                                      Energy storage technologies have gained considerable momentum in the recent years owing to the
                                      rising tide of renewables. The deployment of energy storage is a trend set to continue into 2018 and
                                      beyond. In the near future, compressed air energy storage (CAES) will serve as an integral component
                                      of several energy intensive sectors. However, the major drawback in promoting CAES system in both
                                      large and small scale is owing to its minimum turn around efficiency. In the present work the major
                                      drawbacks associated with various existing configurations of CAES system are analysed. Interesting
                                      results of Isothermal CAES system are obtained through the present analysis to generate additional
                                      output energy compared to the supplied input by harnessing the free energy from the natural water
                                      bodies/ocean to enhance the overall turnaround efficiency of the system. The optimum operational
                                      characteristics of charging and discharging cycles are also addressed. In the present energy scenario,
                                      increasing the percentage of renewable energy (RE) share in the power generation is quite challenging
                                      since RE based power generation is intermittent in nature. The integration of energy storage
                                      technologies with RE source is imperative as it mitigates the intermittency of available energy.
                                      However, the development of efficient energy storage systems is one of the prime challenges in the
                                      promotion of renewable energy in a large scale. Among the various storage systems, electrochemical
                                      battery storage and pumped hydro storage (PHS) have attracted the commercial market. However,
                                      the shorter cycle life makes the battery storage more expensive and the PHS systems involves certain
                                      geographical and site constraints. Beyond the said storage systems, compressed air energy storage
                                      system which is one of the technically proven system has not been targeted the commercial market
                                      owing to its lower turnaround efficiency. Hence, the motivation behind the present research is towards
                                      developing efficient CAES configuration with higher turnaround efficiency thereby attaining economic
                                      feasibility and sustainability.
                                      Kittner et al.1 deployed the various strategies for the emerging energy storage technologies and made a clear route
                                      towards cost effective low carbon electricity. In the recent years, bulk energy storages are gaining large momen-
                                      tum in order to improve the grid stability and to avoid transmission congestion issues. Compressed air energy
                                      storage (CAES) is considered as one of the promising large scale energy storage systems with attractive economic
                                      benefits. While, discussing the principle of operation, the energy is stored in the form of compressed air by oper-
                                      ating a compressor during off peak hours with RE sources and the stored compressed air is released during peak
                                      hours through an expander and the electrical energy is generated using an alternator. However, it is well known
                                      that in the entire energy transfer and conversion process, the considerable energy loss associated with all the three
                                      phases of storage system (charging, discharging and storage) are inevitable.
                                      1
                                       Institute for Energy Studies, CEG, Anna University, Chennai, 600025, India. 2Department of Mechanical Engineering,
                                      CEG, Anna University, Chennai, 600025, India. Correspondence and requests for materials should be addressed to
                                      V.R. (email: velrajr@gmail.com)
                                   Hartmann et al.2 analysed the efficiency of one full charging and discharging cycle of several adiabatic com-
                              pressed air energy storage configurations. They concluded that the key element for improving the efficiency is to
                              develop a high temperature thermal storage and temperature resistant material for compressors. Kushnir et al.3
                              studied the thermodynamic response of underground cavern reservoirs for the analysis of charge/discharge cycles
                              of compressed air energy storage plants. Based on the mass and energy conservation equations, numerical and
                              approximate analytical solutions for the air cavern temperature and pressure variations were derived. Audrius et al.4
                              conducted exergy and exergoeconomic analysis of a CAES system with and without Thermal Energy Storage (TES)
                              and found an increase in energy efficiency to 86% and exergy efficiency to 55.8% for the CAES-TES system in com-
                              parison with CAES system alone, which reported energy efficiency of 48% and exergy efficiency of 50.1%. Nejad
                              et al.5 undertook thermodynamic analysis of a wind integrated CAES system and they revealed the fact that the
                              energy conversion process could be adiabatic or isothermal. The major parameters in their analysis were storage
                              pressure, temperature and tank volume (TV). Li et al.6 proposed a novel micro trigeneration based compressed
                              air system with thermal energy storage technologies. They have also performed the thermodynamic analysis and
                              found that the average comprehensive efficiency is around 50% and 35% in winter and summer respectively that
                              appears to be much higher than the conventional trigeneration system. A near 4 MWh underwater CAES system
                              was numerically simulated to obtain optimal system configuration and the maximum round trip efficiency7–9.
