Box D
Box D
General Description
The fan of the BOX-D series are particularly designed for air extraction, supply or filtration.
Their main characteristic is the low noise level which makes them ideal for urban environ-
ments (apartments, houses, bard restaurants, gymnasiums, offices) and industrial sites
where radiated noise is a problem. The low noise level is due to their plenum lined with
acoustic material, that allows a remarkable reduction of noise level, inevitably generated
by the fan. The blower consists of a double inlet forward curve centrifugal fan with built-in
motor.
Construction
• Profiless cabinet is manufactured in PPGI sheet with removable access panel to allow
easy access to fan and motor.
• The blower is fitted using suitable support feet and is completely isolated from the ca
sing by anti-vibration mounts and gaskets.
• Acoustic lining in self-extinguishing techno-polymer
• Double inlet blower, forward curved, with direct drive built-in asynchronous motor, sin
gle-phase or three-phase, particularly suitable for speed regulation (using the suitable
speed regulators shown in this catalogue).
• Flanged Inlet and outlet for easy Duct Work
Upon request
• Different discharge orientation
• Electronic and self-transformer speed regulators.
• Pre-filtered section
• Customised cabinet size
• Construction with the Aluminium extruded profile.
• Versions with double skin panels (20 mm thick) only in AL extruded profile.
• Blowers with EC motors are available on request. Performance of these blowers are not
certified by AMCA.
138
Dimensions BOX-D
Discharge angles
sez.
139
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
240/1/50Hz
Nominal RPM - 2240
Max Motor Input Power - 31 w
Box-D 3/4 B4M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
194 28 31 4 20/B 0.13 220-240/1/50 1628
Ps(Pa)
W(W)
RVN-RVS 46 60 56 52 48 41 38 36 33
Sound performance not licensed by AMCA
Q(m³/s)
0 36 72 108 144 180 216
Q(m3/hr)
sez.
5 240/1/50Hz
Nominal RPM - 2280
Max Motor Input Power - 198 w
Box-D 3/8 B4M
Max Nominal Max
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
727 190 198 4 44/B 0.84 240/1/50 1579
Ps(Pa)
W(W)
RVN-RVS 52 65 61 57 51 48 43 41 38
Q(m3/hr)
230/1/50Hz
Nominal RPM - 1320
Max Motor Input Power - 359 w
Box-D 7/7 B4M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
1667 147 359 4 32/F 1.70 240/1/50 1061
Ps(Pa)
W(W)
RV/1-RVM/2 52 85 84 77 68 61 54 52 48
Q(m³/s)
0 180 360 540 720 900 1080 2205 1440 1620 1800
Q(m3/hr)
140
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
230/1/50Hz
Nominal RPM - 925
Max Motor Input Power - 204 w
Box-D 7/7A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
1375 62 204 6 32/F 1.00 240/1/50 850
Ps(Pa)
W(W)
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw,dB)
at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K
RV/1-RVM 48 84 71 75 63 56 47 44 41
Q(m³/s)
Q(m3/hr)
sez.
5
230/1/50Hz
Nominal RPM - 1400
Max Motor Input Power - 910 w
Box-D 9/7 B4M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
2826 370 910 4 20/F 5.00 240/1/50 1265
Ps(Pa)
W(W)
RV/2-RVM3 58 94 85 83 73 69 63 61 55
Q(m³/s)
Q(m3/hr)
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
1886 147 326 6 20/F 1.90 240/1/50 849
Ps(Pa)
W(W)
RV/1-RVM/2 50 86 82 73 65 59 54 50 41
Q(m³/s)
Q(m3/hr)
141
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
3146 370 929 4 20/F 4.50 240/1/50 1195
Ps(Pa)
W(W)
RV/2-RVM3 58 93 89 83 72 68 61 59 53
Q(m³/s)
0 360 720 1080 1440 1800 2160 2520 2880 3240 3600
Q(m3/hr)
sez.
5
Box-D 9/9 A6M
230/1/50Hz
Nominal RPM - 950
Max Motor Input Power - 392 w
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
2509 245 392 6 20/F 2.60 240/1/50 908
Ps(Pa)
W(W)
RV/1-RVM2 51 86 81 75 67 61 54 52 44
Q(m³/s)
Q(m3/hr)
230/1/50Hz
Nominal RPM - 1315
Max Motor Input Power - 1243 w
Box-D 10/8 B4M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
3801 550 1243 4 20/F 6.10 240/1/50 1093
Ps(Pa)
W(W)
RV/2-RVM3 58 93 87 83 71 67 65 62 57
Q(m³/s)
Q(m3/hr)
142
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
230/1/50Hz
Nominal RPM - 920
Max Motor Input Power - 544 w
Box-D 10/8A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
2873 245 544 6 20/F 2.60 240/1/50 801
Ps(Pa)
W(W)
RV/1-RVM2 50 86 80 75 65 61 59 56 49
Q(m³/s)
Q(m3/hr) sez.
5
Box-D 10/10 B4M
230/1/50Hz
Nominal RPM - 1300
Max Motor Input Power - 1325 w
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
4327 550 1325 4 20/F 6.10 240/1/50 1036
Ps(Pa)
W(W)
RV/2-RVM3 58 91 88 84 72 67 65 63 58
Q(m³/s)
Q(m3/hr)
230/1/50Hz
Nominal RPM - 915
Max Motor Input Power -553 w Box-D 10/10 A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
3168 245 553 6 20/F 2.65 240/1/50 766
Ps(Pa)
W(W)
RV/1-RVM/2 51 86 81 76 65 60 59 58 49
Q(m³/s)
0 360 720 1080 1440 1800 2160 2520 2880 3240 3600
Q(m3/hr)
143
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
230/1/50Hz
Nominal RPM - 920
Max Motor Input Power -1369 w
Box-D 12/9 A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
5306 590 1369 6 20/F 6.80 240/1/50 771
Ps(Pa)
W(W)
RV/2-RVM3 58 89 89 81 71 69 68 64 57
Q(m³/s)
5
Q(m3/hr)
230/1/50Hz
Nominal RPM - 925
Max Motor Input Power - 1372
Box-D 12/12 A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
5731 590 1372 6 20/F 6.90 240/1/50 815
Ps(Pa)
W(W)
RV/1-RVM3 58 90 90 82 71 67 67 62 54
Q(m³/s)
Q(m3/hr)
144
Performance BOX-D
Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
6203 1100 1180 6 20/F 4.30 415/3/50 881
Ps(Pa)
W(W)
RVT/2 60 93 91 84 73 71 71 67 62
Q(m³/s)
0 720 1440 2160 2880 3600 4320 5040 5760 6480 7200
sez.
Q(m3/hr)
5
380/3/50Hz
Nominal RPM - 950
Max Motor Input Power -1487
Box-D 12/12 A6T
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
6519 1100 1487 6 20/F 4.70 415/3/50 895
Ps(Pa)
W(W)
RVT/2 61 92 93 84 75 70 70 65 59
Q(m³/s)
0 720 1440 2160 2880 3600 4320 5040 5760 6480 7200
Q(m3/hr)
145