Sensing distance Supply voltage Output

12 to 24 VDC

100 mA
(Optical fiber series)

Optical Fiber Photoelectric Sensor E3X

Leading-edge Features and


Long-distance Sensing in an Optical
Fiber Photoelectric Sensor
E3X-Tjj with Auto-tuning Function
Automatic Sensitivity Adjustment

E3X-H11 High-sensitivity Model


Senses Distances Twice as Far as those of
E3X-Ajj and Performs Detailed Sensing
Operations Using the Variable Hysteresis
Function

E3X-Ajj Standard Model


A High-speed Response of 200 µs

E3X-Fjj High-speed Model


Pulse Lighting Mechanism Enables a
High-speed Response of 20 µs

E3X-VGjj Mark Sensor Model


Green Light Source Accurately Senses Subtle
Differences in Color at a Speed of 200 ms

Ordering Information
Model Number Legend:
E3X -
1 2 3 4
1. Classification 3. Outputs
T: Auto-tuning 1: NPN (without self-diagnosis)
H: High-sensitivity 2: NPN (with self-diagnosis)
A: General-purpose 4: PNP (without self-diagnosis)
F: Shorter response time 5: PNP (with self-diagnosis)
V: For mark sensor 4. Output Form
2. Light Source 1: Cable
None: Red (standard)
G: Green

Accessories (Order Separately)


(Cannot be used with the E3X-Tjj.)

1
E3X E3X

Item Manual Sensitivity Adjustment Knob Protective Cover


Application Makes adjustment possible without Replacement part for cover supplied with
screwdriver. Water-resistance lost when used Amplifier Unit.
(enclosure rating reduced to IP50).
Model E39-G3 E39-G4
Appearance

Amplifier Units
Item Auto-tuning High-sensitivity
Model E3X-T11 E3X-T21 E3X-H11
Appearance

32

59
12

Light source Red LED (660 nm)


Power supply voltage 12 to 24 VDC +10%, ripple (p-p) 10% max. 10 to 30 VDC +10%, ripple
(p-p) 10% max.
Current consumption 50 mA max. 35 mA max.
Response time 500 ms max. 1 m sec max.
Control output 100 mA max. at 30 VDC, NPN open collector
Timer function --- OFF-delay timer (fixed to 40 ms), switch selectable
Self-diagnosis alarm output --- 50 mA max. at 30 VDC, open ---
collector
Variable hysteresis function --- 0% to 20%
Tuning monitor function Indicator (red/green LED) and buzzer ---
Remote tuning function/ --- When ON, short-circuit the ---
Remote bank function blue and pink wires.
(Short-circuit the blue and
purple wires for remote bank
selection.):
Short-circuit voltage 3 V
max., short-circuit current
5 mA min.
When OFF, open the blue
and pink wires: 9 V min.
(input voltage: 24 V max.),
response time 100 ms max.
when OFF.
Output method Light ON and Dark ON selector

2
E3X E3X

Item General-purpose Shorter response For mark sensing


time
Model NPN E3X-A11 E3X-A21 E3X-F21 E3X-VG11 E3X-VG21
PNP E3X-A41 E3X-A51 E3X-F51 --- ---
Appearance

Light source Red (660 nm) Green (565 nm)


Power supply voltage 10 to 30 VDC ripple (p-p) 12 to 24 VDC +10% 10 to 30 VDC ripple (p-p) 10% max.
10% max. ripple (p-p)
10% max.
Current consumption 35 mA max. 40 mA max.
Response time 200 ms max. ON: 20 ms max. 200 ms max.
OFF: 30 ms max.
Control output 100 mA, 30 VDC max., Open collector
Timer function --- OFF-delay timer (0.01 to 0.1 s; --- OFF-delay timer
adjustable), Switch selectable (0.01 to 0.1 s;
adjustable),
Switch selectable
Self-diagnosis alarm output --- 50 mA, 30 VDC max. --- 50 mA, 30 VDC
Residual voltage: 1 VDC max. max.
Residual voltage: 1
VDC max.
External Input voltage --- Light OFF: --- Light OFF: 1.5 V
diagnosis input NPN: 1.5 V max; short current: 0.2 mA max;
max. short current: 0.2 mA
PNP: ±1.5 V max.; short current: max.
0.2 mA max. Light ON: Open;
Light ON: 3.5 V min. (max.
NPN: Open; Light OFF: 3.5 V min. input: 5 V)
(max. input: 5 V)
PNP: Open; ±3.5 VDC max.
(max. input: 5 V)
Response delay 400 ms 200 ms 400 ms

3
E3X E3X

Fiber Unit
Through-beam (Separate) Sensors
Model Appearance Sensing distance (standard object)* Min. sensing object Features
(T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; (opaque objects)
F: E3X-Fjj; V: E3X-VGjj)
E32-T11L T: 500 mm (1,200 mm**) (1.4-mm dia. min.) T: 0.2-mm dia. Long distance
M4 screw H: 700 mm (2,000 mm**) (1.4-mm dia. min.) H: 0.5-mm dia.
A: 350 mm (1,000 mm**) (1.4-mm dia. min.) A: 0.5-mm dia.
F: 150 mm (1.4-mm dia. min.) F: 0.5-mm dia.
V: 40 mm (120 mm**) (1.4-mm dia. min.) V: 0.5-mm dia.
E32-T12L T: 500 mm (1.4-mm dia. min.) T: 0.2-mm dia. Long distance
H: 700 mm (1.4-mm dia. min.) H: 0.5-mm dia.
3-mm dia.
A: 350 mm (1.4-mm dia. min.) A: 0.5-mm dia.
F: 150 mm (1.4-mm dia. min.) F: 0.5-mm dia.
V: 40 mm (1.4-mm dia. min.) V: 0.5-mm dia.
E32-T21L T: 150 mm (0.9-mm dia. min.) 0.2-mm dia. Long distance with
M3 screw H: 200 mm (0.9-mm dia. min.) thin fiber
A: 100 mm (0.9-mm dia. min.)
F: 50 mm (0.9-mm dia. min.)
V: 10 mm (0.9-mm dia. min.)
E32-T22L T: 150 mm (0.9-mm dia. min.) 0.2-mm dia. Long distance with
H: 200 mm (0.9-mm dia. min.) thin fiber
2-mm dia.
A: 100 mm (0.9-mm dia. min.)
F: 50 mm (0.9-mm dia. min.)
V: 10 mm (0.9-mm dia. min.)
E32-TC200 T: 270 mm (2,000 mm**) (1-mm dia. min.) 0.2-mm dia. General-purpose
M4 screw H: 400 mm (3,000 mm**) (1-mm dia. min.)
A: 200 mm (1,500 mm**) (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
V: 28 mm (190 mm**) (1-mm dia. min.)
E32-TC200B T: 270 mm (1-mm dia. min.) 0.2-mm dia. General-purpose
E32-TC200B4 M4 screw H: 400 mm (1-mm dia. min.)
A: 180 mm (1-mm dia. min.)
F: 80 mm (1-mm dia. min.)
V: 28 mm (1-mm dia. min.)
E32-T22 T: 70 mm (0.5-mm dia. min.) 0.2-mm dia. General-purpose
H: 100 mm (0.5-mm dia. min.)
2-mm dia.
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 7 mm (0.5-mm dia. min.)
E32-TC200E T: 70 mm (0.5-mm dia. min.) 0.2-mm dia. General-purpose
M3 screw H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 8 mm (0.5-mm dia. min.)
E32-TC200F T: 70 mm (0.5-mm dia. min.) 0.2-mm dia. General-purpose
E32-TC200F4 M3 screw H: 100 mm (0.5-mm dia. min.)
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 8 mm (0.5-mm dia. min.)
E32-TC200A T: 250 mm (1-mm dia. min.) T: 0.2-mm dia. General-purpose
H: 360 mm (1-mm dia. min.) H: 0.3-mm dia.
M3 screw
A: 180 mm (1-mm dia. min.) A: 0.2-mm dia.
F: 80 mm (1-mm dia. min.) F: 0.2-mm dia.
V: 28 mm (1-mm dia. min.) V: 0.2-mm dia.
E32-T11 T: 240 mm (1,300 mm**) (1-mm dia. min.) T: 0.2-mm dia. Flexible (resists
H: 360 mm (1-mm dia. min.) H: 0.3-mm dia. breaking)
M4 screw
A: 180 mm (1,000 mm**) (1-mm dia. min.) A: 0.2-mm dia.
F: 80 mm (1-mm dia. min.) F: 0.2-mm dia.
V: 10 mm (120 mm**) (1-mm dia. min.) V: 0.2-mm dia.
E32-T21 T: 65 mm (0.5-mm dia. min.) 0.2-mm dia. Flexible (resists
H: 100 mm (0.5-mm dia. min.) breaking)
M3 screw
A: 50 mm (0.5-mm dia. min.)
F: 26 mm (0.5-mm dia. min.)
V: 6 mm (0.5-mm dia. min.)
*Standard object: opaque; **For the E39-F1; ***Not trimmable

