3UA Thermally Delayed Overload Relays
CLASS 10
 Technical data according to IEC 947-4
 Type                                  3UA70 11/         3UA50/            3UA55          3UA58         3UA59         3UA60            3UA61/      3UA66         3UA68
                                       3UA70 21          3UA52                                                                         3UA62
 Trip class                            CLASS 10A (2 s < tA ≤10 s at 7.2 ×Ie from cold state and tA ≤2 min at 1.5 ×Ie from hot state)
 Phase failure sensitivity by          yes               yes               yes            yes           yes           yes              yes         yes           yes
 differential phase shift
 Changeover to automatic               no                yes               yes            yes           yes           yes              yes         yes           yes
 reset
 RESET button with trip-free           yes               yes               yes            yes           yes           yes              yes         yes           yes
 feature
 Temperature compensation              yes               yes               yes            yes           yes           yes              yes         yes           yes
 Switch position indicator             yes               yes               yes            yes           yes           yes              yes         yes           yes
 Test button actuates the NO           yes               yes               yes            yes           yes           yes              yes         yes           yes
             and NC contacts
 Terminal for contactor coil           no1)              yes               yes            no1)          no1)          no1)             no1)        no1)          no1)
 Permissible ambient
 temperature                    °C     –25 to +552)      –25 to +55
 Degree of protection                  IP 00/open or IP 20 to IEC 947-1 and DIN 40 050
 Shock resistance            g/ms      8/10
 Main circuit
 Rated insulation       AC/DC V        690               690               690            1000          690           1000             1000        1000          1000
 voltage Ui
 (pollution degree 3)
 Rated impulse                  kV     6                 6                 6              8             6             8                8           8             8
 withstand voltage Uimp
 Type of current,                      DC; AC up to 400 Hz                                                                                         AC 50 to 400 Hz
 frequency range
 Conductor cross-sections                                                                                                                          Setting
                                                                                                                                                   range
                                                                                                                                                   (≤200 A/
                                                                                                                                                   >200 A)
 Terminal screw                        M3                M4                M5             M5            M5            M6               M8          M 8/M 10      M 10
 solid or stranded            mm2      0.5 to 2.5        2.5 to 6          1.5 to 25      2.5 to 35     1.5 to 25     25 to 70         50 to 120   185/240       2 ×240
 finely stranded with end     mm2      0.5 to 1.5        1.5 to 4          1 to 16        1.5 to 25     1 to 16       25 to 50         25 to 95    –             –
 sleeve
 Flat bars                     mm      –                 –                 –              –             –             –                2 0× 3      2 0× 3/       2 ×30 ×5
                                                                                                                                                   2 ×30 ×5
 Tightening torque              Nm     0.4 to 0.7        1 to 1.5          2.5 to 3       2.5 to 3      2.5 to 3      6 to 8           10 to 14    10 to 14      14 to 24
                              lb. in   4 to 6.5          9 to 13           22 to 26.5     22 to 26.5    22 to 26.5    52 to 50         89 to 124   89 to 124/    124 to 210
                                Nm                                                                                                                 14 to 24
                              lb. in                                                                                                               124 to 210
 Power loss per
 conducting path (max.)
 at lowest value            W (VA)     0.6               0.9               1.2            2.6           0.8           5                5               4 ( 5)        6 ( 9)
 at highest value           W (VA)     2.3               2.25              3              4             2             7                7           10 (12)       15 (22)
 of the setting range
1) Not required.
2) The upper setting Io is to be reduced by 0.5% per
   1°C excess temperature or a min. space of
   5 mm is to be maintained between the units when
   several overload relays are series mounted and
   simultaneously operated at ambient temperatures
   exceeding 25 °C.
