Motor Control Equipment Guide

This document provides information about 3-pole contactors for motor control and power switching, including their rated operational power and current for IEC and UL/CSA standards. It also lists main accessories such as auxiliary contact blocks and timers.

Uploaded by

Sami Salman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
270 views78 pages

Motor Control Equipment Guide

This document provides information about 3-pole contactors for motor control and power switching, including their rated operational power and current for IEC and UL/CSA standards. It also lists main accessories such as auxiliary contact blocks and timers.

Uploaded by

Sami Salman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 78

Main catalog

Motor protection and control


Manual motor starters,
A9 ... A300 contactors
and overload relays
Motor rated operational powers and currents

The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz).
These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles.

IEC Motor nominal current: standardized values in blue colour UL / CSA Motor nominal current: standardized values
(according to IEC 60947-4-1 Annex G) (according to IEC 60947-4-1 Annex G and UL 508)
Motor Motor
power 220 V 230 V 240 V 380 V 400 V 415 V 440 V 500 V 660 V 690 V power 208 V 220-240 V 380-415 V 440-480 V 550-600 V
kW A A A A A A A A A A hp A A A A A
0.06 0.37 0.35 0.34 0.21 0.2 0.19 0.18 0.16 0.13 0.12 1/2 2.4 2.2 1.3 1.1 0.9
0.09 0.54 0.52 0.50 0.32 0.3 0.29 0.26 0.24 0.18 0.17 3/4 3.5 3.2 1.8 1.6 1.3
0.12 0.73 0.7 0.67 0.46 0.44 0.42 0.39 0.32 0.24 0.23 1 4.6 4.2 2.3 2.1 1.7
0.18 1 1 1 0.63 0.6 0.58 0.53 0.48 0.37 0.35 1-1/2 6.6 6 3.3 3 2.4
0.25 1.6 1.5 1.4 0.9 0.85 0.82 0.74 0.68 0.51 0.49 2 7.5 6.8 4.3 3.4 2.7
0.37 2.0 1.9 1.8 1.2 1.1 1.1 1 0.88 0.67 0.64 3 10.6 9.6 6.1 4.8 3.9
0.55 2.7 2.6 2.5 1.6 1.5 1.4 1.3 1.2 0.91 0.87 5 16.7 15.2 9.7 7.6 6.1
0.75 3.5 3.3 3.2 2.0 1.9 1.8 1.7 1.5 1.15 1.1 7-1/2 24.2 22 14 11 9
1.1 4.9 4.7 4.5 2.8 2.7 2.6 2.4 2.2 1.7 1.6 10 30.8 28 18 14 11
1.5 6.6 6.3 6 3.8 3.6 3.5 3.2 2.9 2.2 2.1 15 46.2 42 27 21 17
2.2 8.9 8.5 8.1 5.2 4.9 4.7 4.3 3.9 2.9 2.8 20 59.4 54 34 27 22
3 11.8 11.3 10.8 6.8 6.5 6.3 5.7 5.2 4 3.8 25 74.8 68 44 34 27
4 15.7 15 14.4 8.9 8.5 8.2 7.4 6.8 5.1 4.9 30 88 80 51 40 32
5.5 20.9 20 19.2 12.1 11.5 11.1 10.1 9.2 7 6.7 40 114 104 66 52 41
7.5 28.2 27 25.9 16.3 15.5 14.9 13.6 12.4 9.3 8.9 50 143 130 83 65 52
11 39.7 38 36.4 23.2 22 21.2 19.3 17.6 13.4 12.8 60 169 154 103 77 62
15 53.3 51 48.9 30.5 29 28 25.4 23 17.8 17 75 211 192 128 96 77
18.5 63.8 61 58.5 36.8 35 33.7 30.7 28 22 21 100 273 248 165 124 99
22 75.3 72 69 43.2 41 39.5 35.9 33 25.1 24 125 343 312 208 156 125
30 100 96 92 57.9 55 53 48.2 44 33.5 32 150 396 360 240 180 144
37 120 115 110 69 66 64 58 53 40.8 39 200 528 480 320 240 192
45 146 140 134 84 80 77 70 64 49.1 47 250 – 604 403 302 242
55 177 169 162 102 97 93 85 78 59.6 57 300 – 722 482 361 289
75 240 230 220 139 132 127 116 106 81 77 350 – 828 560 414 336
90 291 278 266 168 160 154 140 128 97 93 400 – 954 636 477 382
110 355 340 326 205 195 188 171 156 118 113 450 – 1030 – 515 412
132 418 400 383 242 230 222 202 184 140 134 500 – 1180 786 590 472
160 509 487 467 295 280 270 245 224 169 162
200 637 609 584 368 350 337 307 280 212 203
250 782 748 717 453 430 414 377 344 261 250
315 983 940 901 568 540 520 473 432 327 313
355 1109 1061 1017 642 610 588 535 488 370 354
400 1255 1200 1150 726 690 665 605 552 418 400
500 1545 1478 1416 895 850 819 745 680 515 493
560 1727 1652 1583 1000 950 916 832 760 576 551
630 1928 1844 1767 1116 1060 1022 929 848 643 615
710 2164 2070 1984 1253 1190 1147 1043 952 721 690
800 2446 2340 2243 1417 1346 1297 1179 1076 815 780
900 2760 2640 2530 1598 1518 1463 1330 1214 920 880
1000 3042 2910 2789 1761 1673 1613 1466 1339 1014 970
1SBC101589S0201
Motor protection and control
Manual motor starters, contactors and overload relays

1
Overview

2
Manual motor starters

3
A contactors and N contactor relays

4
Thermal overload relays

5
General technical data

6
Index

You can access to more product details, click on the order code

Connect to
Summary_1

ABB | 1/1
3-pole contactors, for motor control and power switching

IEC (1) AC-3 Rated operational power θ ≤ 55 °C, 400 V kW 4 5.5 7.5 11 15 18.5
UL/CSA 3-phase motor rating 480 V hp 5 7.5 10 20 25 30

AC Control supply Type A9 A12 A16 A26 A30 A40

IEC AC-3 Rated operational current θ ≤ 55 °C , 400 V A 9 12 17 26 32 37


AC-1 Rated operational current θ ≤ 40 °C, 690 V A 25 27 30 45 55 60
UL/CSA General use rating 600 V A 21 25 30 40 50 60
NEMA NEMA Size 00 0 — 1 1P —
(1) 1000 V IEC ratings available for A50 ... A300 contactors.

Main accessories
Auxiliary contact blocks Front mounting CA5-10 (1 x N.O.)
CA5-01 (1 x N.C.)
Side mounting CAL5-11 (1 x N.O. + 1 x N.C.)
Timers Electronic TEF5-ON
TEF5-OFF
TE5S (for star-delta starters - direct timing - separate mounting)
Interlocking units Mechanical VM5-1

Mechanical / Electrical VE5-1


Surge suppressors Varistor (AC/DC) RV5 (24...440 V)
RC Type (AC) RC5-1 (24...440 V)

Overload relays
Thermal relays Class 10A TA25DU-M (0.10…32 A)
(Class 10A or 20 for TA80DU)
(Class 30 for TA450SU)
TA42DU-M (18…42 A)

Manual motor starters


Thermal / magnetic protection MS116 (0.10...32 A) MS450 (28...50 A)
Class 10 lcs up to 50 kA for class 10 A lcs up to 50 kA

MS132 (0.10...32 A)
lcs up to 100 kA

MS497 (22…100 A)
Ics up to 100 kA

Magnetic only types MO132 (0.16...32 A) MO496 (32…100 A)


Ics up to 100 kA Ics up to 100 kA

MO450 (40…50 A)
Ics up to 50 kA

1/2 | ABB
1

22 30 37 45 55 75 90 110 140 160


40 60 60 60 75 100 125 150 200 250

A50 A63 A75 A95 A110 A145 A185 A210 A260 A300

50 65 75 96 110 145 185 210 260 305


100 115 125 145 160 250 275 350 400 500
80 90 105 125 150 230 250 300 350 400
2 — 3 — — 4 — — 5 —

CAL18-11 (1 x N.O. + 1 x N.C.)

VM300H
VM300V
VE5-2

RC5-2 (24...440 V) RC5-3 (250...440 V)

TA75DU-M (18…80 A) TA80DU (29...80 A) TA200DU (66...200 A) TA450DU (130...310 A)


TA110DU (66...110 A) TA450SU (40...310 A)

Short-circuit protection devices


Tmax Circuit breaker and accessories

MS495 (45…100 A)
Ics up to 50 kA
1SBC101875S0201

MO495 (63…100 A)
Ics up to 50 kA

ABB | 1/3
1

N3

1/4 | ABB
4-pole contactors

IEC AC-1 Rated operational current θ ≤ 40 °C, 690 V A 25 30 45 70 100 125


UL/CSA General use rating 600 V A 21 30 40 65 80 105

AC Control supply Type A9 A16 A26 A45 A50 A75

IEC AC-1 Rated operational current θ ≤ 40 °C A 25 30 45 70 100 125


θ ≤ 55 °C A 22 27 40 60 85 105
θ ≤ 70 °C A 18 23 32 50 70 85
With conductor cross sectional area mm 2 2.5 4 6 25 35 50
Rated operational voltage Ue max. V 690 690 690 1000 1000 1000

Main accessories
Auxiliary contact blocks Front mounting CA5-10 (1 x N.O.)
CA5-01 (1 x N.C.)
Side mounting CAL5-11 (1 x N.O. + 1 x N.C.)
Timers Electronic TEF5-ON
TEF5-OFF
TE5S (for star-delta starters - direct timing - separate mounting)
Interlocking units Mechanical VM5-1
Mechanical / Electrical VE5-1 VE5-2
Surge suppressors Varistor (AC / DC) RV5 (24...440 V)
RC Type (AC) RC5-1 (24...440 V) RC5-2 (24...440 V)

1SBC101884S0201

ABB | 1/5
3

Summary_3

3/0 | ABB
A contactors and N contactor relays

A 3-pole contactors
Overview 3/2

4 to 55 kW / 5 to 75 hp
A9 … A16 AC operated 3/4
A26 … A40 AC operated 3/5
A50 ... A75 AC operated 3/6
3
A95 ... A110 AC operated 3/7
Main accessories 3/8

75 to 160 kW / 100 to 250 hp


A145 … A300 AC operated 3/11
Main accessories 3/12

Technical data 3/14


Terminal marking and positioning 3/27
Star-delta starting of three-phase asynchronous motors 3/28

A 4-pole contactors
Overview 3/30

25 to 125 A AC-1
A9 … A16 AC operated 3/31
A26 AC operated 3/32
A45 … A75 AC operated 3/33
Main accessories 3/34
Technical data 3/36
Terminal marking and positionning 3/44

N contactor relays
N AC operated 3/45
Main accessories 3/46
Technical data 3/48
Terminal marking and positioning 3/50

Accessories for A contactors and N contactor relays


Auxiliary contact blocks 3/52
Electronic timers 3/55
Mechanical and electrical interlock units 3/58
Electronic timers for star-delta starters 3/60
Surge suppressors for contactor coils 3/62
Interface relays 3/64
Mechanical latching units 3/66
Function markers - Impulse contact blocks 3/68
Terminal shrouds, terminal enlargements, terminal extensions,
connector terminals 3/69
Summary_3

Voltage code table 3/70

ABB | 3/1
3-pole contactors, for motor control and power switching

3
IEC (1) AC-3 Rated operational power θ ≤ 55 °C, 400 V kW 4 5.5 7.5 11 15 18.5
UL/CSA 3-phase motor rating 480 V hp 5 7.5 10 20 25 30

AC Control supply Type A9 A12 A16 A26 A30 A40

IEC AC-3 Rated operational current θ ≤ 55 °C , 400 V A 9 12 17 26 32 37


AC-1 Rated operational current θ ≤ 40 °C, 690 V A 25 27 30 45 55 60
UL/CSA General use rating 600 V A 21 25 30 40 50 60
NEMA NEMA Size 00 0 — 1 1P —
(1) 1000 V IEC ratings available for A50 ... A300 contactors.

Main accessories
Auxiliary contact blocks Front mounting CA5-10 (1 x N.O.)
CA5-01 (1 x N.C.)
Side mounting CAL5-11 (1 x N.O. + 1 x N.C.)
Timers Electronic TEF5-ON
TEF5-OFF
TE5S (for star-delta starters - direct timing - separate mounting)
Interlocking units Mechanical VM5-1

Mechanical / Electrical VE5-1


Surge suppressors Varistor (AC/DC) RV5 (24...440 V)
RC Type (AC) RC5-1 (24...440 V)

Overload relays
Thermal relays Class 10A TA25DU-M (0.10…32 A)
(Class 10A or 20 for TA80DU)
(Class 30 for TA450SU)
TA42DU-M (18…42 A)

Manual motor starters


Thermal / magnetic protection MS116 (0.10...32 A) MS450 (28...50 A)
Class 10 lcs up to 50 kA for class 10 A lcs up to 50 kA

MS132 (0.10...32 A)
lcs up to 100 kA

MS497 (22…100 A)
Ics up to 100 kA

Magnetic only types MO132 (0.16...32 A) MO496 (32…100 A)


Ics up to 100 kA Ics up to 100 kA

MO450 (40…50 A)
Ics up to 50 kA

1/2 | ABB
3/2
1

3
22 30 37 45 55 75 90 110 140 160
40 60 60 60 75 100 125 150 200 250

A50 A63 A75 A95 A110 A145 A185 A210 A260 A300

50 65 75 96 110 145 185 210 260 305


100 115 125 145 160 250 275 350 400 500
80 90 105 125 150 230 250 300 350 400
2 — 3 — — 4 — — 5 —

CAL18-11 (1 x N.O. + 1 x N.C.)

VM300H
VM300V
VE5-2

RC5-2 (24...440 V) RC5-3 (250...440 V)

TA75DU-M (18…80 A) TA80DU (29...80 A) TA200DU (66...200 A) TA450DU (130...310 A)


TA110DU (66...110 A) TA450SU (40...310 A)

Short-circuit protection devices


Tmax Circuit breaker and accessories

MS495 (45…100 A)
Ics up to 50 kA
1SBC101875S0201.indd
1SBC101875S0201

MO495 (63…100 A)
Ics up to 50 kA

ABB | 3/3
1/3
A9 ... A16 3-pole contactors
4 to 7.5 kW
AC operated
Description
A9 … A16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC or
220 V DC.
1SBC573122F0301

These contactors are of the block type design with:


–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
A9-30-10
3 Ordering details
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational 3-phase General voltage contacts
power current motor use Uc fitted Pkg
θ ≤ 40 °C rating rating (1) (1 pce)
400 V 480 V 600 V AC
AC-3 AC-1
kW A hp A V 50 Hz V 60 Hz kg
4 25 5 21 24 24 1 0 A9-30-10 1SBL141001R8110 0.340
0 1 A9-30-01 1SBL141001R8101 0.340
48 48 1 0 A9-30-10 1SBL141001R8310 0.340
0 1 A9-30-01 1SBL141001R8301 0.340
110 110…120 1 0 A9-30-10 1SBL141001R8410 0.340
0 1 A9-30-01 1SBL141001R8401 0.340
220…230 230…240 1 0 A9-30-10 1SBL141001R8010 0.340
0 1 A9-30-01 1SBL141001R8001 0.340
230…240 240…260 1 0 A9-30-10 1SBL141001R8810 0.340
0 1 A9-30-01 1SBL141001R8801 0.340
380…400 400…415 1 0 A9-30-10 1SBL141001R8510 0.340
0 1 A9-30-01 1SBL141001R8501 0.340
400…415 415…440 1 0 A9-30-10 1SBL141001R8610 0.340
0 1 A9-30-01 1SBL141001R8601 0.340
5.5 27 7.5 25 24 24 1 0 A12-30-10 1SBL161001R8110 0.340
0 1 A12-30-01 1SBL161001R8101 0.340
48 48 1 0 A12-30-10 1SBL161001R8310 0.340
0 1 A12-30-01 1SBL161001R8301 0.340
110 110…120 1 0 A12-30-10 1SBL161001R8410 0.340
0 1 A12-30-01 1SBL161001R8401 0.340
220…230 230…240 1 0 A12-30-10 1SBL161001R8010 0.340
0 1 A12-30-01 1SBL161001R8001 0.340
230…240 240…260 1 0 A12-30-10 1SBL161001R8810 0.340
0 1 A12-30-01 1SBL161001R8801 0.340
380…400 400…415 1 0 A12-30-10 1SBL161001R8510 0.340
0 1 A12-30-01 1SBL161001R8501 0.340
400…415 415…440 1 0 A12-30-10 1SBL161001R8610 0.340
0 1 A12-30-01 1SBL161001R8601 0.340
7.5 30 10 30 24 24 1 0 A16-30-10 1SBL181001R8110 0.340
0 1 A16-30-01 1SBL181001R8101 0.340
48 48 1 0 A16-30-10 1SBL181001R8310 0.340
0 1 A16-30-01 1SBL181001R8301 0.340
110 110…120 1 0 A16-30-10 1SBL181001R8410 0.340
0 1 A16-30-01 1SBL181001R8401 0.340
220…230 230…240 1 0 A16-30-10 1SBL181001R8010 0.340
0 1 A16-30-01 1SBL181001R8001 0.340
230…240 240…260 1 0 A16-30-10 1SBL181001R8810 0.340
0 1 A16-30-01 1SBL181001R8801 0.340
380…400 400…415 1 0 A16-30-10 1SBL181001R8510 0.340
0 1 A16-30-01 1SBL181001R8501 0.340
400…415 415…440 1 0 A16-30-10 1SBL181001R8610 0.340
0 1 A16-30-01 1SBL181001R8601 0.340
(1) Other control voltages see voltage code table.

