0% found this document useful (0 votes)
14 views62 pages

The Ventilation of Buildings and Other Mitigating Measures For COVID-19: A Focus On Winter 2020

The document discusses mitigating measures for COVID-19 transmission in buildings during winter 2020, focusing on ventilation and aerosol transmission. It reviews knowledge on indoor spread of COVID-19 and presents new results to inform UK guidance. Key findings are that adequate outdoor air ventilation based on existing design guidance can help reduce airborne transmission risk, and social distancing, face coverings, hand hygiene and surface cleaning can help reduce droplet and contact transmission risks.

Uploaded by

SemaccaLH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views62 pages

The Ventilation of Buildings and Other Mitigating Measures For COVID-19: A Focus On Winter 2020

The document discusses mitigating measures for COVID-19 transmission in buildings during winter 2020, focusing on ventilation and aerosol transmission. It reviews knowledge on indoor spread of COVID-19 and presents new results to inform UK guidance. Key findings are that adequate outdoor air ventilation based on existing design guidance can help reduce airborne transmission risk, and social distancing, face coverings, hand hygiene and surface cleaning can help reduce droplet and contact transmission risks.

Uploaded by

SemaccaLH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 62

The ventilation of buildings and other mitigating measures for

COVID-19: a focus on winter 2020

The Royal Society ‘Rapid Assistance for Modelling the Pandemic (RAMP)’ project
Task 7: Environmental and aerosol transmission

September 30, 2020


arXiv:2009.12781v2 [physics.soc-ph] 29 Sep 2020

This document constitutes draft guidance which has been published for consultation pur-
poses only.
The intended audience include: advisors to UK Government (e.g. SAGE), Public Health
England, relevant government departments (e.g. the Department for Education), ventila-
tion practitioners (e.g. manufacturers and designers), skilled building service managers,
and interested scientists.

1 Executive summary
Winter 2020 presents significant risks in managing the ventilation of buildings and maintaining a healthy
indoor environment. The extent of the COVID-19 pandemic, both in terms of its stage of development
and the controlling measures in-place, varies widely across the globe both inter- and intra-country. Within
the United Kingdom of Great Britain and Northern Ireland (UK) the disease seems to be at a dangerous
juncture with the reproductive number (i.e. the average number of infections arising from a single
infectious case) currently above one for COVID-19 (e.g. the R-number is being reported, as of September
18, as 1.1–1.4, UK Government, 2020). This is at a time when cooler weather is approaching where
people typically spend longer indoors in the company of others and the supply of outdoor ventilation
air is reduced. Simultaneously, the UK and other governments are trying to re-open their economies,
which is accompanied by increased social interactions (e.g. schools reopened in August and September
2020 throughout the UK, with universities soon to follow). This report is intended to review much of
the knowledge surrounding the indoor spread of COVID-19, and present new results which can inform
guidance for mitigating the impact of the disease — our focus has been the UK but our findings will be
more widely useful.
It is the premise of this report that COVID-19 may be spread via three main routes (droplet, contact and
airborne) all of which we assume to be potentially significant. By consideration of the indoor environment
and our behaviour within it, we discuss potential mitigating strategies for all three routes. However,
our primary focus is the airborne/aerosol route, since mitigating the spread via this route is the most
challenging. The evidence suggests that adequate supply of outside (or at least uncontaminated) air is
crucial in helping ensure the reproductive number of a particular indoor space is minimised and ideally
remains below one. Findings suggest that for many indoor spaces which are regularly attended by the
same/similar group of people (e.g. an open plan office or school classroom) adhering to existing design
guidance for adequate ventilation (e.g. 10 litres per second per person, or 10 l/s/p, for offices (CIBSE,
2015) and 5–10 l/s/p for school classrooms (see DepartmentforEducation, 2018a)) and occupancy densi-
ties, results in airborne infection risk that remains relatively low for most reasonable scenarios. Modelling
estimates suggest that in these cases the reproductive number is less than one suggesting each infection
is expected to give rise to less than one new infection. However, for any indoor space where respiratory
activity levels of a potential infector are expected to increase to anything above those corresponding to
sedentary talking, increased caution is required.
Appropriate social distancing (§2.2) and/or the wearing of face coverings appear to be effective measures
to help mitigate the risk of transmission via the droplet route. Increased hand hygiene and the cleaning
of surfaces, particularly high-touch public surfaces (i.e., those frequently touched by more than one

1
individual), will reduce transmission via the contact route. Cleaning of surfaces using disinfectants
based on alcohols and reduced contact with these surfaces appear to be effective measures to reduce
transmission (§2.1.2). Indoor spaces that bring individuals together over long periods, e.g. open-plan
offices, school classrooms and the like, or those that lead to increased respiratory activity, e.g. gyms,
choral halls, etc..., are expected to make the airborne spread of the virus an important consideration.
Assessment of the ventilation provision, or where practical the monitoring of CO2 levels to indicate
ventilation provision (§3), can help manage the risk of COVID-19 transmission via the airborne route in
winter 2020. Most documented cases of transmission which are believed to have arisen from the airborne
route have been in environments where the outdoor air supply would not have complied with current
UK design guidance. It is inferred from this, and the documented modelling, that provision of outdoor
air in-line with existing design guidance will help reduce the risk of transmission by the airborne route.
The rate of provision of outdoor air can be inferred by monitoring CO2 levels, maintaining these below
about 1 000 ppm being indicative of adequate ventilation in many indoor spaces, including offices (with
design guidance for some indoor spaces permitting 1 500 ppm see DepartmentforEducation, 2018a, and
§3.2 for a fuller discussion). However, higher ventilation rates may be needed wherever activity levels
increase beyond desk-based work. Risks cans also be reduced by reducing occupancy (whilst ensuring
full outdoor air supply rates are maintained), staggering occupancy (via appropriate timetabling) and
by the purging of indoor spaces between events (§2.4). Numerous additional engineering strategies are
available to help further reduce the risk of transmission and we review these in detail (see §4).
The review of current knowledge has identified the following key research questions.
• What are the SARS-COV-2 viral load distributions and respiratory droplet size distributions emit-
ted by an individual carrying out activities such as sitting, walking, talking, singing, sneezing,
coughing? How might these vary with an individual’s size, age, etc...?
• What is the trajectory of droplets and aerosols containing viral particles from exhalation to re-
moval under different ventilation modes, occupancy levels, occupant behaviour/movement, and
environmental conditions (e.g. temperature, humidity, etc...)?
• How can risk and severity of infection of an individual be determined from the nature of viral
exposure (i.e. how and where droplets or viral particles are deposited in the respiratory system of
an individual, their frequency, the peak/cumulative dose, etc...)?
• What processes determine the timescales for purging a space or determining the frequency of
cleaning and which environmental condition affect these?
• What are the quantitative impacts of wearing face coverings?
• How effective are localised outdoor air supplies and/or purification methods, and what factors
affect their results?
• How can existing knowledge, and perhaps answers to the above questions, be deployed to better
understand and predict the spread of COVID-19, for which high-spreading statistical outlier events
(so called ‘superspreaders’) appear to be significant?

2
Contents
1 Executive summary 1

2 The indoor spread of COVID-19 and winter 2020 5


2.1 COVID-19 transmission indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1.1 Transmission via droplets and aerosols . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1.2 Transmission via surface contacts and fomites . . . . . . . . . . . . . . . . . . . . . 7
2.2 Social distancing indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Guidance on face masks and coverings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3.1 A summary of the evidence base for the use of face masks and coverings . . . . . . 10
2.4 Source reduction through timetabling and purging between events . . . . . . . . . . . . . 11
2.5 The influence of occupancy behaviour on indoor air movement: implications for the spread
of COVID-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3 Ventilation and the airborne transmission route 14


3.1 Towards an understanding of ventilation and COVID-19 . . . . . . . . . . . . . . . . . . . 14
3.2 Ventilation guidance for winter 2020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4 Other mitigating measures 18


4.1 Air filters or cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2 Personalised ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.3 Desk and ceiling fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.4 Air ionisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.5 The use of screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.6 Upper room Ultra-Violet Germicidal Irradiation . . . . . . . . . . . . . . . . . . . . . . . . 21
4.7 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

5 Author contributions 22

A Natural inputs to ventilation provision 23


A.1 Natural Ventilation in winter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
A.1.1 Adjusting airflow through natural ventilation openings . . . . . . . . . . . . . . . . 24
A.1.2 Occupant Comfort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
A.2 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

B SARS-CoV-2 on hard surfaces 26


B.1 Surface deposition and contact frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
B.2 Factors affecting survival of virus on surfaces . . . . . . . . . . . . . . . . . . . . . . . . . 27
B.2.1 Surface material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
B.2.2 Effects of temperature and humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 29
B.2.3 Effects of surface finish, texture or roughness . . . . . . . . . . . . . . . . . . . . . 29
B.3 Modeling approaches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
B.3.1 A model to predict viral transfer from surfaces . . . . . . . . . . . . . . . . . . . . 30
B.3.2 A model to predict viral decay rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
B.3.3 Droplet evaporation from a surface . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
B.3.4 Modelling of droplet residue and how its mechanical performance and attachment
to surfaces could influence its survival . . . . . . . . . . . . . . . . . . . . . . . . . 31
B.4 Self-inoculation via hand-to-face contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
B.5 Cleaning and disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
B.5.1 What is an effective detergent? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
B.5.2 What is an effective disinfectant? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
B.5.3 Light deactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
B.6 Science behind current UK government advice . . . . . . . . . . . . . . . . . . . . . . . . . 34
B.7 Conclusions and key questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

C UVGI and COVID-19 34


C.0.1 UVGI inactivation Kinetics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
C.0.2 Susceptibility of SARS-CoV-2 to UVGI . . . . . . . . . . . . . . . . . . . . . . . . 36

3
C.1 UVGI air disinfection applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
C.1.1 Target microbes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
C.1.2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C.1.3 What UVGI can and cannot do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C.2 Upper-room UVGI air disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C.2.1 Calculating the required UV flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C.2.2 Upper-room UVGI feasibility study . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
C.2.3 Room air movement and particle decoupling . . . . . . . . . . . . . . . . . . . . . . 43
C.3 In-duct UVGI air disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
C.3.1 Where should in-duct UVGI lamps be placed? . . . . . . . . . . . . . . . . . . . . 45
C.3.2 Failing safe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
C.3.3 Computation of the UV flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
C.4 UVGI room air cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
C.5 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
C.6 Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

D Summary of current recommendations for the use of face masks or coverings (August
2020) 48

E Aerosols in the context of singing, and woodwind & brass musical instruments 49

4
2 The indoor spread of COVID-19 and winter 2020
Florence Nightingale is credited with having promoted the idea that the indoor environment plays a
critical role in determining health outcomes. Her pioneering work on hospital ward design is still highly
relevant with the guiding principles of high ceilings, adequate natural lighting, and sufficient ventilation
proving sound design for any indoor environment. However, modern architectural approaches, which
often rely on mechanical means to condition the environment, may not follow these principles. In this
document we focus on two indoor spaces, namely, open-plan offices and school classrooms, because these
constitute spaces which are recurrently attended by the same group of people, are occupied for significant
portions of each weekday, are frequently populated at moderate to high occupancy density and do not
often adhere to Nightingale’s design principles. In short, these settings contain very common spaces in
which a significant proportion of the population may potentially be at moderate to high risk of exposure
to the COVID-19 corona virus. However, the findings and guidance reported within this document apply
generically to almost all indoor spaces and we urge that the guiding principles be widely applied.

2.1 COVID-19 transmission indoors

The novel coronavirus disease (COVID-19), which causes respiratory and other symptoms, was declared
a pandemic by the World Health Organization (WHO) in March 2020. Transmission of such respiratory
infections occurs via virions encapsulated in particles of respiratory secretions (in this case the virus
SARS-CoV-2) formed in the respiratory tract of an infected person and spread to other humans via
three routes: the droplet route, the contact route and the airborne route (Mittal et al., 2020).
The droplet route involves the transfer of respiratory droplets from an infected person to the mucous
membranes of a subject, i.e. respiratory droplets land in the mouth, nose or eyes of others. The contact
route takes place when respiratory droplets are deposited onto surfaces that are then touched by other
people who go on to touch their mouth, nose or eyes before washing their hands. The airborne route
(also called aerosol transmission) occurs when exhaled respiratory droplets are small enough to remain
suspended in air such that they can be inhaled into the respiratory system of other people.
At the beginning of the COVID-19 pandemic, a lack of direct empirical evidence on airborne trans-
mission of SARS-CoV-2 highly influenced health policy decisions which were intended to control the
pandemic and the public response to it. However, an increasing body of evidence (particularly in poorly
ventilated indoor environments), a better understanding of the disease progression, and information on
the asymptomatic and pre-symptomatic transmission of the virus strongly support the case for airborne
transmission of SARS-CoV-2 virus (see Morawska et al., 2020; Morawska & Milton, 2020, for discussion
and the references therein).
In an indoor environment the ventilating flow modulates the transport and advection of any aerosols (in-
cluding bio-aerosols), pollutants, and CO2 produced by indoor-sources/occupants and further determines
their subsequent removal from within the indoor environment. Traditionally, building ventilation has
been studied in the context of thermal comfort and in the last few decades energy efficiency. However,
there has been a timely shift of focus and, in addition to energy efficiency and thermal comfort, indoor
air quality (and implicitly the removal of any indoor airborne pollutants produced by the occupants)
has become a core focus (Sloan Brittain et al., 2020). Within our guidance we exploit this cutting-edge
knowledge to offer advice to mitigate COVID-19 spread via the airborne route. However, it is essential
not to do so at the expense of considering droplet transmission and contact transmission, and measures
to minimise the risk of transmission via these routes must be given as much priority as consideration of
the airborne route. As such, within this section we review transmission via the droplet and aerosols route
(§2.1.1) and contact routes (§2.1.2), we then consider the role that social distancing (§2.2), face coverings
(§2.3), and occupancy behaviour (§2.5) can play in affecting the various modes of transmission. In §3
we address the role of ventilation in influencing the airborne transmission route. We go on to discuss
the suitability of other measures in mitigating the spread (§4) and we present three appendices covering:
factors affecting, and modelling considerations for, surface transmission (appendix B), details of the po-
tential for ultraviolet germicidal irradiation (UVGI) air disinfection to mitigate COVID-19 transmission
(appendix C), and details of current governmental guidance for face coverings (appendix D).

5
2.1.1 Transmission via droplets and aerosols

Respiratory diseases are transmitted by exposure to pathogen-laden droplets produced by expiratory


events such as breathing, coughing, sneezing, speaking, singing and laughing (Stelzer-Braid et al., 2009;
Yan et al., 2018). The expiratory droplets range between 0.01−1000 µm (Bake et al., 2019), and con-
ventionally they are classified in two categories; droplets smaller than 5 µm are referred to as droplet
nuclei or aerosols, whereas droplets larger than 5−10 µm in diameter are classified as respiratory droplets
(WHO, 2014; Milton, 2020). This somewhat arbitrary size classification implicitly refers to the transmis-
sion modes/mechanisms, namely droplet, and airborne transmission. However, the distinction between
droplet transmission and airborne transmission determined by a simple cut-off in droplet size neglects a
multitude of physical processes crucial to the droplet evolution within an indoor environment. For ex-
ample, droplets that are larger than a selected cut-off size at the source may shrink due to evaporation,
becoming sufficiently small (before any impact occurs) that they then contribute to airborne transmis-
sion. The distinction between droplet transmission and airborne transmission is better explained by
the route of infection. Droplet transmission occurs when a subject is exposed to large (> 5 − 10 µm)
pathogen-laden droplets expelled by an infected person that come into contact with their mucous mem-
branes. Droplet transmission usually occurs in close proximity (see §2.2). While droplets may fall quickly
onto a surface close to the source, aerosols are expected to remain airborne for longer periods and can be
advected away from the source with ventilation flows leading to what we term ‘the airborne transmission
route’. Therefore, an important aspect of understanding droplet and airborne transmission is the size
distribution of the expiratory droplets containing the virus also include water, salts and organic material
(Kumar & Morawska, 2019). Droplets and aerosols produced by violent expiratory events such as cough-
ing and sneezing have been investigated and reviewed by several authors, including Yang et al. (2007);
Bourouiba et al. (2014), Bourouiba (2020) and Mittal et al. (2020). However, under normal circum-
stances, the cumulative amount of expiratory fluid and consequently the droplets and aerosols produced
by low-frequency intermittent events such as coughing and sneezing are less than that of high-frequency
events such as breathing and talking (Gupta et al., 2010).
The studies conducted on disease progression suggest that infectivity of COVID-19 peaks before the
onset of symptoms and consequently, preventing pre-symptomatic and asymptomatic transmission is key
to containing the spread of the disease (Matheson & Lehner, 2020). At the early stage of SARS-CoV-2
infection, upper respiratory tract symptoms and the presence of high concentrations of SARS-CoV-
2 virus in oral fluids are common (Wölfel et al., 2020) which support the recent findings identifying
speech droplets to be a potential cause of transmission (Stelzer-Braid et al., 2009; Anfinrud et al., 2020;
Stadnytskyi et al., 2020).
Conversational speech produces a wide range of droplet sizes (sub-micron up to the order of 100 µm)
which are exhaled at speeds of of the order of 3.5 − 4m s−1 . The reported size distributions of speech
droplets show a large variation, due to different measurement techniques, evaporation of droplets prior to
measurement, and natural variation amongst different people (Xie et al., 2009). Aerosol measurements
capable of measuring particles in the range 0.5 −20 µm indicate that speech droplets form across the
measurement range, with geometric mean diameter of ∼ 1 µm, droplet number concentrations in exhaled
breath of the order of 0.1 −1 cm−3 , and exhaled particle emissions rates of the order or 1 −10 s−1 (Asadi
et al., 2019; Johnson et al., 2011). Asadi et al. (2019) showed that speaking louder is correlated with
higher particle emissions and found that a small fraction of people are ‘super-emitters’, who consistently
release an order of magnitude more particles than others. Chao et al. (2009) measured the droplet size
distribution of cough and speech droplets at mouth opening and found the geometric mean diameter
of cough droplets was 13.5 µm. In contrast, speech droplets were 16 µm, but had a reported maximum
diameter of up to 1000 µm. Xie et al. (2009) reported the average speech droplet diameter to be between
50 − 100µm. Interestingly, this study also showed that both the number and the droplet size increased
significantly when the subjects swallowed food dye solution (with or without sugar) before the experiment,
indicating that eating may promote the release of higher numbers and larger sizes of expiratory droplets.
Although light scattering measures only larger droplets and consequently provides a conservative estimate
of total droplet count, Stadnytskyi et al. (2020) measured high droplet release rates relative to other
studies when using this technique. Both Anfinrud et al. (2020) and Stadnytskyi et al. (2020) showed
that speech droplets of size 10 − 100µm can remain suspended for up to 30 s. Therefore, it is imperative
to appreciate that speech droplets can potentially transmit respiratory diseases by both the droplet and
airborne transmission routes. In contrast, it has consistently been shown that the majority of aerosol
particles in exhaled breath are < 5 µm (Fennelly, 2020), which diminishes the possibility of droplet

6
transmission when breathing; however, airborne transmission cannot be ruled out.
When droplets are exhaled, they evaporate at a rate that depends on droplet size and composition,
and the relative humidity and temperature of the air. Redrow et al. (2011) compared the evaporation
time and resulting nuclei sizes of model sputum, saline solution, and water droplets. They showed
that sputum droplets containing protein, lipid, carbohydrate, salt and water leave larger nuclei than
salt solution. They calculated the time scales of evaporation of water droplets at room temperature,
for relative humidities between 0 to 80%, to be 0.1 − 1 s for droplets less than 10 µm and 7 − 40 s for
100 µm droplets. Therefore, it is expected that droplets larger than 100 µm settle on the floor or other
nearby surfaces (Liu et al., 2017), while droplets smaller than about 10 µm tend to form nuclei and are
transported as passive scalars, i.e. they were transported by airflows without the dynamics of the airflow
being significantly affected (Xie et al., 2007).
The final size of exhalation droplets depends upon many factors including the initial size, non-volatile
content, relative humidity, temperature, ventilation flow, and the residence time of the droplet. Marr
et al. (2019) gave the equilibrium size for 10 µm sized model respiratory droplets containing 9 mg ml−1
NaCl, 3 mg ml−1 protein, and 0.5 mg ml−1 surfactant to be 2.8 µm and 1.9 µm at relative humidities of
90% and < 64%, respectively.
A significant uncertainty in our ability to quantify the relative importance of airborne transmission is
the viral load associated with different aerosol sizes for different expiratory events, at different stages of
infection and the potential for natural variation amongst people. This information is currently unknown,
leading to large uncertainty bounds.

2.1.2 Transmission via surface contacts and fomites

Fomites are inanimate objects that have become carriers of virus particles and these have been shown to
play a role in the spread of viruses. Little is known of the true risk of becoming infected by SARS-CoV-2
through this pathway, as it is difficult to isolate from the droplet and airborne routes, the dose required
to become infected has not been determined and the majority of studies that have looked at its survival
on surfaces have used far greater viral loads than would be deposited naturally (Vasickova et al., 2010).
Knowledge of the virus survival on surfaces and interactions between the fomite and droplet/airborne
routes through deposition and re-suspension of viral particles is nevertheless important in minimising
the risk of infection.
Fomite transmission occurs predominantly from human behaviour through non-infected individuals
making contact with or handling infected objects, which may be infected via deposition of large droplets
from infected individuals or via direct contact by individuals with viral particles on their hands. The
non-infected individual then transfers viral particles from their hands to mucous membranes by touching
their eyes, nose or mouth. Advice given by various groups to avoid unnecessary contact between hands
and objects in public environments, as well as advice to avoid touching one’s face, is sound and should be
encouraged. In China it was found that the majority of surfaces within hospital wards that had infected
individuals, were found to have traces of the virus (Ye et al., 2020), and therefore cleaning of surfaces is
an important mitigation strategy to avoid infection.
This section briefly summarises what is known about SARS-CoV-2 and its survival and transmission
via surfaces. Note that a more thorough and detailed literature review is found in Appendix B of this
document, which details the sources upon which this advice is based.

Factors affecting the survival of SARS-CoV-2 on surfaces. A number of environmental factors


affect the survival of SARS-CoV-2 on surfaces.
• Temperature effects have been reported to be significant, with higher temperatures decreasing
survival times (Dietz et al., 2020). Comfortable indoor temperatures should be maintained and
the use of air conditioning should be minimised wherever practical with the appropriate supply of
outdoor air remaining a priority.
• Humidity has been shown to also have an effect on the virus, with drier conditions being more
suitable for virus survival (Biryukov et al., 2020). While higher humidity is preferable to reduce
viral infection, there are numerous health issues related to high humidity and promotion of mould

7
growth. We therefore advise that in cold weather the relative humidity should be maintained at
between 40–50 %, rather than below 30 %, which is typical of many indoor environments in winter
(Dietz et al., 2020).
• Light is also demonstrated as a method for virus deactivation, with UV-C light being shown to
deactivate other strains of coronavirus Bedell et al. (2016). While the use of artificial light cleaning
technologies is not suggested as an effective replacement for disinfectant cleaning practices, well-lit
rooms, particularly via natural lighting is preferred based on evidence of other viruses (Dietz et al.,
2020; Schuit et al., 2020).
• It is now well-known that SARS-CoV-2 has different survival times on different surfaces, with
laboratory inoculations of SARS-CoV-2 survival rates varying from 3 hours for paper and tissue
to up to 72 hours (3 days) on hard, smooth surfaces such as plastic and stainless steel (and also on
surgical masks) (van Doremalen et al., 2020). Glass and bank notes have survival times in the region
of 3 days, with cloth and wood reported at 2 days. While likely viral loads on contaminated objects
are not known, and hence risk associated with the fomite pathway relative to that for droplet and
aerosol transmission cannot currently be quantified, we believe it is important to regularly clean
often-handled objects and surfaces in public spaces.
Cleaning recommendations. The above leads to the recommendation that it is important to fre-
quently clean door handles, classroom and meeting room desks, tap handles, swing door handles, ticket
machines, pin code keypads, communal office kitchens, etc. Providing point-of-contact public alcohol-
based disinfectant, as is now common on university campuses, shops and public transport is an effective
mitigation strategy to ensure that public spaces are less likely to become contaminated. We conjecture
that an effective mitigation strategy for certain public spaces that involve fomites, such as public com-
puter laboratories found in universities or libraries, would be to encourage users to clean the workspace
(keyboards, mouse, desk and hands) before and after use. Further research is needed to establish the
efficacy of such interventions depending on the frequency of cleaning and in comparison (or in combi-
nation) with other mitigation approaches such as handwashing. The wearing of face coverings will also
reduce droplet deposition on the workspace.
Disinfectants based on alcohols (ethanol, 2-propanol, 2-propanol with 1-propanol) as well as other com-
mon disinfectants (glutardialdehyde, formaldehyde, and povidone iodine (0.23%–7.5%)) are very effective
against SARS-CoV-2 and come highly recommended (Kampf et al., 2020). UK Government advice to use
soap and water to clean surfaces may not be the most effective since soap and water alone was not shown
to deactivate the virus after 5 minutes, however if accompanied by scrubbing this may be more effective
at its physical removal (Kampf et al., 2020). Sodium hypochlorite requires a concentration of at least
0.2%, whilst hydrogen peroxide requires a concentration of at least 0.5% and must be left incubating for
at least 1 minute.

