DV 206 Ro N1VC7V K

This document provides specifications for a PVC-insulated cable with a copper tape screen rated for 0.6/1 kV. The cable uses a copper conductor, PVC insulation and sheathing, and is flame retardant. It is intended for power supply in open or confined areas, underground, underwater, and more. Temperature ratings and physical characteristics like minimum bending radius are also listed.

Uploaded by

dorinmircea1959
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views2 pages

DV 206 Ro N1VC7V K

This document provides specifications for a PVC-insulated cable with a copper tape screen rated for 0.6/1 kV. The cable uses a copper conductor, PVC insulation and sheathing, and is flame retardant. It is intended for power supply in open or confined areas, underground, underwater, and more. Temperature ratings and physical characteristics like minimum bending radius are also listed.

Uploaded by

dorinmircea1959
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

N1VC7V-K 0.

6/1 kV

Cablu de semnalizare si control cu izolatie si manta de PVC, PVC-insulated and sheathed cable with copper
cu ecran din banda cupru , care nu favorizeaza arderea tape screen

Standard de fabricatie: DV 206 RO ; IEC 502-1 Standard: DV 206 RO ; IEC 502-1

Tensiune nominala Uo/U : 0.6/1 kV Rated voltage Uo/U : 0.6/1 kV

Domeniul de utilizare Applicability :


Cablurile sunt utilizate pentru transportul energiei Power supply to power stations.
electrice la statii de putere. The cables can be installed in open or confined areas,
Cablurile pot fi pozate in spatii inchise si deschise, in underground, in sewers, in concrete, under water
pamant ,in canale ,in beton ,in apa
Temperatura max in functionarea de durata :70 °C Max. temperature in long-run operation: 70 °C
Temperatura de utilizare normala este de -30°C÷+60°C Normal operational temperature range : -30°C÷+60°C
Temperatura minima de montaj este de +5°C Minimum temperature during installation : +5°C

Conductor de cupru Copper conductor :


Conductor multifilar SR EN 60228 ,Cl 5 Multiwire annealed copper conductor, SR EN 60228
,Cl 5
Izolatia
PVC tip R2 Insulation :
PVC type R2
Manta interna PVC
PVC inner sheath
Ecran
Ecran din banda de cupru de grosime 0.1 mm Screen
Rezistenta electrica : max 5 Ω/km Copper tape 0.1 mm thick
Max. resistance at 20°C Ω/km : max 5 Ω/km
Manta exterioara
PVC tip RZ Outer sheath
PVC type RZ
Cablurile sunt cu intarziere marita la propagarea flacarii
,incercare conf SR EN 332-3-24 cat C The cables are extra flame retardant ; test according to SR
EN 332-3-24 Cat C.
Raza minima de curbura la instalare :8*(D+d)
Min. bending radius at installation : 8*(D+d)
Forta maxima de tractiune la pozare
50 N/mm2 Max. tensile strain during installation :
50 N/mm2
Cod de culori conductoare izolate
J -g-v ,restul negre numerotate Color coding :
O - negre numerotate J-yellow-green and numbered conductors
O-numbered black conductors
N1VC7V-K 0.6/1 kV

Cablu de semnalizare si control cu izolatie si manta de PVC, PVC-insulated and sheathed cable with copper
cu ecran din banda cupru , care nu favorizeaza arderea tape screen

Tipodimensiun Diam Grosime Diametru Rezistenta Masa Curenti admisibili la pozare


e cablu max al radiala exterior electrica, Inf
Cable size sarmei max max la 20°C permissible currents during installation
izolatie manta
In aer pe In scurt- In scurt-circuit a
Max. perete circuit ecranului
max. copper Inf. resistance at In over- During During short-
wire diam insula- sheath outer 20°C Mass hed short-circuit circuit
tion, Ω/km
diameter inf Of sceen

kg/k A kA kA
mm mm
mm mm m
7x1.5 0.26 0.8 1.8 16.5 13.3 400 10 0.17 0.6
7x2.5 0.26 0.9 1.8 18.6 7.98 460 11 0.28 0.6
12x2.5 0.26 0.9 2.0 24.3 8.06 850 11 0.28 0.6
16X2.5 0.26 0.9 2.0 26.4 8.06 1050 11 0.28 0.6

I – Conductor flexibil din cupru recopt necositorit


II – IzolaŃie din policlorură de vinil calitate R2.
III – invelis intern extrudat .
IV- banda de cupru
V – Manta din policlorură de vinil calitate RZ .
VI – Marcaj format din -Tipul cablului
-Marcaj special pentru identificarea caracteristicilor de nepropagare a incendiului.
-Marcaj de recunoaştere a fabricantului,Marca de conformitate