Mitsubishi HS-X Gas Insulated Switchgear
Mitsubishi HS-X Gas Insulated Switchgear
MODEL
HS-X (TYPE1)
12kV/24kV
                       Advanced environmentally
                       friendly switchgear
             Advanced environmentally friendly s
              Mitsubishi Electric Corporation has designed and manufactured a substantial amount of
              high quality switchgear all over the world. This vast experience was drawn on to produce
              the next generation of advanced environmentally friendly switchgear, the ”HS-X”.
01   MITSUBISHI HS-X
y switchgear
C O NT E NT S
RATINGS 03
FEATURES 04
COMPONENTS 05
SWITCHGEAR ARRANGEMENT 11
FOUNDATION DRAWING 13
    E
                                                                                                                  STANDARD & OPTIONAL SPECIFICATIONS                                  13
-
          nvironmentally friendly - SF6 Free                                                                      STANDARD ACCESSORIES                                                14
y
l         Mitsubishi Electric Co. is the world leader in establishing compressed
          dry air insulation technology based on the design and development                                       OPTION                                                              14
          technologies of conventional SF6 switchgear. Under dry, clean and
          compression, air has good insulation properties, which makes it
          ideally suitable to be used as insulation for gas insulated switchgear.
          (Dry air insulation is an option)
                                                                                                                                                                              MITSUBISHI HS-X   02
                       RATINGS
                       GENERAL
                                                   Standard                                                                IEC 62271-200†1
                       Rated voltage                                               kV                             12                                 24
                       Rated frequency                                             Hz                                            50 / 60
                       Rated normal current of main busbars                        A                                           630 / 1250
                       Rated insulation levels                       LIWV          kV (peak)                      75                                125
                                                                     AC (1min)     kV (rms)                       28                                 50
                       Rated short-time withstand current                          kA                                               25
                       Rated duration of short-time current                        sec                                               3
                       Insulation medium                                                                                      SF6 / Dry air†2
                       Rated gas pressure †1                                       MPa-abs                SF6        : 0.13                     SF6       : 0.13
                                                                                                          Dry air    : 0.17                     Dry air   : 0.17
                       Alarm gas pressure †1                                       MPa-abs                SF6        : 0.12                     SF6       : 0.12
                                                                                                          Dry air    : 0.15                     Dry air   : 0.15
                                                                              †1 : The application standard is for 630A rating with dry air only. Others are IEC 60298.
                                                                              †2 : Insulation medium of dry air is an option and for 630A rating only.
03   MITSUBISHI HS-X
FEATURES
BUS
VCB
Electro-magnetic VCB
operating mechanism                       Plug-in termination (Option)           Wide range current transformer
A reduced number of parts increases       Reduces the time required for cable    The ratios of the current transformers
the reliability of the VCB. Also, a       termination work. Also cable volt-     can be changed without physically
reduction in the required energy to       age withstand testing can be easily    changing the CTs in combination with
operate the VCB is achieved.              performed by using a test terminal     multi-function relay (MP), providing
                                          without removing the cables.           great flexibility.
Test terminal
Cable
                                                                                                                              MITSUBISHI HS-X   04
                       COMPONENTS
                       ■ Reliability increase
                         The structure of the electro-magnetic operating mechanism is
                         more simple than that of the motor-spring operating mechanism,
                         and required 35% less parts which significantly reduces the
                         chances of failures.
                       ■ Maintenance reduction
                         With the use of an electro-magnetic operating mechanism,
                         there is no need for major maintenance for over 15 years.†1
                         †1 : The service life of the capacitor should be 15 years under normal operation conditions.
                       Auxiliary power
                                                  Equipment                                                                    Capacity                                Remarks
                        VCB                          Capacitor charging current                                                    DC 110V
                        Electrical-magnet                                                                               I(A)       (Open)I=5A,T=0.02 Sec
                        operation                                                                                                  (Close)I=0.4A,T=3.5 Sec
                                                                                                                         T(S)
0.2(ms)
3(s)
05   MITSUBISHI HS-X
Three position switch
An earthing switch is unified with the disconnecting
switch. The earthing switch is manually operated
however the disconnecting switch is manually operated
with motor operation as an option.