2.2 Social distancing indoors

Social distancing describes the effort to ensure that individuals remain separated by a particular distance
and is often recommended primarily to reduce the transmission of disease via the droplet route. The
quantification of an appropriate social separation/distance to avoid droplet transmission is often based on
research by Wells (1934). His model for disease transmission considered droplets produced by sneezing or
coughing to behave ballistically, with no interaction between them; i.e. droplets would fall from the height
they were produced to the floor (∼ 2 m vertically), while simultaneously evaporating. In spite of the
evaporation process, so called ‘large’ droplets would reach the floor; meanwhile so called ‘small’ droplets
would evaporate quickly leaving relatively ‘dry’ aerosol particles known as droplet nuclei. Wells proposed
two mechanisms for infection: droplet transmission due to large droplets and airborne transmission due to
small droplets that evaporate sufficiently to become suspended in the air for long times. Wells calculated
a cut-off between small and large droplets as 100 µm (not 5µm, as is often cited).
Wells’ falling-evaporation curve has been used to propose a social distancing rule by considering how far
large droplets travel horizontally as they fall. The total distance travelled by a droplet is determined by
its initial horizontal velocity, and also whether it is contained in a coherent flow structure caused, for
example, by coughing or sneezing (Bourouiba, 2020). Small droplets fall more slowly than large droplets,
so travel further, but they take less time to evaporate. The size of the largest droplet that totally
evaporates before falling 2 m is identified, then the horizontal distance this droplet travels is calculated

8
and used to define a social distancing rule. For example, for droplets expelled at 10 m/s (typical for
coughing) this distance is 2 m, while droplets expelled at 1 m/s (breathing) this distance is less than 1
m (Xie et al., 2007).
In addition to the work of Wells, the experiments by Jennison (1941) have also been used as evidence
for social distancing of 1-2 m. Jennison used high-speed photography to examine the fall of droplets
produced by talking, coughing and sneezing, concluding that the majority of the droplets fell to the
ground within 1 m (the field of view for the experiments). However, no details were provided about how
this conclusion was reached and it was acknowledged that the experimental method was not sensitive
enough to capture all the droplets, tending to select for larger droplets (Bahl et al., 2020).
The Wells model and many of its extensions assume that droplets behave independently of each other,
travelling ballistically. However, more recent research has shown that this is often not a good assumption.
Experimental studies of coughing and sneezing show that exhalation results in a puff of warm, humid
air that influences the distance travelled by groups of droplets (Bahl et al., 2020). Experimental images
show that the turbulent gas cloud emitted from a human sneeze can travel 8 m, carrying particles along
with it (Bourouiba, 2020). These results suggest that for coughing and sneezing, the exhalation or puff
needs to be taken into account in calculating the maximum distance travelled by droplets. Moreover,
consideration of these images highlights that violent respiratory events have significant directionality and
in contexts where the direction of these events can be inferred then this should influence the layout of
desks, etc., within classrooms and offices.
Current social distancing advice aims to reduce droplet transmission, however social distancing can
also reduce transmission by small droplets, as aerosols are diluted with distance from the source (Chen
et al., 2020). The suggested distance of 2 m is based on a model that assumes ballistic droplets, rather
than particles that travel within an exhaled puff that dilutes with distance. Further research is needed to
identify an appropriate distance at which sufficient dilution has occurred. This distance will be influenced
many factors, including the nature of the exhalation (breathing, talking, coughing, etc.), the properties
of the air (humidity, temperature), the droplet size distribution, the virus concentration with droplet
size, and the size of the infectious dose.
There is increasing evidence that airborne transmission of SARS-CoV-2 is significant (e.g. Morawska
et al., 2020; Fennelly, 2020). Outdoors, in well-ventilated indoor spaces, and for short interaction times,
social distancing will reduce airborne transmission. However, for longer exposure times and/or in poorly
ventilated spaces, social distancing is unlikely to be sufficient as the dilution at room scale will not
reduce the aerosol concentration enough to avoid an infectious dose. This emphasises the importance of
additional measures, such as good ventilation and face coverings.

2.3 Guidance on face masks and coverings

There is substantial evidence that face masks and coverings can lessen the spread of COVID-19 by
reducing the emissions of virus-laden particles, both droplets and aerosols (Leung et al., 2020b) from
the wearer. Moreover, it has also been shown that face masks and coverings may also be protective
by reducing the dose of SARS-CoV-2 received by the wearer. Face shields might prevent the escape of
droplets from the user, as well as similarly protecting the user and providing some limited protection to
the eyes, but they are unlikely to stop the transmission of aerosols (the airborne route) unless used in
conjunction with a face mask or covering. The collated evidence presented within this section has been
gathered from studies across the world and represents the most recent understanding of the subject, as
presented by a cross-section of peer-reviewed papers and scholarly works.
In short, the use of face masks and coverings can reduce the spread of COVID-19 indoors; this is especially
pertinent in settings where there is decreased physical distancing: such as shops, public transport or in
work environments. However, the impact of wearing face masks or coverings on the intended interactions
and activities should be carefully considered with members of disadvantaged or vulnerable groups given
due attention.

9
2.3.1 A summary of the evidence base for the use of face masks and coverings

A systematic review and meta-analysis of distancing, face masks and eye wear in Lancet from June
2020 concluded that “face mask use could result in a large reduction in risk of infection, with stronger
associations with N95 or similar respirators compared with disposable surgical masks or similar (Chu
et al., 2020)”. They also noted that “transmission of viruses was lower with physical distancing of
1 m or more” and “eye protection also was associated with less infection”. These reviews were in both
health-care and non health-care settings. A more recent meta-analysis from August presented significant
results, “that face masks protect populations from infections and do not pose a significant risk to users”
(Ollila et al., 2020).
Masks often refer to surgical or respiratory masks (respirators) that medical staff use, whereas face
coverings encompass broader types and materials such as homemade cloth masks, but may include just
a simple scarf (The Royal Society, 2020a).
Leung et al. (2020b) “Demonstrated the efficacy of surgical masks to reduce coronavirus detection and
viral copies in large respiratory droplets and in aerosols”. Their results suggest that these masks could
prevent transmission of viruses from symptomatic (and for COVID-19 pre-symptomatic/asymptomatic)
individuals.
There is evidence that face masks and coverings may be effective at reducing COVID-19 cases across
the world. Mitze et al. (2020) stated “after face masks were introduced on 6 April 2020, the number
of new infections fell almost to zero” in the city of Jena, Germany; concluding “that the daily growth
rate of COVID-19 cases in the synthetic control group falls by around 40 percent due to mandatory
mask-wearing relative to the control group”. Similarly, “from epidemiological data, places that have
been most effective in reducing the spread of COVID-19 have implemented universal masking, including
Taiwan, Japan, Hong Kong, Singapore, and South Korea” (Prather et al., 2020).
“Our analysis reveals that the difference with and without mandated face covering represents the de-
terminant in shaping the trends of the pandemic worldwide. Zhang et al. (2020) conclude that wearing
of face masks (or coverings) in public corresponds to the most effective means to prevent inter-human
transmission, and this inexpensive practice, in conjunction with extensive testing, quarantine, and con-
tact tracking, poses the most probable fighting opportunity to stop the COVID-19 pandemic, prior to
the development of a vaccine.”
“The benefits face masks could offer as a non pharmaceutical intervention were investigated using math-
ematical models and show that face mask use by the public could make a major contribution to reducing
the impact of the COVID-19 pandemic” Stutt et al. (2020). They demonstrated that mask (and face
covering) wearing can reduce transmission, with high rates of adoption likely to reduce the R0 value to
below one.
As of the 5th June 2020 the WHO (2020) has recommended the wearing of face masks and coverings for
communities and circumstances, where there is risk of transmission and in areas where physical distancing
cannot be achieved, for the “potential benefit for source control” of COVID-19 virus. More recently (in
August 2020) the WHO have released a video to advise the wearing of face masks or coverings.
The Royal Society (2020b) DELVE Initiative reported that “asymptomatic (including pre-symptomatic)
infected individuals are infectious” and “respiratory droplets from infected individuals are a major mode
of transmission”. Reporting that masks reduced droplet dispersal and “cloth-based face masks reduce
emission of particles by variable amounts”, similar to the percentage reductions reported (of viral, bac-
terial and dust particles) by surgical masks. In a more recent study, key findings were that cloth face
coverings are effective in protecting the wearer and those around them and that face masks and coverings
are part of ‘policy packages’ that need to be seen together with other measures such as social distancing
and hand hygiene (The Royal Society, 2020a).
The physics of particle capture by the materials of face masks is complex, it also recognised these
mechanisms will be at play in face coverings. However, coverings (and face masks), as well as reducing
the airflow which can distribute the virus, may simply prevent transmission by stopping the evaporation
of droplets their escape to become droplet nuclei (Leung et al., 2020a).
Face masks and coverings may also protect the wearer, to different degrees of effectiveness. The material
and the make-up of the face mask or covering is important for the filtration efficacy. Wilson et al. (2020a)
modelled the risk of transmission based on published data on the effectiveness of various material against

10
a viral challenge; these included FFP2 (N95) respirator material (at 95% efficiency), with surgical mask
material slightly less efficient. A vacuum cleaner bag (83%) was found to be the most efficient household
material and a scarf (44%) the least efficient. In between these two materials were a tea towel, cotton
mix, linen, a pillowcase, silk and 100% cotton T-shirt.
User protection is discussed by Gandhi et al. (2020) who hypothesise that “universal masking reduces
the ‘inoculum’ or dose of the virus for the mask-wearer, leading to more mild and asymptomatic infec-
tion manifestations.” They state numerous cases where universal masking led to fewer cases, or more
asymptomatic cases as opposed to comparative examples, whether this was in animals, on cruise ships,
meat factories, or regions of universal mask wearing. “Countries accustomed to masking since the 2003
SARS-CoV pandemic, including Japan, Hong Kong, Taiwan, Thailand, South Korea, and Singapore, and
those who newly embraced masking early on in the COVID-19 pandemic, such as the Czech Republic,
have fared well in terms of rates of severe illness and death.”
The use of face shields as an alternative to face masks and coverings within the service industry in the
UK is popular, it is also of great benefit to those of hard of hearing (HoH). “Face shields can substantially
reduce the short-term exposure of health care workers to large infectious aerosol particles, but smaller
particles can remain airborne longer and flow around the face shield more easily to be inhaled.” Lindsley
et al. (2014). Thus their use might prevent the escape of droplets from the user, as well as similarly
protecting the user and providing some limited protection to the eyes. They are however, unlikely to stop
the transmission of aerosols (the airborne route), without being used in conjunction with a face mask or
covering. Verma et al. (2020) visualised the flow around a face shield (and respirators with valves) and
noted “that although face shields block the initial forward motion of the jet, the expelled droplets can
move around the visor with relative ease and spread out over a large area.” Similar results were found
for respirators with exhale valves, with aerosols escaping through the valve.
Any covering of the face negatively impacts the hard of hearing (HoH), with close to 11 million people in
the UK who are HoH (around 1 in 6 people). Where possible, it would be prudent to adapt the guidance
on face masks to accommodate them, as the usage of face masks may hinder the ability to listen and
lip-read. An effective strategy to accommodate those HoH is to use clear face masks (Grote & Izagaren,
2020), or the use of novel technologies such as captioning apps.
Finally, the application of the precautionary principle suggests that people should be encouraged to
wear face masks and coverings on the grounds that, in many circumstances, we have little to lose and
potentially something to gain from this measure. Greenhalgh et al. (2020) said that “masks are simple,
cheap, and potentially effective . . . and outside the home in situations where meeting others is likely
(for example, shopping, public transport), they could have a substantial impact on transmission with a
relatively small impact on social and economic life.”

2.4 Source reduction through timetabling and purging between events

Airborne infection risk is reduced when the ventilation provision of outdoor air is maximised. Operating
the existing indoor environment conditioning and controlling equipment in a manner that fixes the
outdoor air supply rate to be maximal (with due consideration to the practical limits for a comfortable
indoor environment), the airborne risk can be greatly reduced by lowering occupancy in a given indoor
space. For example, should the ventilation plant be kept running at the same level (i.e. unchanged
absolute outdoor air supply rate) and the occupancy halved (e.g. through week in – week out working)
in an indoor space then the chances that infection occurs within is approximately halved.
Where reductions to the absolute levels of occupancy are impractical then some change of timetabling
should be considered. Where possible, attendance should be extended by some occupants arriving
and leaving earlier than usual with other occupants arriving and leaving later than usual. Moreover,
consideration should be given to purging rooms between meetings, classes and events. This would require
the room to be unoccupied between consecutive events during which period all possible efforts are made
to increase the outdoor air supply rate (whether by opening windows, doors and ventilation systems).
At the end of the purging period it is best if the room is cleaned in the manner detailed in §2.1.2
to minimise the chance of spread to the next occupants. It is highly likely that the greatest rates of
decay in the concentration of virus-laden particles will occur at the start of the purging periods. So
any purging duration is better than none as long as the increased ventilation flows are given time to
establish themselves. That said, the longer the purging duration then the lower will be the resulting

11
concentration levels. To establish how effective these purging strategies may be, a simple ‘room-change’
time scale can be calculated by dividing the volume of the space by an estimate of the rate of outdoor
air supply during purging; note that the room-change time scale, in hours, is simply the inverse of the
air changes per hour (AC/hr). Melikov et al. (2020) report the intake fraction (the proportion of air
exhaled by the infected person that is then inhaled by another occupant) for various purge scenarios.
They quantified the reduction in intake fraction for ventilated cases with purging periods (of between
15 min and 30 min) which were in the range 0.2–1.8 room-change time scales. They went to consider cases
of increased ventilation rates which led to purging times (15 min) being around 5.5 room-change time
scales. Their conclusions included the suggestion that periods of constant occupation should be short
with appropriately long breaks being recommended; break durations of 10–20 min were recommended
for occupancy durations of 30–45 min for classrooms, meeting rooms, conference rooms, etc....
In summary, wherever possible occupancy should be reduced (by remote working and/or reduced occu-
pancy), additionally unoccupied periods should be introduced at regular intervals throughout the day
during which the space should be purged and after which the space should be cleaned. Risk-based
calculations are needed to determine the optimal purging times.

2.5 The influence of occupancy behaviour on indoor air movement: impli-


cations for the spread of COVID-19

The movement of people within enclosed spaces leads to considerable disturbance of the air and any
airborne aerosols. Although aerosols greater than about 10 micron settle from the space relatively
rapidly and so they may be dispersed by people movement, smaller aerosols (e.g. < 5 µm) which can
remain airborne for several 10’s of minutes may be much more strongly affected by such dispersal. This
dispersal may in fact dominate other dispersal processes if there is a sufficient frequency of people passing
through a space. People have widths typically in the range 0.3 − 0.5 m, and move at speeds of 1 − 2 m/s
even when walking, and this leads to a highly turbulent wake with Reynolds number of about 100, 000.
The mixing associated with this wake in corridors, supermarket aisles, meeting rooms, school classrooms
or other spaces with relatively high people density and movement (even with 2 m spacing) may be key
for quantifying the aerosol dispersion prior to it being ventilated or settling out from the space. Indeed,
with ventilation timescales of 10 − 20 minutes in typical buildings, with 5 − 10 air changes per hour, and
the settling time of small aerosols (<10 µm) being of comparable duration, the aerosols may be mixed
by the wakes of many people. For example, in a supermarket, with one person moving down an aisle
every 10 − 30 s, a cloud of infected aerosol may be mixed by the wakes of between 20 − 120 people. This
mixing leads to a more uniform, but smaller concentration of aerosol in space, thereby increasing the
risk of exposure to some aerosol for the subsequent people that pass by the aisle, although the amount
of aerosol may be smaller; the associated risk of infection from any virus in these aerosols depends on
dose and hence the amount of aerosol to which they are exposed (Bhamidipati & Woods, Under review).
Laboratory simulations of the dispersal of both clouds of dye and suspended particles have been carried
out in a fluid-filled channel of size 1.04 m × 0.10 m × 0.20 m, as a model of a corridor. To model the
movement of people, cylinders of radius 0.015 − 0.050 m were moved back and forth along the channel,
with speeds of 0.1 − 0.2 m/s, thereby providing a dynamically similar flow regime for the full-scale flow
of people’s wakes. This models the mixing of the dye or cloud of particles along the channel. Data
shows that the motion of the cylinder leads to an effective dispersion coefficient for the along-channel
mixing, which provides the basis for a theoretical model (Mingotti et al., In press). In experiments with
a background ventilation along the corridor, in addition to the people-driven mixing, a dilution wave
migrates along the corridor after the release of infected aerosol along the corridor, but the dispersion
associated with people movement causes the aerosol to mix back upstream into the dilution wave, delaying
the effectiveness of the ventilation (Mingotti & Woods, In prep.). In figure 1(a, b), images at successive
times from an experiment illustrate the dispersal of a cloud of dye along the channel. In figure 1(c), the
concentration data from a number of experiments collapse to a simple model for the dispersion.
Scaling up to a building, we find that the typical mixing rates associated with people in a corri-
dor/supermarket aisle depend on the frequency of passage of people. With a person walking along
the corridor/aisle every 10 − 40 s (Choudhary et al., 2010; de Wijk et al., 2018), this corresponds to a
dispersion coefficient in the range 0.05 − 0.2 m2 /s (Mingotti et al., In press), so that over a period of
600 − 1200 s, airborne aerosol may spread about 5 − 15 m along the corridor.

12
Figure 1: (a, b) Images show the depth-averaged concentration of a cloud of dye in a laboratory tank.
This evolves in time owing to the mixing produced by the repeated motion of a cylinder, representing
movement of people in a corridor. In (a), pictures of the tank are shown as captured during an experiment.
In (b), false colours are used to represent the dye concentration field in each of these pictures, with red
being the maximum concentration and blue showing absence of dye. The white rectangle on each image
in (b) illustrates the position of the cylinder at that time. (c) Collapse of the experimental data of
the depth-averaged dye concentration to a continuum model of the concentration of the dye along the
channel. The y axis shows the dimensionless concentration, at each time scaled relative to the theoretical
value in the centre of the channel at that time, and the x axis shows the dimensionless distance along
the channel, scaled with the predicted diffusive spreading along the channel at each time (after Mingotti
et al., In press).

Figure 2: Image showing the mixing of individual clouds of infected aerosol, dyed different shades of red,
and normalised relative to the initial concentration as seen on the legend. The corridor is 5 m wide (y
axis) and 20 m long (x axis), with people (blue dots) moving from left to right along the corridor. In
this simulation, the along-corridor people spacing is 2 m and they move with speed 1.5 m/s, while the
clouds of aerosol are produced by one person moving down the corridor, so the older cloud at the left
hand end of the corridor is more dispersed than that on the right (after Bhamidipati & Woods (Under
review)).

13
Bhamidipati & Woods (Under review) developed a simple computational model for the dispersal of
aerosols in a building by a stream of individual people moving through a building, modelling the detailed
mixing produced by each person. This has led to a series of simulations of the dispersal of clouds of
aerosol as people pass along a corridor. Figure 2 shows the concentration of aerosol with time, over a
period of 15 s as an infected person walks down a corridor breathing out. A series of local clouds of
aerosol-laden air are breathed out by the infected person, and these are then dispersed owing to the
mixing produced by the continuing stream of people following in the wake of the infected person.
Models of different building types are under continued development, but the key result is the efficacy
of mixing produced by the movement of people, which can lead to widespread dispersal of small aerosol
produced by an infected person. This has leading order implications for the occupancy levels in shops
and in the corridors of classrooms and offices in terms of the risks of exposure to the small aerosols due
to the repeated passage of people. The combination of aerosol settling and ventilation of the air from the
space typically leads to a residence time of the small aerosols of several tens of minutes; if these small
aerosols are present in sufficient numbers to play a role in infection transmission, which depends on the
source strength (i.e. the number of infectious people present), and the residence time (i.e. as regulated
by the ventilation rate), then the continued presence of the infectious and healthy people may provide a
pathway for transmission.
Further experiments have been carried out in several operational buildings in which localised dilute
clouds of CO2 are released at a point in a room or corridor, and the subsequent spreading of this cloud
is then measured over time; the CO2 acts as an analogue for the small aerosols in that it moves with
the air flow in the space (Woods et al., Under review). Comparisons have been made between the rate
of dilution and flushing of the CO2 from the space in the case with people moving and with no people
moving in the space. In the example of a ventilated corridor, for example, the impact of the people
moving along the corridor is to drive additional mixing of the cloud of CO2 into the new ventilation air,
thus delaying the flushing of the CO2 from the space. This illustrates how the internal mixing processes
of the air in buildings, and especially people movement, can lead to greater residence times for small
aerosols (Woods et al., Under review). To mitigate the risks of these small aerosols, potential solutions
include increasing ventilation rates, reducing the duration of exposure, and reducing the source of the
aerosols by reducing occupancy levels and through the use of face masks.

3 Ventilation and the airborne transmission route


The adequate ventilation of a building space should be regarded as the primary mitigating measure
against the spread of airborne diseases. In temperate climates this leads to the simple advice that all
ventilation (by which we refer exclusively to the supply of outdoor, or suitably sterilised or filtered, air)
systems be operated to maximise supply and ventilation openings (e.g. windows, vents, louvres, doors,
etc.) be opened to the extent permitted by design. However, in colder periods (like the British heating
season) there is a conflict between reducing airborne infection risk, by increasing the outdoor air supply,
and maintaining occupants thermal comfort and reducing energy consumption and the associated costs.
In this section we seek to provide guidance to resolve this conflict.
In order to precisely quantify the risk of airborne infection occurring it is necessary to determine oc-
cupants’ exposure to airborne virus particles. To do so rigorously is challenging (often to the point of
impracticality see §3.1) and thus it is wise to focus efforts on estimating the likelihood, perhaps better
the change in likelihood, that airborne infection may occur within a space under a number of scenarios
under the assumptions made.

3.1 Towards an understanding of ventilation and COVID-19

Ventilation, i.e. the supply of outdoor air, dilutes any pollutants produced indoors — including viable
airborne virus particles. This dilution is dominated either: by the incoming outdoor air mixing with the
existing indoor air, with then further mixing occurring as the air is transported through the building space
before the ultimate evacuation outdoors; or by seeking to introduce the outdoor air into the occupied
zone of the building space in a relatively unmixed state and then ‘displace’ any air polluted by airborne
virus particles back outdoors (e.g. Bolster & Linden, 2008a,b; Mingotti & Woods, 2015a,b). Irrespective

14
of the intended strategy, mixing will occur inhomogeneously within the building space which results in
unpredictable distributions of virus particles. Moreover, differences in temperature between indoor and
outdoor air and the production of heat within the building space (every occupant outputting ∼100 W of
heat) exacerbate the complexity of indoor air flows and increase the unpredictability of the distribution
of airborne virus particles. Finally, in all indoor spaces (perhaps excluding COVID-19 hospital wards) it
is unknown if there are any infectious occupants (the sources) and where they might be located. As such,
trying to predict the distribution of viral contamination, for example using normal exhaust ventilation
design techniques (which require knowledge of the source location and rate of contamination) is likely to
be futile. Therefore estimating the risk of infection via modelled data typically requires the assumption
that the distribution of airborne virus laden particles is relatively uniform irrespective of reality. We
note that in the case that ‘dead’ or ‘stagnant’ zones can be expected or evidenced within an indoor space
then further considerations are required see, for example §4 for further discussion.
As such, the critical input pertaining to the control of the environmental quality for any model estimating
airborne infection risk within an indoor space is the bulk supply of outdoor air, or ventilation rate per
person which we denote Q. However, outdoor air may enter an indoor space via a ventilation system,
windows, doors, vents, cracks in the building fabric or, indeed, though the very fabric itself (i.e. many
building materials, e.g. bricks, are porous). As such, there is significant scope for both intentional
and unintentional supply of outdoor air. Directly measuring the air flow through all of the potential
pathways for any given indoor space is challenging. Pressure testing can be used to measure infiltration
rates but cannot assess the ventilation rates in operational settings and does not help with individual
spaces or zones. For purely mechanically ventilated, well-sealed, buildings it may be tempting to assume
the intended outdoor air supply is actually achieved; however, such an assumption is not without risk.
Measurements of the actual air flows could be made in the duct work but these are not without their
own challenges (the velocity profiles of air flows in the these typically tortuous ducts is a challenging
area of fluid mechanics in its own right) .
In most indoor environments the dominant source of CO2 is human activity and the level of CO2 in
outdoor air remains broadly constant (at about 400 ppm). As such, it may be tempting to try to infer
outdoor air supply (ventilation) rates by monitoring CO2 . However, whilst CO2 is an excellent proxy by
which to determine indicative levels of ventilation, rigorously determining the precise (typically transient)
outdoor air supply rate is non-trivial (e.g. see the appendices to Burridge et al., Under review).
Crucially, Rudnick & Milton (2003) established a methodology, based on the Wells-Riley model (Wells,
1955; Riley et al., 1978), which takes monitored CO2 data (the equipment to do so costing less than a
couple of hundred pounds per sensor) and directly infers the risk of airborne infection without the need
to assess/assume the ventilation rate (nor does it require the space to be in steady-state). Their model,
assuming the presence of an infector, can be parameterised for any airborne disease to provide both the
likelihood of infection and the reproductive number (or R-number, i.e. the average number of infections
arising from a single infectious case) for indoor spaces over time periods selected such that the space
remains constantly occupied.
In addition to the monitored CO2 , the risk reported by Rudnick & Milton (2003) depends strongly on
the time period of assessment, the occupancy level, the nature of the virus, and occupancy activity —
the latter two aspects being parameterised via the rate of generation of infectious quanta q per person
(usually expressed in quanta per hour). Wells (1955) conceived the idea of a quantum (or infectious dose)
in an effort to describe the stochastic behavior of airborne infection, and values for the quanta generation
rate have been derived for SARS-CoV-2 (e.g. Buonanno et al., 2020a). However, just as for most other
airborne diseases, there is wide variation in the values relevant for an infectious individual depending on
a) their activity level, b) the viral load in their sputum and c) the ratio between one infectious quantum
and the infectious dose.
Buonanno et al. (2020a) report that in typical scenarios with low activity levels, q ≈ 1 /hr may be
appropriate for COVID-19. Buonanno et al. (2020a) further suggest that should an individual be vo-
calising (in a manner not dissimilar to talking) whilst carrying out light exercise (e.g. walking) then
values as high as q ≈ 100 hr can be inferred — for offices occupied and ventilated at appropriate levels
(e.g. ∼ 10 m2 per occupant and the outdoor air supply per person is Q ≈ 10 l/s/p CIBSE, 2015) then
for occupancy periods of constant occupancy of, say, four hours the R-number for the office (assuming
a floor-to-ceiling height of between 3–4 m) would be around 4, i.e. from a single infector then four new
COVID-19 infections would result. For more typical behaviour in an office, i.e. most occupants carrying
out desk work with a few talking relatively quietly for which q ≈ 1 /hr, then even assuming the office