4
E3X E3X

Model Appearance Sensing distance (standard object)* Min. sensing object Features
(T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; (opaque objects)
F: E3X-Fjj; V: E3X-VGjj)
E32-TC200C T: 200 mm (800 mm**) (1-mm dia. min.) 0.2-mm dia. Flexible spiral cord
H: 300 mm (1,600 mm**) (1-mm dia. min.)
M4 screw **** A: 150 mm (800 mm**) (1-mm dia. min.)
F: 60 mm (1-mm dia. min.)
V: 18 mm (100 mm) (1-mm dia. min.)
E32-TC200D T: 200 mm (1-mm dia. min.) 0.2-mm dia. Flexible spiral cord
E32-TC200D4 H: 300 mm (1-mm dia. min.)
M4 screw **** A: 150 mm (1-mm dia. min.)
F: 60 mm (1-mm dia. min.)
V: 18 mm (1-mm dia. min.)
E32-T14L T: 130 mm (1-mm dia. min.) T: 0.3-mm dia. Side-view;
3-mm dia.
H: 240 mm (1-mm dia. min.) H: 0.2-mm dia. long distance
A: 120 mm (1-mm dia. min.) A: 0.1-mm dia.
F: 30 mm (1-mm dia. min.) F: 0.2-mm dia.
V: 10 mm (1-mm dia. min.) V: 0.1-mm dia.
E32-T24 1-mm dia.
T: 45 mm (0.5-mm dia. min.) T: 0.2-mm dia. Side-view;
H: 90 mm (0.5-mm dia. min.) H: 0.1-mm dia. save space
A: 45 mm (0.5-mm dia. min.) A: 0.1-mm dia.
F: 15 mm (0.5-mm dia. min.) F: 0.3-mm dia.
V: 2 mm (0.5-mm dia. min.) V: 0.2-mm dia.
E32-T14 T: 1,000 mm (4-mm dia. min.) T: 0.2-mm dia. Side-view
H: 1,800 mm (4-mm dia. min.) H: 1-mm dia.
A: 900 mm (4-mm dia. min.) A: 1-mm dia.
F: 380 mm (4-mm dia. min.) F: 0.2-mm dia.
V: 80 mm (4-mm dia. min.) V: 2-mm dia.
E32-T17L T: 7,000 mm (10-mm dia. min.) T: 0.7-mm dia. Long distance
H: 14,000 mm (10-mm dia. min.) H: 2.1-mm dia.
M4 screw
A: 7,000 mm (10-mm dia. min.) A: 0.8-mm dia.
F: 3,000 mm (10-mm dia. min.) F: 1.5-mm dia.
V: 800 mm (10-mm dia. min.) V: 2.1-mm dia.
E32-T12F T: 1,000 mm (4-mm dia. min.) T: 0.3-mm dia. Teflon-covered*****;
H: 1,600 mm (4-mm dia. min.) H: 0.7-mm dia. withstands
5-mm dia. A: 800 mm (4-mm dia. min.) A: 0.9-mm dia. chemicals and harsh
F: 300 mm (4-mm dia. min.) F: 0.7-mm dia. environments
V: 70 mm (4-mm dia. min.) V: 0.6-mm dia.
E32-M21 T: 200 mm (2-mm dia. min.) T: 0.2-mm dia. 4-head;
H: 300 mm (2-mm dia. min.) H: 0.4-mm dia. 4-point sensing
A: 150 mm (2-mm dia. min.) A: 0.3-mm dia.
M3 screw ****
F: 65 mm (2-mm dia. min.) F: 0.3-mm dia.
V: 20 mm (2-mm dia. min.) V: 0.3-mm dia.
E32-T51 T: 300 mm (1.5-mm dia. min.) T: 0.4-mm dia. Heat-resistant;
H: 400 mm (1.5-mm dia. min.) H: 1.0-mm dia. resists 150°C
M4 screw
A: 200 mm (1.5-mm dia. min.) A: 1.0-mm dia.
F: 80 mm (1.5-mm dia. min.) F: 1.0-mm dia.
V: 20 mm (1.5-mm dia. min.) V: 1.0-mm dia.
E32-T61 T: 180 mm (2,000 mm**) (1.0-mm dia. min.) T: 0.2-mm dia. Heat-resistant;
H: 300 mm (3,000 mm**) (1.0-mm dia. min.) H: 0.3-mm dia. resists 300°C
M4 screw ****
A: 150 mm (1,500 mm**) (1.0-mm dia. min.) A: 0.2-mm dia.
F: 60 mm (450 mm) (1.0-mm dia. min.) F: 0.5-mm dia.
V: 18 mm (130 mm**) (1.0-mm dia. min.) V: 0.5-mm dia.
*Standard object: opaque; **For the E39-F1.; ***Sensing distances for slit applications are in the following table.
****Not trimmable
*****Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.

5
E3X E3X
E32-T16 with Slits
Slit width 0.5-mm 1.0-mm Sensing method
With Sensing distance 450 mm 800 mm
Sensing object
E3X-Tjj Min. sensing object 0.2-mm dia. 0.3-mm dia.
With Sensing distance 900 mm 1,200 mm
E3X-H11 Min. sensing object 0.2-mm dia. 0.4-mm dia.
Slit
With Sensing distance 450 mm 600 mm
E3X-Ajj Min. sensing object 0.25-mm dia. 0.35-mm dia.
With Sensing distance 120 mm 250 mm
E3X-Fjj Min. sensing object 0.25-mm dia. 0.35-mm dia.
With Sensing distance 20 mm 60 mm
E3X-VGjj Min. sensing object 0.25-mm dia. 0.35-mm dia.

