MT-600/8000 series
MT-607i
                                                             MT-8070iH / MT-6070iH
                                                             Installation Instruction
             1.0 Installation and Startup Guide
             Install Environment
              Where                  The MT-600/8000 Series is designed for industrial. The temperature range of operating
              Used                   is from 32 to 113 °F (0 to 45 °C), as majority of industrial environments. It may not be
                                     suitable for using in certain outdoor applications. Please consult the factory for
                                     advised usage in outdoor applications.
              NEMA                   The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a
              Rating
                                     NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means
                                     that fluids will not enter the panel during wash downs.
              Electrical             The MT-600/8000 Series has been tested to conform to European CE requirements.
              Environment
                                     This means that the circuitry is designed to resist the effects of electrical noise. This
                                     does not guarantee noise immunity in severe cases. Proper wire routing and
                                     grounding will insure proper operation.
              Mechanical             Avoid installing units in environments where severe mechanical vibration or shocks
              Environment
                                     are present.
             2.0 Installation Instructions
             2.1 Mounting Instructions
             2.1.1 Location Considerations
                Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC
              output modules, contactors, starters and relays, and any other source of electrical interference are located
              away from the back of the unit.
                Particular note should be taken to the position of variable speed drives and switching power supplies.
              Their input and load cables should be screened to a central star earth point.
Downloaded from www.Manualslib.com manuals search engine
             2.1.2 Making a NEMA-4 Mounting
              Panel       The unit can be mounted into panels with a depth of 4”(105mm). It is recommended that
              Details     the unit be mounted on the front panel of a steel enclosure, through an appropriate opening.
                                 Allow a clearance of 1”(25mm) around the sides of the unit for mounting hardware. Allow
                                 clearance for cable connections to the back of the unit. Unit depth may vary according to
                                 cable type used. Typically, plan a depth to accommodate at least 4”(105mm) behind the
                                 panel.
              NEMA-4             Put the unit through the panel cut out. Slide the clamps into the 4 holes provided around
              Mounting           the case. Tighten the clamping screws in an even pattern until the unit is secured in the
                                 panel.
              Caution!           Do not over tighten mounting clamps!
              Note:          Specifications
                                 Note: To seal to NEMA-4 specifications, all supplied mounting clamps must be used and
                                 panel cannot flex more than 0.010”.
             2.1.3 Environmental Considerations
                             z     The MT-600/8000 are to be used indoors as built in displays. Make sure that the displays
                                   are installed correctly and that the operating limits are followed (See Specifications).
                             z     Do not operate the unit in areas subject to explosion hazards due to flammable gases,
                                   vapors or dusts.
                             z     The unit should not be installed where fast temperature variations and/or high humidity
                                   are present. This will cause condensation of water in the device.
                             z     Do not install these terminals in environments where have inflammable gases.
             2.2 Power Connections
               Make sure that all local and national electrical standards are met when the installing the unit.
               Contact your local authorities to determine which codes apply.
             2.2.1 Power Requirements
                            Power                      The MT-600/8000 can be powered by DC power only. The specified
                                                       voltage range is 24±20% Volts DC. This insures compatibility with most
                                                       controller DC systems.
                                                       The power conditioning circuitry inside the unit is accomplished by a
                                                       switching power supply. The peak starting current can be as high as
                                                       700mA.
                            Fusing                     If the display does not come on within 5 seconds of power up, remove
                            Requirements               power. An internal fuse will prevent damage if the polarity of the DC
                                                       power is incorrect. Check wiring to insure proper connections and try to
                                                       power up again.
                            Caution                    An Internal fuse will prevent damage for over voltage condition however
                            High Voltage               it isn’t guaranteed.
                                                       DC voltage sources should provide proper isolation from main AC power
                                                       and similar hazards.
                            Caution                    A Hard-wired EMERGENCY STOP should be fitted in any system using
                            Emergency                  an MT-600/8000 to comply with ICS Safety Recommendations.
                            Stop
Downloaded from www.Manualslib.com manuals search engine
                            Caution                    Do not power the MT-600/8000 and inductive DC loads, or input
                            Supply Voltage             circuitry to the controller, with the same power supply. Note: The 24 VDC
                            Condition                  output from some controllers may not have enough current to power the
                                                       MT-600/8000.
                            Caution                    Wire lengths should be minimized (Maximum 1600’ (500 m) shielded,
                            Wire Routing               1000’ (300 m) unshielded).
                                                       Wires should be run in pairs with a neutral or common paired with a hot or
                                                       signal line.
                                                       If wiring is to be exposed to lightning or surges, use appropriate surge
                                                       suppression devices.
                                                       Keep AC, high energy, and rapidly switching DC wiring separate from
                                                       signal wires.
