Page 2
ECI Multi Functional Weighing Controller Operating Manual
Page 3
ECI Multi Functional Weighing Controller Operating Manual
1 Considerations
• Do not power-up the device before making sure that the device connections are made according to this
manual.
• Do not open the case or disconnect-insert the connections before disconnecting the device from the power
source.
• Note that the load cell and communication cables are not very close to the energy lines.
• Note that the cables are not crushed.
• Operate the device within the stated temperature range.
• The device has been developed for indoor use. Do not expose sunlight, rain and other external factors.
Page 4
ECI Multi Functional Weighing Controller Operating Manual
Table of Contents
1 Considerations ........................................................................................................................................................... 4
2 Introduction .............................................................................................................................................................. 15
3 Physical Dimensions ................................................................................................................................................ 17
4 Specifications........................................................................................................................................................... 19
4.1 Technical Specifications .................................................................................................................................... 19
4.2 Use Properties................................................................................................................................................... 20
5 Installation and Connections .................................................................................................................................... 22
5.1 Standard Modules ............................................................................................................................................. 24
5.1.1 Slot1: Terminal (Supply and Communication Module) ................................................................................. 25
5.1.2 Slot2: Weighing (Load Cell) Module ........................................................................................................... 28
6 Screenshots ............................................................................................................................................................. 32
6.1 Weighing Main Screen ...................................................................................................................................... 32
6.1.1 Screen Layout ............................................................................................................................................. 33
Page 5
ECI Multi Functional Weighing Controller Operating Manual
Page 6
ECI Multi Functional Weighing Controller Operating Manual
Page 7
ECI Multi Functional Weighing Controller Operating Manual
Page 8
ECI Multi Functional Weighing Controller Operating Manual
Page 9
ECI Multi Functional Weighing Controller Operating Manual
Page 10
ECI Multi Functional Weighing Controller Operating Manual
Page 11
ECI Multi Functional Weighing Controller Operating Manual
Page 12
ECI Multi Functional Weighing Controller Operating Manual
Page 13
ECI Multi Functional Weighing Controller Operating Manual
Page 14
ECI Multi Functional Weighing Controller Operating Manual
2 Introduction
ECI is a smart signal converter and control device which is designed for weigh measuring systems. It is a
fast, sensitive device with a high accuracy class. It is designed suitably for using at industrial applications and standard
weigh measuring areas. It is used as weigh, force and pressure measuring areas. Many optional modules can be
added/modified easily thanks to the modular smart “plug and play” expansion structure.
This operating manual contains exemplary wording related to the installation, operation and field operation
of the ECI.
All written and visual materials contained in this operating manual are the property of ESİT Elektronik
Sistemleri İmalat ve Tic. Ltd. Şti.
Page 15
ECI Multi Functional Weighing Controller Operating Manual
Page 16
ECI Multi Functional Weighing Controller Operating Manual
3 Physical Dimensions
Standard Model
Weight 360 g
Page 17
ECI Multi Functional Weighing Controller Operating Manual
Page 18
ECI Multi Functional Weighing Controller Operating Manual
4 Specifications
4.1 Technical Specifications
Model ECI, E Series
Load Cell Input +/- 2.50–160mV/V
A/D Speed (/second) 1600
Screen Resolution 6 digit (1/1.000.000)
Supply 12-24V DC
Display LCD (101x33 pixel graphic, 4.5 inch)
Communication Terminal (Standard) RS-232 (9600-115200bps)
Communication Remote Display (Standard) For Remote Display (Opto-Coupler)
Communication Option Module (Optional) RS-232-RS-485 / RS-422 (E-MDL-COM insulated)
Load Cell Feeding 10 VDC (280mA, maximum 10 load cells)
Operating Temperature -10C / +50C
Protection Class IP65 (Front Panel)
Page 19
ECI Multi Functional Weighing Controller Operating Manual
Page 21
ECI Multi Functional Weighing Controller Operating Manual
Slot Numbers
Page 22
ECI Multi Functional Weighing Controller Operating Manual
• Slot1: Used for the Terminal (Supply & Communication) Module. Following module(s) can be used;
E-ECI-PWR (Standard) module can be inserted.
• Slot2: Used for Weighing (Load Cell) Module. Following module(s) can be used;
E-ECI-LC (Standard) module can be inserted.
• Slot3: Used for optional Communication Module. Following module(s) can be used;
E-MDL-COM (Optional), RS232 + RS485/RS422 Module
E-MDL-PRF (Optional), Profibus Module
E-MDL-EIP (Optional), Ethernet IP Module
• Slot4: Used for Optional Input/Output modules. Following module(s) can be used;
E-MDL-RLY, 4in/4out Module (Optional)
E-MDL-DAC, 0-10V / 4-20mA Analogue +2in/1out Module (Optional)
• Slot5: Used for Optional Input/Output modules. Following module(s) can be used;
E-MDL-RLY, 4in/4out Module (Optional)
E-MDL-DAC, 0-10V / 4-20mA Analogue +2in/1out Module (Optional)
• Slot6: Used for Expansion modules. Following module(s) can be used;
E-MDL-EXP, 8in/16out expansion module (Optional)
E-MDL-BCD, 20out/2In Optical Insulated BCD or Binary Output Module (Optional)
Page 23
ECI Multi Functional Weighing Controller Operating Manual
Terminal Module
Weighing
Module
Page 24
ECI Multi Functional Weighing Controller Operating Manual
RS232
C ti
Supply Connection
Page 25
ECI Multi Functional Weighing Controller Operating Manual
Note: When the “R.Display” output is used with Esit brand Remote displays, red and White cables of the Display must
be short circuited
Page 26
ECI Multi Functional Weighing Controller Operating Manual
Page 27
ECI Multi Functional Weighing Controller Operating Manual
Page 28
ECI Multi Functional Weighing Controller Operating Manual
Sense +
Esit Colours
Sense - Sense + Blue
Sense - Orange
Out + Out + White
Out - Red
Out - Supply + Green
Supply - Black
Supply +
Supply -
Grounding
Page 29
ECI Multi Functional Weighing Controller Operating Manual
Esit Colours
Sense - Green
Sense - Black
Out + Out + White
Out - Red
Out - Supply + Green
Supply - Black
Supply +
Sense-terminal is short
Supply -
circuit with Supply – terminal
and Sense+terminal is short
Grounding
circuit with Supply + terminal
Page 30
ECI Multi Functional Weighing Controller Operating Manual
Page 31
ECI Multi Functional Weighing Controller Operating Manual
6 Screenshots
6.1 Weighing Main Screen
Main screen shot will be as shown at side
Page 32
ECI Multi Functional Weighing Controller Operating Manual
6.1.2 Symbols
Indicates current weighing range. It is displayed when the measuring type is
Weighing
selected as “Multi Partition” or “Multi Range”. E1: Lower Zone, E2: Upper Zone
Range
and E3 represents the final zone.
Shows that the change in the weight value is within the stagnancy limits for a
Stagnancy certain period
(less than a one scale interval).
Mobility Shows that the change in the weight value is out of the stagnancy limits.
Zero
Indicates that deviation from zero is less than 1/4e (resolution).
Indicator
Net Shows that the tare has been removed and the displayed value is the net value.
Page 33
ECI Multi Functional Weighing Controller Operating Manual
Page 34
ECI Multi Functional Weighing Controller Operating Manual
6.1.3 Keys
Reset Key Used for resetting the display.
Tare Key Used for taking the weight on the load cell as tare.
Tare Clean Key Used for cancelling the tare value and showing the gross value.
Menu Key Used for bringing the display menu where the device settings are made.
Page 35
ECI Multi Functional Weighing Controller Operating Manual
Page 36
ECI Multi Functional Weighing Controller Operating Manual
6.2.2 Symbols
Page 37
ECI Multi Functional Weighing Controller Operating Manual
6.2.3 Keys
Left Arrow Key Used for shifting to an upper menu on the menu screen.
Up Arrow Key Used for browsing among the options on the menu screen.
Down Arrow Key Used for browsing among the options on the menu screen.
Right Arrow Key Used for shifting to an lower menu on the menu screen.
Enter Key Used for entering to the menu next to the menu number.
Page 38
ECI Multi Functional Weighing Controller Operating Manual
Note: The values entred in the screen must the multiplies of the
“Resolution” parameter. For example if the ”Resolution” is selected as 5 and the value entered in this screen is 101, an
information message appears and the number is automatically rounded to 100 and returned to the parameter
changing screen.
Page 39
ECI Multi Functional Weighing Controller Operating Manual
6.3.2 Symbols
Menu No Respective menu number.
Title Name of the current menu
Option Value to be adjusted
6.3.3 Keys
Used for returning to the menu screen from the parameter settings
Exit Key.
screen
Left Arrow Key Used for shifting the cursor to the left.
Used for decreasing the digit on which the cursor is located in the
Minus Key areas where numerical value is entered in the parameter setting
screen.
Used for increasing the digit on which the cursor is located in the areas
Plus Key
where numerical value is entered in the parameter setting screen.
Right Arrow
Used for shifting the cursor to the right.
Key
Confirm Key Used for confirming the selected screen.
Page 40
ECI Multi Functional Weighing Controller Operating Manual
Page 41
ECI Multi Functional Weighing Controller Operating Manual
Page 42
ECI Multi Functional Weighing Controller Operating Manual
6.4.2 Symbols
Menu No Respective menu number.
Menu Title Name of the respective parameter.
Option No Number of the parameter option.
Option Explanation of the respective parameter option.
Shows if there is any option above or below the
Arrow
selection list
6.4.3 Keys
Used for returning to the menu screen from the parameter settings
Exit Key.
screen
Up Arrow Key Used for browsing among the options in the selection list.
Down Arrow Key Used for browsing among the options in the selection list.
Page 43
ECI Multi Functional Weighing Controller Operating Manual
Page 44
ECI Multi Functional Weighing Controller Operating Manual
6.5.2 Symbols
Menu No Respective menu number.
Menu Title Name of the current menu.
Sub-Menu Title Name of the current sub-menu.
Sub-Menu No Sub-Menu number.