15
R-numbers, RA Q = 4 l/s/p Q = 10 l/s/p Q = 20 l/s/p
q = 0.3 /hr 0.25 0.13 0.07
q = 1 /hr 0.84 0.42 0.24
q = 5 /hr 4.0 2.1 1.2

q = 20 /hr 14 7.6 4.4


q = 100 /hr 35 26 18

Table 1: COVID-19 R-numbers, RA , calculated over the period that a pre/asymptomatic person remains
attending work in an open-place office (floor plan of 400 m2 and floor-to-ceiling height of 3.5 m) occupied
by 40 people for 8 hrs each day (see Burridge et al., Under review).

remains constantly occupied for a full nine hour day, R-numbers of around 0.1 are obtained (these rise
to around 0.2 if the office is poorly ventilated, i.e. Q = 4 l/s/p, and drop to around 0.06 if the ventilation
is doubled).
The results of Buonanno et al. (2020a) take a value of q = 142 /hr and show the airborne infection
risk for various public indoor spaces (namely, shops and restaurants), reporting R-numbers for differing
exposure scenarios (changing outdoor air supply and occupancy scenarios) which they describe as before
and after ‘lockdown’ (N.B. they do not report values for restaurants after lockdown). They select
modelled durations of ∼ 3 hrs. For poorly ventilated spaces Buonanno et al. (2020a) report R-numbers
ranging from 2 ≤ R ≤ 50 before lockdown (1.7 l/s/p ≥ Q ≥ 0.2 l/s/p) and after lockdown 0.1 ≤ R ≤ 0.8
after (10.5 l/s/p ≥ Q ≥ 5.2 l/s/p). For better ventilated spaces then 1 ≤ R ≤ 6 (10 l/s/p ≥ Q ≥ 4.5 l/s/p)
before lockdown and afterwards 0.1 ≤ R ≤ 0.4 (55 l/s/p ≥ Q ≥ 22 l/s/p).
Since an occupant can become infected at any point on any given day then taking any particular duration
seems and arbitrary choice which, for the most part, is hard to justify. Burridge et al. (Under review)
point out that for indoor spaces which are regularly/consistently attended by the same/similar group of
people (e.g. open-plan offices or some school classrooms, and herein a ‘regularly attended space’) one
should consider the likelihood of infection over a period during which an infectious person may remain
pre/asymptomatic. For COVID-19 this period is currently estimated to be between five and seven days.
They developed simple extensions to the work of Rudnick & Milton (2003) which enabled variations in
occupancy behaviour and activity to be accounted for and the likelihood of infection to be assessed from
monitored CO2 . In doing so, Burridge et al. (Under review) calculate the likelihood that an indoor space
contributes to the spread of COVID-19 by assuming that a single pre/asymptomatic infector regularly
attends the space and ceases to do so once they show symptoms reporting the absolute R-number, RA ,
for modelled and monitored spaces.
As shown in table 1 for typical behaviour in a typical office Burridge et al. (Under review) report
RA ≈ 0.5 which rises to RA ≈ 0.8 for a poorly ventilated space (Q = 0.4 l/s/p) and falls to RA ≈ 0.2
if the ventilation is doubled — which are reassuringly below one, thereby suggesting that the return to
desk-based office work is unlikely to contribute significantly to the COVID-19 spread. However, should
most of the office remain sedentary but start vocalising (akin to a call-center, or similar) then RA ≈ 2 —
highlighting the importance of occupancy behaviour in determining whether or not a particular indoor
space contributes to the spread of COVID-19 or not. Burridge et al. (Under review) also present results
for the airborne infection risk from CO2 data monitored within an office with uncontrolled natural
ventilation. The particular office is not of a modern well-sealed design. The risk levels within that
monitored naturally ventilated office remain comparable with the modelled office, intended as being
‘typical’, therein. However, the airborne infection risk was calculated for periods when the windows
were opened and for those when the windows remained shut — the risk of infection was approximately
doubled when the windows remained shut. This provides quantitative support for the guidance that
where practical ventilation openings (like windows, doors, etc.) should be opened, but doing so is not
without conflict, see appendix A.
Such findings beg the question: how might the infection risk vary between seasons as weather changes
from being typically temperate and what might this mean for the spread of COVID-19 in winter 2020?
Vouriot et al. (In Preparation) examined the R-number within various spaces inside schools. Their most
meaningful results are for classrooms, which can be regarded as regularly attended spaces, where they
reassuringly find R-numbers below one if pupils are assumed to be carrying out desk based learning in
a relatively calm/quiet environment and quanta generation of q ≈ 1 are appropriate. The R-numbers

16
Figure 3: The variation in the absolute R-number, RA , during the period 25th May 2019 to 20th July
2020 determined from monitored CO2 and the school’s occupancy timetable for a typical classroom
within a relatively modern build school (rebuilt in September 2016). The shaded regions correspond to
holiday periods. For data recorded during the summer term of 2019 the average was RA = 0.35, for the
autumn term of 2020 the average was RA = 0.53, and for data recorded during the spring term of 2020
the average was RA = 0.63 until the lockdown of 20th March.

rise to 1.5 ≤ RA ≤ 3.8 if one assumes values of q ≈ 5 which are more appropriate if the class is carrying
out more vocal activities and they rise further still if one assume pupils are actively moving around the
classroom. Crucially, in all cases, the greatest R-numbers are obtained during colder winter months
(for example, November to February) — being typically around 80% greater than those estimated for
more temperate months (i.e. May to September). We see no reason not to expect similar trends in the
reproductive number of indoor spaces beyond schools and such convictions underpin our guidance to
assess and ideally monitor ventilation provision in order to understand the needs for modification and
the implementation of other measures.

3.2 Ventilation guidance for winter 2020

A concern for the northern hemisphere winter is that buildings will become less well ventilated, with
a lower supply of outside air in order to maintain warm conditions indoors. Ventilation systems that
recirculate a proportion of the indoor air, primarily to temper the temperature of the outdoor air without
increasing energy consumption, are common but it is crucial to regard only the flow of outdoor air as
contributing to the ventilation rate (see appendix C.3 for more detailed discussion). We recommend
evaluating the benefits of increased monitoring of the indoor environment, especially indicative outdoor
air supply rates via CO2 levels. CO2 levels not exceeding 1000 ppm within an indoor space broadly indi-
cating that outdoor air supply is likely to be adequate for offices and mechanically ventilated classrooms
(i.e. Q ≈ 10 l/s/p), with the equivalent level being 1 500 ppm in naturally ventilated school classrooms
(i.e. Q ≈ 5 l/s/p, see Annex A of DepartmentforEducation, 2018a, for a full discussion). Doing so
will assist in: a) highlighting high-risk spaces for which mitigation measures need to be considered (e.g.
enhanced ventilation provision to manage certain activities or some of those measures detailed in §4),
and b) helping obtain the quantitative evidence to reassure occupants as to their relative safety. Where
monitoring of CO2 is undertaken, consideration of the build-up and decay of CO2 , and the variation
in CO2 levels within the space can provide additional insights; where experience or skills are lacking,
engagement with a professional building services engineer would be beneficial. We note that the design of
school classrooms will, in some cases, have been carried out allowing CO2 levels to reach up to 2 000 ppm
for brief periods; as Vouriot et al. (In Preparation) show, this does not necessarily indicate unacceptable

17
risk levels for COVID-19. Moreover, active management of a classroom’s windows and other ventilation
openings may enable these high peaks to be avoided or minimised, appendix A provides discussion of
strategies to do so in winter without excessively impacting occupant thermal comfort.
Where people are brought together in moderate to high densities for significant portions of the day
and no monitoring is intended, we recommend that the design provision for ventilation of the indoor
space be investigated to determine whether adequate ventilation is likely being achieved. Consideration
should be given to installation and the subsequent maintenance to estimate whether or not the design
provision might realistically be attained. Where the design provision is unavailable, efforts should be
made to ‘reverse engineer’ an understanding of the ventilation. In the absence of knowledge as to the
number of infected occupants, ventilation provision should always be considered per capita based on the
design occupancy — we ventilate buildings for the sake of the occupants. Decreasing occupancy density
should be considered both to minimise transmission via the droplet route, the fomite route (see 2.2)
and, crucially, the airborne route as the per capita ventilation provision from fixed systems/plant can
be drastically increased without new investment (see 2.4). Where ventilation rates meet existing design
guidance the expected risk of airborne infection might be regarded as low. In the absence of monitoring,
consideration should be given to potential stagnant zones within indoor space (e.g. a sheltered reading
corners or break-out spaces); where suspected these should be addressed (see 4).
Where CO2 monitoring is carried out, sensors should be placed at heights and locations within the
space representative of the breathing zone. Where practical, occupancy and excess CO2 (i.e. CO2
above outdoor levels) should be recorded and simple calculations undertaken to estimate the level of
risk to occupants (see, e.g. Burridge et al., Under review) — we expect that, in the most part, these
calculations will prove simply reassuring. Where no calculations are desired, then for given activity
within a space, it is worth noting that the airborne infection risk depends directly on the excess CO2
relative to the number of persons responsible for producing it — this latter quantity being impossible
to evaluate without monitoring (in which case the simple calculations of Burridge et al. (Under review)
may prove more useful). In all cases, we suggest that consideration not only of risk but also the rate at
which the risk is increasing with time is prudent. The relative rate of increase in airborne infection risk
is directly proportional to the ratio of the instantaneous values excess CO2 and current occupancy (see
Burridge et al., Under review). These values are easily obtained and indicate the level of risk that will
be realised should all else remain equal.
We note, however, that ventilation flows are complex and may involve air flow from one space in a
building to another. They are also strongly influenced by the locations of openings and the strength of
internal heat gains. Further work on the implications of these effects is needed.
Finally, we conclude that the risk of COVID-19 being spread by the airborne route is not insignificant,
varies widely with activity level and environmental conditions (which are predominantly determined by
the bulk supply of outdoor air), and are expected to increase in winter 2020 relative to summer.

4 Other mitigating measures


This section explores some of the additional measures available to mitigate risk of airborne transmission
of COVID-19 in indoor environments. Here by ‘airborne’ transmission we mean transmission via smaller
particles which can be suspended in the air for a considerable time. By ‘droplet’ transmission we mean
short-range transmission via larger droplets which fall to a surface within seconds and within a few
meters of the infected person.
The risk of airborne transmission indoors can be mitigated through dilution of the indoor air by clean
outdoor air, as discussed in §3. This requires a ventilation system for which the air intake can be
increased, or installing secondary ventilation systems. Substantially increasing the ventilation in a space
is often impractical. Further, in order to reduce the risk of infection by a factor, the ventilation rate
must be increased by the equivalent factor. Increasing the volume of outdoor air becomes particularly
challenging in winter without compromising the thermal comfort of occupants or energy use (due to an
increased heating load). These factors limit the viability of reducing risk by increasing ventilation.
The mechanisms for the transmission of COVID-19 are not yet well understood. Reducing the risk of
infection to zero is not possible (short of global eradication), therefore, where practical to do so, all
available measures should be taken in order to gain the biggest reduction in risk. In the absence of or

18
to complement increased ventilation, alternative engineering control measures can be used. Some of the
measures available are discussed here.

4.1 Air filters or cleaners

Filters and air cleaners, such as UV cleaners or photocatalytic oxidation, can either be installed di-
rectly within the existing ventilation system, removing virus-laden particles from recirculated air, or as
independent units within a room to supplement the existing ventilation.
In their latest guidance document in response to the pandemic, The Federation of European Heating,
Ventilation and Air Conditioning associations (REHVA) recommend avoiding the use of centralised
recirculation as typical local air filters within these systems are not effective at filtering out viral material
which tends to be too small for the filter (REHVA, 2020). Installing high-efficiency particulate air (HEPA)
filters would allow virus-laden particles to be removed, however these are not easily installed in existing
systems and further system modifications are required in order to provide a higher pressure drop to
maintain the same airflow rate.
Standalone air filters can be effective at removing virus-laden particles provided they target the appro-
priate range of particle size. However, regardless of the efficacy of the filter itself, the supply of clean
air is limited by the flow rate of air passing through the filter. Despite this, the supply of clean air in
a space can be up to 1000 m3 /hr (Zuraimi et al., 2011). However, filters require regular servicing to
maintain their effectiveness - clogged filters lead to a build up of viral particles and can act as a source
of viral matter rather than a sink (Eames et al., 2009).
Air cleaners such as UV air cleaners are also limited by the volume of air that can be passed through
the device. UV light has been shown to be effective in deactivating various viruses under laboratory
conditions, including coronaviruses (Morawska et al., 2020; Beggs & Avital, 2020). While the evidence
that UV is effective against SARS-CoV-2 specifically is currently limited, it seems highly likely to be the
case (Beggs & Avital, 2020).
The efficacy of air filters and cleaners is likely to be highly sensitive to their location within a room.
Depending on the size, shape and airflow patterns within a room, the air within some areas of the
room may never reach the device. In the worst case scenario, the device simply recirculates the same
small volume of air within a much larger room. Therefore while these devices tend to promise certain
air changes per hour (AC/hr) equivalent of clean air, in reality this is only true if the air pulled in by
the device has not already been cleaned. In smaller, poorly ventilated rooms such devices are likely to
provide significant benefit, however for larger spaces an understanding of the airflow patterns within the
room is required to ensure that the device is effective.
Care should be taken when considering which air cleaner/filter to use as many devices have been found
to have a limited effect (Siegel, 2016; Zuraimi et al., 2011). HEPA filters are often recommended as the
most effective technology currently available (e.g. Zuraimi et al., 2011).

4.2 Personalised ventilation

Personalised ventilation (PV) supplies clean air directly to the breathing zone of an occupant of a room
via a device installed at their workstation. A certain minimum velocity is required for the supplied air
in order to penetrate the convective flow driven by body heat (Melikov, 2004). Further, a large target
area is desired in order to account for occupants’ movement. The required rate of clean air supply can
therefore be high. While studies have shown that PV can be effective at reducing risk for occupants
while at their workstations (Melikov et al., 2002; Melikov, 2004), protection is not provided to occupants
when away from their workstations. PV may in fact facilitate the transport of exhaled pathogens to
other occupants (Bolashikov & Melikov, 2009). Installing a personalised device for all occupants in an
office is also likely to be expensive and impractical.
PV may be most viable in scenarios where the occupant is required to remain at their workstation for
the duration of their shift.

19
4.3 Desk and ceiling fans

While desk or ceiling fans do not enhance the bulk supply of outdoor air, they can be used to increase
air mixing within a room, which may lead to a more homogeneous distribution of virus-laden particles.
Where areas of stagnant air are identified (or are suspected), a fan can be used to increase mixing with
the wider space, therefore potentially reducing the risk of the accumulation of virus-laden particles within
the stagnant zone.
The localised (relatively) high velocity air flows produced by desk fans may result in increased re-
suspension of virus-laden particles and this risk should be considered. However, studies have found
that using either desk or ceiling fans to increase air mixing within a room can lead to increased rates of
deposition (Mosley et al., 2001; Thatcher et al., 2002; Xu et al., 1994). These experiments use oil droplets
(Thatcher et al., 2002), cigarette smoke particles (Xu et al., 1994) and a combination of oil droplets,
salt and incense (Mosley et al., 2001) under controlled laboratory conditions. However, deposition rates
can vary by orders of magnitude depending on the particle size, room surface-to-volume ratio (which
was varied predominantly via the inclusion of furniture) and airflow speeds and turbulence within the
space. Generally the removal of airborne particles through deposition is likely to be much lower than that
through ventilation, however for poorly ventilated rooms these rates can be comparable, particularly for
larger particles (> 1µm). It is unclear whether the results of these studies would translate to increased
deposition rates of COVID-19-laden particles under real-world conditions. The impact of changing
deposition rates on the risk of surface transmission via fomites is also unclear.
Due to this uncertainty and the potential risk of increasing the re-suspension of virus-laden particles
within the space, the use of desk fans is generally not recommended. However, when a stagnant zone is
evident, either via intuition (e.g. sheltered spaces like reading corners within classrooms and breakout
spaces within open-plan offices) or through monitoring CO2 concentrations, the benefit of using a desk
fan to increase mixing with the wider space may outweigh the potential drawbacks. Where fans are used
in this capacity they should be orientated such that increased mixing is achieved between the stagnant
zone and the surrounding space (into which the outdoor air provision should be checked).
Ceiling fans promote vertical mixing of air within rooms and, in addition to increased bulk mixing, help
reduce temperature stratifications from forming within the room. As such where the ventilation strategy
relies on stratification within the room, e.g. where a displacement ventilation strategy can be successfully
evidenced, the use of ceiling fans is not recommended. Otherwise, temperature stratification within a
room could significantly inhibit the vertical mixing, and dilution, of virus-laden particles from within the
breathing zone. Moreover, in the heating season the downwards mixing of warmer air from the ceiling
can enable the increased supply of outdoor air without compromising thermal comfort (nor increasing
the energy consumption associated with heating). Further, their use in conjunction with upper room UV
(see §4.6) has been found to greatly increase the exposure of virus-laden particles to the upper region of
the room (McDevitt et al., 2008; Morawska et al., 2020).

4.4 Air ionisation

Air ionisation is a relatively new technology and involves the production of ions such as the hydroxyl
radical (OH − ) from a corona discharge between two high potential electrodes. These ions have been
shown to have germicidal properties as they react with the surface structure of the pathogen (Bolashikov
& Melikov, 2009). The technology was shown to be effective against certain bacterial pathogens when
installed in a hospital intensive care unit, but with no effect on others (Kerr et al., 2005). Ionisers are
easy to deploy and have high energy efficiency but have not been evidenced as effective devices against
viruses including SARS-CoV-2. Some devices are known to produce ozone so their effect on air quality
should also be considered (Siegel, 2016). However, PV has mainly been researched in idealised laboratory
settings and its potential for mitigating airborne infection is not yet understood.

4.5 The use of screens

Using screens to provide a physical barrier between the occupants of a space is a simple and easily
applied measure to mitigate the risk of transmission. The use of screens is widespread in hospitals and

20
the commercial sector; in supermarkets they are used to provide a barrier between the shop assistant
and the customer.
However, this application is targeted at reducing the risk of infection via larger droplets. There are
very few examples of the use of screens to mitigate airborne transmission (i.e. smaller droplets or
droplet nuclei), either by providing a barrier directly between occupants, or in an attempt to favourably
manipulate the airflow patterns within a space. Noakes et al. (2006) use CFD simulations to investigate
the effect of partitioning a hospital ward room on the risk of patient-to-patient and patient-to-visitor
transmission. They conclude that, combined with carefully considered changes to the positioning and
number of the ventilation inlets and outlets, the risk of infection can be reduced significantly. However,
in some instances the risk of transmission from patient to visitor was increased by the presence of the
partition due to reduced airflow in certain areas of the room.
This highlights the main problem with the use of screens indoors; the impact of the screen on the airflow
patterns within a space is very difficult to predict. While the exchange of air between two areas of a
room may be reduced, the presence of a screen can lead to areas of stagnant or recirculating flow where
the virus could accumulate. Further to this, installing screens which affect airflow would require an
evaluation of the impact on any environmental monitoring undertaken, and crucially on fire safety (e.g.
as they may prevent smoke from reaching the smoke detector or have other fire safety implications).

4.6 Upper room Ultra-Violet Germicidal Irradiation

Upper room UV provides a way to utilise the deactivating properties of UV light without the limitation
of the airflow rate through a cleaning unit. While real world studies of its application are limited (e.g.
McLean, 1961), laboratory and modelling studies suggest that, provided sufficient efficacy of UV in
deactivating the virus, the method can be effective at mitigating airborne transmission (e.g. Escombe
et al., 2009; Noakes et al., 2015). Upper room UV is likely to be at its most effective in poorly ventilated
spaces (Noakes et al., 2015) and can be installed reasonably easily at a low cost. However sizing a system
is not always straightforward, and it is essential that systems are installed by professionals who also
ensure that occupied zone UV-C irradiation levels are safe.
The method depends on the virus reaching the upper section of the room which is exposed to UV light.
Therefore, appropriate internal flow patterns are required in order to ensure that the virus is transported
through the unit and deactivated. The process is complicated by the large range in particle sizes (see
§2.1.1) produced by an infected person, where larger particles require higher vertical velocities to be
carried to the upper section. Therefore, while a large range of particle sizes may well be deactivated,
there is a danger that a certain fraction remains. Studies such as Nardell et al. (2008) have demonstrated
that the method can be implemented with minimal risk to occupants due to UV exposure. Further,
“ozone-free” UV lamps can be used to avoid adverse effects on indoor air quality due to the production
of ozone. Only real world trials will prove the efficacy of the method (see §C) and costs (of purchase,
installation and maintenance) should always be compared to the equivalent costs of appropriate upgrades
to the ventilation provision to the indoor space.

4.7 Summary

Each of the engineering control measures considered here have their advantages and limitations, and
none are able to entirely eradicate the risk of transmission. Upper room UV holds promise as a method
to significantly reduce the risk of transmission, particularly in poorly ventilated spaces. However further
effort is required to demonstrate its effectiveness against SARS-CoV-2 in real world scenarios. Air
ionisation is an emerging technology, but there are unresolved concerns regarding its impact on indoor
air quality, primarily due to the production of ozone, and there is little evidence that it is effective
against viruses. The addition of air filters that are effective against viral transmission to the existing
ventilation system are likely to require complementary modifications to the ventilation system to, at the
very least, account for the changes in pressure drops across the system. Independent filter units can be
used, however in order to maximise their impact in larger spaces an understanding of the airflow patterns
within the space is useful. Filters are an established technology which are likely to reduce risk without
any detrimental impact to occupants if appropriate maintenance can be ascertained and achieved. Using
desk fans to increase the mixing of air within a room is easily applied and may be a very affordable

21
measure, however their merits are questionable in the absence of evidence of stagnant zones. Ceiling
fans provide the benefit of increased vertical mixing within the room. However in the case of both desk
and ceiling fans there are uncertainties as to their impact on re-suspension and deposition of virus-laden
particles and the associated impact on transmission risk. The use of screens can be effective to mitigate
spread via the droplet route, but their use is problematic as a measure against airborne transmission since
impacts on the circulation of air and the local ventilation provision is unpredictable without detailed
bespoke study. Moreover, a full assessment of a screen’s impact on fire safety would be required ahead
of any installation.
The primary control measure for airborne transmission indoors is ventilation and achieving adequate
outdoor air supply rates to ensure an acceptable level of risk should be the priority. However, where
additional risk reduction is required or desired other measures can be implemented to help mitigate
the spread of COVID-19. Where the intention of these measures is to reduce the risk of airborne
transmission their costs should always be compared to the cost of upgrading the existing ventilation
provision. Moreover, these measures should always be implemented in addition to any existing measures
to reduce the spread of infection via all routes of transmission, e.g. adequate hand hygiene & cleaning,
the wearing of face coverings or other personal protection equipment (PPE) and social distancing.

5 Author contributions
This document results from the work and discussions led by Professors Paul Linden (pfl4@cam.ac.uk)
and Christopher Pain (c.pain@imperial.ac.uk) under Task 7 (Environmental and aerosols transmission)
within the Royal Society’s ‘Rapid Modelling of the Pandemic project’ (RAMP).
Dr Henry Burridge (h.burridge@imperial.ac.uk) led the compilation and editing of this document. Drs
Megan Davies Wykes, Hywel Davies & Shaun Fitzgerald, and Professor Paul Linden each acted in the
capacity of supporting editors; all members of RAMP Task 7 contributed directly or indirectly to the
production and editing of this body of work. Further notable contributions include:
Production of executive summary:
• Henry Burridge (h.burridge@imperial.ac.uk)
Production of text concerning COVID-19 transmission indoors and transmission via droplets and aerosols:
• Rajesh K. Bhagat (rkb29@cam.ac.uk)
• Marc Stettler (m.stettler@imperial.ac.uk)
• Prashant Kumar (p.kumar@surrey.ac.uk)
Production of text concerning transmission via surface contacts & fomites, and the appendix ‘SARS-
CoV-2 on hard surfaces’:
• Ishanki De Mel (i.demel@surrey.ac.uk)
• Panagiotis Demis (p.demis@surrey.ac.uk)
• Allen Hart (ah792@bath.ac.uk)
• Yyanis Johnson-Llambias (yjl31@bath.ac.uk)
• Marco-Felipe King (M.F.King@leeds.ac.uk)
• Oleksiy Klymenko (o.klymenko@surrey.ac.uk)
• Alison McMillan (a.mcmillan@glyndwr.ac.uk)
• Piotr Morawiecki (pwm27@bath.ac.uk)
• Thomas Pennington (tp373@bath.ac.uk)
• Michael Short (m.short@surrey.ac.uk)
• David Sykes (david67sykes@gmail.com)
• Philippe Trinh (p.trinh@bath.ac.uk)

22
• Stephen Wilson (s.k.wilson@strath.ac.uk)
• Clint Wong (clint.wong@maths.ox.ac.uk)
• Hayley Wragg (hw454@bath.ac.uk)
Production of text concerning social distancing indoors:
• Megan Davies Wykes (msd38@cam.ac.uk)
Production of text concerning guidance on face masks and coverings, and the appendix ‘Summary of
current recommendations for the use of face masks or coverings’:
• David Sykes (david67sykes@gmail.com)
• Chris Iddon (naturalventilation@cibse.org)
Production of text concerning source reduction through timetabling, and the purging between events:
• Henry Burridge (h.burridge@imperial.ac.uk)
Production of text occupancy behaviour on indoor air movement:
• Andy Woods (aww1@cam.ac.uk)
• Nicola Mingotti (nm441@cam.ac.uk)
• Neeraja Bhamidipati (nb522@cam.ac.uk)
Production of text concerning ventilation and the airborne transmission route:
• Henry Burridge (h.burridge@imperial.ac.uk)
Production of text concerning local air movement and purification:
• Huw Woodward (huw.woodward@imperial.ac.uk)
Production of text concerning upper room Ultra-Violet Germicidal Irradiation:
• Huw Woodward (huw.woodward@imperial.ac.uk)
Production of the appendix ‘Natural inputs to ventilation provision’:
• Chris Iddon (naturalventilation@cibse.org)
Production of the appendix ‘UVGI and COVID-19’:
• Clive Beggs (C.Beggs@leedsbeckett.ac.uk)
Production of the appendix ‘Aerosols in the context of singing, and woodwind & brass musical instru-
ments’:
• Alison McMillan (a.mcmillan@glyndwr.ac.uk)

A Natural inputs to ventilation provision


By design well-sealed buildings have ventilation provision that has been specified and installed, as per our
guidance (§1 and §3.2) we recommend this provision is reviewed in light of COVID-19 prior to winter 2020.
Many more buildings are, by design or otherwise, not well-sealed and in such cases the increased supply
of outdoor air by natural means (e.g. through opening windows, doors, vents, louvres, etc. . . ) may offer
potential to mitigate risk of airborne transmission. However, these naturally driven flows rely on driving
winds (which in winter are typically colder than comfortable indoor temperatures) or buoyancy (arising
from temperature differences between indoor and outdoor aid) and so if not managed carefully will
lead to either significant increases in heating bills and/or zones where cold draughts are uncomfortable.
In this appendix, we seek to discuss practical means by which these natural flows can be exploited to
mitigate risk but in a manner which attempts to balance the potentially negative consequences for indoor
experience and energy consumption.