Main busbar
The main busbar is independently and solidly insulated                                                     Earth screen   Solidly insulated bus
: Out of scope
Cable
accidents. DS
                                                                          FRONT
                                                                                                 VCB
CABLE
■ Protection                          ■ Control
  Overcurrent (50/51),                 CB control / Lock out / Remote operation.
  Directional ground fault (67G),     ■ Measurement
  Ground fault (51G),                   A, V, W, Wh, Var, Varh, Hz, PF
  Undervoltage (27),                  ■ Communication
  Overvoltage (59),                     Modbus®RTU†1, CC-link, CDL protocols are
  Ground fault overvoltage (64)         available.
                                        †1 : Modbus® is a registered trademark of Schneider Electric SA.
                                                                                                                                                                           MITSUBISHI HS-X   06
                       SAFE OPERATION & USER FRIENDLY
                       Safe operation
                       The surface of the solid insulation on the main busbars, voltage transformer, cable termination and gas vessel which is earthed,
                       prevents electric shocks even when accidental contact occurs while the panel is energized.
                                                                                      Earth shield
                                                                                      (Carbon film)                            Busbar (Copper)
                                                                                                                               Insulation material
                                                                                                                               (Silicon rubber)
0 d
                       User friendly
                       The mimic diagram provides easy understanding of the VCB and DS / ES conditions. Mitsubishi HS-X provides easy operation and
                       prevents mal-operation by having a simple to understand and conveniently located (around eye level) operating mechanisms.
07   MITSUBISHI HS-X
A-2 The VCB mechanism provides simple operation from closed to opened condition by the use of a manual trip handle as
    described below.
Open the cover Attach the adaptor Apply the handle Pull down the handle
                                                                                                     Test terminal
■ The shutter operation key ensures that the DS / ES are operated
  separately and also provides a locking function.
DS / ES operation
■ Since the cable terminations are standard IEEE / DIN size, installation is
  very easy.
                                                                                                  Busbar arrangement
                                                                                                                                   MITSUBISHI HS-X   08
                       HIGH RELIABILITY AND COMPACT SIZE
Global warming potential (GWP) Condition: Lightning impulse voltage 1.2 / 50μs
                       Compact size
                       The compact size of the switchgear is achieved by the use of
                       suitably positioned insulating barriers within the hermetically
                                                                                                                                                    HS-X range
                       sealed vessel. The graph on the right demonstrates that the
                       breakdown voltage can be increased to more than double (or                                              2.5
                                                                                                                                                                        A                  B
                       conversely the insulation clearance distance can be decreased
                                                                                                                                                                                             a
                                                                                                                                                                                                   Needle
                       to less than half) of that when no barriers are used.                                                     2                                       Barrier         d
                                                                                              Breakdown voltage V / Vo (pu)
                                                                                                                                                                                  A : φ100mm
                                                                                                                                                                                  B : 300mm×300mm
                                                                                                                                                                                   (t=3mm)
                       HS-X requires 55% less †1 installation space when compared                                              1.5                                                d : 100mm
                       to its previous model.         This allows for it to be installed in
                       many locations where space is limited.
                                                                                                                                 1
                       †1 : Based on 10 panel arrangement and maintenance space.
                                                                                                                                         Condition: Lightning impulse voltage 1.2 / 50μs
                                                                                                                               0.5
09   MITSUBISHI HS-X
                                700                           7000
                                                                                          700
                                                                                                                                                      400                          6000
                                                                                                                                                                                                              50
                                                                                          1650
                                                   EXISTING MITSUBISHI
                                                   PREVIOUS MITSUBISHI GIS
                                                                       GIS
                                                                                                                                                                                                              1020
                                                                                                                                                                                  HS-X
                                                                                                       Space reduction of
                                                                                                            55%
                                                                                                                                                                                                              1000
                                                                                                                                                                       MAINTENANCE SPACE †2
                                                                                          1500
FRONT
                                                          FRONT
                                                                                                                                                                                                                           Unit : mm
                                                                                                                                                                         †2 : Maintenance space required is recommendation only.
                                0.8                                                                                                                  100.0
                                                                                                                                                                      Before oxidation stability test
                                                                       Mitsubishi grease
                                                                                                                                                      80.