Number of Sub-
Number of Sub-Menus of the respective menu
Menu
Option No Option number
Option Respective option
Shows if there is any option above or below
Arrow
the selection list
Page 45
ECI Multi Functional Weighing Controller Operating Manual
6.5.3 Keys
Return Key Used for returning to the previous menu in the ordered menu.
Up Arrow Key Used for browsing among the options in the selection list.
Down Arrow Key Used for browsing among the options in the selection list.
Forward Key Used for forwarding to the next menu in the ordered menu.
Used for returning to the menu screen from the ordered menu
Exit Key.
screen
Page 46
ECI Multi Functional Weighing Controller Operating Manual
Page 47
ECI Multi Functional Weighing Controller Operating Manual
6.6.2 Symbols
Confirmation Screen
Respective menu title.
Title
Confirmation Screen
Respective menu logo.
Logo
Parameters Changed Name of the parameter changed
6.6.3 Keys
Cancel Key Used for returning to the previous menu without saving the parameters changed.
Confirm
Used for saving the parameters changed.
Key
Page 48
ECI Multi Functional Weighing Controller Operating Manual
Page 49
ECI Multi Functional Weighing Controller Operating Manual
6.7.2 Symbols
Page 50
ECI Multi Functional Weighing Controller Operating Manual
Page 51
ECI Multi Functional Weighing Controller Operating Manual
Page 52
ECI Multi Functional Weighing Controller Operating Manual
Page 53
ECI Multi Functional Weighing Controller Operating Manual
Page 54
ECI Multi Functional Weighing Controller Operating Manual
Page 55
ECI Multi Functional Weighing Controller Operating Manual
Terminal
It is the main menu that contains the device settings and the settings related to Slot1.
Language Selection
The language selection for the device. The options
are;
1) Turkish
2) English
Page 56
ECI Multi Functional Weighing Controller Operating Manual
Date
Date settings are made. The date data can be changed
in dd.mm.yyyy format.
Time
Time settings are made. The time data can be
changed in hh.mm format.
Page 57
ECI Multi Functional Weighing Controller Operating Manual
Communication
Serial Out
Contains the terminal serial out settings. This menu is an ordered type menu. Sub-menus are Mode
and Period. It functions differently in Indication, Batching and Filling programs. Explanation is made
below for each program
Indication Program
Mode
It is the communication type selection. The
options are;
For example;
The screen value of "2148.0kg" is sent as follows.
Character ‘‘ ‘‘ ‘‘ ‘‘ ‘ 2‘ ‘ 1‘ ‘ 4‘ ‘ 8‘ ‘.’ ‘ 0‘ CR
Ascii 32 32 32 32 50 49 52 56 46 48 13
Hex 20 20 20 20 32 31 34 38 2E 30 0D
Page 58
ECI Multi Functional Weighing Controller Operating Manual
Page 59
ECI Multi Functional Weighing Controller Operating Manual
2) Accuracy: Net weight information is sent continuously. (Baudrate is 9600bps)The format of the
data string sent is same as the Speed mode
3) Detail: The weight information is sent in detail.(Baudrate is 9600bps).The format of the data
string sent is as follows.
Net TAB Tare TAB Gross TAB Date TAB Time TAB Status CR
169.2 Chr 9 128.5 Chr 9 297.7 Chr 9 12/02/2013 Chr 9 09:52 Chr 9 S CR
Status
E:Error
Z:Absolute Zero
S:Stagnancy
- :This symbol appears when non of the abovementioned conditions occur.
Page 60
ECI Multi Functional Weighing Controller Operating Manual
4) Stability: Net weight information is sent 10 times when the stability is observed.(Baudrate is
9600 bps.) The format of the data string sent is same as the Speed mode.
Page 61
ECI Multi Functional Weighing Controller Operating Manual
For example;
Command: GI0
Response: 1001->LSB(Input1)
1 0 0 1
Input4 Input3 Input2 Input1
0: No Input:
1: Input exists
For example;
Command: GO0
Response: 3
The binary number system equivalent of the response received: 0011
0 0 1 1
Exit4 Exit3 Exit2 Exit1
1: Exit
0: No Exit
Page 62
ECI Multi Functional Weighing Controller Operating Manual
6) Printer: It is the printer connection option. This option is locked as it is not active under the
indication program.
Period
Selection for RS232 serial out sending frequency.
The options are;
1) 6/Min
2) 1/Sec
3) 10/Sec
4) 100/Sec
5) 400/Sec
6) 800/Sec
Not: Period menu is not shown when "Command" or "Stability" modes are selected.
When "Speed" Mode is selected, Period can be selected as 100-800/Sec
When "Accuracy" mode is selected, Period can be selected as 6/Min-10/Sec
When "Detail" mode is selected, Period can be selected as 6/Min-10/Sec
Page 63
ECI Multi Functional Weighing Controller Operating Manual
Batching Program
Mode
It is the communication type selection. The
options are;
For example;
The screen value of "2148.0kg" is sent as follows.
Character ‘‘ ‘‘ ‘‘ ‘‘ ‘ 2‘ ‘ 1‘ ‘ 4‘ ‘ 8‘ ‘.’ ‘ 0‘ CR
Ascii 32 32 32 32 50 49 52 56 46 48 13
Hex 20 20 20 20 32 31 34 38 2E 30 0D
Page 64
ECI Multi Functional Weighing Controller Operating Manual
2) Accuracy: Net weight information is sent continuously during the batching operation. (Baudrate
is 9600bps)The format of the data string sent is same as the Speed mode
3) Detail: The information is sent in detail after the batching operation is over. (Baudrate is
9600bps).The format of the data string sent is as follows.
Silo
Meter TAB TAB Silo Weight TAB Total TAB Date TAB Time CR
Name
2 Chr 9 Silo3 Chr 9 300 Chr 9 1200 Chr 9 16.04.2013 Chr 9 08:50:19 CR
Meter Total number of Batching Resets when the recipe is changed or the device is
restarted.
Silo No Number of the last silo from which good was taken
Silo Weight Quantity of the goods taken from the last silo
Total Last batching amount
Date Last batching date
Time Last batching time
Page 65
ECI Multi Functional Weighing Controller Operating Manual
4) Stability: The total batching weight is sent after the batching is over.(Baudrate is 9600 bps.) The
format of the data string sent is same as the Speed mode.
Auto Print
It is the printer operation mode selection. The
options are;
1) Manuel: Printing is only possible from the
"Report" screen.
2) After Filling: Printing operation is made
according to the settings in "Printer Settings
Menu" after the batching is completed. key
is also used for manual printing at the report screen.
Page 66
ECI Multi Functional Weighing Controller Operating Manual
Period
Selection for RS232 serial out sending frequency.
The options are;
7) 6/Min
8) 1/Sec
9) 10/Sec
10) 100/Sec
11) 400/Sec
12) 800/Sec
Not: Period menu is not shown when "Command" or "Stability" modes are selected.
When "Speed" Mode is selected, Period can be selected as 100-800/Sec
When "Accuracy" mode is selected, Period can be selected as 6/Min-10/Sec
When "Detail" mode is selected, Period can be selected as 6/Min-10/Sec
Page 67
ECI Multi Functional Weighing Controller Operating Manual
Filling Program
Mode
It is the communication type selection. The
options are;
For example;
The screen value of "2148.0kg" is sent as follows.
Character ‘‘ ‘‘ ‘‘ ‘‘ ‘ 2‘ ‘ 1‘ ‘ 4‘ ‘ 8‘ ‘.’ ‘ 0‘ CR
Ascii 32 32 32 32 50 49 52 56 46 48 13
Hex 20 20 20 20 32 31 34 38 2E 30 0D
Page 68
ECI Multi Functional Weighing Controller Operating Manual
3) Detail: The information is sent in detail after the filling operation is over. (Baudrate is
9600bps).The format of the data string sent is as follows.
Filling
Meter TAB TAB Tare TAB Gross TAB Date TAB Time CR
Quantity
Chr Chr Chr Chr Chr
3 1000 100 1100 16.04.2013 09:25:50 CR
9 9 9 9 9
Meter Total number of filling. Resets when the product is changed or the device is restarted.
Filling
Value of the Last Filling
Quantity
Tare The weight value on the weighing platform when the filling started
Gross Sum of the filling quantity and the Tare value
Date Date of the Last Filling
Time Time of the Last Filling
Page 69
ECI Multi Functional Weighing Controller Operating Manual
4) Stability: The final filling weight is sent after the filling is over.(Baudrate is 9600 bps.) The format
of the data string sent is same as the Speed mode.
5) Command: This mode will be shown as locked as it is not active in filling program.
Auto Print
It is the printer operation mode selection. The
options are;
1) Manuel: Printing is only possible from the
"Report" screen.
2) After Filling: Printing operation is made
according to the settings in "Printer Settings
Menu" after the filling is completed. Key is
also used for manual printing at the report screen.
Page 70
ECI Multi Functional Weighing Controller Operating Manual
Period
Selection for RS232 serial out sending frequency.
The options are;
1) 6/Min
2) 1/Sec
3) 10/Sec
4) 100/Sec
5) 400/Sec
6) 800/Sec
Not: Period menu is not shown when "Command" , "Stability" or "Detail modes are selected.
When "Speed" Mode is selected, Period can be selected as 100-800/Sec
When "Accuracy" mode is selected, Period can be selected as 6/Min-10/Sec
When "Detail" mode is selected, Period can be selected as 6/Min-10/Sec
Page 71
ECI Multi Functional Weighing Controller Operating Manual
Page 72
ECI Multi Functional Weighing Controller Operating Manual
Page 73
ECI Multi Functional Weighing Controller Operating Manual
USB Recording
It is the menu where the recording settings are made. This menu is an ordered type menu. Sub-menus
are Mode and Period. It is active under filling and indication programs.
Mode
It is the recording type selection. The options are;
1) Inactive: No recording is made.
2) Weight: Net weight value is recorded.
3) Detail: Weight data is recorded in detail.