3UA Thermally Delayed Overload Relays
CLASS 10
 Technical data according to IEC 947-4
 Type                                  3UA70 11/                      3UA50/               3UA55             3UA58   3UA59                  3UA60           3UA61/        3UA66       3UA68
                                       3UA70 21                       3UA52                                                                                 3UA62
 Auxiliary circuit
 Auxiliary contacts                    1 NO + 1 NC                    1 NO + 1 NC                                    1 NO + 1 NC
 Conductor cross-sections
 Terminal screw                        M3                             M 3.5
 solid or stranded         mm2         2×(0.5 to 2.5)                 2 ×(0.5 to 1)/2× (1 to 2.5)
 finely stranded with end  mm2         2×(0.5 to 1.5)                 2 ×(0.5 to 1)/2× (0.75 to 2.5)
 sleeve
 Tightening torque          Nm         0.4 to 0.7                     0.8 to 1.4
                          lb. in       4 to 6.5                       7 to 12
 Rated insulation voltage Ui           NC                                                  Unequal potential                                                Equal potential
                                                     NS1-5329
                                                                                                                     NS1-5330
                                                                                                                                                                                  NS1-5331
 (pollution degree 3)                                                                      (NO + NC)                                                        (NO + NC
                                                                                                                                                            connected as
                                                                                                                                                            changeover contact)
                                  V    690                                                 400                                                              690
 Rated impulse
 withstand voltage Uimp          kV    6
 Switching capacity                    at AC-15:                                                                     at DC-13:
 Rated operational
 voltage Ue                       V    24       60              125      230       400     500     690               24              60     110     220
 Rated operational
 current Ie                       A        2     1.5              1.25      1.15     1.1     1         0.8                  2         0.5     0.3     0.2
 Conventional thermal
 current Ith                      A        6
 Short-circuit protection              Fuses LV HRC Type 3NA, DIAZED Type 5SA/5SB, NEOZED Type 5SE: utilization category gL/gG 6 A
                                       Miniature circuit-breaker (C characteristic): 3 A
 a -, u -, r   -Ratings, main circuit
 Rated current                   A     12                             14.5 (25)1)          45                88      63                     135             150/180       400         630
 Rated voltage                AC V     600                            600                  600               600     600                    600             600           600         600
 a -, u -, r   -Ratings, auxiliary circuit
 Rated voltage                AC V     600, >150 same polarity
 Switching capacity                    B 600, R 300
 Adapter for installing the relay as a single unit
 Type                                  3UX1 418                                            3UX1 420                  3UX1 421                               3UX1 424                  3UX1 425
 For overload relay                    3UA50                                               3UA52                     3UA58                                  3UA60                     3UA55
 Conductor cross-sections
 Terminal screw                        M 3.5                                               M4                        M6                                     M6                        M5
 solid or stranded        mm2          1 to 4                                              2.5 to 10                 2.5 to 35                              2×25 to 70                1 to 25
 finely stranded with end
 sleeve                   mm2          0.75 to 2.5                                         1.5 to 6                  1.5 to 25                              2×25 to 50                1 to 16
Trip classes of thermal, delayed                                                           Trip class                Tripping time tA in seconds
magnetic or solid-state overload relays –                                                  A                         at 7.2 ×Ie from cold state
Excerpt from IEC 947-4                                                                     10                        2<         tA   ≤ 10
                                                                                           10                        4<         tA   ≤ 10
                                                                                           20                        6<         tA   ≤ 20
                                                                                           30                        9<         tA   ≤ 30
1) Value in brackets only valid for 3UA52.
3UA Thermally Delayed Overload Relays
CLASS 10
Technical data according to IEC 947-4 and DIN VDE 0660 Part 102
Short circuit protection with fuses for motor feeders with short-circuit currents up to 50 kA at 690 V1), 50/60 Hz
Overload       Permissible short-circuit fuses for motor starters                                               Short-circuit protection with circuit
relay          consisting of overload relay and contactor, contactor assembly
Type                                                                                                            breakers, fuseless motor feeders,
               Fuse links                                                                                       combination of devices for mounting
               LV HRC               Type 3NA     LV HRC                  British                   u -listed
               DIAZED               Type 5SB     Type 3ND                standards                 fuses        onto busbars, see "Circuit breakers"
               NEOZED               Type 5SE     Utilization             fuses                     CLASS        and "Fuseless load feeders".