Reflective Sensors
Model Appearance Sensing distance (standard object) Min. sensing object Features
(T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; (copper wire)
F: E3X-Fjj; V: E3X-VGjj)
White paper Black paper
E32-D11L T: 150 mm (20 x 20 cm) T: 40 mm (20 x 20 cm) T: 0.015-mm dia. Long distance
M6 screw H: 200 mm (20 x 20 cm) H: 60 mm (20 x 20 cm) H: 0.015-mm dia.
A: 100 mm (10 x 10 cm) A: 30 mm (10 x 10 cm) A: 0.015-mm dia.
F: 45 mm (5 x 5 cm) F: 8 mm (5 x 5 cm) F: 0.2-mm dia.
V: 10 mm (2.5 x 2.5 cm) V: --- V: 3.0-mm dia.
E32-D12 T: 80 mm (10 x 10 cm) T: 20 mm (10 x 10 cm) T: 0.015-mm dia. Long distance
H: 120 mm (20 x 20 cm) H: 32 mm (20 x 20 cm) H: 0.015-mm dia.
3 mm dia.
A: 60 mm (10 x 10 cm) A: 16 mm (10 x 10 cm) A: 0.04-mm dia.
F: 15 mm (2.5 x 2.5 cm) F: 3 mm (2.5 x 2.5 cm) F: 2.4-mm dia.
V: 2 mm (2.5 x 2.5 cm) V: --- V: 1.6-mm dia.
E32-D21L T: 35 mm (5 x 5 cm) T: 9 mm (5 x 5 cm) T: 0.015-mm dia. Long distance
M4 screw
H: 50 mm (5 x 5 cm) H: 14 mm (5 x 5 cm) H: 0.015-mm dia.
A: 25 mm (2.5 x 2.5 cm) A: 7 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 11 mm (2.5 x 2.5 cm) F: 2 mm (2.5 x 2.5 cm) F: 0.26-mm dia.
V: 1 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D22L T: 35 mm (5 x 5 cm) T: 9 mm (5 x 5 cm) T: 0.015-mm dia. Long distance
H: 50 mm (5 x 5 cm) H: 14 mm (5 x 5 cm) H: 0.015-mm dia.
3 mm dia.
A: 25 mm (2.5 x 2.5 cm) A: 7 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 11 mm (2.5 x 2.5 cm) F: 2 mm (2.5 x 2.5 cm) F: 0.26-mm dia.
V: 1 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC200 T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm) T: 0.015-mm dia. General-purpose
H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm) H: 0.015-mm dia.
M6 screw A: 75 mm (10 x 10 cm) A: 15 mm (10 x 10 cm) A: 0.015-mm dia.
F: 33 mm (5 x 5 cm) F: 5 mm (5 x 5 cm) F: 0.015-mm dia.
V: 10 mm (2.5 x 2.5 cm) V: --- V: 0.2-mm dia.
E32-DC200B T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm) T: 0.015-mm dia. General-purpose
E32-DC200B4 H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm) H: 0.015-mm dia.
M6 screw A: 75 mm (10 x 10 cm) A: 15 mm (10 x 10 cm) A: 0.03-mm dia.
F: 33 mm (5 x 5 cm) F: 5 mm (5 x 5 cm) F: 0.03-mm dia.
V: 10 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC200E T: 20 mm (2.5 x 2.5 cm) T: 4.8 mm (2.5 x 2.5 cm) T: 0.015-mm dia. General-purpose
H: 36 mm (5 x 5 cm) H: 7.2 mm (5 x 5 cm) H: 0.015-mm dia.
M3 screw A: 18 mm (2.5 x 2.5 cm) A: 3.6 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 8 mm (2.5 x 2.5 cm) F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 2 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC200F T: 20 mm (2.5 x 2.5 cm) T: 4.8 mm (2.5 x 2.5 cm) T: 0.015-mm dia. General-purpose
E32-DC200F4 H: 36 mm (5 x 5 cm) H: 7.2 mm (5 x 5 cm) H: 0.015-mm dia.
M3 screw A: 18 mm (2.5 x 2.5 cm) A: 3.6 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 8 mm (2.5 x 2.5 cm) F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 2 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D11 T: 60 mm (10 x 10 cm) T: 13 mm (10 x 10 cm) T: 0.015-mm dia. Flexible (resists
H: 90 mm (10 x 10 cm) H: 20 mm (10 x 10 cm) H: 0.015-mm dia. breaking)
M6 screw A: 45 mm (5 x 5 cm) A: 10 mm (5 x 5 cm) A: 0.03-mm dia.
F 20 mm (2.5 x 2.5 cm) F: 5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 7 mm (2.5 x 2.5 cm) V: --- V: 0.5-mm dia.

6
E3X E3X

Model Appearance Sensing distance (standard object) Min. sensing object Features
(T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; (copper wire)
F: E3X-Fjj; V: E3X-VGjj)
White paper Black paper
E32-D21 T: 8 mm (2.5 x 2.5 cm) T: 1.6 mm (2.5 x 2.5 cm) T: 0.015-mm dia. Flexible (resists
H: 14 mm (2.5 x 2.5 cm) H: 3 mm (2.5 x 2.5 cm) H: 0.015-mm dia. breaking)
M3 screw A: 7 mm (2.5 x 2.5 cm) A: 1.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 3 mm (2.5 x 2.5 cm) F: --- F: 0.03-mm dia.
V: 1 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC200C T: 30 mm (5 x 5 cm) T: 6 mm (5 x 5 cm) T: 0.015-mm dia. Flexible spiral
H: 44 mm (5 x 5 cm) H: 10 mm (5 x 5 cm) H: 0.015-mm dia. cord
** A: 22 mm (2.5 x 2.5 cm) A: 4.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
M6 screw
F: 10 mm (2.5 x 2.5 cm) F: --- F: 0.03-mm dia.
V: 2.5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC200D T: 30 mm (5 x 5 cm) T: 6 mm (5 x 5 cm) T: 0.015-mm dia. Flexible spiral
E32-DC200D4 H: 44 mm (5 x 5 cm) H: 10 mm (5 x 5 cm) H: 0.015-mm dia. cord
** A: 22 mm (2.5 x 2.5 cm) A: 4.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
M6 screw
F: 10 mm (2.5 x 2.5 cm) F: --- F: 0.03-mm dia.
V: 2.5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-DC9G T: 35 mm (5 x 5 cm) T: 7 mm (5 x 5 cm) T: 0.015-mm dia. Stainless steel
E32-DC9G4 H: 60 mm (10 x 10 cm) H: 12 mm (10 x 10 cm) H: 0.015-mm dia. sleeve
1.2-mm dia. ** A: 30 mm (5 x 5 cm) A: 6 mm (5 x 5 cm) A: 0.03-mm dia.
F: 9 mm (2.5 x 2.5 cm) F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 2.5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D33 T: 6 mm (2.5 x 2.5 cm) T: 1.3 mm (2.5 x 2.5 cm) T: 0.015-mm dia. Super-thin; detail
3-mm dia.
H: 10 mm (2.5 x 2.5 cm) H: 2 mm (2.5 x 2.5 cm) H: 0.015-mm dia. sensing
0.8-mm dia. A: 5 mm (2.5 x 2.5 cm) A: --- A: 0.015-mm dia.
F: 1.8 mm (2.5 x 2.5 cm) F: --- F: 0.03-mm dia.
V: --- V: --- V: ---
E32-CC200 T: 100 mm (10 x 10 cm) T: 20 mm (10 x 10 cm) T: 0.015-mm dia. Coaxial;
H: 150 mm (20 x 20 cm) H: 30 mm (20 x 20 cm) H: 0.015-mm dia. positioning
M6 screw A: 75 mm (10 x 10 cm) A: 15 mm (10 x 10 cm) A: 0.03-mm dia. accuracy
F: 33 mm (5 x 5 cm) F: 6 mm (5 x 5 cm) F: 0.03-mm dia.
V: 10 mm (2.5 x 2.5 cm) V: 2 mm (2.5 x 2.5 cm) V: 0.5-mm dia.
E32-D32 T: 30 mm (2.5 x 2.5 cm) T: 5.3 mm (2.5 x 2.5 cm) T: 0.015-mm dia. General-purpose
H: 40 mm (5 x 5 cm) H: 8 mm (5 x 5 cm) H: 0.015-mm dia.
2-mm dia. A: 20 mm (2.5 x 2.5 cm) A: 4 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 9 mm (2.5 x 2.5 cm) F: 1.5 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 2.5 mm (2.5 x 2.5 cm) V: --- V: 0.5-mm dia.
E32-D32L T: 60 mm (10 x 10 cm) T: 10 mm (10 x 10 cm) T: 0.015-mm dia. General-purpose
H: 80 mm (10 x 10 cm) H: 16 mm (10 x 10 cm) H: 0.015-mm dia.
3-mm dia. A: 40 mm (5 x 5 cm) A: 8 mm (5 x 5 cm) A: 0.04-mm dia.
F: 11 mm (2.5 x 2.5 cm) F: 4 mm (2.5 x 2.5 cm) F: 1.1-mm dia.
V: 4 mm (2.5 x 2.5 cm) V: --- V: 1-mm dia.
E32-D14L 6-mm dia. T: 40 mm (5 x 5 cm) T: 8 mm (5 x 5 cm) T: 0.03-mm dia. Side-view;
H: 40 mm (5 x 5 cm) H: 8 mm (5 x 5 cm) H: 0.03-mm dia. long distance
A: 40 mm (5 x 5 cm) A: 8 mm (5 x 5 cm) A: 0.03-mm dia.
F: 12 mm (2.5 x 2.5 cm) F: 2 mm (2.5 x 2.5 cm) F: 0.5-mm dia.
V: 1.5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D24 T: 15 mm (2.5 x 2.5 cm) T: 2.5 mm (2.5 x 2.5 cm) T: 0.03-mm dia. Side-view;
2-mm dia.
H: 15 mm (2.5 x 2.5 cm) H: 2.5 mm (2.5 x 2.5 cm) H: 0.03-mm dia. save space
A: 15 mm (2.5 x 2.5 cm) A: 2.5 mm (2.5 x 2.5 cm) A: 0.03-mm dia.
F: 4 mm (2.5 x 2.5 cm) F: --- F: 0.03-mm dia.
V: 1.6 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D12F T: 50 mm (5 x 5 cm) T: 15 mm (5 x 5 cm) T: 0.03-mm dia. Teflon-cov-
H: 50 mm (5 x 5 cm) H: 15 mm (5 x 5 cm) H: 0.03-mm dia. ered***; with-
6-mm dia. A: 50 mm (5 x 5 cm) A: 15 mm (5 x 5 cm) A: 0.03-mm dia. stands chemi-
F: 20 mm (2.5 x 2.5 cm) F: 6 mm (2.5 x 2.5 cm) F: 0.5-mm dia. cals and harsh
V: 4 mm (2.5 x 2.5 cm) V: --- V: 0.5-mm dia. environments
*Standard object: opaque
**Not trimmable
***Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.