Page 74
ECI Multi Functional Weighing Controller Operating Manual
Net CR
169.2 CR
Net TAB Tare TAB Gross TAB Date TAB Time TAB Status CR
169.2 Chr 9 128.5 Chr 9 297.7 Chr 9 12/02/2013 Chr 9 09:52 Chr 9 S CR
Status
E:Error
Z:Absolute Zero
S:Stagnancy
- :This symbol appears when non of the abovementioned conditions occur.
The name of the saved file is as "YearMonthDayeMode" format. For example; 20130412D
Page 75
ECI Multi Functional Weighing Controller Operating Manual
Net CR
100 CR
Meter TAB Date TAB Time TAB Total TAB Silo1 TAB Silo2 CR
1 Chr 9 12/02/2013 Chr 9 09:52 Chr 9 100 Chr 9 75 Chr 9 25 CR
Meter It is the batching number. Resets when the recipe is changed or the device is
turned on.
Date Date data in Day.Month.Year format.
Time Time data in Hour.Minute.Second format.
Total The amount of goods batched
Silo1 Quantity of the goods taken from Silo1
Silo2 Quantity of the goods taken from Silo2
Page 76
ECI Multi Functional Weighing Controller Operating Manual
Page 77
ECI Multi Functional Weighing Controller Operating Manual
Net CR
1000 CR
Meter TAB Total TAB Tare TAB Gross TAB Date TAB Time CR
1 Chr 9 1000 Chr 9 100 Chr 9 1100 Chr 9 12/02/2013 Chr 9 09:52:23 CR
Meter It is the batching number. Resets when the recipe is changed or the device is
turned on.
Total The amount of goods batched
Tare It is the tare value received at the beginning of the filling when the Automatic
Tare "On" is selected
Gross Sum of the total and tare value
Date Date data in Day.Month.Year format.
Time Time data in Hour.Minute.Second format.
Page 78
ECI Multi Functional Weighing Controller Operating Manual
Page 79
ECI Multi Functional Weighing Controller Operating Manual
Period
It is the selection for USB Recording frequency. The
options are;
1) 10/Sec
2) 1/Sec
3) 1/Min
4) 4/Hour
Not: The Period menu is not displayed when "Inactivate" mode is selected
Period menu is not displayed in Batching and Filling programs.
When "Detail" mode is selected, Period can not be selected as 10/Sec
Page 80
ECI Multi Functional Weighing Controller Operating Manual
Keys
It is the menu where the key settings are made. This menu is an ordered type menu. Sub-menus are
"Tone" and "Sensitivity".
Tone
It is the key tone selection. The options are;
1) On
2) Off
Sensitivity
It is the selection for the perception setting of the
keys The options are;
1) Sensitive: It is the option where the perception is
the highest. Suitable for using with gloves.
2) Standard: It is the state of normal operation.
3) Stable: It is the option where the perception is the
lowest.
Page 81
ECI Multi Functional Weighing Controller Operating Manual
Service
LCDPixelTest
It is the screen test menu in LCD. Pixel and rear
light control is made.
CPU Temperature
Inside temperature of the device is displayed for 3
seconds.
Memory Test
It is used for understanding whether the memory is
functional or not.
Page 82
ECI Multi Functional Weighing Controller Operating Manual
CommunicationTest
Terminal
It is used for understanding whether the
communication port is functional or not. The
data received from the serial port is displayed
at the receiving section. "ESIT" wording is sent
to the serial port at the same time.
Remote Display
It is used for understanding whether the
communication port is functional or not. "ESIT"
wording is sent to the remote display.
Serial No
Used for displaying the device serial number.
Page 83
ECI Multi Functional Weighing Controller Operating Manual
Version No
Used for displaying the device version number.
FactorySettings
Used for returning the device parameters to the
Factory settings.
Note: The device can also be returned to the factory settings by pressing to the calibration key for 10 seconds while
the device is at the main screen. The warning screen appearing later on will display that the factory settings will be
returned and sound warning is given. The factory settings will be returned when it is pressed for an additional period of
25 seconds.
Restart
Used for restarting the device.
Page 84
ECI Multi Functional Weighing Controller Operating Manual
Weighing
It is the menu that contains weighing device (Slot2-Load Cell Module) parameters.
Note: If the symbol presents in any of the sub-menus of the Weighing menu, then the menu cannot be accessible.
In such case, it is necessary to press the calibration case to activate in order to access the menu.
Calibration Key
Page 85
ECI Multi Functional Weighing Controller Operating Manual
Security Type
Contains the weighing device security settings. The
options are;
1) Commercial Use:Weighing parameters and
calibration cannot be changed. (Locked)
2) CalibrationLock: Weighing parameters can be
changed but the calibration cannot be changed.
(Locked)
3) Unlocked: Weighing parameters and calibration can be changed.
Note: If the security type is selected as "Commercial Use" or "Calibration Lock", primarily the calibration key should be
pressed and the lock should be removed for making any change.
Page 86
ECI Multi Functional Weighing Controller Operating Manual
Settings
This menu is an ordered type menu where the weighing parameters are set forth. The sub-menus are
"Unit", "Capacity", "Resolution" and "Measuring Type".
Unit
Determines the unit of the weighing device . The
options are;
1) (g)Gram
2) (kg)Kilogram
3) (t)Ton
4) (N)Newton
5) (lb)Libre
6) (lt)Litre
7) (mV/V) Input
8) (m3)Cubic meter
9) None
Capacity
It is the capacity value of the device. The capacity of
the load cell must not be exceeded.
Page 87
ECI Multi Functional Weighing Controller Operating Manual
Resolution
It is the scale interval (e) selection.
e: It is the smallest screen change quantity.
Scale Interval
Scale Interval is automatically calculated as the
multiplies of 1, 2 and 5 depending on the capacity
parameter and presented as a selection. The options
are;
1) Capacity / 6000: The value calculated as 1/6000
as standard.
2) Capacity / 3000: The value calculated as 1/3000 as standard.
3) Capacity / 1500: The value calculated as 1/1500 as standard.
4) Custom: This option is selected if it is desired to select a resolution other than these first three
options.
Page 88
ECI Multi Functional Weighing Controller Operating Manual
When the custom resolution is selected Multiple and Scale Interval menus appear and the product of
the values selected in these menus are determined as the walking step.
Multiples
The options are;
1) 1000
2) 100
3) 10
4) 1
5) 0.1
6) 0.01
7) 0.001
Scale Interval
The options are;
1) 1
2) 2
3) 5
Page 89
ECI Multi Functional Weighing Controller Operating Manual
Measuring Type
Determines the operation of the weighing device. In weighing devices;
“e”: is referred as the scale interval It is the difference between two subsequent indications.
There may be a signle "e" division as well as more than one partitions. The options related to this
parameter are;
1) Single Partition
2) Multi Interval
3) Multi Partition
Page 90
ECI Multi Functional Weighing Controller Operating Manual
Single Partition: The weighing device with a single scale interval and capacity.
Multi Interval: In this operation there are 3 different scale intervals and
capacities. There is a different scale interval in each capacity range;
Weight < LowerZoneLimit + 9e1 e1 (the first zone scale interval)
LowerZoneLimit + 9e1 < Weight < UpperZoneLimit + 9e2 e2 = 2*e1
(the second zone scale interval)
UpperZoneLimit + 9e1 < Weight < Capacity + 9e3 e3 = 2*e2 (the
third zone scale interval)
"e1" scale interval is determined with Resolution parameter. e2 and e3
are determined automatically. If the respective zone capacity +9e is
observed when the weight is increased, it is proceeded to the next
scale interval. When the weight is decreasing, it is decreased to the
previous scale interval when it is shifted from the upmost zone to the
lowest one or from the lower zone to the 1. zone. The scale interval can
be the multiples of 1,2 and 5. For example when e1=2, e2=2*e1=2*2=4 and calculated as 5 which is the next scale
interval.
Page 91
ECI Multi Functional Weighing Controller Operating Manual
Page 92
ECI Multi Functional Weighing Controller Operating Manual
UpperZoneLimit:
It is activated when the measuring type is selected
as "Multi Interval" or "Multi Partition". It is the
maximum value that relates to the 2. scale interval
(e2).
LowerZoneLimit:
It is activated when the measuring type is selected
as "Multi Interval" or "Multi Partition". It is the
maximum value that relates to the 1. scale interval
(e1).
Page 93
ECI Multi Functional Weighing Controller Operating Manual
Filter
It is the menu where the filter settings are made. This menu is an ordered type menu. The sub-menus are
"Mode", "AverageQuantity", "Speed", "Vibration" and "Stability Period".
Mode
It is the filter mode selection. The options are;
1) Gresolver: It is the advanced numerical filtering
option. The input signal is processed through
advanced mathematical functions and gives rapid and
stable results.
2) Moving Average: It is the standard numerical
filtering option. Moving average method is used.
3) No Filter: No filter is applied.
Vibration
It is the selection for the vibration intensity in the
environment. The options are;
1) Low
2) Medium
3) High
Note: When Moving Average is selected no "Vibration" is
displayed.
Page 94
ECI Multi Functional Weighing Controller Operating Manual
Average Quantity
The selection for the number data to be used for the
moving average filter. The options are;
1) 8
2) 16
3) 32
Note: When gResolver mode is selected, "AverageQuantity" is not
displayed
Speed
It is the ADC measuring speed. The options are;
1) 6.25 Hz
2) 12.5 Hz
3) 50 Hz
4) 100 Hz
5) 400 Hz
6) 800 Hz
Note: When gResolver mode is selected, "Speed" is not displayed It is detected automatically.
Page 95
ECI Multi Functional Weighing Controller Operating Manual
Stability Period
The options are;
1) Short (0.5 sec): Current measurement value is
monitored for 0,5 sec.
2) Medium (1.0 sec): Current measurement value is
monitored for 1 sec.
3) Long (2.0 sec): Current measurement value is
monitored for 2 sec.
Page 96
ECI Multi Functional Weighing Controller Operating Manual
Zero/Tare
It is the menu where the zeroing and taring are made. This menu is an ordered type menu. The
sub*menus are "Mode", "Zero Limit", "Starting Zero" and "Stagnancy".
Mode
The options are;
1) Manuel: Zeroing is only made by using
key.
2) Zero Monitoring: The shifts in the weight value
are zeroed as long as the gross value is zero.
