Réf.
IC 07/A
LD SC - 05-2012
Marine Diesel Generators
4 strokes Diesel engine, direct injection
Power definition
Standard ISO 3046/1 - 1995 (F)
Reference conditions
Ambiant tempeature 25 °C / 77 ° F
Barometric pressure 100 kPa
Relative humidity 30 %
Raw water temperature 25 °C / 77 ° F
Fuel oil
Relative density 0,840 ± 0,005
Lower calorific power 42 700 kJ/kg
Consumption tolerances ±5%
Air inlet limit de temperature 35 °C / 95 °F
Not contractual picture
Electrical power
Power in kVA declared at pf 0.8
GENERAL DATA
Models Nb cyl Arrangement Bore (mm) Stroke (mm) Swept vol. (l) Flywheel housing
4 W105S 4 in line 105 130 4.50 SAE 3
6 W105S 6 in line 105 130 6.75 SAE 3
6 W126S 6 in line 126 155 11.56 SAE 1
6 M19.3 6 in line 126 155 11.56 SAE 1
6 M26.2 6 in line 150 150 15.90 SMB
8 M26.2 8 in V 150 150 21.20 SAE 0
12 M26.2 12 in V 150 150 31.80 SAE 0
MAXIMUM RATING TABLE
COP PRP LTP
kWe kVA kWe kVA kWe kVA
50 Hz 68 85 68 85 76 95
4 W105S
60 Hz 84 105 84 105 92 115
50 Hz 120 150 120 150 132 165
6 W105S
60 Hz 132 165 132 165 148 185
50 Hz 264 330 264 330 300 375
6 W126S
60 Hz 280 350 280 350 308 385
50 Hz 320 400 320 400 344 430
6 M19.3
60 Hz 360 450 360 450 400 500
50 Hz 304 380 336 420 368 460
6 M26.2
60 Hz 344 430 344 430 - -
50 Hz 400 500 440 550 488 610
8 M26.2
60 Hz 464 580 464 580 512 640
50 Hz 613 765 676 845 740 925
12 M26.2
60 Hz 700 875 700 875 772 965
Continuous power (COP) Prime running power (PRP) Limited time running power (LTP)
Rated load without time or load Variable load with mean power calculated on Variable load with mean power calculated on
factor limitation 250 running hours 250 running hours
No restriction on use if mean power ≤ 75% of No overload
nominal power Typical hours per year 500 hours (with mean
Total operating time at 100% nominal power power ≤ 85% of rated power)
shall not exceed 500 hours per year Total operating time at 100% rated power shall
10% overload available 1 hour each 12 hours not exceed 25 hours per year
Maximum continuous running time at 100%
rated power: 1 hour each 12 hours
3 PHASES SYNCHRONOUS GENERATOR OPTIONAL EQUIPMENTS (extract)
Frequency 50/60 Hz - 4 poles Cooling by keel cooling
Insulation / Heating class H/H High efficiency air filter
Voltage regulation Electronic Exhaust silencer
Excitation Brushless Water injection type exhaust elbow
Protection / Impregnation IP23 / Marine Remote control panel
Bearing Sealed, life lubricated
SPECIFIC FUEL CONSUMPTION
PRP 100% PRP 75% PRP 50% PRP
HZ kVA kWe kWm g/kWh kWm g/kWh kWm g/kWh
50 85 68 75 194 56 196 38 205
4 W105S
60 105 84 92 198 69 197 46 213
50 150 120 129 193 97 194 65 204
6 W105S
60 170 136 145 204 109 207 73 220
50 340 272 290 198 218 201 145 204
6 W126S
60 350 280 300 205 225 206 150 209
50 400 320 330 199 248 198 165 208
6 M19.3
60 450 360 380 202 285 194 190 201
50 420 336 355 201 266 204 178 213
6 M26.2
60 430 344 368 212 276 212 184 224
50 555 444 473 210 355 211 237 215
8 M26.2
60 580 464 491 217 368 218 246 226
50 745 596 710 200 533 201 355 206
12 M26.2
60 875 700 736 205 552 209 368 218
FUEL CONSUMPTION PERFORMANCES (l/h)
Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
DIMENSIONS
kVA kVA
A B C Kg (dry)
50 Hz 60 Hz
4 W105S 85 105 1 680 870 1 285 1 100
6 W105S 100 / 150 120 / 170 2 187 800 1 216 1 500
C
170 / 260 205 / 300 2 584 994 1 619 2 145
6 W126S
270 - 340 325 / 350 2 726 994 1 619 2 371
6 M19.3 400 450 3 239 994 1 320 3 025
6 M26.2 420 430 3 043 1 164 1 414 3 550
A B 8 M26.2 555 580 2 996 1 482 1 575 4 585
12 M26.2 875 875 3 878 1 456 1 575 6 130
Société Internationale des Moteurs Baudouin
Technoparc du Brégadan - CS 50001 - 13711 Cassis Cedex - France - tél. +33 488 688 500 - fax +33 488 588 501 - www.moteurs-baudouin.com