Main dimensions mm, inches


74 2.91"

68 2.68"
5.5 0.22"
35 mm EN/IEC 60715
74 2.91"

1SBC101855S0201

44 1.73" 4 10
0.16" 0.39"
A9, A12, A16

3/4 | ABB
A26 ... A40 3-pole contactors
11 to 18.5 kW
AC operated
Description
A26 ... A40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC or
220 V DC.
1SBC573092F0301

These contactors are of the block type design with:


–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
A26-30-10
Ordering details 3
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational 3-phase General voltage contacts
power current motor use Uc fitted Pkg
θ ≤ 40 °C rating rating (1) (1 pce)
400 V 480 V 600 V AC
AC-3 AC-1
kW A hp A V 50 Hz V 60 Hz kg
1SBC101355F0014

11 45 20 40 24 24 1 0 A26-30-10 1SBL241001R8110 0.600


0 1 A26-30-01 1SBL241001R8101 0.600
48 48 1 0 A26-30-10 1SBL241001R8310 0.600
0 1 A26-30-01 1SBL241001R8301 0.600
110 110…120 1 0 A26-30-10 1SBL241001R8410 0.600
A40-30-10 0 1 A26-30-01 1SBL241001R8401 0.600
220…230 230…240 1 0 A26-30-10 1SBL241001R8010 0.600
0 1 A26-30-01 1SBL241001R8001 0.600
230…240 240…260 1 0 A26-30-10 1SBL241001R8810 0.600
0 1 A26-30-01 1SBL241001R8801 0.600
380…400 400…415 1 0 A26-30-10 1SBL241001R8510 0.600
0 1 A26-30-01 1SBL241001R8501 0.600
400…415 415…440 1 0 A26-30-10 1SBL241001R8610 0.600
0 1 A26-30-01 1SBL241001R8601 0.600
15 55 25 50 24 24 1 0 A30-30-10 1SBL281001R8110 0.710
0 1 A30-30-01 1SBL281001R8101 0.710
48 48 1 0 A30-30-10 1SBL281001R8310 0.710
0 1 A30-30-01 1SBL281001R8301 0.710
110 110…120 1 0 A30-30-10 1SBL281001R8410 0.710
0 1 A30-30-01 1SBL281001R8401 0.710
220…230 230…240 1 0 A30-30-10 1SBL281001R8010 0.710
0 1 A30-30-01 1SBL281001R8001 0.710
230…240 240…260 1 0 A30-30-10 1SBL281001R8810 0.710
0 1 A30-30-01 1SBL281001R8801 0.710
380…400 400…415 1 0 A30-30-10 1SBL281001R8510 0.710
0 1 A30-30-01 1SBL281001R8501 0.710
400…415 415…440 1 0 A30-30-10 1SBL281001R8610 0.710
0 1 A30-30-01 1SBL281001R8601 0.710
18.5 60 30 60 24 24 1 0 A40-30-10 1SBL321001R8110 0.710
0 1 A40-30-01 1SBL321001R8101 0.710
48 48 1 0 A40-30-10 1SBL321001R8310 0.710
0 1 A40-30-01 1SBL321001R8301 0.710
110 110…120 1 0 A40-30-10 1SBL321001R8410 0.710
0 1 A40-30-01 1SBL321001R8401 0.710
220…230 230…240 1 0 A40-30-10 1SBL321001R8010 0.710
0 1 A40-30-01 1SBL321001R8001 0.710
230…240 240…260 1 0 A40-30-10 1SBL321001R8810 0.710
0 1 A40-30-01 1SBL321001R8801 0.710
380…400 400…415 1 0 A40-30-10 1SBL321001R8510 0.710
0 1 A40-30-01 1SBL321001R8501 0.710
400…415 415…440 1 0 A40-30-10 1SBL321001R8610 0.710
0 1 A40-30-01 1SBL321001R8601 0.710
(1) Other control voltages see voltage code table.

Main dimensions mm, inches


93.6 3.69" 108.3 4.26"

9 0.35" 6.3 0.25" 9 0.35" 6.3 0.25"


35 mm EN/IEC 60715
35 mm EN/IEC 60715
90 3.54"

90 3.54"

1SBC101856S0201

54 2.13" 4 0.16" 10 0.39" 54 2.13" 4 0.16" 10 0.39"

A26 A30, A40

ABB | 3/5
A50 ... A75 3-pole contactors
22 to 37 kW
AC operated
Description
A50 ... A75 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC /
1000 V AC or 220 V DC.
These contactors are of the block type design with:
–– 3 main poles
–– control circuit: AC operated
1SBC101360F0010

–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
3
Ordering details
A50-30-11 IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational 3-phase General voltage contacts
power current motor use Uc fitted Pkg
θ ≤ 40 °C rating rating (1) (1 pce)
400 V 480 V 600 V AC
AC-3 AC-1
kW A hp A V 50 Hz V 60 Hz kg
22 100 40 80 24 24 1 1 A50-30-11 1SBL351001R8111 1.200
48 48 1 1 A50-30-11 1SBL351001R8311 1.200
110 110…220 1 1 A50-30-11 1SBL351001R8411 1.200
220…230 230…240 1 1 A50-30-11 1SBL351001R8011 1.200
230…240 240…260 1 1 A50-30-11 1SBL351001R8811 1.200
380…400 400…415 1 1 A50-30-11 1SBL351001R8511 1.200
400…415 415…440 1 1 A50-30-11 1SBL351001R8611 1.200
30 115 60 90 24 24 1 1 A63-30-11 1SBL371001R8111 1.200
48 48 1 1 A63-30-11 1SBL371001R8311 1.200
110 110…220 1 1 A63-30-11 1SBL371001R8411 1.200
220…230 230…240 1 1 A63-30-11 1SBL371001R8011 1.200
230…240 240…260 1 1 A63-30-11 1SBL371001R8811 1.200
380…400 400…415 1 1 A63-30-11 1SBL371001R8511 1.200
400…415 415…440 1 1 A63-30-11 1SBL371001R8611 1.200
37 125 60 105 24 24 1 1 A75-30-11 1SBL411001R8111 1.200
48 48 1 1 A75-30-11 1SBL411001R8311 1.200
110 110…220 1 1 A75-30-11 1SBL411001R8411 1.200
220…230 230…240 1 1 A75-30-11 1SBL411001R8011 1.200
230…240 240…260 1 1 A75-30-11 1SBL411001R8811 1.200
380…400 400…415 1 1 A75-30-11 1SBL411001R8511 1.200
400…415 415…440 1 1 A75-30-11 1SBL411001R8611 1.200
(1) Other control voltages see voltage code table.

Main dimensions mm, inches


108 4.25"
35 mm x15 EN/IEC 60715

6 0.24" 6.5 0.26"


110 4.33"
74 2.91"

4
0.16"
75 mm EN/IEC 60715

1SBC101364S0201

12 70 2.76" 10 0.39" 10 0.39"


0.47"

A50, A63, A75

3/6 | ABB
A95 … A110 3-pole contactors
45 to 55 kW
AC operated
Description
A95 ... A110 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 / 1000 V AC or 220 V DC.
These contactors are of the block type design with:
- 3 main poles
- control circuit: AC operated
- add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
3
1SBC573242F0301

IEC UL / CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational 3-phase General voltage contacts
power current motor use Uc fitted Pkg
θ ≤ 40 °C rating rating (1) (1 pce)
400 V 480 V 600 V AC
A95-30-11 AC-3 AC-1
kW A hp A V 50 Hz V 60 Hz kg
45 145 60 125 24 24 1 1 A95-30-11 1SFL431001R8111 2.040
48 48 1 1 A95-30-11 1SFL431001R8311 2.040
110 110…120 1 1 A95-30-11 1SFL431001R8411 2.040
220…230 230…240 1 1 A95-30-11 1SFL431001R8011 2.040
230…240 240…260 1 1 A95-30-11 1SFL431001R8811 2.040
380…400 400…415 1 1 A95-30-11 1SFL431001R8511 2.040
400…415 415…440 1 1 A95-30-11 1SFL431001R8611 2.040
55 160 75 140 24 24 1 1 A110-30-11 1SFL451001R8111 2.040
48 48 1 1 A110-30-11 1SFL451001R8311 2.040
110 110…120 1 1 A110-30-11 1SFL451001R8411 2.040
220…230 230…240 1 1 A110-30-11 1SFL451001R8011 2.040
230…240 240…260 1 1 A110-30-11 1SFL451001R8811 2.040
380…400 400…415 1 1 A110-30-11 1SFL451001R8511 2.040
400…415 415…440 1 1 A110-30-11 1SFL451001R8611 2.040
(1) Other control voltages see voltage code table.

Main dimensions mm, inches


123.5 4.86"
6.5 0.26"

6 0.24"
148 5.83"
74 2.91"

1SFC101146C0201
E0788D1
E0787D

12 0.47" 10 0.39" 20
90 3.54"
0.79"

A95, A110

ABB | 3/7
A9 … A110 3-pole contactors
Main accessories

Contactor and main accessories (other accessories available)

RV5, RC5
Surge suppressor

3
A contactor

VE5
Interlock unit A2
A1

TEF5
Electronic timer

BX4-CA
Protective cover

CAL
2-pole auxiliary CA5
contact block 4-pole auxiliary
contact block

CA5
1-pole auxiliary
contact block

TA
Thermal overload relay

Main accessory fitting details


Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor Main Built-in Front-mounted accessories Side-mounted accessories
types poles auxiliary Auxiliary contact blocks Electronic timer Auxiliary contact blocks Interlock unit
contacts

1-pole CA5 4-pole CA5 TEF5 2-pole CAL VM5 or VE5


A9 ... A26 3 0 1 0 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 or 1 x VM5-1 or VE5-1
3 0 0 1 (1) +1 x CAL5-11
A30, A40 3 0 1 0 1 to 5 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 or 1 x VM5-1 or VE5-1
3 0 0 1 (1) + 1 x 1-pole CA5 + 1 x CA5 (1-pole) +1 x CAL5-11
A50 ... A75 3 0 1 1 1 to 6 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 x CAL5-11 or 1 x VE5-2
+ 2 x 1-pole CA5 + 2 x CA5 (1-pole)
A95, A110 3 0 1 1 1 to 6 x CA5 or 1 x CA5 (4-pole) – + 1 x CAL18-11 or 1 x VE5-2
+ 2 x 1-pole CA5

(1) 2 N.C. CA5 auxiliary contacts maximum in mounting position 5.

Overload relays fitting details (2)


Contactor types Thermal overload relays
A9 ... A26 TA25DU-M (0.1...0.32 A)
A30, A40 TA25DU-M (0.1...0.32 A) or TA42DU-M (18...42 A)
A50 … A75 TA75DU-M (18...80 A)
A95, A110 TA80DU (29...80 A) or TA110DU (65...110 A)
1SBC101871S0201

The addition of a thermal overload relay on the contactor does not prevent fitting of many other accessories as shown above.
(2) Direct mounting - No kit required.

3/8 | ABB
A9 … A110 3-pole contactors
Main accessories

Ordering details (1)


1SBC580992F0301

For contactors Auxiliary Type Order code Pkg Weight


contacts qty (1 pce)

CA5-10 kg

Front-mounted instantaneous auxiliary contact blocks


A9 ... A110 1 – CA5-10 1SBN010010R1010 10 0.014
3
1SBC573752F0301

– 1 CA5-01 1SBN010010R1001 10 0.014


A9-30-10 ... A40-30-10 2 2 CA5-22M 1SBN010040R1122 2 0.060
A9-30-01 ... A40-30-01 2 2 CA5-22U 1SBN010040R1322 2 0.060
A50 ... A110 2 2 CA5-22E 1SBN010040R1022 2 0.060
CAL5-11 Side-mounted instantaneous auxiliary contact block
A9 … A75 1 1 CAL5-11 1SBN010020R1011 2 0.050
A95, A110 1 1 CAL18-11 1SFN010720R1011 2 0.050
1SBC572822F0301

Interlock units
A9 ... A40 Mechanical – – VM5-1 1SBN030100R1000 1 0.066
Mechanical and electrical – 2 VE5-1 1SBN030110R1000 1 0.076
A50 ... A110 Mechanical and electrical – 2 VE5-2 1SBN030210R1000 1 0.146
VE5-1

01 01 For contactors Time delay Delay Auxiliary Type Order code Pkg Weight
NC NC range type contacts qty (1 pce)
selected by
switch
02 02 kg

VE5-1, VE5-2 Electronic timers


Terminal marking and positioning A9 ... A75 0.1...1 s ON-delay 1 1 TEF5-ON 1SBN020312R1000 1 0.065
1...10 s
10...100 s OFF-delay 1 1 TEF5-OFF 1SBN020314R1000 1 0.065

Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.

For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V AC DC kg
1SBC101396F0014

Surge suppressors
A9 ... A110 24...50 ● ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● ● RV5/250 1SBN050010R1002 2 0.015
250...440 ● ● RV5/440 1SBN050010R1003 2 0.015
TEF5-OFF A9 ... A40 24...50 ● – RC5-1/50 1SBN050100R1000 2 0.012
50...133 ● – RC5-1/133 1SBN050100R1001 2 0.012
110...250 ● – RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● – RC5-1/440 1SBN050100R1003 2 0.012
A50 … A110 24...50 ● – RC5-2/50 1SBN050200R1000 2 0.015
50...133 ● – RC5-2/133 1SBN050200R1001 2 0.015
110...250 ● – RC5-2/250 1SBN050200R1002 2 0.015
1SBC574001F0301

250...440 ● – RC5-2/440 1SBN050200R1003 2 0.015


(1) See "Main accessory fitting details" table.

RV5/50
1SBC101872S0201

ABB | 3/9
3

N1

3/10 | ABB
A145 ... A300 3-pole contactors
75 to 160 kW
AC operated
Description
A145 ... A300 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 / 1000 V AC (2) or 220 V DC.
These contactors are of the block type design with:
–– 3 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details 3
1SFC101029F0201

IEC UL / CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational 3-phase General voltage contacts
power current motor use Uc fitted Pkg
θ ≤ 40 °C rating rating (1) (1 pce)
400 V 690 V 480 V 600 V AC
A185-30-11 AC-3 AC-1
kW A hp A V 50 Hz V 60 Hz kg
75 250 100 230 24 24 1 1 A145-30-11 1SFL471001R8111 3.500
48 48 1 1 A145-30-11 1SFL471001R8311 3.500
110 110…120 1 1 A145-30-11 1SFL471001R8411 3.500
220…230 230…240 1 1 A145-30-11 1SFL471001R8011 3.500
230…240 240…260 1 1 A145-30-11 1SFL471001R8811 3.500
380…400 400…415 1 1 A145-30-11 1SFL471001R8511 3.500
400…415 415…440 1 1 A145-30-11 1SFL471001R8611 3.500
90 275 125 250 24 24 1 1 A185-30-11 1SFL491001R8111 3.500
48 48 1 1 A185-30-11 1SFL491001R8311 3.500
110 110…120 1 1 A185-30-11 1SFL491001R8411 3.500
220…230 230…240 1 1 A185-30-11 1SFL491001R8011 3.500
230…240 240…260 1 1 A185-30-11 1SFL491001R8811 3.500
380…400 400…415 1 1 A185-30-11 1SFL491001R8511 3.500
400…415 415…440 1 1 A185-30-11 1SFL491001R8611 3.500
1SFC101030F0201

110 350 150 300 24 24 1 1 A210-30-11 1SFL511001R8111 6.100


48 48 1 1 A210-30-11 1SFL511001R8311 6.100
110 110…120 1 1 A210-30-11 1SFL511001R8411 6.100
220…230 230…240 1 1 A210-30-11 1SFL511001R8011 6.100
230…240 240…260 1 1 A210-30-11 1SFL511001R8811 6.100
A300-30-11 380…400 400…415 1 1 A210-30-11 1SFL511001R8511 6.100
400…415 415…440 1 1 A210-30-11 1SFL511001R8611 6.100
140 400 200 350 24 24 1 1 A260-30-11 1SFL531001R8111 6.100
48 48 1 1 A260-30-11 1SFL531001R8311 6.100
110 110…120 1 1 A260-30-11 1SFL531001R8411 6.100
220…230 230…240 1 1 A260-30-11 1SFL531001R8011 6.100
230…240 240…260 1 1 A260-30-11 1SFL531001R8811 6.100
380…400 400…415 1 1 A260-30-11 1SFL531001R8511 6.100
400…415 415…440 1 1 A260-30-11 1SFL531001R8611 6.100
160 500 250 400 24 24 1 1 A300-30-11 1SFL551001R8111 6.100
48 48 1 1 A300-30-11 1SFL551001R8311 6.100
110 110…120 1 1 A300-30-11 1SFL551001R8411 6.100
220…230 230…240 1 1 A300-30-11 1SFL551001R8011 6.100
230…240 240…260 1 1 A300-30-11 1SFL551001R8811 6.100
380…400 400…415 1 1 A300-30-11 1SFL551001R8511 6.100
400…415 415…440 1 1 A300-30-11 1SFL551001R8611 6.100
(1) Other control voltages see voltage code table.
(2) 690 V AC for A210 ... A300, 1000 V AC for A145, A185.

Main dimensions mm, inches


12 0.47" 140 5.51" 180.5 7.11"

19.5 0.77" 10.2 0.4" 35.5 5


12 0.47" 111.5 4.39"
14 0.55"

1.4" 0.2"
105 4.13" 160 6.3"

17.5 0.69" ø 8.5 0.33" 35.5 1.4" 5 0.2"


10 0.39"

225 8.86"

227 8.94"
187 7.36"

196 7.72"

1SFC101147C0201
E2017D
E2002D

E2016D
E2001D

35 1.38" 43.75 1.72"

A145, A185 A210, A260, A300

ABB | 3/11
A145 ... A300 3-pole contactors
Main accessories

Main accessories (other accessories available)

LW
Terminal
enlargement

3
CAL18-11
LZ 2-pole auxiliary
Connector contact block
terminal

LT
Terminal
shroud

A contactor

VM
Mechanical
interlock CAL18-11B
2-pole auxiliary
contact block
TA
Thermal overload relay

Main accessory fitting details


Contactor Main Available Side-mounted accessories
types poles auxiliary Add-on auxiliary contact blocks Mechanical Mounting and positioning
contacts
interlock units
Factory mounted auxiliary contacts

Add-on CAL18-11 auxiliary contacts

CAL18-11, CAL18-11B Add-on CAL18-11B auxiliary contacts

Contactors + auxiliary contact blocks

A145 ... A300 3 0 1 1 1 x CAL18-11 + 2 x CAL18-11B – B B

Contactors with mechanical interlocking + auxiliary contact blocks

A145 ... A185 3 0 1 1 2 x CAL18-11 (1) + 3 x CAL18-11B (1) + VM...H (2) B B B

A210 ... A300 3 0 1 1 2 x CAL18-11 (1) + 4 x CAL18-11B (1) + VM...H (2) B BB B

(1) Total number of auxiliary contact blocks for the two contactors.
(2) Interlock type, according to the contactor ratings (see "Accessories").

Overload relays fitting details


Contactor types Thermal overload relays
A145, A185 TA200DU (66...200 A) (3)
A210, A300 TA450DU (130...310 A) (3) or TA450SU (40...310 A) (4)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
1SFC101148C0201

(3) Direct mounting - No kit required.


(4) Mounting kit required.

