Logic Combi C User Guide
Logic Combi C User Guide
LOGIC COMBI C
   24 30 35
  When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
  specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com
  where you can download the relevant information in PDF format.
  For alternative languages in our User Guides please visit our website www.idealboilers.com.
February 2018
UIN 213972 A06
                                                                                            1.      INTRODUCTION
CONTENTS                                                                                    The Logic Combi C range is a combination boiler providing both
                                                                                            central heating and instantaneous domestic hot water. Featuring
1. Introduction ............................................................... 2           full sequence automatic ignition and fan assisted combustion.
       Safety.......................................................................... 2   Due to the high efficiency of the boiler, condensate is produced from
                                                                                            the flue gases and this is drained to a suitable disposal point through
       Electricity Supply......................................................... 2        a plastic waste pipe at the base of the boiler. A condensate ‘plume’
       Important Notes........................................................... 2         will also be visible at the flue terminal.
2. Boiler Operation........................................................ 3
       Controls Diagram........................................................ 3           SAFETY
       To Start the Boiler........................................................ 3        Current Gas Safety (Installation & Use) Regulations or
       Operation Modes......................................................... 3           rules in force.
       Preheat Domestic Hot Water....................................... 3                  In your own interest, and that of safety, it is the law that this
                                                                                            boiler must be installed by a Gas Safe Registered Engineer, in
       Control of Water Temperature..................................... 3                  accordance with the above regulations.
       Efficient Heating System Operation............................ 4                     In IE, the installation must be carried out by a Registered Gas Installer
       Weather Compensation............................................... 4                (RGII) and installed in accordance with the current edition of I.S. 813
                                                                                            “Domestic Gas Installations”, the current Building Regulations and
       Boiler Frost Protection................................................. 4           reference should be made to the current ETCI rules for electrical
       Boiler Restart............................................................... 4      installation.
       Mains Power Off.......................................................... 4          It is essential that the instructions in this booklet are strictly
                                                                                            followed, for safe and economical operation of the boiler.
3. System Water Pressure............................................ 4
                                                                                            ELECTRICITY SUPPLY
4. Condensate Drain...................................................... 5
                                                                                            This appliance must be earthed.
5. General Information.................................................. 5                  Supply: 230 V ~ 50 Hz. The fusing should be 3A.
       Boiler Pump................................................................. 5
       Minimum Clearances................................................... 5
       Expansion.................................................................... 5      IMPORTANT NOTES
       Escape of Gas............................................................. 5         •    This appliance must not be operated without the casing
                                                                                                 correctly fitted and forming an adequate seal.
       Cleaning...................................................................... 5
                                                                                            •    If the boiler is installed in a compartment then the compartment
       Maintenance................................................................ 5
                                                                                                 MUST NOT be used for storage purposes.
6. Points for the Boiler User......................................... 6
                                                                                            •    If it is known or suspected that a fault exists on the boiler then
       Troubleshooting........................................................... 6              it MUST NOT BE USED until the fault has been corrected by
7. Normal Operation Display Codes............................ 7                                  a Gas Safe Registered Engineer or in IE a Registered Gas
                                                                                                 Installer (RGII).
8. Fault Codes................................................................ 8
                                                                                            •    Under NO circumstances should any of the sealed components
                                                                                                 on this appliance be used incorrectly or tampered with.
             All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the
                  Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500.
    Ideal Boilers is a member of the Benchmark scheme and fully supports the aims of the
    programme. Benchmark has been introduced to improve the standards of installation and
    commissioning of central heating systems in the UK and to encourage the regular servicing of all
    central heating systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
2                                                                                                                                                                User’s
2.     BOILER OPERATION
  Legend
  A. Domestic Hot Water Temperature Knob
  B. Central Heating Temperature Knob                                                                                                 BOILER
  C. Mode Knob                                                                                                                  e
                                                                                                                                       OFF
                                                                                                              ºC
  D. Boiler Status Display
  E. Burner ‘on’ Indicator                                                                    HOT WATER
                                                                                              PREHEAT
                                                                                              ON
  F. Preheat On Off button                                              MIN           MAX                             MIN       MAX
J A D F G E B H C
Note: If the boiler fails to light after five attempts the fault code             Due to system variations and seasonal temperature fluctuations
   will be displayed (refer to Fault Code page).                                  domestic hot water flow rates/temperature rise will vary, requiring
                                                                                  adjustment at the tap : the lower the flow rate the higher the
                                                                                  temperature, and vice versa.
