TDS H1Z2Z2-K

This cable is designed for use in photovoltaic solar systems to connect solar modules and inverters. It has a rated voltage of 1/1 kV AC and 1.5/1.5 kV DC, maximum operating temperature of 120°C, and is water resistant. The cable meets standards EN 50618 and IEC 60364-7-712 for photovoltaic systems and has cross-linked halogen-free insulation and sheathing.

Uploaded by

Dragana Skipina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views2 pages

TDS H1Z2Z2-K

This cable is designed for use in photovoltaic solar systems to connect solar modules and inverters. It has a rated voltage of 1/1 kV AC and 1.5/1.5 kV DC, maximum operating temperature of 120°C, and is water resistant. The cable meets standards EN 50618 and IEC 60364-7-712 for photovoltaic systems and has cross-linked halogen-free insulation and sheathing.

Uploaded by

Dragana Skipina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

H1Z2Z2-K

Photovoltaic Solar Cable

APPLICATION TECHNICAL
For free and stationary or for freely suspended outdoor CHARACTERISTICS
and indoor cabling between the solar modules, or between Test voltage: 6,5 kV
the module strings and the DC/AC inverter, for example in Rated voltage: 1/1 kV AC, 1,5/1,5 kV DC
line with HD 60364-7-712 on PV systems, and EN 50618 on Max. voltage: 1,8 kV
H1Z2Z2-K cable type, etc....; Short circuit and earth fault Min. temp. for cable laying: -25°C
protected per EN 50618, Annex A, and per HD 60364-5-52 Working temperature: -40°C to 90°C
Photovoltaic systems with DC system voltage up to 1800 V to Working temp. of max. 20000h: 120°C
ground. As per EN 50618, Annex A, inside electrical installation
Max. short-circuit temperature: 250°C
pipe/ duct/ channel, plaster, and appliance, as well as inside or
Min. bending radius: 4xD
connected to double insulated/ protected appliance or system
of protection class II. AD8: Permanent water contact and Water Resistant: AD8
submersion down to 1 metre in water depth.

CONSTRUCTION STANDARD
Conductors: Tinned copper conductor, class 5 EN 50618
Insulation: Halogen-free cross-linked compound
Sheath: Halogen-free cross-linked, flame retar-
dant compound

CERTIFICATION

CORE IDENTIFICATION
Outer Sheath Colour:
Black OR Red
Other colours available on request

page 1/2
NOMINAL MAX. RESIS- MAX. NOM. THICK- NOM. SINGLE SINGLE TWO CABLES OUTER CABLE
CROSS- TANCE RESISTANCE NESS OF THICKNESS CABLE IN CABLE ON ADJACENT DIAM. WEIGHT
SECTION AT 20°c AT 90°C INSULATION OF SHEATH AIR SURFACE ON SURFACE (APPROX.) (APPROX.)
mm² Ω/km Ω/km mm mm A A A mm kg/km
1x1,5 13,7 17,468 0,7 0,8 30 29 24 4,6 36
1x2,5 8,21 10,468 0,7 0,8 41 39 33 5,0 46
1x4 5,09 6,490 0,7 0,8 55 52 44 5,6 62
1x6 3,39 4,322 0,7 0,8 70 67 57 6,1 82
1x10 1,95 2,486 0,7 0,8 98 93 79 7,1 125
1x16 1,24 1,581 0,7 0,9 132 125 107 8,5 190
1x25 0,795 1,013 0,9 1,0 176 167 142 10,4 285
1x35 0,565 0,720 0,9 1,1 218 207 176 11,5 385
1x50 0,393 0,501 1,0 1,2 276 262 221 13,7 540
1x70 0,277 0,353 1,1 1,2 347 330 278 15,8 740
1x95 0,210 0,267 1,1 1,3 416 395 333 17,3 965
1x120 0,164 0,209 1,2 1,3 488 464 390 19,1 1210
1x150 0,132 0,168 1,4 1,4 566 538 453 21,4 1495
1x185 0,108 0,137 1,6 1,6 644 612 515 24,9 1885
1x240 0,082 0,104 1,7 1,7 775 736 620 27,3 2395

page 2/2