7
E3X E3X

Model Appearance Sensing distance (standard object) Min. sensing object Features
(T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; (copper wire)
F: E3X-Fjj; V: E3X-VGjj)
White paper Black paper
E32-D51 T: 60 mm (10 x 10 cm) T: 12 mm (10 x 10 cm) T: 0.03-mm dia. Heat-resistive;
H: 120 mm (20 x 20 cm) H: 24 mm (20 x 20 cm) H: 0.03-mm dia. resists 150°C
M6 screw A: 60 mm (10 x 10 cm) A: 12 mm (10 x 10 cm) A: 0.03-mm dia.
F: 26 mm (5 x 5 cm) F: 5 mm (5 x 5 cm) F: 0.03-mm dia.
V: 5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D61 T: 45 mm (5 x 5 cm) T: 9 mm (5 x 5 cm) T: 0.03-mm dia. Heat-resistive;
**
H: 45 mm (5 x 5 cm) H: 9 mm (5 x 5 cm) H: 0.03-mm dia. resists 300°C
M6 screw A: 45 mm (5 x 5 cm) A: 9 mm (5 x 5 cm) A: 0.03-mm dia.
F: 20 mm (2.5 x 2.5 cm) F: 4 mm (2.5 x 2.5 cm) F: 0.03-mm dia.
V: 5 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-D73 T: 30 mm (5 x 5 cm) T: 6 mm (5 x 5 cm) T: 0.03-mm dia. Heat-resistive;
**
H: 30 mm (5 x 5 cm) H: 6 mm (5 x 5 cm) H: 0.03-mm dia. resists 400°C
M4 screw 1.25-mm dia. A: 30 mm (5 x 5 cm) A: 6 mm (5 x 5 cm) A: 0.03-mm dia.
F: 17 mm (2.5 x 2.5 cm) F: 3 mm (2.5 x 2.5 cm) F: 0.2-mm dia.
V: 3 mm (2.5 x 2.5 cm) V: --- V: 1.0-mm dia.
E32-R21 T: 25 to 250 mm --- T: 0.6-mm dia. Transparent
/E39-R3 (35-mm dia. min.) H: 0.3-mm dia. objects sensing
M6 screw Reflector H: 10 to 250 mm A: 0.3-mm dia.
E39-R3 (35-mm dia. min.) F: 0.5-mm dia.
A: 10 to 250 mm V: ---
(35-mm dia. min.)
F: 20 to 230 mm
(35-mm dia. min.)
V: ---
E32-R16 T: 150 to 1,500 mm --- T: 1.9-mm dia. Transparent
/E39-R1 (35-mm dia. min.) H: 0.6-mm dia. objects sensing
Reflector H: 150 to 1,500 mm A: 0.6-mm dia.
E39-R1 (35-mm dia. min.) F: 0.6-mm dia.
A: 150 to 1,500 mm V: ---
(35-mm dia. min.)
F: 50 to 700 mm
(35-mm dia. min.)
V: ---
E32-L25 T: 3.3 mm (2.5 x 2.5 cm) --- T: 0.015-mm dia. Limited
H: 3.3 mm (2.5 x 2.5 cm) H: 0.015-mm dia. reflective;
A: 3.3 mm (2.5 x 2.5 cm) A: 0.03-mm dia. senses wafers
F: 3.3 mm (2.5 x 2.5 cm) F: 0.5-mm dia. and small
V: --- V: --- difference in
height
E32-L25A T: 3.3 mm (2.5 x 2.5 cm) --- T: 0.015-mm dia. Limited
H: 3.3 mm (2.5 x 2.5 cm) H: 0.015-mm dia. reflective;
A: 3.3 mm (2.5 x 2.5 cm) A: 0.03-mm dia. senses wafers
F: 3.3 mm (2.5 x 2.5 cm) F: 0.5-mm dia. and small
V: --- V: --- difference in
height
E32-L25L H: 7.2±1.8 mm --- H: 0.015-mm dia. Limited
(2.5 x 2.5 cm) A: 0.015-mm dia. reflective, long
A: 7.2±1.8 mm F: 0.015-mm dia. distance; senses
(2.5 x 2.5 cm) wafers and small
F: 7.2±1.0 mm difference in
(2.5 x 2.5 cm) height
E32-L24L H: 4±2 mm --- H: 0.015-mm dia. Limited
(2.5 x 2.5 cm) A: 0.015-mm dia. reflective, long
A: 4±2 mm F: 0.015-mm dia. distance,
(2.5 x 2.5 cm) side-view;
F: 4±2 mm senses wafers
(2.5 x 2.5 cm) and small
difference in
height
*Standard object: opaque
**Not trimmable

8
E3X E3X
Fine Through-beam
Model Appearance Sensing distance (standard object)* Min. sensing object Features
(opaque objects)
E32-T22S H: 1,000 mm (1.7-mm dia. min.) H: 0.5-mm dia. General purpose
T: 650 mm (1.7-mm dia. min.) T: 0.4-mm dia.
1.7 mm dia.

E32-T24S 3.5 x 3 mm dia.


H: 700 mm (1.7-mm dia. min.) H: 0.5-mm dia. Side-view
T: 450 mm (1.7-mm dia. min.) T: 0.4-mm dia.

E32-T84S H: 700 mm (1.7-mm dia. min.) H: 0.4-mm dia. Sensing the wafers
in cassettes (Fine,
long beam sensor
resisting 200°C)

*Use the E32-T22S and E32-T24S in combination with the E3X-H11, E3X-T11, or E3X-T21 Amplifier for stable wafer sensing.
Slot Sensors
Model Appearance Sensing distance (standard object)* Min. sensing object Features
(opaque objects)
E32-G14 10 mm (slot width) (4-mm dia. min.) T: 0.7-mm dia. Slot through-beam;
H: 1.0-mm dia. no optical axis
A: 0.5-mm dia. adjustment required
F: 0.6-mm dia.
V: 0.6-mm dia.
*Standard object: opaque
Liquid Level Fiber Unit
Liquid Contact Model
Model Appearance Standard Sensing object Repeat Applicable
sensing object angle range frequency Amplifier Unit
(see note)
E32-D82F1 Pure water at a ±10° max. 0.5 mm max. E3X-NT/NM
temperature of E3X-NV
E32-D82F2 25°C. E3X-H
Note: When using the E32-D82F1 or E82-D82F2 with the E3X-A, cut the plastic fiber part to 0.5 m, otherwise the energy of the light received
by the E3X-A will be insufficient.
Pipe Mounting Model
Model Appearance Standard sensing object Repeat frequency Applicable Amplifier Unit
E32-L25T Liquid (Non-transparent liquids 1 mm max. E3X-NT/NM
may not be sensed) E3X-A/H

9
E3X E3X
High-precision Screen Sensors
Model Appearance Slit width Sensing distance Min. sensing object*
(H: E3X-H11; A: E3X-Ajj; (horizontal beam)
F: E3X-Fjj; V: E3X-VGjj)
E32-T16P Not used H: 600 mm H: 1.3-mm dia. (1.1-mm dia.)
A: 300 mm A: 2.0-mm dia. (0.9-mm dia.)
0.5 mm wide H: 100 mm H: 1.3-mm dia. (0.4-mm dia.)
A: 50 mm A: 2.0-mm dia. (0.7-mm dia.)
1.0 mm wide H: 200 mm H: 1.3-mm dia. (0.6-mm dia.)
A: 100 mm A: 2.0-mm dia. (0.8-mm dia.)
E32-T16 Not used H: 1,500 mm H: 6.0-mm dia.
A: 750 mm A: 6.0-mm dia.
F: 330 mm F: 7.0-mm dia.
V: 150 mm V: 7.0 mm dia.
0.5 mm wide H: 900 mm H: 5.0-mm dia.
A: 450 mm A: 5.0-mm dia.
F: 120 mm F: 7.0-mm dia.
V: 20 mm V: 7.0-mm dia.
1.0 mm wide H: 1,200 mm H: 6.0-mm dia.
A: 600 mm A: 6.0-mm dia.
F: 250 mm F: 7.0-mm dia.
V: 60 mm V: 7.0-mm dia.
* Values not in parentheses represent sensing objects within the 11-mm sensing area and values in parentheses represent sensing objects in
the center of the E32-T16P sensing area. The diameters of sensing objects in the above table represent sensing object sizes, on condition
that the objects are not moving.

