Indicating Temperature Switch
Indicating temperature switch combines indication with switching (in order to make or break the associated electrical circuit).
                 Can be offered with contact assembly as well as microswitch (as a combination of switch and movement)
                 Features
                 n   Combination of indication and switch
                 n   Fast response
                 n   Choice of contact assembly or microswitch
                 n   Switching accuracy ± 2% FSD
                 n   High repeatability and low hysteresis
                 n   Flameproof version available
                 n   Case compensated system
                 Specifications
                 System                Gas (N2) filled case compensated in accordance with SAMA Cl. IIIB
                 Dial                  100 mm / 150 mm in aluminium, white background, black marking
                 Case                  SS304 / SS316 with bayonet bezel (Flameproof case in Al only)
                 Protection            Weatherproof to IP-68 (IS/IEC : 60947 / IEC : 60529)
                                       Flameproof to IIA IIB (Equivalent to NEC Cl. I Div 2 Gr. C&D)
                                       Flameproof to IIC (Equivalent to NEC Cl. Div 1 Gr. A&B)
                 Stem                  SS304 or SS316, 6 mm, 8 mm, 10 mm, 12 mm dia as standard
                 Connection            ½" NPT (M) adjustable three piece compression fitting as standard
                 Capillary             SS316 with SS304 / SS316 armouring or
                                       SS316 with SS304 / SS316 armouring, with PVC covering
                 Range                 (-) 200 to 800°C (minimum span 80°C )
                 Accuracy              ± 1% FSD for indication, ± 2% FSD for switching
                 Over range            125% FSD
                 Contacts              1) 1SPST /2SPST (Single/ Double) Electrical Contacts,
                                           independently adjustable over the entire Range, rated 30VA@230V AC
                                       2) 1SPDT /2SPDT (Single/ Double) Microswitch, independently adjustable
                                           over entire range, rated 5A@230V AC (3A@28V DC)
                                       3) Inductive Contacts (NAMUR), Single or Double, independently adjustable
                                           between 10% & 90% of the Range,
                                       Nominal Voltage, 8.32 V DC, Operating Voltage, 5 to 25 V DC
                 Accessory             Relay for the contact assembly to suit 5 amp @ 230 V AC, separately
                                       mounted.
                 Note                  1) Flameproof version is offered with SPDT Microswitch in Die Cast
                                           Aluminium housing only.
                                       2) Surface mounted flameproof housing is available with capillary.
                                       3) For minimum insertion length essential for proper
                                           sensing, contact our design department.
                                       4) Three point calibration certificate accompanies each thermometer.
                                       5) For operating temp>600°C; stem of SS310 / Inconel 600 shall be
                                           recommended.
                 Advantages of Microswitch Type Models: Microswitch is rated 5 amp @ 230 V AC (3A @ 28 VDC). No relay is required.
                 Microswitch is imported from reputed international supplier as combination of movement and switch.
                 Microswitch assembly gives better switching accuracy. Compact design.
10/17 REV.: 00
                                                             Under Technical Collaboration with M/s. Gauges Bourdon, France
                 www.generalinstruments.co.in                                             214                                            www.general-gauges.com
Ordering Information
GDT-SW-R - Rigid Stem
GDT-SW-C - Capillary Type
                                                           MODEL : GDT-SW-R / GDT-SW-C
            MOUNTING                                                                                                                                    OPTION
  V   Bottom Entry, Local Mounting                                                                                                      TW     Thermowell
  C   Back Entry, Local Mounting                                                                                                        CLB    Colour Band
  E   Every Angle, Local Mounting                                                                                                       DUS    Dual Scale
  S   Bottom Entry, Surface Mounting                                                                                                    1ST    1SPST
  P   Back Entry, Panel Mounting                                                                                                        2ST    2SPST
  Y   Bottom Entry, 2" Pipe Mounting                                                                                                    1DT    1SPDT
                                                                                                                                        2DT    2SPDT
                  DIAL                                                                                                                  1NR    NAMUR Switch, Single
  100 100 mm           150 150 mm                                                                                                       2NR    NAMUR Switch, Double
                                                                                                                                        REL    Relay
                                                                                                                                        FAB    Flame Proof Case (IIA, IIB)
                 CASE
  S4S SS304            S6S SS316                                                                                                        F2C    Flame Proof Case (IIC)
  ALM Die Cast Al***
                                                                                                                                                           UNIT
                                                                                                                                        DGC Deg C                DGF Deg F
             STEM-OD
  S06 6 mm             S10 10 mm
                                                                                                                                                   RANGE #
  S08 8 mm             S12 12 mm
                                                                                                                                    0 to 80                0 to 300
                                                                                                                                    0 to 100               0 to 350
