0% found this document useful (0 votes)
265 views9 pages

Manual-Servomotor - 21.1

Uploaded by

Tarik Ztn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
265 views9 pages

Manual-Servomotor - 21.1

Uploaded by

Tarik Ztn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 9
Manual > Servo Barrier Gate Contents 1. Bret Introduction, 7 2 Functions and Features 1 3. Technical Data, 1 4. Mechanism Structure 2 5. Installation Direction Definition 2 6, Mechanical Part Iostllation and Adjustment. 3 6:1 Installation of Cabinet, 3 3 5 ‘ 7 {62 Spring Selection, Installation and Adjustment. 6.3. Mechanism Installation Direction Change (6.4. Motor Hand-Whecl Lock Ustge. 7. Contoller Explanations and lasteuctons 11. Contraller Interface Explanations 7.2 Contraller Menu Soting Explanations 73. Function Explanations 5 7.4. Controller Aute-Detect after Power-On Description, ° 8. Common Malfunctions and Solutions to 9, Wasranty and Service tems 10 10, Maintenance 10 11 Packing List " Appendix 1. Remote Control Coding. TL Wising Diageam for R&G Light Interface 12 MI, Drive Requirement for Main Control Board Wire Control 2 1V, Wire Dispram for Two Brier Gates Work Online 1B V. RS44S Communication Protocol. Le VL Digital Tube Display Character Interpretation. 15 Warning! For safety, please do follow the instruction strictly to manage this product: 1. Itis forbidden to open the barrier eabinet top caver ar door when itis working, 2. There must be a grounding connection for the barrier cabinet. 5. Make sure there is no person or any obstruction under the boom when ‘is falling 4. Before delivery the barrier gate spring and the boom length are well- balanced. It is not allowed to change the boom length randomly. If needed, please check with the technician, 1 Brief introduction 2. Functions and Features 23. redirection boom holder design lellastalaion sad eightostllaion can be fichanged easily and quickly 24 Selideteecate power-on open/close speedisadjusable 2.5. Withautoxeversingon obstruction function 216 Infrared phoroclitrfae i avaiable, need 9 natal photoesll device 217 Loop etecor interface svallabl, i avoid hing the veel, and contol the boom falling down automaticly after veel passing. (eee ntl lop tector) r Inprovetbeteneetcieney. ” 29 ulna delay auto-cosing futon, coordinated with counting fusction i the bumbets of vehicle passed les than the stored number, che boom will fll down ‘utomaiclly by eountdowe, but willbe ew countdown If thre up or lop detector Siena. 2110" Integrated RSAKS communieston interface, to realize contol of harser fpencloseby sompaterand arin ate gers 2114, 4digit dial tube dispay, display more information 3. Technical Data 51, Working somperatare moto: JUC- FAS 2.3. Moto Power LODW MAX 3.5. Distance of emote contol 250M ONE TECH 4, Mechanism Structure Spring Loek-mut Balance Spring S10V De Brushes Motor Handorhss and Lock ewe) 5. Installation Direction Definition ‘When placing the order, please confi Figuesastetow *tinsaled” or Vahcnsalled Lefionalled Rightnsalleg ee Se theletloresease|_ igwe2) 6, Mechanical Part Installation and Adjustment i 6 tnvalation abies, Neer et eee ee scat ecco Bl Place, andthen Sx th brit cabinet with expenion Balt. (eferto Figure 3) (gue) Cabinet Fixing Bat (According tthe supplementary iz) 6.2. Spring selection, installation and adjustment ‘The batir gate elladjustod before delivery. Ifneed cutoff the boom, please ‘men Boom Levath Selection” inthe contol unit 0 ensure the seth operation ofthe barrier, 624. Spring selection ‘The enghof spring prevals in kod, designing change without note i selestion plese refer to the spring table which stick on the oor of the ston disassembly and replacement spring force i oa weak, need to tight the spring fhe boom iting ep means the Spring Fore is00 strong need ofoosen he spring 2 ONE TECH 6.3. Mechanism installation