3/12 | ABB
A145 ... A300 3-pole contactors
Main accessories

Ordering details (1)


For contactors Auxiliary Type Order code Pkg Weight
contacts qty (1 pce)
1SFC101033F0201

kg

Side-mounted instantaneous auxiliary contact blocks


CAL18-11
A145 ... A300 1 1 CAL18-11 1SFN010720R1011 2 0.050
1 1 CAL18-11B 1SFN010720R3311 2 0.050 3
Mechanical interlock unit for two horizontal mounted contactors
1SBC580411F0301

A145 ... A300 VM300H 1SFN034700R1000 1 0.150

Terminal shrouds
A145 ... A185 with connectors LT185-AC 1SFN124701R1000 2 0.050
VM300H A145 ... A185 with lugs LT185-AL 1SFN124703R1000 2 0.220
A145 ... A185 with short. bar LY185 LT185-AY 1SFN124704R1000 1 0.050
or between A145 and TA200DU
1SFT98099-019C3

or between A185 and TA200DU


1SFT9099-125

A210 ... A300 with connectors LT300-AC 1SFN125101R1000 2 0.070


A210 ... A300 with lugs LT300-AL 1SFN125103R1000 2 0.280
A210 ... A300 with short bar LY300 LT300-AY 1SFN125104R1000 1 0.075
LT...AC
LT...AL
1SFT98000-014

For contactors Dimensions Type Order code Pkg Weight


hole Ø bar qty (1 pce)
mm mm kg
LT...AY
Terminal enlargements
A145, A185 10.5 20 x 5 LW185 1SFN074707R1000 1 0.250
1SFT98000-011C3

A210 ... A300 10.5 25 x 5 LW300 1SFN075107R1000 1 0.450

Terminal extension
A145, A185 8.5 20 x 5 LX185 1SFN074710R1000 1 0.250
LW A210 ... A300 10.5 20 x 5 LX300 1SFN075110R1000 1 0.350
1SFT98000-012C3

Cables For contactors Cable cross section Type Order code Pkg Weight
LX qty (1 pce)
mm² kg
1SFT98099-011C1

Connector terminals
1SBC580542F0302

Single Cu A145, A185 6...185 – 1SDA023354R0001 3 0.200


A210 ... A300 16...240 – 1SDA023368R0001 3 0.400
LZ Single Al & Cu A145, A185 35...95 – 1SDA023356R0001 3 0.100
A145, A185 25...150 – 1SDA023357R0001 3 0.100
1SFT98099-095C2

LZ A210 ... A300 120...240 – 1SDA023370R0001 3 0.200


Double Cu A145, A185 2 x (50...120) LZ185-2C/120 1SFN074709R1000 3 0.300
Double Al & Cu A210 ... A300 2 x (95...120) – 1SDA025766R0001 3 0.400
(1) For each contactor type, refer to "Main accessory fitting details" table.
LZ

For contactors Rated control circuit Type Order code Pkg Weight
voltage qty
Uc (1 pce)
V AC kg
A145 ... A300 250...440 RC5-3/440 1SFN050300R1003 2 0.028
1SFC101149C0201

ABB | 3/13
A9 ... A30 3-pole contactors
Technical data

Main pole - Utilization characteristics according to IEC


Contactor types AC operated A9 A12 A16 A26 A30
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
Rated operational voltage Ue max. 690 V
Rated frequency (without derating) 50 / 60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 26 A 28 A 30 A 45 A 65 A
With conductor cross-sectional area 4 mm² 4 mm² 4 mm² 6 mm² 16 mm²
3 AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C 25 A 27 A 30 A 45 A 55 A
Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C 22 A 25 A 27 A 40 A 55 A
θ ≤ 70 °C 18 A 20 A 23 A 32 A 39 A
With conductor cross-sectional area 2.5 mm² 4 mm² 4 mm² 6 mm² 10 mm²
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V 9 A 12 A 17 A 26 A 33 A
380-400 V 9 A 12 A 17 A 26 A 32 A
M 415 V 9 A 12 A 17 A 26 A 32 A
3-phase motors
3 440 V 9 A 12 A 16 A 26 A 32 A
500 V 9 A 12 A 14 A 22 A 28 A
690 V 7 A 9A 10 A 17 A 21 A
Rated operational power AC-3 (1)
220-230-240 V 2.2 kW 3 kW 4 kW 6.5 kW 9 kW
380-400 V 4 kW 5.5 kW 7.5 kW 11 kW 15 kW
1500 r.p.m. 50 Hz 415 V 4 kW 5.5 kW 9 kW 11 kW 15 kW
M 1800 r.p.m. 60 Hz
3 3-phase motors 440 V 4 kW 5.5 kW 9 kW 15 kW 18.5 kW
500 V 5.5 kW 7.5 kW 9 kW 15 kW 18.5 kW
690 V 5.5 kW 7.5 kW 9 kW 15 kW 18.5 kW
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1
Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a 12 A 16 A 22 A 30 A 40 A
Rated operational power AC-8a 5.5 kW 7.5 kW 11 kW 15 kW 20 kW
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse 25 A 32 A 32 A 50 A 63 A
Rated short-time withstand current Icw 1s 250 A 280 A 300 A 400 A 600 A
at 40 °C ambient temperature, 10 s 100 A 120 A 140 A 210 A 400 A
in free air from a cold state 30 s 60 A 70 A 80 A 110 A 225 A
1 min 50 A 55 A 60 A 90 A 150 A
15 min 26 A 28 A 30 A 45 A 65 A
Maximum breaking capacity
cos φ = 0.45 at 440 V 250 A 420 A 820 A
at 690 V 90 A 170 A 340 A
Power dissipation per pole Ie / AC-1 0.8 W 1W 1.2 W 1.8 W 2.5 W
Ie / AC-3 0.1 W 0.2 W 0.35 W 0.6 W 0.9 W
Max. electrical switching frequency AC-1 600 cycle/h
AC-3 1200 cycle/h
AC-2, AC-4 300 cycle/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101859S0201

3/14 | ABB
A40 ... A110 3-pole contactors
Technical data

Main pole - Utilization characteristics according to IEC


Contactor types AC operated A40 A50 A63 A75 A95 A110
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
Rated operational voltage Ue max. 690 V 1000 V
Rated frequency (without derating) 50/60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 65 A 100 A 125 A 125 A 145 A 160 A
With conductor cross-sectional area 16 mm² 35 mm² 50 mm² 50 mm² 50 mm² 70 mm²
AC-1 Utilization category
3
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C 60 A 100 A 115 A 125 A 145 A 160 A
Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C 60 A 85 A 95 A 105 A 135 A 145 A
θ ≤ 70 °C 42 A 70 A 80 A 85 A 115 A 130 A
With conductor cross-sectional area 16 mm² 35 mm² 50 mm² 50 mm² 50 mm² 70 mm²
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V 40 A 53 A 65 A 75 A 96 A 110 A
380-400 V 37 A 50 A 65 A 75 A 96 A 110 A
415 V 37 A 50 A 65 A 75 A 96 A 110 A
M 3-phase motors 440 V 37 A 45 A 65 A 70 A 93 A 100 A
3 500 V 33 A 45 A 55 A 65 A 80 A 100 A
690 V 25 A 35 A 43 A 46 A 65 A 82 A
1000 V – 23 A 25 A 28 A 30 A 30 A
Rated operational power AC-3 (1)
220-230-240 V 11 kW 15 kW 18.5 kW 22 kW 25 kW 30 kW
380-400 V 18.5 kW 22 kW 30 kW 37 kW 45 kW 55 kW
1500 r.p.m. 50 Hz 415 V 18.5 kW 25 kW 37 kW 40 kW 55 kW 59 kW
M 1800 r.p.m. 60 Hz 440 V 22 kW 25 kW 37 kW 40 kW 55 kW 59 kW
3 3-phase motors
500 V 22 kW 30 kW 37 kW 45 kW 55 kW 59 kW
690 V 22 kW 30 kW 37 kW 40 kW 55 kW 75 kW
1000 V – 30 kW 33 kW 37 kW 40 kW 40 kW
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1
Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a 50 A 63 A 85 A 95 A 120 A 140 A
Rated operational power AC-8a 22 kW 30 kW 45 kW 45 kW 55 kW 75 kW
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse 63 A 100 A 125 A 160 A 160 A 200 A
Rated short-time withstand current Icw 1s 600 A 1000 A 1320 A
at 40 °C ambient temperature, 10 s 400 A 650 A 800 A
in free air from a cold state 30 s 225 A 370 A 500 A
1 min 150 A 250 A 350 A
15 min 65 A 110 A 135 A 135 A 160 A 175 A
Maximum breaking capacity
cos φ = 0.45 at 440 V 820 A 1300 A 1160 A
at 690 V 340 A 630 A 800 A
Power dissipation per pole Ie / AC-1 3W 5W 6.5 W 7W 6.5 W 7.5 W
Ie / AC-3 1.3 W 1.3 W 1.5 W 2W 2.7 W 3.6 W
Max. electrical switching frequency AC-1 600 cycles/h 300 cycles/h
AC-3 1200 cycles/h 600 cycles/h 300 cycles/h
AC-2, AC-4 300 cycles/h 150 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101876S0201

ABB | 3/15
A145 … A300 3-pole contactors
Technical data

Main pole - Utilization characteristics according to IEC


Contactor types AC operated A145 A185 A210 A260 A300
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
Rated operational voltage Ue max. 1000 V 690 V
Rated frequency (without derating) 50/60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 250 A 275 A 350 A 400 A 500 A (4)
With conductor cross-sectional area (3) 120 mm² 150 mm² 185 mm² 240 mm² 300 mm² (4)
3 AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C 250 A 275 A 350 A 400 A 500 A (4)
Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C 230 A 250 A 300 A 350 A 400 A (4)
θ ≤ 70 °C 180 A 180 A 240 A 290 A 325 A (4)
Ie / Rated operational current AC-1 θ ≤ 40 °C 180 A 200 A – – –
Ue max. ≤ 1000 V, 50/60 Hz θ ≤ 55 °C 180 A 200 A – – –
θ ≤ 70 °C 180 A 180 A – – –
With conductor cross-sectional area 120 mm² 150 mm² 185 mm² 240 mm² 300 mm² (4)
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V 145 A 185 A 210 A 260 A 305 A
380-400 V 145 A 185 A 210 A 260 A 305 A
415 V 145 A 185 A 210 A 260 A 300 A
M 3-phase motors 440 V 145 A 185 A 210 A 240 A 280 A
3 500 V 145 A 170 A 210 A 240 A 280 A
690 V 120 A 170 A 210 A 220 A 280 A
1000 V 80 A 95 A – – –
Rated operational power AC-3 (1)
220-230-240 V 45 kW 55 kW 59 kW 80 kW 90 kW
380-400 V 75 kW 90 kW 110 kW 140 kW 160 kW
1500 r.p.m. 50 Hz 415 V 75 kW 90 kW 110 kW 140 kW 160 kW
M 1800 r.p.m. 60 Hz 440 V 75 kW 90 kW 110 kW 140 kW 160 kW
3 3-phase motors 500 V 90 kW 110 kW 132 kW 180 kW 200 kW
690 V 110 kW 132 kW 160 kW 200 kW 250 kW
1000 V 110 kW 132 kW – – –
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1
Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse 315 A 355 A 400 A 500 A 500 A
Rated short-time withstand current Icw 1 s 1800 A 2000 A 2500 A 3500 A 3500 A
at 40 °C ambient temperature, 10 s 1200 A 1500 A 1700 A 2400 A 2400 A
in free air from a cold state 30 s 800 A 1000 A 1200 A 1500 A 1500 A
1 min 600 A 800 A 1000 A 1100 A 1100 A
15 min 280 A 320 A 400 A 500 A 500 A
Maximum breaking capacity
cos φ = 0.45 at 440 V 1500 A 2000 A 2300 A 2600 A 3000 A
(cos φ = 0.35 for Ie > 100 A) at 690 V 1200 A 1600 A 2000 A 2400 A 2500 A
Power dissipation per pole Ie / AC-1 13 W 16 W 18 W 25 W 32 W
Ie / AC-3 5 W 8W 9W 14 W 18 W
Max. electrical switching frequency AC-1 300 cycles/h 300 cycles/h
AC-3 300 cycles/h 300 cycles/h
AC-2, AC-4 150 cycles/h 150 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see “Coordination with short-circuit protection devices”.
(3) Conductors with preparation.
(4) Use terminal extension / enlargement pieces (LX 300 / LW 300).
1SFC101150C0201

3/16 | ABB
A9 ... A30 3-pole contactors
Technical data

Main pole - Utilization characteristics according to UL / NEMA / CSA


Contactor types AC operated A9 A12 A16 A26 A30
Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V
NEMA size 00 0 – 1 1P
NEMA continuous amp rating Thermal current 9 A 18 A – 27 A 36 A
NEMA maximum horse power ratings
1-phase, 60 Hz 115 V AC 1/3 hp 1 hp – 2 hp 3 hp

NEMA maximum horse power ratings


230 V AC 1 hp 2 hp – 3 hp 5 hp
3
3-phase, 60 Hz 200 V AC 1-1/2 hp 3 hp – 7-1/2 hp –
230 V AC 1-1/2 hp 3 hp – 7-1/2 hp –
460 V AC 1-1/2 hp 5 hp – 10 hp –
575 V AC 2 hp 5 hp – 10 hp –
UL / CSA general use rating
600 V AC 21 A 25 A 30 A 40 A 50 A
With conductor cross-sectional area AWG 10 AWG 8
UL / CSA maximum 1-phase motor rating
Full load current 120 V AC 9.8 A 13.8 A 16 A 28 A 34 A
240 V AC 12 A 12 A 17 A 24 A 40 A
Horse power rating 120 V AC 1/2 hp 3/4 hp 1 hp 2 hp 3 hp
240 V AC 2 hp 2 hp 3 hp 5 hp 7.5 hp
UL / CSA maximum 3-phase motor rating
Full load current (1) 200-208 V AC 7.8 A 11 A 17.5 A 25.3 A 32.2 A
220-240 V AC 6.8 A 9.6 A 15.2 A 28 A 28 A
440-480 V AC 7.6 A 11 A 14 A 27 A 34 A
550-600 V AC 9A 11 A 17 A 27 A 32 A
Horse power rating (1) 200-208 V AC 2 hp 3 hp 5 hp 7.5 hp 10 hp
220-240 V AC 2 hp 3 hp 5 hp 10 hp 10 hp
440-480 V AC 5 hp 7.5 hp 10 hp 20 hp 25 hp
550-600 V AC 7.5 hp 10 hp 15 hp 25 hp 30 hp
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating 35 A 35 A 60 A 90 A 150 A
Fuse type, 600 V FRS-R
Max. electrical switching frequency
For general use 600 cycles/h
For motor use 1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".

General technical data


Contactor types AC operated A9 A12 A16 A26 A30
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature close to contactor
Operation Fitted with thermal overload relay -25...+55 °C
Without thermal overload relay -40...+70 °C
Storage -60...+80 °C
Climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles 10 millions operating cycles
Max. switching frequency 3600 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1 Shock direction 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
A 20 g
A A B1 B2 B1 10 g closed position / 5 g open position
B2 15 g
C1 20 g
C2 C2 20 g
1SBC101860S0201

ABB | 3/17
A40 ... A110 3-pole contactors
Technical data

Main pole - Utilization characteristics according to UL / NEMA / CSA


Contactor types AC operated A40 A50 A63 A75 A95 A110
Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V
NEMA size – 2 – 3 – –
NEMA continuous amp rating Thermal current – 45 A – 90 A – –
NEMA maximum horse power ratings
1-phase, 60 Hz 115 V AC – 3 hp – – – –
3 NEMA maximum horse power ratings
230 V AC – 7-1/2 – – – –

3-phase, 60 Hz 200 V AC – 10 hp – 25 hp – –
230 V AC – 15 hp – 30 hp – –
460 V AC – 25 hp – 50 hp – –
575 V AC – 25 hp – 50 hp – –
UL / CSA general use rating
600 V AC 60 A 80 A 90 A 105 A 125 A 150 A
With conductor cross-sectional area AWG 6 AWG 4 AWG 3 AWG 2 AWG 1 AWG 1/0
UL / CSA maximum 1-phase motor rating
Full load current 120 V AC 34 A 34 A 56 A 80 A 80 A 100 A
240 V AC 40 A 40 A 50 A 68 A 88 A 110 A
Horse power rating 120 V AC 3 hp 3 hp 5 hp 7.5 hp 7.5 hp 10 hp
240 V AC 7.5 hp 7.5 hp 10 hp 15 hp 20 hp 25 hp
UL / CSA maximum 3-phase motor rating
Full load current (1) 200-208 V AC 32.2 A 48.3 A 62.1 A 78.2 A 92 A 92 A
220-240 V AC 42 A 54 A 68 A 80 A 80 A 104 A
440-480 V AC 40 A 52 A 77 A 77 A 77 A 96 A
550-600 V AC 41 A 52 A 77 A 77 A 77 A 99 A
Horse power rating (1) 200-208 V AC 10 hp 15 hp 20 hp 25 hp 30 hp 30 hp
220-240 V AC 15 hp 20 hp 25 hp 30 hp 30 hp 40 hp
440-480 V AC 30 hp 40 hp 60 hp 60 hp 60 hp 75 hp
550-600 V AC 40 hp 50 hp 75 hp 75 hp 75 hp 100 hp
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating 150 A 175 A 200 A 200 A 200 A 200 A
Fuse type, 600 V FRS-R J
Max. electrical switching frequency
For general use 600 cycles/h 300 cycles/h
For motor use 1200 cycles/h 600 cycles/h 300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".

General technical data


Contactor types AC operated A40 A50 A63 A75 A95 A110
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature close to contactor
Operation Fitted with thermal overload relay -25...+55 °C
Without thermal overload relay -40…+70 °C
Storage -60...+80 °C -40...+70 °C
Climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 acc. to IEC 60068-2-30
UTE C 63-100 specification II
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles 10 millions operating cycles
Max. switching frequency 3600 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1 Shock direction 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position (2)
A 20 g
A A B1 B2 B1 10 g closed position / 5 g open position
B2 15 g
C1 20 g
C2 C2 20 g
1SBC101877S0201

(2) These values are not valid for rail mounting with contactors A95 ... A110.

3/18 | ABB
A145 … A300 3-pole contactors
Technical data

Main pole - Utilization characteristics according to UL / NEMA / CSA


Contactor types AC operated A145 A185 A210 A260 A300
Standards UL 508, CSA C22.2 N°14
Maximum operational voltage 600 V
NEMA size 4 – – 5 –
NEMA maximum horse power ratings
1-phase, 60 Hz 115 V AC – – – – –
230 V AC – – – – –
NEMA maximum horse power ratings 3
3-phase, 60 Hz 200 V AC 40 hp 75 hp
230 V AC 50 hp 100 hp
460 V AC 100 hp 200 hp
575 V AC 200 hp 200 hp
UL / CSA general use rating
600 V AC 230 A 250 A 300 A 350 A 400 A
UL / CSA maximum 1-phase motor rating
Full load current 240 V AC – – – – –
Horse power rating 240 V AC – – – – –
UL / CSA maximum 3-phase motor rating
Full load current (1) 200-208 V AC 119.6 A 149.5 A 166.8 A 220.8 A 285.2 A
220-240 V AC 130 A 145 A 192 A 248 A 248 A
440-480 V AC 124 A 156 A 180 A 240 A 302 A
550-600 V AC 125 A 144 A 192 A 242 A 289 A
Horse power rating (1) 200-208 V AC 40 hp 50 hp 60 hp 75 hp 100 hp
220-240 V AC 50 hp 60 hp 75 hp 100 hp 100 hp
440-480 V AC 100 hp 125 hp 150 hp 200 hp 250 hp
550-600 V AC 125 hp 150 hp 200 hp 250 hp 300 hp
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating 300 A 400 A 800 A 800 A 800 A
Fuse type, 600 V J/K5
Maximum electrical switching frequency
For general use 300 cycles/h
For motor use 300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.

General technical data


Contactor types AC operated A145 A185 A210 A260 A300
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature close to contactor
Operation Fitted with thermal overload relay -25 to +55 °C
Storage -40 to +70 °C
Climatic withstand acc. to IEC 60068-2-30
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles 5 millions operating cycles
Max. switching frequency 3600 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
Shock direction 1/2 sinusoidal shock for 30 ms: no change in contact position, closed or open position
A 5g
A
ABB
A B1 B2 B1 5g
B2 5g
C1 5g
C2
C2 5g
1SFC101151C0201

ABB | 3/19
A9 ... A30 3-pole contactors
Technical data

Magnet system characteristics


Contactor types AC operated A9 A12 A16 A26 A30
Coil operating limits AC supply at θ ≤ 55 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage 50/60 Hz
Rated control circuit voltage Uc at 50 Hz 24...690 V
at 60 Hz 24...690 V
Coil consumption Average pull-in value 50 Hz 70 VA 120 VA
3 60 Hz 80 VA 140 VA
50/60 Hz (1) 74 VA / 70 VA 125 VA / 120 VA
Average holding value 50 Hz 8 VA / 2 W 12 VA / 3 W
60 Hz 8 VA / 2 W 12 VA / 3 W
50/60 Hz (1) 8 VA / 2 W 12 VA / 3 W
Drop-out voltage approx. 40...65 % of Uc
Operating time
Between coil energization and: N.O. contact closing 10...26 ms 8...21 ms
N.C. contact opening 7...21 ms 6...18 ms
Between coil de-energization and: N.O. contact opening 4...11 ms 4...11 ms
N.C. contact closing 9...16 ms 7...14 ms
(1) 50/60 Hz coils: see "Coil voltage code table".

