0% found this document useful (0 votes)
29 views13 pages

Local Road Lighting Calculation

This document provides details on the local road lighting calculation for a street, including planning data and luminaire arrangements. Six pole-mounted luminaires and four bollard luminaires will be used. Design criteria and calculated values are given for average luminance, uniformity, illuminance, and other lighting metrics.

Uploaded by

Avinash Pradeep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views13 pages

Local Road Lighting Calculation

This document provides details on the local road lighting calculation for a street, including planning data and luminaire arrangements. Six pole-mounted luminaires and four bollard luminaires will be used. Design criteria and calculated values are given for average luminance, uniformity, illuminance, and other lighting metrics.

Uploaded by

Avinash Pradeep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Local road lighting calculation

8m high singlel arm pole on the side with 30m distance and 1m bollard for the sidewalk on both side of the road

Design Criteria:M5
Avg. Luminance (Lav) cd/m2 ≥0.5, Uniformity (U0) ≥ 0.35
Longitudinal Uniformity (Ul) ≥ 0.4, Threshold Index (Ti) ≤ 15
Walkway:P4
Avg. Illuminance (Eav) lux ≥5, (Emin) ≥ 1
Cycle track:P4
Avg. Illuminance (Eav) lux ≥5, (Emin) ≥ 1

Calculated Values:
Avg. Luminance (Lav) cd/m2 =0.65, Uniformity (U0) = 0.62
Longitudinal Uniformity (Ul) = 0.51, Threshold Index (Ti) = 7
Walkway:
Avg. Illuminance (Eav) lux = 10.05, (Emin) = 1.07
Cycle track:
Avg. Illuminance (Eav) lux = 7.24, (Emin) = 4.38

Date: 07.03.2024
Operator:
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Table of contents

Local road lighting calculation


Project Cover 1
Table of contents 2
Luminaire parts list 3
ewo ewo_FA170 COR-TEN_AP06-8led
Luminaire Data Sheet 4
COOPER LIGHTING SOLUTIONS - STREETWORKS (FORMERLY EATON) NVN-SA1B-7...
Luminaire Data Sheet 5
Street 1
Planning data 6
Photometric Results 8
3D Rendering 11
Valuation Fields
Valuation Field Roadway 1
Observer
Observer 4
Isolines (L) 12
Observer 5
Isolines (L) 13

Page 2
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Local road lighting calculation / Luminaire parts list

6 Pieces COOPER LIGHTING SOLUTIONS - See our luminaire catalog


STREETWORKS (FORMERLY EATON) NVN- for an image of the
SA1B-740-U-AFL NAVION ROADWAY AND AREA luminaire.
LUMINAIRE (1) 70 CRI, 4000K, 800mA
LIGHTSQUARE WITH 16 LEDS AND
AUTOMOTIVE FRONTLINE OPTICS
Article No.: NVN-SA1B-740-U-AFL
Luminous flux (Luminaire): 6009 lm
Luminous flux (Lamps): 6009 lm
Luminaire Wattage: 44.0 W
Luminaire classification according to CIE: 100
CIE flux code: 35 79 97 100 100
Fitting: 16 x User defined (Correction Factor
1.000).

4 Pieces ewo ewo_FA170 COR-TEN_AP06-8led See our luminaire catalog


Article No.: for an image of the
Luminous flux (Luminaire): 585 lm luminaire.
Luminous flux (Lamps): 585 lm
Luminaire Wattage: 4.8 W
Luminaire classification according to CIE: 100
CIE flux code: 20 50 90 100 100
Fitting: 1 x 70CRI-4000K-200mA (Correction Factor
1.000).

Page 3
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

ewo ewo_FA170 COR-TEN_AP06-8led / Luminaire Data Sheet

Luminous emittance 1:

See our luminaire catalog for an image of the luminaire.

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 20 50 90 100 100 be displayed for this luminaire.

Page 4
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

COOPER LIGHTING SOLUTIONS - STREETWORKS (FORMERLY EATON) NVN-SA1B-740-


U-AFL NAVION ROADWAY AND AREA LUMINAIRE (1) 70 CRI, 4000K, 800mA
LIGHTSQUARE WITH 16 LEDS AND AUTOMOTIVE FRONTLINE OPTICS / Luminaire
Data Sheet

Luminous emittance 1:

See our luminaire catalog for an image of the luminaire.

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 35 79 97 100 100 be displayed for this luminaire.