                              In such systems, the accumulators are placed underwater utilizing the hydrostatic pressure exerted by the sur-
                              rounding water bodies10,11. Nielsen et al.12 proposed a concept of isobaric adiabatic CAES system integrated with
                              combined cycle. Houssainy et al.13 performed thermodynamic analysis of high temperature hybrid CAES sys-
                              tem eliminating the need for combustion in the traditional CAES system by incorporating two stages of heating
                              through separate low temperature and high temperature TES units. Safaei et al.14 suggested that exporting the heat
                              of compression to meet the space/water heating applications would contribute to the improvement of the overall
                              efficiency. Simpore et al.15 performed dynamic simulation and observed the feasibility of utilizing CAES system
                              integrated with a building in the case of PV power generation and the same was demonstrated. Trujillo et al.16
                              performed transient simulation analysis for CAES system without any thermal energy recovery unit and auxiliary fuel
                              systems. Various studies17–31 were conducted to analyse the different configuations and performance of CAES system.
                                   The first utility scale CAES system was commissioned at Huntorf, Germany in the year 1978, with the genera-
                              tion capacity of 290 MW, where the air is stored in the cavern with volume of 3, 10,000 m3 and with the operating
                              pressure range of 46–72 bar. Subsequently, in the year 1991, another CAES based grid scale plant was commis-
                              sioned at McIntosh, Alabama, USA with a generation capacity of 110 MW. In addition, the Energetix Group Ltd
                              has considered this technology as a backup power supply (Compressed Air Battery – CAB) for standard and
                              custom units from 3 kW to 3 MW which are made available for standby and uninterrupted power supply applica-
                              tions. This hybrid CAB facility is being adopted in British telecom sector as a third backup. This technology was
                              also claimed by Telecom Italia (Italy), Eskom (South Africa) and Harris (US). However, the success rate of this
                              technology remains difficult till today owing to the less overall turnaround efficiency of the system, arising as a
                              result of complexities involved in the discharging process. It is a fact that without considerably augmenting the
                              turnaround efficiency, attaining economic feasibility is questionable.
                                   In general, there are 4 major CAES configurations (i) Diabatic (ii) Adiabatic (iii) Advanced adiabatic and
                              (iv) Isothermal system. (i) A Diabatic Compressed Air Energy Storage (D-CAES) system is an energy storage
                              system based on the compression of air and storage in geological underground caverns. During the operation,
                              the available electricity is used to compress air into a large storage system like salt cavern at depths of hundreds
                              of meters and at higher pressure ranges depending on the depth of the cavern. The stored energy is released
                              during the time of peak demand and the air is heated through combustion by means of natural gas or fuel and is
                              expanded in a turbine to generate electricity. In diabatic CAES system, the heat of compression is not utilized and
                              it is dissipated as waste. In the same system natural gas is used for combustion to heat the air before the expansion
                              process during the discharging cycle. As discussed earlier, the existing two commercial CAES plants are being
                              operated under this configuration which tends to generate a larger amount of GHG emissions. (ii) In the adiabatic
                              system (A-CAES) the heat of compression is stored at a higher temperature and hence the generation of a larger
                              quantity of power output can be expected. An adiabatic storage system does away with the intercooling during
                              the compression process, and simply allows the air to heat up during compression, and stored in the CAES tank.
                              However, in reality, more mass of air could be accumulated when the air temperature is minimum and hence in
                              this configuration, in order to accommodate more mass of air at higher temperature the system demands for large
                              volume of storage tank which ultimately escalate the investment cost up. (iii) In the advanced adiabatic storage
                              system (AA-CAES) the heat of compression is stored in a thermal storage medium and, during the expansion pro-
                              cess, this heat is retrieved for heating the compressed air and the additional heat is supplied by external sources to
                              achieve higher power input. The initial investment required in this case will be little higher as a result of the addi-
                              tional thermal storage system and system heating involved. (iv) In isothermal storage configuration, (I-CAES) the
                              temperature inside the storage tank is maintained constant by removing the heat during charging and supplying
                              the heat during discharging process. All the above said process are represented schematically in Fig. 1.
                                   Recently an attempt was made to summarize all the existing researches carried out by various scientists on
                              Compressed Air Energy Storage system towards the efficient utilization of the intermittent Renewable Energy
                              source. The consolidated report made through this effort was presented in (http://www.sciencedirect.com/sci-
                              ence/article/pii/S1364032116301125). Several experimental attempts were also made in our lab during the last
                              few years to understand the most suitable configuration to store energy in the compressed air form. Several
                              research groups, across the globe have shifted their attention towards this potential area. Some of the below
                              mentioned research findings have triggered our interest in a diversified manner that resulted in the proposal of
                              this new concept of utilizing the naturally available thermal energy in the ocean/large water bodies for energy
                              conversion, while utilizing the RE source integrated with CAES system.
                              Figure 1. Various configurations of CAES system. (a) Diabatic storage system – Heat of compression is
                              dissipated as waste. (b) Adiabatic Storage system – Heat of compression is not dissipated and stored as such
                              in CAES storage tank. (c) Advanced adiabatic Storage system – Heat of compression is stored separately and
                              utilized before expansion process. (d) Isothermal storage system – CAES tank is maintained at a constant
                              temperature during charging and discharging processes.