               ‘   ’
EFFICIENT HEATING SYSTEM OPERATION                                    3. SYSTEM WATER PRESSURE
The boiler is a high efficiency, condensing appliance which will      The system pressure gauge indicates the
automatically adjust its output to match the demand for heat.         central heating system pressure. If the pressure
Therefore gas consumption is reduced as the heat demand is            is seen to fall below the original installation
reduced.                                                              pressure of 1-2 bar over a period of time and
The boiler condenses water from the flue gases when                   continue to fall then a water leak may be
operating most efficiently. To operate your boiler efficiently        indicated. In this event re-pressurise the system
(using less gas) turn the central heating temperature knob            as shown below. If unable to do so or if the
(B) to the ‘ ‘ position or lower. In winter periods it may be         pressure continues to drop a Gas Safe Registered Engineer or in IE
necessary to turn the knob towards the ‘MAX’ position to meet         a Registered Gas Installer (RGII) should be consulted.
heating requirements. This will depend on the house and               THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS
radiators used.                                                       REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION.
Reducing the room thermostat setting by 1ºC can reduce gas            To Top up the system :-
consumption by up to 10%.
                                                                      1. Ensure both A & B handles (blue) are in closed position (as
                                                                         shown below)
WEATHER COMPENSATION                                                  2. Remove the plug and cap and retain.
When the Weather Compensation option is fitted to the system          3. Connect the filling loop to the Domestic Hot Water (DHW) inlet and
then the central heating temperature knob (B) becomes                    tighten. Also ensure that the other end of filling loop is hand tight.
a method of controlling room temperature. Turn the knob
clockwise to increase room temperature and anti-clockwise              Starting Position                                   Domestic Hot Water
to decrease room temperature. Once the desired setting has                                                                  (DHW) Inlet Valve
been achieved, leave the knob in this position and the system
will automatically achieve the desired room temperature for all
outside weather conditions.
                                                                          Filling                                      A
                                                                          Loop
BOILER FROST PROTECTION
The boiler is fitted with frost protection that operates in all                          Cap               Plug
modes, provided the power supply to the boiler is always                                             B
turned on. If the water in the boiler falls below 5ºC, the frost
protection will activate and run the boiler to avoid freezing.
The process does not guarantee that all other parts of the
system will be protected.
                                                                         Filling Loop
If a system frost thermostat has been installed, the boiler must
                                                                        Handle (Blue)
be set in winter mode, ‘     ’, for the system frost protection to
run.
If no system frost protection is provided and frost is likely
                                                                       Filling Position
during a short absence from home it is recommended to leave
the system heating controls or built in programmer (if fitted)                                     Cap
switched on and run at a reduced temperature setting. For                                Plug
longer periods, the entire system should be drained.
                                                                              Filling
                                                                              Loop
BOILER RESTART
To restart the boiler, when directed in the listed fault codes (see                                          A
section 8) press the restart button (G). The boiler will repeat its
ignition sequence. If the boiler still fails to start consult a Gas
Safe Registered Engineer or an IE Registered Gas Installer                                     B
(RGII).
4                                                                                                                                      User’s
4.      CONDENSATE DRAIN                                                   5.     GENERAL INFORMATION
This appliance is fitted with a siphonic condensate trap system            BOILER PUMP
that reduces the risk of the appliance condensate from freezing.           The boiler pump will operate briefly as a self-check once every 24
However should the condensate pipe to this appliance freeze,               hours, regardless of system demand.
please follow these instructions:
a. If you do not feel competent to carry out the defrosting
   instructions below please call your local Gas Safe Registered
   installer for assistance.                                               MINIMUM CLEARANCES
b. If you do feel competent to carry out the following instructions        Clearance of 165mm above, 100mm below, 2.5mm at the sides
   please do so with care when handling hot utensils. Do not attempt       and 450mm at the front of the boiler casing must be allowed for
   to thaw pipework above ground level.                                    servicing.
If this appliance develops a blockage in its condensate pipe, its          Bottom Clearance
condensate will build up to a point where it will make a gurgling          Bottom clearance after installation can be reduced to 5mm.
noise prior to locking out an “L 2” fault code. If the appliance is
restarted it will make a gurgling noise prior to it locking out on a       This must be obtained with an easily removable panel, to enable
failed ignition “L 2” code.                                                the system pressure gauge to be visible and to provide the 100mm
                                                                           clearance required for servicing.
To unblock a frozen condensate pipe;
1. Follow the routing of the plastic pipe from its exit point on the
   appliance, through its route to its termination point.
     Locate the frozen blockage. It is likely that the pipe is frozen at   EXPANSION
     the most exposed point external to the building or where there        NOTE. If a water meter is fitted into the incoming water mains
     is some obstruction to flow. This could be at the open end of         there may be a requirement for a domestic hot water expansion
     the pipe, at a bend or elbow, or where there is a dip in the pipe     vessel Kit. Contact a Gas Safe Registered Engineer or in IE a
     in which condensate can collect. The location of the blockage         Registered Gas Installer (RGII).
     should be identified as closely as possible before taking further
     action.
2. Apply a hot water bottle, microwaveable heat pack or a warm
   damp cloth to the frozen blockage area. Several applications            ESCAPE OF GAS
   may have to be made before it fully defrosts. Warm water can            Should a gas leak or fault be suspected contact the National Gas
   also be poured onto the pipe from a watering can or similar.            Emergency Service without delay. Telephone 0800 111 999.