23
A.1 Natural Ventilation in winter

The amount of outdoor air that can be reasonably provided during winter may be less than in the summer
due to impacts on indoor air temperature and occupant comfort. As there is a high confidence that,
compared to adequately ventilated spaces, poorly ventilated spaces increase the risk of SARS-CoV-2
transmission via the far field (>2m) airborne route, it is important to ensure that poorly ventilated
spaces are avoided.
Approved Document Part F (ADF) sets out what, in ordinary circumstances, may be accepted as reason-
able provision for compliance to the Building regulations: There shall be adequate means of ventilation
provided for people in a building (Government, 2013). At the least, it is important to ensure that adequate
ventilation is provided year round (poor indoor air quality also negatively impacts health, wellbeing and
productivity Kukadia & Upton, 2019). Wherever possible outdoor air flow rates should be maximised
(i.e. increased more than the ADF provision rates for adequate airflow) where it is reasonable to do so.
For low occupancy indoor spaces it may be that an airflow rate measured in litres per second per person
(l/s/p) only provides a low overall flow rate and in these cases a minimum flow rate should be considered
(Jones et al., Pre-print).
However increased ventilation in the winter may lead to unwanted occupant behavioural responses that
result in ventilation provision being deactivated or minimised. For example, increased ventilation could
result in colder indoor environments or cold draughts resulting in occupants closing or turning off ven-
tilation provision. Thus, the goal of increasing ventilation provision results in no, or little, ventilation
provision if such behavioural responses are elicited. Ventilation plays a key role in dilution of airborne
SARS-CoV-2 encapsulated in respiratory aerosol — poorly ventilated spaces increase the risk, although
there is a diminishing law of returns in increasing the ventilation rate. The potential benefits of increas-
ing ventilation to a poorly ventilated space are greater than increasing a well-ventilated space by the
same amount (Jones et al., Pre-print).
In winter, the driving forces for natural ventilation are usually greater (pressure differences caused by
wind and indoor/outdoor temperature differences CIBSE, 2015, 2005) and therefore, to deliver the same
flow rate, openings do not need to be as wide in the winter as they would need to be in the summer.
What follows provides guidance for modulating various ventilation openings to deliver outdoor airflows
whilst minimising occupant discomfort.

A.1.1 Adjusting airflow through natural ventilation openings

A single set of high- and low-level openings: In this configuration it is preferable to open the high level
vents first to provide outdoor air, and to open the low level windows to further maximise airflow when
reasonable. The turbulent plume of cooler outdoor air entering through high level vents will entrain
warm room air as it falls under gravity, tempering the air before it enters the occupied zone (Turner,
1973). A helpful draught plume calculator is available in the BB101 calculation tools, which enables this
effect to be measured (DepartmentforEducation, 2018b). A safe means of opening and closing high level
vents should be supplied in workplaces (Government, 1992b, , regulation 15).
Multiple openable windows and/or vents: Where a room has multiple openable vents, it may be possible
to deliver the adequate ventilation provision through opening of just one vent. However, it is usually
possible to create a more comfortable indoor environment, with respect to draughts, if the airflow is
achieved through opening all the vents by a smaller amount than that necessary in the scenario of a
single set of openings as described above. If there are openable vents at both high and low level, then
the principle of opening as many high level vents should initially be considered (see above).
Sash windows: As with high and low level windows, it is better to open the high level sash to provide
openings at the top of the vent to encourage entrainment of outdoor air with the warm indoor air in the
first instance. To further increase outdoor airflow the bottom sash can also be opened.
Other vents: In addition to windows, there are other vents and louvre systems that can be modulated
and similar to windows, the principles of opening high level vents and multiple vents a small amount
should be considered in the first instance.
CO2 sensors: High levels of CO2 (i.e. values greater than 1 500 ppm) are indicative of a poorly ventilated
space, and therefore CO2 can be a useful indicator of a space that is lacking adequate ventilation.

24
However, low CO2 concentrations are not necessarily indicative of a well ventilated space. If CO2
sensors are to be deployed they should be Non-dispersive Infra-red (NDIR) CO2 sensors, which actually
detect CO2 in the space, rather than the less expensive eCO2 sensors that do not detect CO2 and infer
a CO2 concentration by measuring room volatile organic compound (VOC) concentrations instead.

A.1.2 Occupant Comfort

A person’s sensation of warmth is influenced by the following main physical parameters, which constitute
the thermal environment:
• air temperature,
• mean radiant temperature,
• relative air speed, and
• humidity.
Besides these environmental factors there are personal factors that affect thermal comfort:
• metabolic heat production, and
• clothing.
It is possible to adjust the personal environmental factors to improve occupant comfort, particularly
where outdoor air supply may decrease occupant comfort. CIBSE Guide A describes the predictive mean
vote (PMV) method of measuring occupant thermal comfort, which can be used to see how changes to
apparel and metabolic activity can improve occupant thermal comfort (CIBSE, 2015).
Clothing: Clothing provides a layer of insulation that contributes to the occupant’s perception of comfort
and is dependent upon the material and fit. Typically winter wear would have a value of 0.8 to 1.0 clo,
although studies in recent decades in Europe and the UK have found values generally at the lower end.
This may be a result of occupants acclimatising to, and expecting, warmer indoor environments in the
winter. For example compare typical winter office clothing of the 21st Century, with that in vogue at
the turn of the 20th Century. To improve occupant comfort, particularly in naturally ventilated indoor
spaces, occupants should be encouraged to dress appropriately and relaxation of dress codes should be
considered if necessary to allow warmer clothes to be worn.
Metabolic rate: Sedentary activities have a relatively low metabolic activity which can contribute to
occupant thermal discomfort. Encouraging periods of activity, to move around the room, or partake
in some light exercise, will help to improve thermal comfort – as well as aiding in meeting display
screen equipment (DSE) regulations which require regular breaks or changes in activity when using DSE
(Government, 1992a) and recommendations for regular movement to improve health.
Position of occupants in relation to openable vents: Where it is possible, increasing the distance of
occupants from openable vents provides more time for incoming cool air plumes to entrain with warm
room air prior to entering the occupied zone.

A.2 Summary

We summarise by first suggesting that when attempting to reduce the risk of airborne spread of COVID-
19 by increasing ventilation through natural means (e.g. opening windows wider) occupants comfort
be given due consideration; otherwise, the chances that occupants act to intervene and unintentionally
increase infection risk (e.g. by closing windows) is significant. To that end, the principles that high-level
ventilation openings should be preferentially used, and that multiple smaller openings are preferable to
a lesser number of larger openings, should be employed. Given that the maximum capacity of heating
systems are broadly fixed and should be designed to accommodate the ventilation air required to deliver
adequate indoor air quality, we do not encourage large increases in energy consumption, to ventilate an
indoor space, beyond that which is absolutely necessary.

25
B SARS-CoV-2 on hard surfaces
Respiratory viruses can be transmitted from an infected individual to a susceptible host through three
main pathways illustrated in Figure 4. In this report, we focus on pathogen transmission mediated
by surfaces of inanimate objects known as fomites that, when contaminated with an infectious agent,
can transfer disease to a new host. Fomite contamination can occur through: (i) direct contact with
infected individuals and their bodily secretions/fluids; (ii) bioaerosols generated via breathing, talking,
sneezing, or coughing; (iii) by an airborne virus that settles after a contaminated fomite is disturbed. A
susceptible individual coming into contact with a contaminated fomite surface may pick up the pathogen
and self-inoculate leading to infection.

Figure 4: Three potential transmission pathways for respiratory viruses. [obtained from Zhang et al.
(2018)]

Risk of viral infection through fomites can be assessed on the basis of three main considerations which
determine the quantity of pathogen picked up upon touching the surface:
1. The concentration of virus on the surface, which is affected by
(a) source of virus (e.g. sneezing, coughing or touching the surface by infected individuals)
(b) time elapsed since surface contamination
(c) surface characteristics (e.g. material, smoothness, roughness, porosity) which affect the sur-
vival of the virus
(d) environmental and skin conditions (e.g. temperature, humidity, perspiration)
(e) cleaning and/or disinfection activities since contamination
2. The probability/frequency of contact with a contaminated fomite (e.g. through touch by hand);
probability of virus transfer from hands to the mucous membranes of mouth or nose
3. The individual susceptibility to the virus (dose response curve)
Many of the above factors are hard to quantify or control, and hence there is limited existing knowledge
on transmission via fomites. In most settings the exact pathway of respiratory virus transmission is not
known because of continuous interplay between the surface and droplet/airborne transmission pathways
through droplet deposition and possible re-suspension of the pathogen. Although most of the evidence
of fomite transmission is indirect, and no evidence has yet been reported for SARS-CoV-2, it is generally
accepted that viruses can survive on hard surfaces for prolonged periods of time, that they can be
transferred between fomites and hands, and that hands come into contact with mucous membranes, thus
enabling this transmission pathway (Boone & Gerba, 2007; Kutter et al., 2018).
The report will not cover aspects related to aerosol deposition of the virus (including the effects of
ventilation on the rate thereof) which, although crucial for the quantification of risk of infection, is not
within the remit of Subgroup 4. The topic of virus re-suspension will also not be covered due to lack of
evidence in the literature.

26
B.1 Surface deposition and contact frequency

The risk of infection through fomites depends on the frequency of contact with contaminated objects.
It is therefore important to have quantitative information about the level of contamination of different
surfaces as well as the likelihood of susceptible individuals coming into contact with them. Figure 5,
from Chia et al. (2020) shows that SARS-CoV-2 is easily transported and deposited onto surfaces in a
hospital setting (airborne infection isolation rooms), with certain surfaces that are commonly handled
showing traces of the virus. Note that the figure indicates the likelihood of finding the virus on different
surfaces but does not reflect actual viral loads found on them.

Figure 5: Percentage of contaminated swabs from surface samples in a hospital room housing a SARS-
CoV-2 patient. [obtained from Chia et al. (2020)]

Zhang et al. (2018) have reported a large study of surface touch in a student office, in which they collected
over 120,000 touch events. They introduce a classification of surfaces into high-touch (e.g. those touched
multiple times by the same person) and high-risk surfaces (touched by multiple individuals) as well as
private (e.g., a mobile phone) and public (e.g., door knob, light switch, etc.). The study revealed that
96.7% of touches in an office setting involved private surfaces and only 1.2% of the touches were of
public surfaces which play the most important role in fomite transmission. The authors use a network
approach to assess ‘distances’ between surfaces in the surface touch network and the dynamics of spread
throughout the office. The paper also reports frequencies and average durations of contact with various
surfaces in a student office which provides rich data for modelling transmission.

B.2 Factors affecting survival of virus on surfaces

The survival of viruses on surfaces is strongly impacted by the type of surface and surface material upon
which it is deposited as well as by a number of environmental factors such as ambient temperature, light,
humidity, and pH (if in droplet form on surface). Additionally, factors such as type of contamination
(fingertip, droplet, etc.) and the concentration of the virus inocula (relevant to droplets) are important
(Warnes et al., 2015). For SARS-CoV-2, the virus was found to be active across a wide range of pH,
from 3 to 10 (Chin et al., 2020) and so changing the pH to deactivate the virus may not be a feasible
option.

B.2.1 Surface material

The type of surface can affect the stability of the SARS-CoV-2 virus. A study has investigated the
stability of both SARS-CoV-1 and SARS-CoV-2 viruses on plastic, stainless steel, copper and cardboard
surfaces under conditions of 21–23◦ C and 40% relative humidity (van Doremalen et al., 2020). Note that

27
Figure 6: Exponential decay and half-lives of SARS-CoV-2 virus (red) and SARS-CoV-1 virus (blue) on
different surfaces. [obtained from van Doremalen et al. (2020)]

the initial concentration of the virus used on the surface is 103.7 TCID50 per ml of medium. The virus
decayed exponentially with time on each of these surfaces, as seen in Figure 1. The half-lives of the virus
on plastic and stainless steel have been reported as 6.8 hours and 4.6 hours, respectively. From Figure 6,
the half-lives of the virus on cardboard and copper are approximately 4 hours and 1 hour, respectively.
This study also reports that the amount of infectious virus greatly reduced within 72 hours and 48 hours
for plastic and stainless steel, respectively, and that no infectious virus was found on cardboard and
copper after 24 hours and 4 hours, respectively.

Table 2: Time taken (approximate) for no infectious virus to be found on each surface (Chin et al., 2020).

Surface Time taken (hours)


Stainless Steel 168
Plastic 168
Wood 48
Cloth 48
Paper 3
Tissue 3
Glass 96
Bank note 96
Mask (inner layer) 168
Mask (outer layer) >168

The stability of the SARS-CoV-2 virus on stainless steel, plastic, wood, cloth, paper, tissue, banknote
and inner and outer layers of a surgical mask has been evaluated by Chin et al. (2020). Each surface
was pipetted with a virus culture of approximately 107.8 TCID50 per ml of medium (higher than the
concentration used in van Doremalen et al. (2020)), maintaining conditions of 22 ◦ C and 65% relative
humidity. This study has not reported the half-lives of the virus on each of these surfaces; however, the
authors have reported the time it took for no infectious virus to be detected on each surface. Table 1
summarises their findings.
Results also show that both inner and outer layers of the mask retain infectious virus for a significantly
long time (Chin et al., 2020). However, it is possible that their experimental approach does not truly
reflect a real scenario, as the virus culture has simply been pipetted onto the inner layer of the mask. It

28
is not clear from this study whether it is possible for the virus medium (especially in droplet form) to
seep through from the outer layer to the inner layer and retain a high concentration of the virus within
the inner layer. Furthermore, it is unlikely that the inner layer of the mask would remain at 22 ◦ C in
reality, as exhaled air from the nose would increase the temperature.
The study also concludes that the virus remains stable for longer on smooth surfaces (Chin et al., 2020);
however, note that roughness/smoothness has not been quantified. Exceptions to this have been seen
in a study performed on the Coronavirus 229E strain (Warnes et al., 2015). The authors of this paper
report that an increase in the copper content of a surface (such as in brass) can significantly reduce
the time taken for the virus to be inactivated. They claim that this inactivation is due to the release
of copper ions and reactive oxygen species. It is possible that this phenomenon is the cause of the low
half-life reported for SARS-CoV-2 on copper, as seen in van Doremalen et al. (2020).
Biryukov et al. (2020) has studied the half-life of SARS-CoV-2 on stainless steel, plastic, and nitrile gloves
(all nonporous surfaces) under various temperatures and relative humidities (see section on Effects of
Temperature and Humidity). Interestingly, their results do not show significant variations in viral decay
rates on these surfaces when environmental conditions are kept the same, and conclude that surface type
does not impact viral stability. It is unknown why these results are different from those of van Doremalen
et al. (2020) and Chin et al. (2020), highlighting the need for further experiments in this area.

B.2.2 Effects of temperature and humidity

Experiments on SARS-CoV-2 under varying temperature have showed that the virus is less stable under
increasing temperature (Chin et al., 2020; Dietz et al., 2020). Chin et al. (2020) show that the inactivation
of the virus can be reduced to 5 minutes at a temperature of 70 ◦ C, whilst remaining stable for over 14
days at 4◦ C.
Biryukov et al. (2020) have analysed the effects of different temperatures (24◦ C and 35◦ C) and relative
humidities (20%, 40%, and 60%) on SARS-CoV-2, diluted in saliva and deposited on surfaces in droplet
form. They confirm that the half-life of the virus is reduced when temperature and humidity are increased,
either independently or in combination (the lowest half-life of approximately 2 hours has been reported
for the temperature-humidity combination of 35◦ C and 60%). While they also analyse the effects of
different droplet sizes and deposition on three different nonporous surfaces (stainless steel, plastic and a
nitrile glove), they conclude that the size of the droplet and surface type do not significantly impact the
half-life.
Studies on other strains of coronaviruses show similar trends (Kampf et al., 2020; Ren et al., 2020). One
study reports that temperatures of 30 – 40◦ C is sufficient to reduce time taken to inactivate viruses
(Kampf et al., 2020). Casanova et al. (2010) also concludes that increasing both temperature and
humidity have contributed to faster inactivation/decay of coronaviruses. A review on viruses on surfaces
has reported that the viruses are more stable at relative humidity levels below 50% (Vasickova et al.,
2010). Dietz et al. (2020) predicts that higher relative humidity facilitates larger droplets containing
viruses to settle on surfaces more quickly, thus reducing airborne transmission (Dietz et al., 2020).
Based on these results, we can conclude with a high level of certainty that virus stability on surfaces de-
creases with increasing temperature and humidity. In reality, relative humidity levels should be increased
cautiously as levels of 80 % or greater can lead to mould growth (Dietz et al., 2020).

B.2.3 Effects of surface finish, texture or roughness

All surfaces are inherently rough at some length-scale, and the particular quality of the surface is de-
termined by the method of manufacture and any finishing processes, such as polishing. Even with the
most sophisticated finishing processes, it has to be accepted that some roughness remains, and that the
length-scale of the roughness features might be of a similar size to that of some droplets falling onto that
surface. This then prompts questions as to differences in evaporation, adhesion, surface tension, and
touch transferability of viral material contained in droplets that land proud on a smooth (or relatively
smooth) surface, to those that land or flow down into roughness grooves in the surface.
The science of surface characterisation, rubbing friction and surface lubrication is called “Tribology”,
and was established by Bowden & Tabor (1950). Surface texture (deliberate or arising from roughness) is

29
Figure 7: Illustration of how a droplet in a surface roughness groove (left) can be inaccessible to finger
touch compared with a droplet on a smooth surface (right).

characterised in a number of ways, but a common metric is Ra , which is defined as the arithmetical mean
deviation of the surface profile being assessed. Other metrics consider peak to trough distance, root-
mean-square, statistical aspects (skew and kutosis), or reflect more directly the method of measurement
(sizes and numbers of peaks and troughs over a given measurement area). Another approach recognises
a fractal-like distribution in roughness and characterises roughness based on Box-Fractal dimension
(Mandelbrot et al., 1984; Mandelbrot, 2006). For the present purposes, a suitable characterisation
should express the fraction of surface area which would be likely to catch droplets of a given size within
a trough-like region. On the basis of simple geometric considerations, one could imagine that for some
combination of surface roughness types and droplet size and number, the contamination would mainly
fall beneath the level at which a finger could press into the surface to touch, as illustrated in Figure 7.
Another aspect that would influence the survival of infected droplets on surfaces is the adhesion of the
droplet to the surface. The authoritative text on the subject of adhesion and adhesives is that by Kinloch
(1987). The geometric interlocking of interfaces is not thought to be a strong factor in surface adhesion,
but in considering the removal of droplets or dried droplet residue from a surface, there is a question
to be asked of whether such material can be wiped off cleanly, or whether some material is forced more
deeply into grooves on the surface. Understanding adhesion mechanisms at the micro-scale could provide
some valuable insight into the mechanical aspects of the cleaning process.

B.3 Modeling approaches

B.3.1 A model to predict viral transfer from surfaces

Transfer of microorganisms to hands from contaminated surfaces can be modelled mechanistically King
et al. (2020):

CH = λS→H CS (1)

where CH is the concentration of virus on fingers, λS→H is the percentage transfer during a single
contact which is pathogen and surface dependent and CS is the concentration on the surface. This can
be extended to multiple contacts:

Cn = Cn−1 + λS→H (CS − Cn−1 ) (2)

where n is the nth surface contact. λS→H is difficult to measure accurately and while experiments are
underway to quantify this for SARS-CoV-2, surrogates can be used. Kraay et al. (2018) suggest λS→H
for influenza may lie between 4% and 16%, whilst rhinovirus may range up to 40%. Data of finger
to mucosa transfer is much more scarce but Rusin et al. (2002) estimates a viral surrogate at 33.9%
(unpublished standard deviation was later found to be 16%).

30
B.3.2 A model to predict viral decay rate

A simple thermodynamic model has been developed by Yap et al. (2020) which reasonably predicts the
decay rate of different coronaviruses including SARS-CoV-2 at different temperatures. By assuming an
exponential decay for the quantity of pathogens, C, with
C = C0 e−kt ,
where C0 is the initial quantity, t is time (seconds) and k is the decay rate. The decay rate is assumed
to satisfy a relation (the Arrhenius equation) that is typical for the thermal denaturation of protein,
namely
k = Ae−Ea /RT ,
where T is the ambient temperature (Kelvin), R is the Gas constant, Ea is the activation energy (J/mol)
and A is an arbitrary frequency in the limit of high temperature. In particular, they found a universal
relation (a Meyer-Neldel relation) between Ea and A for different coronaviruses, namely
log(A) = 0.394Ea − 5.63,
based on experimental data from previous work. Although it has been assumed that this relation holds
for all temperatures, the authors claimed that this is a reasonable assumption for proteins and, most
importantly, this relation also has good agreement with previous findings. For SARS-CoV-2, we can
readily predict the decay rate using the experimentally fitted value Ea = 135, 692 J/mol.
The authors have also suggested that this model can be extended to incorporate other catalytic effects
e.g. humidity and surface properties by establishing further relations with the activation energy.

B.3.3 Droplet evaporation from a surface

Numerous studies exist for the size of saliva droplet upon expulsion from the mouth (via breathing
and coughing), with results between studies showing considerable variance. However, by assuming the
mechanical properties of pure water, the mathematics is well-established for predicting the time scale for
such droplets to evaporate, namely
ρθ
tevap ∼ R2 ,
D(1 − H)csat 0
where ρ is the density of water, θ is the contact angle, D is the diffusion coefficient, H is the relative
humidity, csat is the saturation concentration of vapour in air and R0 is the initial droplet radius [see
Dunn et al. (2009) and Bhardwaj & Agrawal (2020) for further details on how these parameters depend
on temperature and humidity].
There is evidence of a slower drying time of saliva as compared to pure water; In Liu et al. (2017), saliva
droplets released onto a Teflon-printed slide showed a 20% longer evaporation time than those consisting
of pure water. These results were especially pronounced at lower humidities and over longer time periods.
Additionally, the same study notes evidence that droplets produced by coughing may be more likely to
contain a higher solute concentration, due to the presence of pulmonary mucus. Droplets produced by
coughing are also larger in size (Chao et al., 2009), indicating a greater likelihood to be deposited on
surfaces.
Under the assumption of pure water properties, such physical modeling indicates total droplet evapora-
tion within seconds, which is multiple orders of magnitude less than the typical lifetime of SARS-CoV-2
on various surfaces. The results suggest that SARS-CoV-2 do not require a saliva droplet to survive
although we have not found any evidence corroborating this. However, this time scale can be of interest
for frequently touched surfaces, e.g. door handles. In such settings, a droplet with a high viral load can
transfer from surface to skin by contact.

B.3.4 Modelling of droplet residue and how its mechanical performance and attachment
to surfaces could influence its survival

At the present time, there has been no micro-mechanical characterisation of the material properties of
partially-evaporated saliva droplets; however, if such properties were known then computational models

31
Figure 8: Illustration of skin stresses in shrinking droplets: for droplets in surface roughness grooves
(left) and droplets on a smooth surface (right). Notice that skin undulation or asymmetry potentially
mitigates against the surface tearing mechanism.

of droplets undergoing evaporation could be made. At some point during this process, the droplet would
first show higher viscosity, then become increasingly non-Newtonian as it transitions from being fluid-like
to becoming a gel, or solid-like. The morphology of the droplet during that process would be interesting
to study, particularly in regard to how the evaporation process drives the droplet shrinkage.
It is fairly obvious that a rough surface provides more surface area than a smooth one, and so a fluid
material spread over a rough surface would have more contact, and therefore be more greatly affected
by heat conduction between the surface and the fluid. Depending on the surface tension characteristics,
and how well the fluid wetted the surface, then there could also be greater fluid spread, and more area
available for evaporation.
The following is mere supposition, but illustrates how having a better understanding the material prop-
erties would yield a better understanding of viral survival and the effect of surface roughness in that
survival. Let us suppose that an outer layer of the droplet forms a skin or crust: an outer layer, exposed
to the air, and therefore more dried out by the evaporation process. Let us suppose that one action of
the skin is to protect or reduce evaporation of the inner material. Should that skin rupture, then the
inner material would become exposed, and that would then form a skin, and the volume of inner material
would be reduced. Encouraging the skin to rupture frequently could lead to faster evaporation and thus
to complete drying out. Depending on the adhesion strength of the droplet to the walls of roughness
grooves in the material, it is possible that the evaporation could lead to the skin becoming stretched
and tearing. The sort of modelling result that such analysis could provide are given in Figure 8, but
these are to be understood to be illustrative only, since the materials property data they are based on is
fabricated. If the virus requires some moisture to survive then devising ways of obtaining greater degrees
of drying would be beneficial to us.
Alternatively, the more important aspect might be the ease of which a part of the droplet can be adhered
to a finger and plucked from the surface. What are the relative adhesion strengths of the droplet to hard
surface, and droplet to finger? Does finger dampness play a role in this? When a droplet is picked up
on a finger in this way, is it transferred whole, or does a part remain stuck to the surface? If the latter
is the case, then presumably the moister inner material is then exposed, and perhaps the virus is more
readily transferred from the finger to other parts of the body, such as hand-to-face contact.
Given the potential value that credible geometrical, fluid and mechanical modelling could provide, micro-
scale materials characterisation would enable a much greater understanding of the physical processes
within the droplet, how the droplet is transferred, and how this influences the survivability of the virus
within the droplet.

