DATA S H E E T
AN 130
Flow sensor for water temperatures from 5 °C to
130 °C, PN 16 and PN 25
The flow sensors AN 130 are multi-jet dry dial vane impeller hot water
meters, suitable for installing in central heating and cooling systems
and remote warning systems. With their built-in pulse sender they are
approved as flow sensors for heating meters according the European
measuring instruments directive 2014/32/EU (MID).
Versions for horizontal, rising and falling flow directions with screwings
(PN 16) or flanges (horizontal flow, PN 25) are available.
Pattern Approval
MAIN CHARACTERISTICS DE-12-MI004-PTB002
Fully dry dial meter with no gear
Typical Head Loss Curve
reduction in the wet chamber
Wear resistant tungsten carbibe /
sapphire
Magnetic coupling protected against
Headloss (bar)
magnetitegnet
Pulse sender safe from interference qp 1.5
qp 2.5
Easy to repair construction with external
qp 3.5
regulation
qp 6
qp 10
Technical Data Flowrate (m3/h)
Display 00000.000 m3
Working 16 bar
pressure 25 bar (Special version)
Working 10 ... 130 °C
temperature
Accuracy class Class 2 or 3
Pulse Sender
Pulse sender Reed switch
permanently installed
Cable length 2m
Load capacity max. 0.1 A, max. 28 V
AN130 FAN AN130 SAN
Contact max 105 Ohm
resistance
Pulse value 10 Litres / pulse
For other pulse values
see special versions
LB 1101 INT - 11.2020-0006
AN 130
Flow sensor for water temperatures from 5 °C to 130 °C, PN 16 and PN 25
Dimensions and Weight
Horizontal installation for threaded fittings, Type AN 130 qp ... AN R ... K 10
Size marking qp m3/h 1.5 1.5 2.5 3.5 6 6 10
Nom. connection size DN mm 15 20 20 25 25 32 40
Pipe connection thread 1)
d inches R¼ R¾ R¾ R1 R1 R5/4 R1½
Meter stub thread 2)
D inches G¾ G1 G1 G1¼ G1¼ G1½ G2
Installed length without fittings I mm 165 190 190 260 260 260 300
Installed length with fittings L mm 244 288 288 378 378 378 438
Height H mm 155 155 155 170 170 170 190
Height h mm 34 36.5 36.5 49 49 49 62
Width B mm 96 97 97 103 103 103 140
Weight of meter without fittings ~kg 1.6 2.0 2.1 2.9 2.9 2.9 5.2
Weight of meter with fittings ~kg 2.1 2.5 2.6 3.6 3.6 3.6 6.5
Horizontal installation with flanges, Type AN 130 qp ... AN R ... K 10
Size marking qp m3/h 1.5 2.5 3.5 6 10
Nom. connection size DN mm 20 20 25 25 40
Installed length L mm 190 190 260 260 300
Height H mm 157 157 179 179 197
Height h mm 46 46 51 51 68
Flange diameter D mm 105 105 115 115 150
Width B mm 95 95 101 101 131
Weight ~kg 3.5 3.5 4.8 4.8 8
Installation in falling line for threaded fittings, Type AN 130 qp ... FAN R ... K 10
Size marking qp m3/h 1.5 2.5 3.5 6 10
Nom. connection size DN mm 20 20 25 25 40
Pipe connection thread 1)
d inches R¾ R¾ R1 R1 R1½
Meter stub thread 2) D inches G1 G1 G1¼ G1¼ G2
Installed length without fittings I mm 105 105 150 150 200
Installed length with fittings L mm 203 203 268 268 338
Height H mm 160 160 175 175 195
Height h mm 13 13 22 22 30
Axial offset b mm 100 100 105 105 120
Width B mm 97 97 103 103 140
Weight of meter without fittings ~kg 2 2.1 3.3 3.3 5
Weight of meter with fittings ~kg 2.3 2.4 3.8 3.8 6.3
Installation in rising line for threaded fittings, Type AN 130 qp ... SAN R ... K 10
Size marking qp m3/h 1.5 2.5 3.5 6 10
Nom. connection size DN mm 20 20 25 25 40
Pipe connection thread 1) d inches R¾ R¾ R1 R1 R1½