Mounting characteristics and conditions for use


Contactor types AC operated A9 A12 A16 A26 A30
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for 3-pole contactor A9 ... A30
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc
positions at θ ≤ 70 °C Uc
6 at θ ≤ 55 °C 0.95…1.1 x Uc
at θ ≤ 70 °C Unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
By screws (not supplied) 2 x M4 screws placed diagonally
1SBC101861S0201

3/20 | ABB
A40 ... A110 3-pole contactors
Technical data

Magnet system characteristics


Contactor types AC operated A40 A50 A63 A75 A95 A110
Coil operating limits AC supply At θ ≤ 55 °C 0.85...1.1 x Uc at θ ≤ 70 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage 50/60 Hz
Rated control circuit voltage Uc at 50 Hz 24…690 V
at 60 Hz 24…690 V
Coil consumption Average pull-in value 50 Hz 120 VA 180 VA 350 VA
60 Hz 140 VA 210 VA 450 VA
3
50/60 Hz (1) 125 VA / 120 VA 190 VA / 180 VA 410 VA / 365 VA
Average holding value 50 Hz 12 VA / 3 W 18 VA / 5.5 W 22 VA / 6.5 W
60 Hz 12 VA / 3 W 18 VA / 5.5 W 26 VA / 8 W
50/60 Hz (1) 12 VA / 3 W 18 VA / 5.5 W 27 VA / 7.5 W
Drop-out voltage Approx. 40...65 % of Uc
Operating time
Between coil energization and: N.O. contact closing 8…21 ms 8…27 ms 10…25 ms
N.C. contact opening 6…18 ms 7…22 ms 7…22 ms
Between coil de-energization and: N.O. contact opening 4…11 ms 4…11 ms 7…15 ms
N.C. contact closing 7…14 ms 7…14 ms 10…18 ms
(1) 50/60 Hz coils: see "Coil voltage code table".

Mounting characteristics and conditions for use


Contactor types AC operated A40 A50 A63 A75 A95 A110
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Max. built-in and add-on N.O. or N.C. auxiliary contacts:


see accessory fitting details for 3-pole contactor A40 ... A110
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc 0.85…1.1 x Uc
positions at θ ≤ 70 °C Uc 0.85…1.1 x Uc
6 at θ ≤ 55 °C 0.95...1.1 x Uc Unauthorized
at θ ≤ 70 °C Unauthorized Unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm or –
35 x 15 mm 75 x 25 mm
By screws (not supplied) 2 x M4 screws 2 x M6 screws 2 x M6 screws
placed diagonally placed diagonally placed diagonally 1SBC101878S0201

ABB | 3/21
A145 … A300 3-pole contactors
Technical data

Magnet system characteristics


Contactor types AC operated A145 A185 A210 A260 A300
Coil operating limits AC supply At θ ≤ 70 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage Rated control circuit voltage Uc at 50 Hz 24…690 V
at 60 Hz 24…690 V
Coil consumption Average pull-in value 50 Hz 550 VA 1350 VA
60 Hz 600 VA 1550 VA
3 50/60 Hz (1) 700 VA / 650 VA 1700 VA / 1550 VA
Average holding value 50 Hz 35 VA / 11 W 60 VA / 16 W
60 Hz 40 VA / 12 W 65 VA / 19 W
50/60 Hz (1) 44 VA / 13 W 80 VA / 21 W
Drop-out voltage Approx. 40…65 % of Uc min.
Operating time
Between coil energization and: N.O. contact closing 13…27 ms 17…35 ms
N.C. contact opening 8…22 ms 12…30 ms
Between coil de-energization and: N.O. contact opening 5…10 ms 7…13 ms
N.C. contact closing 9…13 ms 10…16 ms
(1) 50/60 Hz coils: see "Voltage code table".

Mounting characteristics and conditions for use


Contactor types AC operated A145 A185 A210 A260 A300
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor
A145 ... A300
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 70 °C 0.85 x Uc…1.1 x Uc
positions 6 Unauthorized
Mounting distances The contactors can be assembled side by side
Fixing On rail according to IEC 60715, EN 60715 –
By screws (not supplied) 4 x M5

1SFC101039C0201

3/22 | ABB
A9 ... A30 3-pole contactors
Technical data

Connecting characteristics
Contactor types AC operated A9 A12 A16 A26 A30
Main terminals

Screw terminals with cable clamp Screw terminals


with double
connector
2 x (5.6 x 6.5 mm) 3
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid Solid (≤ 4 mm²) 1x 1...4 mm² 1.5...6 mm² 2.5...16 mm²
Stranded (≥ 6 mm²) 2x 1...4 mm² 1.5...6 mm² 2.5...16 mm²
Flexible with ferrule 1x 0.75...2.5 mm² 0.75...4 mm² 2.5...10 mm²
2x 0.75...2.5 mm² 0.75...4 mm² 2.5...10 mm²
Bars or lugs L< 7.7 mm 10 mm -
l L
l< 3.7 mm 4.2 mm -
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18…10 AWG 12…8 AWG 8…4
Tightening torque Recommended 1 Nm / 9 Ib.in 1.7 Nm / 15 Ib.in 2.3 Nm / 20 Ib.in
Max. 1.2 Nm 2.20 Nm 2.60 Nm
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 7.7 mm (1) 8 mm
l L
l< 3.7 mm (1) 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18...14
Tightening torque
Coil terminals Recommended 1 Nm / 9 Ib.in
Max. 1.20 Nm
Built-in auxiliary Recommended 1 Nm / 9 Ib.in 1.7 Nm / 15 Ib.in 1 Nm / 9 Ib.in
terminals Max. 1.20 Nm 2.20 Nm 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP20
Coil terminals IP20
Built-in auxiliary terminals IP20
Screw terminals Delivered in open position, screws of unused terminals must be tightened
Main terminals M3.5 M4 M5
Screwdriver type Flat Ø 5.5 / Pozidriv 2 Flat Ø 6.5 / Pozidriv 2
Coil terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Built-in auxiliary terminals M3.5 M4 M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
(1) L ≤ 8 and l > 3.7 for coil terminals - L ≤ 10 and l > 4.2 for built-in auxiliary terminals.
1SBC101862S0201

ABB | 3/23
A40 ... A110 3-pole contactors
Technical data

Connecting characteristics
Contactor types AC operated A40 A50 A63 A75 A95 A110
Main terminals

Screw terminals Screw terminals Screw terminals


with double with single with single
connector connector connector
3 2 x (5.6 x 6.5 mm) (13 x 10 mm) (14 x 14 mm)
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid Solid (≤ 4 mm²) 1x 2.5...16 mm² 6...50 mm² 10...95 mm²
Stranded (≥ 6 mm²) 2x 2.5...16 mm² 6...25 mm² 6...35 mm²
Flexible with ferrule 1x 2.5...10 mm² 6...35 mm² 10…70 mm² (1)
2x 2.5...10 mm² 6...16 mm² 6…35 mm² (1)
Bars or lugs L< – – 30 mm (2)
l L
l< – – 6 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 8…4 AWG 8…1 AWG 6…2/0
Tightening torque Recommended 2.30 Nm / 20 lb.in 4.00 Nm / 35 lb.in 8 Nm / 71 lb.in
Max. 2.60 Nm 4.50 Nm 9 Nm
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid 1x 1…4 mm² 0.75…2.5 mm²
2x 1…4 mm² 0.75…2.5 mm²
Flexible with ferrule 1x 0.75…2.5 mm² 1…2.5 mm² 0.75…2.5 mm²
2x 0.75…2.5 mm²
Lugs L< 8 mm
l L
l< 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18...14
Tightening torque
Coil terminals Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Built-in auxiliary Recommended 1.00 Nm / 9 lb.in – –
terminals Max. 1.20 Nm – –
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP20 IP10
Coil terminals IP20
Built-in auxiliary terminals IP20 – –
Screw terminals Delivered in open position, screws of unused terminals must be tightened
Main terminals M5 M6 M8
Screwdriver type Flat Ø 6.5 / Pozidriv 2 Hexagon socket (s = 4 mm)
Coil terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Built-in auxiliary terminals M3.5 –
Screwdriver type Flat Ø 5.5 / Pozidriv 2 –
(1) A95 / A110: use flexible without ferrule.
(2) With LW110 enlargement piece, see "Accessories".
1SBC101879S0201

3/24 | ABB
A145 … A300 3-pole contactors
Technical data

Connecting characteristics
Contactor types AC operated A145 A185 A210 A260 A300
Main terminals 17.5
20
Flat type 5
5

E1859D
E1858D
ø 8.5 ø 10.2
3
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid with Single for Cu cable 6…185 mm² 16…240 mm²
connector Single for Al/Cu cable 25…150 mm² 120…240 mm²
Double for Al/Cu cable – 2 x 95…120 mm²
Bars or lugs L ≤ 24 mm 32 mm
ø L
Ø > 8 mm 10 mm
Connection capacity acc. to UL / CSA 1 or 2 x 6 - 250 MCM 4 - 500 MCM (1)
Tightening torque Recommended 18 Nm / 160 Ib.in 28 Nm / 247 lb.in
Max. 20 Nm 30 Nm
Auxiliary conductors
(coil terminals)
Rigid solid 1x 1…4 mm²
2x 1…4 mm²
Flexible with ferrule 1x 0.75…2.5 mm²
2x 0.75…2.5 mm²
Lugs L≤ 8 mm
l L
l> 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18…14
Tightening torque Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP00
Coil terminals IP20
Screw terminals
Main terminals M8 M10
Screws and bolts
Coil terminals (delivered in open position) M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
(1) With LW110 enlargement piece: see "Accessories".

1SFC101152C0201

ABB | 3/25
A9 ... A40 3-pole contactors
Technical data

Built-in auxiliary contacts according to IEC - Other auxiliary contacts see "Accessories"
Contactor types AC operated A9 A12 A16 A26 A30 A40
Rated operational voltage Ue max. 690 V
Rated frequency (without derating) 50/60 Hz
Conventional free air thermal current Ith - θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
3 380-440 V 50/60 Hz 3A
500 V 50/60 Hz 2A
690 V 50/60 Hz 2A
Making capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 6 A / 144 W
48 V DC 2.8 A / 134 W
72 V DC 2 A / 144 W
110 V DC 1.1 A / 121 W
125 V DC 1.1 A / 138 W
220 V DC 0.55 A / 121 W
250 V DC 0.55 A / 138 W
Short-circuit protection device gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
for 0.1 s 140 A
Minimum switching capacity 17 V / 5 mA
with failure rate acc. to IEC 60947-5-4 ≤ 10-7 for AL40 and TAL40 contactors
Non-overlapping time between N.O. and N.C. contacts ≥ 2 ms
Power dissipation per pole at 6 A 0.1 W
Max. electrical switching frequency AC-15 1200 cycles/h
DC-13 900 cycles/h
Mechanically linked contacts Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts of 4-pole CA5 are
acc. to annex L of IEC 60947-5-1 mechanically linked contacts.
Mirror contacts Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA5, CAL5-11) are mirror contacts.
acc. to annex F of IEC 60947-4-1

Built-in auxiliary contacts according to UL / CSA


Contactor types AC operated A9 A12 A16 A26 A30 A40
Max. operational voltage 600 V AC, 600 V DC
Pilot duty A600, P300
AC thermal rated current 10 A
AC maximum volt-ampere making 7200 VA
AC maximum volt-ampere breaking 720 VA
DC thermal rated current 5A
DC maximum volt-ampere making-breaking 138 VA
1SBC101880S0201

3/26 | ABB
A9 ... A300 3-pole contactors
Terminal marking and positioning

A9 ... A110 contactors - AC operated


Standard devices without addition of auxiliary contacts
A1 A2 A1 A2
1L1 3L2 5L3 13 1L1 3L2 5L3 21
NO NC

A1 1L1 3L2 5L3 13 A1 1L1 3L2 5L3 21


NO NC

2T1 4T2 6T3 14


NO

2T1 4T2 6T3 22


NC
3
NO NC
A2 A2 A2 2T1 4T2 6T3 14 A2 2T1 4T2 6T3 22

A9 ... A40-30-10 A9 ... A40-30-01 A9 ... A40-30-10 A9 ... A40-30-01

Standard devices with factory mounted auxiliary contacts


A1 A2
1L1 3L2 5L3

NO 13X

NC 21X

A1 1L1 3L2 5L3 13X 21X


NC 22X NO NC
NO 14X

6T3 NO NC
2T1 4T2 A2 2T1 4T2 6T3 14X 22X
A2
A50 ... A110-30-11
A50 ... A110-30-11

Other possible contact combinations with auxiliary contacts added by the user A1 1L1 3L2 5L3 13 21
NO NC
A1 A2 A1 A2 A1 A2 A1 A2
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13
NO NO NO NO NO NC
A2 2T1 4T2 6T3 14 22

21 2- -1 21 33 2- 3- -1 -3 Combination 11
NC = + NC NC NO = + NC + NO
22 2- -2 22 34 2- 3- -2 -4
A1 1L1 3L2 5L3 13 21 33
NO NC NO
NO NO NO NO

2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14
A2 A2 A2 A2 NO NC NO
A2 2T1 4T2 6T3 14 22 34

Combination 11 = A9 ... A40-30-10 + CA5-01 Combination 21 = A9 ... A40-30-10 + CA5-01 + CA5-10 Combination 21

A1 A2 A1 A2
1L1 3L2 5L3 1L1 3L2 5L3

13X 43X NO 13X 43X NO


21X 31X NC 21X 31X NC
= +
22X 32X NC 22X 32X NC

14X 44X NO 14X 44X NO

2T1 4T2 6T3 2T1 4T2 6T3


A2 A2

Combination 22 = A50 ... A75-30-11 + CAL5-11

A145 ... A300 contactors - AC operated


Standard devices with factory mounted auxiliary contacts
1L1 3L2 5L3

A1 A2

NO 13X
NC 21X

NC 22X
NO 14X

1L1 3L2 5L3 13X 21X


1SBC101881S0201

A1
NO NC

NO NC
2T1 4T2 6T3 A2 2T1 4T2 6T3 14X 22X

A145 ... A300-30-11 A145 ... A300-30-11

ABB | 3/27
Star-delta starting of three-phase asynchronous motors
Contactor selection

General
Star-delta starting is the most common method to reduce the starting current of a motor. This system can be used on all the
squirrel cage motors, which are normally used in delta connection.
In this type of starting, it is recommended to choose motors having high starting torque i.e. much higher than the resistive
torque in order to reach sufficient high speed when the motor is connected in star.

Star-delta starting
3
I
/In T
/Tn Technical Data
7 When starting:
I = current; In = nominal current –– inrush current is reduced to a third of direct starting current
T = torque; Tn = nominal torque –– motor torque is reduced to a third or even less of direct
6
starting torque.
I (delta)
Transient current is generated when switching from star to delta con-
5
nection.

Utilization
4 During the initial starting phase ("star" connection), the resistive torque
of the driven load must remain, irrespective of speed, less than the
"star" motor torque until "star-delta" switching occurs.
3 This starting mode is therefore ideal for machines having low starting
torque such as:
T ( m ot –– pumps
2 or
) –– centrifugal compressors
I (sta
r) –– wood-working machines, etc.
1 In order to prevent a high current peak, at least 85 % of nominal
T (motor) speed must be reached before switching from star to delta.
Tr (resistive torque)
Precautions
0 20 40 60 80 100 Motor nominal voltage in delta connection must be equal to that of the
Motor speed (%) mains.

Example:
A motor for 400 V star-delta starting must be designed for 400 V in "delta" connection. Its usual designation is "400 V / 690 V
motor". The motor must be constructed with 6 terminal windings.

Sequence
Starting is a three-stage process:
1st stage - "Star" connection
Press the "On" button on the control circuit to close the KM2 "star" contactor. The KM1 "line" contactor then closes and the
motor starts. Countdown of programmed starting time (normally 6 to 10 s) then begins.
2nd stage - "Star" to "Delta" switching
When the programmed starting time is over, the KM2 "star" contactor opens.
3rd stage - "Delta" connection
A transition time (or dwelling time) of 50 ms is fixed between opening of the "star" contactor and closing of the "delta" contac-
tor by the use of TE5S timer. This prevents short circuit between "star" and "delta".

Note: An electrical interlock between star and delta is mandatory such as VE 5 or through auxiliary contacts.
Furthermore, in open transition, the current interruption may reach up to 95 ms: it shall be checked that this duration is compatible with the application i.e. mainly if the decreasing
in rotation speed is acceptable during the starting phase.
1SBC101882S0201

3/28 | ABB
Star-delta starting of three-phase asynchronous motors
Contactor selection

Rated operational power (1) Max. starting Line Delta Star Overload Timer
230 V 400 V 415 V 500 V 690 V time from a contactor contactor contactor relay (3)
AC-3 AC-3 AC-3 AC-3 AC-3 cold state (2) KM1 KM3 KM2
kW kW kW kW kW seconds Type Type Type Type Type
4 7.5 7.5 5.5 5.5 15 A9 A9 A9 TA25DU-M TE5S
5.5 11 11 7.5 7.5 15 A12 A12 A9 TA25DU-M TE5S
9 15 15 15 11 15 A16 A16 A12 TA25DU-M TE5S
12.5 22 22 22 15 15 A26 A26 A16 TA25DU-M TE5S
15 25 25 25 18.5 15 A30 A30 A26 TA25DU-M TE5S 3
18.5 37 37 37 37 30 A40 A40 A26 TA42DU-M TE5S
25 45 45 45 45 30 A50 A50 A30 TA75DU-M TE5S
30 55 55 63 59 30 A63 A63 A40 TA75DU-M TE5S
37 63 70 75 63 30 A75 A75 A50 TA75DU-M TE5S
45 75 75 90 90 20 A95 A95 A75 TA110DU TE5S
55 90 100 110 132 20 A110 A110 A95 TA110DU TE5S
75 132 132 160 160 20 A145 A145 A110 TA200DU TE5S
90 160 160 200 250 20 A185 A185 A145 TA200DU TE5S
110 200 200 250 315 20 A210 A210 A185 TA450DU TE5S
140 220 250 295 355 20 A260 A260 A210 TA450DU TE5S
160 250 250 355 450 20 A300 A300 A260 TA450DU TE5S
Notes:
(1) Ambient temperature ≤ 55 °C for A9 ... A300
(2) Usual time value = 6...10 s.
(3) The setting current value is: nominal motor current x 0.58.

For motors above 670 kW / 400 V, it is recommended to use Closed Transition Star-Delta starting. Contact your ABB Office for selection.

