NUBIS MWN 130-NC
Propeller flow sensor with horizontal rotor
axis DN40 to DN300
    NUBIS MWN 130-NC
    The product is a propeller flow sensor intended for heat meters, with a horizontal rotor axis, aligned in parallel to
    the water piping centre line, and a low startup threshold. The latest engineering and processing design solutions
    applied in the product provide reliable readings and facilitate integration in non-standard installation configurations,
    including intermediate orientations between the horizontal and vertical ones, without any impact on the metrological
    ratings.
    Application
    MWN 130-NC is a propeller flow sensor intended for integration with an indicating calculator of a heat meter. The
    propeller flow sensor can be applied in water metering systems with the medium temperature between 0.1°C and
    130°C and a maximum operating pressure of the medium at 16 bars (PN 16). The propeller flow sensor can be installed
    in horizontal piping (H) with the counter upward or in vertical or tilted piping (V) with the counter to the side - or at
    any orientation in between the two (H/V) — of heat supply systems at multi-family houses or industrial facilities
                                                                                                   Standard NC pulse transmitter
                                                                                                   wiring length: 2 m
    Protection against external,
    mechanical or magnetic tampering
                                                                                                   Reed relay NC pulse transmitter
    with the counter mechanism
                                                                                                   unit
    and magnetic coupling
                                                                                                   Rotor assembly with double-sided
                                                                                                   (hard) bearings
    Interchangeable metering unit
                                                                                                   Epoxy powder coating with
                                                                                                   superior anti-corrosive resistance
2
Advantages
Safety:
 protection against:
    – magnetic field tampering (anti-magnetic shields),
    – mechanical tampering (counter cover).
Convenience of use:
 easy installation,
 modular design.
Reliability:
 robust, heavy-duty design,
 unified interchangeable metering unit,
 high anti-corrosive and damage resistance performance of the paint coat (made by epoxy powder coating).
Key features
   wide measurement range with a low starting threshold,
   hard propeller bearings,
   environmental class C,
   hermetically sealed dial and barrel counter,
   counter mechanism rotation lock at 360° of turn,
   easy reading by freely rotating the counter at any orientation,
   resistant to external magnetic fields Low pressure loss.
Regulatory and standard compliance
 Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the
  Member States relating to the making available on the market of pressure equipment
 EN 1434-1:2007 Heat meters, Parts 1-6
 OIML R 75:2002 and OIML R 75:2006 Heat meters, Parts 1-3
 EC type examination certificate no. SK 11-MI004-SMU001
 Classification of environmental, climate and mechanical conditions: Class B (ref. PN-EN 14154-3:2005:A1)
 Classification of mechanical environment conditions: Class M1 (ref. Polish Regulation Dz.U. 2006.12.18)
 Classification of electromagnetic environment conditions: Class E1 (ref. Polish Regulation Dz.U. 2006.12.18)
                                                                                                                              3
    Table 1. Technical data
     Typ MWN 130-                                                  40-   50-     65-           80-     100-         125-       150-   200-         250-    300-
                                                                   NC    NC      NC            NC       NC           NC         NC     NC           NC      NC
     Nominal diameter                           DN       mm        40    50      65            80      100          125        150    200          250     300
     Minimum flow rate                           qi      m3/h      0,6   0,6         1         1,6     2,4           4          6      10          40         60
     Nominal flow rate                           qp      m3/h      15    15      25            40      60           100        150    250          400     600
     Maximum flow rate                           qs      m3/h      30    30      50            80      120          200        300    500          800     1200
     Measurement range, R                      qp / qi     -       25    25      25            25       25          25         25      25          10          10
     Indicating range                             -       m3                             106                                                 107
     Resolution of reading                       -        m3                         0,0005                                           0,005                0,05
     Maximum
                                               MAP         -                                      PN16                                                  PN10
     permitted pressure
     Operating pressure range                     -      bar                                   od 0,3 do 16                                        od 0,3 do 10
     Maximum pressure loss                      ΔP         -                                         ΔP10 = (0,10 bar)
     Temperature range:                          -         -                               θ min = 0,10°C, θ max = 130°C
     Minimum upstream/
     dowstream                                    -      mm                                                   0
     straight-line piping length
     Operating orientation                       -         -                                                  H,V
     Maximum permitted error
                                                 Ef       %                                ±(3+0,05 qp/qi) and up to ±5%
     (accuracy class 3)
     Environmental class                         -         -                                                  C
     Reed relay NC pulse                                 dm /  3
                                                 -                                       100                                                1000