               Utilization category              category aM             BS 88 Type T              R K5
               gL/gG
Setting        Type of coordination2)            Type of coordination2) Type of coordination2)
range          “1”                “2”            “2”                    “1”                “2”
A              A                  A              A                      A                  A       A
3UA70 21
 0.1 – 0.16    25                  0.5 slow3)    –                         25              –        1
 0.16– 0.25    25                  13)                                     25                       1
 0.25– 0.4     25                  1.63)                                   25                       2
 0.4 – 0.63    25                  2             –                         25                  2    3
 0.63– 1       25                  4                                       25                  4    5
 0.8 – 1.25    25                  4                                       25                  4    6
 1 – 1.6       25                  6             –                         25               6       8
 1.25– 2       25                  6                                       25               6      10
 1.6 – 2.5     25                  6                                       25              10      12
 2 – 3.2       25                 10             –                         25              10      12
 2.5 – 4       25                 10                                       25              10      12
 3.2 – 5       25                 10                                       25              10      12
 4 – 6.3       25                 10             –                         25              10      15
 5 – 8         25                 10                                       25              10      20
 6.3 –10       25                 10                                       25              10      20
3UA50
 0.1 – 0.16    35                  0.5 slow3)    –                         25              –        1
 0.16– 0.25    35                  13)                                     25                       1
 0.25– 0.4     35                  1.63)                                   25                       2
 0.4 – 0.63    35                  2             –                         25                  2    3
 0.63– 1       35                  4                                       25                  4    5
 0.8 – 1.25    35                  4                                       25                  4    6
 1 – 1.6       35                  6             –                         25               6       8
 1.25– 2       35                  6                                       25               6      10
 1.6 – 2.5     35                  6                                       25              10      12
 2 – 3.2       35                 10             –                         25              10      12
 2.5 – 4       35                 10                                       25              10      12
 3.2 – 5       35                 16                                       25              16      12
 4 – 6.3       35                 16             –                         25              16      15
 5 – 8         35                 20                                       25              16      20
 6.3 –10       35                 25                                       25              20      20
 8     –12.5   35                 25             –                         25              20      20
10     –14.5   35                 25                                       35              32      20
3UA52
 0.1 – 0.16    63                  0.5 slow3)    –                         63              –        1
 0.16– 0.25    63                  13)                                     63                       1
 0.25– 0.4     63                  1.63)                                   63                       2
 0.4 – 0.63    63                  2             –                         63                  2    3
 0.63– 1       63                  4                                       63                  4    5
 0.8 – 1.25    63                  4                                       63                  4    6
 1 – 1.6       63                  6             –                         63               6       8
 1.25– 2       63                  6                                       63               6      10
 1.6 – 2.5     63                  6                                       63              10      12
 2 – 3.2       63                 10             –                         63              10      12
 2.5 – 4       63                 10                                       63              10      12
 3.2 – 5       63                 16                                       63              16      12
 4 – 6.3       63                 16             –                         63              16      15
 5 – 8         63                 20                                       63              20      20
 6.3 –10       63                 25                                       63              20      20
 8     –12.5   63                 25             16                        63              20      30
10     –16     63                 25             20                        63              25      30
12.5   –20     63                 25             20                        63              35      30
16     –25     63                 25             20                        63              35      45
3UA55
 1 – 1.6       80                  6             –                       100                6       8
 1.25– 2       80                  6                                     100                6      10          1) Voltage tolerance +5%.
 1.6 – 2.5     80                  6                                     100               10      12          2) Coordination of short-circuit equipment
 2 – 3.2       80                 10             –                       100               10      12             according to IEC 947-4/DIN VDE 0660
 2.5 – 4       80                 10                                     100               10      12             Part 102:
 3.2 – 5       80                 16                                     100               16      15             Type of coordination “1”:
 4 – 6.3       80                 16             –                       100               16      15             The contactor or starter must not endanger
 5 – 8         80                 20                                     100               20      20             persons or the installation in the event of a
 6.3 –10       80                 25                                     100               25      25             short-circuit. They do not need to be suitable
                                                                                                                  for further operation without repair and the
 8 –12.5       80                 25             16                      100               20      25             renewal of parts.
10 –16         80                 35             20                      100               40      40
12.5 –20       80                 50             20                      100               50      50             Type of coordination “2”:
                                                                                                                  The contactor or starter must not endanger
16     –25     80                 50             40                      100               63      60             persons or the installation and must be
20     –32     80                 80             50                      100               80      60             suitable for further use.There is a danger
25     –36     80                 80             50                      100               80      60             of contact welding.
32     –40     80                 80             50                      100               80      60          3) D-fuse links UN = 500 V, make SIBA.