3) Start-up: The option of zeroing at start-up. It
operates with the % ratio selected in "Start-up Zero"
menu. Zero monitoring is also active.
4) Auto-Zeroing: It is the full automatic zeroing option. Start-up is also active. In case of stagnancy (
), the screen is resetted in the % ratio as selected in "Zero Limit" menu once in every 3 seconds.
Page 97
ECI Multi Functional Weighing Controller Operating Manual
Zero Limit
1) %1 Capacity: Zeroing is made if the weight value
of less than 1 % of the Capacity.
2) %2 Capacity: Zeroing is made if the weight value
of less than 2 % of the Capacity.
3) %10 Capacity: Zeroing is made if the weight value
of less than 10 % of the Capacity.
Start-up Zero
Determines at which ratio of the "Capacity" value will the zeroing be made at first start-up of the device.
The options are;
1) %5 Capacity: Zeroing is made if the weight value
of less than 5 % of the Capacity.
2) %10 Capacity: Zeroing is made if the weight
value of less than 10 % of the Capacity.
3) %25 Capacity: Zeroing is made if the weight value
of less than 25 % of the Capacity.
Note: The start menu is not displayed when "Manuel" mode is selected.
Page 98
ECI Multi Functional Weighing Controller Operating Manual
Stagnancy
The options are;
1) Stab.Wait: Stagnancy( ) is necessary for
taring and zeroing. If there is no stagnancy warning
message is displayed on the screen.
2) Always: Taring and zeroing is made regardless of
stagnancy.
Page 99
ECI Multi Functional Weighing Controller Operating Manual
Calibration
It is explained in detail in Calibration section.
Service
Sys.Doctor
System doctor interprets the values obtained from the load cell and provides detailed information on
the ambient vibration, load status and drift.
Page 100
ECI Multi Functional Weighing Controller Operating Manual
A/D Count
ADC internal count value is displayed on the
screen. Expresses the numerical equivalent of the
signal connected to the Load Cell module. Count
Value varies depending on the "Load Cell Type"
selection. Maximum values are shown in the table
given below.
A/D mV/V
ADC mV/V value is displayed on the screen.
Expresses the mV/V value received from the
sensor connected to the Load Cell module. It is
used from controlling the load cell output.
Page 101
ECI Multi Functional Weighing Controller Operating Manual
Back-up
The Weighing settings and calibration information on ECI can be backed-up to the "Load Cell
Module" in Slot 2. Thus, the previous weighing settings can be recovered anytime by making Back-up
> Recovery operation. Furthermore the "Load Cell Module" which contains the back-up can be
inserted to another ECI and the weighing setting and calibration data can be transferred to another
device by making Back-up > Recovery operation.
Back-up
The Weighing settings and calibration
information saved on ECI are backed-up to the
"Load Cell Module".
Recover
The Weighing settings and calibration
information saved on the "Load Cell Module"
are transferred to ECI.
Page 102
ECI Multi Functional Weighing Controller Operating Manual
Note: If not Back-up operation is made to the "Load Cell Module" before, then no "Recovery" operation can be made
and relevant message will be displayed.
Page 103
ECI Multi Functional Weighing Controller Operating Manual
COM Module
This is the menu where the parameters of the COM module
are set forth.
Settings
This menu is an ordered type menu where the communication parameters are set forth. The sub-menus
are "Mode", "Baudrate", "Period" and "Modbus Mode" and "Modbus No".
Page 104
ECI Multi Functional Weighing Controller Operating Manual
Mode
It is the communication type selection.
Character ‘‘ ‘‘ ‘‘ ‘‘ ‘ 2‘ ‘ 1‘ ‘ 4‘ ‘ 8‘ ‘.’ ‘ 0‘ CR
Ascii 32 32 32 32 50 49 52 56 46 48 13
Hex 20 20 20 20 32 31 34 38 2E 30 0D
Page 105
ECI Multi Functional Weighing Controller Operating Manual
3) Detail: Weight data is sent in detail. (Baudrate is 9600bps)The format of the data string sent is same
as follows.
Net TAB Tare TAB Gross TAB Date TAB Time TAB Status CR
169.2 HT 128.5 HT 297.7 HT 12/02/2013 HT 09:52 HT S CR
Status
E:Error
Z:Absolute Zero
S:Stagnancy
- :This symbol appears when non of the abovementioned conditions occur.
4) Stability:Net weight information is sent 10 times per second when stability is observed. (Baudrate is
9600bps) The format of the data string sent is same as the Speed mode.
Page 106
ECI Multi Functional Weighing Controller Operating Manual
Command List:
'R': Resets the device (Reset).
'Z': Functions as reset key.
'T': Functions as taring key.
'W': Sends existing measurement results
'GIn': Sends digital inputs
'GOn': Sends digital outputs
'A': Sends ADC internal count value.
'V': Sends device version number.
Page 107
ECI Multi Functional Weighing Controller Operating Manual
Baudrate
It is the selection for RS232 serial output communication speed. The options are;
1) 1200
2) 2400
3) 4800
4) 9600
5) 19200
6) 38400
7) 57600
8) 115200
Page 108
ECI Multi Functional Weighing Controller Operating Manual
Period
Selection for optional module serial out transmission frequency. The options are;
1) Stable: Transmission is made when stability is observed (10Hz).
2) 6/Min: Option for transmission frequency per minute.
3) 1/Sec: Option for transmission frequency per
second.
4) 10/Sec: Option for transmission frequency per
second.
5) 100/Sec: Option for transmission frequency per
second.
6) 400/Sec: Option for transmission frequency per
second.
7) 800/Sec: Option for transmission frequency per second.
Note: Period can be selected as only "Stable" when "Command" or "Stability" modes are selected.
When "Speed" Mode is selected, Period can be selected as 100-800/Sec
When "Accuracy" or "Detail" mode is selected, Period can be selected as 6/Min-10/Sec
No Period can be selected when "Off" mode is selected.
Page 109
ECI Multi Functional Weighing Controller Operating Manual
Modbus Mode
It is the Modbus communication mode. The options
are;
1) RTU: Each byte data to be sent is meaningful and
the transmission is made by coding with CRC control
byte.
2) ASCII: Each byte data to be sent is sent as two
separate bytes and in coding that can be displayed as
Ascii. For example; for 26 (hex:1A) decimal data transmission, the characters "1" and "A" are set. Thus
the communication speed is slower than RTU.
Modbus No
The identity number to be used by the device during
Modbus communication.
Page 110
ECI Multi Functional Weighing Controller Operating Manual
Service
It is used for understanding whether the communication
port is functional or not. The data received from the
serial port is displayed at the receiving section. "ESIT"
wording is sent to the serial port at the same time.
Page 111
ECI Multi Functional Weighing Controller Operating Manual
Profibus Address
The address number to be used by the device for the
profibus communication.
Service
The screen where the profibus communication
settings are displayed.
Page 112
ECI Multi Functional Weighing Controller Operating Manual
IP Address
The address number to be used by the device for the Ethernet IP communication.
IP.xx.xx.xx
1. part of the IP address. Value between 1-255 can
be entered.
Page 113
ECI Multi Functional Weighing Controller Operating Manual
xx.IP.xx.xx
2. part of the IP address. Value between 1-255 can
be entered.
xx.xx.IP.xx
3. part of the IP address. Value between 1-255 can
be entered.
xx.xx.xx.IP
4. part of the IP address. Value between 1-255 can
be entered.
Page 114
ECI Multi Functional Weighing Controller Operating Manual
Service
The screen where the Ethernet IP communication
settings are displayed.
Page 115
ECI Multi Functional Weighing Controller Operating Manual
Outs
It is the menu where the relay settings are made.
Relay1
It is the menu where the Relay1 settings are made. Following expressions are valid when "Norm.On"
is selected as the "Contact type".
Page 116
ECI Multi Functional Weighing Controller Operating Manual
Mode
It is the relay operation mode selection. The
options are;
1) Inactive: The relay is not active.
2) Net Value: Operates according to the NET
value. Taring affects the operation of the relay.
3) Gross Value: Operates according to the
gross weight. Relay set values function independent from the Tare.
4) Ready Signal: Relay contacts are short circuit as long as the device is in operation.
5) Error Signal: In the occurrence of any of the following error situations relay contacts are short
circuit , but open circuit in other situations.
Error situations:
LoadCellError (error of the sensor connected to the load cell)
Maximum Load! (The situation where the measured values exceed the Maximum Capacity)
ADC Data Error! (Load Cell Module Error)
No Load Cell Module! (Load Cell Module could not be recognized error)
6) Stagnancy: If the change in the measurement result is less than a scale interval (if
symbol is displayed on the screen), the relay contacts are short circuit otherwise (if is
displayed on the screen) open circuit.
7) Tare Signal: While taring ( when symbol is displayed), relay contacts are short circuit,
when the tare is removed (when symbol is displayed ), the relay contacts are open circuit.
Page 117
ECI Multi Functional Weighing Controller Operating Manual
Minimum
It is active when "Net Value" or "Gross Value"
mode is selected. It is the lowest value of the
weight range where the relay contact will be
active.
Maximum
It is active when "Net Value" or "Gross Value"
mode is selected. It is the highest value of the
weight range where the relay contact will be
active.
Page 118
ECI Multi Functional Weighing Controller Operating Manual
Delay
Determines the period after which the relay
contact will change state after the desired
situation occur.
Contact Type
Determines the start-up positions of the relays
contacts. The options are;
1) Norm.On:Relay contact is open circuit at
start-up.
2) Norm.Off:Relay contact is short circuit at
start-up.
Page 119
ECI Multi Functional Weighing Controller Operating Manual
Contact Status
Mode : Net Value, Gross Value
Contact Type : Norm.On
On Screen Value
Minimum Maximum
Contact Status
Mode : Net Value, Gross Value
Contact Type : Norm.On
Off
Delay Delay
On Screen Value
Minimum Maximum
Page 120
ECI Multi Functional Weighing Controller Operating Manual
Contact Status
Mode : Ready Signal, Error Signal, Stagnancy, Tare Signal
Contact Type : Norm.On
Contact Status
Mode : Ready Signal, Error Signal, Stagnancy, Tare Signal
Contact Type : Norm.On
Off
Delay. Delay
Page 121
ECI Multi Functional Weighing Controller Operating Manual
Relay2
Relay3
Relay4
Relay2, Relay3 and Relay 4 menus are same as Rela1 menu.