                                                       Equip ungrounded DC supplies with a resistor and capacitor in parallel to
                                                       earth ground. This provides a path for static and high frequency
                                                       dissipation. Typical values to use are 1MOhm and 4700pF.
                                                       To prevent the HMI from becoming damaged or having sound output
                            Caution                    issues, after turning the device off, please wait 10 seconds before turning
                                                       the device on again.
                            Connection   To make a connection, strip about 3/8” of insulation off the end of the
                                         wire, turn the connector screw counterclockwise until the gap is wide
                                         open, insert the wire all the way in, and turn the screw clockwise until it’s
                                         tight.
                                         Connect positive DC line to the ‘+24V’ terminal and the DC ground to the
                                         ‘0V‘ terminal.
             2.2.2 Grounding Requirements
                                     Chassis ground must be used. DC ground is not directly coupled to Earth
                                     ground internally. It is preferable not to ground DC negative return to chassis
                                     ground as poor site earths can introduce noise into a system, but if necessary
                                     an earth connection should be made, from the power supply return point to
                                     the central star earth point. Ground conductors should be as short and as large
                                     in size as possible. The conductors must always be large enough to carry the
                                     maximum short circuit current of the path being considered. Ground
                                     conductors should be connected to a tree from a central star earth ground
                                     point. This ensures that no ground conductor carries current from any other
                                     branch.
             2.2.3 CE Requirements
                       To make an MT-600/8000 comply with EMC directives, and to reduce susceptibility to electrical
                    interference, a separate #14 AWG ground wire should be taken to the chassis ground terminal of the
                    power connector. This ground connection should be run directly to the central star earth connection
                    point (as recommended in most Installation Instructions).
             2.2.4 Safety Guidelines
                     This section presents recommended installation practices, and procedures. Since no two
                  applications are identical, these recommendations should be considered as guidelines.
              Hardware                             WARNING!
              Considerations
                                                   The system designer should be aware that devices in Controller systems could
                                                   fail and thereby create an unsafe condition. Furthermore, electrical
                                                   interference in an operator interface, such as an MT-600/8000, can lead to
                                                   equipment start-up, which could result in property damage and/or physical
                                                   injury to the equipment operator.
                                                   If you, or your company, use any programmable control systems that require
                                                   an operator or attendant, you should be aware that this potential safety hazard
                                                   exists and take appropriate precautions. Although the specific design steps
                                                   depend on your particular application, the following precautions generally
                                                                           3
Downloaded from www.Manualslib.com manuals search engine
                                                   apply to installation of solid-state programmable control devices. In addition,
                                                   these precautions conform to the guidelines for installation of Controllers as
                                                   recommended in the NEMA ICS 3-304 Control Standards.
              Programming                           To conform with ICS Safety Recommendations, checks should be placed
              Considerations                        in the controller to ensure that all writable registers that control critical
                                                    parts of plant or machinery have limit checks built into the program, with
                                                    an out-of-limit safe shut down procedure to ensure safety of personnel.
             ICS 3-304.81 Safety Recommendations:
                       Consideration should be given to the use of an emergency stop function, which is independent of the programmable
                  controller.
                      Where the operator is exposed to the machinery, such as in loading or unloading a machine tool, or where the machine
                  cycles automatically, consideration should be given to the use of an electromechanical override or other redundant means,
                  independent of the programmable controller, for starting and interrupting the cycle.
                      If provision is required for changing programs while the equipment is in operation, consideration should be given to the
                  use of locks or other means of assuring that only authorized personnel can make such changes.
                      These recommendations are intended as safeguards against the failure of critical components and the effects of such
                  failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation. *
                   z The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical
                     Manufacturers Association from NEMA ICS 3-304
             2.3 Communications Connections
                    The ports as you look at the back of the case, are the ports for connecting to a PLC or some external
                  device (Controller Connectors).
             2.3.1 Connector COM1 [RS232], COM2 [RS232]
              Cable                               Different cables are required for various devices.
              Requirements
                                                  Restrict cable length to less than 500’ (150m) for RS485/422 devices and
              Caution                             50’ (15m) for RS232 devices to avoid communications problems.
                                                  The COM light on the front of the MT-600/8000 will turn on with each
                                                  Ethernet communication.
                                                  Shielded cable must be used for long lengths or cables run in an electrically
                                                  noisy environment.
                                                  Do not run cables next to AC power lines or near sources of electrical noise.
                                                  Be sure that the cable ends have been inserted all of the way into mating
                                                  connectors and are secure
              Pin Designations                    Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] and COM2
                                                  [RS-232] Port.