direc icra Grier mechanig a an exznpe The below decipon lng yoo bow to change fom lfvinstalld to rgh-insalled 631. Disassemble boom holder: ake out the LOMM serew by turoing SMM Allen trench counterclockwise; And then push out the boom holder by toring wrench "lockwise with [SNM 150 res 163.2 Change the mechanism installation direction dissremble 6 sete 8MM srewe Airecuon ange sHoished (ep) 92) (ep) > ter) 6.4. Motor hand-wheel lock usage Duting owe off can uss noforband-whecl look to lock, Ses the photo a flowing, pull the Bande ino the fxed slot to Tock. When power oo, pall out tbe bundle to Uo. o te coutoler wil display Beet isplaying Er, wed lock anda power onagain) 7. Controller Explanations and Instructi 6 ‘ascent nrcvrpinating al oo ee ok ii Mice res a oP mans wi 12. Controller menu settings explana renter eee ee Tees Sar oak weccton os ee preving time: 0X, setting contents are regular menu items (P1-P9). ong etting ie: S0eX,seting counts are advanced men ites (PA, Pad Pe). PLLX Aut-reversng on cbitution function: 0: Stop os obtsucton 2 Light intensity (Coast) SeMid intensity (anit: seconds) 6 XX Room horizontal adjustment O0 140 gears P7-XX Boom vertial adjustment: 00 25 gears PRX.X Roomupspeed: —n, CBOISV-H 12/15 /2.0(Boomlength <4, 3M) P9.X.X Roomdown speeds CROISV'1:3, 0/4. /5.0 (Room ength 6M) Note:The nusbe ispatsing sped, ics seconds PAX Autovaging tes O:Clse(dtauld) : Open b-X Sign type: 0: Norma lose; : Normal open (deful) e.X Leamlagmode aher power-on: 0: Boom upand down (sfaul); 1: Boom up aly Pd_X Motor hand-whee eck motoring: 0: not monitoring: 1: monitoring (deel) 7.3. Function explanations Record the uber mes (8) for Boom up by wire control. When he number (N) of coeverse (if up oF [Appendix V for dla). When wing upper system such a computer) tcanea, cn 8 sacle im the vectial poston (Note I he sen is 9090 degrec, the Tesening SSS heomdown speeds PaAeaging teat O°" Pecos raion tos, te poe if nyse Hom wih conte TH Baeris'tne laput typeof “stop, "loop detector" and “photooeI" of 1 signal. "Normally Opes means che response action when the signal and common Ee re ecu atney gga ‘rorkiag with s'long fence Boom the bacticr may not be able ta close due to the {allure andthe status of motor Hasd-whcel lock stl prompt crvor mesage (Ee 6). SUPA tobe (cose motor hand-wheel lock monitong fonction) it he baie ate sonttemporans 7.4. Controller auto-detect after power-on description ‘The coulis shouldbe leening the position of boom aller power-on: The barter tae will slowly open andthe lose ons tine by default. Dating lean process, 1 fcocsallopea aed at-busping sgn inrfae, and will sop fearing hee is Signal Meant he dita ube displays ths elated signal ibfonmation (eet to ‘Appendix Vi), and elearning alr the sigaal dlsppeuts Aer Sash ean, the Boom stays athe dowa hat poston The dail tube wil display "Ee 1 the barter installed spring but to boow, oF ihereis obstruction on thom dari up o down ploces rhe spring and boos In fous imbalance, need o remove the obrruton or ajust the epi. thea power-on a Teining mode is “Boom up only" he barier gate wll ope to up limit psiin, ‘nd got lose: ding learing process of opening. the Date eat ope io up Lt Pasion due to obstuction,alough prompted Sais Tearlag, ut cant close Eom 3 ONE TECH 8. Common Malfunctions and Solutions LL Packing List 8.1. When power-on, press “UP” or “DOWN? bution, there fs no = SS LL rexetion on the boom. in BNL Checkup the power supply andthe Foxe Seems Nos onPed [sarzera [2 | sets_| Fixing teboom RiSCcheek whether tere corshannel ntefrcnce, and press the buttons onthe Ton oder Pastis Cover Tf se [Option 8.2. The barrier gate closes half, and then stop lear controller sell-test after power-on 8.3. Fence boom or 6m boom lifts up automatically when closing. 