Ambu BlueSensor NF
ECG Electrode - Single use

Key Benefits

• Skin-friendly solid gel


• Breathable soft cloth backing
• Unique offset connector
• High-quality Ag/AgCl sensor
• Available with various connectors and
colour coded lead wires

Ambu® BlueSensor NF
The very small Ambu BlueSensor NF has been specially Thanks to the cloth material, skin is able to breathe so the
developed for babies and smaller children. The electrode electrode remains comfortable to wear over long periods.
features a skin-friendly solid gel that ensures optimal The NF electrodes are available with a stud connector and
signal during long-term applications. colour-coded lead wires.

Solid gel Cloth backing


Specifications Connectors
Dimensions Environment
Electrode size* 44.3 x 22/ PVC-free electrode No
(max. L x W or diameter in mm) 30 x 22 Electrode not made with
Skin contact size natural rubber latex
(max. L x W or diameter in mm) 28 x 20 PVC-free lead wire No
Adhesive area (in mm2) 474 Wire not made with natural
Height excluding connector/wire (in mm) 1 rubber latex
Sensor PVC-free packaging Yes
S = Stud
Silver/silver X-ray & MRI
Sensor material Radiolucent No
chloride
Gel system Solid gel MR Conditional No
Sensor area* (in mm2) 33/54 Shelf life
Gel area/measuring area (in mm2) 474 In opened pouches 1 month
Electrical data (ANSI/AAMI) Unopened pouches** 24 months
AC impedance - typical 600 Ω
DC offset voltage - typical 0.2 mV *non-wire/wire **from date of production
Defibrillation overload recovery - typical 15 mV
F = 3 mm connector
Rate of change of polarization
0.5 mV/s
potential - typical
Combined offset instability and
<90 μV
internal noise
Bias current tolerance (over 8 hours) <30 mV

Material Pre wired connectors

Electrode Packaging
Bio-compatible Yes Pouches, inner layer Polyethylene (PE)
Silver/silver chloride Pouches, centre layer Aluminium (AI)
Sensor Pouches, outer layer Polyester (PET)
(Ag/AgCl)
Sponge - Boxes Cardboard
Outer carrier Non woven polyester Standard Packaging
Outer adhesive Solid gel Quantity/liner 3 A = 4 mm connector
Polyvinyl chloride/ Quantity/pouch 3, 12, 30
Upper part*
EVA-polyethylene Quantity/box 600/1200, 1200/2400
Fitting Polypropylene (PP) Minimum sales 1200
Connector (stud) Stainless steel
Eyelet Silver coated plastic Options
Lead wire core Copper Connectors S, F
Lead wire insulation Polyvinyl chloride Pre-wired Yes
Lead wire connector Brass/polypropylene Pre-wired connectors A, F, J, K
Liner Siliconized polyester film Precaution F = 3 mm connector
Single use only
*non-wire/wire

493 1001 01 - V07 - 2018/11 - Ambu A/S. Technical data may be modified without further notice. TCC 10606
Available configurations *
Quantity/pouch 3 12 30 Quantity/pouch 3 12 30
Quantity per inner/outer box Quantity per inner/outer box
NF-00-S 1200/2400 NF-50-J 600/1200
NF-00-F 600/1200 NF-50-K/EU** 600/1200 600/1200 J = 2 mm connector
NF-10-A, F 600/1200 NF-50-J/W** 600/1200
NF-50-A, F 600/1200 NF-50-K/W** 600/1200 600/1200
NF-50-K/US** 600/1200

*some configurations may not be available worldwide.


 Product ** EU = Coloured lead wire: red, yellow, black
NF-00-S  Wire length US = Coloured lead wire: green, black, white
 Connector W = Wound lead wire

K = 1.5 mm connector

Ambu A/S
Baltorpbakken 13
DK - 2750 Ballerup
Denmark
Tlf.: +45 7225 2000
www.ambu.com