Stress, Convection Reflow Assembly Simulation                      2/2020
 Revision
   B
5.3    Evaluation                                                   applicable test specimen designs encountered. Some issues
                                                                    to consider are as follows:
5.3.1 Microsection The test specimen shall be microsec-
                                                                    • Thermal mass compensation capability (energy vs. time)
tioned when this test method is used for thermal stress prior
to structural integrity evaluation. After the test specimen has     • Environmental control capability (heating and cooling)
been conditioned and reflowed in accordance with the
                                                                    • Reproducibility of parameters
requirements of 5.1 and 5.2, microsection the test specimen
in accordance with IPC TM-650 Method 2.1.1. Inspect speci-          • Preheat
mens required for microsection (e.g., A, B, A/B, AB/R, etc.) for
                                                                    • Conveyor speed (if applicable)
compliance to the applicable performance specification
and/or AABUS requirement.                                           • Heating ramp rate
Note: For guidelines on microsection preparation see IPC-           • Cool down rate
9241.
                                                                    • Programming capability
5.3.2 Resistance Change Resistance change shall be                  • Profile memory
used to evaluate IPC-2221 Appendix A (latest revision)
                                                                    The IPC-TM-650 website provides a non-comprehensive list-
D-coupons for performance-based evaluation of the samples
                                                                    ing of providers of convection reflow systems suitable for
when specified. Microsectioning of D coupons which have
                                                                    meeting the reflow profiles within this test method.
been evaluated by resistance change is not required.
                                                                    6.2  Deviations to the time and temperature specified in 5.1.1
5.3.2.1    Percent change in resistances of each sample’s
                                                                    should take into consideration maintaining the solderability of
nets shall be determined using the first cycle’s peak tempera-
                                                                    the surface finish being utilized.
ture resistance as the reference.
                                                                    6.3 Example Drawing Notes As this method addresses
5.3.2.2   The maximum allowable percent change in resis-
                                                                    assembly issues with printed boards, it is recommended that
tance after the test specimen has been conditioned and
                                                                    the user of the printed board establish a drawing note in the
reflowed in accordance with 5.1 and 5.2 shall be 5% maxi-
                                                                    procurement documentation to provide the printed board fab-
mum unless otherwise specified.
                                                                    ricators with guidance relative to the intended reflow process
                                                                    of the printed board. An example of such a drawing note is
5.3.2.3 Cycles to failure, corresponding percent change of
                                                                    provided as follows:
the failure, and the percent change of the final cycle shall be
documented.                                                         A. IPC D COUPONS SHALL BE DESIGNED IAW IPC-2221
                                                                       APPENDIX A AND SHALL INCLUDE COMPONENT (A),
5.3.3 Deviations to the stated requirements or additional              VIA (B) AND ALL PROPAGATED B STRUCTURES. X OF
requirements defined here shall be AABUS.                              EACH COUPON DESIGN SHALL BE TESTED PER
                                                                       MANUFACTURING PANEL.
6 Notes                                                             B. THE IPC D COUPONS SHALL BE SUBJECTED TO 6
                                                                       REFLOW SIMULATIONS IAW IPC-TM-650, METHOD
6.1    The design of the convection reflow system should be            2.6.27 USING THE [230 °C, 245 °C, OR 260 °C] PRO-
flexible enough to facilitate the creation of the reflow profiles      FILE. ACCEPTANCE CRITERIA SHALL BE < 5%
depicted in Figure 5-1, Figure 5-2 and Figure 5-3 for all the          CHANGE IN RESISTANCE.
                                                                                                                Page 9 of 10
                                          IPC-TM-650
 Number         Subject                                                   Date
   2.6.27         Thermal Stress, Convection Reflow Assembly Simulation    2/2020
 Revision
   B
                               This Page Intentionally Left Blank
Page 10 of 10