Power circuit diagram Control circuit diagrams - Remote control

A9 ... A300 contactors A9 ... A300 contactors


L1 L2 L3
KM3 : 5/L3 KM3 : 5/L3
Us Us

1 3 5 1 3 5
95

95

1 3 5
KM2 / (Y) KM3 / ( ) KM1 / (L)
FR1 FR1
2 4 6
2 4 6 2 4 6
96

96

1 3 5

2 4 6 O O

W2 W1
V2 V1
23

23

U2 U1

I KM1 I KM1
24

24

W2 W1
V2 V1
KT TE5S electronic Timer KT Standard Timer
A1
15

U2 U1
E0514D1

Dwelling time = 50 ms Without dwelling time

Contactor relay + TEF electronic timer


t1 t1+t2 or C565 electronic timer
A2
16

18
21

21

13

13

21

21

13

13

KM3 KM2 KM2 KM1 KM3 KM2 KM2 KM1


22
22

22

14

14

22

14

14
A1

A1

A1

A1

A1

A1

KM2 KM3 KM1 KM2 KM3 KM1


Y L Y L
A2

A2

A2

A2
A2

A2

Us Us
N N
KM3 : 3/L2 KM3 : 3/L2
1SBC101883S0201

ABB | 3/29
4-pole contactors

IEC AC-1 Rated operational current θ ≤ 40 °C, 690 V A 25 30 45 70 100 125


3
UL/CSA General use rating 600 V A 21 30 40 65 80 105

AC Control supply Type A9 A16 A26 A45 A50 A75

IEC AC-1 Rated operational current θ ≤ 40 °C A 25 30 45 70 100 125


θ ≤ 55 °C A 22 27 40 60 85 105
θ ≤ 70 °C A 18 23 32 50 70 85
With conductor cross sectional area mm 2 2.5 4 6 25 35 50
Rated operational voltage Ue max. V 690 690 690 1000 1000 1000

Main accessories
Auxiliary contact blocks Front mounting CA5-10 (1 x N.O.)
CA5-01 (1 x N.C.)
Side mounting CAL5-11 (1 x N.O. + 1 x N.C.)
Timers Electronic TEF5-ON
TEF5-OFF
TE5S (for star-delta starters - direct timing - separate mounting)
Interlocking units Mechanical VM5-1
Mechanical / Electrical VE5-1 VE5-2
Surge suppressors Varistor (AC / DC) RV5 (24...440 V)
RC Type (AC) RC5-1 (24...440 V) RC5-2 (24...440 V)

1SBC101884S0201.indd
1SBC101884S0201

3/30 | ABB ABB | 1/5


A9 ... A16 4-pole contactors
25 to 30 A AC-1
AC operated
Description
A9 ... A16 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e.
resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC.
These contactors are of the block type design with:
1SBC573142F0301

–– 4 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
A9-40-00 3
Ordering details
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational General use voltage contacts
current rating Uc fitted Pkg
θ ≤ 40 °C 600 V AC (1) (1 pce)
AC-1
A A V 50 Hz V 60 Hz kg
4 N.O. main poles
25 21 24 24 0 0 A9-40-00 1SBL141201R8100 0.340
48 48 0 0 A9-40-00 1SBL141201R8300 0.340
110 110…120 0 0 A9-40-00 1SBL141201R8400 0.340
220…230 230…240 0 0 A9-40-00 1SBL141201R8000 0.340
230…240 240…260 0 0 A9-40-00 1SBL141201R8800 0.340
380…400 400…415 0 0 A9-40-00 1SBL141201R8500 0.340
400…415 415…440 0 0 A9-40-00 1SBL141201R8600 0.340
30 30 24 24 0 0 A16-40-00 1SBL181201R8100 0.340
48 48 0 0 A16-40-00 1SBL181201R8300 0.340
110 110…120 0 0 A16-40-00 1SBL181201R8400 0.340
220…230 230…240 0 0 A16-40-00 1SBL181201R8000 0.340
230…240 240…260 0 0 A16-40-00 1SBL181201R8800 0.340
380…400 400…415 0 0 A16-40-00 1SBL181201R8500 0.340
400…415 415…440 0 0 A16-40-00 1SBL181201R8600 0.340
2 N.O. + 2 N.C. main poles (2)
25 21 24 24 0 0 A9-22-00 1SBL141501R8100 0.340
48 48 0 0 A9-22-00 1SBL141501R8300 0.340
110 110…120 0 0 A9-22-00 1SBL141501R8400 0.340
220…230 230…240 0 0 A9-22-00 1SBL141501R8000 0.340
230…240 240…260 0 0 A9-22-00 1SBL141501R8800 0.340
380…400 400…415 0 0 A9-22-00 1SBL141501R8500 0.340
400…415 415…440 0 0 A9-22-00 1SBL141501R8600 0.340
30 30 24 24 0 0 A16-22-00 1SBL181501R8100 0.340
48 48 0 0 A16-22-00 1SBL181501R8300 0.340
110 110…120 0 0 A16-22-00 1SBL181501R8400 0.340
220…230 230…240 0 0 A16-22-00 1SBL181501R8000 0.340
230…240 240…260 0 0 A16-22-00 1SBL181501R8800 0.340
380…400 400…415 0 0 A16-22-00 1SBL181501R8500 0.340
400…415 415…440 0 0 A16-22-00 1SBL181501R8600 0.340
(1) Other control voltages see voltage code table.
(2) T
 hese contactors are not suitable for a reversing starter or star-delta starter or for controlling a single load from 2 separate supplies.
Please see technical data.

Main dimensions mm, inches


74 2.91"

68 2.68"
5.5 0.22"
35 mm EN/IEC 60715
74 2.91"

1SBC101857S0201

44 1.73" 4 10
0.16" 0.39"
A9, A16

ABB | 3/31
A26 4-pole contactors
45 A AC-1
AC operated
Description
A26 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance
furnaces...) and generally for controlling power circuits up to 690 V AC and 220 V DC.
These contactors are of the block type design with:
1SBC573081F0301

–– 4 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
3 A26-40-00
Ordering details
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational General use voltage contacts
current rating Uc fitted Pkg
θ ≤ 40 °C 600 V AC (1) (1 pce)
AC-1
A A V 50 Hz V 60 Hz kg
4 N.O. main poles
45 40 24 24 0 0 A26-40-00 1SBL241201R8100 0.610
48 48 0 0 A26-40-00 1SBL241201R8300 0.610
110 110…120 0 0 A26-40-00 1SBL241201R8400 0.610
220…230 230…240 0 0 A26-40-00 1SBL241201R8000 0.610
230…240 240…260 0 0 A26-40-00 1SBL241201R8800 0.610
380…400 400…415 0 0 A26-40-00 1SBL241201R8500 0.610
400…415 415…440 0 0 A26-40-00 1SBL241201R8600 0.610
2 N.O. + 2 N.C. main poles (2)
45 40 24 24 0 0 A26-22-00 1SBL241501R8100 0.610
48 48 0 0 A26-22-00 1SBL241501R8300 0.610
110 110…120 0 0 A26-22-00 1SBL241501R8400 0.610
220…230 230…240 0 0 A26-22-00 1SBL241501R8000 0.610
230…240 240…260 0 0 A26-22-00 1SBL241501R8800 0.610
380…400 400…415 0 0 A26-22-00 1SBL241501R8500 0.610
400…415 415…440 0 0 A26-22-00 1SBL241501R8600 0.610
(1) Other control voltages see voltage code table.
(2) T
 hese contactors are not suitable for a reversing starter or star-delta starter or for controlling a single load from 2 separate supplies.
Please see technical data.

Main dimensions mm, inches


93.6 3.69"

9 0.35" 6.3 0.25"


35 mm EN/IEC 60715
90 3.54"

1SBC101863S0201

54 2.13" 4 0.16" 10 0.39"

A26

3/32 | ABB
A45 … A75 4-pole contactors
70 to 125 A AC-1
AC operated
Description
A45 ... A75 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e.
resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 220 V DC.
These contactors are of the block type design with:
1SBC580873F0301

–– 4 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

Ordering details
3
A45-40-00
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
Rated operational General use voltage contacts
current rating Uc fitted Pkg
θ ≤ 40 °C 600 V AC (1) (1 pce)
AC-1
A A V 50 Hz V 60 Hz kg
4 N.O. main poles
70 65 24 24 0 0 A45-40-00 1SBL331201R8100 1.390
48 48 0 0 A45-40-00 1SBL331201R8300 1.390
110 110…120 0 0 A45-40-00 1SBL331201R8400 1.390
220…230 230…240 0 0 A45-40-00 1SBL331201R8000 1.390
230…240 240…260 0 0 A45-40-00 1SBL331201R8800 1.390
380…400 400…415 0 0 A45-40-00 1SBL331201R8500 1.390
400…415 415…440 0 0 A45-40-00 1SBL331201R8600 1.390
100 80 24 24 0 0 A50-40-00 1SBL351201R8100 1.390
48 48 0 0 A50-40-00 1SBL351201R8300 1.390
110 110…120 0 0 A50-40-00 1SBL351201R8400 1.390
220…230 230…240 0 0 A50-40-00 1SBL351201R8000 1.390
230…240 240…260 0 0 A50-40-00 1SBL351201R8800 1.390
380…400 400…415 0 0 A50-40-00 1SBL351201R8500 1.390
400…415 415…440 0 0 A50-40-00 1SBL351201R8600 1.390
125 105 24 24 0 0 A75-40-00 1SBL411201R8100 1.390
48 48 0 0 A75-40-00 1SBL411201R8300 1.390
110 110…120 0 0 A75-40-00 1SBL411201R8400 1.390
220…230 230…240 0 0 A75-40-00 1SBL411201R8000 1.390
230…240 240…260 0 0 A75-40-00 1SBL411201R8800 1.390
380…400 400…415 0 0 A75-40-00 1SBL411201R8500 1.390
400…415 415…440 0 0 A75-40-00 1SBL411201R8600 1.390
2 N.O. + 2 N.C. main poles (2)
70 65 24 24 0 0 A45-22-00 1SBL331501R8100 1.400
48 48 0 0 A45-22-00 1SBL331501R8300 1.400
110 110…120 0 0 A45-22-00 1SBL331501R8400 1.400
220…230 230…240 0 0 A45-22-00 1SBL331501R8000 1.400
230…240 240…260 0 0 A45-22-00 1SBL331501R8800 1.400
380…400 400…415 0 0 A45-22-00 1SBL331501R8500 1.400
400…415 415…440 0 0 A45-22-00 1SBL331501R8600 1.400
125 105 24 24 0 0 A75-22-00 1SBL411501R8100 1.400
48 48 0 0 A75-22-00 1SBL411501R8300 1.400
110 110…120 0 0 A75-22-00 1SBL411501R8400 1.400
220…230 230…240 0 0 A75-22-00 1SBL411501R8000 1.400
230…240 240…260 0 0 A75-22-00 1SBL411501R8800 1.400
380…400 400…415 0 0 A75-22-00 1SBL411501R8500 1.400
400…415 415…440 0 0 A75-22-00 1SBL411501R8600 1.400
(1) Other control voltages see voltage code table.
(2) These contactors are not suitable for a reversing starter or star-delta starter or for controlling a single load from 2 separate supplies.
Please see technical data.

Main dimensions mm, inches


35 mm x 15 EN/IEC 60715

119.5 4.7"
6 0.24" 6.5 0.26"
110 4.33"

4
0.16"
75 mm EN/IEC 60715

1SBC101377S0201

92 3.62" 10 0.39" 10 0.39"

A45, A50, A75

ABB | 3/33
A9 … A75 4-pole contactors
Main accessories

Contactor and main accessories (other accessories available)

RV5, RC5
Surge suppressor

3
A contactor

VE5
Interlock unit A2
A1

TEF5
Electronic timer

BX4-CA
Protective cover

CAL
2-pole auxiliary CA5
contact block 4-pole auxiliary
contact block

CA5
1-pole auxiliary
contact block

Main accessory fitting details


Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor Main Built-in Front-mounted accessories Side-mounted accessories
types poles auxiliary Auxiliary contact blocks Electronic timer Auxiliary contact blocks Interlock unit
contacts

1-pole CA5 4-pole CA5 TEF5 2-pole CAL5-11 VM5 or VE5


A9, A16 4 0 0 0 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 or 1 x VM5-1 or VE5-1
+ 1 x CAL5-11
2 2 0 0 (1) 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 –

A26 4 0 0 0 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 or 1 x VM5-1 or VE5-1


+ 1 x CAL5-11
2 2 0 0 (1) 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 –

A45 ... A75 4 0 0 0 1 to 6 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 or 1 x VE5-2


+ 2 x 1-pole CA5 + 2 x CA5 (1-pole) + 1 x CAL5-11
2 2 0 0 (2) 1 to 6 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11 –
+ 2 x 1-pole CA5 + 2 x CA5 (1-pole)

(1) 2 N.C. CA5 auxiliary contacts maximum in mounting position 5.


(2) 2 N.C. CA5 auxiliary contacts maximum.
1SBC101873S0201

3/34 | ABB
A9 … A75 4-pole contactors
Main accessories

Ordering details (1)


1SBC580992F0301

For contactors Auxiliary Type Order code Pkg Weight


contacts qty (1 pce)

CA5-10 kg

Front-mounted instantaneous auxiliary contact blocks


A9 ... A75 1 – CA5-10 1SBN010010R1010 10 0.014
– 1 CA5-01 1SBN010010R1001 10 0.014 3
A9 ... A75 2 2 CA5-22E 1SBN010040R1022 2 0.060
1SBC573752F0301

Side-mounted instantaneous auxiliary contact block


A9 … A75 1 1 CAL5-11 1SBN010020R1011 2 0.050

Interlock units
CAL5-11 A9 ... A26 Mechanical – – VM5-1 1SBN030100R1000 1 0.066
Mechanical and electrical – 2 VE5-1 1SBN030110R1000 1 0.076
A45 ... A75 Mechanical and electrical – 2 VE5-2 1SBN030210R1000 1 0.146
01 01
NC NC

02 02

VE5-2 For contactors Time delay Delay Auxiliary Type Order code Pkg Weight
Terminal marking and positioning range type contacts qty (1 pce)
selected by
switch
kg

Electronic timers
A9 … A75 0.1...1 s ON-delay 1 1 TEF5-ON 1SBN020312R1000 1 0.065
1...10 s
10...100 s OFF-delay 1 1 TEF5-OFF 1SBN020314R1000 1 0.065

Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.


1SBC101396F0014

For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V AC DC kg

TEF5-OFF Surge suppressors


A9 … A75 24...50 ● ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● ● RV5/250 1SBN050010R1002 2 0.015
250...440 ● ● RV5/440 1SBN050010R1003 2 0.015
A9 … A26 24...50 ● – RC5-1/50 1SBN050100R1000 2 0.012
1SBC574001F0301

50...133 ● – RC5-1/133 1SBN050100R1001 2 0.012


110...250 ● – RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● – RC5-1/440 1SBN050100R1003 2 0.012
A45 … A75 24...50 ● – RC5-2/50 1SBN050200R1000 2 0.015
50...133 ● – RC5-2/133 1SBN050200R1001 2 0.015
RV5/50 110...250 ● – RC5-2/250 1SBN050200R1002 2 0.015
250...440 ● – RC5-2/440 1SBN050200R1003 2 0.015
(1) See "Main accessory fitting details" table.
1SBC101874S0201

ABB | 3/35
A9 ... A26 4-pole contactors
Technical data

Main pole - Utilization characteristics according to IEC


Contactor types AC operated A9 A16 A26
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
Rated operational voltage Ue max. 690 V
Rated frequency (without derating) 50 / 60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 26 A 30 A 45 A
With conductor cross-sectional area 4 mm² 4 mm² 6 mm²
3 AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C 25 A 30 A 45 A
Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C 22 A 27 A 40 A
θ ≤ 70 °C 18 A 23 A 32 A
With conductor cross-sectional area 2.5 mm² 4 mm² 6 mm²
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V 9 A 17 A 26 A
380-400 V 9 A 17 A 26 A
415 V 9 A 17 A 26 A
M 3-phase motors
440 V 9 A 16 A 26 A
3
500 V 9 A 14 A 22 A
690 V 7 A 10 A 17 A
Rated operational power AC-3 (1)
220-230-240 V 2.2 kW 4 kW 6.5 kW
380-400 V 4 kW 7.5 kW 11 kW
1500 r.p.m. 50 Hz 415 V 4 kW 9 kW 11 kW
M 1800 r.p.m. 60 Hz
3-phase motors 440 V 4 kW 9 kW 15 kW
3
500 V 5.5 kW 9 kW 15 kW
690 V 5.5 kW 9 kW 15 kW
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1
Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse 25 A 32 A 50 A
Rated short-time withstand current Icw 1 s 250 A 300 A 400 A
at 40 °C ambient temperature, 10 s 100 A 140 A 210 A
in free air from a cold state 30 s 60 A 80 A 110 A
1 min 50 A 60 A 90 A
15 min 26 A 30 A 45 A
Power dissipation per pole Ie / AC-1 0.8 W 1.2 W 1.8 W
Ie / AC-3 0.1 W 0.35 W 0.6 W
Max. electrical switching frequency AC-1 600 cycle/h
AC-3 1200 cycle/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".

Main pole - Utilization characteristics according to UL / CSA


Contactor types AC operated A9 A16 A26
Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V
UL / CSA general use rating
600 V AC 21 A 30 A 40 A
With conductor cross-sectional area AWG 10 AWG 8
Max. electrical switching frequency
For general use 600 cycles/h
1SBC101864S0201

3/36 | ABB
A45 ... A75 4-pole contactors
Technical data

Main pole - Utilization characteristics according to IEC


Contactor types AC operated A45 A50 A75
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
Rated operational voltage Ue max. 1000 V
Rated frequency (without derating) 50 / 60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 100 A 100 A 125 A
With conductor cross-sectional area 35 mm² 35 mm² 50 mm²
AC-1 Utilization category
3
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C 70 A 100 A 125 A
Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C 60 A 85 A 105 A
θ ≤ 70 °C 50 A 70 A 85 A
With conductor cross-sectional area 25 mm² 35 mm² 50 mm²
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V 40 A 53 A 75 A
380-400 V 37 A 50 A 75 A
415 V 37 A 50 A 75 A
M 3-phase motors 440 V 37 A 45 A 70 A
3 500 V 33 A 45 A 65 A
690 V 25 A 35 A 46 A
1000 V – 23 A 28 A
Rated operational power AC-3 (1)
220-230-240 V 11 kW 15 kW 22 kW
380-400 V 18.5 kW 22 kW 37 kW
415 V 18.5 kW 25 kW 40 kW
1500 r.p.m. 50 Hz
M 1800 r.p.m. 60 Hz 440 V 22 kW 25 kW 40 kW
3 3-phase motors 500 V 22 kW 30 kW 45 kW
690 V 22 kW 30 kW 40 kW
1000 V – 30 kW 37 kW
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1
Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse 80 A 100 A 160 A
Rated short-time withstand current Icw 1 s 1000 A
at 40 °C ambient temperature, 10 s 650 A
in free air from a cold state 30 s 370 A
1 min 250 A
15 min 110 A 110 A 135 A
Power dissipation per pole Ie / AC-1 2.5 W 5W 7W
Ie / AC-3 0.65 W 1.3 W 2W
Max. electrical switching frequency AC-1 600 cycles/h
AC-3 600 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".

Main pole - Utilization characteristics according to UL / CSA


Contactor types AC operated A45 A50 A75
Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V
UL / CSA general use rating
600 V AC 65 A 80 A 105 A
With conductor cross-sectional area AWG 6 AWG 4 AWG 2
Max. electrical switching frequency
For general use 600 cycles/h
1SBC101885S0201

ABB | 3/37
A9 ... A26 4-pole contactors
Technical data

Magnet system characteristics


Contactor types AC operated A9 A16 A26
Coil operating limits AC supply at θ ≤ 55 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage 50/60 Hz
Rated control circuit voltage Uc at 50 Hz 24...690 V
at 60 Hz 24...690 V
Coil consumption Average pull-in value 50 Hz 70 VA 120 VA
3 60 Hz 80 VA 140 VA
50/60 Hz (1) 74 VA / 70 VA 125 VA / 120 VA
Average holding value 50 Hz 8 VA / 2 W 12 VA / 3 W
60 Hz 8 VA / 2 W 12 VA / 3 W
50/60 Hz (1) 8 VA / 2 W 12 VA / 3 W
Drop-out voltage approx. 40...65 % of Uc
Operating time
Between coil energization and: N.O. contact closing 10...26 ms 8...21 ms
N.C. contact opening 7...21 ms 6...18 ms
Between coil de-energization and: N.O. contact opening 4...11 ms 4...11 ms
N.C. contact closing 9...16 ms 7...14 ms
(1) 50/60 Hz coils: see "Coil voltage code table".