   DO NOT use boiling water.
                                                                           Ensure that;
3. Caution when using warm water as this may freeze and cause              - All naked flames are extinguished
   other localised hazards.                                                - Do not operate electrical switches
4. Once the blockage is removed and the condensate can flow freely,        - Open all windows and doors
   restart the appliance. (Refer to “To Start the boiler”)
5. If the appliance fails to ignite, call your Gas Safe Registered
   engineer.
                                                                           CLEANING
Preventative solutions
                                                                           For normal cleaning simply dust with a dry cloth. To remove stubborn
During cold weather, set the central heating temperature knob
                                                                           marks and stains, wipe with a damp cloth and finish off with a dry
(B) to maximum (must return to original setting once cold spell is
                                                                           cloth. DO NOT use abrasive cleaning materials.
over).
Place the heating on continuous and turn the room thermostat
down to 15ºC overnight or when unoccupied. (Return to normal
after cold spell).                                                         MAINTENANCE
                                                                           The appliance should be serviced at least once a year by a Gas
                                                                           Safe Registered Engineer or in IE a Registered Gas Installer
                                                                           (RGII).
User’s                                                                                                                                       5
6.       POINTS FOR THE BOILER USER
Note. In line with our current warranty policy we would ask that you check through the following guide to identify any
problems external to the boiler prior to requesting a service engineer’s visit. Should the problem be found to be other
than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not
gained by the engineer.
TROUBLESHOOTING
 Check the mains power is turned            Check the mains power is turned
 on and ensure mode knob (C) is             on and ensure mode knob (C) is               Check the mains power is turned
 in the summer or winter position                in the winter position                  on and ensure mode knob (C) is
                                                                                              in the winter position
6                                                                                                                          User’s
  7.               NORMAL OPERATION DISPLAY CODES
00 The boiler is in standby operation awaiting either a central heating call or hot water demand.
                                       The boiler has a call for central heating but the appliance has reached the desired
               54       o
                         C             temperature set on the boiler.
                                       The boiler has a call for hot water but the appliance has reached the desired temperature set on
               54       o
                         C             the boiler.
                   54   o
                            C
       HOT WATER
       PREHEAT
       ON
                   PH   o
                            C
-- heating operation.
User’s                                                                                                                                     7
8.     FAULT CODES
     DISPLAY CODE ON BOILER     DESCRIPTION                                      ACTION
        F1                    Low Water Pressure               Check system water pressure is between 1 & 1.5bar on the system pressure gauge. To
                                                               re-pressurise the system see Section 3. If the boiler still fails to operate then please contact
                                                               Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the
                                                               warranty period. In IE contact a Registered Gas Installer (RGII).
                              Flame Loss
        F2
                                                               1. Check other gas appliances in the house are working to confirm a supply is present in
                                                                  the property.
                                                               2. If other appliances do not work or there are no other appliances, check the gas supply
                                                                  is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then
                                                                  please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer
                                                                  if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
        F3                    Fan Fault                        Restart the appliance - if the boiler fails to operate then please contact Ideal (if under
                                                               warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
                                                               period. In IE contact a Registered Gas Installer (RGII).
Flow Thermistor Restart the appliance - if the boiler fails to operate then please contact Ideal (if under
        F5           L5
                              Return Thermistor                Restart the appliance - if the boiler fails to operate then please contact Ideal (if under
                                                               warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
                                                               period. In IE contact a Registered Gas Installer (RGII).
        F7
                              Low Mains Voltage                Contact a qualified electrician or your electricity provider.
Unconfigured PCB Unconfigured/faulty PCB or gas valve short circuit. Please contact Ideal (if under
Flow Temperature Overheat Check system water pressure is between 1 & 1.5bar on the system pressure gauge.
        L1                    or No Water Flow                 To re-pressurise the system see Section 3. If the boiler fails to operate then please contact
                                                               Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the
                                                               warranty period. In IE contact a Registered Gas Installer (RGII).
        L2                                                     2. Check other gas appliances in the house are working to confirm a supply is present in
                                                                  the property.
                                                               3. If other appliances do not work or there are no other appliances, check the gas supply
                                                                  is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then
                                                                  please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer
                                                                  if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
        L6                    False Flame Lockout              Restart the appliance - if the boiler fails to operate then please contact Ideal (if under
                                                               warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
                                                               period. In IE contact a Registered Gas Installer (RGII).
5 Boiler Resets in 15 minutes 1. Turn electrical supply to boiler off and on.
        LC                                                     2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively
                                                                  a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a
                                                                  Registered Gas Installer (RGII).
Negative Differential If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively
        FA                    Flow/Return Thermistor           a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a
                                                               Registered Gas Installer (RGII).
        FU
                              Flow/Return Differential >       If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively
                              50°C                             a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a
                                                               Registered Gas Installer (RGII).