Inputs
It is the section on the relay module where the digital input settings are made.
Input1
The parameter that contains options related to the
input. The options are;
1) Inactive: No task is appointed for the input
signal
2) Zeroing: The device performs zeroing operation
when input signal is detected.
3) Tare: The device performs taring operation when input signal is detected.
Input2
Input3
Input4
Input 2, Input 3 and Input 4 are same as the Input 1 menu.
Page 122
ECI Multi Functional Weighing Controller Operating Manual
Service
Inputs
The status of the inputs can be monitored and
controlled real time from this menu. The inputs that
are applied 12-24 V DC are displayed as 1 and
other are displayed as 0.
Outputs
In this menu when key is pressed, relays are
pulled in order and the relays pulled are displayed
as 1 and other are displayed as 0.
Page 123
ECI Multi Functional Weighing Controller Operating Manual
DAC Module
This is the menu where the parameters of the DAC module
are set forth.
Page 124
ECI Multi Functional Weighing Controller Operating Manual
Analogue Output
This menu contains the Analogue Output module settings.
Voltage Output : between- 0,500V / 10.500V range.
Current Output : between 0mA / 20.320mA range.
Page 125
ECI Multi Functional Weighing Controller Operating Manual
Mode
1) Gross: Analogue Output will function according
to the Gross value.
2) Net: Analogue Output will function according to
the Net value.
Weight Ref
Minimum:
The weight value that corresponds the start
value of the analogue output.
For example if it is desired that the Analogue
output tension varies between 1000g and
2000g, the value 1000g is entered here.
Maximum:
The weight value that corresponds the end
value of the analogue output.
For example if it is desired that the Analogue
output tension varies between 1000g and
2000g, the value 2000g is entered here.
Page 126
ECI Multi Functional Weighing Controller Operating Manual
Volt.Ref
Minimum:
It is the start value of the Analogue Output
For example if it is desired that the Analogue
output voltage varies between 0 V and 10 V,
the value 0 V is entered here.
If it is desired to use current (0-20mA) output instead of the voltage (0-10V) output, the current
values corresponding to the voltage output are as follows.
Voltage Output 0Volt 2Volt 5Volt 10Volt
Current Output 0mA 4mA 10mA 20mA
Maximum:
It is the end value of the Analogue Output.
For example if it is desired that the Analogue
output voltage varies between 0 V and 10 V,
the value 10 V is entered here.
Page 127
ECI Multi Functional Weighing Controller Operating Manual
Digital Output
The section of the DAC module which contains the settings related to the Digital Output.
Mode
It is the output operation mode selection. The
options are;
1) Inactive: The relay is not active.
2) Net Value: Output is given between the
minimum and maximum values of the net value,
otherwise no output is given.
3) Gross Value: Output is given between the
minimum and maximum values of the gross value, otherwise no output is given.
4) Ready Signal: Output is given as long as the device is in operation.
5) Error Signal: Output is given when any of the error situations stated below emerges, otherwise no
output is given. Error situations:
LoadCellError LoadCellModule reading error!
Maximum Load! LoadCell Module Hardware error!
6) Stagnancy If the change in the measurement result is less than a scale interval (if symbol
is displayed on the screen), output is given, otherwise (if symbol is displayed on the screen) no
output is given.
7) Tare Signal: While taring (when symbol is on the scree) output is given. When tare is
removed (when symbol is on the scree) no output is given.
Page 128
ECI Multi Functional Weighing Controller Operating Manual
Minimum
It is active when Net Value or Gross Value mode is
selected. It is the lowest value of the weight range
where the output is active.
Maximum
It is active when Net Value or Gross Value mode is
selected. It is the highest value of the weight range
where the output is active.
Page 129
ECI Multi Functional Weighing Controller Operating Manual
Delay
Determines the period after which the output will be
activated after the desired situation occur.
Output Type
Determines the status of the digital output signal at
start-up. The options are;
1) Norm. On: There is digital output signal at start-
up.
2) Norm. Off: There is no digital output signal at
start-up.
Page 130
ECI Multi Functional Weighing Controller Operating Manual
DigitalInput
Input1
1) Inactive: The input is not active.
2) Zeroing: The device performs zeroing
operation when input signal is detected.
3) Tare: The device performs taring operation
when input signal is detected.
Input2
Same as Input1.
Page 131
ECI Multi Functional Weighing Controller Operating Manual
Service
Inputs
Real time status of the inputs can be monitored
from this menu.The inputs that are applied 12-24 V
DC are displayed as 1 and other are displayed as
0.
Outputs
When key is pressed in this menu, the output
is periodically activated in order to control it. When
the output is active 1, otherwise 0 is displayed on
the screen.
Page 132
ECI Multi Functional Weighing Controller Operating Manual
Mode
1) BCD Output: BCD (Binary Coded Decimal) is the
binary coding of the numbers in Decimal number
system 41/2 digit (39999) output data is coded.
2) Binary 2’ All: BINARY'2 is the integrated output in
binary number system. 1 sign + 19 bit (±524.287)
output data is provided.
3) BinaryAbsolute: It is the absolute output coded in
Page 133
ECI Multi Functional Weighing Controller Operating Manual
binary number system. 1 sign + 19 bit ( 524.287) output data is provided. Binary functions in the same
way with the complement.
Page 134
ECI Multi Functional Weighing Controller Operating Manual
BCD Output:
12495 kg -1780 kg ERROR
SIGN 0 1 1
D18 0 0 0
D17 0 0 0
D16 1 0 0
D15 0 0 0
D14 0 0 0
D13 1 0 0
D12 0 1 0
D11 0 0 0
D10 1 1 0
D9 0 1 0
D8 0 1 0
D7 1 1 0
D6 0 0 0
D5 0 0 0
D4 1 0 0
D3 0 0 0
D2 1 0 0
D1 0 0 0
D0 1 0 0
Page 135
ECI Multi Functional Weighing Controller Operating Manual
Binary 2’ All
12495 kg -1780 kg ERROR
SIGN 0 1 1
D18 0 0 0
D17 0 0 0
D16 0 0 0
D15 0 1 0
D14 0 1 0
D13 1 1 0
D12 1 1 0
D11 0 1 0
D10 0 0 0
D9 0 0 0
D8 0 1 0
D7 1 0 0
D6 1 0 0
D5 0 0 0
D4 0 0 0
D3 1 1 0
D2 1 1 0
D1 1 0 0
D0 1 0 0
Page 136
ECI Multi Functional Weighing Controller Operating Manual
BinaryAbsolute
12495 kg -1780 kg ERROR
SIGN 0 1 1
D18 0 0 0
D17 0 1 0
D16 0 1 0
D15 0 0 0
D14 0 0 0
D13 1 0 0
D12 1 0 0
D11 0 0 0
D10 0 1 0
D9 0 1 0
D8 0 0 0
D7 1 1 0
D6 1 1 0
D5 0 1 0
D4 0 1 0
D3 1 0 0
D2 1 1 0
D1 1 0 0
D0 1 0 0
Page 137
ECI Multi Functional Weighing Controller Operating Manual
Service
This menu is used for making the control and testing of the inputs and outputs of the "BCD Module".
Inputs
The status of the inputs can be monitored real time
from this menu. The inputs that are applied 12-24 V
DC are displayed as 1 and others are displayed as
0.
Outputs
When key is pressed in this menu, one of the
outputs activate while the other remain inactive.
The active out is displayed as 1 and others are
displayed as 0.
Page 138
ECI Multi Functional Weighing Controller Operating Manual
Page 139
ECI Multi Functional Weighing Controller Operating Manual
Page 140
ECI Multi Functional Weighing Controller Operating Manual
8 Calibration
8.1 Load Calibration
It is the operation of identification of a mass with a known weight to the device. It must be made by using real
weights.
Page 141
ECI Multi Functional Weighing Controller Operating Manual
If you select the cell type wrong you can return the previous screen
by pressing key.
Page 142
ECI Multi Functional Weighing Controller Operating Manual
Page 143
ECI Multi Functional Weighing Controller Operating Manual
Page 144
ECI Multi Functional Weighing Controller Operating Manual
Page 145
ECI Multi Functional Weighing Controller Operating Manual
Page 146
ECI Multi Functional Weighing Controller Operating Manual
Page 147
ECI Multi Functional Weighing Controller Operating Manual
Page 148
ECI Multi Functional Weighing Controller Operating Manual
Page 149
ECI Multi Functional Weighing Controller Operating Manual
6) Coefficient value is entered. For confirming the value entered press key.
For example;
Load Cell Type: is selected as 2.0 mV/V and if the load
cell of 10 kg with the output of 2.0 mV/V is fully loaded, the
screen value will be 10000 for the coefficient=1,562500
Other sample values will be as shown in the following table
Page 151
ECI Multi Functional Weighing Controller Operating Manual
Page 152
ECI Multi Functional Weighing Controller Operating Manual
Page 153
ECI Multi Functional Weighing Controller Operating Manual
Page 154
ECI Multi Functional Weighing Controller Operating Manual
Page 155
ECI Multi Functional Weighing Controller Operating Manual
Page 156
ECI Multi Functional Weighing Controller Operating Manual
9 Software Update
EECI, provides software update support by using USB disk.
Warning: You may lose your existing settings after the device software update. Thus please review the changes
brought by the update carefully and store/note old settings if necessary. The outputs (Relay, input etc) connected to
the device may behave different as the routine operation of the device will be disabled during the software update.
Thus it is recommended to disconnect or shutdown the connectors connected to the device.
The following steps must be followed in order for the software update;
Page 157
ECI Multi Functional Weighing Controller Operating Manual
Page 158
ECI Multi Functional Weighing Controller Operating Manual
3) When the device is supplied power by keep pressing to the calibration key by means of a clip or stable, the
software update operation will start.