     transmitter                                         pulse
                                                                                           225
     Length                                      L       mm        200   200     200                   250          250        300    350          450     500
                                                                                           200*
                                                 H       mm        65    72      83            95      105          120        135    160          193     230
                                                 h       mm        177   187     197           219     229          257        357    382          427     497
     Height
                                               H1**      mm        277   287     297           339     349          377        582    607          652     722
                                                 Dz      mm        150   165     185           200     220          250        285    340          400     460
                                                                                           13,7 /
     Weight                                               kg       8,3   10,3    11                     16        18,5         40,5   51,5         75,5   103,5
                                                                                           14,2*
    * On request.
    ** Metering unit's removal clear height.
    Flange bolt pattern: PN-EN 1092-2 (PS/PN: 10), DIN2532, DIN2501 (PN10), BS4504 (PN10);
    PS/PN: 16 (to DN 200) available on request.
                                                                                                                                                               H1
                                                                                Dz                                                                        H
4
Pressure loss chart
Pressure loss
                                               12 C
                                                    C
                                               25 C
                                                    C
                                                    C
                                           M N NC
                                               65 C
                                                  NC
                                               10 C
                                                 0N
                                                 5N
                                                 0N
                                            W 00 N
                                                 0N
                                                 0N
                                             N N
                                             N N
                                            W 0
                                            W 50
                                            W 80
                                               30
                                               15
mbar     kPa
                                               2
                                             N
                                           M N
                                             N
                                             N
                                             N
                                            W
                                            W
                                           M
                                           M
                                           M
                                           M
                                           M
1 000     1 00
 1 00      10
  10           1
     1    0,1
                   1                  10        1 00               1 000              1 0000
                                                                                  Flow [m3/h]
Typical error chart
Error [%]
 5
-1
-2
-3
-4
-5
                       qi                  qp                                qs
                                                                            Flow rate [m3/h]
Connections for a remote transmission of readings and flow rate measurement
                                                                                                                      WM-BUS
                                                                                                                      M-BUS
                                                                                                                      RS232/ RS485 Modbus RTU/Lumbus
                                                                    white
                                                Reed relay pulse                                                      LonWorks
                            Water meter         transmitter (NC)    brown                                 Faun        RS OPTO
                                                                                                                      analog outputs (4-20mA/1-10V)
                                                                                                                      pulse outputs
                                                                                                                      opto connector
                                                                                                                 W4
                                                                                                     W2
                                                                                                           W3
                                                                                                W1
                                                                                                                                                       5
The data shown here is current on the date of issue.
The manufacturer has the right to modify and improve the products without notice.
This publication is indicative only and should not be construed as a commercial offer under the Polish Civil Code.
Apator Powogaz S.A.
Jaryszki 1c, 62-023 Żerniki, Poland
Office: sekretariat.powogaz@apator.com, tel. +48 61 84 18 101
Sales / Customer Service: tel.: +48 61 84 18 149
Customer Service Centre Support: handel.powogaz@apator.com
Export: export.powogaz@apator.com
Technical Support: support.powogaz@apator.com, tel. +48 61 8418 131, 134, 294
Warranty Claims: reklamacje.powogaz@apator.com
www.apator.com                                                                                                       2023.022.EN