Tamilnadu State Wide Single Window Portal
AUTOMATED BUILDING PERMIT APPROVAL SYSTEM
PLAN DOCUMENT SCRUTINY REPORT
STATUS : Verified
APPLICATION DETAILS
1 APPLICANT NAME MURUGAN PERUMAL 2 APPLICATION DATE 15/05/2024
3 APPLICATION NUMBER 471132-2024-LI 4 APPLICATION TYPE Permit
5 OCCUPANCY TYPE Residential 6 DCR NUMBER DCR52024CK8CD
REGISTERED
7 ARCHITECT/ENGINEER - 8 DEVELOPMENT TYPE
PLOT DETAILS
1 SURVEY NO 86/9A
2 PLOT NO 3 PATTA NO 2020
4 TALUK Dindigul East 5 DISTRICT Dindigul
PLOT AREA (As per PLOT AREA (As per
6 declaration) in m² 192.2 7 measurement) in m² 192.20
AVERAGE WIDTH OF PLOT AVERAGE DEPTH OF PLOT
8 in m 12.2 9 in m 9.06
SURRENDER ROAD WIDTH
10 ROAD WIDTH in m 6.10 11 AREA in m² 0.00
AREA TYPE
(Continuous/Economically
12 Weaker Section/Others) OTHERS 13 DEMOLITION AREA in m² 0
OSR SURRENDER/
14 OSR APPLICABLE NO 15 BUYBACK/ RETAIN
Overall Summary
Total Area
Built Up Area in m² Carpet Area in m² Covered Area in m² FSI Area in m² Non FSI Area in m²
156.88 0.00 73.38 156.88 0.00
Plot Area Details
Description Area in m²
As At Site 192.20
FMB or PLR 192.20
As Per Document 192.20
Block Wise Summary
Application No:471132-2024-LI, Scrutiny Date:15/05/2024 07:57 PM
1 of 5
Block No 1 - Existing Details
Deduction Area in Non FSI Area in
Floor Occupancy/Sub Occupancy Floor Area in m²
m²
FSI Area in m²
m²
Carpet Area in m²
0 Individual residence 78.44 0 78.44 0 0
Total 78.44 0.00 78.44 0.00 0.00
Total Existing Areas
Floor Area in m² FSI Area in m² Carpet Area in m²
78.44 78.44 0.00
Block No 1 - Proposed Details
Deduction Area in Non FSI Area in
Floor Occupancy/Sub Occupancy Floor Area in m²
m²
FSI Area in m²
m²
Carpet Area in m²
Proposed Individual residence
First Floor 78.44 0 78.44 0 0
Total 78.44 0.00 78.44 0.00 0.00
1. Covered Area is 73.38 m²
2. Height of building is 6.79 m
3. Head Room Area (Non FSI Area) is 0 m²
4. Total Non FSI Area is 0.00 m²
Total Proposed Areas
Floor Area in m² FSI Area in m² Carpet Area in m²
78.44 78.44 0.00
Common - Scrutiny Details
1.No. of Blocks
Description Provided Status
Total Number Of Blocks 1 Verified
2.FSI
As per TNCDBR Occupancy Area Type Road Width Required Provided Status
Part VI Pt.35 / pt.36/ Residential OTHERS 6.10 <= 2 0.816 Verified
pt.37/ pt.38/ pt.39
3.Floor Units
Block Floor Unit Number Unit Area
Block 1 Floor 1 1 73.38 Sq.m
4.Parking
As per TNCDBR Description Required Provided Status
Annexure iv - part I-13,17,b,part Parking Slots Area 5 M x 2.5 M Minimum Area of No violation of area in 1 parking Verified
II-A,C Each parking
Annexure iv - part I-13,17,b,part Two wheeler parking dimension 1 M x 1.8 M Out of 1 parking 0 parking Verified
II-A,C violated dimension.
