0% found this document useful (0 votes)
124 views2 pages

Unidirectional Opening Sensor For Automatic Sliding Doors: Description

This document provides a user's guide for an automatic sliding door sensor with the following key details: 1. It describes the purpose and basic functions of the sensor including detecting motion to trigger automatic doors. 2. The technical specifications are listed including details like the operating frequencies, power levels, voltage requirements, mounting heights, temperature ranges, and dimensions. 3. Instructions on applicable directives and compliance with European standards are provided.

Uploaded by

Milutin Jankovic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views2 pages

Unidirectional Opening Sensor For Automatic Sliding Doors: Description

This document provides a user's guide for an automatic sliding door sensor with the following key details: 1. It describes the purpose and basic functions of the sensor including detecting motion to trigger automatic doors. 2. The technical specifications are listed including details like the operating frequencies, power levels, voltage requirements, mounting heights, temperature ranges, and dimensions. 3. Instructions on applicable directives and compliance with European standards are provided.

Uploaded by

Milutin Jankovic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ENGLISH

Unidirectional opening sensor


for automatic sliding doors
User’s Guide for product version 0100 and higher
See product label for serial number
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOUR PRINTING

DESCRIPTION

1. radar antenna
2. potentiometer
3. cover
4. main connector 3
5. DIP-switch

4
1
5

2
©BEA | Original instructions | 42.7808 / V1 - 06.13

TECHNICAL SPECIFICATIONS
Technology: microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm²
Detection mode: motion
Min. detection speed: 5 cm/s (measured in sensor axis)
Supply voltage: 12 V to 24 V AC ±10%; 12 V to 24 V DC +30% / -10%
Mains frequency: 50 to 60 Hz
Max power consumption: <2W
Output: relay (free of potential change-over contact)
Max. contact voltage: 42 V AC/DC
Max. contact current: 1 A (resistive)
Max. switching power: 30 W (DC) / 60 VA (AC)
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA.BE
Mounting height: from 1.8 m to 3 m
Degree of protection: IP54
BEA hereby declares that the VIO-M1 is in conformity with the basic requirements and the other relevant provisions Temperature range: from -20 °C to + 55 °C
of the directive 1999/5/EC.
Angleur, June 2013 Pierre Gardier, Authorized representative and responsible for technical documentation Dimensions: 180 mm (L) x 58 mm (H) x 50 mm (W)
The complete declaration of conformity is available on our website: www.bea-pedestrian.be Tilt angles: 15° to 45° vertical; -15° to +15° lateral
Applicable directives: R&TTE 1999/5/EC
For EC countries: according to the directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
Specifications are subject to changes without prior notice. Measured in specific conditions.
TROUBLESHOOTING
1 MOUNTING & WIRING

1 2 12-24 V
COM
The door remains The sensor power is off. 1 Check the wiring and the power supply.
closed.
NO-NC
The LED is OFF.

The door does not Improper output 1 Change the output configuration setting on
react as expected. configuration on the sensor. each sensor connected to the door operator.

The door closes and The sensor is disturbed by 1 Make sure the sensor is fixed properly.
Apply the mounting template. Fix the sensor firmly and
opens constantly. the closing of the door or 2 Make sure the detection mode is unidirectional.
Drill 1 hole for the cable and connect the cable.
vibrations caused by the 3 Increase the antenna angle.
pull it through.
door motion. 4 Increase the immunity filter.
Drill 2 holes for the screws.
5 Reduce the field size.

The door opens for It rains and the sensor 1 Make sure the detection mode is unidirectional.
no apparent reason. detects the motion of the 2 Increase the immunity filter.
2 ADJUSTMENTS rain drops. 3 Use a rain accessory.

In highly reflective 1 Change the antenna angle.


environments, the sensor 2 Decrease the field size.
DIP 4
DIP-SWITCH

DIP 1 DIP 2 DIP 3


detects objects outside of its 3 Increase the immunity filter.
DETECTION MODE OUTPUT CONFIG. PRM-MODE IMMUNITY FILTER
detection field.

In airlock vestibules, 1 Change the antenna angle.


ON unidirectional NC for PRM* high
the sensor detects the 2 Increase the immunity filter.
movement of
OFF bidirectional NO normal normal the opposite door.

*PRM= persons with reduced mobility


DIP 1 needs to be ON for this function
FIELD SIZE

MIN MAX
2.2 m 2.2 m

vertical angle: 30°

SAFETY INSTRUCTIONS
ANGLE

- Test the good functioning of the installation before leaving the premises.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer
2.2 m 2.2 m of the sensor.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualified personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic components, avoid vibrations, do not cover the sensor and avoid proximity to neon lamps or moving
objects.
field size: max - The door control unit and the door cover profile must be correctly earthed.