                              •   The research group headed by Yulong Ding, University of Birmingham, has started utilizing the cryogenic
                                  energy available during the expansion of compressed air for liquefaction of air.
                              •   A Canadian start-up hydrostor utilizes a proprietary isobaric system built underground cavern for air storage,
                                  wherein water from ocean/sea is circulated to a CAES tank to maintain constant air pressure. Further, they
                                  have deployed the design made by Seamus Garvey, University of Nottingham, to put air bags under the sea
                                  at the required depth based on the pressure to be maintained (400–700 m) to utilize the static pressure of sea
                                  in a passive way.
                              •   SustainX achieved isothermal cycling by utilizing the heat of compression available during the charging,
                                  which is stored in water and reutilizing the stored heat in the water during the expansion process in order
                                  to achieve isothermal compression and expansion. A similar kind of concept was utilized by LightSail by
                                  spraying water during compression and reutilizing that warm water spraying during the expansion process.
                              •   The research team headed by Jihong Wang, University of Warwick, developed a multimode control strat-
                                  egy for air motor supply pressure control. Further, the patented technology mentioned in the link (https://
                                  www.google.ch/patents/US2863288) has claimed the invention of prothe control of air turbine governor for
                                  obtaining a constant air pressures supply/constant pressure ratio/constant speed for driving the machine
                                  (air motor). Further, yet another research team from the University of Birmingham has suggested a method
                                  called multipoint optimization. It is an optimization approach which is performed for a range of operating
                                  conditions to ensure acceptable performance levels in the turbine at this operating range.
                                  The present research work focuses towards achieving higher turnaround efficiency through a novel concept
                              of keeping the CAES in a large water bodies and thereby extracting the heat from the surrounding water bodies
                              during the energy conversion process. A detailed thermodynamic analysis performed for the above said configu-
                              rations along with the data analysis is explained in the methods provided at the end of this paper and the results
                              are presented in the following section.
                              Results
                              Figure 2 shows the transient variation in the pressure and the mass flow rate of air in the CAES system for the
                              analysis performed under different storage tank volumes (3 m3, 4 m3, and 5 m3). It should be noted that the work
                              input available is 1 kW for the compression process and the process is isentropic. The increase in temperature of
                              air at the end of compression is removed through a heat exchanger before it is allowed to enter the CAES tank
                              and the tank is always maintained at isothermal condition. It is seen from the figure that the mass flow rate of
                              air entering the tank decreases when the pressure inside the storage tank increases and as the work done by the
                              compressor is prominently used to oppose the pressure resistance developed inside the tank.
                                  Further, it is observed that the time required to develop 50% of the total pressure difference (i.e 1 bar − 4.5 bar)
                              is 26.4% of the total time taken for the charging process in all the storage tank volumes considered. Similarly the
                              time required for charging 75% of the total pressure difference (i.e 1 bar − 6.25 bar) is 47.1% of the total time
                              taken in all the three cases. The remaining 25% of the pressure development (i.e. 6.25 bar – 8 bar) requires 53% of
                              the total time required. This clearly explains that during the charging process the occurrence of first 50% pressure
                              development takes place in an accelerated mode, the intermediate 50 to 75% pressure development takes place
                              in a normal mode and the final 25% pressure development takes place in a decelerated mode. Hence, the exit
Figure 2. Variation of mass flow rate of air and pressure inside the storage tank during charging process.
                              Figure 3. (a) Instantaneous and cumulative work input during charging process. (b) Instantaneous energy
                              stored and cumulative energy stored in CAES tank during charging process. (c) Instantaneous and cumulative
                              heat energy rejected from the compressed air and stored in the TES tank during charging process.
                              pressure of the compressor should be at least 1.5 times (i.e. 12 bar in the present case) higher than the desired
                              maximum pressure of air in the storage tank for an appreciable reduction in the work input by the compressor.
                                  Figure 3 shows the various energy quantities associated during the charging process. During this process,
                              the compression is considered as isentropic and the work input given to the compressor is converted into heat,
                              resulting in increase in the temperature of air along with the increase in pressure. Figure 3(a) shows the instan-
                              taneous and cumulative work required to compress the air during the charging process. It is considered that all
                              the components are operating with 100% efficiency and hence the energy/work quantities obtained at the end of
                              charging process obeys the energy conservation law. The instantaneous work refers to heat transfer/work transfer
                              evaluated in a small time interval and it is considered as 1 minute in the present transient analysis. It is seen from
                              Fig. 3(a) that the instantaneous work input is 42 kJ/min during the start of charging process and it decreases to
                              zero kJ/min within a duration of 249, 331 and 414 minutes respectively for the storage volumes of 3, 4 and 5 m3.
                              The cumulative work required is 4260, 5680 and 7100 kJ respectively for the storage volumes of 3, 4 and 5 m3.
