0% found this document useful (0 votes)
26 views1 page

Weir Lighting Boq

The document discusses the bill of quantities for electrical items needed for weir illumination at Kurmitar Iron Ore Mines. It includes items like panels, low voltage cables, cable end termination and connections, and steel tubular poles with LED lighting fixtures.

Uploaded by

HRP Infra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views1 page

Weir Lighting Boq

The document discusses the bill of quantities for electrical items needed for weir illumination at Kurmitar Iron Ore Mines. It includes items like panels, low voltage cables, cable end termination and connections, and steel tubular poles with LED lighting fixtures.

Uploaded by

HRP Infra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : DESIGN AND ENGINEERING OF CHECK DAM, GABION CHECK DAMS, AND INTAKE WELL AND WATER SUPPLY

18-05-2024
SYSTEM FOR KURMITAR IRON ORE MINES.
DOCUMENT : BILL OF QUANTITY FOR ELECTRICAL ITEMS FOR WEIR ILLUMINATION
Sr No Description SUPPLY INSTALLATION
RATE RATE
TOTAL
PER PER TOTAL RATE
Unit Qty. RATE
UNIT UNIT (Rs.)
(Rs.)
(Rs.) (Rs.)
PANEL
Installation, assembling, connection, testing and commissioning of Panels including
distribution of power to all required equipment at 415 Volts including protections. LT
Switchgear shall be Non - draw out type, Single Front, Form , bottom cable entry, 50kA
1
for 1 sec, CRCA enclosure (load bearing 2mm, non-load bearing 1.6mm, removable
gland plate 3mm), bus bars of Aluminum Alloy @ 0.8A/mm2 current density or copper.
Feeders rated 630A and below will be provided with MCCB . All the component of MCC
shall be of Siemens, L&T, ABB. panel Degree of protection shall be IP55.
Incomer:-63A,4P MCCB,1No
Outgoing:-16 A ,3P MCB,4 Nos
1 15000 15000 1500 1500
LOW VOLTAGE CABLE
2 DOCUMENT NUMBER: 1261‐OHP‐GEN‐EE‐DOC‐002(VD Calculation & Cable
Schedule) & 1261-OHP-GEN-EE-002(Cable layout)
Supply Installation testing & Commissioning of LV Power Cables:
Conductor: Stranded Electrolytic grade Annealed bare copper/ Aluminium
conductor of H4 grade as per Class 2 of IS : 8130/1984 / Copper conductor,
A2xFY / A2xWY
Insulation: Extruded XLPE as per IS: 7098 P-1/ 1988
Inner Sheath: Extruded PVC " Type ST-2 " as per IS: 5831
Armour: Galvanised Steel Flat strip as per IS: 3975
Outer Sheath: Extruded FRLSH PVC " Type ST-2 " as per IS: 5831 with Anti
rodent and termite properties

The scope shall include:


Unloading at site store.
Shifting of cable from site store to place of installation.
Excavation in hard or soft murrem / rocky area upto required depth, supply and
laying of protection bricks, supply and backfilling with fine sand, leveling the
ground to match with the existing condition.
Laying of cable in the excavated trench / prepared trench / cable tray / duct /
hume pipe / channel / floor trunks when laid inside or outside the building.

Connection of cable.
Supply & fixing of cable clamps, brackets, supports, route markers etc. where
ever required to fix the cables safely.
Earthing the glands and armouring with earthing clamp and jumper and also
connecting to common earth bar.
Testing of insulation and continuity of cable and submission of reports to the
client's representative.
4C X 2.5 SQ. MM. CU XLPE(LAYING IN CABLE TRAY) RMT. 100 359 35900 40 4000
3 CABLE END TERMINATION AND CONNECTION

Supply, fixing, connection, testing & commissioning of single/double


compression brass cable glands and crimping type Bimetalic lugs / sockets with
necessary tools and equipments as specified in specifications and IS. For
outdoor installations, nickel plated, cone grip type, double compression glands
shall be considered. The glands and lugs / sockets shall be suitable for cable
size and type mentioned above. The job also includes, if necessary, supply and
fixing of extension busbar of same material on circuit breaker or panel board
terminal / connector to connect more than one no. of parallel cables or to
connect higher size cable to lower size unit. The job also includes earthing the
glands and armour of the cable with common earth bar or flexible copper mesh.

4C X 2.5 SQ. MM. CU XLPE(LAYING IN CABLE TRAY) Nos 2 120 240 350 700

Supply, Installation, testing and commissioning of steel tubular poles of 3000


mm height made of 40mm dia GI pipe,25W LED IP 66 rated well-glass lighting
fixture, junction box, stud type terminal block for loop in/loop out as per
technical specification, drawing and relavent IS.
4 Scope shall also cover supply, installation, testing and commissioning of Well Nos 2 12500 25000 1600 3200
glass 1x 25W, LED, Light Fixture equivalent to: PHILIPS BGP281 T25
Make of Light fixtures shall be either Phillips/ Bajaj/ Crompton/ C&S/ Havells.

76140 9400