ENGLISH
FALCON / -XL
Opening sensor for automatic industrial doors*
FALCON: for normal to high mounting (3.5 - 7 m)
FALCON XL: for low mounting (2 - 3.5 m)
DESCRIPTION
1. push buttons
2. front face
3. radar antenna
4. angle indication
5. bracket
6. cable
1 4
2
3 5
6
TECHNICAL SPECIFICATIONS
Technology: microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm²
Detection mode: motion
Detection zone: FALCON: 4 x 5 m ; FALCON XL: 4 x 2 m (typical at 30° and field size 9)
Min. detection speed: 5 cm/s**
Supply voltage: 12 V to 24 V AC ±10 %; 12 V to 24 V DC +30 % / -10%
Mains frequency: 50 to 60 Hz
Max power consumption: <2W
Output: relay (free of potential change-over contact)
Max. contact voltage: 42 V AC/DC
Max. contact current: 1A (resistive)
Max. switching power: 30 W (DC) / 42 VA (AC)
LED-signal: red: detection state, parameter indication; green: value indication
Mounting height: FALCON: 3.5 m - 7m; FALCON XL: 2 m - 3.5 m
Degree of protection: IP65
Temperature range: from -30 °C to + 60 °C
Dimensions: 127 mm (L) x 102 mm (H) x 96 mm (W)
Tilt angles: 0° to 180° vertical
Materials: ABS and polycarbonate
Weight: 400 g
Cable length: 10 or 15 m
Norm conformity: EN 300 440-2 V1.4.1; EN 301 489-1 V1.9.2;
EN 301 489-3 V1.6.1; EN 62311; EN 62479
Specifications are subject to changes without prior notice.
* Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
** Measured in optimal conditions
1 MOUNTING & WIRING
1 2 3
GN
12-24 V
BN AC-DC
WH
COM
YE
NO
GY
NC
Remove the bracket Position the sensor on the Connect the wires to the door
from the sensor. Drill 2 holes bracket and fasten the screws controller. Choose between NO
accordingly. Fix the bracket firmly. and NC contact.
firmly.
2 DETECTION FIELD ADJUSTMENTS
1 CEILING 2
0-9
WALL
Adjust the angle of the sensor to position the detection field. Adjust the field size with the
remote control or the push
buttons.
FALCON FALCON FALCON XL
Mounting height: 5 m Mounting height: 3.5 m Mounting height: 2.5 m
All detection field dimensions were measured in optimal conditions and with field size value 9.
3 DETECTION FILTER (REJECTION MODE)
Choose the right detection filter for your application with the remote control or the push buttons:
Detection of all targets Detection only of vehicles moving towards the sensor*
(pedestrians and parallel traffic are detected) (pedestrians and parallel traffic are not detected + disturbances are filtered)
Value recommendations according to angle and height:
1-6 1 = no specific filter
7 m - 3.5 m 2.5 m Always check if the chosen
15° 3 3 value is optimal for the
2 = filter against disturbances 4 4 application.
30°
(recommended in case of vibrations, rain etc.) 45° 5 4
The object size and nature
can influence the detection.
+45° 6 5
XL
FALCON * The vehicle detection filter increases the response time of the sensor.
MOUNTING TIPS
Avoid vibrations. Do not cover the sensor. Avoid proximity to neon Only open the sensor
lamps or moving objects. when the cable needs
to be replaced.
DIMENSIONS (in mm)
Wall mounting Ceiling mounting Bracket dimensions
POSSIBLE SETTINGS BY REMOTE CONTROL
FIELD SIZE XXS XS S > > > > L XL XXL
HOLD-OPEN TIME 0.5 s 1s 2s 3s 4s 5s 6s 7s 8s 9s
OUTPUT A P
A = active output (relay active when detection)
P = passive output (relay active when no detection)
CONFIGURATION
bi uni uni bi = two-way detection
DETECTION MODE AWAY uni = one-way detection towards sensor
uni AWAY = one-way detection away from sensor
DETECTION FILTER 1 2 3 4 5 6
FACTORY VALUES RESETTING TO FACTORY VALUES:
POSSIBLE SETTINGS BY PUSH BUTTONS
TO START OR END AN ADJUSTMENT SESSION, press and hold either push button until the LED flashes or
stops flashing.
Parameter n° Value (factory values)
TO SCROLL THROUGH THE 1 FIELD SIZE (7)
PARAMETERS, press
the right push button. 2 HOLD-OPEN TIME (0)
3 OUTPUT CONFIGURATION (1)
TO CHANGE THE VALUE OF
4 DETECTION MODE (2)
THE CHOSEN PARAMETER,
press the left push button. 5 DETECTION FILTER (1)
TO RESET TO FACTORY VALUES, press and hold both push buttons until both LEDs flash.
FALCON
ACCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you do not know the access code, cut and restore the power supply. During 1 minute, you can access the sensor
without introducing any access code.
TROUBLESHOOTING
The door remains The sensor power is off. 1 Check the wiring and the power supply.
closed.
The LED is OFF.
The door does not Improper output 1 Check the output configuration setting on each
react as expected. configuration on the sensor. sensor connected to the door operator.
The door opens The sensor is disturbed 1 Make sure the sensor is fixed properly.
and closes by the door motion or 2 Make sure the detection mode is unidirectional.
constantly. vibrations caused by the 3 Increase the tilt angle.
door motion. 4 Increase the detection filter value.
5 Reduce the field size.
The door opens for The sensor detects raindrops 1 Make sure the detection mode is unidirectional.
no apparent reason. or vibrations. 2 Increase the detection filter value.
In highly reflective 1 Change the antenna angle.
environments, the sensor 2 Decrease the field size.
detects objects outside of its 3 Increase the detection filter value.
detection field.
©BEA | Original instructions | 42.7330 / V5 - 01.17
The vehicle detection The chosen value is not 1 Increase the detection filter value.
filter is used, but optimal for this application. 2 Decrease the sensor angle.
pedestrians are still 3 Increase the installation height.
detected. 4 Make sure the detection mode is unidirectional.
The LED The sensor needs an access 1 Enter the right access code.
flashes quickly code to unlock. 2 If you do not know the access code, cut the power
after unlocking. supply and restore it to access the sensor and
change the access code or delete it.
The sensor does The remote control 1 Check the batteries and change them
not respond to the batteries are weak or if necessary.
remote control. improperly installed.
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with
applicable national and international regulations and standards on door safety.
Only trained and qualified personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM
BEA hereby declares that the FALCON is in conformity with the basic requirements and the other
relevant provisions of the directives 2014/53/EU and 2011/65/EU.
The complete declaration of conformity is available on our website.
Only for EC countries: According the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)