0% found this document useful (0 votes)
300 views2 pages

Gu 621 A

Uploaded by

servisergenset
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
300 views2 pages

Gu 621 A

Uploaded by

servisergenset
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
New seneration intelligent Genset controller. When you use it you will EXPEFIENGE the difference!!! GU621A Genset Controller Description: GU621Ais an Automatic Mains (Utility) Failure module which is designed to monitor the mains (utility ) and on failure automaticaly starts the generator and transfers the load, On return of the mains (utility) the controller automatically returns the load to the mains and stops the Generator after a cool down period The module also monitors and protects the engine, indicating operational status, fault conditions and metering on the front panel LCD and LED's +128 x 64 graphic LCD + True RMS measuring * Configuration of parameters by front panel push buttons or communication software + RS485, RS232, of USB port for remote communication + Configurable fuel output energise to stop or energise to run +7 Configurable inputs. +5 Configurable outputs, 2 used for ATS control + 2Analogue inputs configurable for different senders for Oil pressure and Engine temperature: + 2Aux configurable analogue inputs + Push Buttons for manual control of GCRIMCR Warning and Shutdown + Mains phase voltage L1-N L2-N L3-N Alarms: + Mains line volage L1-L2 L2-L3 L3-LA + Lowoil pressure + Mains frequency Hz + High engine temperature + Generator phase voltage LA.N L2-N L3-N + Over! under speed * Generator ine voltage L4-L2 L2-L3 L3-L1 + High’ low gen voltage * Generator current 41213 + High/ low Mains voltage * Generator frequency Hz + Startfailure + Engine speed RPM * Stop failure + Generator phase apparent powerkvA A1AZA3 SA + Emergency stop + Generator phase active power kw Pi P2P3 DP * Charge failure + Generator phase reactive power kvAr Qt Q2.Q3 5Q + Highvlow battery voltage + Generator phase power factor PF PF1 PF2 PFS * Aux shutdown alarm + Generator total active power kwh * Aux Warning + Generatortotal reactive power kvArh + Over current + Battery voltage Vee 1 ; : + Engine running hours counter h ‘Optional Function (on ordering): + Engine tomporature C (F) + Speed contol for DC actuator motor * Oil pressure BAR (PSI) + Operating Temperature -40 to 70°C. + Aux. configurable analogue inputs #1 With GPRS-DTU or Ethemet DTU for remote, + Aux. configurable analogue inputs #2 comunication instead of Rs 485, RS232, of USB port for remote communication, + J1989 CAN bus communication port Specification: + DC supply: 8.0V to 35V continuous + Cranking drop outs: OV for 100mS, assuming DC supply was at least 10V before éropout and recovers to 5V + AC input voltage: phase voltage 15-300 Vac RMS (AC frequency =40 Hz) + AC input frequency: 3-70Hz (voltage= 15V) + Max operating current: @12V 0.48, @24V 0.28 + Max frequency input of the speed sender: 10000Hz + Voltage input of the speed sender: 1-70 Vdc + Accuracy 0.5% + Start relay ouiput: 164/30Vde + Fuel relay output: 16A/30Vde + Aux. control relay output: 3 A/SOVde + Protection:Controller fascia IP65 when correctly installed + Operating temperature: -20 to 70°C + Storage temperature: -30 to 80°C [JTNH| The control spe of dynamic; Outline Dimension Drawing: etext) Product Wi 82mmxH1 44mm WitammxH ‘SG (without connection WOO"TWNOILVNYALNINASUVH

You might also like