0% found this document useful (0 votes)
44 views1 page

Railway Land Boundary Plan

The document outlines a standard track crossing plan for laying optical fiber cable between railway stations. Key details include: 1. The cable will be laid horizontally under the railway tracks using a boring method from a pit outside the railway boundary. 2. A 100mm diameter high density polyethylene, cast iron or mild steel casing pipe will protect the 20mm OFC cable where it passes under the railway boundary. 3. Cable indicating boards will be fixed at the railway boundaries and any damage to underground cables or pipelines will be borne by the party performing the work.

Uploaded by

Yogesh Bhardwaj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views1 page

Railway Land Boundary Plan

The document outlines a standard track crossing plan for laying optical fiber cable between railway stations. Key details include: 1. The cable will be laid horizontally under the railway tracks using a boring method from a pit outside the railway boundary. 2. A 100mm diameter high density polyethylene, cast iron or mild steel casing pipe will protect the 20mm OFC cable where it passes under the railway boundary. 3. Cable indicating boards will be fixed at the railway boundaries and any damage to underground cables or pipelines will be borne by the party performing the work.

Uploaded by

Yogesh Bhardwaj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

STANDARD TRACK CROSSING PLAN FOR OFC IN BETWEEN STATIONS 1. EXISTING WORK SHOWN IN BLACK.
2. PROPOSED WORK SHOWN IN RED.
3. M.S / H.D.P.E / C.I CASING PIPE TO BE PROVIDED IN BETWEEN RLY.

4. THE WORK WILL BE DONE BY HORIZONTAL BORING METHOD UNDER THE RLY.

APPLICATION ID NWR-JP-2024-WL-84 TOTAL LENGTH BETWEEN RLY LAND BOUNDARY = ( 50 )M


TRACK THROUGHOUT RLY. BOUNDARY AND PIT FOR BORING WILL BE MADE

OUTSIDE RLY. BOUNDARY.

5. CABLE INDICATING BOARDS TO BE FIXED AT RLY. BOUNDARIES BY THE PARTY.

B
( 20 )MM OFC CABLE 6. ANY DAMAGE IN U/G CABLE.PIPE LINE,DRAINS ETC. WILL BE BORNE BY THE
PARTY.

7. THE WORK TO BE DONE IM THE PRESENCE OF S&T SUPERVISOR.


RAILWAY LAND BOUNDARY

8. LAYING OF PROPER EARTHING ARRANGEMENT TOBE DONE UNDER RLY.


RAIL LEVEL-100.00(ASSUMED)
ELECT.SUPERVISOR.

(K.M-CH62/700 ) (K.M -CH62/800)


** PARTY SHOULD FILL ALL THE DETAILS CORRECTLY IN CONSULTATION WITH
FORM. LEVEL-( 99.33 )
( 20.5 ) M CONCERNED RAILWAY SUPERVISOR TO AVOID REJECTION OF APPLICATION.

C.L. OF ( 20 ) LINE

TO (SIRAS) ( )M TO (BANSATHALI NIWAI )


GROUND LEVEL-( 98.33 )
( 50 ) M
C.L. OF ( 30 ) LINE

MIN 2000 MM (K.M- 62/700) (K.M-62/800)


PROPOSED ( 2000 )MM
( 25 )M
TOP OF CASING PIPE = ( 96.33 ) ( 100 ) MM DIA. HDPE / C.I / M.S
CASING PIPE IN BETWEEN RLY.
BOUNDARY
( 100 ) MM DIA. HDPE / C.I / M.S ( )MM OFC CABLE
RAILWAY LAND BOUNDARY
CASING PIPE IN BETWEEN RLY.
CABLE INDICATING BOARD
BOUNDARY ON BOTH SIDES

A
TEMPORARY PIT
DRM JAIPUR
SECTION AT A-B TEMPORARY PIT

ADRM/INFRA
SITE PLAN
(SCALE: 1:1000)
Sr.DEN/C

Sr.DEN/( )

C.L. OF ( ) LINE C.L. OF ( ) LINE

( 25 ) M ( )M ( 25 ) M DEN/LAND/G
RAILWAY LAND BOUNDARY
RAILWAY LAND

RAIL LEVEL-100.00(ASSUMED) BOUNDARY


DIVISIONAL OFFICERS

FORM. LEVEL- ( 99.33 )


CABLE INDICATING BOARD
(JAIPUR) D I V I S I O N- ( NWR ) RAILWAY

GROUND LEVEL ( 98.33 )


GROUND LEVEL ( 98.33 )
( 3670 ) MM

C.C. BED BLOCK


600X600X300 C.C. BED BLOCK
MIN 2000 MM 600X600X300 WAY LEAVE FACILITIES FOR LAYING OF (100)
PROPOSED (2000)MM ( 100 ) MM DIA. HDPE / C.I / M.S
MM DIA. U/G HDPE /C.I / M.S CASING PIPE
CASING PIPE IN BETWEEN RLY.
BOUNDARY FOR PASSING OF (20) MM OFC CABLE AT

KM: (62/700) BET: ( SIRAS ) AND


( 20 )MM OFC CABLE

(50) M FEASIBILITY OF THE PROPOSAL HAS BEEN CHECKED


KM: (62/800)( BANSATHALI NIWAI ) RLY.
AND FOUND FEASIBLE AS SHOWN IN PLAN.
STN.

SECTION AT A-B
APPLICANT PARTY
ADEN/(LINE/JP)
(NOT TO SCALE) (WITH STAMP)

You might also like