Meter stub thread 2)
D inches G1 G1 G1¼ G1¼ G2
Installed length without fittings I mm 105 105 150 150 200
Installed length with fittings L mm 203 203 268 268 338
Height H mm 155 155 170 170 190
Height h mm 19 19 33 33 30
Axial offset b mm 82 82 94 94 120
Width B mm 97 97 103 103 140
Weight of meter without fittings ~kg 2 2.1 3.3 3.3 5
Weight of meter with fittings ~kg 2.3 2.4 3.8 3.8 6.3
Connection thread dimensions: 1) d Withworth tapered pipe thread R ½" to R 2" to ISO 7/1 = DIN 2999 Part 1
2) D Pipe thread G 1 to G 2 B to DIN ISO 228/1
PAGE 2
AN 130
Flow sensor for water temperatures from 5 °C to 130 °C, PN 16 and PN 25
Materials Performance Data
Nominal size qp 1.5 2.5 3.5 6 10
Casing Brass, painted
Continuous loading qp m /h
3
1.5 2.5 3.5 6 10
Impeller Plastic
Max. flow rate (short-term) qs m /h
3
3 5 7 12 20
Impeller cup Plastic
Ratio qi : qp 1:50 1:50 1:50 1:50 1:50
Bearing pin Tungsten carbide
Minimum flow rate qi l/h 30 50 70 120 200
Tungsten Sapphire
carbide Pressure loss at qp bar 0.11 0.18 0.19 0.24 0.25
Magnetic Ceramic permanent Flow rate at 1 bar pressure loss m /h
3
4.7 6.0 8.1 12.2 20.1
coupling magnets
Order Information
Type Ordering Text Order No.
Horizontal version for threaded fittings - AN130 qp 1.5 AN R ¼" K 10 88189301
Pulse sender, 10 litres/pulse, according
AN130 qp 1.5 AN R ¾" K 10 88189300
MID directive
AN130 qp 2.5 AN R ¾" K 10 88189500
AN130 qp 3.5 AN R 1" K 10 88189700
AN130 qp 6 AN R 1" K 10 88189800
AN130 qp 6 AN R 5/4" K 10 88189801
AN130 qp 10 AN R 1½" K 10 88189900
Horizontal version with flanges, PN 16 - AN130 qp 1.5 ANF DN 20 K 10 88189304
Pulse sender, 10 litres / pulse, according
AN130 qp 2.5 ANF DN 20 K 10 88189504
MID directive
AN130 qp 3.5 ANF DN 25 K 10 88189704
AN130 qp 6 ANF DN 25 K 10 88189804
AN130 qp 10 ANF DN 40 K 10 88189904
Falling line version for threaded fittings - AN130 qp 1.5 FAN R ¾" K 10 88189303
Pulse sender, 10 litres / pulse, according
AN130 qp 2.5 FAN R ¾" K 10 88189503
MID directive
AN130 qp 3.5 FAN R 1" K 10 88189703
AN130 qp 6 FAN R 1" K 10 88189803
AN130 qp 10 FAN R 1½" K 10 88189903
Horizontal version with flanges, PN 25 - AN130 qp 1.5 ANF DN 20 K 10 88189351
Pulse sender, 10 litres / pulse, according
AN130 qp 2.5 ANF DN 20 K 10 88189551
MID directive
AN130 qp 3.5 ANF DN 25 K 10 88189751
AN130 qp 6 ANF DN 25 K 10 88189851
AN130 qp 10 ANF DN 40 K 10 88189951
Rising line version for threaded fittings - AN130 qp 1.5 SAN R ¾" K 10 88189302
Pulse sender, 10 litres / pulse, according
AN130 qp 2.5 SAN R ¾" K 10 88189502
MID directive
AN130 qp 3.5 SAN R 1" K 10 88189702
AN130 qp 6 SAN R 1" K 10 88189802
AN130 qp 10 SAN R 1½" K 10 88189902
UK & Ireland Inquiries | Sensus UK Systems Ltd. | 3 Lindenwood Crockford Lane, Chineham Business Park | Basingstoke RG24 8QY UK | +44 1256 372800 | info.gb@xyleminc.com
International Inquiries | Sensus GmbH Hannover | Meineckestr. 10 | 30880 Laatzen | Germany | +49 5102 743177 | info.int@xyleminc.com
©2020 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at sensus.com. Sensus reserves the right to modify these terms and conditions in its
own discretion. The Sensus logo and other Sensus products or services referenced are registered trademarks of Sensus.
This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS
PROHIBITED.