                                  Since the compression process is considered isentropic (δQ = 0) the work input given to the compressor is uti-
                              lized for increasing the internal energy of the air along with the increase in pressure. Figure 3(b) shows the instan-
                              taneous and cumulative pressure energy accumulated in the CAES tank at isothermal condition (atmospheric
                              Figure 4. Variation in the pressure and mass flow rate during discharging process under different storage tank
                              volumes.
                              Figure 5. Variation in outlet temperature of the expander and the cumulative additional cool energy generated
                              and the heat input supplied to maintain the isothermal condition in the storage tank for the constant generation
                              of 1 kW power output under different storage tank volumes.
                              temperature). It is seen from the figure that the instantaneous rate of energy storage at the start of compression
                              is 21 kJ/min, and it decreases to a minimum level within a duration of 249, 331and 414 minutes respectively for
                              the storage volumes of 3, 4 and 5 m3. During these periods the cumulative pressure energy stored in the tank are
                              2100 kJ, 2800 kJ and 3397 kJ respectively for the storage volumes of 3, 4 and 5 m3. The difference in the cumulative
                              energy in the various tanks are only due to the variation in the mass (volume) of air in the storage tank as the
                              pressure in all the storage tank is same at 8 bar.
                                  The heat energy available in the compressed air is removed and stored prior to allow this high pressure air to
                              enter inside the CAES tank. Figure 3(c) shows the instantaneous thermal energy rejected from the compressed air
                              which is stored in the thermal energy storage tank for maintaining isothermal condition in the CAES tank. It is
                              seen from the figure that similar to the energy stored in the CAES tank, the instantaneous rate of energy storage
                              at the start of compression in the TES tank is 21 kJ/min and it decreases to a minimum level within a duration of
                              249, 331 and 414 minutes respectively for the storage volumes of 3, 4 and 5 m3. Similarly the cumulative thermal
                              energy stored in the TES tank is also 2160 kJ, 2880 kJ and 3702 kJ respectively for the storage volumes of 3, 4 and 5
                              m3. It is possible to utilize this heat energy either for heating application (or) to reheat the air before the expansion
                              process. It is seen from the results that the cumulative sum of total compression pressure energy stored and the
                              heat rejected which is stored in TES system are equal to the cumulative energy supplied as input at all instants.
                                  Figure 4 shows the variations in the pressure and the mass flow rate required to achieve 1 kW constant power
                              output from the turbine during the discharging process. It is observed from the figure that the expander operates
                              for a duration of 40, 53 and 67 minutes respectively for the storage volumes of 3, 4 and 5 m3. Further it is seen from
                              the figure that there is a slow increase in mass flow rate required till a certain point in all storage volumes and
                              thereafter the mass flow rate required increases considerably which is not practically feasible due to the difficulty
                              involved in the flow rate control arrangements. Hence, the extensive data were analysed and increase in mass flow
                              rate required compared to the start of the expansion was found to be 28% when the pressure at the inlet of the
                              turbine was 4.4 bar. The mass flow rate required was 34% higher when the inlet pressure was 4 bar. Nearly 30%
                              variation in the mass flow rate control could be achieved easily through flow controls and also the expansion device
                              can also be accommodated for the variations in the inlet pressure ratio of 1.8. Hence it is construed that the depth
                              of discharging should not go below 4.4 bar which is 1.8 times lesser than the initial pressure in the storage tank.
                                  Figure 5 shows the variation in the outlet temperature from the expander during the discharging process and
                              the cumulative cool energy available in the outlet air with respect to the ambient temperature conditions during
                              the discharging process under constant load condition. Further, the results are presented to show the amount of
                              heat energy supplied from the surrounding water to the storage TV of 3 m3, 4 m3, and 5 m3 to maintain the tank
                              under isothermal condition during the expansion process. The quantities of total heat energy absorbed from the
                              surrounding water at the end of discharging process are 2746 kJ, 3758 kJ and 4766 kJ for the TV of 3 m3, 4 m3,
                              and 5 m3 respectively. It is possible to extract the required heat from the surrounding water by designing a large
                  (Pressure range
                  1 bar–8 bar)          Charging Process                                Discharging process
                                        Time of operation   Work    Heat       Energy   Time of operation     Cool energy   Power    Heat input   Net surplus
          S: No   Volume m3             minutes             input   rejected   stored   minutes               generated     output   supplied     output/Input
          1       3                     249                 4260    2160       2100     42                    2400          2340     2433         0.62
          2       4                     331                 5680    2880       2800     62                    3180          3120     3731         0.62
          3       5                     414                 7100    3702       3397     67                    3960          3900     4766         0.62
Figure 6. Sankey Diagram indicating the energy flow in the Isothermal CAES system.
                                    capacity heat exchanger. Thus the system has the ability of utilizing the free energy from the ocean and able to
                                    produce more work than the initial work potential in the storage tank.