9, Warranty and Service Items a offered for component pai on eat waranty He (0 tnelades the buries boom or ems) 93, Technical questions are supported. 942. Thepowersuppy isnot stable, overthe mage of permitted voltage oot accordant osufty electric wing standard appearance of product. ” ‘44, Natural disaster casos damageto the product ing, during 10. Maintenance 1.1 Keep he barter gat cea, 10.4: Chee the esly worn-out pats every bal year and ene 10.5. Remote control distance wil Be shortened or not workin ees ik big objet Bxpansionseews | wigeiso | 4 | ssi [Fininethecabine Keys 2 |pee_| Foreabinet door Appendix I: Remote Control Coding Tighing io Meshing #imeston off Taat mean lena ws (Note ering Teasing, emote cotaier or seconde ar press tint continuously) indir af recelver, adess below i 1OXNONIE [arming lene ake ut he bate Beforecosing) ollcpco. u 10 Appendix 1 Red & Gree ight inertace cf Appendix ITI. Drive Requirement for Main Control Board Wire Control a | YS RaS! b v = Relay control mode fe SEM oO SAL Appendix I WorkOntime {ORS#85 valine mode: The conollr which connects with open signal and loop thehos conraller and slave cnsolerby wie (recommended twisted pair). This (QWire conta online mode: Corsect “COM, Open signal, lose sig, Lop signal Sto ign” af wte contol interface on two controllers y wie, need dps ite a Teas ifthe quantity of pre-uried wires nnot enough, the tldom ured op signal tobe ignored) Note: innigher quirements, the above two modes canbe veda the sametine Besidr, the ead othe radio receivers oftwo asi gates cm be sel sme, 0 Wire Diagram for Two Barrier Gates eat ia ‘ OH) | |i 6 12 Appendix V. RS485 Communication Protocol Dre Fonnat sen Sy upper system: Dat ender fda) | Address Command (ta) isd codt ff. However, XX cannot be orf adden in olowing exampe 00), Data fonnat tured by controler: Dstaheader (1200) Aadrest | Command | (Guts) "End code id), Some commonly used commané tbls (arent in folowing example x1), fr more fommand peste ark our cuntomerericeforclectroni les), 1 Upper system sends search command: 00 5 ‘Barrer controller refuns OD atenmediat limicpeation Hiketarrier isthe up int position, the eturn seam code f4 001 09 fa cna code £40001 00 eta (9 pt limi postionde down to zeta coe: (4000183 fa eh cde F100 01 03 fd (ote: After the lock command takes effet, the bate contoler ao Longer reaponds {any aetion only accepstheuslock commando teste) Appendix VI. Digital Tube Display Character Interpretation ‘Malfunction information description and solution Ee Memory lure Solution Change anew contol or eting the menu well when power-on to make the barter gate ea temporary emergeney ose Er 2 Curreat detection sree Solution Caange anew contra 3 Motorca'the detected or moto iret it aboormal Solan: Check fall motorrsated wie ten good const, Er Fncoderdate ost of range Solin: Check fhe conrliermatehes the barrier mechanism, x 5 Position earning fled Solaion: Check the spring is seriously out of balance Er 6 Motorbandeuhel lock enotunlocked Solin: Cheek Wmatorhand-wheel lock unloske, I Input signal after power-on prompt information description EL LO Theres STOP signal input fom wie contol ELI Theres CLOSE sigoa input om te contol Et L2 Theres OPEN sign input rom wire coma [ELS Theres gal from lop detector [EC L& There ie egal fom photos ELS There ir STOP signal fom remote cone Er Lb Thereie CLOSH signal rom remote somo EL? Theres OPEN sign feom remote cont Limit status display description ogc Uptimiangel xtmeane he angel és Dowalimitend closing sped, nx means osing speed sxe _ Motor temperature display xxx means temperature valoe eye Delay nsorciosng, ex means countdown tine Sex Timer ofopen memories when open he counting anstion, wx means times ‘peningicosing process dsplay deseription ot sncollupmeans opening. xx meats pening sped “ftol down mean oping, ax meats open speed Auto-reversing on obstruction prompt erat 15 ONE TECH

You might also like