0% found this document useful (0 votes)
169 views2 pages

Advanced Meter for Utility Companies

The document provides information on the Mk6N advanced three phase electronic revenue meter. The Mk6N updates the design and firmware of the original Mk6 meter to address new IEC standards and incorporate an updated power supply and input protection technology. Key features of the Mk6N include being AMI ready, having high accuracy, large data storage, a large LCD display, the ability to measure everything, being upgradeable, having anti-tamper capabilities, and supporting script extensions.

Uploaded by

freddysh4330
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views2 pages

Advanced Meter for Utility Companies

The document provides information on the Mk6N advanced three phase electronic revenue meter. The Mk6N updates the design and firmware of the original Mk6 meter to address new IEC standards and incorporate an updated power supply and input protection technology. Key features of the Mk6N include being AMI ready, having high accuracy, large data storage, a large LCD display, the ability to measure everything, being upgradeable, having anti-tamper capabilities, and supporting script extensions.

Uploaded by

freddysh4330
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Mk6N

Advanced Three Phase


Electronic Revenue Meter
Genius Series - Class 0.5S and Class 1 and 2

PRODUCT INFORMATION

Utilizing the same advanced meter design and


firmware platform as the original Mk6, the new Mk6N
meter updates this platform to address new IEC
standards and to incorporate an updated power
supply and input protection technology utilized by our
latest range of energy meters.

KEY FEATURES

AMI READY HIGH LARGE LARGE MEASURE UPGRADEABLE ANTI SCRIPT


ACCURACY DATA STORAGE LCD DISPLAY EVERYTHING TAMPER EXTENSIONS
Mk6N Genius Series - Class 0.5S and Class 1 and 2

Advanced Three Phase


Electronic Revenue Meter
SPECIFICATIONS

Accuracy Communications Options Time Clock Equipment Failure


• Class 0.5S , Class 1 and Class 2 • ANSI Type 2 Optical Port (ANSI • Accuracy (internal) within 30 seconds Alarms (EFAs)
• IEC62052-11, IEC62053-21 (Class 1), C12.18) or IEC 62056-21 (IEC 61107) per month A single user defined alarm condition
IEC62053-22 (Class 0.5S), Optical FLAG Port • Backup time of 2 years without power (via extensions) is available plus
IEC62053-23 (Class 2) • RS232 (RTS/CTS and DTR/DCD) • Backup utilizing either lithium battery pre-programmed alarms based
• RS485 (2 or 4 wire multidrop) or optional SuperCap on numerous:
Measurement Modes •Mains synchronised or internal crystal • Self-Checks
• SCADA
• Single Phase (3 Circuits) time keeping. Mains synchronised • Tamper and wiring checks
• Modems (PSTN/GPRS/GSM/C DMA)
• 3 Phase 3 Wire reverts to internal crystal on loss of
• Internal Modem Power Supply These Alarms Can:
• 3 Phase 4 Wire voltage on all phases
• MV-9OTM Compatible • Turn on LED, LCD indicator or relay
Measured Energy Values • PPP / GPRS Data Storage output
• 3 Elements, 4 Quadrants • MODBUS (Configuration, TOU Data and Load • Record an event in the event log
• Import/Export Wh, varh and VAh • Master / Slave arrangement with up to Survey Data) • Trigger an event such as a remote
• Absolute Wh, varh and VAh 31 ‘Slave’ meters accessed through • FlashRAM alarm, dial an emergency number,
one ‘Master’ gateway meter • Battery backed up RAM send an SMS to a programmable
• Phase A, B, C or Total
number or send alarm messages via
Voltage Sag / Swell
Other Measured and GPRS to a programmable server
Displayed Values • Operating Range of 57V to 240V • 5 Cycle Resolution
(phase to neutral) Extensions for
• W, var, VA • Records time / date / phase / duration
• Burden of < 10VA per phase @ Vn Customer Applications
• True RMS Voltage (3 Phase) and worst excursion
(3 Phase) • Programmable trigger levels The Mk6N inherits the ability to use
• True RMS Current (3 Phase) Extensions to increase the functionality
• Frequency of 45 to 65Hz
• Power Factor LCD Display of the standard metering platform. A
• Frequency Current simple yet powerful scripting language
•16 Character by 2 line
• Phasor Angles • CT Range of 1/1.2A, 5/6A, 1/4A alphanumeric display allows complex register manipulations
and 5/20A to be performed that can create
Load Survey / Load Profile •Programmable units, multipliers and
•WC Range of 10/100A customized functions within the
leading zeros
• NEM Compliant (Class 1 Only) meter without the need for a firmware
• Up to 64 user definable upgrade. EDMI is always developing
•Standard 400 day-channel capacity at •Short time over-current of 20 times screen displays new extensions and we offer custom
30 minute intervals ‘max for 0.5 seconds • Displays any available extension creation for specific customer
• Optional additional storage to increase • Burden of less than 0.5VA meter parameter needs. Contact us to find out more
to over 2,500 day-channel capacity at per phase about Extensions for the Genius range
30 minute intervals Optional Functions of meters
• Up to 50 Channels Auxiliary Supply Options
• Quality of Supply (QOS) features
• Per survey interval programmable from •240V, 110V Aux Only (other voltages • Waveform Capture
Examples of currently available
1 second to 1 month available on special order) Extensions for EDMI Genius
• Harmonic analysis to the Energy Meters:
• Multiple independent surveys Pulsing Inputs / Outputs 50th harmonic
• Energy, instantaneous readings and • Send SMS at percentage of
•Maximum of 8 I/O with up to 8 outputs • THD Measurement
pulsing inputs as potential survey maximum demand
(2 standard) or 6 inputs • Fundamental energy measurement
channel sources • Average power factor for billing period
• Output voltage - 5 - 220V DC, Software • LCD menu system
• Ability to store average / minimum /
12 - 240V AC
maximum values over interval duration • EDMI EziView software available for • Magnetic tamper detection
for individual channels • Output current of 0.1A maximum
programming and reading of meter • Power factor control extension
• Output pulse width 2 output (Runs on Windows 98/ME/NT/
Time of Use • Maximum demand control of loads via
independent LEDs of lms to 250ms 2000/XP) pulsing outputs
• 8 rates plus unified rate • Programmable output polarity • EziView also allows offline • Average voltage / current / unbalance,
• Up to 12 separate import and • Input Voltages of 5, 12, 48, 110, 240V configuration of tariff programs and THD etc.
export registers AC / DC all meter parameters, for later upload • Voltage Sag / Swell or Power Outage
•Up to 200 programmable • Time synchronised (optional) to meters
• Voltage Quality
special days
Environmental Dimensions • Send SMS / GPRS Alarm on
•Daily, Weekly, Monthly, Yearly, Special
• Operating Range of -10 to +60°C Equipment Failure Alarm
• 13 or more previous periods • 292.5mm (L) x 175mm (W) x 94mm (D)
• Storage Range of -40 to +85°C • Detect Individual Phase VT Failures
• Block or Rolling Maximum Demand
• Time of Maximum Demand
• Configurable Billing Reset Button

EDMI Limited
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 | Fax: +65 6756 0125
Email: sgmarketing@edmi-meters.com | sgtechsupport@edmi-meters.com www.edmi-meters.com

Copyright © 2014 EDMI Limited. All Rights Reserved. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.

You might also like