          STEM LENGTH                                                                                                               0 to 120               0 to 400
             Specify in mm                                                                                                          0 to 160               0 to 500
                                                                                                                                    0 to 200               0 to 600
                                                                                                                                    0 to 250               0 to 800
         STEM MATERIAL
  S6S SS316 S4S SS304                                                                                                                   CONNECTION
  310 SS310** 600 Inconel 600**
                                                                                                          Conn Code Size              Code       Type      Code    Male/ Female Code
                                                                                                         Thread T   1/4”               06        NPS        NS          Male        M
                        CAPILLARY
                                                                                                                    3/8”               10        NPT        NT         Female       F
 4AR(*)    SS 316 Capillary, SS 304 Armoured
 4PV(*)    SS 316 Capillary, SS 304 Armoured+PVC Covered                                                                     1/2”      15        BSP        BP
 6AR(*)    SS 316 Capillary, SS 316 Armoured                                                                                 3/4”      20       BSPT        BT
 6PV(*)    SS 316 Capillary, SS 316 Armoured+PVC Covered                                                                      1”       25       JIS-PF      PF
 NIL        Not Applicable for GDT-SW-R type.                                                                                M20      M20       JIS-PT      PT
                                                                                                                                                 Gas        GS
* Specify the length of Capillary in Meters.                                                                                                      R         RR
                                                                                                                                                  Rp        RP
**Stem material of SS310 is recommended for Temperature 600 Deg. C
                                                                                                                                               Pitch 1.5     C
  and Inconel 600 for temperature above 600 Deg.C
                                                                                                         e.g. For 1/2"NPT(M), Code: T15NTM
*** for Flame proof case with microswitch only
                                                                                                              For M20x1.5 (F), Code: TM20CF
                                                                                                         # Ranges mentioned are in oC. Equivalent unit in oF can be provided on request.
                                                                    Sample Model Code: GDT-SW-C-S-150-S4S-S10-400-600-4AR(3)-T15NTM-(0-800)-DGC-2DT
                     The recommendations made in this catalogue are to be used as intended guide. No guarantee of material can be undertaken since other
                                                                                                                                                                                        10/17 REV.: 00
                     factors may affect the performance. We reserve the right to change the specifications mentioned in this catalogue without any notice as
                       improvements & development is a continuous process at “General”. Responsibility of typographical errors is specifically disclaimed.
www.generalinstruments.co.in                                                          215                                                                  www.general-gauges.com
                 Blind Temperature Switch
                            has been designing and manufacturing reliable, high quality
                 Temperature Switches for accurate control of the process equipments to suit to
                 most of the industrial applications in various process industries. With inert Gas
                 Nitrogen, our Switches are most environment friendly and Safe, which makes
                 them the ideal choice of almost all types of process industries / applications.
                 Features
                 n   Use of Inert Gas (Nitrogen)
                 n   Non-polluting, Environment friendly
                 n   Rugged construction
                 n   Rigid Stem or Capillary type
                 n   Weather proof or Flame proof enclosure
                 n   Fast Response
                 n   1SPDT / 2SPDT micro-switches
                 Specifications
                 System                 : Inert Gas (Nitrogen) filled System
                 Case                   : Weather proof, Die-Cast Aluminium enclosure, epoxy powder coated,
                                          conforming to IP-68 protection, in accordance with IS/IEC-60529:2001
                                          Flameproof Die Cast Aluminum Enclosure, epoxy powder coated,
                                          conforming to Gr. IIA, IIB & IIC T6 in accordance with IS 2148-2004
                                          (IEC-60079:2001) & Weatherproof to IP 66 in accordance with
                                          IS-12063:1987 (IEC-60529), approved by CMRI/CCOE/PESO
                 Cable entry            : As shown in Table-III
                 Stem                   : SS304 or SS316, 6 mm, 8 mm, 10 mm, 12 mm
                 Connection             : ½" NPT(M) adjustable compression fitting in SS316 as standard
                                          (other connections on request)
                 Capillary              : SS316 with SS304 / SS316 armouring or
                                          SS316 with SS304 / SS316 armouring, with PVC covering
                 Range                  : As shown in Table-I
                 Switching Accuracy : ±1% FSD
                 Repeatability          : ±1% FSD
                 Scale Accuracy         : ±5% FSD
                 Over Range             : 125% FSD
                 Switch Type            : 1SPDT / 2SPDT Snap Action Microswitch
                 Switch Rating          : As shown in Table-II
                 Set Point              : To be specified by Customer (Adjustable from 10 to 90% of the Maximum
                                          Range), Internal Setting with tamperproof locking arrangement
                 Switching Differential : Fixed or Adjustable
                 High Voltage Strength: Withstands 0.5 KV between open contact for 1 Sec & 2 KV between
                                          terminals and earth for one minute.