Application No:471132-2024-LI, Scrutiny Date:15/05/2024 07:57 PM
2 of 5
As per TNCDBR Description Required Provided Status
Annexure iv - part I-13,17,b,part Car Parking 0 1 Verified
II-A,C
Annexure iv - part I-13,17,b,part Two Wheeler Parking 1 1 Verified
II-A,C
5.Septic Tank/drainage
As per TNCDBR Description Status
Part VII , 54-3(b) Septic Tank/drainage Provided Verified
6.Parapet
As per TNCDBR Description Required Provided Status
Part VII , 52(13) Parapet Height >= 1.2 and height <= 1.5 Height >= 1.21 and height <= Verified
1.21
7.Solar
As per TNCDBR Description Required Provided Status
Part VI 44(2) Solar Assisted Water Heating / Defined in the plan. Verified
Lighting system
8.No. of Dwelling units
Description Provided Status
Total Dwelling units 2 Verified
9.Height of Building
As per TNCDBR Description Required Provided Status
Part VI Pt.35 / pt.36/ pt.37/ pt.38/ Height of Building for Block 1 14m / G+2 or Stilt +3 / up to 16 6.79m / 2 Floors / 2 Dwelling Verified
pt.39 Dwelling Units units
10.Collection and disposal of Solid and Liquid Waste
As per TNCDBR Description Field Verified Status
part vi-pt 35-17 Collection and disposal of solid and liquid Defined in the Plan. Verified
Waste
11.Rain Water Harvesting
As per TNCDBR Description Provided Status
Annexure XXII-A Rain Water Harvesting Defined in the plan Verified
12.North Direction
As per TNCDBR Description Provided Status
part ii - 8 -iii-(l) North Direction North directions provided Verified
13.Location Plan
As per TNCDBR Description Provided Status
part ii - 8 -i Location Plan Location plans provided Verified
14.Toilet Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Toilet Ventilation Min 0.5 Sq.m 0.71 Sq.m Verified
15.Road Width
As per TNCDBR Description Occupancy Required Provided Status
Part VI Road Width Individual residence >=3m 6.10m Verified
Application No:471132-2024-LI, Scrutiny Date:15/05/2024 07:57 PM
3 of 5
Block 1 - Scrutiny Details
1.Setback
As per TNCDBR Setback Occupancy Level Field Verified Required Provided Status
Part VI, Pt.35 / Front Individual 0 Minimum distance 1.5 5.00 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VI, Pt.35 / Rear Individual 0 Minimum distance 0 1.00 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VI, Pt.35 / Side Setback 1 Individual 0 Minimum distance 1 1.0 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VI, Pt.35 / Side Setback 2 Individual 0 Minimum distance 1 1.0 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
2.General Stair - Mid landing
As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum width for general 0.75 0.90 Verified
stair 1 mid landing
3.General Stair - Number of risers
As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Maximum no of risers 15 10 Verified
required per flight for
general stair 1 flight 1
Part VII , 52(17) floor 0 Maximum no of risers 15 2 Verified
required per flight for
general stair 1 flight 2
4.General Stair - Tread width
As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.31 Verified
stair 1 flight 1
Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.75 Verified
stair 1 flight 2
5.General Stair - Width
As per TNCDBR Floor Description Required Provided Status
Part VII , 52(17) floor 0 Minimum width for general 0.75 0.90 Verified
stair 1 flight 1
Part VII , 52(17) floor 0 Minimum width for general 0.75 0.90 Verified
stair 1 flight 2
6.Kitchen
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-6 Minimum height of kitchen floor 0 2.75m 3.00m Verified
part vii-pt52-6 Total area of kitchen floor 0 5.00Sq.m 8.33Sq.m Verified
Application No:471132-2024-LI, Scrutiny Date:15/05/2024 07:57 PM
4 of 5
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-6 Minimum Width of kitchen floor 0 1.80m 2.73m Verified
part vii-pt52-6 Minimum height of kitchen floor 1 2.75m 3.00m Verified
part vii-pt52-6 Total area of kitchen floor 1 5.00Sq.m 12.02Sq.m Verified
part vii-pt52-6 Minimum Width of kitchen floor 1 1.80m 3.05m Verified
7.Kitchen Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 2.46 of Kitchen Verified
Area 8.33 at floor 0
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 1.84 of Kitchen Verified
Area 12.02 at floor 1
8.Plinth
As per TNCDBR Description Required Provided Status
part vii-pt52-1 Minimum plinth height >= 0.45m 0.6m Verified
9.Room
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-5,6,9,10 Minimum height of room floor 0 2.75m 3.0m Verified
Minimum Width of room floor 0 2.4m 2.60m Verified
part vii-pt52-5,6,9,10 Minimum height of room floor 1 2.75m 3.0m Verified
11.Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 8.91 of Room Verified
Area 7.93 at floor 0
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 8.22 of Room Verified
Area 41.21 at floor 1
This report is generated based on the Applicant Declaration and a provided drawing. The drawing has been verified with TNCDBR
rules and final decision on approval will be taken by Department officials. Completion Certificate will not be issued if any deviation
from the submitted drawing more than tolerance Limits.
Application No:471132-2024-LI, Scrutiny Date:15/05/2024 07:57 PM
5 of 5