Page 5
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Planning data

Street Profile

Sidewalk 1 (Width: 4.450 m)


Bicycle Lane 1 (Width: 1.700 m)
Grass Strip 1 (Width: 0.500 m)
Roadway 1 (Width: 6.700 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Grass Strip 2 (Width: 0.500 m)
Bicycle Lane 2 (Width: 1.700 m)
Sidewalk 2 (Width: 4.450 m)

Light loss factor: 0.80


Luminaire Arrangements

Luminaire: COOPER LIGHTING SOLUTIONS - STREETWORKS (FORMERLY EATON) NVN-


SA1B-740-U-AFL NAVION ROADWAY AND AREA LUMINAIRE (1) 70 CRI, 4000K,
800mA LIGHTSQUARE WITH 16 LEDS AND AUTOMOTIVE FRONTLINE OPTICS
Luminous flux (Luminaire): 6009 lm Maximum luminous intensities
Luminous flux (Lamps): 6009 lm at 70°: 352 cd/klm
Luminaire Wattage: 44.0 W at 80°: 35 cd/klm
Arrangement: Single row, top at 90°: 0.00 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the
Mounting Height (1): 8.000 m luminaire installed for use.
Height: 8.000 m No luminous intensities above 90°.
Overhang (2): -1.500 m Arrangement complies with luminous intensity class G4.
Boom Angle (3): 0.0 ° Arrangement complies with glare index class D.3.
Boom Length (4): 0.500 m

Page 6
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Planning data

Luminaire Arrangements

Luminaire: ewo ewo_FA170 COR-TEN_AP06-8led


Luminous flux (Luminaire): 585 lm Maximum luminous intensities
Luminous flux (Lamps): 585 lm at 70°: 589 cd/klm
Luminaire Wattage: 4.8 W at 80°: 463 cd/klm
Arrangement: Double row, opposing at 90°: 0.00 cd/klm
Pole Distance: 14.000 m Any direction forming the specified angle from the downward vertical, with the
Mounting Height (1): 1.000 m luminaire installed for use.
Height: 1.000 m No luminous intensities above 90°.
Overhang (2): -5.900 m Arrangement complies with glare index class D.4.
Boom Angle (3): 0.0 °
Boom Length (4): 0.000 m

Page 7
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Photometric Results

Light loss factor: 0.80 Scale 1:258


Calculation Field List

1 Valuation Field Roadway 1


Length: 30.000 m, Width: 6.700 m
Grid: 10 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME5 (All lighting performance requirements are met.)

Lav [cd/m²] U0 Ul TI [%] SR


Calculated values: 0.65 0.62 0.51 7 0.56
Required values according to class: ≥ 0.50 ≥ 0.35 ≥ 0.40 ≤ 15 ≥ 0.50
Fulfilled/Not fulfilled:

Page 8
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Photometric Results

Calculation Field List

2 Valuation Field Bicycle Lane 1


Length: 30.000 m, Width: 1.700 m
Grid: 10 x 3 Points
Accompanying Street Elements: Bicycle Lane 1.
Selected Lighting Class: S4 (Not all lighting performance requirements are met.)

Eav [lx] Emin [lx]


Calculated values: 8.80 2.42
Required values according to class: ≥ 5.00 ≥ 1.00
Fulfilled/Not fulfilled: 1

1 Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5
times the minimum value indicated for the class.

3 Valuation Field Sidewalk 1


Length: 30.000 m, Width: 4.450 m
Grid: 10 x 3 Points
Accompanying Street Elements: Sidewalk 1.
Selected Lighting Class: S4 (Not all lighting performance requirements are met.)

Eav [lx] Emin [lx]


Calculated values: 10.61 1.70
Required values according to class: ≥ 5.00 ≥ 1.00
Fulfilled/Not fulfilled: 1

1 Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5
times the minimum value indicated for the class.

4 Valuation Field Sidewalk 2


Length: 30.000 m, Width: 4.450 m
Grid: 10 x 3 Points
Accompanying Street Elements: Sidewalk 2.
Selected Lighting Class: S4 (Not all lighting performance requirements are met.)

Eav [lx] Emin [lx]


Calculated values: 10.05 1.07
Required values according to class: ≥ 5.00 ≥ 1.00
Fulfilled/Not fulfilled: 1

1 Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5
times the minimum value indicated for the class.

Page 9
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Photometric Results

Calculation Field List

5 Valuation Field Bicycle Lane 2


Length: 30.000 m, Width: 1.700 m
Grid: 10 x 3 Points
Accompanying Street Elements: Bicycle Lane 2.
Selected Lighting Class: S4 (All lighting performance requirements are met.)

Eav [lx] Emin [lx]


Calculated values: 7.24 4.38
Required values according to class: ≥ 5.00 ≥ 1.00
Fulfilled/Not fulfilled:

Page 10
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / 3D Rendering

Page 11
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 4 / Isolines (L)

Values in Candela/m², Scale 1 : 258

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 1.675 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.70 0.62 0.70 4

Required values according to class ME5: ≥ 0.50 ≥ 0.35 ≥ 0.40 ≤ 15

Fulfilled/Not fulfilled:

Page 12
Local road lighting calculation
07.03.2024

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 5 / Isolines (L)

Values in Candela/m², Scale 1 : 258

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 5.025 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.65 0.65 0.51 7

Required values according to class ME5: ≥ 0.50 ≥ 0.35 ≥ 0.40 ≤ 15

Fulfilled/Not fulfilled:

Page 13