                 Insulation Resistance : Insulation Resistance >10 M Ohms at 500VDC
                 Thermowell             : Refer our Catalogue for Thermowell
10/17 REV.: 00
                                                          Under Technical Collaboration with M/s. Gauges Bourdon, U.K.
                 www.generalinstruments.co.in                                         216                                www.general-gauges.com
Blind Temperature Switch
Note:
1) Weatherproof enclosure is effective only if all entries and joint faces are properly sealed.
2) Flameproof enclosure is weatherproof only if cover 'O' ring is retained in position; and flameproof only if suitable Flameproof Cable Gland
    is provided. It is highly recommended to procure Cable Glands along with flameproof instruments to avoid negligence of the same during
    installation.
3) Switch Accuracy & Repeatability are one and the same for all Blind Temperature Switches (being a switching device; not an indicating/
    measuring device).
4) The instrument is calibrated in vertical mounting position. Hence mounting in any other position may cause a minor range shift.
5) Ambient temperature range: All models are suitable for operating within a range of ambient temperature from (–) 20°C to (+) 60°C
    provided the process fluid does not freeze within this range. Below 0°C, precautions should be taken in humid atmospheres to prevent
    frost formation inside the instrument from jamming the mechanism.
6) It is recommended to select the range of the instrument such that the set value falls between 35% to 65% of the FSR.
7) Scale Markings are for guidance only. Set the correct set value against precision Master instrument
8) Thermowells of different process connections & Material of Construction can be provided as per process requirement.
Table I : Ranges (in Deg. C)
  20 to 60                        (-)30 to (+)30
  20 to 80                        (-)30 to (+)50
  20 to 100                       (-)30 to (+)90
  20 to 120
  20 to 160                       (-)40 to (+)40
  20 to 200                       (-)40 to (+)60
  20 to 250                       (-)40 to (+)80
  20 to 300
                                  (-)50 to (+)30
  (-)20 to (+)40                  (-)50 to (+)50
  (-)20 to (+)60                  (-)50 to (+)100
  (-)20 to (+)80
  Any other (Please specify)
Note: Ranges mentioned are in Deg.C.
Equivalent unit in Deg.F can be provided on request.
Table II : Type of Micro Switch
    Description         Code             Availability          A/C Rating                         DC Rating
                                           In Type           Current Voltage                        Current
                                                                                 Volt      Resistive        Inductive
    1-SPDT              100            Fixed switching         5A-250VAC         220         0.25 A           0.03 A
                                       Differential only                         110         0.50 A           0.07 A
    2-SPDT              200                                                       24          5.0 A           3.00 A
    1-SPDT              102          Fixed or Adjustable       5A-250VAC         220         0.25A             0.1A
                                    Switching Differential                       110         0.5A              0.2A
    2-SPDT              202                                                       24          8A                7A
    1-SPDT              103          Fixed or Adjustable      15A-250VAC         220         0.25A             0.1A
                                    Switching Differential                       110         0.5A              0.2A
    2-SPDT              203                                                       24          8A                7A
    Any Special
                                                                                                                                                   10/17 REV.: 00
    Requirement         XXX                   —                    —             —             —                ---
www.generalinstruments.co.in                                               217                                            www.general-gauges.com
                 Blind Temperature Switch
                 Table III : Type of Cable Entry
                   Cable Entry                   Single Cable Entry       Double Cable Entries       Double Cable Entries, one plugged
                                                W/P           FLP          W/P           FLP                W/P              FLP
                                                          (IIA/IIB/IIC)              (IIA/IIB/IIC)                       (IIA/IIB/IIC)
                   ¾” ET(F)                     W10          F10           W20            F20              WP0                FP0
                   3/8" BSP(F)                  W11          F11           W21            F21              WP1                FP1
                   ½” BSP(F)                    W12          F12           W22            F22              WP2                FP2
                   ½” NPT(F)                    W13          F13           W23            F23              WP3                FP3
                   ¾” BSP(F)                    W14          F14           W24            F24              WP4                FP4
                   ¾” NTP(F)                    W15          F15           W25            F25              WP5                FP5
                   ¾”ET, DCCG - Brass           W1A          F1A           W2A            F2A              WPA                FPA
                   ¾”ET, DCCG - SS              W1B          F1B           W2B            F2B              WPB                FPB
                   ½”BSP, DCCG - Brass          W1C          F1C          W2C             F2C              WPC                FPC
                   ½”BSP, DCCG - SS             W1D          F1D          W2D             F2D              WPD               FPD
                   ½”NPT, DCCG - Brass          W1E          F1E           W2E            F2E              WPE                FPE
                   ½”NPT, DCCG - SS             W1F          F1F           W2F            F2F              WPF                FPF
                   ¾”NPT, DCCG - Brass          W1G          F1G          W2G             F2G              WPG               FPG
                   ¾”NPT, DCCG - SS             W1H          F1H          W2H             F2H              WPH               FPH
                   ¾”BSP, DCCG - Brass          W1J          F1J           W2J            F2J              WPJ                FPJ
                   ¾”BSP, DCCG - SS             W1K          F1K           W2K            F2K              WPK                FPK
                   ¾” ET, SCCG - PVC            PVC           ---           ---           ---               ---               ---
