0% found this document useful (0 votes)
317 views2 pages

Powerfit 50 - 60Hz 3P Charger

The document summarizes a microprocessor-controlled battery charger called the POWERFIT CHARGER. It is available with either 400/230V three-phase or 230V single-phase input models. The charger is suited for recharging lead-acid traction batteries with recharge times as low as 8 hours, making it suitable for multi-shift operations. It has various charging modes including pre-charging, bulk charging, proportional charging, equalizing, and maintenance charging that are controlled and monitored by the microprocessor. It also has safety features like overcharge protection, thermal cut-off, and phase failure detection.

Uploaded by

suranga yapa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
317 views2 pages

Powerfit 50 - 60Hz 3P Charger

The document summarizes a microprocessor-controlled battery charger called the POWERFIT CHARGER. It is available with either 400/230V three-phase or 230V single-phase input models. The charger is suited for recharging lead-acid traction batteries with recharge times as low as 8 hours, making it suitable for multi-shift operations. It has various charging modes including pre-charging, bulk charging, proportional charging, equalizing, and maintenance charging that are controlled and monitored by the microprocessor. It also has safety features like overcharge protection, thermal cut-off, and phase failure detection.

Uploaded by

suranga yapa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

POWERFIT BATTERY CHARGER

MICROPROCESSOR CONTROLLED CHARGER

FOR TRACTION BATTERIES


The POWERFIT CHARGER is available as 400/230V,

50/60 Hz, three phase input model and 230V, 50/60

Hz, single phase input model. The unit is suited to the

recharging needs of lead acid traction batteries.

TECHNICAL SPECIFICATIONS
• WA charging mode, in compliance with curve DIN 41774
• recharge time as low as 8 hours, making it suitable for multishift operations, and up to 12 h for overnight charging
• start delay: diagnostics check for correct battery and state of battery
• pre-charging mode (1h); detection system ensuring prevention of overcharging and charge inhibit for excessively
overdischarged batteries
• desulphating charge
• proportional Charge
• pulsed equalising mode
• maintenance charge
• microprocessor controlled and multi-voltage pc board
• charging progress display
• all stages are monitored and covered by security systems
• reliability and quality gained from years of design experience
• thermal cut-out & security timer (13 h) MALAYSIA

EnergyHub (M) Sdn Bhd (1105004-H) EnergyHub (PG) Sdn Bhd (1243460-D) EnergyHub Battery Sdn Bhd (1315434-V)
No.17 Jalan Sungai Jeluh 32/192 No.17, Lorong Perda Timur 7, Bandar Perda, No. 16, Jalan Perniagaan Setia 4, Taman Perniagaan Setia,
Kawasan Perindustrian Kemuning 14000 Bukit Mertajam, Penang, Malaysia. 81100 Johor Bahru, Johor, Malaysia.
Seksyen 32, 40460 Shah Alam Tel: 604-548 3313 Fax : 604-548 4312 Tel: +607 - 562 8368 / 562 7338 / 562 7336
Selangor Darul Ehsan, Malaysia. Email: salespg@energyhub.com.my Fax: +607 - 562 3088
Tel: 603-5525 1900 Fax: 603-5525 5800 Email: salesjb@energyhub.com.my
Email: salesmp@energyhub.com.my
Output Battery Capacity Current Input Weight Charger Cabinet
voltage 10-12 h recharge (A) voltage (Kg) type
(V) time (Ah) (Vac)
24 345÷420 60 3x400 39 24/60 A2
24 440÷560 80 3x400 44 24/80 A2
24 565÷700 100 3x400 47 24/100 A2
24 690÷840 120 3x400 52 24/120 A2
24 810÷980 140 3x400 56 24/140 A2
CHARGE PATTERN 24 880÷1120 160 3x400 57 24/160 A2
• Pre-Charging: preventing overcharging of fully charged 24 1010÷1260 180 3x400 68 24/180 A2
batteries and inhibit charge for over discharged batteries.
36 345÷420 60 3x400 50 36/60 A2
• Bulk charge: battery is charged until the gassing voltage
(2,40 VPC). 36 440÷560 80 3x400 50 36/80 A2
• Proportional Charge: gassing charged duration governed 36 565÷700 100 3x400 51 36/100 A2
by Bulk charge duration, to compensate for the degree of
discharge. 36 690÷840 120 3x400 57 36/120 A2
• Equalising: bringing all cells to a fully charged condition; 36 810÷980 140 3x400 60 36/140 A2
equalising mode will follow the end of charge.
36 880÷1120 160 3x400 65 36/160 A2
• Maintenance Charge: maintaining the battery in a fully
charged condition when it is stood out of service. 36 1010÷1260 180 3x400 65 36/180 A2
48 345÷420 60 3x400 50 48/60 A2
PROTECTIONS
Off switch: the unit is automatically switched off by pushing the 48 440÷560 80 3x400 52 48/80 A2
button. Charging cannot be resumed. 48 565÷700 100 3x400 56 48/100 A2
Overall charge time: 13h charging if charger sequence
48 690÷840 120 3x400 61 48/120 A2
malfunctions. Malfunction of charging sequence is indicated by
illumination of a red diode. 48 810÷980 140 3x400 67 48/140 A2
POWERFIT is protected against faults or incorrect battery 48 880÷1120 160 3x400 85 48/160 A2
connection. The unit incorporates a self-diagnostic system in the
48 1010÷1260 180 3x400 91 48/180 A2
event of the following:
• overdischarged battery detection 48 1100÷1400 200 3x400 99 48/200 A1
• battery disconnect shutdown 72 345-420 60 3x400 61 72/60 A2
• thermal cut-out
72 440-560 80 3x400 65 72/80 A2
• maintenance charge shutdown
• phase failure detection 72 565-700 100 3x400 71 72/100 A2
72 690÷840 120 3x400 78 72/120 A2
DISPLAY 72 810÷980 140 3x400 90 72/140 A1
80 345-420 60 3x400 66 80/60 A2
80 440-560 80 3x400 68 80/80 A2
80 565-700 100 3x400 79 80/100 A2
80 690÷840 120 3x400 86 80/120 A2
80 810÷980 140 3x400 95 80/140 A1
80 880÷1120 160 3x400 109 80/160 A1
80 1010÷1260 180 3x400 109 80/180 A2
96 275÷350 50 3x400 65 96/50 A2
1 96 345÷420 60 3x400 76 96/60 A2
2 96 440÷560 80 3x400 88 96/80 A2
4 96 565÷700 100 3x400 95 96/100 A1
3
96 690÷840 120 3x400 100 96/120 A1

1 . YELLOW LED: battery connected / charge on


HEIGHT WIDTH DEPTH
2 . GREEN LED: equalising / maintenance charge TYPE
3 . RED LED: error
(H . mm) (W . mm) (D . mm)
4 . FIVE LED’S INDICATE BATTERY VOLTAGE OR
A1 900 500 400
STATE OF CHARGE
A2 760 500 400
02/2021
printstudiografico 339 3098824

Energyhub Asia Pte Ltd


11 Benoi Place
Singapore 629931
ASIA Tel/Fax: +65 6513 8878
Email: info@energyhubasia.com.sg