Return Filters
E 210 · E 211 · E 221
· Tank top mounting
· Connection up to G1¼
· Nominal flow rate up to 210 l/min
20.40-4e
Description
Application Filter elements
In the return line circuits of hydraulic systems. Flow direction from outside to centre. The star-shaped pleating of the filter
material results in:
Performance features • large filter surfaces
Protection • low pressure drop
against wear: By means of filter elements that, in full-flow filtration, • high dirt-holding capacities
meet even the highest demands regarding cleanliness • long service life
classes.
Protection against Filter maintenance
malfunction: By means of full-flow filtration in the system return, the By using a clogging indicator the correct moment for maintenance is stated
pumps above all are protected from dirt particles and guarantees the optimum utilization of the filter life.
remaining in the system after assembly, repairs, or
which are generated by wear or enter the system from Materials
outside. Screw-on cap: Polyester, GF reinforced
Filter head: Aluminium alloy
Special features Filter bowl: Steel
By-pass valve: The location close to the inlet port prevents dirt Seals: NBR (Viton on request)
particles retained by the filter element from entering Filter media: EXAPOR®MAX - inorganic multi-layer microfibre web
into the clear oil side. Paper - cellulose web, impregnated with resin
Removable bowl: In case of maintenance the filter bowl is removed
together with the filter element - therefore dirt particles Accessories
are not flushed back into the tank. Electrical and optical clogging indicators are available.
Dimensions and technical data see catalogue sheet 60.20.
Characteristics
Nominal flow rate Hydraulic fluids
Up to 210 l/min (see Selection Chart, column 2) Mineral oil and biodegradable fluids
The nominal flow rates indicated by ARGO-HYTOS are based on the (HEES or HETG, see info-sheet 00.20)
following features:
• closed by-pass valve at ν ≤ 200 mm2/s Temperature range
• element service life > 1000 operating hours at an average - 30 °C ... + 100 °C (temporary - 40 °C ... + 120 °C)
fluid contamination of 0,07 g per l/min flow volume
• flow velocity in the connection lines ≤ 4,5 m/s Viscosity at nominal flow rate
• at operating temperature: ν < 60 mm2/s
Connection • as starting viscosity: νmax = 1200 mm2/s
Threaded ports according to ISO 228 or DIN 13. Sizes see Selection Chart, • at first operation: The recommanded starting viscosity can be
column 6 (other port threads on request) read from the Diagram D (pressure drop as
a function of the kinematic viscosity) as
Filter fineness follows: Find the 70% ∆p of the cracking
5 µm(c) ... 30 µm(c) pressure of the by-pass valve on the vertical
β-values according to ISO 16889 axis. Draw a horizontal line so that it inter-
(see Selection Chart, column 4 and Diagram Dx) sects the ∆p curve at a point. Read this point
on the horizontal axis for the viscosity.
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889 Operating pressure
(see Selection Chart, column 5) Max. 10 bar
Mounting position
Preferably vertical, outlet downwards
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
D1 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0=casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
D2 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0=casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
D3 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0=casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
Filter fineness curves in Selection Chart, column 4
Dx Filtration ratio β as a function of particle size x obtained by the
Multi-Pass-Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR® MAX- and Paper elements:
5 E-X = β5 (c) = 200 EXAPOR®MAX
8 E-X = β8 (c) = 200 EXAPOR®MAX
Filtration ratio β for particles > x µm
12 E-X = β12 (c) = 200 EXAPOR®MAX
Efficiency [%]
16 E-X = β16 (c) = 200 EXAPOR®MAX
30 P = β30 (c) = 200 Paper
Based on the structure of the filter media of the 30 P paper
elements, deviations from the printed curves are quite probable.
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Particle size x [µm] (for particles larger
than the given particle size x)
Selection Chart
Dx ss nt
r. pa
. iag fb
y- leme
no D city o re
ee
p s /curv
e see cap
a
ssu
re filt
e
o w r o e ss g n A r e e nt
n
No
. na
l fl re d m D ne ldin ctio gp l cem o. rks
t mi ressu iagra e rfi t - ho n ne c kin bo pla rt N ig ht ma
Par N o P D Fi l t Di r C o Cra Sym Re Pa We Re
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11
E 210-59 60 D1/1 5 E-X 25 G1 2,5 1 V2.0920-03 2,3 -
E 210-66 130 D1/2 12 E-X 40 G1 2,5 1 V2.0920-06 2,3 -
E 210-58 180 D1/3 16 E-X 47 G1¼ 2,5 1 V2.0920-08 2,3 -
E 210-51 120 D1/4 30 P 22 G1¼ 1,5 1 P2.0920-11* 2,3 -
E 211-59 110 D2/1 5 E-X 50 G1 2,5 1 2 x V2.0920-03 3,4 -
E 211-56 210 D2/2 12 E-X 80 G1¼ 2,5 1 2 x V2.0920-06 3,4 -
E 211-58 210 D2/3 16 E-X 94 G1¼ 2,5 1 2 x V2.0920-08 3,4 -
E 211-51 210 D2/4 30 P 44 G1¼ 1,5 1 2 x P2.0920-11* 3,4 -
E 221-59 100 D3/1 5 E-X 36 G1 2,5 1 V2.0833-03 3,3 -
E 221-56 210 D3/2 12 E-X 58 G1¼ 2,5 1 V2.0833-06 3,3 -
E 221-58 210 D3/3 16 E-X 67 G1¼ 2,5 1 V2.0833-08 3,3 -
E 221-51 210 D3/4 30 P 36 G1¼ 1,5 1 P2.0833-01* 3,3 -
All filters are delivered with a plugged clogging indicator connection M 12 x 1,5. As clogging indicators either manometers or electrical pressure
switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below
mentioned codes.
