0% found this document useful (0 votes)
190 views1 page

Fp-Miscellaneous Details

1. The document contains diagrams and notes related to a fire protection system, including piping, valves, gauges, and sleeves. 2. It specifies that sleeves should be provided where piping extends through walls, floors, and foundations, with clearances between the pipe and sleeve. 3. A schedule is provided listing the sizes of branch lines and corresponding pipe sleeves.

Uploaded by

caryl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
190 views1 page

Fp-Miscellaneous Details

1. The document contains diagrams and notes related to a fire protection system, including piping, valves, gauges, and sleeves. 2. It specifies that sleeves should be provided where piping extends through walls, floors, and foundations, with clearances between the pipe and sleeve. 3. A schedule is provided listing the sizes of branch lines and corresponding pipe sleeves.

Uploaded by

caryl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REPUBLIC OF THE PHILIPPINES

NOTES:
SYSTEM PRESSURE GAUGE
AT HIGHEST FLOOR LEVEL (FOR INDICATING TYPE FLOOR CONTROL
VALVE W/ SUPERVISORY SWITCH
SLEEVES SHALL BE PROVIDED AROUND ALL PIPING EXTENDING THROUGH WALLS, FLOOR, OFFICE OF THE BUILDING OFFICIAL
UPFEED SYSTEM) PLATFORMS AND FOUNDATIONS.

BLINK FLANGE CONNECTION


SYSTEM PRESSURE GAUGE
1. THE CLEARANCE BETWEEN THE PIPE SLEEVES SHALL BE FILLED W/ NON-COMBUSTIBLE
FLEXIBLE MATERIAL SUCH AS MINERAL WOOL, FIBERGLASS OR EQUIVALENT. CEBU CITY, CEBU
2. MINIMUM CLEARANCE BETWEEN PIPE AND SLEEVES SHALL NOT BE LESS THAN 25MM
MECHANICAL GROOVE ELECTRICAL JUNCTION THROUGH .75MM & 40MM FOR PIPE SIZE 100MM AND LARGER FLOOR SLEEVES SHALL BE
WATER
COUPLING"VICTAULIC,
FLOW SWITCH BOX (BY EE WORKS) EXTENDED AT LEAST 75MM ABOVE THE TOP OF THE WEARING SURFACE. COVER SECURITY ACTUATOR COVER
"METRAFLEX" BRAND OR EQUAL TO BE FILLED W/ NON-COMBUSTIBLE
25Ø FCV DRAIN LINE STACKED
ELECT'L. CONDUIT SCHEDULE OF PIPE SLEEVES MATERIAL, MINERAL WOOL OR SCREW RECOMMENDING APPROVAL
300(MAX.)
(EVERY OTHER FLOOR)

TO FIRE ALARM CONTROL APPROVED EQUAL


TAPPED TO THE NEAREST DRAIN SIZE OF SIZE OF
PANEL (BY EE WORKS)
BRANCHLINES PIPE SLEEVES
100Ø AFSS RISER
PIPE SLEEVES
MOUNTING PLATE
AND DOWNFEED 25MMØ 50MMØ COVER SECURITY
PIPE SLEEVE PROVIDED
W/ NON-COMBUSTIBLE MAT'L.
32MMØ 50MMØ 5MM THK. STEEL FLANGE SCREW
MINERAL WOOL OR APPROVED EQUAL 40MMØ 65MMØ FIN. FLOOR WELDED TO PIPE SLEEVES
HEAD MECHANICAL SECTION DATE:
LEVEL FOR CONCRETE ANCHORAGE DIRECTION OF
50MMØ 75MMØ ROLL VANE (OPPOSITE
65MMØ 100MMØ
FLOW ARROW
OF FLOW ARROW) TO
75MMØ 100MMØ
MECHANICAL GROOVE COUPLING
FEEDMAIN CONNECTION LINE
INSERT IN PIPE
100MMØ 150MMØ PROPOSED PIPE
"VICTAULIC", METRAFLEX" BRAND OR EQUAL
150MMØ 225MMØ
HEAD MECHANICAL SECTION
PIPE SLEEVES
25Ø FCV DRAIN LINE
BALL VALVE
200MMØ 300MMØ MOUNTING HOLE
STACKED TAPPED TO
THE NEAREST DRAIN 25MMØ BALL VALVE
TYPE DRAIN VALVE
BUILDING OFFICIAL DATE:
100Ø AFSS RISER PROVIDE W/ FIRE
AND DOWNFEED RATED SEALANT
BLIND FLANGE CONNECTION SIGHT GLASS
TO BE FILLED W/
PIPE U-BOLT
SYSTEM PRESSURE GAUGE
AT LOWEST FLOOR LEVEL
NON-COMBUSTIBLE WATER FLOW
MATERIAL, MINERAL WOOL
(FOR DOWNFEED SYSTEM)
OR APPROVED EQUAL

CEILING LINE
R.C. WALL
ESCUTCHEON PIPE SLEEVE PROVIDED
PLATE WITH NON-COMBUSTIBLE MATERIAL,
MINERAL WOOL OR APPROVED EQUAL