32
B.4 Self-inoculation via hand-to-face contacts

For an individual to get infected after contact with a contaminated surface, self-inoculation with a
sufficient dose of the virus must occur. Typical hand-to-nose contact frequency occur about 2.5±2.2/hour
(Wilson et al., 2020b). A study by Nicas & Best (2008) reports observed frequency of contact between
individuals’ hands and mucous membranes (eyes, lips and nostrils) and a model to quantify the risk of
infection taking into account pathogen pick-up, inactivation on the hands with time and frequency of
contact between hands and mucous membranes. The data reported are based on seasonal Influenza A
virus.
Zhang & Li (2018) report a detailed study of transmission of Influenza A in a student office through
person-to-person contact and surface touch behaviour. The authors consider airborne and fomite-
mediated transmission pathways and report detailed data about surfaces and individuals involved includ-
ing close contact (enabling transmission through large droplets) and surface touch observations. Based
on a mathematical model describing both the aerosol and surface transmission pathways, the authors
conclude that 4.2% of risk of infection by Influenza A is due to transmission via fomites. On the other
hand, in the office 95.1% of viruses were transmitted via private surfaces and only 4.9% via public surfaces
with desks being the most contaminated due to virus-laden droplets generated while talking, sneezing
and coughing being deposited on desks (including computer keyboards, mice, etc. located on them).
It has recently been suggested that transmission through contact between a contaminated hand and the
eye may not be the preferred way of infection by SARS-CoV-2 (Liu & Sun, 2020).

B.5 Cleaning and disinfection

B.5.1 What is an effective detergent?

Soap and water has been widely recommended to remove the SARS-CoV-2 virus from surfaces and
skin. Chaudhary et al. (2020) investigates the mechanisms employed by the surfactants found in soap to
disrupt the virus and conclude that soap and water is effective against the virus. However, Chin et al.
(2020) implies that hand soap solution cannot inactivate the SARS-CoV-2 virus very well; that infectious
virus can be found after 5 minutes of incubating in hand soap solution. However, they have not simulated
hand washing and have simply added the virus culture to hand soap solution. The physical removal of
the virus trapped in soap micelle while rinsing hands has thus not been simulated in this study.

B.5.2 What is an effective disinfectant?

Kampf et al. (2020) reports that the following substances can readily inactivate the infectivity of
coronaviruses (by 4log10 or more): Ethanol (78%–95%), 2-propanol (70%–100%), 2-propanol (45%)
with 1-propanol (30%), glutardialdehyde (0.5%–2.5%), formaldehyde (0.7%–1%) and povidone iodine
(0.23%–7.5%).
Quaternary ammonium compounds (QAC) are known to be effective against both enveloped and non-
enveloped viruses and as such are a common additive to disinfectants. Although they exhibit a residual
biocidal effect over 2 to 4 hours after application which has been shown to be effective against norovirus,
it is unknown whether enveloped coronaviruses are susceptible at these lower concentrations. Sodium
hypochlorite requires a concentration of at least 0.2%, whilst hydrogen peroxide requires a concentration
of at least 0.5% and left incubating for at least 1 minute. Chlorhexidine digluconate has been found to
be ineffective against coronaviruses (Kampf et al., 2020). It has been highlighted that SARS-CoV-2 is an
enveloped virus and therefore can be less resistant to disinfection than non-enveloped viruses (Glasbey &
Whiteley, 2020). The United States Environmental Protection Agency has listed substances [see List N in
US EPA (2020)] that are potentially effective against SARS-CoV-2 (Glasbey & Whiteley, 2020). Neither
the substances in this list nor the substances in Kampf et al. (2020) have been experimentally proven
to be effective against SARS-CoV-2, although they have been proven for other strains of coronaviruses.
Appropriate procedure should begin with cleaning with soap and warm water followed by application of
a disinfectant in the above category.

33
B.5.3 Light deactivation

Dietz et al. (2020) reports that the impact of sunlight and UV light on the stability and decay of
SARS-CoV-2 has not yet been investigated. UV-C light has been proven to inactivate other strains of
coronaviruses within 10 minutes or less (Bedell et al., 2016). However, authors of this study state that UV-
C light is best employed alongside regular cleaning of surfaces, and use of light cannot simply substitute
effective cleaning practices. These measures also require thorough risk assessment and mitigation to
ensure that occupants’ health is not compromised and exposure is minimised.

B.6 Science behind current UK government advice

The UK government guidelines for cleaning of surfaces that are currently available do cite few scientific
articles regarding fomite transmission and we can therefore conclude that this pathway is thought to be
less significant than other transmission pathways.
The current government advice on cleaning in non-healthcare settings is to wipe hard surfaces with warm
soapy water before applying detergent. The guidelines lack definitions for both substances and only
suggest chlorine-based disinfectants. In this document, we have provided a list of potentially effective
detergents and disinfectants (mostly alcohol-based) that have been verified by experiments on other
strains of coronaviruses.
Waste that is suspected to be contaminated by COVID-19 should be stored for 72 hours before disposal.
This quarantine period also applies to returned goods in shops and clothes that have been tried on. We
assume that this duration is based on the results by van Doremalen et al. (2020) which suggest that
SARS-CoV-2 can remain active for 72 hours (see §B.2 on Factors affecting survival of virus on surfaces).
We are unable to find any guidelines on parcels.
Working safely during coronavirus (COVID-19) (link) contains sector-specific guidelines, including those
for transport, schools and childcare settings. These sectors have all been asked to clean ‘regularly and
frequently’—frequencies have not been quantified.

B.7 Conclusions and key questions

While there is still a lack of detailed and complete information regarding the behaviour of SARS-CoV-2
virus on surfaces, experimental studies have confirmed that certain environmental conditions (such as
high temperature and humidity) can reduce the stability of the virus, thus reducing infectivity. Further-
more, some studies have shown which disinfectants are potentially more effective against the virus than
others, what surfaces are typically infected, and for how long the virus remains on potentially infectious
on surfaces.
There is a lack of clarity in the UK government’s advice on what cleaning products and methods are
effective against the virus and which surfaces should be cleaned more frequently. In order to accurately
advise the public, as well as operators of key infrastructure, such as public transport and hospitals, it
is important to combine these experimental results with models that can be used to inform decision-
making. In order to build such models, information regarding the types of deposits on surfaces, the
concentration of the virus in these deposits, which surfaces are handled more frequently, as well as dose
response curves are vital.

C UVGI and COVID-19


With the emergence of COVID-19 and the subsequent global pandemic there has been considerable
interest in the use of UV light to disinfect blood plasma (Ragan et al., 2020; Keil et al., 2020; Eickmann
et al., 2020), medical equipment (Heimbuch & Harnish, 2019; Hamzavi et al., 2020; Card et al., 2020;
Derraik et al., 2020) and air (Morawska et al., 2020), in the hope that this might reduce transmission of
the disease. In particular, UVGI, a long established technology which utilizes UV-C light at wavelengths
close to 254 nm (Reed, 2010), appears to have considerable potential as an intervention for inactivating
SARS-CoV-2 (Inagaki et al., 2020; Beggs & Avital, 2020; Bianco et al., 2020) and other pathogenic

34
coronaviruses (Eickmann et al., 2020; Heimbuch & Harnish, 2019; Duan et al., 2003; Darnell et al., 2004;
Darnell & Taylor, 2006; Kariwa et al., 2006; Bedell et al., 2016).
The biological impact of UV radiation is primarily due to the absorption of energetic photons by nucleic
acids. DNA has an absorption spectrum which has a maximum in the 260 – 265 nm region, which
rapidly declines thereafter as the wavelength increases (Harm, 1980). At these wavelengths photons of
light are absorbed by nucleic acids, both DNA and RNA, to form dimers (fused base pairs) (Beggs, 2002)
that impair the replication of viruses, inhibiting their ability to cause infection. Dimers involving both
pyrimidines (cytosine and thymine) and purines (adenine and guanine) are the principal photoproducts
formed, with pyrimidine dimers, particularly those involving thymine, generally predominating (Jagger,
1967). The formation of these dimers inhibits transcription of the viral genome, thus preventing synthesis
of the necessary proteins required for the viral replication. The number of bases in the viral genome is an
important factor for determining sensitivity to UV damage, with longer genomes presenting more target
molecules, increasing the likelihood that the virus will be inactivated for a given level of UV exposure
(Sagripanti & Lytle, 2020). As such, the SARS-CoV-2 virus, having a genome that is almost twice as
long as the influenza viral genome, should in theory be more susceptible to UV damage than influenza.
Having said this, because both are RNA viruses and do not have thymine in their genome, they will both
tend to be less sensitive to UV damage compared to DNA viruses of similar genomic length.
While most work that has been undertaken on UVGI has involved low-pressure UV lamps with a strong
UV-C spectral emission at 253.7 nm, in recent years devices that produce light at other wavelengths have
also been investigated. Specifically, deep-UV (DUV) light emitting diodes (LEDs), which emit light at
around 280 nm on the boundary between UV-B and UV-C light, have been evaluated. With specific
reference to COVID-19, UV light from DUV-LEDs has been shown to inactivate the SARS-CoV-2 virus
in petri dishes (Inagaki et al., 2020). Others have also demonstrated that UV-C light at 222 nm can be
used effectively to inactivate coronaviruses in aerosols (Buonanno et al., 2020b).

C.0.1 UVGI inactivation Kinetics

At any point in time the amount of viral inactivation (disinfection) achieved for a given UV radiant flux
(irradiance) can be described using the following first order decay equation (McDevitt et al., 2012)

Nt = N0 × e−Z E t , (3)

where N0 and Nt are the number of viable viral particles (virions) at time zero and t seconds respectively;
Z is the UV susceptibility constant for the virus (m2 /J); E is the irradiation flux (W/m2 ); and t is time
in seconds.

The UV irradiation dose received by the virus is given simply by

H = E × t, (4)

where H is the observed UV irradiation dose (J/m2 ).


By combining equations 3 and 4, and rearranging we can obtain an equation for Z, namely
 
1 Nt 1
Z = − × ln = − × ln(f ) , (5)
H N0 H

where: f is the survival fraction.


Because the relationship between the UV dose and the natural logarithm of the survival fraction is
broadly linear for most viral species, it means that the behaviour of any given virus exposed to UV-C
light can be succinctly described by the value of Z, irrespective of the actual UV dose applied. As such,
for any given viral species, if the value of Z is known, then it should be possible to predict with reasonable
accuracy how the virus will behave when exposed to a given UV-C dose in any context. Microbes that
exhibit larger Z values are more susceptible to UV damage, whereas those with small Z values are more
difficult to inactivate.

35
UV inactivation plots for most viral species tend to be straight lines, although some might exhibit a
curve (Kariwa et al., 2006). Notwithstanding this, the model described in equation 3 is still a good
approximation for most viral species (McDevitt et al., 2012) up until the point where the ‘target’ be-
comes saturated with UV photons. At this point, because all the virions have already been inactivated,
increasing the UV dose further has no effect and so the linear relationship between UV dose and the log
reduction becomes decoupled, with the result that the Z value no long applies.
Instead of quantifying UV inactivation in terms of survival fraction, many researchers, particularly those
working in biology, describe the reduction in the microbial count in terms of log reduction, which can be
converted to survival fraction as follows
1
f= A, (6)
10
where A is the log10 reduction in the number of virions.

C.0.2 Susceptibility of SARS-CoV-2 to UVGI

While a substantial amount of work has been undertaken on the UV irradiation of coronaviruses in
various contexts (Inagaki et al., 2020; Bianco et al., 2020; Buonanno et al., 2020b; Walker & Ko, 2007),
relatively little work has been done specifically on the SARS-CoV-2 virus, and that which has been done
has focused solely on the irradiation of the virus on surfaces (Signify, 2020), in blood (Ragan et al.,
2020; Keil et al., 2020) or in liquids (Inagaki et al., 2020; Bianco et al., 2020). However, from the work
that has been done to date, a clear and consistent picture emerges, namely that in comparison with
SARS-CoV-1 and MERS-CoV, the SARS-CoV-2 virus appears to be relatively easy to inactivate with
UV-C light (Beggs & Avital, 2020). This is clearly illustrated in table 3, which shows the calculated
Z values for various UV-C (and deep-UV at 280 nm) irradiation experiments involving SARS-CoV-1,
MERS-CoV and SARS-CoV-2 suspended in liquids. From this, it can be seen that the adjusted mean Z
for SARS-CoV-1 was 0.00489 (SD = 0.00611) m2 /J, similar to that for MERS-CoV (Z value = 0.00104
m2 /J), whereas by comparison SARS-CoV-2 appears much more susceptible to UV damage at 254 nm
(adjusted mean Z = 0.14141 (SD = 0.09045) m2 /J) and 280 nm (mean Z = 0.03684 m2 /J).

While no irradiation experiments have yet been undertaken on SARS-CoV-2 virions in air, a few aerosol
experiments have been done using other related coronaviruses. The results of these experiments, together
with other selected viruses for comparison purposes, are listed in table 4. These reveal that compared to
influenza A (mean Z = 0.19435 m2 /J), the coronaviruses (Z = 0.377 m2 /J for murine (mouse) hepatitis
virus (MHV) coronavirus (Walker & Ko, 2007); 0.410 m2 /J for human coronavirus 229E (Buonanno
et al., 2020b); and 0.590 m2 /J for human coronavirus OC43 (Buonanno et al., 2020b)) are much more
susceptible to UV damage, which is perhaps only to be expected given that they have a genome that
is approximately twice the length of the influenza virus (Sagripanti & Lytle, 2020). Importantly, the
coronavirus Z values are an order of magnitude greater than those obtained for SARS-CoV-2 in liquid,
implying that when aerosolised, coronaviruses in general and SARS-CoV-2 in particular, are much easier
to disinfect compared with when they are presented in liquids or on surfaces. This however is to be ex-
pected as the medium in which microbes are irradiated greatly influences the magnitude of the Z value
achieved. This is because UV-C light is attenuated, due to scattering and absorption (Gregory, 2005),
as it passes through liquids (Mamane, 2008). Consequently, viruses are generally easier to disinfect in
the air compare with when they are on surfaces or in liquids.

Collectively, the results presented above strongly suggest that the SARS-CoV-2 virus is relatively easily
inactivated by UV-C light and that when aerosolised the virus is likely to exhibit a UV susceptibility
constant, Z, that is similar in magnitude to other coronaviruses in air. As such, this indicates that
SARS-CoV-2, when suspended in air, should be reasonably easy to inactivate using UV light at 254 nm.
As such, UVGI air disinfection applications appear to have potential as an intervention to inhibit the
transmission of COVID-19 in buildings and other enclosed spaces.

36
UV
UV-C dose Inactivation susceptibility
Virus Reference
(mJ/cm2 ) (log reduction) constant , Z
(m2 /J)
Duan et al. (Duan et al.,
SARS-CoV-1 >81 > log 0.602 0.00171
2003)
Darnell et al. (Darnell
SARS-CoV-1 241 log 1.4* 0.00134*
et al., 2004)
Darnell et al. (Darnell
SARS-CoV-1 1446 log 4.5* 0.00072*
et al., 2004)
Darnell & Taylor (Darnell
SARS-CoV-1 4819 log 4.1* 0.00020*
& Taylor, 2006)
Kariwa et al. (Kariwa
SARS-CoV-1 40 log 3.2* 0.01833*
et al., 2006)
Kariwa et al. (Kariwa
SARS-CoV-1 121 log 5.325 0.01017
et al., 2006)
Heimbuch & Harnish
SARS-CoV-1 1000 ≥ log 4.81 0.00111 (Heimbuch & Harnish,
2019)
Eickmann et al.
SARS-CoV-1 50 log 3.05 0.01405
(Eickmann et al., 2020)
Eickmann te al.
SARS-CoV-1 100 ≥ log 3.5 0.00806
(Eickmann et al., 2020)
Heimbuch & Harnish
MERS-CoV 1000 ≥ log 4.5 0.00104 (Heimbuch & Harnish,
2019)
Bianco at el. (Bianco
SARS-CoV-2 3.7 log 3.3 0.20536
et al., 2020)
SARS-CoV-2 5 log 2.0 0.09210 Signify (Signify, 2020)
SARS-CoV-2 22 log 6.0 0.06280 Signify (Signify, 2020)
Inagaki et al. (Inagaki
SARS-CoV-2 3.75** log 0.9 0.05526
et al., 2020)
Inagaki et al. (Inagaki
SARS-CoV-2 37.5** log 3.0 0.01842
et al., 2020)

Table 3: Calculated Z values for the UV-C (254 nm) and deep-UV (280 nm) irradiation experiments
involving coronaviruses suspended in liquids (Beggs & Avital, 2020).
* Estimated from plots and data presented in source material.
** Using deep-UV light at 280 nm (all other experiments performed using UV-C light at 254 nm).

37
Effective Z
UV-C
Researchers Virus value Reporter
wavelength
(m2 /J)
Kowalski et al.
Jensen (Jensen, 1964) Adenovirus 254 nm 0.0546 (Kowalski et al.,
2000)
Kowalski et al.
Jensen (Jensen, 1964) Coxsackie B-1 254 nm 0.1108 (Kowalski et al.,
2000)
Kowalski et al.
Jensen (Jensen, 1964) Influenza A 254 nm 0.1187 (Kowalski et al.,
2000)
Kowalski (Kowalski,
Jensen (Jensen, 1964) Sindbis virus 254 nm 0.1040
2010)
Kowalski et al.
(Jensen, 1964) Vaccinia virus 254 nm 0.1528 (Kowalski et al.,
2000)
Walker & Ko (Walker Walker & Ko (Walker
Adenovirus 254 nm 0.0390
& Ko, 2007) & Ko, 2007)
Walker & Ko (Walker Wolker & Ko (Walker
MHV coronavirus 254 nm 0.3770
& Ko, 2007) & Ko, 2007)
McDevitt et al. McDevitt et al.
(McDevitt et al., Influenza A 254 nm 0.2700 (McDevitt et al.,
2012) 2012)
McDevitt et al. McDevitt ct al.
(McDevitt et al., Vaccinia virus 254 nm 2.5400 (McDevitt et al.,
2007) 2007)
Buonanno et al. Buonanno et al.
(Buonanno et al., Human coronavirus 229E 222 nm 0.4100 (Buonanno et al.,
2020b) 2020b)
Buonanno et al. Buonanno et al.
(Buonanno et al., Human coronavirus OC43 222 nm 0.5900 (Buonanno et al.,
2020b) 2020b)

Table 4: Summary of reported effective Z values for single-pass UV-C irradiation experiments performed
on selected aerosolised viruses in air (Beggs & Avital, 2020)

38
C.1 UVGI air disinfection applications

While it is clear from the discussion above that the SARS-CoV-2 virus can be relatively easily inactivated
using UV-C light, this does not necessarily mean that installing UVGI air disinfection in buildings or
other enclosed spaces (e.g. passenger vehicle, trains, buses, etc.) will prevent the transmission of COVID-
19 in these facilities. This is because, in order to break the chain of COVID-19 transmission, UVGI needs
to be applied in a manner that: (i) is appropriate to the situation; (ii) targets the route of transmission;
and (iii) disinfects enough air to be effective. Too often do building owners and occupiers, seduced by
adverts claiming a ‘99.9% kill’ against an infectious pathogen, install expensive UVGI room air cleaners
in their facilities, only to find that they offer little or no protection at all. This occurs because the
impressive claims made by manufacturers often relate to single-pass microbiological tests (which may or
may not involve relevant microbial species) rather than addressing how the device will actually perform
in a given room space. So for example, a UVGI room air cleaner may inactivate (kill) every microbe that
passes through it, but if the air flow rate through the device is small, then it will have little impact on a
large, well ventilated, room space. Therefore, when considering UVGI air disinfection it is important to
evaluate its likely performance in the context of the room space, something which will inevitably involve
evaluation of room occupancy levels and the geometry of the room space, as well as consideration of the
ventilation system.
UVGI air disinfection devices can be broadly classified into:
• Upper-room UVGI systems in which an open UV-C irradiation field above the heads of room
occupants is used to disinfect aerosolised bacteria and viruses suspended in the air. Because UV-C
light is harmful to humans, such systems utilize louvres and baffles that obscure the UV lamps
from eyesight so that the room occupants are kept safe.
• In-duct UVGI systems which utilise UV-C lamps mounted in the return or supply air ducts of
mechanical HVAC systems to disinfect the air either to or from the room space.
• UVGI room air cleaners which are located within the room space and employ UV-C lamps
mounted in a container with a fan. These can vary in size, but only disinfect the air that passes
through the device.
A detailed discussion of each of the above UVGI variants follows in the sections below, so here we will
restrict ourselves to a broad discussion of some general principles that are applicable to all types of UVGI
air disinfection system.

C.1.1 Target microbes

Unlike air filters, which capture all particulates of a given size irrespective of their biological status,
UVGI air disinfection systems target specific microbes. They do not clean the air; rather they use
biophysical mechanisms to inactivate target viral and bacterial species, which once inactivated remain
in the air stream. Target microbes are generally viral or bacterial species that cause infectious disease.
So in the case of COVID-19, the target microbe is the SARS-CoV-2 virus. So when sizing a UVGI air
disinfection system to inhibit the transmission of COVID-19, it is necessary to ensure that any SARS-
CoV-2 virions in the air will receive a lethal dose of UV-C light, since a sub-lethal dose may leave some
virions infectious. In order to calculate the necessary lethal dose to be administered, it is first necessary
to use the appropriate Z value for the target microbe in an aerosolised state, and then, if possible, add
a factor of safety in order to ensure that the installation will adequately protect the room occupants. In
the case of COVID-19, although the precise Z value for SARS-CoV-2 in air is not known, Z values for
three other closely related coronaviruses in air have been determined (Buonanno et al., 2020b; Walker &
Ko, 2007). Of these, the Z value (0.377 m2 /J) for MHV coronavirus (Walker & Ko, 2007) is the lowest
value, implying that this is the most hardy of the three. It is therefore suggested that this is probably a
good candidate for the target Z value of SARS-CoV-2 in air (Beggs & Avital, 2020) as it is likely to be
a conservative value.

39
C.1.2 Safety

UV-C light is highly biologically active and as such can cause damage to humans. Furthermore, although
UV light is far more energetic than the visible portion of the electromagnetic spectrum, it is invisible
to humans, and so damage can occur without the individuals concerned noticing. Exposure to UV light
can result in transient corneal inflammation (photokeratitis) in the eye (Cullen, 2002), which may go
unnoticed, but may progress to include inflammation of the conjunctiva (photoconjunctivitis) (Grifoni
et al., 2005). Acute exposure to UV-C radiation can cause more severe corneal damage (Cullen, 2002),
which generally abates after several days, leaving no permanent damage (Cullen, 2002), although there
have been reports of clinical symptoms persisting for as much a two years after an acute UV injury (Zaffina
et al., 2012). For this reason, it is important to ensure that UV-C lamps are completely hidden from the
view of room occupants, either through total enclosure or the use of louvres or shields. In addition, in
order to protect the eyes, UV-C safety goggles should be worn when undertaking maintenance work on
UV systems.
UV-C light can also cause cutaneous damage (erythema) (Harrison & Young, 2002), resulting in reddening
of the skin akin to sunburn. In this respect, UV-C light is actually less effective than UV-B at causing
erythema because it has a lower penetration capability. More importantly, because prolonged exposure
to UV light is associated with cancer, doubts have been raised about the safety of upper-room UVGI
air disinfection systems due to the risk of exposure to reflected UV-C light. However, the International
Commission on Illumination (CIE) review of the subject found that upper-room UVGI air disinfection
could be safely used without significant risk for long-term delayed effects such as skin cancer (CIE, 2010).

C.1.3 What UVGI can and cannot do

Irrespective of the specific type of UVGI air disinfection used, it is important to be aware of the limitations
of the technology. While UVGI air disinfection can help to reduce the airborne (aerosol) transmission
of infectious diseases, it cannot protect against close range droplet transmission. So in the context
of COVID-19, this means that UVGI air disinfection cannot protect an individual if, for example, an
infected person coughs directly in their face. However, if upper-room UVGI is applied, it can protect
individuals from the many hundreds of smaller aerosol particles (generally <50 µm in diameter) that are
exhaled by room occupants, which can be readily transported on room air currents (Beggs, 2020). In
addition, when mounted in return air ductwork, UVGI lamps can also protect against infectious aerosol
particles being recirculated back into the room spaces through the mechanical ventilation system, if the
system recirculates a portion of the air in order to save energy.

C.2 Upper-room UVGI air disinfection

Upper-room UVGI, as the name suggests, involves the creation of an open field UV-C irradiation field
within the upper portion of a room as shown in figure 9. This can be done using either wall or pendant
fittings mounted at high level similar to those shown in figure 10. Since exposure to UV-C light can
be harmful, such devices are fitted with louvres or baffles, in order to prevent: (i) the occupants below
from seeing the lamps; and (ii) the UV light from penetrating into the lower room space. The goal of
upper room UVGI is to inactivate any infectious microbes (e.g. viruses and bacteria) that may pass
through the UV zone and thus disinfect the air inhaled in the lower room space. As such, upper-room
installations rely on natural convection currents, rather than fans, to carry aerosol particles through
the UV field. By using the convection currents that occur naturally in room spaces it is possible to
disinfect very large volumes of air relatively quickly (Miller et al., 1999). As such, upper-room UVGI air
disinfection is a well-established technology (First et al., 1999a,b) that has proven effective as a public
health intervention to prevent the spread of airborne diseases such as measles (Nardell & R., 2019) and
tuberculosis (TB) in buildings (Escombe et al., 2009; Noakes et al., 2006).