USB Input
Calibration Key
The LCD screen will be blank when the update starts. Do not cut the power of the device and wait during the
update. When the operation is completed the device will start operating automatically.
Page 159
ECI Multi Functional Weighing Controller Operating Manual
4) The version number is the start screen must be control in order to verify that the installation after the
update is performed.
Page 160
ECI Multi Functional Weighing Controller Operating Manual
Page 161
ECI Multi Functional Weighing Controller Operating Manual
Page 162
ECI Multi Functional Weighing Controller Operating Manual
Page 163
ECI Multi Functional Weighing Controller Operating Manual
Page 164
ECI Multi Functional Weighing Controller Operating Manual
Page 165
ECI Multi Functional Weighing Controller Operating Manual
10.1.2 E-MDL-PRF
10.1.2.1 Connection Example
Page 166
ECI Multi Functional Weighing Controller Operating Manual
Page 167
ECI Multi Functional Weighing Controller Operating Manual
Page 168
ECI Multi Functional Weighing Controller Operating Manual
Page 169
ECI Multi Functional Weighing Controller Operating Manual
External Supply
Page 170
ECI Multi Functional Weighing Controller Operating Manual
0-10 V Analogue
External Supply
External Supply
Page 171
ECI Multi Functional Weighing Controller Operating Manual
Page 172
ECI Multi Functional Weighing Controller Operating Manual
Page 173
ECI Multi Functional Weighing Controller Operating Manual
10.4.1.2 Connections
Page 174
ECI Multi Functional Weighing Controller Operating Manual
Page 175
ECI Multi Functional Weighing Controller Operating Manual
Output Connector
10.4.2.2 Connections
Page 176
ECI Multi Functional Weighing Controller Operating Manual
Page 177
ECI Multi Functional Weighing Controller Operating Manual
Page 178
ECI Multi Functional Weighing Controller Operating Manual
Page 179
ECI Multi Functional Weighing Controller Operating Manual
Page 180
ECI Multi Functional Weighing Controller Operating Manual
16) When the discharge input is detected, it is waited for the discharge delay period. (1.5 sec)
17) The discharge output is activated
18) When the weight value <(Tare-Zero Stripe), it is waited for the closing delay. (500ms)
19) The discharge become passive.
20) Stagnancy is waited.
21) If the number of batches is finished, then the operation is finalized.
22) If the number of batches is not finished, Ready input is waited.
23) It is repeated from step 2.
Note:
If, during the operation, any stop entry is observed or stop key is pressed, then the batching operation is terminated.
If there is no change about 10 scale intervals during the fast or slow filling periods, silo time lapse error is given.
Page 181
ECI Multi Functional Weighing Controller Operating Manual
Page 182
ECI Multi Functional Weighing Controller Operating Manual
Page 183
ECI Multi Functional Weighing Controller Operating Manual
Page 184
ECI Multi Functional Weighing Controller Operating Manual
11.2.2 Keys
Reset Key Used for resetting the display.
Batching Start Key Starts filling operation.
It is used for quick accessing to the recipe selection and total filling
Recipe Key
value selection menus for the filling operation.
It is used for bringing the menu where the settings related to the
Batching Menu Key
batching are made.
Setting Menu Key Used for bringing the menu screen where the device settings are made.
Pause Key Used for pausing the operation during the filling.
Stop Key It is used for terminating the filling operation.
Page 185
ECI Multi Functional Weighing Controller Operating Manual
Page 186
ECI Multi Functional Weighing Controller Operating Manual
Page 187
ECI Multi Functional Weighing Controller Operating Manual
Page 188
ECI Multi Functional Weighing Controller Operating Manual
Name
It is used for changing the recipe name.
RECIPE02
Formula
Name
…
…
…
RECIPE16
Note: Other recipes are adjusted as the Recipe1
Page 189
ECI Multi Functional Weighing Controller Operating Manual
Silo Settings
SILO01
Name
Used for determining/changing the silo name.
Sensitive Quantity
The weight value to be filled slowly. For example if
500g to be taken from the respective silo and 200g is
entered as the sensitive quantity, 300 g is quick filled.
200 g is slow filled.
Note: The transition value from the Quick filling to Slow filling may
vary depending on the shot value.
Shot Value
When the screen value approaches to the Target
Value with the value stated here,the filling stops It is
the quantity of the material hang.
Note: This step is not visible when it is "On" in Automatic Shot Menu
Page 190
ECI Multi Functional Weighing Controller Operating Manual
SILO02
Same as the Silo01 settings.
SILO03
Same as the Silo01 settings.
.
.
.
SILO16
Same as the Silo01 settings.
Page 191
ECI Multi Functional Weighing Controller Operating Manual
Start-up Setting
It is an ordered type menu that contains the start-up settings for the batching program.The sub-menus are the
Silo Number,Scale Capacity, Automatic Shot,Zero Stripe, Recipe Tolerance and RecipeComp.
Silo Number
It is used for identifying the number of silos in the system.
The options are;
1) 1
2) 2
3) 3
4) .
5) .
6) .
F)15
G)16
Note: If there is not -MDL-EXP Module in Slot 6, 4 silo, 5 silo,.....16 silo options are locked.
Page 192
ECI Multi Functional Weighing Controller Operating Manual
Scale capacity
It is the maximum weight value determined for the
batching. If the total quantity intended to be batched is
greater than the "Scale Capacity", more than one filling is
made by dividing as multipliers of the Scale Capacity.
It is also used as the limit of the reservoir that is filled.
Thus, no filling with the quantity more than the value
stated in this parameter will be made to the scale.
Auto Shot
The weight value hang after the valve is closed is
calculated automatically. When this parameter is selected
"On" the error made on the target quantity of the silo is
corrected automatically.
The options are;
1) Off: Error correction is made manually
2) On: Error correction is made automatically.
Page 193
ECI Multi Functional Weighing Controller Operating Manual
Zero Stripe
During the discharge, it is the value where it is
determined that the discharge operation is over. When
the weight value reduces under this quantity, the
discharge operation is considered done. It is used for the
material stuck to the scale.
RecipeTolerance
It is the maximum error allowed per silo. If this value is
exceeded, the device gives error and related relay output
is activated. It is valid for all silos in the recipe. In case of
false filling from any silo, the error output is activated. If
no error signal is wanted, it must be entered as 0
(deactivated).
Page 194
ECI Multi Functional Weighing Controller Operating Manual
RecipeComp
In batches made subsequently, it determines whether the
error made in previous batches are compensated or not.
Time Settings
This menu is an ordered type menu where the timing settings are made for the batching program. The sub-
menus are StartDelay,Stability.Delay and FillingTimeLapse.
StartDelay
It determines how much time after pressing the key
will the filling operations start and also the transition
period between the silos.
Page 195
ECI Multi Functional Weighing Controller Operating Manual
StabillityDelay
The weighing values during the period indicated in this
parameter are not taken into account and the device does
not change its state in order to prevent the
mismeasurements resulting from the vibration just after
the start of the quick filling and shifting from the quick
filling to the slow one. (Default value is 0 sec)
FillingTimeLapse
It is the maximum period that lapses during which the
weight value does not change at least 10*0 (Resolution)
during batching. The device gives error if this period is
exceeded. If no material is received although the material
intake has started, it is used for giving warning. If no error
signal is wanted, it must be entered as 0 sec
(deactivated).
Page 196
ECI Multi Functional Weighing Controller Operating Manual
Note: You can find information related to the usage of the Batching Configurator in Annex 4
Page 197
ECI Multi Functional Weighing Controller Operating Manual
Printer Settings
It is the menu where the printer settings are made.
Line Selections
Line 1
The data intended to be printed in line 1 is selected
The options are;
Page 198
ECI Multi Functional Weighing Controller Operating Manual
13) Last Filling: In Line 1 the quantity of the last filling is printed.
14) Grand total: In Line 1 total batching quantity is printed.
15) Barcode: In Line 1 Barcode is printed.
16) Line Space: It is used for spacing in line 1.
17) Page Break: It is used for breaking the page is line 1.
Line 2
Same as Line 1 menu.
Line 3
Same as Line 1 menu.
.
.
.
.
.
Line 16
Same as Line 1 menu.
Page 199
ECI Multi Functional Weighing Controller Operating Manual
Templates
Bold Text 1
Bold Text 1 template is indicated.
Bold Text 2
Bold Text 2 template is indicated.
Text 1
Text 1 template is indicated.
Text 2
Text 2 template is indicated.
Text 3
Text 3 template is indicated.
Text 4
Text 4 template is indicated.
Text 5
Text 5 template is indicated.
Text 6
Text 6 template is indicated.
Barcode: Barcode template is indicated.
Page 200
ECI Multi Functional Weighing Controller Operating Manual
Report
METER, TOTAL and LAST FILLING values can be
displayed. These values can be resetted if requested.
Key is used for manual printing the report screen.
Note: If the "Printer" option is not selected in Terminal Serial Output Mode menu, the key is not displayed in the
report screen.
Page 201
ECI Multi Functional Weighing Controller Operating Manual
Page 202
ECI Multi Functional Weighing Controller Operating Manual
When “custom->” option is selected, the Recipe No screen appears and the desired recipe can be
selected by entering the number.
Page 203
ECI Multi Functional Weighing Controller Operating Manual
Target Value
It is the quantity of the intended batching.
Page 204
ECI Multi Functional Weighing Controller Operating Manual
11.6.1 Up to 4 Silos
E-MDL-RLY module must be inserted in Slot 4. Other than this, the presence of E-MDL-RLY in Slot 5 or
E-MDL-EXP+EsRelay in Slot 6 is sufficient. If there is E-MDL-RLY module in Slot 5 and E-MDL-EXP+EsRelay
module in Slot 6, the E-MDL-EXP+EsRelay module in Slot 6 is used for Batching.
11.6.2 Up to 16 Silos
E-MDL-RLY module must be inserted in Slot 4.
E-MDL-EXP+EsRelay module must be inserted in Slot 6
Page 205
ECI Multi Functional Weighing Controller Operating Manual
Page 206
ECI Multi Functional Weighing Controller Operating Manual
Page 207
ECI Multi Functional Weighing Controller Operating Manual
Page 208
ECI Multi Functional Weighing Controller Operating Manual
If there is no E-MDL-EXP Module in Slot 6, the relay module in Slot 5 is used for batching.