                                        The outlet temperature of air after the expansion process is initially at a very low level of 168 K. As the pressure
                                    in the tank decreases with respect to time, the outlet temperature also increases and, at the end of discharging
                                    process, the temperature will be close to 270 K. This cool energy is more precious than the power when some
                                    application is coupled with the CAES system for which a large quantity of cool energy is required. The quantities
                                    of cool energy that can be stored in a cool storage tank are 3960 kJ, 3240 kJ and 2460 kJ for the CAES TV of 3 m3,
                                    4 m3, and 5 m3 respectively.
                                    Discussion
                                    The thermodynamic analysis performed in the present investigation assuming that all the components involved
                                    in the system were operated with 100% efficiency. Hence the energy balance could be shown using the first law of
                                    thermodynamics and the same is represented using the sankey diagram as shown in Fig. 6, considering one full
                                    charging and discharging cycle. It is seen from the sankey diagram that the output energy available in different
                                    forms such as heat energy, cool energy and work output cumulatively accounting 1.62 times the energy given as
                                    input to the compressor. This additional 62% energy is taken from the surrounding water at atmospheric condi-
                                    tions as detailed in Table 1. This additional net energy is possible when the heat transfer fluid works between the
                                    temperature limits above and below atmospheric temperature conditions, so that the energy available from the
                                    atmosphere can also be brought into the system. Though there is a possibility of energy multiplication with a fac-
                                    tor of 1.62 theoretically, while implementing the system, in reality it involves several challenges owing to various
                                    practical constraints and efficiency factors involved in the system components.
                                        The various challenges involved along with the possible solutions to maximize the overall turnaround effi-
                                    ciency are explained in this section. In the present system, for capturing the heat of compression generated during
                                    the charging process and the cool energy generated during the expansion process hot and cool thermal storage
                                    systems are required along with compressed air energy storage system. The charging and discharging cycle will
                                    not occur simultaneously in most instances of the system operation. Hence, the heat energy and cool energy gen-
                                    erated during the process of operation cannot be utilized within the system by employing only the heat exchang-
                                    ers and thus the system demands the thermal storage systems. Once the storage system is employed there are
                                    several possible ways to utilize this cool and heat energy for other applications also when the usage for this energy
                                    has more value than the increased efficiency achievable within the system for cooling of air during compression
                                    process and heating of air before the expansion process. Figure 7, shows the applications possible with cascaded
                                    Phase Change Material (PCM) material based storage systems integrated with CAES system to achieve higher
                                    overall efficiency.
                                        During the charging process since the objective is to store the compressed air at atmospheric temperature con-
                                    dition by keeping the CAES tank inside the water body/ocean in the case of large CAES system, the compressed
                                    air from outlet/intermediate stages from the compressor is allowed to pass through the heat exchanger integrated
                                    with PCM at various melting points based on the need for various applications before it is sent to the CAES tank.
                                    Thus the entire heat of compression can be retained in the storage system and the final compressed air which is
                                    entering into the CAES tank at a temperature closer to the atmospheric temperature condition will lose only very
                                    minimal heat energy during the period of storage. However, this hot storage tank should be insulated perfectly
                                    in order to retain the heat for longer duration. Further, during the above charging process by using proper con-
                                    trols and the selection of suitable multistage compressor incorporated with intercooling, the required work for
                              Figure 7. Illustration for the proposed isothermal CAES system with PCM based TES systems suitable for
                              various applications.
                              Figure 8. Isothermal CAES Configuration with improved turnaround efficiency (Configuration considered for
                              analysis).
                              the compression process could be reduced appreciably. It is possible to retain nearly 75% to 80% of the heat of
                              compression at the required temperature so that the heat loss associated during the charging process would be
                              less than 25%. Since the compressed air storage tank is kept inside the water body the losses associated during
                              the storage process is negligible. The heat energy stored in the TES tank could be utilized for various other appli-
                              cations such as a thermal source for desalination units, industrial process heating and the low temperature heat
                              source for building space heating.
                                  During the discharging process, since there is a large thermal mass in the surrounding water, the transfer
                              of heat to the storage tank can be achieved very easily when there is a reduction in temperature due to decrease
                              in pressure. However, this may require a further heat transfer study to design the internal configurations of the
                              CAES tank with extended surfaces compensating the lower heat transfer coefficients in the air side of the storage
                              system. Thus, by achieving efficient heat transfer simultaneously during the discharging process, the abundant
                              heat from the water body can be brought into the system when the expansion leads to a negative temperature in
                              the CAES tank with respect to atmospheric conditions. Further, during the expansion process, the cool energy
                              generated after expansion causes the liquefaction of air which may create a problem in the expansion process.
