0% found this document useful (0 votes)
62 views7 pages

Datasheet EE576

The document provides details about a compact probe for measuring very low air velocity. It operates using hot-film anemometry and is optimized for applications requiring accurate measurement of low velocities like laminar flow control or filter monitoring. Key features and specifications of the probe are described.

Uploaded by

1atera3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views7 pages

Datasheet EE576

The document provides details about a compact probe for measuring very low air velocity. It operates using hot-film anemometry and is optimized for applications requiring accurate measurement of low velocities like laminar flow control or filter monitoring. Key features and specifications of the probe are described.

Uploaded by

1atera3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Datasheet

EE576
Probe for Very Low Air Velocity
Datasheet EE576

EE576
Probe for Very Low Air Velocity
The compact EE576 probe is optimized for low air velocity measurement in applications like laminar flow control or filter
monitoring. It operates on the hot-film anemometer principle which stands for high accuracy and fast response time.

Reliability
The the flow sensing element manufactured in state-of-the-art E+E thin-film technology is highly insensitive to
contamination and offers excellent long-term stability.

Easy installation
The alignment strip on the probe facilitates the correct positioning in the air flow. The mounting flange within the scope of
supply enables accurate setting of the immersion depth.

Output
The measured data up to 1 m/s (200 ft/min) or 2 m/s (400 ft/min) is available on the 0 - 5 V or 0 - 10 V output.

EE576 air velocity probe with flange

v1.6 / Modification rights reserved | 2


Datasheet EE576

Features

Sensing head
▪ Protection rating IP20
▪ Polycarbonate (PC)
▪ Operates on the hot-film anemometer principle
▪ E+E thin-film technology
▪ Excellent long-term stability

Measurement performance
▪ High accuracy
▪ Measuring range:
Enclosure
▪ 0...1 m/s
▪ Protection rating IP40
▪ 0...2 m/s
▪ Polycarbonate (PC)
▪ Fast response time:
▪ 4 s @ 1 m/s

Mounting flange
▪ Easy and quick mounting
▪ Accurate setting of the immersion depth

v1.6 / Modification rights reserved | 3


Datasheet EE576

Dimensions
Values in mm (inch)

Probe
Polycarbonate (PC)

150 (6)

120 (4.7)
(0.5)
Ø12

Alignment strip Cable length:


0.5 m (19.7)

Front sensing head

13.4 (0.5)
1.5 (0.1)

The arrow indicates the air flow Alignment strip


direction during factory adjustment

Mounting flange Mounting flange


Included in the scope of supply Side view

80 (3.1)
2.5
60 (2.4) (0.1)
(0.2)
44 (1.7)

Bore diameter
6

≥ 16 (0.6)

24.5 (0.9)

v1.6 / Modification rights reserved | 4


Datasheet EE576

Technical Data
Measurands

Air Velocity (v)


Measuring range 0...1 m/s (0...200 ft/min)
0...2 m/s (0...400 ft/min)

Accuracy1)
@ 20 °C (68 °F), 45 %rF und 1 013 hPa (14.7 psi)
0.2...1 m/s (40...200 ft/min) ±(0.05 m/s +2 % of mv)  mv = measured value
0.2...2 m/s (40...400 ft/min) ±(0.08 m/s +4 % of mv)

Response time t90, typ. 4 s bei 1 m/s (200 ft/min)

1) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation).
The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).

Output

Analogue
Air velocity (v) 0-5V
0 < IL < 1 mA  IL = load current
0 - 10 V

General

Power supply class III 10 - 19 V DC or 19 - 29 V DC


USA & Canada: Class 2 supply necessary

Current consumption, max. 70 mA


@ 2 m/s (400 ft/min)

Humidity range
Operation and Storage 10…95 %RH, non-condensing

Temperature range
Operation -20...+60 °C (-4...+140 °F)
Storage -30...+60 °C (-22...+140 °F)

Probe cable Polyvinylchloride (PVC), 3 x 0.25 mm2 with wire ferrules

Probe material Polycarbonate (PC)

Protection rating
Probe head IP20
Probe IP40

Electromagnetic compatibility EN 61326-1 EN 61326-2-3 Industrial environment


FCC Part15 Class B ICES-003 Class B

Conformity

v1.6 / Modification rights reserved | 5


Datasheet EE576

Ordering Guide
Feature Description Code
EE576-
Hardware Configuration

Output 0-5V A2
0 - 10 V (with 19 - 29 V DC supply only) A3
Measuring range 0...1 m/s (0...200 ft/min) HV21
0...2 m/s (0...400 ft/min) HV23
Power supply 10 - 19 V DC V5
19 - 29 V DC V6
Connection cable length 0.5 m (1.64 ft) KL50
2 m (6.56 ft) KL200

Order Example
EE576-A2HV23V5KL200

Feature Code Description


Output A2 0-5V

Measuring range HV23 0...2 m/s (0...400 ft/min)

Power supply V5 10 - 19 V DC

Connection cable length KL200 2 m (6.56 ft)

v1.6 / Modification rights reserved | 6


Company Headquarters &
Production Site

E+E Elektronik Ges.m.b.H.


Langwiesen 7
4209 Engerwitzdorf | Austria
T +43 7235 605-0
F +43 7235 605-8
info@epluse.com
www.epluse.com

Subsidiaries

E+E Sensor Technology (Shanghai) Co., Ltd.


T +86 21 6117 6129
info@epluse.cn

E+E Elektronik France SARL


T +33 4 74 72 35 82
info.fr@epluse.com

E+E Elektronik Deutschland GmbH


T +49 6171 69411-0
info.de@epluse.com

E+E Elektronik India Private Limited


T +91 990 440 5400
info.in@epluse.com

E+E Elektronik Italia S.R.L.


T +39 02 2707 86 36
info.it@epluse.com

E+E Korea Co., Ltd.


T +82 31 732 6050
info.kr@epluse.com

E+E Elektronik Corporation


T +1 847 490 0520
info.us@epluse.com

Version v1.6 | 01-2023


Modification rights reserved

You might also like