C.2.1 Calculating the required UV flux

Despite first being used in the 1930s (Reed, 2010), the guidelines for designing upper-room UVGI systems
are surprisingly sparse. This is primarily because the required UV-C radiant flux, E, is wholly dependent

40
Figure 9: An upper-room UVGI air disinfection installation

Figure 10: Typical wall mounted upper-room UVGI air disinfection fitting.

on the target microbe and the air movement characteristics of the room space, both of which may vary
greatly depending on the application being considered. Also, because most UVGI air disinfection activity
has focused on the eradication of TB (Coker et al., 2001), the guidelines which exist tend to be written
in the context of that disease and generally take a ‘rule-of-thumb’ approach. With respect to this, Table
5, which is taken from the ASHRAE UVGI air disinfection guidelines (ASHRAE, 2019), is typical of the
genre.

While to date no guidelines exist regarding upper-room UVGI and COVID-19, Beggs and Avital recently
produced a feasibility study (Beggs & Avital, 2020) to evaluate the potential efficacy of the technology
in this context. This study included a methodology (presented below) for estimating the upper-room
UV flux required to disinfect the SARS-CoV-2 virus in ventilated room spaces. This approach utilized
the methodology described in Beggs and Sleigh (Beggs & Sleigh, 2002) and assumed that the room air
is well mixed, which is a reasonable approximation for many applications (Beggs & Sleigh, 2002). If the

Wall-Mounted Wall-Mounted Ceiling-Mounted Ceiling-Mounted


Fixtures Fixtures Fixtures Fixtures
Corner Mount Wall Mount Pendent Pendent with Fan
Beam pattern 90◦ 180◦ 360◦ 360◦
Minimum ceiling height 2.44 m 2.44 m 2.89 m 2.89 m
Fixture mounted height 2.1 m 2.1 m 2.4 m 2.4 m
Ideal UV-C intensity (flux)
> 10 µW/cm2 > 10 µW/cm2 > 10 µW/cm2 > 10 µW/cm2
for effective disinfection

Table 5: Suggested installation summary for upper-room UVGI air disinfection (ASHRAE, 2019; Coker
et al., 2001)

41
space is well mixed, then the average particle residence time, tres , (in seconds) in the room will be
1
tres = × 3600 , (7)
n
where n is the room ventilation rate in air changes per hour (AC/hr).
From equation 7 it can be approximated that the average particle residence time in the upper-room UV
field, tuv , (in seconds) will be
huv
tuv = tres × , (8)
hr
where hr is the floor-to-ceiling height (m), and huv is the depth of the upper-room UV zone (m).
Because Z values are often determined experimentally using microbes suspended in liquids or on surfaces,
it may by necessary to adjust the Z value for use with upper-room UVGI systems (Beggs et al., 2006;
Yang et al., 2017), as follows
Zur = Z × cur , (9)
where Zur is the effective upper-room Z value (m2 /J), and cur is a correction coefficient.
Zur can be assumed to be the same as the aerosol Z value for the target microbe, examples of which are
presented in table 4.
So if we assume that the air in a room is well mixed, by combining equations 4, 5 and 8 it is possible to
compute the average irradiation flux (W/m2 ), Er , that is required to achieve a desired survival fraction,
f r.
1
Er = × ln(fr ) . (10)
(Zur × tuv )
In which case, the average UV dose received (J/m2 ), H r , is
Hr = Er × tuv . (11)
Alternatively, the disinfection achieved by an upper-room UVGI system can be thought of as being
equivalent to additional air changes in the room space (McDevitt et al., 2008). In this scenario, the
UV rate constant, kuv , which can be thought of as the equivalent air change rate per second, can be
determined using (Beggs et al., 2006), i.e.
huv
kuv = Zur × E × . (12)
hr

So in a ventilated room in which contamination ceases at time zero, we can utilize both the UV rate
constant, kuv , and a rate constant, kv , for the ventilation (i.e. n ÷ 3600), to produce a decay model for
the room space
Ct = C0 × e(kv +kuv +kd ) , (13)
where C0 and Ct are the concentrations of viable viral particles in the room space (virions/m3 ) at time
zero and t seconds respectively; kv is the ventilation rate constant; kd is the particulate deposition rate
constant (e.g. 0.0014 s−1 (Stadnytskyi et al., 2020)); and t is time in seconds.
Similarly, the following continuous contamination model represents the contaminant concentration in the
room space, Cuv , under steady-state conditions
q
Cuv = , (14)
(kv + kuv + kd ) × V )
where V is the room volume (m3 ), and q is the steady-state room contamination rate (virions/s).
Using this simple approach, it is possible to estimate:
• The average UV-C flux (µW/cm2 ), Er , required to achieve the desired level of inactivation in the
target microbe.
• The average UV-C dose (mJ/cm2 ), Hr , required to achieve the desired level of inactivation in the
target microbe.
• The equivalent air change rate per second, kuv , that can be achieved by the UVGI installation with
regard to the target microbe.

42
C.2.2 Upper-room UVGI feasibility study

Recently Beggs and Avital (Beggs & Avital, 2020) undertook a feasibility study to evaluate the potential
efficacy of the upper-room UVGI air disinfection as a measure to prevent the transmission of COVID-19
in a ventilated room space. In this study equations 8 and 10 were used to estimate the average upper-
room irradiation flux that would be required to achieve a 50 - 90% reduction in aerosolised SARS-CoV-2
virions (through the action of the UV-C alone) in a 4.2 × 4.2 × 2.5 m high room space for a range
of ventilation rates. These dimensions were chosen because they are typical for an upper-room UVGI
installation in which the lamp height is 2.1 m above the floor (First et al., 1999b). In the model it was
assumed that the air was completely mixed, which meant that according to equation 8, aerosol particles
would spend on average 16% of their room residency time in the UV zone.
In addition to computing the required UV flux, the performance of a standard upper-room UVGI fitting
was evaluated against the challenge of SARS-CoV-2. This was done in accordance with the guidelines
stated by First (First et al., 1999b), in which it was assumed that the room contained a single 30 W
(input) UV-C fitting capable of delivering an average upper-room flux of 50 µW/cm2 (ASHRAE, 2019),
with performance modelled in terms of equivalent ventilation rate using equation 12.
Because to date no UV irradiation experiments have been performed on aerosols containing the SARS-
CoV-2 virus, in the feasibility study the value of Zur was taken to be 0.377 m2 /J, which was the value
that Walker and Ko obtained for the MHV coronavirus in air (Walker & Ko, 2007). Because this was
considered a conservative value, it was selected as a suitable surrogate for SARS-CoV-2. In addition,
because of the uncertainty associated with this assumed value, a 10-fold ‘factor of safety’ was introduced
into the analysis by also modelling a worst-case scenario in which Zur was 0.0377 m2 /J.
Table 6 presents the results of the room analysis using these two values for Zur , for a range of ventilation
rates. From this it can be seen that there is a direct inverse relationship between particle residence time
in the UV field, tuv , and the required irradiation flux, Er , as predicted by equation 10. This means that
for any given Z value, the value of Er will double as the room ventilation rate doubles. The table also
reveals that there is a direct inverse relationship between Zur and Er . From the calculated values in this
table it can be seen that if Zur = 0.377 m2 /J, then with an average UV flux of just 10 µW/cm2 it should
be possible to achieve >90% inactivation of SARS-CoV-2, even at a ventilation rate of 8 AC/h. However,
if in reality, Zur , is 0.0377 m2 /J, then all the calculated fluxes would have to increase by a factor of ten
to achieve the same results. Given that accepted guidelines (First et al., 1999b) recommend for a room
2.5 m high, one 30 W (input) UV lamp per 18.58 m2 of floor area, which will produce an average flux in
the region 50 µW/cm2 , this means that even under this worst-case scenario it should still be possible to
achieve disinfection rates >90% for all but the highest ventilation rates.
When the UV flux was fixed at an average of 50 µW/cm2 , it was found that for Zur , = 0.377 m2 /J the
upper-room UVGI installation produced an equivalent air change rate of 108.6 AC/h, whereas if Zur ,
= 0.0377 m2 /J this fell to 10.9 AC/h. These values were constant and unaffected by the actual room
ventilation rate.
Collectively, the results from the feasibility study suggest that upper-room UVGI may have considerable
potential as an intervention against the transmission of COVID-19 in buildings, especially in situations
where achieving high ventilation rates might otherwise be impractical.

C.2.3 Room air movement and particle decoupling

While the results of the feasibility study are encouraging, it is important to remember that, unlike TB
which is spread via the inhalation of droplet nuclei <5-10 µm in diameter, COVID-19 can be transmitted
through the exhalation of larger respiratory droplets <100 µm, which rapidly reduce in size due to
evaporation (Beggs, 2020; Xie et al., 2007; Liu et al., 2017) to become aerosols say <50 µm in diameter
(Nicas et al., 2005). These aerosol particles have settling velocities <0.1 m/s and as such can readily
be transported on convective room air currents, with the result that they can remain suspended in
room air for many minutes. However, if the velocities of the convection currents drop, then some of the
larger aerosol particles may decouple from the air stream and settle out due to gravitational deposition,
potentially passing through the breathing zone where they can be inhaled by the room occupants. This
is particularly the case if the air is poorly mixed, and stagnant regions exist within the room space.
Under such circumstances larger aerosol particles may be inhaled without being fully irradiated by the

43
Average Average
Average Average
UV irradiance irradiance
particle irradiance
Ventilation rate susceptibility required for required for
residence time required for 90%
(AC/h) constant, Zur 50% 70%
in UV field. inactivation
(m2 /J) inactivation inactivation
(mins.) (µW/cm2 )
(µW/cm2 ) (µW/cm2 )
1 9.6 0.3770 0.319 0.554 1.060
2 4.8 0.3770 0.638 1.109 2.121
4 2.4 0.3770 1.277 2.218 4.241
6 1.6 0.3770 1.915 3.327 6.362
8 1.2 0.3770 2.554 4.436 8.482
1 9.6 0.0377 3.192 5.544 10.604
2 4.8 0.0377 6.384 11.088 21.207
4 2.4 0.0377 12.768 22.177 42.414
6 1.6 0.0377 19.152 33.266 63.621
8 1.2 0.0377 25.536 44.355 84.829

Table 6: Predicted average upper-room UV irradiance fluxes required to achieve 50%, 70% and 90%
inactivation for SARS-CoV-2 assuming a range of Zur values and ventilation rates. (Assuming Zur =
0.377 or 0.0377 m2 /J) (Beggs & Avital, 2020)

upper-room UV field, undermining the effectiveness of the whole UVGI installation. Consequently, if
upper-room UVGI is to be effective against COVID-19, it is important both to promote good room air
mixing and also to ensure that larger aerosol particles (e.g. 10-50 µm in diameter) receive a lethal UV
irradiation dose. As such, this may require upper-room UVGI systems to be supplemented with ceiling
mounted fans (Zhu et al., 2013) or other devices to promote the necessary air movement to ensure that
larger aerosol particles are adequately irradiated.
Upper-room UVGI air disinfection is highly dependent on good air mixing occurring between the upper
and lower portions of the room space (Beggs & Sleigh, 2002; Noakes et al., 2004b; Nicas & Miller, 1999).
In the feasibility study it was assumed that complete mixing occurred, which although a reasonable
approximation in many instances, is not always the case because short circuiting can occur (Beggs &
Sleigh, 2002). If the room air mixing factor, which describes the inter-zonal air flow rate relative to
the absolute room ventilation rate, is low, say for example due to stratification in a poorly ventilated
space, then this can greatly impair the disinfection performance of an upper-room UVGI system (Beggs
& Sleigh, 2002; Noakes et al., 2004b). It is therefore important when designing such systems to carefully
consider the air movement in the room space, in order to eliminate stagnant regions and maximise air
movement through the UV field. With this in mind analysis can be performed using either zonal models
(Noakes et al., 2004b,a) or computational fluid dynamics (CFD) (Zhu et al., 2013; Gilkeson & Noakes,
2013). Zonal models are relatively simple and easy to use, but limited in scope (Noakes et al., 2004a),
whereas CFD is much more flexible and comprehensive, but is computationally expensive, requiring
specialist skills and software to execute any models that are constructed.

C.3 In-duct UVGI air disinfection

Many older commercial HVAC and mechanical ventilation systems recirculate a portion (in the region 50
– 80%) of the room air in order to save energy. In the context of the COVID-19 pandemic this strategy
is potentially extremely hazardous because it means that aerosol particles containing the SARS-CoV-2
virus extracted from one location in a building may become widely distributed throughout the whole
building by the mechanical (recirculating) ventilation system. If this happens, then the HVAC system
could in effect become a pathogen distribution system. However, although in theory infectious aerosol
particles can be dispersed around buildings by this route, the clinical evidence in support of this opinion
is somewhat lacking, with for example, no evidence found to link the outbreak that occurred on the
Diamond Princess cruise ship in January 2020 with the ship’s central air conditioning system (Xu et al.,
2020). Nevertheless, the UK Health and Safety Executive (HSE) recommends: “You can continue using
most types of air conditioning system as normal. But, if you use a centralised ventilation system that
removes and circulates air to different rooms it is recommended that you turn off recirculation and use

44
a fresh air supply.” (HSE, 2020) and the Who Health Organization (WHO) states: “For mechanical
systems, increase the percentage of outdoor air, using economizer modes of HVAC operations and poten-
tially as high as 100%.” (WHO, 2020) While there may be controversy as to whether or not recirculating
HVAC systems contribute to the spread of COVID-19, there is strong clinical evidence implicating recir-
culated air in the transmission of TB, with an outbreak on a US naval vessel attributed to a recirculating
mechanical ventilation system, in which a single undiagnosed index case managed to infect 140 out of
308 crew members (Houk, 1980). Given the evidence from this case and the general lack of knowledge
surrounding COVID-19 transmission in buildings, it is therefore entirely understandable that the public
health authorities might wish to adopt a precautionary approach in relation to the recirculation of return
air.
Notwithstanding the above discussion, while it is possible in the UK to operate HVAC systems using
100% outside air during the summer months, the situation is very different in the winter months when
temperatures drop. This is because the heating coils in the air handling units (AHUs) in many instal-
lations do not have enough power to enable the supply air to be heated from, for example, –1o C to say
28o C. Consequently, if 100% outside air is supplied, then during periods in which the weather is cold,
many buildings might become uncomfortable and potentially uninhabitable. Consequently, making such
buildings both COVID-19 ‘safe’ and also comfortable is a major challenge. However, it is this precise
challenge to which in-duct UVGI air disinfection is particularly well suited. By installing UVGI lamps
in the return air duct-work it is possible to irradiate the target microbes and inactivate them before
they are recirculated back into the room space. In so doing, the UVGI lamps can in theory protect both
the room occupants and the AHU from cross-infection/contamination, while still enabling the system to
recirculate return air. So in the context of the COVID-19 pandemic, in-duct UVGI might be technology
that could be retrofitted into commercial HVAC systems in order to enable buildings to become fully
operational during the winter months.
In-duct UVGI air disinfection is also applicable to HVAC systems where thermal wheels are installed to
recover waste heat. While these systems negate the need for the recirculation of return air, there is still
the risk of cross-contamination with the SARS-CoV-2 virus because the wheel revolves between the two
air streams. Employing UVGI lamps in the return air stream before the wheel potentially might prevent
this from happening.

C.3.1 Where should in-duct UVGI lamps be placed?

In the context of the transmission of airborne disease (e.g. TB), while UVGI lamps can be placed in
either the return or supply air ducts, it is generally preferable to install the lamps on the return air side
of the AHU. This is because in this position, the UV field not only protects against pathogens being
recirculated, but also prevents the up-stream duct-work, filters and coils from becoming contaminated.
This is particularly important in the context of COVID-19 because coronaviruses can remain viable on
surfaces for several days (van Doremalen et al., 2020) and therefore may pose a threat to staff performing
maintenance duties. In addition, mounting the lamps on the return air duct before the AHU will also
protect anyone in the vicinity of the system exhaust air outlet.

C.3.2 Failing safe

With all UVGI systems it is important that they ‘fail safe’, so that building occupants are protected
should the lamps fail. For this reason ASHRAE recommend that in-duct UVGI should “always be used
in combination with proper filtration” (ASHRAE, 2019). In the context of COVID-19, this presents
a tricky problem. Because COVID-19 is caused by a virus, this would necessitate the installation of
HEPA filters, which would completely undermine the reason for retrofitting UVGI, namely to protect
the building occupants while keeping fan energy consumption low. Therefore, workable solutions need
to be developed to overcome this problem.

C.3.3 Computation of the UV flux

While in theory the UV-C dose received by a microbe passing through a UV field can be easily computed
using equation 4, in practice with in-duct systems, computation of the dose received can be complex.

45
Because the air velocities in mechanical ventilation ducts are relatively high, generally in the region 3-6
m/s, it means that residence times in the UV field are very short, generally <1 s. This means that in
order to administer a lethal dose the UV flux has to be very large, often requiring multiple high-powered
lamps. Consequently, without knowing the precise arrangement of the lamps and access to numerical
modelling techniques it is difficult to compute the dose that will be received by a target microbe. The
situation is further complicated by the fact that if the UV flux is not evenly distributed across the duct,
microbes passing through the periphery of the field may not receive a lethal dose. If this occurs, the
microbe may remain infectious, undermining the efficacy of the whole installation. As such, in order to
properly evaluate how a given in-duct UVGI air disinfection installation will perform, it is necessary to
employ CFD analysis (Capetillo et al., 2015, 2017; Yang et al., 2018). Although a rough estimate can
be obtained of how a proposed in-duct UVGI installation might perform, using standard mathematical
techniques (Beggs et al., 2000), without CFD or some other advanced numerical modelling technique, it
is not possible to be fully confident about any predictions made, unless of course experimental work is
carried out.
Given the complexity associated with designing in-duct UVGI air disinfection systems, it is perhaps
not surprising that few guidelines exist regarding this type of installation (ASHRAE, 2019; Kowalski
& Bahnfleth, 2004), with those that do exist being somewhat vague. For example, regarding in-duct
UVGI the ASHRAE guidelines simply state: “The required average irradiance for a typical in-duct
system is on the order of 1000 to 10,000 µW/cm2 , but it could be higher or lower depending on the
application requirements.” (ASHRAE, 2019) Because it is difficult for building owners and consultant
engineers to perform the necessary in-duct UVGI calculations, they are forced to rely on the claims
made by manufacturers regarding the performance of their equipment. Consequently, there is need for
the manufacturers of UVGI air disinfection equipment to undertake robust microbiological testing, as
well as fully characterising the UV fields produced by their devices.

C.4 UVGI room air cleaners

Many manufacturers make ‘UV-C in a box’ style air disinfection devices for use in room spaces. These
devices essentially comprise UV-C lamps or LEDs mounted in a container with a fan. They are generally
free-standing units designed to disinfect all the air that passes through the device. As such, manufacturers
frequently make claims akin to ‘the unit achieves a 99.9% disinfection rate’ based on a ‘single-pass’
microbiological test. These claims can be however extremely misleading, because they relate purely to
the air that passes through the UV device and not to the effect that the unit will have on the room
space, which can be calculated for steady-state using
q
C= , (15)
v̇r + (v̇uv × η)

where C is the contaminant concentration in the room space under steady-state conditions (e.g.
(virions/m3 ), q is the steady-state room contamination rate (virions/s), v̇r is the room ventilation rate
(m3 /s), v̇uv is the air flow rate through the UV air cleaner (m3 /s), and η is the single-pass efficiency of
the air disinfection device expressed as a fraction.
From equation 15 it can be seen that if the room ventilation rate is large in comparison to the amount
of air flowing through the UV air cleaner, then even if all the air passing through the unit is 100%
disinfected, the overall impact of the device on the room space will be minimal. So unless the air cleaner
delivers a high air flow rate, or alternatively the room is very poorly ventilated, devices like this are
unlikely to have a major impact on the transmission of COVID-19 when employed in large spaces.
Notwithstanding the discussion above, if used in small poorly ventilated spaces, or in conjunction with
partitions, then small UVGI room air cleaners may be effective in protecting individuals against COVID-
19. Consider for example, a communal office desk that has been partitioned with screens (i.e. creating
booths) in order to minimise spread of COVID-19. If local air cleaning devices could be developed that
disinfected the air within the individual spaces created by the desk partitions, then this might provide
additional protection to individual workers. However, the feasibility of this would need to be verified
either through CFD analysis or experimental work.

46
C.5 Discussion

The principal findings of this Appendix are that:


• The SARS-CoV-2 virus is susceptible to damage from UV-C light and as such can be relatively
easily inactivated using UVGI.
• The SARS-CoV-2 virus appears to be particularly vulnerable to UV-C light when aerosolised and
as such, may (in theory) be readily disinfected using upper-room UVGI air disinfection.
• If retrofitted to recirculating HVAC installations, in-duct UVGI air disinfection may potentially be
a useful technology for enabling commercial buildings to function during the winter months of the
COVID-19 pandemic.
• With respect to COVID-19 transmission, no suitable guidelines exist regarding UVGI air disinfec-
tion.
When considering the above findings it is important to note the caveats “in theory” and “potentially”.
These have been inserted because although there is strong evidence that the SARS-CoV-2 virus is
susceptible to UV-C light, suggesting that UVGI air disinfection has considerable potential, there still is
much doubt about how the technology should be applied in order to protect the occupants of buildings.
While this doubt stems, in part, from an incomplete understanding of the mechanisms by which COVID-
19 is transmitted, it is also due to inherent issues associated with the technology itself, which make its
application difficult, as evidenced by the lack of detailed guidelines on the design of UVGI air disinfection
systems. These inherent drawbacks relate specifically to: (i) the fact that the design of UVGI air
disinfection systems is strongly influenced by the choice of the target microbe; and (ii) difficulty in
predicting how any given installation will behave without the use of complex simulation tools like CFD.
This makes it difficult to produce robust guidelines that are applicable to all situations. For example,
the guidelines applicable to, say, the transmission of TB in hospitals, might not be suitable for protecting
against the spread of COVID-19 in bars and music venues. Furthermore, once an air disinfection system
is installed it is difficult, without extensive microbiological testing or a clinical trial, to tell whether
or not the air disinfection system is actually protecting the occupants against infection. Collectively,
these factors have greatly inhibited the uptake of UVGI air disinfection, with the result that many are
suspicious of the technology.
Notwithstanding the above discussion, the results of the feasibility study by Beggs and Avital (Beggs &
Avital, 2020) suggest that upper-room UVGI air disinfection may well have a role to play in preventing
the transmission of COVID-19 in some settings. However, much remains unknown about the limits of
this technology with regard to COVID-19. Upper-room UVGI was primarily developed as an intervention
against ‘true airborne’ diseases such as TB, where the infectious particles are <5-10 µm in diameter.
However, COVID-19 is not a ‘true airborne’ disease in the classical sense, insomuch as it can also be
transmitted by inhalation of aerosol droplets in the range 10-100 µm. Depending on their size and room
air velocities, these larger aerosol particles can readily become suspended in the air and be dispersed
around the room space. While many of these airborne particles are transported by convection currents
to the upper part of the room space, some particles, due to their mass, may decouple from convective air
streams and settle out due to gravitational deposition. In doing so they may fall through the breathing
zone, where if they have not been fully inactivated by the UV field, they will be a potential hazard. So
while it is undoubtedly the case that upper-room UVGI can help to inhibit the spread of some COVID-
19, the extent to which it can be effective is not known and there is urgent need for CFD analysis work
to evaluate how the technology can be adapted to be effective against COVID-19. In particular, there is
a need to explore the use of room mounted fans in conjunction with UVGI air disinfection to promote
better air movement between upper and lower room zones.
Given the urgent need for a solution, which will make commercial properties (offices, shops, pubs, etc.)
and public buildings (schools, universities, etc.) COVID-19 safe as well as habitable during the winter
months, perhaps the most promising potential application of UVGI air disinfection is as a retrofit for
recirculating HVAC systems. By installing in-duct UVGI in the return air duct-work it should be possible
to permit the recirculation of air while ensuring that SARS-CoV-2 virions are not recirculated. However,
while this retrofit solution should not increase fan power consumption, the installation of UV-C lamps
might considerably increase electrical power consumption, something which may make UVGI unfeasible.
In addition, any requirement for ‘fail safe’ filters might also make in-duct UVGI untenable.

47
Because the performance of UVGI air disinfection installations is difficult to validate, architects, engineers
and building owners are generally forced to rely on claims made by equipment manufacturers. However,
the evidence base on which these claims are made, particularly those relating COVID-19, is often very
weak, with little or no microbiological testing involving viruses undertaken. Consequently, commissioning
bodies such as the NHS and government departments are reluctant to accept these claims without
substantial clinical (biological) evidence, thus inhibiting the general uptake of UVGI air disinfection. As
a result, there is urgent need for manufacturers of UVGI systems to undertake appropriate microbiological
testing of their products so that they can demonstrate their efficacy against the SARS-CoV-2 virus.
Regarding UVGI air disinfection, the guidelines that exist (ASHRAE, 2019; First et al., 1999a,b; Coker
et al., 2001), which were largely developed to control the spread of TB (Coker et al., 2001), tend to be
rather vague on technical issues, preferring instead to take a ‘rule-of-thumb’ approach. In particular,
the guidelines take little or no account of room air flow patterns, which (as discussed above) are crucial
to the performance of upper-room UVGI with respect to COVID-19 transmission. Consequently, these
guidelines cannot be relied upon in the context of COVID-19 and as a result there is urgent need to
develop new guidelines that are focused on this disease.

C.6 Conclusions

The conclusions regarding UVGI are:


• There is strong evidence that the SARS-CoV-2 virus can be inactivated by irradiation with UV-C
light and that the virus is particularly vulnerable to UV damage when aerosolised.
• There is good theoretical evidence to suggest that upper-room UVGI might be effective at disin-
fecting the SARS-CoV-2 virus in room air.
• While in theory upper-room UVGI can militate against COVID-19 transmission in enclosed spaces,
because larger aerosol particles (i.e. 10-100 µm in diameter) can decouple from room air convection
currents, it may be that additional supplementary air movement devices (e.g. room mounted fans,
etc.) will be needed to ensure good air disinfection.
• In-duct UVGI air disinfection could potentially be a useful technology for enabling commercial
buildings to function during the winter months of the COVID-19 pandemic.
• There is urgent need for a robust evidence base regarding UVGI air disinfection. In particular,
because it is difficult to predict how UVGI equipment will perform in any given context, there is
heavy reliance on the claims made by manufacturers. As such, there is urgent need for manufac-
turers of UVGI equipment to undertake appropriate microbiological testing so that end users can
be confident that their products will work effectively against the SARS-CoV-2 virus.
• There is urgent need to develop robust methodologies for validating the performance of UVGI air
disinfection systems, in order to demonstrate that they work (i.e. prevent the spread of COVID-19
in buildings).
• There is a need for suitable guidelines regarding the design and use of UVGI air disinfection systems
in the context of COVID-19.

