A PROJECT REPORT ON TYTPICAL
CIRCUIT ARRANGEMENT FOR SURFACE
     WIRING (CASING &CAPPING)
  NAME                         SUBHASISH SARKAR
  ROLL NO.                            27
  YEAR                               2023
                        CERTIFICATE COURSE ON ELECTRICAL
  COURSE NAME             INSTALLATION, MAINTENANCE,
                          REPAIRING & SAFETY PRACTICES
  NAME OF INSTITUTION         JADAVPUR UNIVERSITY
           INTRODUCTION
Electricity is the vital source to energy in the 21st century. Human cannot
wait for a minute without electricity. So, for lighting, and driving different
appliances electricity connection is more important for future
perspective. Wiring is important for smooth connection of supply with
load. Wiring is done different method.
       Different wiring methods are:
           1)   Cleat Wiring (Temporary wiring)
           2)   Batten Wiring
           3)   Casing -Capping Wiring (Wood, PVC)
           4)   Conduit Wiring (PVC, Rigid PVC, Metal)
           5)   Concealed Wiring (Metal, PVC).
           6)   Hybrid Wiring (Mix of above methods)
       Factors affecting the choice of wiring:
          1. Durability
          2. Safety
          3. Appearance
          4. Cost
          5. Accessibility
          6. Maintenance.
  From fire safety point of view, concealed wiring is found best with
  joint-less method of connection. External fire cannot damage the
  wiring, and provide light for safe escape, and in case of electrical
  short-circuit, the fire arrested within wall, and cannot produce external
  fire.
                    Here we discuss with the Casing -Capping Wiring
 Note :
     1. Either 800 watt or 10 points, whichever is less, would be connected from
        each single way from Distribution Box (DB).
     2. For future extension of load provision should be kept for either 20%
        excess of total watt or sufficient excess points.
 Circuit Diagram:
             Call
             Bell
                                                                  SPNDB
                     Bulb        Ceiling Fan
                                                              Main Switch
                     Bell Push
Plug Board
                                                                            Earth Bus
                                               Switch Board
List of materials with Specification:
 Sl.   Name of Materials      Specification with Quantity
 No
   1. SPNDB                   2 way, MCB DB, with 2 nos.
                              of 20A SPMCB in 175 x 85 x
                              50 mm PVC box.
   2. Casing & Capping        20mm - 6 mts, No corners,
                              bends used.
   3. Main Switch             32A Double pole, Sheet
                              metal enclosure type.
   4. MS Screw                20/3- 36 nos.
                              25/5- 8 nos.
                              35/8- 6 nos.
   5. Flat Washer             48 Nos
   6. PVC insulated copper    Red – 10 Mts
      wire                    Green - 10 Mts
                              Black - 10 Mts
   7.   PVC tape              20 mm 9 mts roll – 1 NO
   8.   Piano Switch          250 volt, 5A – 3 Nos
   9.   Plug Socket           250V, 5pin , 5A – 1 No
  10.   Bell Push Switch      250V, 5A – 1 No
  11.   Earth Bus             25 x 6 mm GI earth bus – 4
                              hole
  12. Calling Bell            250 volt ding dong bell
  13. Inspection Box / Join   175 x 85 x 50 mm PVC box –
      Box                     1 No
  14. Fuse                    250 Volt 20A – 1 No
  15. Bulb Holder             250 Volt BC type batten
                              holder – 1 No
List of Tools with specification:
 Sl.      Name of Tools     Specification with quantity
 No
  1.   Combination Plier   Drop forged insulated handle,
                           8”-1 No
  2.   Long Nose plier     6” long nose plier – 1 No
  3.   Screw Driver        6” 6mm slot head-1 No
                           8” 8mm sloted & Philips head
                           combo – 1 no
  4.   Live Line Tester    90v or above neon tester with
                           1MΩ resistance -1 No
  5.   Poker               Triangle, 6” wooden handel-1
                           no
  6.   Hacksaw             6” x ½ ” – 1 No
  7.   Knife               Stainless steel sharp 4” knife-
                           1 no
  8.   Wire Stripper       Combination cutter cum
                           stripper- 1 No
                           Nipper- 1 no
  9. Hammer                250 gm ball pin hammer
  10. Insulation Megger    1000 v hand Driven megger, -
                           1 no
                           Make-MECO
             PROCEDURE
The whole procedure of the casing and capping wiring is stated
below: -
  • At first, electrical drawing is studied and take down material
    list and tools of the wiring installation, as per tables.
  • The tools list was prior given, and we take all tools as per
    list.
  • Then the materials are bought from the JU office workshop.
  • A small idea made by team members.
  • Thereafter casing and capping are cut as per size.
  • Then main switch is installed.
  • After that SPNDB is installed as per figure.
  • Switch board is also installed with proper switch connection.
  • Then casing is fixed with screw on the wall as required.
  • Then wires are cut by wire stripper and laying as per
    diagram.
  • Then power plug point is fixed as per diagram.
  • Switches are also interconnected as per diagram.
  • An earth bus is also installed, with a proper measurement of
    the system.
  • Earth wire is also connected with the system with green
    wire.
  • Holder is installed for bulb connection.
  • Ceiling rose is installed for fan connection.
  • A bell push switch is installed for a bell connection.
  • At last, whole connection is completed as per circuit
    diagram and gone for testing.
                 TESTING
Testing is taken a vital role for s installing electrical
system. Here testing is also done after the wiring. At
first visual checking of all wires terminals for
connection is done.
  • Insulation Resistance is checked by IR megger.
    With load off condition.
     Sl. No.         Position             IR Value
       01          Phase-Neutral           200MΩ
       02           Phase-Earth            200MΩ
       03          Neutral - Earth         200 MΩ
    With load ON & connected condition.
     Sl. No.        Position              IR Value
       01      Phase+Neutral - Earth       200MΩ
       02         Phase – Earth            150MΩ
       03         Neutral – Earth          150 MΩ
       04        Phase - Neutral            0 MΩ
  • Then continuity test is also done by series lamp test
    method before power up. The result is ok.
  • A load is connected with all respective points and
    the results will be response ok.
  • At last, the wiring is completed.
 Remarks: -
   ➢ From my side the wiring diagram is ok.
   ➢ Casing and capping are not straight because of lack of
     measurement, and absence of level pipe (water column).
   ➢ I learn the overview of a casing capping wiring.
   ➢ I also learn about the switch connection and electric bell
     connection.
   ➢ I learn that the estimation and costing of a electrical
     installation.
   ➢ Precaution during IR-megger test is well informed.
   ➢ Reason of Series lamp testing is verified by making
     deliberately shorting for fault.
Conclusion: -
 In conclusion, the report on casing and capping wiring
 highlights the importance of these protective measures in
 electrical installations. Casing provides a secure
 enclosure for wiring, safeguarding it from physical
 damage and environmental factors. Meanwhile, capping
 ensures a neat and organized appearance while offering
 additional protection. Together, these practices contribute
 to the safety, longevity, and efficiency of electrical
 systems, making them essential considerations in any
 wiring project.