                              However, this problem could be alleviated by allowing the fresh air through the cool storage system and removing
                              the water particles before the air is allowed to pass through the compressor which reduces the work required by
                              the compressor and also minimizes the problems associated with condensation of water during the expansion
                              process. The cool energy stored can also be utilized for various applications based on the storage temperature.
                              It should be noted that most of the countries located near the equator spend considerable electrical energy gen-
                              erated to produce cool energy. In the emerging RE scenario, if the CAES system is coupled with central cooling
                              system of building/large food preservation applications, then the overall turnaround efficiency may be highly
                              economical to commercialize this technology in the near future.
                                  The major take away for the readers from the above study are,
                              •   The proposed system will help the efficient deployment of RE sources by incorporating CAES system along
                                  with cool and hot thermal storage system and thereby improving the overall turnaround efficiency by har-
                                  nessing large thermal energy from the naturally available water bodies where the CAES tank is placed and
                                  bringing the concept of polygeneration particularly in islands and offshore regions.
                       Discharging Process
                                                                                              r−1
                       Instantaneous temperature at which the air
                                                                                  ( )
                                                                                               r
                                                                       Toe
                                                                             =
                                                                                       Poe                                                                 14
                       leaves the expander                              Tt              Pt
                       Instantaneous Cool energy generated             Q cs − inst = [m dis ∗ c p ∗ (Tamb − Toe) ∗ 60]                                    20
                       Cumulative cool energy stored                   Q cs − cum = ∑ iN= 1(Q cs − inst )i                                                 21
                       Heat energy supplied to maintain isothermal
                                                                   Q free energy = m t ∗ c v ∗ (Ti − 1 − Ti) − TV ∗ (Pi − 1 − Pi)                          22
                       temperature (free energy from ocean)
                       Symbols:
                       T                                               —                                                                                   Temperature in K
                       P                                               —                                                                                   Pressure in bar
                       V                                               —                                                                                   Velocity in m/s
                       m                                              —                                                                                   Mass flow rate in kg/s
                                                                                                                                                           Specific heat of air at constant
                       cp                                              —
                                                                                                                                                           pressure in kJ/kg K
                       m                                               —                                                                                   Mass of air in kg
                       W                                               —                                                                                   Work input (or) Work output in kJ
                       R                                               —                                                                                   Gas constant of air kJ/kg K
                       ∆t                                              —                                                                                   Time step size in seconds
                       E                                               —                                                                                   Energy stored in kJ
                                                                                                                                                           Specific heat of air at constant
                       cv                                              —
                                                                                                                                                           volume in kJ/kg K
                       Q                                               —                                                                                   Heat quantity in kJ
                       ϑ                                               —                                                                                   Specific volume in m3/kg
                       η                                               —                                                                                   Efficiency in %
                       ɣ                                               —                                                                                   Ratio of specific heats
                       Subscripts & Superscripts:
                       oc                                              —                                                                                   Outlet of compressor
                       ic                                              —                                                                                   Inlet of compressor
                       t                                               —                                                                                   Tank
Continued
                                 •   The present study leads to understand the requirement of the exit pressure at the outlet of the compressor
                                     should be 1.5 times higher than the desired maximum pressure of air in the storage tank in order to reduce
                                     the compressor power required appreciably.
                                 •   The Depth of Discharging (DOD), pressure in the CAES tank should not be go below 1.8 times lesser than
                                     the initial pressure in the storage tank during the expansion process in order to reduce the mass flow rate
                                     variation within 30% which is achievable by the existing control strategies.
                                 Methods
                                 Configuration considered for analysis.              After undergoing a detailed study about the various config-
                                 urations investigated and the recent advances attempted commercially by various companies, a novel passive
                                 approach is proposed to achieve a near isothermal condition by submerging/placing the compressed air storage
                                 tank under water bodies/ocean while the compressed air is discharged to generate power through air motor/air
                                 expander, thereby utilizing the infinite massive heat energy from the ocean in the energy conversion cycle. This
                                 concept is considered for a detailed thermodynamic analysis with certain operating conditions. Figure 8 shows
                                 the configuration considered for analysis in a microscale. It is assumed that the air from the atmosphere is com-
                                 pressed to 8 bar and the heat energy available in the compressed air is transferred to a hot thermal storage system
                                 before it is delivered to CAES tank. During the discharging process, while generating power using the expander
                                 certain quantity of additional cool energy is generated which is transferred to cool thermal energy storage tank.
                                 During this process the temperature of the air also gets reduced, when the pressure inside the tank decreases.
                                 However, as the tank is kept inside the large water body which acts as a thermal reservoir, it supplies the required
                                 heat instantaneously and maintains the temperature of the tank uniformly at 303 K. The methods to overcome the
                                 expected hurdles and the situations where this technology has potential applications in a medium and large scale
                                 are also discussed following the explanations elaborated in the results of the present analysis.
