0% found this document useful (0 votes)
54 views2 pages

Instruction Manual For HC005S 2

The document is a user manual for the Hytronik Microwave Motion Sensor Model No.: HC005S, detailing installation, settings, and troubleshooting. It includes specifications such as detection range, hold time, and daylight sensor settings, along with wiring instructions for various configurations. The manual also provides guidance on addressing common issues that may arise during operation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views2 pages

Instruction Manual For HC005S 2

The document is a user manual for the Hytronik Microwave Motion Sensor Model No.: HC005S, detailing installation, settings, and troubleshooting. It includes specifications such as detection range, hold time, and daylight sensor settings, along with wiring instructions for various configurations. The manual also provides guidance on addressing common issues that may arise during operation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HYTRONIK INDUSTRIAL LIMITED CHINA FACTORY

Room D, 10/f, Tower A, Billion Center, 1 wang Kwong Road, 3rd Floor, block C, complex building, 155#, Bai'gang road south,
Kowloon Bay, Kowloon, Hongkong Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
T: 00852-35197525 F: 00852-30116936 Tel:86-752-2772020 F:86-752-2777877
E: info@hytronik.com E: info@hytronik.com W:www.hytronik.com

User Manual of Microwave Motion Sensor


Super compact version Model No.:HC005S

   Daylight sensor


LED indication
 Antenna module

Detection area
Hold-time
<0.2mW Daylight threshold Installation hole

    

<0.5W
Max. 10 meters in diameter, adjustable Power supply
220-240V out control
5s

2~50LUX, disable
-35 ~ +70°C*
*For usage in -35°C ~ -20°C enviroment, please refer to www.hytronik.com/download ->knowledge ->Microwave Sensors - Precautions
for Product Installation and Operation point 4) for more information.
NOTE:We recommend the mounting distance between sensor to sensor
should be more than 2m to prevent sensors from false-triggering.

0.2mw Approx.1000mw

NOTE:the high-frequency output of this sensor is <0.2mW;approximately just 1‰ of the transmission power of a mobile telephone or
the output of a microwave oven.

1.0

4
Nx2(neutral / 220-240VAC)
L (phase / 220-240VAC)
L’ (switched phase / output)
N

N
Control gear
L

To connect several standard control gear with


N
1 sensor(ON-OFF function),the wiring should be: L
Control gear

L N N L‘
N
Control gear
L
N

With Tridonic switchDIM ballast / driver SwitchDim

( Excel ballast/driver, corridor function) , N


L
Control gear

this sensor can also achieve tri-level


dimming control: SwitchDim
N
Control gear
L
L N N L‘

SwitchDim
N
Control gear
L

1.1 This sensor is suitable for indoor use, and is also designed for installation Max. 6m in height.
* While sensor use with dimming ballast/driver,please keep the sensor antenna module from the ballast/driver and lamp filament
by at least 80mm.
SECTION 2 SETTINGS
Detection range:
This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure. Note
that reducing the sensitivity will also narrow the detection range.
The following settings are available: on
1 2 3
I - Detection range 100%
II – Detection range 75%
III – Detection range 50%
IV – Detection range 30%
V – Detection range 10%
off
Hold time:
This determines the time the fitting remains at 100% level on motion detection and is set with DIP switches at the sensor itself,
refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range.
The following settings are available:
I – Walk test mode 5s 4 5 6
on
II – 30s
III – 1 minute
IV – 5 minutes
V – 10 minutes
VI – 20 minutes
VII– 30 minutes off
Daylight sensor:
This setting holds off the 100% light output should there sufficient daylight and is set using DIP switches at the sensor, refer to
figure. The following settings are available: on
I – Disabled 7 8 9
II – 50 lux
III – 20 lux
IV – 5 lux
V – 2 lux
off
*In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright daylight.

SECTION 3 FUNCTION
Zero-cross relay operation
Designed in the software, sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing through
the relay contact point, and enable the max. load and life-time of the relay.

SECTION 4 TROUBLE SHOOTING

MALFUNCTION CAUSE REMEDY CAUSE REMEDY


Incorrect light-control setting selected Adjust setting
The load will not work Load faulty Replace load
Mains switch OFF Switch ON
The load is always on Continuous movement in the detection zone Check zone setting
The sensor is not mounted for reliably detecting
Securely mount enclosure
movement
The load is on without any identifiable
movement Movement occurred, but not identified by the sensor
(movement behind wall, movement of small object in Check zone setting
immediate lamp vicinity etc.)
Rapid movements are being suppressed to minimise
The load will not work despite movement Check zone setting
malfunctioning or the detection radius is too small