Sensing Direction

Sensing
object

Specifications
Amplifier Units
Indicator Light indicator (red), Stability indicator (green)
Sensitivity adjuster 8 turns with indicator (except E3X-Tjj)
Circuit protection Reverse polarity, Output short-circuit
Ambient temperature Operating:–25°C to 55°C (with no icing)
Storage: –40°C to 70°C
Ambient humidity 35% to 85% (with no condensation)
Ambient illumination Sunlight: 10,000 ȏx max.; Incandescent lamp: 3,000 ȏx max.
Insulation resistance 20 MW min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Enclosure rating IEC IP66 (with protective cover in place) (see note)
Material Case: Heat-resistive ABS; Cover: Polycarbonate
Connection method Cord-drawing method
Weight (with 2-m cord) Approx. 100 g
Note: The enclosure rating is IP50 without the protection cover.

10
E3X E3X
Fiber Unit
Through-beam (Separate) Sensors
Model Ambient temperature Ambient humidity Permissible Material Enclosure rating
bending radius
E32-T11L O e a g –40°C
Operating: 0 C to
o 70°C
0C Operating:
g 35% to 25 mm min. Black polyethylene IEC IP67
( ith no iicing)
(with i ) 85%
E32-T12L
E32-T21L
E32-T22L
E32-TC200
E32-TC200B
E32-TC200B4
E32-T22
E32-TC200E
E32-TC200F
E32-TC200F4
E32-TC200A
E32-T11 4 mm min. Vinyl chloride
E32-T21
E32-TC200C 25 mm min. Black polyethylene
E32-TC200D
E32-TC200D4
E32-T14L
E32-T24
E32-T14
E32-T17L
E32-T12F Operating: –30°C to 70°C 40 mm min. Teflon-covered
(with no icing) black polyethylene
E32-M21 Operating: –40°C to 70°C 25 mm min. Black polyethylene
(with no icing)
E32-T51 Operating: –40°C to 35 mm min. Fluoride resin
150°C* (with no icing)
E32-T61 Operating: –40°C to 25 mm min. SUS
300°C (with no icing)
*When used continuously between –40°C and 130°C.

11
E3X E3X
Reflective Sensors
Model Differential travel Ambient Ambient Permissible Material Enclosure rating
temperature humidity bending radius
E32-D11L 20% of max. of O e a g –40°C
Operating: 0C Operating:
g 25 mm min. Black IEC IP67
sensing
i distance
di t to 70°C (with
( i h no 35% to
t 85% polyethylene
l th l
E32-D12 (Adjustable in a icing)
E32-D21L range of 0% to
E32-D22L 20% when the
E3X-H11 is used
used.))
E32-DC200
E32-DC200B
E32-DC200B4
E32-DC200E
E32-DC200F
E32-DC200F4
E32-D11 4 mm min. Vinyl chloride
E32-D21
E32-DC200C 25 mm min. Black
E32-DC200D polyethylene
l th l
E32-DC200D4
E32-DC9G
E32-DC9G4
E32-D33
E32-CC200
E32-D32
E32-D32L
E32-D14L
E32-D24
E32-D12F Operating: –30°C 40 mm min. Teflon-covered
to 70°C (with no black
icing) polyethylene*
E32-D51 Operating: –40°C 35 mm min. Fluoride resin
to 150°C (with no
icing)**
E32-D61 Operating: –40°C 25 mm min. SUS
to 300°C (with no
icing)
E32-D73 Operating: –40°C
to 400°C (with no
icing)
E32-R21 Operating: –40°C Black
E39-R3 to 70°C (with no polyethylene
icing)
E32-R16 Operating: –25°C IEC IP66
E39-R1 to 55°C (with no
icing)
E32-L25 Operating: –40°C IEC IP50
to 70°C (with no
E32-L25A icing)
E32-L25L*** Operating: –40°C 10 mm min. Reinforced
to 105°C (with no (average at 10% polyethylene
icing) decrease of
E32-L24L*** sensing
distance)
*Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
**When used continuously between –40°C and 130°C.
***Beam size: 2 mm dia.

12
E3X E3X
Fine Through-beam Sensors
Model Beam size Differencial Horizontal Ambient Ambient Permissible Material Enclosure
travel positioning temperature humidity bending rating
accuracy radius*
E32-T22S 13 mm dia. (at --- --- Operating: Operating: 10 mm min. Reinforced IEC IP67
a distance of –40°C to 70°C 35% to 85% laminated
E32-T24S 200 mm) (with no icing) vinyl chloride
E32-T84S Operating: 25 mm min. SUS
–40°C to
200°C (with no
icing)
*Average at 30% of sensing distance
Slot Sensors
Model Ambient temperature Ambient humidity Permissible Material Enclosure rating
bending radius
E32-G14 Operating: –40°C to 70°C Operating: 35% to 25 mm min. Black polyethylene IEC IP67
(with no icing) 85%

Liquid Contact Model


Model Differencial Ambient Ambient Ambient Permissible Material Enclosure
travel temperature humidity pressure bending radius* rating
(average at 10%
of sensing
distance)
E32-D82F1 3.0 mm max. Teflon part within Operating: –50 kpa 40 mm min. (plastic Sensing head: IEC IP68**
1.5 m of fiber tip: 35% to 85% (–0.49 kgf/cm2) fiber: 25 mm min.) Teflon* (PFA)
–40°C to 200°C to 500 kpa Bending-prohibited Fiber sheath:
(with no icing)
(4.9 kgf/cm2) part: Black
Parts other than E32-D82F1: y y
polyethylene
above:
b Withi 150 mm off
Within
E32-D82F2 fiber tip Connector:
–40°C to 85°C
E32-D82F2: Nickel-coated
(with no icing)
Within 350 mm of brass
fiber tip
*The teflon part located 10 cm underwater must not generate air bubbles when air is injected into the teflon part with a pressure of 98 kpa
(1 kgf/cm2).
**Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
Pipe Mounting Model
Model Suitable pipe Pipe material Ambient Ambient Permissible Material Enclosure
temperature humidity bending rating
radius
E32-L25T Transparent pipes FEP Operating: Operating: 10 mm min. Sensing head: IEC IP50
with an outer transparent –40°C to 70°C 35% to 85% Polycarbonate
diameter of 8 to pipes or (with no icing)
10 mm and an Fiber:
equivalent
inner diameter of Polyethylene-
6 to 8 mm covered plastic

High-precision Screen Sensors


Model Ambient temperature Ambient humidity Permissible Material Enclosure rating
bending radius
E32-T16P Operating: –40°C to 70°C Operating: 35% to R10 mm min. Sensing head: IEC IP50
(with no icing) 85% Heat-resistive ABS
Fiber sheath:
Vinyl chloride
E32-T16 25 mm min. Sensing head: IEC IP67
Heat-resistive ABS
Sensing surface:
PMMA
Fiber sheath:
Black polyethylene

13
E3X E3X
Attachments
Name Small Spot Lens Unit Long Distance Lens Unit
Applications Sensing over Increasing sensing distance
0.5-mm-dia. spots
Model E39-F3A E39-F1
Appearance Reflective Through-beam
(separate)

Applicable fibers E32-D32 E32-T11L E32-TC200 E32-T11 E32-TC200C


E32-T61
With Sensing distance 20 mm 1,200 mm 2,000 mm 1,300 mm 800 mm
E3X-Tjj Standard object White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
With Sensing distance 20 mm 2,000 mm 3,000 mm 2,000 mm 1,600 mm
E3X-H11 Standard object White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
With Sensing distance 20 mm 1,000 mm 1,500 mm 1,000 mm 800 mm
E3X-Ajj Standard object White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
With Sensing distance 16 mm 550 mm 670 mm* 400 mm 350 mm
E3X-Fjj Standard object White paper 2.5 x 2.5 cm Opaque objects: 4-mm dia. min.
With Sensing distance --- 120 mm 190 mm** 120 mm 100 mm
E3X-VGjj Standard object --- Opaque objects: 4-mm dia. min.
Directivity --- 5° to 40°
Differential travel 20% of sensing distance ---
Ambient temperature Operating: –40°C to Operating: –40°C to 200°C (Do not exceed the operating
70°C temperature of the fiber.)
Material Shaft Aluminum Brass
Lens Optical glass
Base ---
Reflector ---
*E32-T6: 450 mm.
**E32-T6: 130 mm.