FUSIBLE BULB 25Ømm

SIDEWALL TYPE FILLED WITH FIRE RATED OR


SPRINKLER HEAD FIRE STOPPING MATERIALS SIZE VARIES 25Ø-LESS THAN 6.0M
OR APPROVED EQUAL 32Ø-6.10 TO 11.90M 40Ø-12.00MM
& ABOVE 50Ø ANGLE VALVE W/
COMBINATION TYPE RESTRICTING
ANGLE VALVE AT FLR. LVL. W/
EXCEEDING DOWNSTREAM 4-#16 TW WIRE IN 15MMØ
PRESSURE OF 100 PSI. IMC PIPE (BY CONTRACTOR)
ADJUSTABLE PRESSURE SIZES VARIES 25Ø-LESS
RESTRICTING ANGLE VALVE THAN 6.0M 32Ø-6.10 TO SIZES VARIES 25Ø-LESS
BRASS POLISHED FIRE FOG 11.90 Ø-12.00M & ABOVE THAN 6.0M 32Ø-6.10 TO 4-#16 TW WIRE IN 15MMØ
ADJUSTABLE NOZZLE 11.90 Ø-12.00M & ABOVE "V" TYPE HANGER "U" TYPE HANGER FOR ADJUSTABLE CLIP FOR SIDE BEAM
40Øx30 M LONG RUBBER FIRE ALARM SYSTEM FLEXIBLE CONDUIT STUB-OUT
LINE COTTON FIRE HOSE FOR BRANCH LINE CROSSMAIN AND FEEDMAIN BRANCH LINE ADJUSTABLE (BY CONTRACTOR)
JACKETED W/ CHROME PIN
LUG COUPLING THREADED
10 LBS. DRY CHEMICAL TYPE 4-#16 TW WIRE IN 15MMØ
TAPPING POINT
TYPE ABC PORTABLE FIRE FLEXIBLE CONDUIT FROM FLOOR
EXTTINGUISHER (BY SPRINKLER WORKS)
CONTROL VALVE (TERMINATION,
PULL FLUSH MOUNTING DOOR BY SPRINKLER WORKS)
W/ TRIM FOR ALL GLASS PLATE PLAN PLAN ELECTRICAL JUNCTION BOX
SHALL BE GAUGE #18 W/ NOTE
ALUMINUM TRIM "BREAK GLASS IN CASE OF FIRE" (SURFACE MOUNTED) (RECESSED TYPE) (BY EE WORKS)

ELEVATION FIRE ALARM SYSTEM SUPERVISED FLOW SWITCHES


(BY CONTRACTOR) (BY SPRINKLER WORKS)

8-#16 TW WIRE IN 15MMØ


IMC PIPE TO FIRE ALARM
CONTROL VALVE (BY
CONTRACTOR)

FEEDER MAIN PIPE


CONTROL VALVE WITH
SUPERVISORY TAMPERS SWITCH
C-TYPE CLAMP ADJUSTABLE SWIVEL RING CENTER I-BEAM ADJUSTABLE FLAT (BY SPRNKLER WORKS) SYSTEM PRESSURE GAUGE
WITH RETAINING STRAP HANGER WITH EXPANSION CLAMP FOR BRANCH IRON HANGER
SHIELD LINE

45° 45°
CEILING LINE FLUSH TYPE
PENDENT SPRINKLER
HEAD MODEL SISO
BOTTOM OF SLAB R.C. WALL "STAR" BRAND OR
22Ø IN BOLT PIPE SLEEVE PROVIDED 25ØMM CLOSED APPROVED EQUAL
WITH NON-COMBUSTIBLE NIPPLEA
EXPANSION SHIELD ESCUTCHEON PLATE
MATERIAL,MINERAL WOOL
OR APPROVED EQUAL
CEILING
25Ø 32MMØ (MAX.)
SIDEWALL TYPE SCUTCHEON
CONCRETE WALL OR BEAM SPRINKLER HEAD 25ØMM-50ØMM
10
44.5Ø HOLE IN CEILING
"CENTRAL","BEST" BRANCH LINE 65mmØ
ROUND BAR
BRAND OR EQUAL FILLED WITH FIRE RATED OR FLUSH TYPE PENDENT
FIRE STOPPING MATERIALS
OR APPROVED EQUAL
45°
TYPICAL SIDEWALL TYPE
PIPE FLAT BAR ROUND
UPRIGHT TYPE
SIZE LOWER UPPER BAR SPRINKLER HEAD IF NOT OVER 609.6mm (24")
"CENTRAL","BEST"
FLAT BAR 65 4.8 X 32 4.8 X 32 12.7 BRAND OR EQUAL 25.4x12.7MM REDUCER
45° 45°
25ØMM-50ØMM BRANCH LINE 25ØMM CLOSED NIPPLE
75 4.8 X 32 4.8 X 32 12.7
PIPE
100 4.8 X 32 6.4 X 32 15.9 TYPICAL UPRIGHT TYPE

150 4.8 X 32 6.4 X 32 19 25.4x12.7MM REDUCER 45°


65 X 65 X 7MM TYPE INSTALLATION
200 4.8 X 32 6.4 X 32 25.4 WELD (TYPICAL) STEEL ANGLE MOUNTING PLATE
GYPSUM BOARD
CEILING FINISH
15Ø U-BOLT IF NOT OVER
609.6mm (24")
RECESSED TYPE
150Ø SPRINKLER RISER CLOSURE SPRINKLER HEAD
"CENTRAL","BEST"
63.5Ømm BRAND OR EQUAL
76.2Ømm
TYPICAL RECESSED PENDENT TYPE

45°

PREPARED BY: APPROVED BY: SEAL PROJECT TITLE: APPROVED AS PER PLAN : SHEET CONTENTS: SHEET NO:

EQUILIBRIUM
ENGINEERING
ALLAN M. ALAGOS
PROF. MECHANICAL ENGINEER FIRE PROTECTION WORKS FOR MISCELLANEOUS DETAILS FP-03
Yati,Liloan Cebu 6002
(032) 513 9108
REG. NO. : 4735
DATE:01-31-18
PTR NO.: 0827376
DATE:01-09-19
A PROPOSED 14TH STOREY ONE TECTONA BLDG REVISION: 1
2
Page 3 of 3

equilibriumseal@gmail.com CAD BY: DCC


TIN NO.:241-201-520 LOCATION: ADDRESS : 3