                                                    Pin#    Symbol         COM1 [RS232]                        COM2 [RS232]
                                                    1       Not used
              COM1 [RS-232]
              COM2 [RS-232]                         2       RxD            Received Data
                                                    3       TxD            Transmitted Data
                                                    4       TxD                                                Transmitted Data
                                                    5       GND                                     Signal Ground
                                                    6       RxD                                                Received Data
                                                    7       RTS            Ready to send output
                                                    8       CTS            Clear to send input
                                                    9       Not used
Downloaded from www.Manualslib.com manuals search engine
             2.3.2 Connector COM1[RS485] , COM3[RS485] and COM3[RS232]
                   The 9 Pin, Female, SUB-D, COM1 [RS-485] , COM3 [RS-485] and COM3 [RS-232] Port on the back
                of the unit is the RS-232 and RS485/422 communications port for connecting to a controller.
                Connection
                Pin Designations                     Pin assignment of the 9 Pin, Female, SUB-D COM1 [RS-485], COM3
                                                     [RS-485] and COM3 [RS-232] Port
                                                     Pin# Symbol Com1                Com1          Com3    Com3
                                                                     [RS485]2w       [RS485]4w [RS485]     [RS232]
                COM1 [RS-485]
                COM3 [RS-485]                         1     Rx-      Data-           Rx-
                COM3 [RS-232]                         2     Rx+      Data+           Rx+
                                                      3     Tx-                      Tx-
                                                      4     Tx+                      Tx+
                                                      5     GND                          Signal Ground
                                                      6     Data-                                  Data-
                                                      7     TxD                                            Transmit
                                                      8     RxD                                            Receive
                                                      9     Data+                                  Data+
             2.3.3 USB Host port
             Support various devices with USB 1.1 Host interface, such as mouse, keyboard, USB stick,
             printer…etc. It can use Mini USB cable (RZCMT6100) to download projects from PC by the USB 2.0 client
             port. Support USB 2.0 client interface. The cable regulation must accord with HI-SPEED USB Revision 2.0
             SHIELDED.
             How to install USB driver of HMI i series
             i Series HMI support the function of using Mini USB cable to download projects from PC. It is necessary to
             install USB driver of HMI on PC before at the first time enjoying this function. (The HMI models: MT6050i,
             MT6056i, MT6070iH, MT6100i, MT8070iH and MT8100i)
             1. Using USB cable mini side plug to HMI and another side plug into PC. The PC will display “Found New
                 Hardware Wizard” dialog. Select “Install from a list or specific location (Advanced)”.
             2. Check “Include this location in the search”, and assign the path to install Weintek HMI i Series driver
                 from C:\EB8000\usbdriver.
             3. If the USB driver successfully be installed, user can check it at Computer Management / Device Manager
                 to check. Then user can download project to HMI i series through USB cable.
             2.3.4 Connecter Wire
Downloaded from www.Manualslib.com manuals search engine
             MT8-Ethernet/RZC045120: Direct connect (Ethernet crossover cable)
             MT-600/8000                         PC or Note
             Ethernet RJ45 Wire color            Book RJ45
             1 TX+         White/Orange          3 RX+
             2 TX-         Orange                6 RX-
             3 RX+         White/Green           1 TX+
             6 RX-                Green                    2 TX-
             MT8-COM1/RZC002320                                      MT8-COM3/RZC004850
                                               5   9
                                                                                                      5   9
                                               1   6
                                                                                                      1   6
                 5
             9
             6                                                       6    1                           5   9
                 1
                                                                     9    5                           1   6
                                               5   9
                                                   6                                                  5   9
                                               1
                                                                                                      1   6
             2.3.5 Dip Switch
                                                            SW1    SW2        SW3   SW4 Mode
                                                            ON     OFF        OFF   OFF Touch Screen Calibrate mode
                                                            OFF    ON         OFF   OFF EB8000 System Tool Bar
                                                            OFF    OFF        ON    OFF Boot Loader mode
                                                            OFF    OFF        OFF   ON Reserve
                                                            OFF    OFF        OFF   OFF Normal
                                                                  z Touch Screen Calibrate and Reset Password mode: In
                                                                     this mode when you power on the MT8000 series, the
                                                                     screen will display a “+” sign at the center of the screen.
                                                                     Use a stylus or finger to push the center of the “+” until
                                                                     it moves. The “+” moves to upper-left, upper-right,
                                                                     lower -left, lower-right and center. When all five “+” are
                                                                     done the “+” will disappear. The Touch Screen
                                                                     parameter will store at Flash Rom.
                                                               z         If losing or forgetting system passwords, users can set
                                                                         Dip Switch 1 to “ON” position, the rest of Dips remain
                                                                         on “OFF” position and then reboot MT8000 series.
                                                                         Under this situation, MT8000 series will jump to Touch
                                                                         Adjust (Touch screen calibration) mode. After
                                                                         calibration, the pop-up window appears as the
                                                                         illustration below. Users will be inquired if restoring the
                                                                         system password to the default value.
