Tray Design for Chemical Engineers

The document discusses various types of tray technologies used in distillation columns. It describes factors like capacity, efficiency, pressure drop, and fouling tendency for different tray types including sieve trays, bubble cap trays, floating trays, and V-grid trays. It also explains concepts like F-factor, and covers liquid and vapor handling devices, perforated tray designs, downcomers, and lifted decks that enhance capacity and efficiency. High performance trays like VG Plus, StepArc, ModArc, and truncated designs are highlighted.

Uploaded by

Vicente Regulez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
170 views64 pages

Tray Design for Chemical Engineers

The document discusses various types of tray technologies used in distillation columns. It describes factors like capacity, efficiency, pressure drop, and fouling tendency for different tray types including sieve trays, bubble cap trays, floating trays, and V-grid trays. It also explains concepts like F-factor, and covers liquid and vapor handling devices, perforated tray designs, downcomers, and lifted decks that enhance capacity and efficiency. High performance trays like VG Plus, StepArc, ModArc, and truncated designs are highlighted.

Uploaded by

Vicente Regulez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 64

Tray Technology

Chandrakant Joshi | Head Applications and Technology | February 24, 2016


F -Factor Sulzer Chemtech

1. F-factor is the vapor capacity term calculated as the vapor


velocity multiplied by the square root of the vapor density.
2. It can be based either on bubbling area(Fb) or column
superficial area(Fs).

2
How Trays Work Sulzer Chemtech

3
How Trays Work Sulzer Chemtech

4
How Trays Work Sulzer Chemtech

5
How Trays Work Sulzer Chemtech

6
How Trays Work Sulzer Chemtech

7
How Trays Work Sulzer Chemtech

8
How Tray works ? Sulzer Chemtech

9
How Trays Work Sulzer Chemtech

10
Sulzer Chemtech

11
Sulzer Chemtech

12
Sulzer Chemtech

13
Sulzer Chemtech

14
Type of contacting devices on active area Sulzer Chemtech

15
Sieve Tray Sulzer Chemtech

• Hole ID: 3 mm ~ 25.4 mm


• Big size (>20 mm) could be considered for fouling service 16
Bubble Cap
Sulzer Chemtech

FRI 3 & 4 & 6 inches

vertical distance
• Significantly lower turndown (1:8)
• High pressure drop TS
• High entrainment
• High liquid gradient bubble height
• Expensive
vapour velocity m/s

entrainment accelerating path

3 & 4 in 6 in

17
Types of Perforations
Float Valve Sulzer Chemtech

RV4 has a similar capacity to RV1, but less dry drop

18
Types of Perforations
Float Valve Sulzer Chemtech

Snap In
• easy to install and minimize damage
• mainly used with Shell CS & Shell HiFi

Caged Valve
• less dry drop
• as in the partially open status, dry drop ~ the weight of the moving
plate

19
Types of Perforations
Round Float Valve trays Sulzer Chemtech

20
Types of Perforations
Round and Caged Float Valve trays Sulzer Chemtech

21
Types of Perforations
Float Valve Sulzer Chemtech

BDH
Advantages:
• No rotation, broad leg
• Minimize liquid gradient, lateral release
• Minimize weeping, orientation is parallel to liquid flow

22
Types of Perforations
Float Valve Sulzer Chemtech

Advantages:
• No rotation, broad leg
• Minimize liquid gradient, lateral release
• Minimize weeping, orientation is parallel to liquid flow

23
Types of Perforations
Fixed Valve Sulzer Chemtech

• SVG for fouling service


• HP MVG & MMVG, high capacity & low dry drop
• Fixed Valve 3 times stronger

Conclusions:
• If Size ↑, Capacity ↓ and Dry drop ↑

24
Types of Perforations
VG fixed Valve trays Sulzer Chemtech

25
Types of Perforations
MVG fixed Valve trays Sulzer Chemtech

26
Types of Perforations
Movable Mini Valve UFM Sulzer Chemtech

27
Types of Perforations
Movable Mini Valve UFM Sulzer Chemtech

 Tray panels equipped with UFM valves


Sulzer Chemtech

Valve Tray
Factors Sieve Tray Bubble-Cap Tray
Floating V-Grid
Capacity Moderate Moderately High Comparatively High Very High

Efficiency Low Moderately High High

Pressure Drop Moderate High Moderate Low


Comparatively less
Cost Low Costly Optimised or Less
costly
Maintenance Low Relatively High Moderate Low
High: Tends to collect
Fouling Tendency Low Moderate Low
Solids
Effects of
Low High Moderate Low
corrosion
Often used when Extremely low Liquid Where flexible Where high
Main Application turndown is not flow & where leakage operation is capacity is
critical must be minimized required. required.
Type of Liquid handling devices Sulzer Chemtech