Order example: The filter E 210-66 has to be supplied with an extension pipe (EV) for a mounting depth of 300 mm.
Order description: E 210-66 / EV 300
Part No. (Basic unit)
Extension pipe (4 various lengths are available)
E 210 / E 211: EV = K + 95 / + 195 / + 295 / + 395
E 221: EV = K + 139 / + 239 / + 339 / + 439
(see dimensions and measurements)
For the appropriate clogging indicators see catalogue sheet 60.20.
Remarks:
• The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the
by-pass valve (see Selection Chart, column 7).
• The clogging indicators are optionally available and will then be loosely provided.
• The filters listed in this chart are standard filters. Other designs available on request.
* Paper media supported with metal gauze
Dimensions
Groove for O-Ring 126 x 4
O-Ring Part No. N007.1264
on request
Dia hole in
reservoir
Design with 2 inlet ports on request Design with 1 inlet port Required mounting surface
Connection M12 x 1,5 Connection M12 x 1,5
for clogging indicator for clogging indicator
Measurements
Type A B C D E F G H I K L M N O P Q R
min./max.
E 210 G1, G1¼ 126,5 111/121 95,5 110 11,5 32 106 325 205 165 141 76 11 13 35 -
E 211 G1, G1¼ 126,5 111/121 95,5 110 11,5 32 106 525 405 165 141 76 11 13 35 -
E 221 G1, G1¼ 126,5 111/121 95,5 110 11,5 32 106 465 361 165 141 76 11 13 35 15
Symbols
1 2 3 4
Spare Parts
1 1 Pos. Designation Part No.
1 Screw-on cap with Pos. 5 ES 074.1212
4a 2a 2 4 2 Magnetic system D 020.1401
3a 3 2a Hollow rivet A 8 x 0,75 x 25 3309059
DIN 7340-St
5
3 Cylinder screw assy E 210.1201
6 3a Cylinder screw M6x35 3302006
DIN 912-8.8
4 Screw-on cap assy with Pos. 5 E 210.1210
4a Screw-on cap assy with Pos. 5 E 210.1200
5 O-ring 100 x 4 N 007.1004
6 By-pass E 210/E 211 (1,5 bar) E 210.1903
7 6 By-pass E 210/E 211 (2,5 bar) E 210.1905
6 By-pass E 221 (1,5 bar) E 221.1903
6 By-pass E 221 (2,5 bar) E 210.1905
7 Filter element see Chart / col. 9
8 Filter bowl E 210 * E 210.1901
8 Filter bowl E 211 * E 211.1901
8 Filter bowl E 221 * E 221.1901
9 O-ring 90 x 4 N 007.0904
8 10 O-ring 126 x 4 ** N 007.1264
1
Specify mounting depth in mm
2
Not included in basic equipment
9 The functions of the complete filters as well as the outstanding features
of the filter elements assured by ARGO-HYTOS can only be guaranteed if
original ARGO-HYTOS spare parts are used.
10
Quality Assurance
Quality management according to DIN EN ISO 9001 ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 3968 Evaluation of pressure drop versus flow characteristics
To ensure constant quality in production and operation, ISO 16889 Multi-Pass-Test (evaluation of filter fineness and
ARGO-HYTOS filter elements undergo strict controls and tests dirt-holding capacity)
according to the following DIN and ISO standards:
Various quality controls during the production process guarantee the
DIN ISO 2941 Verification of collapse/burst resistance leakfree function and solidity of our filters.
DIN ISO 2943 Verification of material compatibility with fluids
DIN ISO 3724 Verification of flow fatigue characteristics
Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
We produce fluid power solutions
ARGO-HYTOS GMBH · Industriestraße 9 · D-76703 Kraichtal
Tel: +49 7250 76-0 · Fax: +49 7250 76-199 · info.de@argo-hytos.com · www.argo-hytos.com
Subject to change · 9107167-e · 0905