Page 209
ECI Multi Functional Weighing Controller Operating Manual
Page 210
ECI Multi Functional Weighing Controller Operating Manual
Page 211
ECI Multi Functional Weighing Controller Operating Manual
In order the make the application the ratios of each of the silos defined above in the mixture are determined.
This operation is called recipe creation .
As an application of the recipe, make the mixture with 3 units of coffee, 1 unit of Sugar and 1 unit of cream.
Page 212
ECI Multi Functional Weighing Controller Operating Manual
Page 213
ECI Multi Functional Weighing Controller Operating Manual
11.6.4.1 Operation
After making the settings and system identification, the recipe is selected by pressing key at
batching main screen and the total batching value is entered.
Recipe Selection
It is used for selecting recipe. The options are;
1) RECIPE01
2) RECIPE02
3) .
4) .
5) .
6) RECIPE15
7) RECIPE16
After selecting the recipe key is pressed and Total selection menu is displayed.
Total
It is used for setting the total batching quantity.
Page 214
ECI Multi Functional Weighing Controller Operating Manual
Page 215
ECI Multi Functional Weighing Controller Operating Manual
Page 216
ECI Multi Functional Weighing Controller Operating Manual
Page 217
ECI Multi Functional Weighing Controller Operating Manual
Page 218
ECI Multi Functional Weighing Controller Operating Manual
Page 219
ECI Multi Functional Weighing Controller Operating Manual
Note:*Bag Handling Output is activated when Bag handling input is detected in any time
Bag handling input is passive for 1 sec after the moment of releasing the bag
Page 220
ECI Multi Functional Weighing Controller Operating Manual
Page 221
ECI Multi Functional Weighing Controller Operating Manual
Page 222
ECI Multi Functional Weighing Controller Operating Manual
12.3.2 Keys
Page 223
ECI Multi Functional Weighing Controller Operating Manual
Page 224
ECI Multi Functional Weighing Controller Operating Manual
Page 225
ECI Multi Functional Weighing Controller Operating Manual
1.Product Setting 2. Start-up Setting 3. Control setting 4. Time Setting 5. Printer Setting 6.Report
1.1.FILL 01 Filling Type Control Mode Start. Delay 5.1.Line Selections
1.2.FILL 02 Filling Mode Shot Value DischargeDelay 5.2.Templates
1.3.FILL 03 Feeding Mode Sensitive BagHand.Wait 5.3.Printerl Mode
1.4.FILL 04 Quick Feeding Quantity FillingTimeLapse
1.5.FILL 05 Auto Tare Multiplication
1.6.FILL 06 Zero Stripe Period
1.7.FILL 07 Scale Capacity
1.8.FILL 08 ToleranceCont.
1.9.FILL 09 Tare Control
1.A.FILL 10 UserLev.
1.B.FILL 11
1.C.FILL 12
1.D.FILL 13
1.E.FILL 14
1.F.FILL 15
1.G.FILL 16
Page 226
ECI Multi Functional Weighing Controller Operating Manual
Product Name
Product name is set.
Target Value
The quantity intended for filling is set.
Page 227
ECI Multi Functional Weighing Controller Operating Manual
Page 228
ECI Multi Functional Weighing Controller Operating Manual
Lower Tolerance
The error quantity accepted below the target value is
indicated. For example if the quantity to be filled is
1000g and acceptable lower limit is 990 g, it is
necessary to enter 1000-990=10 g in the Lower
Tolerance menu.
Upper Tolerance
The error quantity accepted above the target value is
indicated. For example if the quantity to be filled is
1000g and acceptable upper limit is 1015 g, it is
necessary to enter 1015-1000=15 g in the Upper
Tolerance menu.
Page 229
ECI Multi Functional Weighing Controller Operating Manual
Minimum Tare
Indicates the lower limit used for the Tare Control.
Maximum Tare
Indicates the upper limit used for the Tare Control.
Page 230
ECI Multi Functional Weighing Controller Operating Manual
Page 231
ECI Multi Functional Weighing Controller Operating Manual
Start-up Setting
It is the menu for the start-up settings of the filling program. This menu is an ordered type menu. Sub-menus
are Filling Type, Filling Mode, Feeding Mode, Quick Feeding, Auto Tare, Zero Zone, Tolerance Control, Tare
Control ve UserLev.
Filling Type
The options are;
1) Increasing Weighing: It is the filling system in
which the load cell is connected to the scale to be
filled.
2) Descending Weighing: It is the filling system in
which the load cell is connected to the silo.
Filling Mode
The options are;
1) Bag Filling: The good in the silo is filled to the bag
under control.
2) Scale Filling: Filling is made primarily into the scale.
Then it is transferred to the bag.
Page 232
ECI Multi Functional Weighing Controller Operating Manual
Feeding Mode
The filling can be performed with single or double speed.
The options are;
1) Quick: Single speed filling is made.
2) Quick+Slow: Double speed filling is made.
Quick Feeding
When the feeding mode is selected as "Quick+Slow",
quick feeding (rough filling) can be made with single or
double relay. The options are;
1) Simultaneous: Double relay (Slot4 Relay1+ Slot4
Relay2)
2) Serial: Single relay (Slot4 Relay1)
Note:This menu is not displayed when "Quick" is selected in the "Feeding Menu"
Page 233
ECI Multi Functional Weighing Controller Operating Manual
Auto Tare
When the filling operation starts,the screen value may be
resetted temporarily. The options are;
1) On:
2) Off:
Zero Stripe
The filling scale is assumed empty under the value stated
herein.
Page 234
ECI Multi Functional Weighing Controller Operating Manual
Scale capacity
It is the maximum weight value determined for the filling.
ToleranceCont.
If the filling is outside the lower and upper tolerances
requested, warning can be made over the respective
relay outputs. The options are;
1) Off:
2) On:
Note: Lower and Upper Tolerance menus are under "Product settings" menu.
Page 235
ECI Multi Functional Weighing Controller Operating Manual
Tare Control
When the filling operation is started, if the weight value is
outside the Minimum Tare and Maximum Tare range, the
device may give error and not start. The options are;
1) Off:
2) On:
Note: Minimum Tare and Maximum Tare menus are under "4.Product settings" menu
UserLev.
The options are;
1) Basic: Multiplication Period menu is close.
2) Advanced: Multiplication Period menu is open.
Page 236
ECI Multi Functional Weighing Controller Operating Manual
Control setting
It is the menu where the filling control settings are made.
Control Mode
The options are;
1) Full Automatic: Sensitive Quantity ve Shot Value are
calculated automatically.
2) Auto Shot: Shot Value is calculated automatically.
3) Manuel:Sensitive Quantity ve Shot Value are
determined by the user.
Note:Full Automatic option is not displayed when "Quick" is selected in the "Feeding Menu"
Shot Value
When the screen value approaches to the Target Value
with the value stated here,the filling stops.
Note:This menu is not displayed if "Auto Shot" or "Full Automatic" is selected in "Control Mode" menu.
Page 237
ECI Multi Functional Weighing Controller Operating Manual
Sensitive Quantity
It is the weight value to be filled slowly. For example if
500g to be taken from the respective silo and 100g is
entered as the sensitive quantity, 400 g is quick filled. 100
g is slow filled.
Note:This step is not displayed when "Quick" is selected in the "Feeding Menu"
Multiplication Period
The period in which no weight control to be made after the
quick filling finishes is indicated.
Note: When "Basic" is selected in "UserLev." menu or "Quick" is selected in "Feeding Mode" menu, this step is not
displayed.
Page 238
ECI Multi Functional Weighing Controller Operating Manual
Time Setting
Start. Delay
The delay period before start filling.
DischargeDelay
The waiting period before start discharging.
Page 239
ECI Multi Functional Weighing Controller Operating Manual
BagHand.Wait
The waiting period before the Bag Handling Output is
deactivated after the completion of the filling operation.
Note:This step is not visible if "Bag Filling" is selected in "Filling Mode menu.
FillingTimeLapse
The device gives error if this period is exceeded without
changing the weight value during filling.
.
Page 240
ECI Multi Functional Weighing Controller Operating Manual
Printer Setting
It is the menu where the printer settings are made.
Line Selections
Line 1
The data intended to be printed in line 1 is selected.
The options are;
Page 241
ECI Multi Functional Weighing Controller Operating Manual
Page 242
ECI Multi Functional Weighing Controller Operating Manual
Templates
Bold Text 1
Bold Text 1 template is indicated.
Bold Text 2
Bold Text 2 template is indicated.
Text 1
Text 1 template is indicated.
Text 2
Text 2 template is indicated.
Text 3
Text 3 template is indicated.
Text 4
Text 4 template is indicated.
Text 5
Text 5 template is indicated.
Text 6
Text 6 template is indicated.
Barcode: Barcode template is indicated.
Page 243
ECI Multi Functional Weighing Controller Operating Manual
Report
METER, TOTAL and AVERAGE values can be displayed.
These values can be resetted if requested. Key is
used for manual printing at the report screen.
METER: Total number of filling. Resets when the product is changed and the device is restarted.
TOTAL: Total quantity of the filling.
AVERAGE: Average quantity of the filling.
Note: If the "Printer" option is not selected in Terminal Serial Output Mode menu, the key is not displayed in the
report screen.