D Summary of current recommendations for the use of face


masks or coverings (August 2020)
Face covering and masks have been demonstrated to prevent the transmission of the COVID-19 virus
(§2.3) especially in settings where there is reduced physical distancing. Face shields may protect against
droplets and the spread of droplets containing the virus, but not the transmission of aerosols. There is
emerging evidence that face coverings and masks may provide some protection by reducing the dose of
SARS-CoV-2 received. Face coverings have become mandatory within many indoor settings, including
shops and on public transport in the UK, where there is risk of decreased social distancing (DHSC,
2020). Face masks and coverings may represent the simplest and most cost effective method available to
employers to protect their employees if remote/home working is not feasible.

48
The evidence face masks and coverings will probably improve with time, however public guidance in the
UK on masks and face covering usage is likely to change from that written below. Please ensure you
check the local and current guidance for up to date information of face coverings. The links / references
used below may still be relevant to UK guidance.
For employers (within offices, etc)
The UK Government state within their office guidance (BEIS, 2020) that “there is growing evidence
that wearing a face covering in an enclosed space helps protect individuals and those around them from
COVID-19”. They also state “minimising time spent in contact, using fixed teams and partnering for
close-up work, and increasing hand and surface washing” and that “these other measures remain the
best ways of managing risk in the workplace”
However, given the time spent within other indoor settings, including shops and public transport may
be less than within offices, etc., and that distancing is likely to be difficult with an office. Perhaps
consideration should be given to the protection of a workforce by the recommending the use face coverings
or masks by employers.
P
(Jones et al., Pre-print) demonstrates that the amount of virus inhaled by a susceptible person ( n)
in the presence of an infector is particularly affected by the respiratory rate of a susceptible person, the
emission rate of RNA copies, the exposure
P time, the space volume, and the removal rate. A sensitivity
analysis showsPthat predictions of n in the reference space are most sensitive to the emission rate of
RNA copies. n is linearly related to the emission rate and so public health messages to encourage
self isolation when exhibiting symptoms of COVID-19 and the wearing of face coverings indoors are
important.
Within universities
No specific advice is given on the UK government for universities. The Scottish Government (Scottish
Government, 2020a) state: “universities will consider and plan around: availability and public health
advice on PPE, other equipment and/or face coverings appropriate to the activity or location.”
Similar to the above situation (for employers) any indoor space represents a risk of transmission. Con-
sideration should be given to the protection of students, teachers, lecturers and other staff by the rec-
ommending the use face coverings or masks.
For schools and colleges
“Public Health England does not recommend the use of face coverings in nurseries, childminders, schools
or colleges”. However, the Scottish Government (2020b) in-line with WHO recommendation advises high
school children (12 years and older) “should use face covering between classes, in secondary schools, by
adults and all pupils moving around the school, such as in corridors and communal areas where physical
distancing is difficult to maintain.” The guidance (DoE, 2020b) also notes if a child has been using a
face covering on public transport or on dedicated school transport that the covering must be removed
upon arrival at the school. More recent DofE guidance (DoE, 2020a) allows discretionary use of face
coverings for pupils in Year 7 and above where social distancing cannot be safely managed, and this will
be mandated in areas where local restrictions apply.
The risk to children though much lower, is well documented. Their asymptomatic transmission is also
well documented, which likely puts the teaching and other staff at increased risk, as well as the parents.
Yet it cannot be recommended to go against the advice given. Many European countries have reopened
schools without serious issues and without masking children (as of August 2020)
NOTE: Advice in Wales for face coverings and masks differs slightly from the other UK countries.

E Aerosols in the context of singing, and woodwind & brass


musical instruments
Music is an important part of our cultural heritage as well as providing or supporting much of the
entertainment industry. While recognising the importance of the activities of professional musicians and
singers and the organisations which employ them, it is important to note that the student and amateur
musical scene represents a much larger number of people.

49
For professionals, students and amateurs alike, the mechanics of playing or singing are similar, and so
measurement of the aerosol risks can be considered in a similar way. There are some significant differences
in regard to the impact to the community and environment in which the aerosol is likely to be produced,
namely:
• Professionals and conservatoire level students are likely to be spending greater periods of time
playing in both rehearsal and performance settings and be sharing a performance venue with a
very much larger and more mixed audience than is the case for amateurs.
• Outdoor performance by amateur woodwind and brass groups is common, particularly during the
summer months. Some amateur groups are choosing to rehearse outdoors at the present time.
• Shared use or short-term loan of an instrument is common for early level students, and in some
amateur groups. This is also an issue for pre-sale trial of instruments.
• Amateur musical groups include early level students, people of advanced age, and people with
pre-existing health conditions.
The need for improving the safety of indoor rehearsal and performance is well understood, and research to
measure the level of aerosol created during performance is being undertaken, so that risks from musicians
and singers can be compared with the risks of other performers such as orators, actors, dancers and sports
competitors. Currently, the only published and peer-reviewed report is that on the vuvuzela by Lai et al.
(2011). A substantially more thorough study carried out by Gregson et al. (2020) comparing aerosols
produced in singing, speaking and breathing is now available on the pre-print server ChemRxiv. A further
piece of work by the same authors investigating aerosol production in musical instruments is expected
to be released in the near future (Costello & Lang, 2020). Another major study is in preparation at
Colorado State University (Volckens et al., 2020). More informal studies have been carried out by a
number of organisations (Bamberger Symphoniker, 2020; Brandt, 2020; The Vienna Philharmonic, 2020;
Kähler & Hain, 2020; Performing Arts Aerosol Study, 2020).
When such aerosol production is better understood, appropriate ventilation and protection measures for
concert halls, theatres and arenas can then be designed. Organisations which represent professionals and
amateurs, and also those which represent performance venues, are already producing extensive guidelines
on the operational logistics of rehearsal and performance (Orchester.ch, 2020; Brass Bands England, 2020;
Musicians’ Union, 2020).
Outdoor performance presents less risk than indoor, particularly where mitigations, such as socially
distanced seating of the players and separation from the audience or passers-by, are upheld. Mitigations
for indoor playing consider issues of ventilation, and numbers of players in a room of a given volume.
Other mitigations that have been suggested, but for which the efficacy has not yet been established,
involve the wearing of a mask while playing, with a hole cut for the mouthpiece; and the use of a
covering to trap aerosols exiting from the end of the instrument. All such mitigations are undesirable:
outdoor performance feels unsatisfactory without the venue reverberation and musicians would usually
choose to sit close to each other to hear each other better; wearing a mask while playing will impact on
the player’s ability to perform; and covers on instruments reduce the sound level and can also impact on
tuning and sound quality.
It should also be noted that a person moving through a room can create a wake or cause settled par-
ticulates to be resuspended in the air. Musicians who make large body movements may contribute to
this effect, so whilst percussion, string players and conductors do not blow their instruments their bodily
movements may contribute to the redistribution of aerosol around a rehearsal or performance space.
This is illustrated in the string player photographs in The Vienna Philharmonic (2020) where the bow
movement entrains the flow.
For woodwind and brass instruments, the player’s breath drives the sound production, and breath gen-
erated aerosols will be carried through the instrument. Some of that aerosol load would be captured
within the instrument as condensation. In brass instruments, which are not perforated with finger holes,
and have lengthy and convoluted pipework, such condensation might be expected to be more complete
than in shorter woodwind instruments. Notwithstanding this, condensation cannot be relied upon as a
means to reduce aerosol when the instrument is warm, or being played in a warm environment.
Since the interior of an instrument can become contaminated if played by an infected player, the issue of
effective cleaning of loan or trial instruments is important. An approach might be to place each player

50
on a track and trace register after each loan or trial, or apply a quarantine period to the instrument. If
the instrument is needed sooner, or if a player develops COVID-19, then, where feasible, it could be put
through a chemical cleaning cycle. Metallic instruments and student grade plastic instruments might
tolerate such treatment, but quality wooden instruments would not.
There is considerable ongoing research in this area at the present time, and it may be some time before
complete peer-reviewed reports are available. Some reports cited here are media press reports.

51
References
Anfinrud, P., Stadnytskyi, V., Bax, C. E. & Bax, A. 2020 Visualizing speech-generated oral fluid
droplets with laser light scattering. N. Engl. J. Med. .
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M. & Ristenpart, W. D.
2019 Aerosol emission and superemission during human speech increase with voice loudness. Sci. Rep.
9 (1), 1–10.
ASHRAE 2019 Ultraviolet air and surface treatment, Chapter 62, 2019 ASHRAE Handbook—HVAC
Applications. American Society of Heating, Refrigeration and Air Conditioning Engineers.
Bahl, P., Doolan, C., de Silva, C., Chughtai, A. A., Bourouiba, L. & MacIntyre, C. R.
2020 Airborne or Droplet Precautions for Health Workers Treating Coronavirus Disease 2019? The
Journal of Infectious Diseases .
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E. & Olin, A. 2019 Exhaled particles and
small airways. Respir. Res. 20 (1), 8.
Bamberger Symphoniker 2020 Wissenschaftler messen aerosolausstoß. Bayern (Bavaria)
BR24 Nachricten https://www.br.de/nachrichten/bayern/bamberger-symphoniker-
wissenschaftler-messen-aerosolausstoss,Ry6T6OU, 5 May.
Bedell, K., Buchaklian, A. H. & Perlman, S. 2016 Efficacy of an automated multiple emitter
whole-room Ultraviolet-C disinfection system against coronaviruses MHV and MERS-CoV. Infection
Control and Hospital Epidemiology 37 (5), 598–599.

Beggs, C. 2002 A quantitative method for evaluating the photoreactivation of ultraviolet damaged
microorganisms. Photochemical & Photobiological Sciences 1, 431–437.
Beggs, C. 2020 Is there an airborne component to the transmission of COVID-19?: a quantitative
analysis study. medRxiv .

Beggs, C., Kerr, K., Donnelly, J., Sleigh, P., Mara, D. & Cairns, G. 2000 Disinfection efficacy
of ultraviolet germicidal irradiation on airborne bacteria in ventilation ducts. Transactions of the Royal
Society of Tropical Medicine and Hygiene 94, 141–146.
Beggs, C., Noakes, C., Sleigh, P., Fletcher, L. & Kerr, K. 2006 Methodology for determining
the susceptibility of airborne microorganisms to irradiation by an upper-room UVGI system. Journal
of Aerosol Science 37, 885–902.
Beggs, C. & Sleigh, P. 2002 A quantitative method for evaluating the germicidal effect of upper room
UV fields. Journal of Aerosol Science 33, 1681–1699.
Beggs, C. B. & Avital, E. J. 2020 Upper-room ultraviolet air disinfection might
help to reduce COVID-19 transmission in buildings. PeerJ, see also medRxiv , arXiv:
https://www.medrxiv.org/content/early/2020/06/14/2020.06.12.20129254.full.pdf.
BEIS 2020 Working safely during coronavirus (COVID-19) - guidance - gov.uk.
Bhamidipati, N. & Woods, A. W. Under review The mixing of airborne contaminants by the wake
of people. Interface .

Bhardwaj, R. & Agrawal, A. 2020 Likelihood of survival of coronavirus in a respiratory droplet


deposited on a solid surface. Physics of Fluids 32 (6), 061704.
Bianco, A., Biasin, M., Pareschi, G., Cavalleri, A., Cavatorta, C., Fenizia, C. & et al. 2020
UV-C irradiation is highly effective in inactivating and inhibiting SARS-CoV-2 replication. medRxiv .

Biryukov, J., Boydston, J. A., Dunning, R. A., Yeager, J. J., Wood, S., Reese, A. L., Fer-
ris, A., Miller, D., Weaver, W., Zeitouni, N. E., Phillips, A., Freeburger, D., Hooper,
I., Ratnesar-Shumate, S., Yolitz, J., Krause, M., Williams, G., Dawson, D. G., Herzog,
A., Dabisch, P., Wahl, V., Hevey, M. C. & Altamura, L. A. 2020 Increasing temperature and
relative humidity accelerates inactivation of SARS-CoV-2 on surfaces. mSphere 5 (4).

52
Bolashikov, Z. & Melikov, A. 2009 Methods for air cleaning and protection of building occupants
from airborne pathogens. Build Environ. 44, 1378–1385.
Bolster, D. T. & Linden, P. F. 2008a Particle transport in low energy ventilation systems. Part 1:
theory of steady states. Indoor Air 19, 122–129.
Bolster, D. T. & Linden, P. F. 2008b Particle transport in low energy ventilation systems. Part 2:
transients and experiments. Indoor Air 19, 130–144.
Boone, S. A. & Gerba, C. P. 2007 Significance of fomites in the spread of respiratory
and enteric viral disease. Applied and Environmental Microbiology 73 (6), 1687–1696, arXiv:
https://aem.asm.org/content/73/6/1687.full.pdf.
Bourouiba, L. 2020 Turbulent gas clouds and respiratory pathogen emissions: potential implications
for reducing transmission of COVID-19. Jama 323 (18), 1837–1838.
Bourouiba, L., Dehandschoewercker, E. & Bush, J. 2014 Violent expiratory events: on coughing
and sneezing. J. Fluid Mech. 745, 537–563.
Bowden, F. P. & Tabor, D. 1950 The Friction and Lubrication of Solids. Oxford University Press.
Brandt, L. 2020 Measurement of aerosol from brass and woodwind instruments playing 5 minutes in
distances from 0.5 to 4 meter. Odense University Hospital, University of Southern Denmark (non-peer
reviewed report) .
Brass Bands England 2020 Covid-19 advice, guidance and resources. Brass Bands England Website
https://www.bbe.org.uk/what-we-do/covid-19-advice-guidance-and-resources.
Buonanno, G., Stabile, L. & Morawska, L. 2020a Estimation of airborne viral emission: Quanta
emission rate of SARS-CoV-2 for infection risk assessment. Environment international 141, 105794.
Buonanno, M., Welch, D., Shuryak, I. & Brenner, D. 2020b Far-uvc light (222 nm) efficiently
and safely inactivates airborne human coronaviruses. Sci. Rep. 10, 1–8.
Burridge, H. C., Fan, S., Jones, R. L., Noakes, C. J. & Linden, P. F. Under review Airborne
infection R-numbers for regularly attended spaces: COVID-19 a case-study. Indoor Air https: //
arxiv. org/ abs/ 2009. 02999 .
Capetillo, A., Noakes, C. & Sleigh, P. 2015 Computational fluid dynamics analysis to assess
performance variability of in-duct UV-C systems. Science and Technology for the Built Environment
21, 45–53.
Capetillo, A., Noakes, C. & Sleigh, P. 2017 Cfd analysis to assess performance of multi-lamp
in-duct uvgi air disinfection systems. In Proceedings of Healthy Buildings Europe 2017 . International
Society of Indoor Air Quality and Climate (ISIAQ).
Card, K., Crozier, D., Dhawan, A., Dinh, M., Dolson, E., Farrokhian, N. & et al. 2020
Uv sterilization of personal protective equipment with idle laboratory biosafety cabinets during the
COVID-19 pandemic. medRxiv .
Casanova, L. M., Jeon, S., Rutala, W. A., Weber, D. J. & Sobsey, M. D. 2010 Effects of air
temperature and relative humidity on coronavirus survival on surfaces. Applied and Environmental
Microbiology 76 (9), 2712–2717.
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves,
M., Mengersen, K., Corbett, S., Li, Y., Xie, X. & Katoshevski, D. 2009 Characterization of
expiration air jets and droplet size distributions immediately at the mouth opening. Journal of Aerosol
Science 40 (2), 122–133.
Chaudhary, N. K., Chaudhary, N., Dahal, M., Guragain, B., Rai, S., Chaudhary, R.,
Sachin, K., Lamichhane-Khadka, R. & Bhattarai, A. 2020 Fighting the SARS-CoV-2 (COVID-
19) pandemic with soap. Preprints 2020050060.
Chen, W., Zhang, N., Wei, J., Yen, H.-L. & Li, Y. 2020 Short-range airborne route dominates
exposure of respiratory infection during close contact. Building and Environment 176, 106859.

53
Chia, P. Y., Coleman, K. K., Tan, Y. K., Ong, S. W. X., Gum, M., Lau, S. K., Sutjipto, S.,
Lee, P. H., Son, T. T., Young, B. E., Milton, D. K., Gray, G. C., Schuster, S., Barkham,
T., De, P. P., Vasoo, S., Chan, M., Ang, B. S. P., Tan, B. H., Leo, Y. S., Ng, O.-T.,
Wong, M. S. Y. & Marimuthu, K. 2020 Detection of Air and Surface Contamination by Severe
Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospital Rooms of Infected Patients.
medRxiv p. 2020.03.29.20046557.
Chin, A., Chu, J., Perera, M., Hui, K., Yen, H.-L., Chan, M., Peiris, M. & Poon, L. 2020
Stability of SARS-CoV-2 in different environmental conditions. medRxiv p. 2020.03.15.20036673.
Choudhary, R., Bafna, S., Heo, Y., Hendrich, A. & Chow, M. 2010 A predictive model for
computing the influence of space layouts on nurses’ movement in hospital units. Journal of Building
Performance Simulation 3, 171–184.
Chu, D. K., Akl, E. A., Duda, S., Solo, K., Yaacoub, S., Schünemann, H. J., El-harakeh,
A., Bognanni, A., Lotfi, T., Loeb, M. & others 2020 Physical distancing, face masks, and
eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: a systematic
review and meta-analysis. The Lancet .
CIBSE 2005 Natural ventilation in non-domestic buildings: CIBSE Applications Manual AM10 . Char-
tered Institution of Building Services Engineers.
CIBSE 2015 Chartered Institution of Building Services Engineers (CIBSE) Guide A: Environmental
design.
CIE 2010 Uv-c photocarcinogenesis risks from germicidal lamps. Tech. Rep.. Commission Internationale
de L’Eclairage, Publication 187:2010.
Coker, I., Nardell, E., Fourie, B., Brickner, P., Parsons, S., Bhagwandin, N. & Onye-
bujoh, P. 2001 Guidelines for the utilisation of ultraviolet germicidal irradiation (uvgi) technology
in controlling the transmission of tuberculosis in health care facilities in south africa. Pretoria (South
Africa): South African Centre for Essential Community Services and National Tuberculosis Research
Programme, Medical Research Council pp. 1–40.
Costello, D. & Lang, K. 2020 Covid-19 risk from singing. Front Row, BBC Radio 4 p. 20 August.
Cullen, A. P. 2002 Photokeratitis and other phototoxic effects on the cornea and conjunctiva. Inter-
national journal of toxicology 21 (6), 455–464.
Darnell, M., Subbarao, K., Feinstone, S. & Taylor, D. 2004 Inactivation of the coronavirus that
induces severe acute respiratory syndrome, SARS-CoV. Journal of virological methods 121, 85–91.
Darnell, M. & Taylor, D. 2006 Evaluation of inactivation methods for severe acute respiratory
syndrome coronavirus in noncellular blood products. Transfusion 46, 1770–1777.
DepartmentforEducation 2018a BB 101: Ventilation, thermal comfort
and indoor air quality 2018. https://www.gov.uk/government/publications/
building-bulletin-101-ventilation-for-school-buildings.
DepartmentforEducation 2018b Classvent and classcool school ven-
tilation design tool. https://www.gov.uk/government/publications/
classvent-and-classcool-school-ventilation-design-tool.
Derraik, J., Anderson, W., Connelly, E. & Anderson, Y. 2020 Rapid evidence summary on
SARS-CoV-2 survivorship and disinfection, and a reusable ppe protocol using a double-hit process.
medRxiv .
DHSC 2020 Face coverings: when to wear one and how to make your own - gov.uk.
Dietz, L., Horve, P. F., Coil, D. A., Fretz, M., Eisen, J. A. & Van Den Wymelenberg, K.
2020 2019 Novel Coronavirus (COVID-19) Pandemic: Built Environment Considerations To Reduce
Transmission. mSystems 5 (2).
DoE 2020a Face coverings in education, https://www.gov.uk/government/publications/face-coverings-
in-education/face-coverings-in-education.

54
DoE 2020b www.gov.uk/government/publications/what-parents-and-carers-need-to-know-about-early-
years-providers-schools-and-colleges-during-the-coronavirus-covid-19-outbreak/what-parents-and-
carers-need-to-know-about-early-years-providers-schools-and-colleges.
Duan, S., Zhao, X., Wen, R., Huang, J., Pi, G., Zhang, S. & et al. 2003 Stability of SARS
coronavirus in human specimens and environment and its sensitivity to heating and UV irradiation.
Biomedical and environmental sciences 16, 246–255.
Dunn, G. J., Wilson, S. K., Duffy, B. R. & Sefiane, K. 2009 Evaporation of a thin droplet
on a thin substrate with a high thermal resistance. Physics of Fluids 21 (5), 052101, arXiv:
https://doi.org/10.1063/1.3121214.
Eames, I., Tang, J. W., Li, Y. & Wilson, P. 2009 Airborne transmission of disease in hospitals. J
R Soc Interface 6 (6), S697–S702.
Eickmann, M., Gravemann, U., Handke, W., Tolksdorf, F., Reichenberg, S., Muller, T.
& et al. 2020 Inactivation of three emerging viruses -severe acute respiratory syndrome coronavirus,
crimea-congo haemorrhagic fever virus and nipah virus -in platelet concentrates by ultraviolet c light
and in plasma by methylene blue plus visible light. Vox Sanguinis 115, 146–151.
Escombe, A. R., Moore, D. A. J., Gilman, R. H., Navincopa, M., Ticona, E., Mitchell, B.,
Noakes, C., Martı́nez, C., Sheen, P., Ramirez, R., Quino, W., Gonzalez, A., Friedland,
J. S. & Evans, C. A. 2009 Upper-room ultraviolet light and negative air ionization to prevent
tuberculosis transmission. PLOS Medicine 6 (3), 1–12.
Fennelly, K. P. 2020 Particle sizes of infectious aerosols: implications for infection control. The Lancet
Respiratory Medicine .
First, M., Nardell, E., Chaisson, W. & Riley, R. 1999a Guidelines for the application of upper-
room ultraviolet germicidal irradiation for preventing transmission of airborne contagion - Part I: Basic
principles. Transactions-American Society of Heating Refrigerating and Air Conditioning Engineers
105, 869–876.
First, M., Nardell, E., Chaisson, W. & Riley, R. 1999b Guidelines for the application of upper-
room ultraviolet irradiation for preventing transmission of airborne contagion: Part ii -design and
operation guidance. Transactions-American Society of Heating Refrigerating and Air Conditioning
Engineers 105, 1–10.
Gandhi, M., Beyrer, C. & Goosby, E. 2020 Masks do more than protect others during COVID-19:
Reducing the inoculum of SARS-CoV-2 to protect the wearer. Journal of general internal medicine
pp. 1–4.
Gilkeson, C. & Noakes, C. 2013 Application of CFD simulation to predicting upper-room uvgi
effectiveness. Photochemistry and photobiology 89, 799–810.
Glasbey, T. & Whiteley, G. 2020 Observations on disinfectant performance. Journal of Hospital
Infection 0 (0).
Government, H. 1992a The health and safety (display screen equipment) regulations 1992. https:
//www.legislation.gov.uk/uksi/1992/2792/contents/made.
Government, H. 1992b The workplace (health, safety and welfare) regulations 1992. https://www.
legislation.gov.uk/uksi/1992/3004/contents/made.
Government, H. 2013 Approved document f1 - means of ventilation.
Greenhalgh, T., Schmid, M. B., Czypionka, T., Bassler, D. & Gruer, L. 2020 Face masks for
the public during the COVID-19 crisis. Bmj 369.
Gregory, J. 2005 Particles in water: properties and processes. CRC Press.
Gregson, F. K. A., Watson, N. A., Orton, C. M., Haddrell, A. E., McCarthy, L. P., Finnie,
T. J., Gent, N., Donaldson, G. C., Shah, P. L., Calder, J. D., Bzdek, B. R., Costello, D.
& Reid, J. P. 2020 Comparing the respirable aerosol concentrations and particle size distributions
generated by singing, speaking and breathing. pre-print at chemrxiv.org .