                                 Data Analysis. In order to analyse such isothermal storage systems, an in-depth thermodynamic approach
                                 is performed with transient data analysis. Normally any power transfer devices such as compressor and turbine
                                 are analysed under steady state conditions. However, the charging and discharging process involved in the CAES
                                 system makes it transient and hence the thermodynamic analysis is carried out with discrete time interval with
                                 a small time step. Further, the thermodynamic analysis is performed by assuming all the devices are operating
                                 with 100% efficiency and the heat transfer fluid as an ideal gas. The required work input to carry out the charging
                                 process is calculated by considering the initial power input of 1 kW in the present case study. Different thermo-
                                 dynamic variables and parameters are calculated for evaluating the instantaneous behaviour of the system, con-
                                 sidering the ideal gas equation, energy and mass balance. Hence, the thermodynamic variables during charging
                                 process (temperature, specific volume, pressure and flow rate) are determined at each time step. Further, the
                                 parameters of interest like instantaneous energy stored in the compressed air storage system and the rejected
                                 heat of compression which is stored in the hot thermal storage tank are also quantified and presented. The above
                                 parameters are evaluated considering different storage tank volumes of 3 m3, 4 m3, and 5 m3. Similar to the
                                 charging phase, the first law is applied to the storage system in order to determine the relationship between its
                                 instantaneous pressure, instantaneous temperature and change in mass of the stored air under various storage
                              tank volumes. In the discharging analysis it is assumed that the system delivers a constant power output of 1 kW
                              at all time with the operating pressure range of 8 bar to 1 bar. The cool energy generated at every time instant and
                              the energy harnessed from the water bodies to the storage tank are also calculated during the expansion. The
                              thermodynamic equations (1–20) utilized to evaluate the various parameters involved during charging, storing
                              and discharging process are presented in Table 2. The data analysis reveals a pathway towards utilizing the abun-
                              dant free energy from the natural water bodies like the ocean for the efficient operation of CAES system and also
                              unlocking the potential of renewable power generation.
                              Data availability.        The data that support the plots within this paper and other findings of this study are pub-
                              licly available with the corresponding author and the same may be shared based upon the request.
                              References
                               1. Kittner, N., Lill, F. & Kammen, D. M. Energy storage deployment and innovation for the clean energy transition. Nature Energy 2,
                                  1–6 (2017).
                               2. Niklas Hartmann, O., Vöhringer, C. & Kruck, L. E. Simulation and analysis of different adiabatic Compressed Air Energy Storage
                                  plant configurations. Applied Energy 93, 541–548 (2012).
                               3. Kushnir, R. & Dayan, A. U. Temperature and pressure variations within compressed air energy storage caverns. International Journal
                                  of Heat and Mass Transfer 55, 5616–5630 (2012).
                               4. Audrius, B. & Nick, J. Exergy and exergoeconomic analysis of a Compressed Air Energy Storage combined with a district energy
                                  system. Energy Conversion and Management 77, 432–440 (2014).
                               5. Nejad, S. & Iqbal, T. Q. Performance evaluation of a hybrid wind diesel Compressed Air Energy Storage System. In Proceedings of
                                  the 24th Canadian Conference on Electrical and Computer Engineering (CCECE), Niagara Falls, ON, Canada, 270–273 (2011).
                               6. Yongliang, L., Wang, X., Dacheng, L. & Yulong, D. A trigeneration system based on compressed air and thermal energy storage.
                                  Applied Energy 99, 316–323 (2012).
                               7. Jarosław, M., Krzysztof, B. & Łukasz, S. Compressed Air Energy Storage Systems. Journal of Power Technologies 96(4), 245–260
                                  (2016).
                               8. Cheung, B. C. Design of system architecture and thermal management components for an underwater energy storage facility,
                                  Master’s thesis, University of Windsor (2014).
                               9. Cheung, B. C., Carriveau, R. & Ting, D. S. Multi-objective optimization of an underwater compressed air energy storage system
                                  using genetic algorithm. Energy 74, 396–404 (2014).
                              10. Cheung, B. C., Carrivea, R. & Ting, D. S. K. Parameters affecting scalable underwater compressed air energy storage. Applied Energy
                                  134, 239–247 (2014).
                              11. Pimm, A. J., Garvey, S. D. & de Jong, M. Design and testing of energy bags for underwater compressed air energy storage. Energy 66,
                                  496–508 (2014).
                              12. Lasse, N. & Reinhard, L. Dynamic Simulation of an Innovative Compressed Air Energy Storage Plant - Detailed Modelling of the
                                  Storage Cavern. WSEAS Transactions on Power Systems 8(4) (2009).
                              13. Houssainy, S., Janbozorgi, M. & Kavehpour, P. Thermodynamic analysis of a high temperature hybrid compressed air energy storage
                                  (HTH-CAES) system. Renewable Energy 115, 1043–1054 (2018).