Name Side-view Unit


Applications Changing the sensing direction at °90
Model E39-F2
Appearance Through-beam
(separate)

Applicable fibers E32-T11L E32-TC200 E32-T61/11 E32-TC200C


With Sensing distance 250 mm 250 mm 200 mm 100 mm
E3X-Tjj Standard object Opaque objects: 3-mm dia. min.
With Sensing distance 400 mm 500 mm 400 mm 200 mm
E3X-H11 Standard object Opaque objects: 3-mm dia. min.
With Sensing distance 200 mm 250 mm 200 mm 100 mm
E3X-Ajj Standard object Opaque objects: 3-mm dia. min.
With Sensing distance 60 mm 100 mm 60 mm 30 mm
E3X-Fjj Standard object Opaque objects: 3-mm dia. min.
With Sensing distance 10 mm 19 mm 10 mm 6 mm
E3X-VGjj Standard object Opaque objects: Opaque objects: 3-mm dia. min.
4-mm dia. min.
Directivity 20° to 60°
Differential travel ---
Ambient temperature Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.)
Material Shaft Brass
Lens Optical glass
Base ---
Reflector ---

14
E3X E3X

Name Lens-equipped Reflective Unit


Applications Converting through-beam sensors to reflective sensors
Model E39-F3
Appearance
Reflective

Applicable fibers E32-T11L E32-TC200 E32-T61


With Sensing distance White paper 55 to 150* mm (20 x 20 cm) 85 to 100 mm (20 x 20* cm)
E3X-Tjj (standard object) Black paper --- 15 to 17*mm (20 x 20 cm) 16 to 18*mm (20 x
20 cm)
With Sensing distance White paper 10 to 300 mm (20 x 20 cm) 35 to 180 mm (20 x 20 cm)
E3X-H11 (standard object) Black paper --- 5 to 120 mm (20 x 20 cm) 5 to 80 mm (20 x
20 cm)
With Sensing distance White paper 10 to 150 mm (20 x 20 cm) 35 to 90 mm (10 x 10 cm)
E3X-Ajj (standard object) Black paper --- 5 to 60 mm (10 x 10 cm) 5 to 40 mm (10 x
10 cm)
With Sensing distance White paper 10 to 65 mm (10 x 10 cm) 20 to 40 mm (5 x 5 cm) 20 to 35 mm (5 x 5 cm)
E3X-Fjj (standard object) Black paper --- 10 to 20 mm (5 x 5 cm) ---
With Sensing distance White paper --- 10 to 15 mm (2.5 x 2.5 cm) ---
E3X-VGjj (standard object) Black paper ---
Directivity ---
Differential travel 20% of sensing distance
Ambient temperature Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.)
Material Shaft Brass
Lens Optical glass
Base Aluminum
Reflector ---
*These values are possible when the angle of the E39-F3 is smallest (parallel).

15
E3X E3X

Name Lens-equipped Reflective Unit Side-view Reflective


Unit
Applications Converting through-beam sensors to reflective Converting
sensors through-beam to
reflective sensor
Model E39-F3 E39-F5
Appearance Reflective
Reflective

Applicable fibers E32-T11 E32-TC200C E32-TC200A


With Sensing distance White paper 90 to 100* mm (20 x 85 to 100* mm (20 x 5 to 30* mm (10 x 10 cm)
(standard object) 20 cm) 20 cm)
E3X-Tjj Black paper --- 6 to 9* mm (10 x 10 cm)
With Sensing distance White paper 35 to 180 mm (20 x 20 cm) 60 mm (10 x 10 cm)
E3X-H11 (standard object) Black paper 5 to 70 mm (20 x 20 cm) 10 to 60 mm (20 x 20 cm) 5 to 20 mm (10 x 10 cm)
With Sensing distance White paper 35 to 90 mm (10 x 10 cm) 30 mm (5 x 5 cm)
E3X-Ajj (standard object) Black paper 5 to 35 mm (10 x 10 cm) 10 to 30 mm (10 x 10 cm) 5 to 10 mm (5 x 5 cm)
With Sensing distance White paper 20 to 40 mm (5 x 5 cm) 20 to 35 mm (5 x 5 cm) 13 mm (2.5 x 2.5 cm)
E3X-Fjj (standard object) Black paper --- ---
With Sensing distance White paper --- ---
E3X-VGjj (standard object) Black paper ---
Directivity ---
Differential travel 20% of sensing distance
Ambient temperature Operating: –40°C to 200°C (Do not exceed the Operating: –40°C to
operating temperature of the fiber.) 70°C
Material Shaft Brass ---
Lens Optical glass ---
Base Aluminum Brass
Reflector --- Stainless
*These values are possible when the angle of the E39-F3 is smallest (parallel).

Beam Spot Characteristics


E39-F3A
ȏ d O: Spot diameter
(mm)
Fiber ȏ: Insertion distance 1.5
E32-D32 d: Focal length
Focal length d (mm)

1.0

0.8
0.5

Insertion distance ȏ (mm)

16
E3X E3X
Spiral Tubes
Model E39-F32A5 E39-F32A E39-F32B5 E39-F32B E39-F32C5 E39-F32C E39-F32D5 E39-F32D
Appearance L

End cap Tube Head connector

Length (L) 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm
Applicable fiber E32-DC200E E32-TC200E E32-TC200 E32-DC200
E32-DC200F(4) E32-TC200F(4) E32-TC200B(4) E32-DC200B(4)
E32-D21 E32-T21 E32-T11 E32-CC200
E32-T21L E32-T51 E32-D11
E32-T11L E32-D51
E32-D11L
Ambient temperature Operating: –40°C to 150°C (Do not exceed the operating temperature of the fiber)
Ambient humidity Operating: 35% to 85%
Permissible bending R: 30 mm min.
radius
Tensile strength Between head connector and end cap with tube: 15 kgf $ cm max. (1.5 N $ m)
Tube: 20 kgf $ cm max. (2 N $ m)
Compression load Tube: 3 kg max. (29.4 N)

Accessories
Name Fiber Cutter Fine-fiber Attachment Fiber Connector Sleeve Bender
Model E39-F4 E39-F9 E39-F10 E39-F11
Appearance

Features Used to cut fibers to Used when inserting fine Used to connect fibers Used to bend fiber
desired lengths fibers into the amp when broken sleeves
Applicable fiber All models equipped with E32-DC200E, -TC200E E32-DC200, -TC200 E32-TC200B(4)
trimmable fibers E32-DC200F(4), E32-DC200B(4), E32-TC200D(4)
-TC200F(4) -TC200B(4) E32-DC200F(4),
E32-D21, -D21L, -D22L E32-TC200A -TC200F(4)
E32-T21, -T21L, -T22L E32-T14, -G14 E32-DC9G(4)
E32-D32, -T22 E32-D11L, -T11L, -T12L
E32-D24. -T24 E32-D14L, -T14L
E32-D33 E32-T17L
E32-R21

17
E3X E3X

Engineering Data
Excess Gain Ratio
E3X-Tjj
E32-TC200 E32-T11L E32-T11L + E39-F1

Sensing distance Sensing distance Sensing distance


Excess gain ratio

Excess gain ratio


Excess gain ratio

Sensing distance (mm) Sensing distance (mm) Sensing distance (m)

E32-T11L + E39-F2 E32-T11L + E39-F3 E32-T21L


(When the angle of the E39-F3 is at
its minimum (parallel).)
Sensing distance Sensing Sensing distance
object
Excess gain ratio