55
Grifoni, D., Carreras, G., Sabatini, F. & Zipoli, G. 2005 Uv hazard on a summer’s day un-
der mediterranean conditions, and the protective role of a beach umbrella. International Journal of
Biometeorology 50 (2), 75–82.
Grote, H. & Izagaren, F. 2020 Covid-19: The communication needs of d/deaf healthcare workers
and patients are being forgotten. bmj 369.
Gupta, J. K., Lin, C. H. & Chen, Q. 2010 Characterizing exhaled airflow from breathing and talking.
Indoor air 20 (1), 31–39.
Hamzavi, I., Lyons, A., Kohli, I., Narla, S., Parks-Miller, A., Gelfand, J. & et al. 2020
Ultraviolet germicidal irradiation: possible method for respirator disinfection to facilitate reuse during
COVID-19 pandemic. Journal of the American Academy of Dermatology 82, 1511–1512.
Harm, W. 1980 Biological effects of ultraviolet radiation. Cambridge University Press.
Harrison, G. I. & Young, A. R. 2002 Ultraviolet radiation-induced erythema in human skin. Methods
28, 14–19.
Heimbuch, B. & Harnish, D. 2019 Research to mitigate a shortage of respiratory protection devices
during public health emergencies. contract no. hhsf223201400158c. Applied Research Associates .
Houk, V. 1980 Spread of tuberculosis via recirculated air in a naval vessel: the Byrd study. Annals of
the New York Academy of Sciences 353, 10–24.
HSE 2020 Air conditioning and ventilation during the coronavirus outbreak 2020. Health and
Safety Executive Https://www.hse.gov.uk/coronavirus/equipment-and-machinery/air-conditioning-
and-ventilation.htm.
Inagaki, H., Saito, A., Sugiyama, H., Okabayashi, T. & Fujimoto, S. 2020 Rapid inactivation
of SARS-CoV-2 with deep-UV LED irradiation. Emerging Microbes & Infections 9, 1744–1747.
Jagger, J. 1967 Introduction to research in ultraviolet photobiology. Prentice-Hall.
Jennison, M. W. 1941 Atomizing of mouth and nose secretions into the air as revealed by high-speed
photography. Aerobiology .
Jensen, M. 1964 Inactivation of airborne viruses by ultraviolet irradiation. Appl Environ Microbiol 12,
418–420.
Johnson, G. R., Morawska, L., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Chao, C.
Y. H., Wan, M. P., Li, Y., Xie, X., Katoshevski, D. & Corbett, S. 2011 Modality of human
expired aerosol size distributions. Journal of Aerosol Science 42 (12), 839–851.
Jones, B., Sharpe, P., Iddon, C., Hathway, E. A. & Fitzgerald, S. Pre-print Modelling uncer-
tainty in the relative risk of exposure to the sars-cov-2 virus by airborne aerosol transmission in well
mixed air in buildings.
Kampf, G., Todt, D., Pfaender, S. & Steinmann, E. 2020 Persistence of coronaviruses on inani-
mate surfaces and their inactivation with biocidal agents.
Kariwa, H., Fujii, N. & Takashima, I. 2006 Inactivation of SARS coronavirus by means of povidone-
iodine, physical conditions and chemical reagents. Dermatology 212(Suppl. 1), 119–123.
Keil, S., Ragan, I., Yonemura, S., Hartson, L., Dart, N. & Bowen, R. 2020 Inactivation of
severe acute respiratory syndrome coronavirus 2 in plasma and platelet products using a riboflavin
and ultraviolet light-based photochemical treatment. Vox Sanguinis .
Kerr, K., Beggs, C., Dean, S., Thornton, J., Donnelly, J., Todd, N., Sleigh, P., Qureshi,
A. & Taylor, C. 2005 Air ionisation and colonisation/infection with methicillin-resistant staphylo-
coccus aureus and acinetobacter species in an intensive care unit. Intensive care medicine 32, 315–317.
King, M., López-Garcı́a, M., Atedoghu, K., Zhang, N., Wilson, A., Weterings, M., Hiwar,
W., Dancer, S., Noakes, C. & Fletcher, L. 2020 Bacterial transfer to fingertips during sequential
surface contacts with and without gloves. Indoor Air Accepted.

56
Kinloch, A. J. 1987 Adhesion and Adhesives: Science and Technology. Chapman & Hall.
Kowalski, W. 2010 Ultraviolet germicidal irradiation handbook: UVGI for air and surface disinfection.
Springer science & business media.
Kowalski, W. & Bahnfleth, W. 2004 Proposed standards and guidelines for UVGI air disinfection.
IUVA News 6, 20–25.
Kowalski, W., Bahnfleth, W., Witham, D., Severin, B. & Whittam, T. 2000 Mathematical
modeling of ultraviolet germicidal irradiation for air disinfection. Quantitative microbiology 2, 249–270.
Kraay, A. N. M., Hayashi, M. A. L., Hernandez-Ceron, N., Spicknall, I. H., Eisenberg,
M. C., Meza, R. & Eisenberg, J. N. S. 2018 Fomite-mediated transmission as a sufficient pathway:
a comparative analysis across three viral pathogens. BMC infectious diseases 18 (1), 540.
Kukadia, V. & Upton, S. 2019 Ensuring good indoor air quality in buildings.
Kumar, P. & Morawska, L. 2019 Could fighting airborne transmission be the next line of defence
against covid-19 spread? City and environment interactions 4, 100033.
Kutter, J. S., Spronken, M. I., Fraaij, P. L., Fouchier, R. A. & Herfst, S. 2018 Transmission
routes of respiratory viruses among humans. Current Opinion in Virology 28, 142 – 151, emerging
viruses: intraspecies transmission * Viral Immunology.
Kähler, C. J. & Hain, R. 2020 Singing in choirs and making music with wind instruments
– is that safe during the sars-cov-2 pandemic? Universität München (non-peer reviewed report)
https://www.unibw.de/lrt7-en/making music during the sars-cov-2 pandemic.pdf.
Lai, K. M., Bottomley, C. & McNerney, R. 2011 Propagation of respiratory aerosols by the
vuvuzela. PLOS ONE 6 (5), e20086.
Leung, N. H., Chu, D. K., Shiu, E. Y., Chan, K. H., McDevitt, J. J., Hau, B. J., Yen, H. L.,
Li, Y., Ip, D. K., Peiris, J. S., Seto, W. H., Leung, G. M., Milton, D. K. & Cowling,
B. J. 2020a Respiratory virus shedding in exhaled breath and efficacy of face masks. Nature Medicine
26 (5), 676–680.
Leung, N. H. L., Chu, D. K. W., Shiu, E. Y. C., Chan, K. H., McDevitt, J. J., Hau, B. J. P.,
Yen, H. L., Li, Y., Ip, D. K. M., Peiris, J. S. M. & others 2020b Respiratory virus shedding
in exhaled breath and efficacy of face masks. Nat. Med. pp. 1–5.
Lindsley, W. G., Noti, J. D., Blachere, F. M., Szalajda, J. V. & Beezhold, D. H. 2014
Efficacy of face shields against cough aerosol droplets from a cough simulator. Journal of Occupational
and Environmental Hygiene 11 (8), 509–518.
Liu, L., Wei, J., Li, Y. & Ooi, A. 2017 Evaporation and dispersion of respiratory droplets from
coughing. Indoor Air 27 (1), 179–190.
Liu, Z. & Sun, C.-b. 2020 Conjunctiva is not a preferred gateway of entry for SARS-CoV-2 to infect
respiratory tract. Journal of Medical Virology .
Mamane, H. 2008 Impact of particles on UV disinfection of water and wastewater effluents: a review.
Reviews in Chemical Engineering 24, 67–157.
Mandelbrot, B. B. 2006 Fractal analysis and synthesis of fracture surface roughness and related forms
of complexity and disorder. Int J Fracture 138, 13–17.
Mandelbrot, B. B., Passoja, D. E. & Paullay, A. J. 1984 Fractal character of fracture surfaces
of metals. Nature 308, 721–722.
Marr, L. C., Tang, J. W., J., V. M. & Lakdawala, S. S. 2019 Mechanistic insights into the
effect of humidity on airborne influenza virus survival, transmission and incidence. J. R. Soc. Interface
16 (150), 20180298.
Matheson, N. J. & Lehner, P. J. 2020 How does SARS-CoV-2 cause COVID-19? Science 369 (6503),
510–511.

57
McDevitt, J., Lai, K., Rudnick, S., Houseman, E., First, M. & Milton, D. 2007 Characteri-
zation of uvc light sensitivity of vaccinia virus. Appl Environ Microbiol 73, 5760–5766.
McDevitt, J., Milton, D., Rudnick, S. & First, M. 2008 Inactivation of poxviruses by upper-room
UVC light in a simulated hospital room environment. PLoS One 3, e3186.
McDevitt, J., Rudnick, S. & Radonovich, L. 2012 Aerosol susceptibility of influenza virus to uv-c
light. Appl. Environ. Microbiol. 78, 1666–1669.
McLean, R. 1961 The mechanism of spread of Asian influenza: general discussion. Am. Rev. Respir.
Dis. 83, 36–38.
Melikov, A. 2004 Personalized ventilation. Indoor Air 14 (s7), 157–167, arXiv:
https://onlinelibrary.wiley.com/doi/pdf/10.1111/j.1600-0668.2004.00284.x.
Melikov, A. K., Ai, Z. T. & Markov, D. 2020 Intermittent occupancy combined with ventilation:
An efficient strategy for the reduction of airborne transmission indoors. Sci. Total Environ. p. 140908.
Melikov, A. K., Cermak, R. & Majer, M. 2002 Personalized ventilation: evaluation of different air
terminal devices. Energy and Buildings 34 (8), 829 – 836, rEHVA Scientific.
Miller, S., Xu, P., Peccia, J., Fabian, P. & Hernandez, M. 1999 Effects of ultravioletgermicidal
irradiation of room air on airborne bacteria and mycobacteria. Indoor Air, Proc of 8th International
Conference on Indoor Air Quality and Climate 2, 665–670.
Milton, D. K. 2020 A Rosetta Stone for Understanding Infectious Drops and Aerosols. Journal of the
Pediatric Infectious Diseases Society .
Mingotti, N., Wood, R., Noakes, C. J. & Woods, A. W. In press The mixing of airborne
contaminants by the repeated passage of people along a corridor. J. Fluid Mech. .
Mingotti, N. & Woods, A. In prep. The impact of people-driven mixing on the ventilation of airborne
aerosols from a corridor. J. Fluid Mech. .
Mingotti, N. & Woods, A. W. 2015a On the transport of heavy particles through a downward
displacement-ventilated space. J. Fluid Mech. 774, 192–223.
Mingotti, N. & Woods, A. W. 2015b On the transport of heavy particles through an upward
displacement-ventilated space. J. Fluid Mech. 772, 478–507.
Mittal, R., Ni, R. & Seo, J. H. 2020 The flow physics of COVID-19. J. Fluid Mech. 894, F2.
Mitze, T., Kosfeld, R., Rode, J. & Wälde, K. 2020 Face masks considerably reduce COVID-19
cases in germany: A synthetic control method approach. IZA Discussion Paper .
Morawska, L. & Milton, D. K. 2020 It is time to address airborne transmission of COVID-19. Clin.
Infect. Dis. 6, ciaa939.
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G.,
Cao, J., Dancer, S., Floto, A., Franchimon, F. & others 2020 How can airborne transmission
of COVID-19 indoors be minimised? Environment International p. 105832.
Mosley, R., Greenwell, D., Sparks, L., Guo, Z., Tucker, W., Fortmann, R. & Whitfield,
C. 2001 Penetration of ambient fine particles into the indoor environment. Aerosol Science & Tech-
nology 34 (1), 127–136.
Musicians’ Union 2020 Coronavirus (covid-19) advice. Musicians’ Union Website
https://www.musiciansunion.org.uk/coronavirus.
Nardell, E. & R., N. 2019 Air disinfection in measles transmission hotspots. The Lancet 394, 1009–
1010.
Nardell, E. A., Bucher, S. J., Brickner, P. W., Wang, C., Vincent, R. L., Becan-McBride,
K., James, M. A., Michael, M. & Wright, J. D. 2008 Safety of upper-room ultraviolet germicidal
air disinfection for room occupants: results from the tuberculosis ultraviolet shelter study. Public Health
Rep 123 (1), 52–60.

58
Nicas, M. & Best, D. 2008 A study quantifying the hand-to-face contact rate and its potential appli-
cation to predicting respiratory tract infection. Journal of Occupational and Environmental Hygiene
5 (6), 347–352, pMID: 18357546, arXiv: https://doi.org/10.1080/15459620802003896.
Nicas, M. & Miller, S. 1999 A multi-zone model evaluation of the efficacy of upper-room air ultraviolet
germicidal irradiation. Applied Occupational and Environmental Hygiene 14, 317–328.
Nicas, M., Nazaroff, W. & Hubbard, A. 2005 Toward understanding the risk of secondary airborne
infection: emission of respirable pathogens. Journal of Occupational and Environmental Hygiene 2,
143–154.
Noakes, C., Beggs, C. & Sleigh, P. 2004a Modelling the performance of upper room ultraviolet
germicidal irradiation devices in ventilated rooms: comparison of analytical and CFD methods. Indoor
and Built Environment 13, 477–488.
Noakes, C., Beggs, C. & Sleigh, P. 2004b Numerical investigation of upper-room uvgi disinfection
efficacy in an environmental chamber with a ceiling fan. Proceedings of ASHRAE IAQ 2004 pp. 1–13.
Noakes, C., Sleigh, P., Escombe, A. & Beggs, C. 2006 Use of CFD analysis in modifying a TB
ward in Lima, Peru. Indoor and Built Environment 15, 41–47.
Noakes, C. J., Khan, M. A. I. & Gilkeson, C. A. 2015 Modeling infection risk
and energy use of upper-room ultraviolet germicidal irradiation systems in multi-room en-
vironments. Science and Technology for the Built Environment 21 (1), 99–111, arXiv:
https://doi.org/10.1080/10789669.2014.983035.
Ollila, H. M., Partinen, M., Koskela, J., Savolainen, R., Rotkirch, A. & Laine, L. T. 2020
Face masks prevent transmission of respiratory diseases: a meta-analysis of randomized controlled
trials. medRxiv .
Orchester.ch 2020 Schutzkonzept im rahmen der schrittweisen lockerung der bag-massnahmen
zum schutz der bevölkerung vor dem coronavirus (covid-19) für theater-, konzert- und ve-
ranstaltungsbetriebe in der schweiz, version 2.2. Schweizer Verband Technishcher Bühnen-
und Veranstaltungsberufe https://www.svtb-astt.ch/wp-content/uploads/2020/05/200522-
Schutzkonzept COVID-19 Theater Konzert Veranstaltung V2 2.pdf, 22 May.
Performing Arts Aerosol Study 2020 Round one preliminary results: Clarinet, flute,
horn, soprano singer, trumpet. National Federation of State High School Associations
https://www.nfhs.org/media/4029952/preliminary-testing-report-7-13-20.pdf.
Prather, K. A., Wang, C. C. & Schooley, R. T. 2020 Reducing transmission of SARS-CoV-2.
Science .
Ragan, I., Hartson, L., Pidcoke, H., Bowen, R. & Goodrich, R. 2020 Pathogen reduction of
SARS-CoV-2 virus in plasma and whole blood using riboflavin and UV light. PLoS One 15, e0233947.
Redrow, J., Mao, S., Celik, I., Posada, J. A. & Feng, Z. G. 2011 Modeling the evaporation
and dispersion of airborne sputum droplets expelled from a human cough. Build. Environ. 46 (10),
2042–2051.
Reed, N. 2010 The history of ultraviolet germicidal irradiation for air disinfection. Public health reports
125, 15–27.
REHVA 2020 How to operate HVAC and other building service systems to prevent the spread of the
coronavirus (SARS-CoV-2) disease (COVID-19) in workplaces. REHVA COVID-19 guidance document
.
Ren, S. Y., Wang, W. B., Hao, Y. G., Zhang, H. R., Wang, Z. C., Chen, Y. L. & Gao, R. D.
2020 Stability and infectivity of coronaviruses in inanimate environments.
Riley, E. C., Murphy, G. & Riley, R. L. 1978 Airborne spread of measles in a suburban elementary
school. American journal of epidemiology 107 (5), 421–432.
Rudnick, S. N. & Milton, D. K. 2003 Risk of indoor airborne infection transmission estimated from
carbon dioxide concentration. Indoor Air 13, 237–245.

59
Rusin, P., Maxwell, S. & Gerba, C. 2002 Comparative surface-to-hand and fingertip-to-mouth
transfer efficiency of gram-positive bacteria, gram-negative bacteria, and phage. Journal of Applied
Microbiology 93 (4), 585–92.
Sagripanti, J. & Lytle, C. 2020 Estimated inactivation of coronaviruses by solar radiation with
special reference to COVID-19. Photochemistry and Photobiology 96, 731–737.
Schuit, M., Ratnesar-Shumate, S., Yolitz, J., Williams, G., Weaver, W., Green,
B., Miller, D., Krause, M., Beck, K., Wood, S., Holland, B., Bohannon, J.,
Freeburger, D., Hooper, I., Biryukov, J., Altamura, L. A., Wahl, V., Hevey,
M. & Dabisch, P. 2020 Airborne SARS-CoV-2 is Rapidly Inactivated by Simulated Sun-
light. The Journal of Infectious Diseases eprint: https://academic.oup.com/jid/advance-article-
pdf/doi/10.1093/infdis/jiaa334/33379426/jiaa334.pdf.
Scottish Government 2020a Coronavirus (COVID-19): guidance for universities - gov.scot.
Scottish Government 2020b Face coverings in schools.

Siegel, J. A. 2016 Primary and secondary consequences of indoor air cleaners. Indoor Air 26 (1),
88–96, arXiv: https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12194.
Signify 2020 Signify and boston university validate effectiveness of signify’s uv-c light sources on
inactivating the virus that causes COVID-19 2020. Signify Https://www.signify.com/en-gb/our-
company/news/press-releases/2020/20200616-signify-boston-university-validate-effectiveness-signify-
uvc-light-sources-on-inactivating-virus-that-causes-covid19.
Sloan Brittain, O., Wood, H. & Kumar, P. 2020 Prioritising indoor air quality in building design
can mitigate future airborne viral outbreaks. Cities & Health pp. 1–4.
Stadnytskyi, V., Bax, C. E., Bax, A. & Anfinrud, P. 2020 The airborne lifetime of small speech
droplets and their potential importance in SARS-CoV-2 transmission. Proc. Natl. Acad. Sci. 117 (22),
11875–11877.
Stelzer-Braid, S., Oliver, B. G., Blazey, A. J., Argent, E., Newsome, T. P., Rawlinson,
W. D. & Tovey, E. R. 2009 Exhalation of respiratory viruses by breathing, coughing, and talking.
J. med. virol. 81 (9), 1674–1679.

Stutt, R. O., Retkute, R., Bradley, M., Gilligan, C. A. & Colvin, J. 2020 A modelling
framework to assess the likely effectiveness of facemasks in combination with “lock-down” in managing
the COVID-19 pandemic. Proceedings of the Royal Society A 476 (2238), 20200376.
Thatcher, T. L., Lai, A. C., Moreno-Jackson, R., Sextro, R. G. & Nazaroff, W. W.
2002 Effects of room furnishings and air speed on particle deposition rates indoors. Atmospheric
Environment 36 (11), 1811 – 1819.
The Royal Society 2020a Face masks and coverings for the general public: Behavioural knowledge,
effectiveness of cloth coverings and public messaging.
The Royal Society 2020b Face Masks for the General Public — Royal Society DELVE Initiative.

The Vienna Philharmonic 2020 Philharmoniker zeigen geringe infektionsgefahr auf. Wein ORF.at
https://wien.orf.at/stories/3049099, 17 May.
Turner, J. S. 1973 Buoyancy Effects in Fluids. Cambridge University Press.
UK Government 2020 The R number and growth rate in the uk.

US EPA, O. 2020 List N: Disinfectants for Use Against SARS-CoV-2.


van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A.,
Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., Lloyd-
Smith, J. O., De Wit, E. & Munster, V. J. 2020 Aerosol and surface stability of SARS-CoV-2
as compared with SARS-CoV-1. New England Journal of Medicine 382 (16), 1564–1567.

60
Vasickova, P., Pavlik, I., Verani, M. & Carducci, A. 2010 Issues concerning survival of viruses
on surfaces.
Verma, S., Dhanak, M. & Frankenfield, J. 2020 Visualizing droplet dispersal for face shields and
masks with exhalation valves. Physics of Fluids 32 (9), 91701.

Volckens, J., Goble, D., Phillips, R., Henry, C. & Pidcoke, H. 2020 Reducing
bioaerosol emissions and exposures in the performing arts: A scientific roadmap for a safe
return from covid19. Colorado State University white paper https://smtd.colostate.edu/wp-
content/uploads/sites/34/2020/05/CSU-Performing-Arts-Aerosol-Study-v3.pdf.

Vouriot, C., Burridge, H. C., King, M.-F., Noakes, C. J. & Linden, P. F. In Preparation The
seasonal variation in airborne infection risk from monitored CO2 — COVID-19 as a case-study. Indoor
Air .
Walker, C. & Ko, G. 2007 Effect of ultraviolet germicidal irradiation on viral aerosols. Environmental
Science & Technology 41, 5460–5465.

Warnes, S. L., Little, Z. R. & Keevil, C. W. 2015 Human coronavirus 229E remains infectious
on common touch surface materials. mBio 6 (6).
Wells, W. F. 1934 On air-borne infection study II. Droplets and droplet nuclei. American Journal of
Epidemiology 20 (3), 611–618, publisher: Oxford Academic.

Wells, W. F. 1955 Airborne Contagion and Air Hygiene. An Ecological Study of Droplet Infections..
Cambridge, MA, Harvard University Press.
WHO 2014 Infection prevention and control of epidemic-and pandemic-prone acute respiratory infections
in health care. World Health Organization.
WHO 2020 Advice on the use of masks in the community, during home care, and in health care settings
in the context of COVID-19: interim guidance, 19 march 2020. Tech. Rep.. World Health Organization.
WHO 2020 Q&A: Ventilation and air conditioning in public spaces and buildings and COVID-19:
World health organization. World Health Organisation Https://www.who.int/news-room/q-a-detail/q-
a-ventilation-and-air-conditioning-in-public-spaces-and-buildings-and-covid-19.

de Wijk, R. A., Maaskant, A. M., Kremer, S., Holthuysen, N. T. E. & Stijnen, D. A. J. M.


2018 Supermarket shopper movements versus sales and the effects of scent, light, and sound. Food
Quality and Preference 70, 32–39.
Wilson, A. M., Abney, S. E., King, M.-F., Weir, M. H., López-Garcı́a, M., Sexton, J. D.,
Dancer, S. J., Proctor, J., Noakes, C. J. & Reynolds, K. A. 2020a COVID-19 and non-
traditional mask use: How do various materials compare in reducing the infection risk for mask
wearers? The Journal of Hospital Infection .
Wilson, A. M., Verhougstraete, M. P., Beamer, P. I., King, M.-F., Reynolds, K. A. &
Gerba, C. P. 2020b Frequency of hand-to-head, -mouth, -eyes, and -nose contacts for adults and
children during eating and non-eating macro-activities. Journal of exposure science & environmental
epidemiology Accepted.
Wölfel, R., Corman, V. M., Guggemos, W., Seilmaier, M., Zange, S., Müller, M. A.,
Niemeyer, D., Jones, T. C., Vollmar, P., Rothe, C. & others 2020 Virological assessment of
hospitalized patients with COVID-2019. Nature 581 (7809), 465–469.
Woods, A. W., Dello Ioio, G. & Mingotti, N. Under review On the fate of airborne aerosols in
buildings. Indoor Air .
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L. & Seto, W. 2007 How far droplets can move
in indoor environments – revisiting the wells evaporation–falling curve. Indoor Air 17 (3), 211–225,
arXiv: https://doi.org/10.1111/j.1600-0668.2007.00469.x.

Xie, X., Li, Y., Sun, H. & Liu, L. 2009 Exhaled droplets due to talking and coughing. J. R. Soc.
Interface 6 (suppl 6), S703–S714.

61
Xu, M., Nematollahi, M., Sextro, R. G., Gadgil, A. J. & Nazaroff, W. W. 1994 Deposition
of tobacco smoke particles in a low ventilation room. Aerosol Science and Technology 20 (2), 194–206,
arXiv: https://doi.org/10.1080/02786829408959676.
Xu, P., Qian, H., Miao, T., Yen, H., Tan, H., Cowling, B. & et al. 2020 Transmission routes
of COVID-19 virus in the Diamond Princess Cruise ship. medRxiv .
Yan, J., Grantham, M., Pantelic, J., De M., P. J. B., Albert, B., Liu, F., Ehrman, S.,
Milton, D. K., Consortium, E. & others 2018 Infectious virus in exhaled breath of symptomatic
seasonal influenza cases from a college community. Proc. Natl. Acad. Sci. 115 (5), 1081–1086.

Yang, S., Lee, G. W., Chen, C.-M., Wu, C.-C. & Yu, K.-P. 2007 The size and concentration of
droplets generated by coughing in human subjects. Journal of Aerosol Medicine 20 (4), 484–494.
Yang, Y., Lai, A., Kong, R. & Deng, Q. 2017 Experimental and numerical study of the performance
of upper-room ultraviolet germicidal irradiation with the effective Z-value of airborne bacteria. Aerosol
Science and Technology 51, 1123–1134.

Yang, Y., Zhang, H., Nunayon, S., Chan, V. & Lai, A. 2018 Disinfection efficacy of ultraviolet
germicidal irradiation on airborne bacteria in ventilation ducts. Indoor Air 28, 806–817.
Yap, T. F., Liu, Z., Shveda, R. A. & Preston, D. 2020 A Predictive Model of the Temperature-
Dependent Inactivation of Coronaviruses. Applied Physics Letters 117.

Ye, G., Lin, H., Chen, L., Wang, S., Zeng, Z., Wang, W., Zhang, S., Rebmann, T., Li, Y., Pan,
Z., Yang, Z., Wang, Y., Wang, F., Qian, Z. & Wang, X. 2020 Environmental contamination of
the SARS-CoV-2 in healthcare premises: An urgent call for protection for healthcare workers. medRxiv
p. 2020.03.11.20034546.
Zaffina, S., Camisa, V., Lembo, M., Vinci, M. R., Tucci, M. G., Borra, M., Napolitano, A.
& Cannatà, V. 2012 Accidental exposure to uv radiation produced by germicidal lamp: case report
and risk assessment. Photochem Photobiol 88 (4), 1001–1004.
Zhang, N. & Li, Y. 2018 Transmission of influenza a in a student office based on realistic person-
to-person contact and surface touch behaviour. International Journal of Environmental Research and
Public Health 15 (8), 1699.

Zhang, N., Li, Y. & Huang, H. 2018 Surface touch and its network growth in a graduate student
office. Indoor Air 28 (6), 963–972, arXiv: https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12505.
Zhang, R., Li, Y., Zhang, A. L., Wang, Y. & Molina, M. J. 2020 Identifying airborne transmission
as the dominant route for the spread of COVID-19. Proc. Natl. Acad. Sci. 117 (26), 14857–14863.

Zhu, S., Srebric, J., Rudnick, S., Vincent, R. & Nardell, E. 2013 Numerical investigation of
upper-room uvgi disinfection efficacy in an environmental chamber with a ceiling fan. Photochemistry
and photobiology 89, 782–791.
Zuraimi, M., Nilsson, G. & Magee, R. 2011 Removing indoor particles using portable air cleaners:
Implications for residential infection transmission. Building and Environment 46 (12), 2512 – 2519.

62

You might also like