30
Type of Liquid handling downcomers Sulzer Chemtech

31
Type of devices on active area Sulzer Chemtech

32
Type of devices on active area Sulzer Chemtech

33
Type of devices on active area Sulzer Chemtech

34
Type of devices on active area Sulzer Chemtech

35
Truncated downcommer Sulzer Chemtech

36
VG Plus Tray Sulzer Chemtech

VG Plus High Performance Tray

MVG valve High Performance


Downcomer

Re-Directing
Devise

37
VG Plus Tray Sulzer Chemtech

Redirecting and Froth Enhancer System

38
Types of Downcomer
Enhanced DC Sulzer Chemtech

StepArc: top view: normal chordal DC, bottom view: swept back
ModArc: top view: swept back, bottom view: sweptback
These two DCs applied to Side DC only

39
Step arc downcommer Sulzer Chemtech

40
Types of Downcomer
Enhanced DC ModArc Sulzer Chemtech

Red line: Extra bubbling area


ModArc Tray is a high capacity trays used whenever the Liquid load is high. The ModArc
geometry is applied only to side Down Comer.
The sizing of the once the Hydraulics is finalized the Dimension of ModArc has to be
designed in such a fashion that the area of the Down Comer Top after sizing the ModArc is
same as that mentioned in the Hydraulics the Sloped bottom Area is also matched in similar
fashion.
The design is advanced version of Sweptback. Normally whenever Swept back weir is
applied active area is lost but in ModArc Higher weir length is achieved without compromising
on the active area, hence it gives higher capacity.
41
High Performance Downcomers Sulzer Chemtech

 Conventional DC  High Performance


At DC At
Atdc Atdc

 High Performance Downcomers AS


allows for additional Active / Abdc
Abdc
Free area, and liquid handling FA = At - Abdc FA = At - AS

capacity
AA = At - Atdc- Abdc AA = At - Atdc- As

 Truncated DC  StepArc DC  ModArc DC


Lifted Deck
Sulzer Chemtech

 With the lifted tray deck, the panels do not rest flush with the support ring:
the spacers create a gap for vapor flow
 The gap converts the tray support ring dead area into active area
 The active area gain depends on tower diameter and number of flow paths:
 the lower the number of passes and the smaller the diameter, the higher is the
benefit

Spacer

Tray panel

Support Ring

Universal Clamp
e-VGPlus Tray Sulzer Chemtech

Push
valve

MVG or MMVG
valve

Lifted Deck

StepArc
downcomer

 In addition to the first generation enhancement features, i.e. Push Valves,


Baffle Bar, Stepped or Sloped Outlet Weirs, e-VGPlus trays have the
following booster:

“Lifted Deck technology”


Sulzer Chemtech

SPECIALITY TRAYS

- Dual flow trays

- Ripple Tray

- Baffle trays

- Cartridge Trays

- Channel Baffle Trays

- Horse shoe Trays

45
Specialty Trays
Dual Flow Sulzer Chemtech

No downcomer plus sieve hole


• Opening area up to 29%
• Higher capacity, lower efficiency, lower pressure drop
• Anti-fouling

46
Specialty Trays
Dual Flow Sulzer Chemtech

47
Sulzer Chemtech
Specialty Trays
Baffle Tray Sulzer Chemtech

Baffle trays
• Opening area: ~ 50%
• Highest Capacity, lower pressure drop, lower efficiency, anti-fouling

49
Specialty Trays
Baffle Tray Sulzer Chemtech

50
Specialty Trays
Baffle Tray Sulzer Chemtech

51
Specialty Trays
Cartridge Tray Sulzer Chemtech

• When ID (<800 mm) is small, installation & inspection impossible


• DC: enveloped, Support lug, Gasket or Seal ring, Dimensions: standardized

52
Specialty Trays
Cartridge Tray Sulzer Chemtech

Metallic
circlips
MOC:same
as tray

53
Specialty Trays
Cartridge Tray Sulzer Chemtech

54
Specialty Trays
Channel Baffle trays Sulzer Chemtech

55
Specialty Trays
Channel Tray Sulzer Chemtech

• When active area is too big, and efficiency could be a concern

56
Specialty Trays
Channel Tray Sulzer Chemtech

• When active area is too big, and efficiency could be a concern

57
Specialty Trays
Parallel flow- Horse Shoe, Pipe DC Sulzer Chemtech

• Pipe DC
• Central Baffle
• Inlet or OutWeir

58
Specialty Trays
Horse Shoe, Pipe DC or Reverse Flow Tray Sulzer Chemtech

Conditions to use:
• Upon Request eg. ABB's design / Caustic Tower Top Trays
• Very Low Weir Loading
• Very Low DC Velocity
• This Tray are normally designed with Bubble Cap,Notch Weir & Pipe
DC.

Outlet weir
Partition Baffle

Inlet weir

59
Specialty Trays
Horse Shoe, Pipe DC or Reverse Flow Tray Sulzer Chemtech

60
Sulzer Chemtech

SPECIALITY TRAYS PART-2

- High Capacity Multidown-commer

61
Specialty Trays
Multi down-commer Shell Tray Sulzer Chemtech

Shell Calming Section and Shell HiFi Plus

Longer Weir Length

Crown Inlet Device, up to 20% more capacity

62
Specialty Trays
Multi down-commer Shell Tray Sulzer Chemtech

63
Summary Sulzer Chemtech