Excess gain ratio


Excess gain ratio

Sensing
distance

Sensing distance (mm) Sensing distance (mm) Sensing distance (mm)

E32-T14L E32-T17L E32-T16

Sensing distance Sensing distance Sensing distance


Excess gain ratio

Excess gain ratio


Excess gain ratio

Sensing distance (mm) Sensing distance (m) Sensing distance (m)

18
E3X E3X
E32-DC200 E32-D11L E32-D21L

Sensing distance Sensing distance Sensing distance

Sensing Sensing Sensing


object object object
Excess gain ratio

Excess gain ratio


Excess gain ratio
Sensing distance (mm) Sensing distance (mm) Sensing distance (mm)

E3X-H11
E32-TC200 E32-TC200 + E39-F1 E32-T11L
Sensing distance Sensing distance Sensing distance
Excess gain ratio

Excess gain ratio


Excess gain ratio

Sensing distance (mm) Sensing distance (m) Sensing distance (mm)


E32-T11L + E39-F1 E32-T11L + E39-F2 E32-T11L + E39-F3

Sensing distance Sensing distance Sensing


object
Excess gain ratio

Excess gain ratio

Sensing distance
Excess gain ratio

Sensing distance (m) Sensing distance (mm) Sensing distance (mm)

19
E3X E3X
E32-T21L E32-T14L E32-T17L
Sensing distance Sensing distance Sensing distance
Excess gain ratio

Excess gain ratio


Excess gain ratio
Sensing distance (mm) Sensing distance (mm) Sensing distance (m)
E32-T16 E32-T22S E32-T24S
Sensing distance Sensing distance Sensing distance
Excess gain ratio

Excess gain ratio

Excess gain ratio

Sensing distance (m) Sensing distance (mm) Sensing distance (mm)

E32-DC200 E32-D11L E32-D21L

Sensing distance Sensing distance Sensing distance

Sensing Sensing
Excess gain ratio

Excess gain ratio

Excess gain ratio

object object

Sensing distance (mm) Sensing distance (mm) Sensing distance (mm)

20
E3X E3X
E32-T84S

Sensing distance
Excess gain ratio

Sensing distance (mm)

E3X-Ajj/-Fjj/-VGjj
E32-T11L, E32-T12L E32-T11L + E39-F1 E32-T11L + E39-F2
Sensing distance Sensing distance Sensing distance
Excess gain ratio

Excess gain ratio


Excess gain ratio

E3X-Aj
E3X-Aj
E3X-Aj

E3X-Fj E3X-Fj E3X-Fj

Operating level E3X-VGj Operating


Operating level level
E3X-VGj E3X-VGj

Sensing distance (mm) Sensing distance (cm) Sensing distance (mm)

E32-T11L + E39-F3 E32-T21L, E32-T22L E32-T14L

Sensing object Sensing distance Sensing distance


Excess gain ratio

Excess gain ratio


Excess gain ratio

Sensing distance

E3X-Aj
E3X-Aj E3X-Aj

E3X-Fj E3X-Fj
E3X-Fj

Operating level Operating level Operating level


E3X-VGj E3X-VGj

Sensing distance (mm) Sensing distance (mm) Sensing distance (mm)

21
E3X E3X
E32-T17L E32-T12F E32-D11L
Sensing distance Sensing distance Sensing distance

Sensing object
Excess gain ratio

Excess gain ratio


Excess gain ratio
E3X-Aj
E3X-Aj E3X-Aj

E3X-Fj E3X-Fj
E3X-Fj

Operating level Operating level


E3X-VGj Operating level
E3X-VGj E3X-VGj

Sensing distance (m) Sensing distance (cm) Sensing distance (mm)

E32-D21L, E32-D22L E32-D14L E32-D12F


Sensing distance Sensing distance Sensing distance

Sensing object Sensing object


Sensing
Excess gain ratio

Excess gain ratio


object
Excess gain ratio

E3X-Aj E3X-Aj E3X-Aj

E3X-Fj E3X-Fj
E3X-Fj

Operating level Operating level Operating level


E3X-VGj E3X-VGj E3X-VGj

Sensing distance (mm) Sensing distance (mm) Sensing distance (mm)

Operating Range
E3X-Tjj
E32-DC200 E32-D11L
Operating position Y (mm)

Operating position Y (mm)

X X

Y Y

Set distance Set distance


X (mm) X (mm)

E32-D21L
Operating position Y (mm)

X
Y

Set distance
X (mm)

22
E3X E3X
E3X-H11
E32-T11L + E39-F3 E32-DC200 E32-D11L
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


Set distance Set distance
X (mm) Set distance X (mm)
X (mm)

Sensing object Sensing object Sensing object

E32-D12 E32-D21L E32-DC200E


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


Set distance Set distance Set distance
X (mm) X (mm) X (mm)

Sensing object Sensing object Sensing object

E32-D21 E32-D11 E32-CC200


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

Sensing object Sensing object Sensing object

E32-D32 E32-D32L E32-D33


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set distance Set distance X (mm)


X (mm) Set distance
X (mm)

E32-D51 E32-L25L E32-T84S


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set distance Set distance Set distance


X (mm) X (mm) X (mm)
Operating
position Y Sensing object

Sensing object Set distance X

Sensing
object Set distance X

23
E3X E3X
E3X-Ajj/-Fjj/-VGjj
E32-T11L + E39-F3 E32-DC200 E32-D11L
E3X-VGj
E3X-Fj
Operating position Y (mm)

E3X-Aj

Operating position Y (mm)

Operating position Y (mm)


E3X-Aj E3X-Aj

E3X-Fj E3X-Fj

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

Sensing object Sensing object Sensing object

Note: With E3X-A: Adjust the angle of


E39-F3 so that the sensor can
sense an object at a distance of
90 mm. (For E3X-F: 50 mm)

E32-D12 E32-D21L + E32-D22L E32-DC200E


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-Aj
E3X-VGj Amplifier Amplifier E3X-Aj
E3X-Fj E3X-Aj

E3X-Fj Amplifier

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

Sensing object Sensing object Sensing object

E32-D21 E32-D11 E32-D33


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

E3X-VGj E3X-Aj
E3X-Fj E3X-Aj
E3X-Aj

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

Sensing object Sensing object

E32-CC200 E32-D32L E32-D14L

E3X-VGj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

E3X-Fj E3X-Aj E3X-VGj Amplifier E3X-Aj


E3X-Fj E3X-Aj Amplifier
Amplifier
E3X-Fj

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

Sensing object

24
E3X E3X
E32-D24 E32-D12F E32-D51

E3X-Aj
E3X-VGj E3X-Fj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-Aj
E3X-Fj E3X-Aj
E3X-Fj

Set distance Set Set distance


X (mm) distance X X (mm)
(mm)

Sensing object Sensing object

E32-D61 E32-D73 E32-R16

E3X-Aj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-Fj
E3X-Aj
E3X-Fj E3X-Aj

Set distance X (mm) Set distance Set distance


X (mm) X (mm)

Sensing
object Sensing object Sensing object

E32-L25L
Operating position Y (mm)

Set distance
X (mm)
Operating
position Y Sensing object
Sensing object Set distance X

Set distance X

25
E3X E3X

Parallel Operating Range (Typical)


E3X-Tjj
E32-TC200 E32-T11L
Parallel operating range Y (mm)

Parallel operating range Y (mm)


X X
Y Y

Set distance Set distance


X (mm) X (mm)

E32-T11L +E39-F1 E32-T11L + E39-F2


Parallel operating range Y (cm)

Parallel operating range Y (mm)


X X
Y Y

Set distance X (m) Set


distance
X (mm)

E32-T21L E32-T14L
Parallel operating range Y (mm)
Parallel operating range Y (mm)

X X
Y Y

Set Set distance


distance X (mm)
X (mm)

E32-T17L E32-T12F
Parallel operating range Y (cm)

Parallel operating range Y (cm)

X X
Y Y

Set distance Set


X (m) distance
X (m)

26
E3X E3X
E3X-H11
E32-TC200 E32-TC200 + E39-F2 E32-T11L
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


Set distance Set distance
X (mm) Set distance
X (mm) X (mm)

E32-T11L + E39-F1 E32-T11L + E39-F2 E32-T21L


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


Set distance
Set distance Set distance
X (mm)
X (mm) X (mm)

