0% found this document useful (0 votes)
30 views2 pages

Motor Checklist

Uploaded by

matsapawesleyt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
30 views2 pages

Motor Checklist

Uploaded by

matsapawesleyt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
$0011 Created by NICO : 28/02/2011 BALTIMORE AIRCOIL COMPANY Baltimore Aicol International nv» Inustepark, Zone A » 2220 Hels-op-den-Berg » Belgium » ww BaimoreAicol.eu Motor Checklist (1S REQUIRED BAC MODEL (") ‘SERIAL NUMBER (*) DELIVERY DATE (*): Description probiem DOES THE PROBLEM OCCUR SINCE STARTUP? (*) IF NOT, HOW MANY OPERATING HOURS DID THE MOTOR RUN WITHOUT A PROBLEM? (*) NAMEPLATE DATA.(): BRAND: VOLTAGE: __ TYPE: CURRENT: _ CONNECTION PROTECTION: __ Nv OF PHASES: RPM: FRECUENCY: POWER: SNe MEASUREMENTS MAKE SURE THE MOTOR IS RUNNING AT FULL SPEED. IF THE MOTOR HAS TWO SPEEDS CHECK BOTH AND TAKE NOTE OF THE MEASUREMENTS, FULL LOAD CURRENT (BELTS INSTALLED): “CURRENT PHASE 1 A VOLTAGE PHASE t “CURRENT PHASE 2 : ‘A VOLTAGE PHASE 2 “CURRENT PHASE 3 : ‘A VOLTAGE PHASE 3 NO LOAD CURRENT (REMOVE BELTS) (CURRENT PHASE 1 “CURRENT PHASE 2: -CURRENT PHASE 3 VOLTAGE PHASE 1: VOLTAGE PHASE 2 VOLTAGE PHASE 3 MAKE SURE THE MOTOR IS SHUT DOWN & ELECTRICALLY DISCONNECTED. “INSULATION BETWEEN GROUND & WINDINGS: MOHM “INSULATION BETWEEN WINDINGS: BETWEEN U8 V: MoHM BETWEEN Ua W: MOHM BETWEEN V 8 W: MoHM - WINDING RESISTANCE OF EACH WINDING (WITH A MILLLOHM METER) WINDING U: nM WINDING v. om WINDING W: nM NET FRECUENCY: Hz |S THERE ONE OF BELOW ACCESSORIES INSTALLED? IF YES WHICH & MEASURE RESISTANCE: YESINO prc nM E-mail info@Battimoredircoilbe » Tel. +3215 2577 00 » Fax +3215 24 47 79 80011 Created by NICO : 28/02/2011 THERMOSTAT =, OHM SPACE HEATER 7 one DOES THE MOTOR RUN WITH ABNORMAL NOISE? YESINO IFYES,LETMOTOR RUN ATFULL SPEED & SUDDENLY CUT MOTORS’ POWER SUPPLY. |S THE NOISE STILL PRESENT WHEN MOTORS SLOWING DOWN? YESINO MECHANICAL IS THE NOISE PRESENT WHEN RUNNING WITH BELTS INSTALLED? YESINO IS THE NOISE PRESENT WHEN RUNNING WITH BELTS REMOVED? YESINO DOES THE MOTORSHAFT TURN FREELY BY HAND? YESINO IS THE COOLING FAN OF THE MOTOR TOUCHING THE COVER? YESINO IF THE NOISE IS COMING FROM THE BEARINGS: NOTE BEARING TEMPEREATURES (FRONTIBACK): ____€ (ifpossibio) NOTE ENVIRONMENT TEMPERATURE: ‘© Urpossble) MEASURE VIBRATION LEVEL: rom (if possible) HOW OFTEN ARE THE BEARINGS GREASED (IF APPLICABLE) ' APPLICATION FANIPUMP | ‘SETTING THERMAL RELAY: A HOW DOES THE MOTOR START: DOL / STAR-DELTA/VFD / SOFT STARTER WHICH DUTY CYCLE DOES THE MOTOR HAVE: 'S1 (CONTINOUSLY WORKING) ‘82 (LIMITED DURATION) IDLE TIME = OTHER DUTY: HOW MANY TIMES DOES THE MOTOR START IN ONE HOUR? fi IS THE MOTOR RUNNING IN THE CORRECT DIRECTION? YESINO | IS THERE ANY PHYSICAL DAMAGE ON THE MOTOR? YESINO IF YES, WHAT: DIAMETER OF THE MOTOR SHEAVE AND MODEL: DIAMETER OF THE FAN SHEAVE AND MODEL: NUMBER OF BELTS: BELT TENSION. ELECTRICAL: HOW IS THE MOTOR CONNECTED? [STAR DELTA/ 25PEED IF A FREQUENCY ORIVE IS USED, WHICH TYPE & MODEL: WHAT IS THE MIN. FRECUENCY: WHAT IS THE MAX, FRECUENCY: TOTAL LENGTH POWER SUPPLY CABLES (FROM VFO TO MOTOR): ARE THERE FILTERS INSTALLED (IF YES WHICH TYPE} [ARE THERE MULTIPLE MOTORS CONNECTED TO 1 VED? YESING | ASOFT STARTER IS USED, WHICH TYPE & MODEL: : | 1S THE MOTOR WIRED ACCORDING TO THE DIAGRAM? YESNO | | ARE THE CABLES PROPERLY CLENCHED IN THE MOTOR TERMINAL BOX? yesno !

You might also like