                   4 Pin Connector              4PC           ---           ---           ---               ---               ---
                   7 Pin Connector              7PC           ---           ---           —                 ---               ---
10/17 REV.: 00
                 www.generalinstruments.co.in                                      218                                                   www.general-gauges.com
Ordering Information
BTS-R : Rigid Stem type
BTS-C : Capillary type
                                                                  MODEL : BTS-R / BTS-C
            MOUNTING                                                                                                                                          OPTION
  V Bottom Entry, Local Mounting                                                                                                             TW Thermowell
  S Bottom Entry, Surface Mounting                                                                                                           L Nil
  Y Bottom Entry, 2" Pipe Mounting
                                                                                                                                       SWITCHING DIFFRENTIAL
                 CASE                                                                                                                 FD Fixed Differntial
  WA Weatherproof Alluminium                                                                                                          AD Adjustable Differntial
  FAB Flameproof IIA / IIB Alluminium
  F2C Flameproof IIC Alluminium                                                                                                                    Micro Switch
                                                                                                                                           Select the Range from Table-II
          CABLE ENTRY
  Select Code From Table III
                                                                                                                                                       UNIT
                                                                                                                                      DGC Deg C                DGF Deg F
      SENSOR (BELLOW)
                                                                                                                                                     RANGE
  BRZ Ph Bronze Bellow
                                                                                                                                           Select the Range from Table-I
  S6L SS316L Bellow
                                                                                                                           CONNECTION
             STEM D1A
  S06 6 mm          S10 10 mm                                                                 Conn Code Size             Code      Type      Code     Male/ Female Code
  S08 8 mm          S12 12mm                                                                 Thread T   1/4”               06       NPS       NS           Male         M
                                                                                                        3/8”               10       NPT       NT          Female        F
                                                                                                                 1/2”      15       BSP       BP
          STEM LENGTH                                                                                            3/4”      20     BSPT        BT
             Specify in mm
                                                                                                                  1”       25     JIS-PF      PF
                                                                                                                 M20     M20      JIS-PT      PT
         STEM MATERIAL
                                                                                                                                    Gas       GS
  310 SS310         S4S SS304
                                                                                                                                    R         RR
  S6S SS316         600 Inconel 600
                                                                                                                                    Rp        RP
                                                                                                                                 Pitch 1.5     C
                                                                                            e.g. For 1/2"NPT(M), Code: T15NTM
                                                                                                 For M20x1.5 (F), Code: TM20CF
                                                                                                                                   CAPILLARY
                                                                                                           4AR(*)     SS 316 Capillary, SS 304 Armoured
                                                                                                           4PV(*)     SS 316 Capillary, SS 304 Armoured+PVC Covered
                                                                                                           6AR(*)     SS 316 Capillary, SS 316 Armoured
                                                                                                           6PV(*)     SS 316 Capillary, SS 316 Armoured+PVC Covered
                                                                                                           NIL         Not Applicable for BTS-R type.
                                                                                                         * Specify the length of Capillary in Meters.
                                                               Sample Model Code: BTS-R-V-WA-W13-S6L-S10-300-S6S-NIL-T15NTM-(20-200)-DGC-100-FD-L
                    The recommendations made in this catalogue are to be used as intended guide. No guarantee of material can be undertaken since other
                                                                                                                                                                                10/17 REV.: 00
                    factors may affect the performance. We reserve the right to change the specifications mentioned in this catalogue without any notice as
                      improvements & development is a continuous process at “General”. Responsibility of typographical errors is specifically disclaimed.
www.generalinstruments.co.in                                                         219                                                               www.general-gauges.com