Mounting characteristics and conditions for use


Contactor types AC operated A9 A16 A26
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for 4-pole contactor A9 ... A26
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc
positions at θ ≤ 70 °C Uc
6 at θ ≤ 55 °C 0.95…1.1 x Uc
at θ ≤ 70 °C unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
By screws (not supplied) 2 x M4 screws placed diagonally
1SBC101865S0201

3/38 | ABB
A45 ... A75 4-pole contactors
Technical data

Magnet system characteristics


Contactor types AC operated A45 A50 A75
Coil operating limits AC supply At θ ≤ 55 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage
Rated control circuit voltage Uc at 50 Hz 24…690 V
at 60 Hz 24…690 V
Coil consumption Average pull-in value 50 Hz 180 VA
60 Hz 210 VA
3
50/60 Hz (1) 190 VA / 180 VA
Average holding value 50 Hz 18 VA / 5.5 W
60 Hz 18 VA / 5.5 W
50/60 Hz (1) 18 VA / 5.5 W
Drop-out voltage approx. 40...65 % of Uc
Operating time
Between coil energization and: N.O. contact closing 8…27 ms
N.C. contact opening 7…22 ms
Between coil de-energization and: N.O. contact opening 4…11 ms
N.C. contact closing 7…14 ms
(1) 50/60 Hz coils: see "Coil voltage code table".

Mounting characteristics and conditions for use


Contactor types AC operated A45 A50 A75
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Pos. 5 unauthorized for A45-22-00, A75-22-00


Max. add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for 4-pole contactor A45 ... A75
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc
positions (1) at θ ≤ 70 °C Uc
6 at θ ≤ 55 °C 0.95…1.1 x Uc
at θ ≤ 70 °C Unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 35 x 15 mm or 75 x 25 mm
By screws (not supplied) 2 x M6 screws placed diagonally
(1) For 60 Hz coil voltage: (only for devices fitted with CA 5-.. and CAL 5-11 auxiliary contacts).
– A45-40-00, A50-40-00 and A75-40-00 contactors.
Mounting positions 1 to 5 and ambient temperature ≤ 55 °C: tolerance reduced to 0.9...1.1 Uc (instead of 0.85...1.1 Uc) for coil voltage codes 70 to 79 and 80 to 89.
– A45-22-00 and A75-22-00 contactors.
Mounting positions 1 to 4 and ambient temperature ≤ 55 °C: tolerance reduced to 0.9...1.1 Uc (instead of 0.85...1.1 Uc) for coil voltage codes 70 to 79 and 80 to 89.
For mounting position 6 or ambient temperature of 55 to 70 °C the information given on this page remains applicable.
1SBC101550S0201 - Rev. B

ABB | 3/39
A9 ... A26 4-pole contactors
Technical data

General technical data


Contactor types AC operated A9 A16 A26
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature close to contactor
Operation in free air -40...+70 °C
3 Storage
Climatic withstand
-60...+80 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles 10 millions operating cycles
Max. switching frequency 3600 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1 Shock direction 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
A 20 g
A A B1 B2 B1 10 g closed position / 5 g open position
B2 15 g
C1 20 g
C2 C2 20 g

Remark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles

1 R3 R5 7
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising
2 separate loads with a single supply (see diagrams below). When the contactor operates there is no mechanical overlapping
between the N.O. poles and the N.C. poles: BREAK before MAKE.

2 R4 R6 8

! These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.

Block diagrams
– Single supply and 2 separate loads – 2 separate supplies and 2 separate loads
Supply Main
supply
Back-up
supply

A1 1 R3 R5 7 A1 1 R3 R5 7
1SBC101866S0201

A2 2 R4 R6 8 A2 2 R4 R6 8
Load Load
Load Load

3/40 | ABB
A45 ... A75 4-pole contactors
Technical data

General technical data


Contactor types AC operated A45 A50 A75
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature close to contactor
Operation in free air -40...+70 °C
Storage
Climatic withstand
-60...+80 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
3
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles 10 millions operating cycles
Max. switching frequency 3600 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1 Shock direction 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
A 20 g
A A B1 B2 B1 10 g closed position / 5 g open position
B2 15 g
C1 20 g
C2 C2 20 g

Remark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles

1 R3 R5 7
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising
2 separate loads with a single supply (see diagrams below). When the contactor operates there is no mechanical overlapping
between the N.O. poles and the N.C. poles: BREAK before MAKE.

2 R4 R6 8

! These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.

Block diagrams
– Single supply and 2 separate loads – 2 separate supplies and 2 separate loads
Supply Main
supply
Back-up
supply

A1 1 R3 R5 7 A1 1 R3 R5 7
1SBC101886S0201

A2 2 R4 R6 8 A2 2 R4 R6 8
Load Load
Load Load

ABB | 3/41
A9 ... A26 4-pole contactors
Technical data

Connecting characteristics
Contactor types AC operated A9 A16 A26
Main terminals

Screw terminals with cable clamp


Connection capacity (min. ... max.)
Main conductors (poles)
3 Rigid Solid (≤ 4 mm²) 1x 1...4 mm² 1.5...6 mm²
Stranded (≥ 6 mm²) 2x 1...4 mm² 1.5...6 mm²
Flexible with ferrule 1x 0.75...2.5 mm² 0.75...4 mm²
2x 0.75...2.5 mm² 0.75...4 mm²
Bars or lugs L< 7.7 mm 10 mm
l L
l< 3.7 mm 4.2 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18…10 AWG 12…8
Tightening torque Recommended 1 Nm / 9 Ib.in 1.7 Nm / 15 Ib.in
Max. 1.2 Nm 2.2 Nm
Auxiliary conductors
(coil terminals)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 7.7 mm (1)
l L
l< 3.7 mm (1)
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18...14
Tightening torque Recommended 1 Nm / 9 Ib.in
Max. 1.2 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP20
Coil terminals IP20
Screw terminals Delivered in open position, screws of unused terminals must be tightened
Main terminals M3.5 M4
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Coil terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
(1) L ≤ 8 and l > 3.7 for coil terminals - L ≤ 10 and l > 4.2 for built-in auxiliary terminals.

1SBC101867S0201

3/42 | ABB
A45 ... A75 4-pole contactors
Technical data

Connecting characteristics
Contactor types AC operated A45 A50 A75
Main terminals

Screw terminals with single connector


(13 x 10 mm)
Connection capacity (min. ... max.)
Main conductors (poles) 3
Rigid Solid (≤ 4 mm²) 1x 6…50 mm²
Stranded (≥ 6 mm²) 2x 6…25 mm²
Flexible with ferrule 1x 6…35 mm²
2x 6…16 mm²
Bars or lugs L< –
l L
l< –
Connection capacity acc. to UL / CSA 1 or 2 x AWG 8…1
Tightening torque Recommended 4.00 Nm / 35 lb.in
Max. 4.50 Nm
Auxiliary conductors
(coil terminals)
Rigid solid 1x 1…4 mm²
2x 1…4 mm²
Flexible with ferrule 1x 1…2.5 mm²
2x 0.75…2.5 mm²
Lugs L< 8 mm
l L
l< 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18…14
Tightening torque Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP10
Coil terminals IP20
Screw terminals Delivered in open position, screws of unused terminals must be tightened
Main terminals M6
Screwdriver type Flat Ø 6.5 / Pozidriv 2
Coil terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2

1SBC101887S0201

ABB | 3/43
A9 ... A75 4-pole contactors
Terminal marking and positioning

A9 ... A75 contactors - AC operated


Standard devices without addition of auxiliary contacts
A1 A2 A1 A2
1L1 3L2 5L3 7L4 1 R3 R5 7

A1 1L1 3L2 5L3 7L4 A1 1 R3 R5 7

3 2T1 4T2 6T3 8T4 2 R4 R6 8


A2 A2 A2 2T1 4T2 6T3 8T4 A2 2 R4 R6 8

A9 ... A75-40-00 A9 ... A75-22-00 A9 ... A75-40-00 A9 ... A75-22-00

1SBC101888S0201

3/44 | ABB
N 4-pole contactor relays
AC operated

Description
N contactor relays are used for switching auxiliary circuits and control circuits.
These contactor relays are of the block type design with:
1SBC573622F0301

–– 4 poles. Contactor relays have mechanically linked auxiliary contact elements


–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

N40E 3
Ordering details
Number of contacts Rated control circuit Type Order code Weight
voltage
Uc Pkg
(1) (1 pce)
V 50 Hz V 60 Hz kg
24 24 N22E 1SBH141001R8122 0.340
48 48 N22E 1SBH141001R8322 0.340
A1 13
NO
21
NC
31
NC
43
NO 110 110…120 N22E 1SBH141001R8422 0.340
220…230 230…240 N22E 1SBH141001R8022 0.340
A2
NO
14
NC
22
NC
32
NO
44 230…240 240…260 N22E 1SBH141001R8822 0.340
380…400 400…415 N22E 1SBH141001R8522 0.340
400…415 415…440 N22E 1SBH141001R8622 0.340
24 24 N31E 1SBH141001R8131 0.340
48 48 N31E 1SBH141001R8331 0.340
A1 13
NO
21
NC
33
NO
43
NO 110 110…120 N31E 1SBH141001R8431 0.340
220…230 230…240 N31E 1SBH141001R8031 0.340
A2
NO
14
NC
22
NO
34
NO
44 230…240 240…260 N31E 1SBH141001R8831 0.340
380…400 400…415 N31E 1SBH141001R8531 0.340
400…415 415…440 N31E 1SBH141001R8631 0.340
24 24 N40E 1SBH141001R8140 0.340
48 48 N40E 1SBH141001R8340 0.340
A1 13
NO
23
NO
33
NO
43
NO
110 110…120 N40E 1SBH141001R8440 0.340
220…230 230…240 N40E 1SBH141001R8040 0.340
A2
NO
14
NO
24
NO
34
NO
44 230…240 240…260 N40E 1SBH141001R8840 0.340
380…400 400…415 N40E 1SBH141001R8540 0.340
400…415 415…440 N40E 1SBH141001R8640 0.340
(1) Other control voltages see voltage code table.

Main dimensions mm, inches


74 2.91"

68 2.68"
5.5 0.22"
35 mm EN/IEC 60715
74 2.91"

1SBC101858S0201

44 1.73" 4
0.16"
N22E, N31E, N40E

ABB | 3/45
N 4-pole contactor relays
Main accessories

Contactor and main accessories (other accessories available)

RV5, RC5
Surge suppressor

3
N contactor relay

A2
A1

TEF5
Electronic timer

BX4-CA
Protective cover

CAL
2-pole auxiliary CA5
contact block 4-pole auxiliary
contact block

CA5
1-pole auxiliary
contact block

Main accessory fitting details


Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor Main Front-mounted accessories Side-mounted accessories
types poles Auxiliary contact blocks Electronic timer Auxiliary contact blocks

1-pole CA5 4-pole CA5 TEF5 2-pole CAL5-11


N 2 2 E (1) 1 to 4 x CA5 or 1 x CA5 (4-pole) or 1 x TEF5 + 1 to 2 x CAL5-11
3 1 E (1)
4 0 E
(1) 2 N.C. front mounted auxiliary contacts maximum in mounting position 5.
1SBC101889S0201

3/46 | ABB
N 4-pole contactor relays
Main accessories

Ordering details (1)


1SBC580992F0301

For contactors Auxiliary Type Order code Pkg Weight


contacts qty (1 pce)

CA5-10 kg

Front-mounted instantaneous auxiliary contact blocks


4-pole N 1 – CA5-10 1SBN010010R1010 10 0.014
3
1SBC573752F0301

– 1 CA5-01 1SBN010010R1001 10 0.014


2 2 CA5-22N 1SBN010040R1222 2 0.060

Side-mounted instantaneous auxiliary contact block


N 1 1 CAL5-11 1SBN010020R1011 2 0.050
CAL5-11

For contactors Time delay Delay Auxiliary Type Order code Pkg Weight
range type contacts qty (1 pce)
selected by
switch
kg

Electronic timers
4-pole N 0.1...1 s ON-delay 1 1 TEF5-ON 1SBN020312R1000 1 0.065
1...10 s
10...100 s OFF-delay 1 1 TEF5-OFF 1SBN020314R1000 1 0.065
1SBC101396F0014

Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.

For contactors Rated control circuit Type Order code Pkg Weight
TEF5-OFF
voltage qty (1 pce)
Uc
V AC DC kg
1SBC574001F0301

Surge suppressors
N 24...50 ● ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● ● RV5/250 1SBN050010R1002 2 0.015
250...440 ● ● RV5/440 1SBN050010R1003 2 0.015
RV5/50
N 24...50 ● – RC5-1/50 1SBN050100R1000 2 0.012
50...133 ● – RC5-1/133 1SBN050100R1001 2 0.012
110...250 ● – RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● – RC5-1/440 1SBN050100R1003 2 0.012
(1) See "Main accessory fitting details" table.

1SBC101890S0201

ABB | 3/47
N contactor relays
Technical data

Contact utilization characteristics according to IEC


Contactor relay types AC operated N
Standards IEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1
Rated operational voltage Ue max. 690 V
Rated frequency (without derating) 50 / 60 Hz
Conventional free-air thermal current Ith θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
3 230-240 V 50/60 Hz 4A
400-415 V 50/60 Hz 3A
500 V 50/60 Hz 2A
690 V 50/60 Hz 2A
Rated making capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Rated breaking capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 6 A / 144 W
48 V DC 2.8 A / 134 W
72 V DC 1 A / 72 W
110 V DC 0.55 A / 60 W
125 V DC 0.55 A / 69 W
220 V DC 0.30 A / 66 W
250 V DC 0.30 A / 75 W
Short-circuit protection device for contactors
Ue ≤ 500 V AC - gG type fuse 10 A
Rated short-time withstand current Icw
at 40 °C ambient temperature, 100 A
for 1.0 s
in free air from a cold state 140 A
for 0.1 s
Minimum switching capacity 17 V / 5 mA
with failure rate acc. to IEC 60947-5-4 10-6
Non-overlapping time between N.O. and N.C. contacts ≥ 2 ms
Power dissipation per pole at 6 A 0.1 W
Max. electrical switching frequency AC-15 1200 cycles/h

Contact utilization characteristics according to UL / CSA


Contactor relay types AC operated N
Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V AC
Pilot duty A600, Q300

General technical data


Contactor relay types AC operated N
Rated insulation voltage Ui
acc. to IEC 60947-5-1 690 V
acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. 8 kV
Ambient air temperature
Operation in free air -40...+70 °C
Storage -60...+80 °C
Climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum operating altitude (without derating) 3000 m
Mechanical durability
Number of operating cycles ≥ 20 millions operating cycles
Max. switching frequency 6000 cycles/h
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1 Shock direction 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
A 20 g
1SBC101868S0201

A A B1 B2 B1 5g
B2 15 g
C1 20 g
C2 C2 20 g

3/48 | ABB
N contactor relays
Technical data

Magnet system characteristics


Contactor relay types AC operated N
Coil operating limits AC supply at θ ≤ 55 °C 0.85...1.1 x Uc
acc. to IEC 60947-4-1 Please also refer to "Mounting characteristics and conditions for use"
AC control voltage 50/60 Hz
Rated control circuit voltage Uc at 50 Hz 24...690 V
at 60 Hz 24...690 V
Coil consumption Average pull-in value 50 Hz 70 VA
60 Hz 80 VA
50/60 Hz (1) 74 VA / 70 VA 3
Average holding value 50 Hz 8 VA / 2 W
60 Hz 8 VA / 2 W
50/60 Hz (1) 8 VA / 2 W
Drop-out voltage approx. 40...65 % of Uc
Operating time
Between coil energization and: N.O. contact closing 10...26 ms
N.C. contact opening 7...21 ms
Between coil de-energization and: N.O. contact opening 4...11 ms
N.C. contact closing 9...16 ms
(1) 50/60 Hz coils: see "Coil voltage code table".

Mounting characteristics and conditions for use


Contactor relay types AC operated N
Mounting positions Pos. 2 +30° -30°

Pos. 4
Pos. 3

Pos. 1 Pos. 1 ± 30° Pos. 5 Pos. 6

Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for contactor relays
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc
positions at θ ≤ 70 °C Uc
6 at θ ≤ 55 °C 0.95…1.1 x Uc
> 55 °C unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
By screws (not supplied) 2 x M4 screws placed diagonally

Connecting characteristics
Contactor relay types AC operated N
Main terminals

Screw terminals with cable clamp


Connection capacity (min. ... max.)
Main conductors (poles)
Rigid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Bars or lugs Pole terminals L< 7.7 mm
l L
l< 3.7 mm
Coil terminals L< 8 mm
l< 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18…14
Tightening torque Recommended 1 Nm / 9 Ib.in
Max. 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals IP20
1SBC101869S0201

Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2

ABB | 3/49
N 4-pole contactor relays
Terminal marking and positioning

N contactor relays - AC operated


Standard devices without addition of auxiliary contacts
A1 13 21 31 43 A1 13 21 33 43
NO NC NC NO NO NC NO NO

A1 A2 A1 A2 A1 A2
13 21 31 43 13 21 33 43 13 23 33 43
NO NC NC NO NO NC NO NO
A2 14 22 32 44 A2 14 22 34 44
NO NC NC NO NO NC NO NO NO NO NO NO
N22E N31E

3 A1 13
NO
23
NO
33
NO
43
NO
NO NC NC NO NO NC NO NO NO NO NO NO

14 22 32 44 14 22 34 44 14 24 34 44
A2 A2 A2 NO NO NO NO
A2 14 24 34 44

N22E N31E N40E N40E

Other possible contact combinations with auxiliary contacts added by the user
A1 13 21 33 43 53
NO NC NO NO NO
A1 A2 A1 A2 A1 A2 A1 A2
13 21 33 43 13 21 33 43 13 23 33 43 13 23 33 43

NO NC NO NO NO NC NO NO NO NO NO NO NO NO NO NO NO NC NO NO NO
A2 14 22 34 44 54

53 5- -3 51 61 5- 6- -1 -1 Combination 41E
NO = + NO NC NC = + NC + NC
54 5- -4 52 62 5- 6- -2 -2

NO NC NO NO NO NC NO NO NO NO NO NO NO NO NO NO A1 13 23 33 43 51 61
NO NO NO NO NC NC
14 22 34 44 14 22 34 44 14 24 34 44 14 24 34 44
A2 A2 A2 A2
NO NO NO NO NC NC
A2 14 24 34 44 52 62
Combination 41E = N31E + CA5-10 Combination 42E = N40E + CA5-01 + CA5-01
Combination 42E

A1 13 23 33 43 53
NO NO NO NO NO
A1 A2 A1 A2 A1 A2 A1 A2
13 23 33 43 13 23 33 43 13 23 33 43 13 23 33 43

NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
A2 14 24 34 44 54

53 5- -3 53 63 5- 6- -3 -3 Combination 50E
NO = + NO NO NO = + NO + NO
54 5- -4 54 64 5- 6- -4 -4

NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO A1 13 23 33 43 53 63
NO NO NO NO NO NO
14 24 34 44 14 24 34 44 14 24 34 44 14 24 34 44
A2 A2 A2 A2
NO NO NO NO NO NO
A2 14 24 34 44 54 64
Combination 50E = N40E + CA5-10 Combination 60E = N40E + CA5-10 + CA5-10
Combination 60E
1SBC101870S0201

