0% found this document useful (0 votes)
38 views5 pages

Building Permit Scrutiny Report

The document provides details of a building permit application for a residential construction project. It includes details of the plot, building plans, and scrutiny of the plans against building regulations. Upon scrutiny, the plans were found to not satisfy regulations regarding maximum floor space index allowed for the plot.

Uploaded by

muthukumar007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views5 pages

Building Permit Scrutiny Report

The document provides details of a building permit application for a residential construction project. It includes details of the plot, building plans, and scrutiny of the plans against building regulations. Upon scrutiny, the plans were found to not satisfy regulations regarding maximum floor space index allowed for the plot.

Uploaded by

muthukumar007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Tamilnadu State Wide Single Window Portal

AUTOMATED BUILDING PERMIT APPROVAL SYSTEM


PLAN DOCUMENT SCRUTINY REPORT

STATUS : Not Satisfied


APPLICATION DETAILS

1 APPLICANT NAME Janyamkondam 2 APPLICATION DATE 22/05/2024

3 APPLICATION NUMBER 494310-2024-FR 4 APPLICATION TYPE Permit

5 OCCUPANCY TYPE Residential 6 DCR NUMBER NA


REGISTERED
7 ARCHITECT/ENGINEER - 8 DEVELOPMENT TYPE New Construction

PLOT DETAILS

1 SURVEY NO 123

2 PLOT NO 171 3 PATTA NO 321

4 TALUK Udayarpalayam 5 DISTRICT Ariyalur


PLOT AREA (As per PLOT AREA (As per
6 declaration) in m² 229.0 7 measurement) in m² 229.00
AVERAGE WIDTH OF PLOT AVERAGE DEPTH OF PLOT
8 in m 13.0 9 in m 17.5
SURRENDER ROAD WIDTH
10 ROAD WIDTH in m 8.17 11 AREA in m² 0.00

AREA TYPE
(Continuous/Economically
12 Weaker Section/Others) CBA 13 DEMOLITION AREA in m² 0

OSR SURRENDER/
14 OSR APPLICABLE NO 15 BUYBACK/ RETAIN

Queries
1. General stair flight is not defined in block 1 floor 1
2. General Stair landing not defined in block 1 floor 1 stair 1
3. General stair not defined in Block 1 floor 2
4. Kitchen room not defined in the plan.
5. Block 1 Portico 1 Portico distance to exteriorwall not defined in the plan.

Overall Summary

Total Area
Built Up Area in m² Carpet Area in m² Covered Area in m² FSI Area in m² Non FSI Area in m²
744.51 0.00 187.36 744.51 0.00

Plot Area Details


Description Area in m²
As At Site 229.00
FMB or PLR 229.00

Application No:494310-2024-FR, Scrutiny Date:22/05/2024 04:59 PM


1 of 5
Description Area in m²
As Per Document 229.00

Block Wise Summary

Block No 1 - Proposed Details


Deduction Area in Non FSI Area in
Floor Occupancy/Sub Occupancy Floor Area in m²

FSI Area in m²

Carpet Area in m²

0 Individual residence 187.35 0 187.35 0 0


1 Individual residence 185.72 0 185.72 0 0
2 Individual residence 185.72 0 185.72 0 0
3 Individual residence 185.72 0 185.72 0 0
Total 744.51 0.00 744.51 0.00 0.00

1. Covered Area is 187.36 m²


2. Height of building is 11.62 m
3. Head Room Area (Non FSI Area) is 0 m²
4. Total Non FSI Area is 0.00 m²

Common - Scrutiny Details

1.No. of Blocks
Description Provided Status
Total Number Of Blocks 1 Verified

2.FSI
As per TNCDBR Occupancy Area Type Road Width Required Provided Status
Part VI Pt.35 / pt.36/ Residential CBA 8.17 <= 2 3.251 Not Satisfied
pt.37/ pt.38/ pt.39

3.Floor Units
Block Floor Unit Number Unit Area
Block 1 Floor 0 1 187.35 Sq.m
Block 1 Floor 1 1 185.72 Sq.m
Block 1 Floor 2 1 185.72 Sq.m
Block 1 Floor 3 1 185.72 Sq.m

4.Parking
As per TNCDBR Description Required Provided Status
Annexure iv - part I-13,17,b,part Parking Slots Area 5 M x 2.5 M Minimum Area of No violation of area in 4 parking Verified
II-A,C Each parking
Annexure iv - part I-13,17,b,part Two wheeler parking dimension 1 M x 1.8 M Out of 9 parking 0 parking Verified
II-A,C violated dimension.
Annexure iv - part I-13,17,b,part Car Parking 4 4 Verified
II-A,C
Annexure iv - part I-13,17,b,part Two Wheeler Parking 0 9 Verified
II-A,C

5.Drive Way
As per TNCDBR Description Required Provided Status

Application No:494310-2024-FR, Scrutiny Date:22/05/2024 04:59 PM


2 of 5
As per TNCDBR Description Required Provided Status
Annexure-IV,Part-I(1),Part- Width of driveway(Four Wheeler) 6 m 7.20 m Verified
II(A)(B)(C)
Annexure-IV,Part-I(1),Part- Width of driveway(Two Wheeler) 1.5 m 1.5 m Verified
II(A)(B)(C)