Page 244
ECI Multi Functional Weighing Controller Operating Manual
Page 245
ECI Multi Functional Weighing Controller Operating Manual
Page 246
ECI Multi Functional Weighing Controller Operating Manual
Slot4 E-MDL-RLY Module Input Connections Slot5 E-MDL-RLY Module Input Connections
Page 247
ECI Multi Functional Weighing Controller Operating Manual
Page 248
ECI Multi Functional Weighing Controller Operating Manual
Page 249
ECI Multi Functional Weighing Controller Operating Manual
Slot4 E-MDL-RLY Module Output Connections Slot5 E-MDL-RLY Module Output Connections
Page 250
ECI Multi Functional Weighing Controller Operating Manual
Page 251
ECI Multi Functional Weighing Controller Operating Manual
Page 252
ECI Multi Functional Weighing Controller Operating Manual
Page 253
ECI Multi Functional Weighing Controller Operating Manual
Page 254
ECI Multi Functional Weighing Controller Operating Manual
Page 255
ECI Multi Functional Weighing Controller Operating Manual
Page 256
ECI Multi Functional Weighing Controller Operating Manual
Page 257
ECI Multi Functional Weighing Controller Operating Manual
Page 258
ECI Multi Functional Weighing Controller Operating Manual
Page 259
ECI Multi Functional Weighing Controller Operating Manual
Page 260
ECI Multi Functional Weighing Controller Operating Manual
Page 261
ECI Multi Functional Weighing Controller Operating Manual
7) After entering the Table name from the new Table window click button and open the table screen.
Page 262
ECI Multi Functional Weighing Controller Operating Manual
Page 263
ECI Multi Functional Weighing Controller Operating Manual
Page 264
ECI Multi Functional Weighing Controller Operating Manual
Page 265
ECI Multi Functional Weighing Controller Operating Manual
Page 266
ECI Multi Functional Weighing Controller Operating Manual
BIT(s) Function
0-3 (/O) Program Mode: 0: Indicator, 1: Batching, 2: Filling, 3: PLC, 4-15:Out of use
4-8 (/O) (5bits) Out of use
9 (/O) 1:No load cell module inserted or it is not working, 0:load cell module is working.
10 (/O) 1:ADC input voltage over detected. It must be cleaned by the user.
11 (/O) Out of use
12 (/O) 1:ADC input voltage is very high. It is 0 when the value returns to normal.
Abnormal system operation flag. Set as 1 when wrong operation occurs. It means that the
13(Y/O)
system has been restarted due to the electricity problems.
14-15 (2bits) Out of use
Page 267
ECI Multi Functional Weighing Controller Operating Manual
BIT(s) Function
Scale Interval. (1, 2, 5 x10^n )
0-6 (/O) (7bits) 1:1, 2:2, 5: 5, 10:10, 20:20, 50:50, 100:100
101:200, 102:500, 103:1000, 104:2000, 105:5000
7 (/O) Slot 4 Relay 1 On/Off Status. 1:On, 0:Off
8-10 (/O) (3bits) This value shows on which digit from right will the point be. It can be 3 maximum
11-14 (/O) (4bits) Unit (0:g, 1:Kg, 2:t, 3:N, 4:lb, 5:lt, 6:mV, 7:m3 , 8:None)
15 (/O) Slot 4 Relay 2 On/Off Status. 1: On, 0: Off
Page 268
ECI Multi Functional Weighing Controller Operating Manual
BIT(s) Function
0-2 (RW) (3bits) Load Cell Type. 0: 2mV/V, 1: 2.5mV/V, 2: 5mV/V, 3: 10mV/V, 4: 20mV/V, 5: 160mV/V
3-4 (RW) (2bits) Out of use
5 (/O) 1:Error, 0: No Error
6 (/O) 1: Calibration is possible, 0: No calibration is possible.
7 (/O) Communication lock. 1:On 0:Off
8 (/O) 1:On device menu screen, 0: On Device main screen
9 (/O) 1: Absolute Zero yes, 0: Absolute Zero no
10 (/O) 1: Stagnancy, 0:Mobility
11 (/O) 1:Maximum load yes, 0: Maximum load no
12 (/O) 1:e2 zone
13 (/O) 1:e3 zone
14 (/O) Out of use
15 (RW) Measuring Type. 1:Multi Partition or Multi Interval, 0:Single Partition
Page 269
ECI Multi Functional Weighing Controller Operating Manual
Page 270
ECI Multi Functional Weighing Controller Operating Manual
Page 271
ECI Multi Functional Weighing Controller Operating Manual
Page 272
ECI Multi Functional Weighing Controller Operating Manual
Page 273
ECI Multi Functional Weighing Controller Operating Manual
14.5 Examples:
14.5.1 Reading more than one register.
Such that Modbus ID:1, in order to read the data from register no 8 to register no 14
following data array is sent.
Byte
Modbus Function Screen Screen Tare Tare Gross Gross CRC
Numb
ID Code Top Bottom Upper Lower Upper Lower Data
er
01 03 0C 00 00 01 F4 00 00 00 64 00 00 02 58 85 23
Accordingly
Screen Value=0x000001F4=500
Tare Value=0x00000064=100
Page 274
ECI Multi Functional Weighing Controller Operating Manual
Gross Value=0x00000258=600
Page 275
ECI Multi Functional Weighing Controller Operating Manual
Page 276
ECI Multi Functional Weighing Controller Operating Manual
Byte Comman
Modbus Function Start Register
Numb d Reg A Reg B CRC Data
ID Code Address Number
er Register
01 10 00 00 00 03 06 00 01 13 57 21 92 F7 E9
Page 277
ECI Multi Functional Weighing Controller Operating Manual
Byte Comman
Modbus Function Start Register
Numbe d Reg A Reg B CRC Data
ID Code Address Number
r Register
01 10 00 00 00 03 06 00 02 00 2F 00 01 6F 49
NOTE: As a matter of course, when a value is written to the EEPROM section, only the EEPROM
daat changes. There are two ways to update the RAM values with the EEPROM values;
1-) It is necessary to disconnect, then connect the power.
2-) 0x0A Command must be executed over Modbus. (0x0A: update parameters from EEPROM)
Page 278
ECI Multi Functional Weighing Controller Operating Manual
Value Function
No operation It is used for feedback. Command denied. (This operation cannot be performed under the
-2
current status.)
-1 No operation It is used for feedback. It means that last operation is not successful.
0 No operation It is used for feedback. It means that last operation is successful.
1 Unlocking Communication lock It is used for writing data on EEPROM.
2 Writing to EEPROM, data should be written to RegB and address should be written to RegA.
3 Reading from EEPROM:Address should be written to RegA. Data is place to RegB.
5 Reset: Used for resetting the screen value.
6 Tare: Tare the screen value. (If the screen value is not 0 or negative)
7 Learning the Communication Lock: To Both RegA and RegB
8 Device Type: Data is written to RegA. ECI Family: 3000
9 Version No: Data is written to RegA.
10 Transfer device parameters from EEPROM to RAM.
12 Clean the error bits
Page 279
ECI Multi Functional Weighing Controller Operating Manual
Page 280
ECI Multi Functional Weighing Controller Operating Manual
Examples
14.6.1 Taring
0x06 is written to the Command register for Taring. (Modbus ID:2 was used)
Page 281
ECI Multi Functional Weighing Controller Operating Manual
When the operation is performed, the same of the data string sent is returned.
When the operation is performed, the same of the data string sent is returned.
Page 282
ECI Multi Functional Weighing Controller Operating Manual
Page 283
ECI Multi Functional Weighing Controller Operating Manual
Page 284
ECI Multi Functional Weighing Controller Operating Manual
Page 285
ECI Multi Functional Weighing Controller Operating Manual
Page 286
ECI Multi Functional Weighing Controller Operating Manual
Page 287
ECI Multi Functional Weighing Controller Operating Manual
Page 289
ECI Multi Functional Weighing Controller Operating Manual
Page 290
ECI Multi Functional Weighing Controller Operating Manual
Page 291
ECI Multi Functional Weighing Controller Operating Manual
Page 292
ECI Multi Functional Weighing Controller Operating Manual
Page 294
ECI Multi Functional Weighing Controller Operating Manual
Warning 102 Tare active! No zeroing can be made while the tare is active.
Warning 103 Negative Load No taring can be possible for the negative loads.
Warning 104 No taring possible No taring can be possible for the zero value.
RestoreFact.Setting
Warning 108 Factory Settings will be restored.
s
Warning 109 Restarting The device will be restarted.
Filling or discharging valves can be opened by activating the units connected
Warning 110 Output will change
to the relay outputs.
It shows that no weight change occurs during the "FillingTimeLapse" period
Warning 120 FillingTimeLapse
while filling.
It is shown when the maximum batching value of 100.000 for silo is
Warning 121 SiloValue Max
exceeded.
Warning 122 SiloValue Min It is shown when the maximum batching value of 0 for silo is calculated.
Warning 123 InsufficientCapacity Batching value is more than the capacity.
Warning 124 Total < Package Total value of the batching cannot be less than the package value.
The filling operation is unable to be started as the weight values for the silo
Warning 125 Recipe Empty!
related to the recipe intended to be batched is entered as zero.
Errors more than detected occurred at any of the silos as the result of
Error 126 ToleranceError!
batching.
Discharge.TimeLap It shows that no weight change occurs during the "FillingTimeLapse" period
Error 127
se while discharging.
Page 297
ECI Multi Functional Weighing Controller Operating Manual
It is shown when the module required for performing the operation is not
Warning 130 No Hardware!
present.
Warning 131 Missing Module Additional module is required for the batching operation.
Informatio Product has
224 Product to be filled has been changed.
n Changed!
Informatio
200 Stored New parameter value has been stored to the memory.
n
Informatio
201 Please wait... It is displayed during the long operations.
n
Informatio
207 vX.Y It is the version number screen. X:Major, Y:Minor
n
Informatio
208 Cancelled! Parameter change has been cancelled.
n
Informatio
211 It is the terminal serial port test screen.
n
Informatio
212 It is the remote display output test screen.
n
Informatio
213 It is the E-MDL-COM module serial port test screen.
n
Informatio
220 Stopped. Batching operation has been cancelled.
n
Page 298
ECI Multi Functional Weighing Controller Operating Manual
Informatio No product can be selected from the menu when one of the product
223 ExternalSelecActive
n selection attempts is active.
Informatio
230 Memory-1 OK Memory unit has been tested successfully.
n
Informatio
231 Memory-2 OK Memory unit has been tested successfully.
n
Informatio
232 Backing-up... Calibration parameters will be copies to E-ECI-LC card.
n
Informatio
233 Receiving... Calibration parameters in E-ECI-LC card will be uploaded to the main card.
n
Informatio
255 Setting... It is shown when key sensitivity is set.
n
Page 299