0% found this document useful (0 votes)
204 views2 pages

Polycoat RTL

This document provides information on Polycoat, a bitumen emulsion paint used as a vapor barrier on concrete structures. It can be applied by roller, brush or spray between 5-55°C and dries to form a flexible, black protective film. Polycoat does not require priming on concrete and provides protection from vapor transmission, chlorides, sulfates and fungi while being water-based, economical and versatile.

Uploaded by

niaz05288
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
204 views2 pages

Polycoat RTL

This document provides information on Polycoat, a bitumen emulsion paint used as a vapor barrier on concrete structures. It can be applied by roller, brush or spray between 5-55°C and dries to form a flexible, black protective film. Polycoat does not require priming on concrete and provides protection from vapor transmission, chlorides, sulfates and fungi while being water-based, economical and versatile.

Uploaded by

niaz05288
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Polycoat

Bitumen emulsion paint


Emulsified thixotropic flexible protective barrier to vapor transmission.

characteristics
► Resists the attack of salts like chlorides and sulphates
that are present in the soil
► Easy to apply
► Cold applied
► Adheres to concrete, metal, wood, cork, etc.
► Can be applied in closed or confined spaces

TDS_Polycoat_GCC_RTL_0619
► Water-based
► Versatile
► Anti-fungal
► Economical

DESCRIPTION 1
Polycoat is an emulsified thixotropic bitumen protective
coating. The coating dries to form a black flexible Priming
protective film. The finished film forms a tough barrier to Polycoat doesn't require priming and can directly be
vapor transmission. applied on to concrete surface. Incase highly porous
surface, a priming coat may be applied to seal the pores
Fields of application and stabilize the surface by diluting the same bitumen
Polycoat is used for providing damproofing for below emulsion with 20% water. Apply the primer coated at
ground concrete structures which are above the water approx. 4m2/L allows to dry.
table. This can also be used as the protective coating for Application
built-up roofing systems and other exposed surfaces. The Stir the contents of the drum thoroughly prior to application
coating is also used as a moisture vapor barrier on block to remove any sediment. The application can be done
works and concrete surfaces. with a roller, brush or suitable industrial spray. Apply the
Application instructions coating at a coverage rate of 1-4 m2/L/coat, depending
The application temperature should be between 5°C to 55°C. on the dry film thickness required. For highly demanding
Application procedures may vary slightly depending upon situations, it is recommended to apply in multiple coats.
site conditions. The general recommended guidelines for the Further coats shall be applied only after the previous coat
application of the bitumen coating is as follows: dries off completely. However, the coverage depends on the
smoothness and porosity of the substrate and the required
Surface preparation thickness of the coating.
The surface shall be cleaned thoroughly of all contaminants
like dust, traces of curing compound, oil and grease. All Protection
surface imperfections and protrusions are to be removed The coating shall be protected from ongoing site activities
and repaired. Structurally unsound and friable concrete and during backfilling from getting damaged by a 150
must be removed and repaired with a suitable Polycrete* micron polyethylene sheet.
concrete repair mortar.
Coverage technical specification
Average wet film thickness of 250 microns achieved when
properties valueS TEST
applied @4m2/L/coats, at required number of coats
STANDARDS
storage & shelf life Form Thick -
The drums and pails must be stored in a covered area, viscous
away from direct sunlight, UV and other sources of liquid
heat. The shelf life is up to 12 months when stored as Color dark -
per recommendations. Excessive exposure to sunlight, brown
UV and other sources of heat will result in considerable Density, [g/cc] 1.05 ±0.05 astm d 2939
deterioration of the product and reduce its shelf life.
Solid content, [%] 18±2 astm d 2939
health & safety Firm set, [hours] 24 astm d 2939
Protective clothing such as gloves and goggles should be Application
worn when handling the product. Treat any splashes to the temperature, [°C] 5 to 55 -
skin or eyes with fresh water immediately. Should any of the
Service temp, [°C] -­5 to 75 -
products be accidental swallowed, do not induce vomiting,
but call for medical assistance immediately. Ensure that the VOC [g/l] <50 ASTMD3960/
container is available for medical attendant to examine any D2369
relevant instructions and content details. All values given are subject to 5-10% tolerance
supply
Apart from the information given here it is also important to observe the relevant
Polycoat 16L pail guidelines and regulations of various organisations and trade associations as
well as the respective standards. The aforementioned characteristics are based
TDS_Polycoat_GCC_RTL_0619

on practical experience and applied testing. Warranted properties and possible


uses which go beyond those warranted in this information sheet require our
written confirmation. All data given was obtained at an ambient and material
temperature of +23°C and 50 % relative air humidity at laboratory conditions
unless specified otherwise. Please note that under other climatic conditions
hardening can be accelerated or delayed.
The information contained herein, particularly recommendations for the
handling and use of our products, is based on our professional experience.
As materials and conditions may vary with each intended application, and
thus are beyond our sphere of influence, we strongly recommend that in each
case sufficient tests are conducted to check the suitability of our products
for their intended use. Legal liability cannot be accepted on the basis of the
contents of this data sheet or any verbal advice given, unless there is a case
of wilful misconduct or gross negligence on our part. This technical data sheet
2 supersedes all previous editions relevant to this product.

Henkel Polybit Industries Ltd.; PO Box: 293, Umm Al Quwain, UAE


Tel:+971(6)76 70 777; Fax:+971(6)76 70 197; henkelpolybit@henkel.com
Henkel Polybit Industries Ltd.; PO Box: 5911, Dammam-31432, KSA
Tel:+96613808 4061 / 62, Fax: +966 13 812 1164; polybitdammam@henkel.com
www.henkelpolybit.com