6.Bathroom Water Closets


As per TNCDBR Description Required Provided Status
Part vii-pt52-7 Bathroom Water Closets Height >= 2.1, Area >= 2.4, Width Height >= 3.04, Area >= 3.63, Verified
>= 1.2 Width >= 1.22
Part vii-pt52-7 Bathroom Water Closets Height >= 2.1, Area >= 2.4, Width Height >= 3.04, Area >= 3.63, Verified
>= 1.2 Width >= 1.22

7.Solar
As per TNCDBR Description Required Provided Status
Part VI 44(2) Solar Assisted Water Heating / Defined in the plan. Verified
Lighting system

8.Height of Building
As per TNCDBR Description Required Provided Status
Part VI Pt.35 / pt.36/ pt.37/ pt.38/ Height of Building for Block 1 14m / G+2 or Stilt +3 / up to 16 11.62m / 4 Floors / 0 Dwelling Verified
pt.39 Dwelling Units units

9.Collection and disposal of Solid and Liquid Waste


As per TNCDBR Description Field Verified Status
part vi-pt 35-17 Collection and disposal of solid and liquid Defined in the Plan. Verified
Waste

10.Rain Water Harvesting


As per TNCDBR Description Provided Status
Annexure XXII-A Rain Water Harvesting Defined in the plan Verified

11.Travel Distance To Emergency Exits


Maximum travel distance to emergency exit
As per TNCDBR Required Provided Status
42-2 22.5m 7.80m Verified

12.North Direction
As per TNCDBR Description Provided Status
part ii - 8 -iii-(l) North Direction North directions provided Verified

13.Location Plan
As per TNCDBR Description Provided Status
part ii - 8 -i Location Plan Location plans provided Verified

14.Toilet Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Toilet Ventilation Min 0.5 Sq.m 0.80 Sq.m Verified

15.Road Width
As per TNCDBR Description Occupancy Required Provided Status
Part VI Road Width Individual residence >=1.5m 8.17m Verified

Block 1 - Scrutiny Details

Application No:494310-2024-FR, Scrutiny Date:22/05/2024 04:59 PM


3 of 5
1.Setback
As per TNCDBR Setback Occupancy Level Field Verified Required Provided Status
Part VI, Pt.35 / Front Individual 0 Minimum distance 1.5 1.60 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39

Part VI, Pt.35 / Rear Individual 0 Minimum distance 0 0.12 Verified


pt.36/ pt.37/ pt.38/ residence
pt.39

Part VI, Pt.35 / Side Setback 1 Individual 0 Minimum distance 0 0.09 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39

Part VI, Pt.35 / Side Setback 2 Individual 0 Minimum distance 0 0.11 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39

2.General Stair - Mid landing


As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum width for general 0.75 1.52 Verified
stair 1 mid landing

Part VII , 52(17) floor 0 Minimum width for general 0.75 1.52 Verified
stair 1 mid landing

3.General Stair - Number of risers


As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Maximum no of risers 15 3 Verified
required per flight for
general stair 1 flight 1

Part VII , 52(17) floor 0 Maximum no of risers 15 8 Verified


required per flight for
general stair 1 flight 2

Part VII , 52(17) floor 0 Maximum no of risers 15 6 Verified


required per flight for
general stair 1 flight 3

4.General Stair - Tread width


As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.46 Verified
stair 1 flight 1

Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.30 Verified
stair 1 flight 2

Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.43 Verified
stair 1 flight 3

5.General Stair - Width


As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum width for general 0.75 1.52 Verified
stair 1 flight 1

Part VII , 52(17) floor 0 Minimum width for general 0.75 1.52 Verified
stair 1 flight 2

Application No:494310-2024-FR, Scrutiny Date:22/05/2024 04:59 PM


4 of 5
As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum width for general 0.75 1.52 Verified
stair 1 flight 3

6.Plinth
As per TNCDBR Description Required Provided Status
part vii-pt52-1 Minimum plinth height >= 0.45m 0.45m Verified

7.Portico
As per TNCDBR Description Required Provided Status
PORTICO DEDUCTION AREA Portico 1 deduction area - 0 Sq.Mtr. Verified

8.Room
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-5,6,9,10 Minimum height of room floor 1 2.75m 3.35m Verified

part vii-pt52-5,6,9,10 Minimum height of room floor 2 2.75m 3.04m Verified

part vii-pt52-5,6,9,10 Minimum height of room floor 3 2.75m 3.04m Verified

10.Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 30.56 of Room Verified
Area 0.00 at floor 1

part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 24.04 of Room Verified
Area 0.00 at floor 2

part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 24.04 of Room Verified
Area 0.00 at floor 3

This report is generated based on the Applicant Declaration and a provided drawing. The drawing has been verified with TNCDBR
rules and final decision on approval will be taken by Department officials. Completion Certificate will not be issued if any deviation
from the submitted drawing more than tolerance Limits.

Application No:494310-2024-FR, Scrutiny Date:22/05/2024 04:59 PM


5 of 5

You might also like