                                                               z         When “YES” is chosen, another pop-up dialog appears
                                                                         as below. Users will be confirmed again if restoring the
                                                                         system password to the default value and will be asked
                                                                         to input “YES”. Then click OK. (The default password
                                                                         is 111111. However, other passwords, including
                                                                              6
Downloaded from www.Manualslib.com manuals search engine
                   download, upload password and History backup password, have to be reset.)
                  Note: When the reset action is be taken, projects and saved data in the HMI will all be cleared.
             2.4 CE Requirements
             EU directives that apply to the MT-600/8000 Series:
               z EMC Directive (2004/108/EC) electromagnetic emissions and immunity
               z UL508(ISBN 0-7629-0404-6)machine safety
               z MT-600/8000 products will be CE-marked to indicate compliance with the EMC Directive.
             The MT-600/8000 Series has been designed to operate satisfactorily in electromagnetic noise (immunity) and
             without emitting high levels of electrical noise into the environment (emission). The units are designed to
             meet European Community standards when installed per the wiring instructions in this manual.
             Compatibility The MT-600/8000 has been designed to meet electromagnetic compatibility for industrial
             Standards         environments.
                                z EN 55022: 2006 Class A
                                z EN 61000-3-2: 2006
                                z EN 61000-3-3: 1995+A1: 2001+A2: 2005
                                z EN 55024: 1998+A1: 2001+A2: 2003
             3.0 Specifications
                                                   MT6070iH                             MT8070iH                               MT607i
                                                                Hardware Specification
              Display                                                               7" TFT LCD
              Brightness                                                             300 cd/m2
              Color                                                                 65,536 colors
              Contrast Ratio                                                            500:1
              Resolution (WxH dots)                                                  800 x 480
              Back light                                                                LED
              Backlight life time (avg.)                                           30,000 hr. min.
              Touch panel                                                       4 wires resistive type
              Touch Accuracy                                        Active Area Length(X)±2%, Width(Y)±2%
              I/O port                                COM1 (RS-232/RS-485 2W/4W), COM2(RS232), COM3(RS-232/RS-485 2W)
              Ethernet port                           N/A                                       1 Ethernet port (10/100 Base-T)
              USB                                                     USB Host port x 1, USB Client port x 1
              Processor                                                      32bit RISC CPU 400MHz
              Flash memory                                                             128MB
              DRAM                                                         64MB DDR2 RAM on board
              SD card slot                            N/A                                                    YES
              Audio                                   N/A                                                    YES
              RTC                                                     Built-in (CR2032 3V lithium battery.)
                                                                 General Specification
              Input Power                                                            24±20% VDC
              Max Power Consumption                                    250 mA@24VDC Power Isolation Inside
              Protection structure                                           IP65 front panel (O ring seal)
              Storage Temperature                                               -20~60°C (-4° ~ 140°F)
              Operating Temperature                                              0~45°C (32° ~ 113°F)
              Operation humidity                                             10-90% RH (non –condense)
              Enclosure                                                                  Plastic
              Dimensions WxHxD                                                    200 x 146 x 42.5mm
              Panel cutout dimension                                           192 x 138 mm (7.5"x5.4")
              Weight                                                           Approx. 0.85 kg (1.87 lbs)
                                                                  Operating System
              Operating System                                EB8000 2.0.0 or Newer                                      Windows CE.net 5.0
Downloaded from www.Manualslib.com manuals search engine
             3.1 Limited Liability Warranty
                    Weintek products include the isolated power supply are covered by a limited liability warranty from
               defects in material and workmanship. This warranty does not apply:
               (a) if, in the judgment of Weintek, the product fails due to damage from shipment, handling, storage, accident
                    (natural and man-mad) ;
               (b) If the product fails due to misuse, including but not limit to incorrect set-up and wiring, current leakage
                    from machine platform and incorrect input power;
               (c) If the product has been maintained in a manner not conforming to product's instructions or has been
                    modified in any way,
               (d) If the serial number has been defaced or removed.
             4.0 Dimensions of MT-607i / MT-6070iH /
                MT-8070iH
                                                                                          Bottom View
                                            Front View
                                                                                 Cutout dimensions:
                                                                                 192mm [7.559"] W x 138mm [5.433"] H
                                            Rear View
                      a       DIP SW & Reset button             g       Com1 RS485, Com3 RS485, Com3 RS232
                      b       Fuse                              h       Com1 RS232, Com2 RS232
                      c       Power connector                   i       Ethernet port (RJ-45) (MT6070iH N/A)
                      d       VESA 75mm screw holes             j       USB Host port
                      e       Audio (MT6070iH N/A)              k       USB Client port
                      f       SD card slot (MT6070iH N/A)
Downloaded from www.Manualslib.com manuals search engine