                                                                                                                Transmittance(%)
                                                                                                                                                      60.
                                0.6
                                                                                                                                                              After oxidation stability test
                                                                     Bentonite-based grease                                                           40.
      Pressure of oxygen(MPa)
                                0.5
                                                                                                                                                      20.
                                0.4
                                                                                                                                                      0
                                              Lithium soap-based grease                                                                                        3000 2000              1500            1000           500
                                0.3                                                                                                                                           Wave numbers(cm-1)
                                                                                                                                                                        IR spectrum of Mitsubishi grease
                                            Temperature : 150℃
                                0.2
                                            Mass of grease : 72g
                                                                                                                                                                                           Lithium soap-based grease
                                0.1
                                                                                                                           Coefficient of friction
0.3
                                0.0                                                                                                                    0.2
                                      0            50            100               150           200
                                                          Heating time(hr)
                                                                                                                                                       0.1
                                      0                  10                 20                   30                                                                                            Mitsubishi grease
                                                                                                                                                                                                                                       MITSUBISHI HS-X   10
                       SWITCHGEAR ARRANGEMENT
TR TR
                                                                                                 VD                                      VD
                                                                                3×LA                                     3×LA
CT CT
VCB VCB
3×EVT DS / ES DS / ES 3×EVT
ES ES
DS / ES VCB
DS / ES DS / ES DS / ES DS / ES DS / ES DS / ES
CT CT CT CT CT
                                   DS /     DS /          DS /          DS /                ES          DS /                    ES           DS /          DS /         DS /            DS /
                                   ES       ES            ES            ES                              ES                                   ES            ES           ES              ES
                                   VCB      VCB           VCB           VCB           3×EVT             VCB               3×EVT              VCB           VCB          VCB             VCB
                                   CT       CT            CT            CT                                                                   CT            CT           CT              CT
                                                                 3×LA                                                                 3×LA
VD VD
E.BUS
600 600 600 600 600 600 600 600 600 600 600 600 1020
11   MITSUBISHI HS-X
Typical key single line & section view
                                 Incoming panel                      Outgoing panel                                   Bus section panel                          Bus EVT / LA panel
                                                   DS/ES                               DS/ES
                                                                                                                                  DS/ES                                           RL
ES DS ES DS ES DS RL
LA
EVT
                                                                                                               3×EVT
                                      DS/ES                                  DS/ES                                                                 DS/ES
                                                                                                                                                                                   ES
                                                                                                              DS/ES
Typical key single                                                           VCB
line                                   VCB                      3×LA
                                                                                                               VCB                                 VCB
                                                                                                                                                                           3×LA
                                                                                 3×EVT
                                CT                                                                                                                                                     3×EVT
                                                                                                        CT
                                       VD                            CT
                                                                                                               VD
ES DS ES DS ES DS ES DS ES
LA LA
EVT EVT
                                                                                                                            50 (75)
                                           100 (250)             80
                                   100
                                             55 (90)
                                                                                                                                            FRONT
                                                                                                                                                                        Foundation bolt†2
                                                                                                                                                        Floor
                                   400
400
                                                                                                                                      600
                                           FRONT
                                                                                                                            50 (75)
                                                                                                                                                                55      Embedded channel base†2        350
                                                                                                                                                                                            1020
                                                         700
                                Hole for control cable         Hole for main circuit cable   Foundation bolt hole size 20                                                         Cross-section view
                                                                   and earthing cable
                                                       Side space
13   MITSUBISHI HS-X
STANDARD ACCESSORIES
LV compartment key
Test plug
DS / ES operation handle
Gas adapter
OPTION
CBM (Condition Based Maintenance) System
CBM system is the maintenance system based on the equipment condition. It has two advanced points compared
to Time Based Maintenance system requires periodical maintenance.
    Without                     With
  CBM function               CBM function
                                                        Main periodical inspection item                      Items automatically
                                Major              Class                         Part                        monitored by CBM
                              inspection
      Major                     Minor                          Insulation,
                                                Switchgear                                            • Partial discharge monitoring †1
    inspection                inspection                       gas pressure †2