SITE ANALYSIS
SITE BOUNDARIES TOPOGRAPHY OF THE SITE WIND DIRECTION ACCESSIBILITY SUN PATH ANALYSIS
The site is bounded by institutional The site has a relatively flat terrain The prevailing wind systems in the The site of the proposed project is The figure shows the Northern part
facilities, Bangko Sentral ng Pili- consisting low-lying areas rolling site are the Northeast monsoon adjacent to East Avenue and EDSA. of the site is the most shaded area
pinas (BSP) on the Northern part down to the northern portion of the (Amihan) which occurs from May to Measuring the distance, it is 13km and less humid, while on the So-
and Philippine Statistic Authority area. The elevation of the site ran- November, characterized by a lot of away from kilometer-zero (30mins- uthern part illustrates the higher
(PSA) on the Southern part. On the ges from 50-57 meters above sea rain (Rainy Season). And the South- -travel time). Public transportation temperature and humidity. This
Eastern part is the Social Securi- level. The northern portion of the west monsoon (habagat) which oc- like Jeepneys, Train, Shuttles, Tri- analysis will help the proponent to
ty System office (SSS) ,and on the site is started from 50 meters above curs from January to April, charac- cycle and pedicab are the primary identify the best orientation of the
Western part is the Philippine Post sea level, 57 meters above sea level terized by hot and humid weather, mode of transportation of Quezon structure, and positioning for natu-
Office Quezon City (PHILPOST). at the southern partition of the site. mostly hot period. City. ral lighting and ventilation.
SOIL PROFILE SITE BOUNDARIES WATER RUNOFF VEGETATION MAP SITE ELEVATION
The soil categorized as the Nova- The main source of noise is coming The surface drainage run-off pat- The site is located environment is The site belongs to 3% and below
liches Clay-Urban Land Complex from 3 adjacent road, which are tern which runs from northernmost filled with talahib grass almost the slope range. The range is very suita-
(NuvcCD) that is also known as ad- the NIA Road, BIR Road and East part towards the southernmost part whole site. Existing trees can also ble for the proposed development.
obe that is mainly characterized as Avenue. In term of the vistas, the of the site since it has the lowest be seen such as, Ipil-ipil trees, Sam-
compact and hard, making the site eastern portion has the most ple- point of elevation. paloc trees, Palm trees and Mango
much buildable. asant view, facing the other institu- Trees.
tional offices.
STRENGTH WEAKNESSES OPPORTUNITIES THREATHS
A good location surrounded by institutio- A good location surrounded by institutio- A good location surrounded by institutio- It is prone to privacy interruption and pro-
nal facilities, has abundant vegetation and nal facilities, has abundant vegetation and nal facilities, has abundant vegetation and ne to noise and air pollution. Reports on
surrounds by major and minor road for easy surrounds by major and minor road for easy surrounds by major and minor road for easy hold-up and snatching around the location
accessibility. accessibility. accessibility. is considered as a threat for future users of
the site.