                              14. Safaei, H., Keith, D. W. & Hugo, R. J. Compressed air energy storage (CAES) with compressors distributed at heat loads to enable
                                  waste heat utilization. Applied energy 103, 165–179 (2013).
                              15. Simpore, S., Garde, F., David, M. & Lasvignottes, J. C. Design and Dynamic Simulation of a Compressed Air Energy Storage System
                                  (CAES) Coupled with a Building, an Electric Grid and a Photovoltaic Power Plant. 12th REHVA world congress, Denmark (2016).
                              16. Juan, P. P.-T. Transient analysis of a Compressed air energy storage system. International Journal of Science and Technology 3(2),
                                  145–164 (2017).
                              17. Safaei, H. & Aziz, M. J. Thermodynamic Analysis of Three Compressed Air Energy Storage Systems: Conventional, Adiabatic, and
                                  Hydrogen-Fuelled. Energies 10(7), 1020–1035 (2017).
                              18. Kokaew, V., Moshrefi-Torbati, M. & Sharkh, S. M. Maximum efficiency or power tracking of stand-alone small scale compressed air
                                  energy storage system. Energy Procedia 42, 387–396 (2013).
                              19. Brown, T., Atluri, V. & Schmiedeler, J. A low-cost hybrid drivetrain concept based on compressed air energy storage. Applied Energy
                                  134, 477–489 (2014).
                              20. Jannelli, E., Minutillo, M., Lavadera, A. L. & Falcucci, G. A small-scale caes (compressed air energy storage) system for stand-alone
                                  renewable energy power plant for a radio base station: A sizing-design methodology. Energy 78, 313–322 (2014).
                              21. Vasel-Be-Hagh, A., Carriveau, R. & Ting, D. S.-K. Underwater compressed air energy storage improved through vortex hydro
                                  energy. Sustainable Energy Technologies and Assessments 7, 1–5 (2014).
                              22. Kantharaj, B., Garvey, S. & Pimm, A. Thermodynamic analysis of a hybrid energy storage system based on compressed air and liquid
                                  air. Sustainable Energy Technologies and Assessments.
                              23. Zhang, Y., Yang, K., Li, X. & Xu, J. The thermodynamic effect of air storage chamber model on advanced adiabatic compressed air
                                  energy storage system. Renewable Energy 57, 469–478 (2013).
                              24. Jubeh, N. M. & Najjar, Y. S. Green solution for power generation by adoption of adiabatic caes system. Applied Thermal Engineering
                                  44, 85–89 (2012).
                              25. Bagdanavicius, A. & Jenkins, N. Exergy and exergoeconomic analysis of a compressed air energy storage combined with a district
                                  energy system. Energy Conversion and Management 77, 432–440 (2014).
                              26. Kere, A., Sadiki, N., Py, X. & Goetz, V. Applicability of thermal energy storage recycled ceramics to high temperature and compressed
                                  air operating conditions. Energy Conversion and Management 88, 113–119 (2014).
                              27. Marano, V., Rizzo, G. & Tiano, F. A. Application of dynamic programming to the optimal management of a hybrid power plant with
                                  wind turbines, photovoltaic panels and compressed air energy storage. Applied Energy 97, 849–859 (2012).
                              28. Wang, S. & Yu, J. Optimal sizing of the caes system in a power system with high wind power penetration. International Journal of
                                  Electrical Power & Energy Systems 37(1), 117–125 (2012).
                              29. Denholm, P. & Kulcinski, G. L. Life cycle energy requirements and greenhouse gas emissions from large scale energy storage
                                  systems. Energy Conversion and Management 45(13), 2153–2172 (2004).
                              30. Lund, H. & Salgi, G. The role of compressed air energy storage (caes) in future sustainable energy systems. Energy Conversion and
                                  Management 50(5), 1172–1179 (2009).
                              31. Lund, H., Salgi, G., Elmegaard, B. & Andersen, A. N. Optimal operation strategies of compressed air energy storage (caes) on
                                  electricity spot markets with fluctuating prices. Applied thermal engineering 29(5), 799–806 (2009).
                              Author Contributions
                              V.R. and G.V. conceptualized the initial ideas and data analysis was performed by K.V. and V.R. The concept
                              diagrams were performed by G.V. and the manuscript was drafted by V.R. and G.V. All the authors read and
                              approved the final manuscript.
                              Additional Information
                              Competing Interests: The authors declare no competing interests.
                              Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and
                              institutional affiliations.
                                            Open Access This article is licensed under a Creative Commons Attribution 4.0 International
                                            License, which permits use, sharing, adaptation, distribution and reproduction in any medium or
                              format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Cre-
                              ative Commons license, and indicate if changes were made. The images or other third party material in this
                              article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the
                              material. If material is not included in the article’s Creative Commons license and your intended use is not per-
                              mitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the
                              copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.