3/50 | ABB
Notes

N2

ABB | 3/51
Auxiliary contact blocks

Description
1SBC580992F0301

The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard
industrial environments.
Types of auxiliary contact blocks for front mounting:
–– CA5 1 or 4-pole block, instantaneous with N.O., N.C. contacts
CA5-10
–– CC5 1-pole block, with N.O. leading contact or N.C. lagging contact.
Select the 4-pole auxiliary contact blocks CA5 type, according to the contactor type for compliance with the
3 standard requirements (see "Terminal marking and positioning").
Types of auxiliary contact blocks for side mounting:
–– CAL 2-pole block instantaneous N.O. + N.C. contacts.
For clipping onto the right- and/or left-hand side of the contactors.
1SBC573794F0302

The CAL18-11B is a second block for mounting in addition to a first CAL18-11 block, right- and/or left-hand
of the A145 ... A300 contactors.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
CA5-40E

Ordering details (1)


For contactors Auxiliary contacts Type Order code Pkg Weight
qty (1 pce)

kg

Front-mounted instantaneous auxiliary contact blocks, 1-pole


A9 ... A110 1 0 – – CA5-10 1SBN010010R1010 10 0.014
N 4-pole 0 1 – – CA5-01 1SBN010010R1001 10 0.014
– – 1 0 CC5-10 1SBN010011R1010 10 0.014
1SBC573752F0301

– – 0 1 CC5-01 1SBN010011R1001 10 0.014

Front-mounted instantaneous auxiliary contact blocks, 4-pole


A9 ... A26-40-00 2 2 – – CA5-22E 1SBN010040R1022 2 0.060
CAL5-11 A9 ... A26-22-00 3 1 – – CA5-31E 1SBN010040R1031 2 0.060
A45 ... A110 4 0 – – CA5-40E 1SBN010040R1040 2 0.060
0 4 – – CA5-04E 1SBN010040R1004 2 0.060
1 1 1 1 CA5-11/11E 1SBN010040R1018 2 0.060
A9 ... A40-30-10 2 2 – – CA5-22M 1SBN010040R1122 2 0.060
3 1 – – CA5-31M 1SBN010040R1131 2 0.060
1 3 – – CA5-13M 1SBN010040R1113 2 0.060
0 4 – – CA5-04M 1SBN010040R1104 2 0.060
1 1 1 1 CA5-11/11M 1SBN010040R1118 2 0.060
A9 ... A40-30-01 2 2 – – CA5-22U 1SBN010040R1322 2 0.060
3 1 – – CA5-31U 1SBN010040R1331 2 0.060
4 0 – – CA5-40U 1SBN010040R1340 2 0.060
1SFC101033F0201

0 4 – – CA5-04U 1SBN010040R1304 2 0.060


N 4-pole 2 2 – – CA5-22N 1SBN010040R1222 2 0.060
3 1 – – CA5-31N 1SBN010040R1231 2 0.060
CAL18-11 1 3 – – CA5-13N 1SBN010040R1213 2 0.060
0 4 – – CA5-04N 1SBN010040R1204 2 0.060
4 0 – – CA5-40N 1SBN010040R1240 2 0.060

Side-mounted instantaneous auxiliary contact blocks, 2-pole


A9 ... A75 1 1 – – CAL5-11 1SBN010020R1011 2 0.050
N
A9 ... A16 – – 1 1 CCL5-11 1SBN011421R1008 2 0.050
N
A95 ... A300 1 1 – – CAL18-11 1SFN010720R1011 2 0.050
A145 ... A300 (2) 1 1 – – CAL18-11B 1SFN010720R3311 2 0.050
(1) For each contactor type, refer to "Accessory fitting details" table.
(2) 2 blocks CAL18-11 + 2 blocks CAL18-11B.
1SBC101891S0201

3/52 | ABB
Auxiliary contact blocks

Technical data
Front mounted Side mounted
Types 1-pole CA5, 1-pole CC5, CAL5-11, CCL5-11 CAL18-11, CAL18-11B
4-pole CA5

Contact utilization characteristics according to IEC


Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui 3
acc. to IEC 60947-5-1 690 V
Rated operational voltage Ue max. 24...690 V AC
Conventional thermal current Ith - θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
380-440 V 50/60 Hz 3A
500-690 V 50/60 Hz 2A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 6 A / 144 W
48 V DC 2.8 A / 134 W
72 V DC 1 A / 72 W
110 V DC 0.55 A / 60 W
125 V DC 0.55 A / 69 W
220 V DC 0.3 A / 66 W
250 V DC 0.3 A / 75 W
Short-circuit protection device gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
θ = 40 °C for 0.1 s 140 A
Minimum switching capacity
A40 … A75 contactors 17 V / 1 mA –
with failure rate acc. to IEC 60947-5-4 ≤ 10-7 –
A95 … A110 contactors 24 V / 50 mA – 24 V / 50 mA (0.5 million of operating cycles)
with failure rate acc. to IEC 60947-5-4 – – ≤ 10-6
Power dissipation per pole at 6 A 0.1 W 0.15 W
Mechanical durability
Number of operating cycles 10 millions (A9 … A75) 10 millions 5 millions (A95 ... A185)
3 millions (A95 … A110) 3 millions (A210 ... A300)
Max. switching frequency 3600 cycles/h
Electrical durability
Number of operating cycles see "Electrical durability" curves
Max. switching frequency AC-15 1200 cycles/h
DC-13 900 cycles/h

Contact utilization characteristics according to UL / CSA


Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V AC, 250 V DC
Pilot duty A600, Q300
AC thermal rated current 10 A

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1...4 mm²
1x
1...4 mm²
2x
Flexible with ferrule 0.75...2.5 mm²
1x
0.75...2.5 mm²
2x
l L Lugs 7.7 mm
L≤ 8 mm
3.7 mm
l> 3.7 mm
Connection capacity acc. to UL / CSA AWG 18...14
1 or 2 x
Tightening torque 1 Nm / 9 lb.in
Degree of protection Terminals IP20
1SBC101892S0201

acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529


Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2

ABB | 3/53
Add-on auxiliary contacts
Terminal marking and positioning

1-pole auxiliary contacts


-1 -3

NC NO

-2 -4

CA5-01 CA5-10

-5 -7

3 NC NO

-6 -8

CC5-01 CC5-10

2-pole auxiliary contacts


13X / 21X / 31X / 43X / 53X / 61X / 71X / 83X /
44X 32X 22X 14X 84X 72X 62X 54X

NO NC NC NO NO NC NC NO

14X / 22X / 32X / 44X / 54X / 62X / 72X / 84X /


43X 31X 21X 13X 83X 71X 61X 53X

CAL5-11, CAL18-11 CAL5-11, CAL18-11 CAL18-11B CAL18-11B


(L. h. s. mounted) (R. h. s. mounted) (L. h. s. mounted) (R. h. s. mounted)

17X / 25X / 35X / 47X /


48X 36X 26X 18X

NO NC NC NO

18X / 26X / 36X / 48X /


47X 35X 25X 17X

CCL5-11 CCL5-11
(L. h. s. mounted) (R. h. s. mounted)

4-pole auxiliary contacts


11 21 31 41 21 31 41 51 1 1 1 1 51 61 71 81

NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC

12 22 32 42 22 32 42 52 2 2 2 2 52 62 72 82

CA5-04E CA5-04M CA5-04U CA5-04N

13 21 31 43 21 31 43 53 3 1 1 3 53 61 71 83

NO NC NC NO NC NC NO NO NO NC NC NO NO NC NC NO

14 22 32 44 22 32 44 54 4 2 2 4 54 62 72 84

CA5-22E CA5-22M CA5-22U CA5-22N

13 21 33 43 21 33 43 53 3 1 3 3 51 63 73 83

NO NC NO NO NC NO NO NO NO NC NO NO NC NO NO NO

14 22 34 44 22 34 44 54 4 2 4 4 52 64 74 84

CA5-31E CA5-31M CA5-31U CA5-31N

13 23 33 43 21 31 41 53 3 3 3 3 53 63 73 83

NO NO NO NO NC NC NC NO NO NO NO NO NO NO NO NO

14 24 34 44 22 32 42 54 4 4 4 4 54 64 74 84

CA5-40E CA5-13M CA5-40U CA5-40N


1SBC101893S0201

13 21 35 47 21 33 45 57 53 61 71 81

NO NC NC NO NC NO NC NO NO NC NC NC

14 22 36 48 22 34 46 58 54 62 72 82

CA5-11/11E CA5-11/11M CA5-13N

3/54 | ABB
Electronic timers

Description
TEF5 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFF-
delay versions.
Compact solution in cabinet compared to separate timers
TEF5 electronic timers are front-mounted and locked on A contactors or N contactor relays.
A mechanical indicator allows to show the state of the contactor.
1SBC101396F0014

TEF5 electronic timers are supplied by direct wiring to the coil terminals A1 - A2 of the contactor or contac-
tor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil. 3
Available for a wide control voltage range 24...240 V AC / DC
TEF5-ON or TEF5-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently
TEF5-OFF of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted
by means of a rotary switch. The timing function is activated by closing or opening the device on which the
timer is mounted. The OFF-delay version operates without additional control supply.

Ordering details
For contactors, Time delay Delay Rated control Auxiliary Type Order code Weight
contactor relays range type circuit voltage contacts
selected by Uc Pkg
switch (1 pce)
V 50/60 Hz or DC kg
A9 ... A75 0.1...1 s ON-delay 24...240 1 1 TEF5-ON 1SBN020312R1000 0.065
N 1...10 s
10...100 s OFF-delay 24...240 1 1 TEF5-OFF 1SBN020314R1000 0.065

1SBC101894S0201

ABB | 3/55
Electronic timers
Technical data

Contact utilization characteristics according to IEC


Types TEF5-ON TEF5-OFF
Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui
acc. to IEC 60947-5-1 400 V
Rated impulse withstand voltage Uimp 4 kV
Rated operational voltage Ue max. 240 V
Rated frequency (without derating) 50 / 60 Hz
Conventional thermal current Ith - θ ≤ 40 °C 5A
3 Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 3A
220-240 V 50/60 Hz 1.5 A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 1 A / 24 W
Short-circuit protection device gG type fuse 6A
Rated short-time withstand current Icw for 1.0 s 8 A
θ = 40 °C for 0.1 s 8 A
Minimum switching capacity 12 V / 3 mA
with failure rate acc. to IEC 60947-5-4 24 V DC 10-7
Power dissipation per pole at 3 A 0.1 W
Function diagram ON-delay OFF-delay
150 ms 1s
min. min.
Uc (A1 - A2) Uc (A1 - A2)
100 ms 100 ms
min. min.
N.O. (67 - 68) N.O. (67 - 68)

N.C. (55 - 56) N.C. (55 - 56)

t t

Bistable relay inside.


Before use, once apply Uc then switch it off in order to initialize position of the contacts.
Control circuit voltage
AC control voltage Rated control circuit voltage Uc 24...240 V AC
50/60 Hz Average consumption 1.5 mA RMS 1 mA RMS
DC control voltage Rated control circuit voltage Uc 24...240 V DC
Average consumption 1.5 mA 1 mA
Rated frequency limits 50 / 60 Hz
Supply voltage range 0.85...1.1 x Uc (at θ ≤ 70 °C)
Overvoltage protection Varistor included
Time delay range (t) selected by switch 0.1...1 s
1...10 s
10...100 s
On-load reiteration accuracy under constant conditions ≤1%
Minimum ON period 0.1 s 1s
Recovery time 0.15 s 0.1 s
Ambient air temperature Operation -25 °C ... +70 °C
Storage -40 °C ... +80 °C
Climatic withstand Category B according to IEC 60947-1 Annex Q
Maximum operating altitude 2000 m
Mounting positions Acc. to mounting positions permitted on contactors or contactor relays
Shock withstand 1/2 sinusoidal shock for 11 ms: no change in contact position
acc. to IEC 60068-2-27 and EN 60068-2-27 Same as contactor or contactor relay
(Mounting position 1)
Mechanical durability
Number of operating cycles 5 millions operating cycles
Max. switching frequency 3600 cycles/h 1800 cycles/h
Max. electrical switching frequency
AC-15 1200 cycles/h
DC-13 900 cycles/h
1SBC101674S0201

3/56 | ABB
Electronic timers
Technical data

Contact utilization characteristics according to UL / CSA


Types TEF5-ON TEF5-OFF
Standards UL 508, CSA C22.2 N°14
Rated insulation voltage Ui
acc. to UL / CSA 300 V
Max. operational voltage 240 V
Pilot duty B300, R300
AC thermal rated current 5A
AC maximum volt-ampere making 3600 VA
AC maximum volt-ampere breaking 360 VA
3
DC thermal rated current 1A
DC maximum volt-ampere making-breaking 28 VA

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...2.5 mm²
2x 1...2.5 mm²
Flexible with non insulated ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Flexible with insulated ferrule 1x 0.75...2.5 mm²
2x 0.75...1.5 mm²
Lugs L≤ 8 mm
l L
l> 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18...14
Stripping length 10 mm
Tightening torque 1 N.m / 9 lb.in
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
Screw terminals Delivered in open position, screws of unused terminals should be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Terminal Marking 55 NC 67 NO 55 NC 67 NO
A1 A1

KM1 KM1

A2 A2
56 NC 68 NO 56 NC 68 NO

1SBC101674S0201

ABB | 3/57
Mechanical and electrical interlock units

Description
When mounted between two contactors, the mechanical interlock unit prevents one of the contactors from
closing as long as the other contactor is closed.
–– VM interlock units for mechanical interlocking of two horizontal or vertical mounted AC or DC operated
1SBC580411F0301

contactors
–– VE interlock units for mechanical and electrical interlocking of two horizontal mounted AC or DC operated
contactors.

3 VM300H
Ordering details (1)
Left side Right side Mounting Type Order code Pkg Weight
contactor contactor qty (1 pce)
kg

Mechanical interlock units for two horizontal mounted contactors (2)


A9 ... A40 A9 ... A40 Rail mounting or VM5-1 1SBN030100R1000 1 0.066
mounting plate to be
ordered separately (3)
A9 ... A40 A45 … A110 See table below with – – – –
A45 … A75 A45 … A110 VE5 type – – – –
1SBC580411F0301

A95 … A185 A45 … A110 – – – –


A95 … A185 A145 … A300 Additional plate VM300H 1SFN034700R1000 1 0.150
A210 … A300 A145 … A300 (not supplied) VM300H 1SFN034700R1000 1 0.150

VM300V

Up contactor Down contactor Mounting Type Order code Pkg Weight


qty (1 pce)
kg

Mechanical interlock units for two vertical mounted contactors (4)


A95 … A185 A145 … A300 Additional plate VM300V 1SFN034701R1000 1 0.150
A210 … A300 A145 … A300 (not supplied) VM300V 1SFN034701R1000 1 0.150
1SBC572822F0301

Left side Right side Mounting Type Order code Pkg Weight
contactor contactor qty (1 pce)
kg

Mechanical and electrical interlock units for two horizontal mounted contactors
VE5-1 A9 ... A40 A9 ... A40 Rail mounting or VE5-1 1SBN030110R1000 1 0.076
A30 … A75 A45 … A75 mounting plate to be VE5-2 1SBN030210R1000 1 0.146
A45 ... A75 A30 ... A75 ordered separately (3) VE5-2 1SBN030210R1000 1 0.146
A45 … A75 A95 … A110 Additional plate VE5-2 (5) 1SBN030210R1000 1 0.146
A95 … A110 A45 … A75 (not supplied) VE5-2 (5) 1SBN030210R1000 1 0.146
A95 … A110 A95 … A110 VE5-2 1SBN030210R1000 1 0.146
(1) For each contactor type, refer to "Accessory fitting details".
(2) Mechanical durability: VM5-1 = 5 millions cycles, VM300H = 1 million cycles.
(3) Rail mounting for: 2 x A9 ... A40 contactors only
2 x A30, A40 contactors + MMS.
PM26-23 mounting plate for: 2 x A9 ... A26 contactors + MMS.
(4) Mechanical durability: VM300V = 1 million cycles.
(5) The combination of A45 ... A75 contactors interlocked with A95, A110 contactors cannot be mounted on symmetrical rail
(75 mm, IEC/EN 60715).
1SBC101895S0201

3/58 | ABB
Mechanical and electrical interlock units

Technical data
Types VE5-1 VE5-2

Contact utilization characteristics according to IEC


Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui
acc. to IEC 60947-5-1
Rated operational voltage Ue max.
690 V
24...690 V
3
Conventional thermal current Ith - θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
380-440 V 50/60 Hz 3A
500-690 V 50/60 Hz 2A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 6A
48 V DC 2.8 A
72 V DC 1A
125 V DC 0.55 A
250 V DC 0.3 A
Short-circuit protection device - gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
θ = 40 °C for 0.1 s 140 A
Power dissipation per pole at 6 A 0.15 W
Mechanical durability
Number of operating cycles 5 millions operating cycles
Max. switching frequency 600 cycles/h

Utilization characteristics according to UL / CSA


Standards UL 508, CSA C22.2 N°14
Max. operational voltage 600 V

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 8 mm
l L
l> 3.5 mm
Tightening torque Recommended 1 Nm
Max. 1.2 Nm
Degree of protection IP20
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Terminal marking 01 01
NC NC
E0085D1

02 02
Technical note: when, during switching, the arc time is estimated to more than 40 ms, the closing signal of one of the two contactors must be delayed with respect to the opening
signal of the other contactor in order to prevent a short-circuit.
Use a TEF5 or TE5S electronic timer according to application use with time lapse for A contators.
1SBC101896S0201

ABB | 3/59
Electronic timer for star-delta starters

Description
When used in star-delta starters, the TE5S lags the star connection and provides a lapse of 50 ms before
the switch over to delta connection.
According to the type of device chosen, the electronic circuit has a 24 V AC / DC, 110 to 120 V AC,
1SBC575582F0302

220 to 240 V AC or 380 to 440 V AC supply. An output relay with reversing contact ensures high current
switching. A two-position switch allows selection of one of the two time delay ranges: 0.8 to 8 s or 6 to
60 s. The 0.1 to 1.0 graduated button allows an initial setting without steps within the previously selected
range which can then be adjusted using a chronometer.
3 Note: We recommend that you allow for temperature drift for the final adjustment of the time delay setting.
Drift: -0.2 % per °C.
TE5S...
For example, a setting made at 20 °C will yield a time delay shorter by 7 % at 55 °C in a c­ ubicle (-0.2 %
per °C i.e. -0.2 x 35 = -7 %).
Regardless of these settings the TE5S provides a fixed "lapse" of 50 ms between the opening of contact
15-16 and the closing of contact 15-18. This time delay prevents from arc short-circuit during star to delta
switching.
Operation
On energization, the green U indicator light (voltage applied) comes on. Contact 15-16 then immediately
U
moves to the closed position.
15-16 Count-down of the programmed time immediately commences. When the time delay has elapsed, contact
15-16 opens and at the same time the 50 ms lapse, t2, begins after which contact 15-18 moves to the
E0719D1

R
15-18 closed position. The yellow R indicator light comes on.
t1 t2 (t2 = 50ms) On de-energization, the U and R indicator lights go out and, after the 250 ms resetting time, the device is
ready for a new cycle.
Chart
Mounting
On 35 x 7.5 mm or 35 x 15 mm mounting rail according to IEC/EN 60715.