36     –45     80                 80             50                      100               80      60
3UA Thermally Delayed Overload Relays
CLASS 10
Technical data according to IEC 947-4 and DIN VDE 0660 Part 102
Short-circuit protection with fuses for motor feeders with short-circuit currents up to 50 kA at 690 V1), 50/60 Hz
Overload           Permissible short-circuit fuses for motor starters                                                 Short-circuit protection with circuit
relay              consisting of overload relay and contactor, contactor assembly
Type                                                                                                                  breakers, fuseless motor feeders,
                   Fuse links                                                                                         combination of devices for mounting
                   LV HRC               Type 3NA      LV HRC                 British                     u -listed
                   DIAZED               Type 5SB      Type 3ND               standards                   fuses        onto busbars, see "Circuit breakers"
                   NEOZED               Type 5SE      Utilization category   fuses                       CLASS        and "Fuseless load feeders".
                   Utilization category               aM                     BS 88 Type T                R K5
                   gL/gG
Setting            Type of coordination3)             Type of coordination3) Type of coordination3)
range              “1”                “2”             “2”                    “1”                “2”
A                  A                  A               A                      A                  A        A
3UA58
 16   –    25      160                 50              25                      160                  63       60
 20   –    32      160                 63              35                      160                  63       70
 25   –    40      160                 80              40                      160                  80       70
 32   –    50      160                125              50                      160                  80       70
 40   –    57      160                125              63                      160              100        70
 50   –    63      160                125              63                      160              100       100
 57   –    70      160                125              63                      160              100       125
 63   –    80      250                160              80                      160              125       150
 70   –    88      250                160             100                      160              125       175
3UA70 11, 3UA59
  0.1 –     0.16    25                   0.5 slow4)    –                        25              –            1
  0.16–     0.25    25                   14)                                    25                           1
  0.25–     0.4     25                   1.64)                                  25                           2
  0.4 –     0.63    25                   2             –                        25                   2        3
  0.63–     1       25                   4                                      25                   4        5
  0.8 –     1.25    25                   4                                      25                   4        6
  1 –       1.6     25                   6             –                        25                   6        8
  1.25–     2       25                   6                                      25                   6       10
  1.6 –     2.5     25                   6                                      25                  10       12
  2 –       3.2     25                 10              –                        25                  10       12
  2.5 –     4       25                 10                                       25                  10       12
  3.2 –     5       25                 10                                       25                  16       12
  4 – 6.3           25                 10              –                        25                  16       15
  5 – 8             25                 10                                       35                  16       20
  6.3 – 10          25                 10                                       35                  20       20
  8 – 12.52)        35                 16              –                        63                  32       20
 10 – 16            63                 25              16                       63                  32       30
 12.5 – 20          63                 25              20                       63                  35       45
 16   – 25          63                 25              25                       80                  50       45
 20   – 32          80                 63              35                       80                  63       60
 25   – 40         125                 80              40                      160                  80       70
 32   – 45         160                100              50                      160               80        70
 40   – 57         160                125              63                      160              100       100
 50   – 63         160                125              63                      160              100       100
3UA60, 3UA61, 3UA62
 55   – 80          250               160              80                      160              125       150
 63   – 90          250               160             100                      160              125       150
 80   –110          400               200             125                      315              160       175
 90   –120          400               224             125                      315              200       175
110   –135          400               224             160                      315              200       175
120   –150          400               250             160                      315              200       200
135   –160          400               250             160                      355              250       200
150   –180          400               250             200                      355              250       200
3UA66, 3UA68
                                                                                                                     1) Voltage tolerance +5%.
 80   –125          355               224             125                      355              224       300
                                                                                                                     2) For 3UA70 11 setting range 8 to 12 A.
125   –200          355               224             200                      355              224       300
                                                                                                                     3) Coordination of short-circuit equipment
160   –250          500               400             250                      500              355       300           according to IEC 947-4/DIN VDE 0660
                                                                                                                        Part 102:
200   –320          500               400             315                      500              400       300           Type of coordination “1”:
250   –400          800               500             400                      800              450       400           The contactor or starter must not endanger
                                                                                                                        persons or the installation in the event of a
320   –500          800               500             630                      800              500       400           short-circuit. They do not need to be suitable
                                                                                                                        for further operation without repair and the
400   –630         1000               500             630                    1000               500      1200           renewal of parts.
                                      (630)5)                                                            CLASS L        Type of coordination “2”:
                                                                                                                        The contactor or starter must not endanger
                                                                                                                        persons or the installation and must be
                                                                                                                        suitable for further use.There is a danger
                                                                                                                        of contact welding.
                                                                                                                     4) D-fuse links UN = 500 V, make SIBA.
                                                                                                                     5) Valid for 3TB contactor.