Ordering details
A1
15

For contactors Rated control circuit Type Order code Pkg Weight
t1 t1+t2
voltage qty (1 pce)
Uc
E0718D
A2
16

18

V 50/60 Hz V DC kg
A9 ... A300 24 24 TE5S-24 1SBN020010R1001 1 0.080
Equivalent diagram 110...120 – TE5S-120 1SBN020010R1002 1 0.080
220...240 – TE5S-240 1SBN020010R1003 1 0.080
380...440 – TE5S-440 1SBN020010R1004 1 0.080

A1 15
A1 15

TE5S
U
Uc=
0.5

x 0.1

1.0

8s t1 60s

R
Star-Delta Timer Main dimensions mm, inches
75 2.95"
E0720D1

23 0.91" 65 2.56"
16 18 A2

16 18 A2

Front face
35 mm EN/IEC 60715
85 3.35"

45 1.77"

1SBC101523S0201

3/60 | ABB
Electronic timer for star-delta starters

Technical data
Types TE5S-24 TE5S-120 TE5S-240 TE5S-440

Utilization characteristics according to IEC


Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui
acc. to IEC 60947-5-1 440 V
Rated operational voltage Ue max. 24 V DC –
24…240 V AC 440 V AC 3
Conventional free air thermal current Ith 10 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-120 V 50/60 Hz 5A –
220-240 V 50/60 Hz 4A –
380-440 V 50/60 Hz – 3A
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 4A –
Short-circuit protection device - gG type fuse 10 A
Control circuit voltage
AC control voltage Rated supply voltage Uc 24 V AC 110…120 V AC 220…240 V AC 380…440 V AC
50/60 Hz Average consumption 1.5 VA 3.5 VA 6.5 VA 12.5 VA
DC control voltage Rated supply voltage Uc 24 V DC – – –
Average consumption 0.7 W – – –
Rated frequency limits 48…63 Hz
Supply voltage range 0.85…1.1 x Uc
Overvoltage protection Built-in varistor
Load factor 100 %
Time delay range (t1) selected by switch 0.8…8 s and 6…60 s
Temperature drift -0.2 % per °C
Mechanical setting accuracy ±15 % of the setting range
On-load reiteration accuracy under constant conditions ±2 % after 1 million operating cycles
Minimum time lapse (t2) 50 ms
Minimum time lapse after 1 million of operating cycles 40 ms
Resetting time (max.) 250 ms
Front panel display green indicator light Energization
yellow indicator light Output relay activated
Ambient air temperature
Operation -25…+60 °C
Storage -40…+85 °C
Shock withstand
acc. to IEC 60068-2-27 and EN 6006-2-27
C

A A B B Shock direction
A 20 g / 11 ms
15 g / 11 ms
E0863D

B
C C 20 g / 11 ms
Vibration withstand 10 to 300 Hz in the 3 directions
acc. to IEC 60068-2-6 and EN 60068-2-6 3g
Mechanical durability 5 millions operating cycles
Electrical durability 1 million operating cycles
On-load maximum switching frequency 720 cycles/h 600 cycles/h
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...2.5 mm²
2x 1...2.5 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Tightening torque Recommended 0.6 Nm
Max. 0.8 Nm
1SBC101326S0201 - Rev. A

Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M2.5
Screwdriver type Flat Ø 4 / Pozidriv 1

ABB | 3/61
Surge suppressors for contactor coils

(V) Description
1000
The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.
T (µs)
0 100 The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of
1000 surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed
ranging from interference on the electronic devices to breakdown of insulators and even destruction of cer-
0 100
tain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V /
A 884D

50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
3 Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of
3500 V.
Overvoltage Factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value
Ûc of the coil rated control voltage Uc:

Ûs max. Ûs max. Ûs max.
1SBC574001F0301

k = in DC: k = or in AC: k =
Ûc Uc Uc√2

3500
RV5/50 For example the following is obtained for the above graph: k = ≈ 60
42 √2

To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppressors de-
signed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping
voltage frequencies.
Each case is different, but the technical data tolerances and the generous sizing of parts have enabled us to
reduce the number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
1SBC573891F0301

Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied
at its terminals.

RC5-1/50 Ordering details


For contactors Rated control circuit Type Order code Pkg Weight
voltage qty
Uc (1 pce)
V AC DC kg
A9 ... A110 24...50 ● ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● ● RV5/250 1SBN050010R1002 2 0.015
250...440 ● ● RV5/440 1SBN050010R1003 2 0.015
A9 ... A40 24...50 ● – RC5-1/50 1SBN050100R1000 2 0.012
50...133 ● – RC5-1/133 1SBN050100R1001 2 0.012
110...250 ● – RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● – RC5-1/440 1SBN050100R1003 2 0.012
A45 ... A110 24...50 ● – RC5-2/50 1SBN050200R1000 2 0.015
50...133 ● – RC5-2/133 1SBN050200R1001 2 0.015
110...250 ● – RC5-2/250 1SBN050200R1002 2 0.015
250...440 ● – RC5-2/440 1SBN050200R1003 2 0.015
A145 ... A300 250...440 ● – RC5-3/440 1SFN050300R1003 2 0.028
1SBC101899S0201

3/62 | ABB
Surge suppressors for contactor coils

Technical data
Varistor RV5/50 RV5/133 RV5/250 RV5/440
Rated control circuit voltage Uc 24...50 V AC 50...133 V AC 110...250 V AC 250...440 V AC
24...50 V DC 50...133 V DC 110...250 V DC 250...440 V DC
Residual overvoltage (clipping voltage) 132 V AC 270 V AC 480 V AC 825 V AC
132 V DC 270 V DC 480 V DC 825 V DC
Opening time growth factor 1.1...1.5
Operating temperature -20...+70 °C
Connection to the coil terminals (parallel mounting) Clip-on for both fixing and connection. 3
Fixing Clipped onto the top part of the contactor base without change in contactor overall dimensions.
Advantages High energy absorption: good damping - Unpolarized system.
Drawback Clipping as from Uvdr (1), thus voltage front up to this point.
(1) Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ±10 %.

RC type RC5-1/50 RC5-1/133 RC5-1/250 RC5-1/440


RC5-2/50 RC5-2/133 RC5-2/250 RC5-2/440
– – – RC5-3/440
Rated control circuit voltage Uc 24...50 V AC 50...133 V AC 110...250 V AC 250...440 V AC
Residual overvoltage (clipping voltage) 2 to 3 x Uc max.
Opening time growth factor 1.2...1.3
Operating temperature -20...+70 °C
Connection to the coil terminals (parallel mounting) Clip-on for both fixing and connection.
Fixing Clipped onto the top part of the contactor base without change in contactor overall dimensions.
Advantages Very fast clipping - Attenuation of steep fronts and thus of high frequencies. No operating delays.

Wiring diagrams
A1 A1

A2 A2
Varistor RC type

Dimensions
1SBC101900S0201

The add-on block does not increase the


contactor overall dimensions
RV5, RC5

ABB | 3/63
Interface relays

Description
1SBC101005F0014

RA5-1 interface relay is designed to receive 24 V DC signals delivered by PLC’s or other sources with a
low output power and to restore them with sufficient power to operate the coils of the relevant A9 ... A110
contactors.
RA5-1 interface relay is made up of a miniature electromechanical relay equipped with a N.O. contact and
with a low consumption 24 V DC coil.
The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power contactor.
RA5-1
3 Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators and,
more generally, on component lifetime. The RA5-1 is equipped with surge suppressors:
–– on the 24 V DC relay coil via a diode,
–– on the power contactor coil via a varistor.
Furthermore, the RA5-1 is protected against relay pole reversal by a diode inserted between the E1 and E2
input terminals.

Ordering details
For contactors Coil voltages Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V 50/60 Hz V DC kg
A9 ... A110 24...250 24 RA5-1 1SBN060300R1000 1 0.050
RA5-1 1SBN060300T1000 10 0.050

1SBC101901S0201

3/64 | ABB
Interface relays

Technical data
Type RA5-1

Utilization characteristics according to IEC


Standards IEC 60255-5
Rated insulation voltage Ui
acc. to IEC 60947-4-1 250 V AC
Ambient air temperature
In free air operation at Uc = 24 V DC (between E1 and E2) -25…+70 °C
from 0.85 to 1.1 x Uc -25…+55 °C 3
Storage -40…+70 °C
Climatic withstand Complies with that of associated contactors
Maximum operating altitude 3000 m
Mounting positions No limitation
Fixing Using the contactor A1 and A2 teminal connecting parts

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1...4 mm² 1x
1...4 mm² 2x
Flexible with ferrule 0.75...2.5 mm²
1x
0.75...2.5 mm²
2x
l L
Lugs 8 mm L<
3.5 mm l>
Tightening torque Recommended 1 Nm
Max. 1.2 Nm
Degree of protection Protection against direct contact in acc. with EN 50274
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 RA5-1 wired and mounted on the associated contactor
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2

Working data
Surge suppression
For contactor coil Varistor
For interface relay coil Diode
Protection against polarity reversal between terminals E1 and E2 Diode
Interface relay operating time Closing and drop-out ≤ 10 ms
Total operating time, interface relay + contactor
Between energization and: N.O. contact closing 20…37 ms
N.C. contact opening 17…32 ms
Between de-energization and: N.O. contact opening 17…25 ms
N.C. contact closing 20…28 ms

Electrical input data


Control voltage (E1 and E2 terminals) Uc
Rated value 24 V DC
Max. range at ambient temperature 20 °C 19…30 V DC
Max. consumption for Uc = 24 V DC, θ = 20 °C 0.3 W
"0" status (relay open) for Uc ≤ 2.4 V DC
for Ic < 1 mA
"1" status (relay closed) for Uc ≥ 19 V DC
Max. short supply interruption immunity time 2 ms

Electrical output data


Switching voltage (A0 and A2 terminals) ≤ 250 V AC
Electrical durability
Number of operating cycles 2 millions (600 cycles/h) on A9 ... A75 contactors or N contactor relays
0.5 million (600 cycles/h) on A95 and A110 contactors

Connection
PLC
The "E1+" and "E2-" input terminals must be connected, according to their polarity, to the PLC output.
Output The RA5-1 is equipped with two terminal pads for connection to the A1 and the A2 terminals of the
Uc
≤ 250 V AC

24 V DC
+ contactor coil.
This coil is supplied between the A0 and the A2 terminals of the RA 5-1.
A0 A2 E2 – E1 +
Mounting: terminals pads clamped inside the contactor coil terminals.
RA 5-1
1SBC101902S0201

A1
KM1
A2

ABB | 3/65
Mechanical latching units

Description
For converting standard contactors into latched contactors.
1SBC565483F0301

The WB75-A block contains a mechanical latching device with electromagnetic impulse unlatching (AC or
DC) or manual unlatching.
Captive screw type connecting terminals, built-in cable clamps, M3.5 (+,-) pozidriv 2 screw with screwdriver
guidance; delivered untightened and protected against accidental direct c
­ ontact.
WB75-A
Operation
3 After closing, the contactor continues to be held in the closed position by the latching mechanism should the
supply voltage fail at the contactor coil terminals.
Contactor opening can be controlled:
–– electrically by an impulse (AC or DC) on the WB75-A block coil.
(the coil is not designed to be permanently energized)
–– manually by pressing the pushbutton on the front face of the WB75-A block.
Mounting
E1 E2 The WB75-A block is clipped onto the front face of the 1-stack contactor where it takes up two slots. The
two other slots may accept CA5... single pole auxiliary contacts (1 block on each side of the mechanical
Terminal marking latch).

Ordering details
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V 50 Hz
or DC V 60 Hz kg
A9 ... A75 24 24...28 WB75-A FPTN372726R1001 1 0.120
42 42...48 WB75-A FPTN372726R1002 1 0.120
48 48...55 WB75-A FPTN372726R1003 1 0.120
110 110...127 WB75-A FPTN372726R1004 1 0.120
220...230 220...255 WB75-A FPTN372726R1006 1 0.120
230...240 230...277 WB75-A FPTN372726R1005 1 0.120
380...415 380...440 WB75-A FPTN372726R1007 1 0.120
415...440 440...480 WB75-A FPTN372726R1008 1 0.120

1SBC101903S0201

3/66 | ABB
Mechanical latching units

Technical data
Type WB75-A

Utilization characteristics according to IEC


Rated insulation voltage Ui acc. to IEC 60947-1 690 V
Max. electrical impulse time
On AC coil (with load factor 5 %)
On DC coil (with load factor 3 %)
20 s
8s
3
Min. electrical impulse time
For latching (energizing of the contactor coil) AC 50 ms
For pull-out (energizing of the WB block coil) AC 30 ms
Coil operating limits AC or DC supply 0.85…1.1 x Uc
AC control voltage 50/60 Hz
Rated control circuit voltage Uc 24…480 V AC
Coil consumption Average pull-in value 90 VA
Average holding value 60 VA
DC control voltage
Rated control circuit voltage Uc 24…440 V DC
Coil consumption Average pull-in value 110 W
Average holding value 110 W
Operating time
On contactor closing (latching)
Between coil energization and:
N.O. contact closing No difference with the operation of a contactor without mechanical latching unit
N.C. contact opening No difference with the operation of a contactor without mechanical latching unit
On contactor opening (unlatching)
Between WB coil energization and:
N.O. contact opening 5…25 ms
N.C. contact closing 7…28 ms
Mechanical durability
Number of operating cycles 1 million operating cycles
Max. switching frequency 3600 cycles/h with on-load factor of 8 %

Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 8 mm
l L
l> 3.5 mm
Tightening torque Recommended 1 Nm
Max. 1.2 Nm
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101333S0201 - Rev. A

ABB | 3/67
Function markers
Impulse contact blocks

BA5-50 function markers


Description
Set of 50 function markers designed to be clipped onto the front face of devices. Details can be added to
these markers using a ball point pen, indelible felt-tip pen or pentel white.
Self-adhesive labels (not supplied) can also be added to them.
Marker dimensions: 7 x 19 mm (0.276" x 0.748").
1SBC575874F0301

3
Ordering details
BA5-50 For contactors Type Order code Pkg Weight
qty (1 pce)
kg
Contactors, thermal overload relays and accessories BA5-50 1SBN110000R1000 1 0.017

CB5 impulse contact blocks


Description
Impulse contact blocks are designed for use in enclosures, in association with an adjustable mechanical
pushbutton. Two types are available:
–– CB5-10: N.O. contact with a black actuator ("ON" function)
1SBC100039V0014

–– CB5-01: N.C. contact with a light grey actuator ("OFF" function).


These blocks are equipped with 2 connecting leads 0.5 mm2 with end, approximately 18 cm long.
Mounting: Clipped onto the front face of the contactors.
CB5

Ordering details
For contactors Contacts Type Order code Pkg Weight
qty (1 pce)

kg
A9 ... A110 1 – CB5-10 1SBN010013R1010 1 0.012
– 1 CB5-01 1SBN010013R1001 1 0.012

Main dimensions mm, inches


23.2 0.91" 10 0.39" 21.6 0.85" 5 0.2"
9.8 9.8
0.39" 0.39"
36 1.42"

36 1.42"

1SBC101898S0201

CB5-10 CB5-01

3/68 | ABB
Terminal shrouds, terminal enlargements, terminal extensions
Connector terminals

Terminal shrouds
Description
1SFT98099-019C3

Main terminal protection for A145 ... A300 contactors.


The auxiliary contact blocks and coils are designed to provide an IP20 degree of protection.
The main terminals, equipped with lugs or connectors, can be protected against accidental direct contact
LT...-AC after wiring (EN 50274) by the addition of terminal shrouds (see table below).

Ordering details 3
For contactors Type Order code Pkg Weight
qty (1 pce)
1SFT98099-125

kg
A145 ... A185 with connectors LT185-AC 1SFN124701R1000 2 0.050
A145 ... A185 with lugs LT185-AL 1SFN124703R1000 2 0.220
A145 ... A185 with short. bar LY185 LT185-AY 1SFN124704R1000 1 0.050
LT...-AL or between A145 and TA200DU
or between A185 and TA200DU
A210 ... A300 with connectors LT300-AC 1SFN125101R1000 2 0.070
A210 ... A300 with lugs LT300-AL 1SFN125103R1000 2 0.280
A210 ... A300 with short. bar LY300 LT300-AY 1SFN125104R1000 1 0.075
1SFT98000-014

LW... Terminal enlargements


LT...-AY Description
Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger
connections to be mounted.
1SFT98000-011C3

Sets containing 3 tin plated copper bars fixed by an isolating spacer.


Ordering details
For contactors Dimensions Type Order code Pkg Weight
LW... hole Ø bar qty (1 pce)
mm mm kg
A95, A110 6.5 15 x 3 LW110 1SFN074307R1000 1 0.100
A145, A185 10.5 20 x 5 LW185 1SFN074707R1000 1 0.250
1SFT98000-012C3

A210 ... A300 10.5 25 x 5 LW300 1SFN075107R1000 1 0.450

LX... LX... Terminal extension


Description
1SFT98099-00211C1

Extension pieces designed to extend the main terminals of contactors for combined mounting of
contactors and connection sets.
Sets containing 3 tin plated copper bars fixed by an isolating spacer.
Ordering details
LZ...
For contactors Dimensions Type Order code Pkg Weight
hole Ø bar qty (1 pce)
mm mm kg
A145, A185 8.5 20 x 5 LX185 1SFN074710R1000 1 0.250
1SFT98099-095C2

A210 ... A300 10.5 20 x 5 LX300 1SFN075110R1000 1 0.350

LZ... Connector terminals


Description
Connection of copper and aluminium cables to the terminal pads of the poles of A contactors.
Ordering details
1SBC580542F0302

Cables For contactors Cable cross section Type Order code Pkg Weight
qty (1 pce)
mm² kg
Single Cu A145, A185 6...185 – 1SDA023354R0001 3 0.200
LZ... A210 ... A300 16...240 – 1SDA023368R0001 3 0.400
Single Al & Cu A145, A185 35...95 – 1SDA023356R0001 3 0.100
1SFC101153C0201

A145, A185 25...150 – 1SDA023357R0001 3 0.100


A210 ... A300 120...240 – 1SDA023370R0001 3 0.200
Double Cu A145, A185 2 x (50...120) LZ185-2C/120 1SFN074709R1000 3 0.300
Double Al & Cu A210 ... A300 2 x (95...120) – 1SDA025766R0001 3 0.400

ABB | 3/69
Voltage code table

The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give
the order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the order code accord-
ing to the table below. Example: for contactor A50-30-00 and coil 48 V 50/60 Hz, the order code is 1SBL351001R8300.

A contactors
AC coil code
Auxiliary contacts Contactors: A
3 Type
N.O.  N.C.
Order code
50 Hz 60 Hz
81 24 V 24 V
A40 - 30 - 10 1SBL321001R 80 10 82 42 V 42 V
83 48 V 48 V
84 110 V 110...120 V
36 190 V 220 V
N.O.  N.C. 80 220...230 V 230...240 V
Main contacts
88 230...240 V 240...260 V
85 380...400 V 400...415 V
86 400...415 V 415...440 V
Contactor type
A AC operated
Codes in bold for dual frequency coils.

N contactor relays AC coil code


Contactors: A
50 Hz 60 Hz
Type Order code
81 24 V 24 V
N 40 E 1SBH141001R 80 40 82 42 V 42 V
83 48 V 48 V
84 110 V 110...120 V
36 190 V 220 V
N.O.  N.C. 80 220...230 V 230...240 V
Number contacts
88 230...240 V 240...260 V
85 380...400 V 400...415 V
86 400...415 V 415...440 V
Contactor type
N AC operated
Codes in bold for dual frequency coils.

1SBC101904S0201

3/70 | ABB