E32-T21L E32-T22 E32-T11


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set Set distance Set distance


distance X (mm) X (mm)
X (mm)

E32-T21 E32-T14L E32-T24


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set distance Set distance


X (mm) Set distance X (mm)
X (mm)

E32-T14 E32-T17L E32-T12F


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

Set distance
X (mm) Set distance Set distance
X (mm) X (mm)

27
E3X E3X
E32-M21 E32-T51 E32-T61
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


Set distance Set distance Set
X (mm) X (mm) distance X
(mm)

E32-T22S E32-T24S
Operating position Y (mm)

Operating position Y (mm)

Set distance Set distance


X (mm) X (mm)

E3X-Ajj/-Fjj/-VGjj
E32-TC200 E32-TC200 + E39-F2 E32-T11L/-T12L

E3X-Aj
Operating position Y (mm)

Operating position Y (mm)

E3X-Aj Operating position Y (mm)


E3X-VGj E3X-VGj E3X-Aj

E3X-Fj E3X-Fj

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

E32-T11L + E39-F1 E32-T11L + E39-F2 E32-T21L/-T22L


E3X-Aj E3X-Aj
E3X-VGj
E3X-Aj
Operating position Y (mm)

E3X-VGj
Operating position Y (mm)

Operating position Y (mm)

E3X-VGj

E3X-Fj E3X-Fj E3X-Fj

Set Set distance Set distance


distance X (mm) X (mm)
X (mm)

28
E3X E3X
E32-TC200E E32-T11 E32-T21
E3X-VGj E3X-Aj E3X-Aj
E3X-VGj E3X-Aj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-Fj
E3X-Fj E3X-Fj

Set Set distance Set distance


distance X X (mm) X (mm)
(mm)

E32-T14L E32-T24 E32-T14

E3X-VGj E3X-Aj E3X-Fj E3X-Aj


E3X-VGj E3X-Aj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-Fj

Set distance Set distance


Set distance X (mm) X (mm)
X (mm)

E32-T17L E32-T12F E32-M21

E3X-Aj E3X-Aj E3X-Aj


Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)


E3X-VGj E3X-VGj E3X-F21

E3X-Fj E3X-Fj

Set distance Set distance Set


X (mm) X (mm) distance
X (mm)

E32-T51 E32-T61 E32-T61 + E39-F1


E3X-Aj E3X-Aj E3X-Aj
Operating position Y (mm)

Operating position Y (mm)

Operating position Y (mm)

E3X-Fj

Set distance Set distance Set distance


X (mm) X (mm) X (mm)

E32-T22S E32-T24S
E3X-Aj
E3X-Aj
E3X-VGj
Operating position Y (mm)

Operating position Y (mm)

E3X-VGj
E3X-Fj
E3X-Fj

Set distance X (mm) Set distance X (mm)

29
E3X E3X
Number of Turns of Sensitivity
Adjuster and Sensing Distance (Typical)
E3X-H/E32-D11L E3X-A, -F/E32-D11L
Sensing Object: White Paper of 5 x 5 cm Sensing Object: White Paper of 10 x 10 cm
with E3X-A and 5 x 5 cm with E3X-F
Sensing distance (mm)

Sensing distance (mm)


E3X-Aj

E3X-Fj

Sensitivity adjuster Sensitivity adjuster

Color Sensing (Typical)


Green Light Source E3X-VGj /E32-D11L
The following graph shows the relationship between colors and the
number of turns of the sensitivity adjustor when the E32-D11L is in
operation with the sensing distance adjusted to 5 mm.

Munsell chroma (MC)


White CM484
Yellow CM124 5 mm
Amber CM 78
10°
Yellow green CM157
Orange CM 85 Color paper
(2.5 x 2.5 cm)
Aqua CM263
Red CM 6
Purple CM379
Magenta CM431
Blue CM336
Green CM241
Black CM489

Number of turns

30
E3X E3X

Nomenclature
E3X-Tjj E3X-H11

Stable Operation Light Reception Stable Operation Light Reception


Indicator (Green Indicator) Indicator (Red Indicator (Green Indicator) Indicator (Red
Tuning Indicator (Two Indicator) Indicator)
Sensitivity Indicator
Colors: red/green indicator) The position of the indicator
Tuning Button can be checked.
8-turn Sensitivity Adjuster

Mode Setting Selector Hysteresis Adjuster

Timer Switch Timer Switch


ON: Timer function ON: Timer function
is ON. is ON.
Operation Mode Selector Mode Selector
OFF: Timer function OFF: Timer function
L-ON: Output transistor is ON SET: The light source
is OFF. is OFF.
when light is received. flashes. Set to this
D-ON: Output transistor is ON mode to adjust the
when light is not received. light axis.
Light Reception L-ON: Output transistor is ON Light Reception
Monitoring Terminal when light is received. Monitoring Terminal
(see note) D-ON: Output transistor is ON Monitoring is used
Monitoring is used when light is not re- with the E39-VX Beam
with the E39-VX ceived. Checker
Beam Checker

Note: The light reception monitoring terminal is not available with the E3X-T11.

E3X-A11/-A41 E3X-A21/-A51
E3X-VG11 E3X-F21/-F51
E3X-VG21

Light Reception Stable Operation Light Reception


Stable Operation Indicator (Red In-
Indicator (Green Indicator (Green Indicator) Indicator (Red
dicator) Indicator)
Indicator) Sensitivity Indicator
Sensitivity Indicator
Sensitivity adjustment
can be checked visually.
8-turn Sensitivity 8-turn Sensitivity
Adjuster Adjuster
Timer Adjuster

Timer Switch
ON: Timer function
is ON.
OFF: Timer function
is OFF.
Mode Selector Light Reception
SET: The light source Light Reception Mode Selector
Monitoring Terminal SET: The light source Monitoring Terminal
flashes. Set to this Monitoring is used
mode to adjust the Monitoring is used flashes. Set to this
with the E39-VX mode to adjust the with the E39-VX Beam
light axis. Checker
L-ON: Output transistor is ON Beam Checker light axis.
when light is received. L-ON: Output transistor is ON
D-ON: Output transistor is ON when light is received.
when light is not re- D-ON: Output transistor is ON
ceived. when light is not re-
ceived.
Note: Set the mode selector to L-ON or D-ON after the
light axis is adjusted.

31
E3X E3X

Operation
Output Circuits
Type Model Mode Output Output circuit
switch transistor
NPN E3X-T21 Light ON ON when light
Light Tuning (red/
is received. (red) Stability
green) Brown
(green)
Load
Black
Load
Main Orange Control output
circuit ZD Self-diagnostis
Self diagnostis
ZD t t
output
Dark ON ON when light Blue
is not received.
Remote tuning
input
Pink
Remote bank
Purple selection input

ZD : VZ = 39 V

E3X-T11 Light ON ON when light Brown


Light Stability
E3x-H11 is received. (red) (green)
E3X-A11 Load
E3X-VG11 Black
Main
circuit 100 mA max.
ZD
Dark ON ON when light Blue
is not received.
ZD : VZ = 39 V

E3X-A21 Light ON ON when light


E3X-VG21 is received. Light Stability Brown
(red) (green)
E3X-F21 Load
(Relay)

Black Load
Main (Relay)
circuit ZD Control
output
g
Orange Self-diagno-
sis output
Dark ON ON when light ZD
External-
is not received. check input
Pink
10 K

Blue
ZD : VZ = 39 V

PNP E3X-A41 Light ON ON when light Brown


Light Stability
is received. (red) (green)
ZD
Black
Main
circuit 100 mA max.
Dark ON ON when light
is not received. Load
Blue
ZD : VZ = 39 V

E3X-A51 Light ON ON when light


Brown
E3X-F51 is received.

Light Stability 10 K External-check


(red) (green) input
ZD Pink
Self-diagno-
sis output
Orange
ZD Control
Dark ON ON when light Main output
circuit Load
is not received. Black (Relay)
Load
(Relay)

Blue
ZD : VZ = 39 V

32
E3X E3X

Timing Charts
Type Model Mode Output Timing chart
switch transistor
NPN E3X-T21 Light ON ON when light Light received
Light not received
is received. T
Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate (Between brown and black)
(relay) Release

Dark ON ON when light Light received


Light not received
is not received.
Light indicator ON
(Red) OFF
T
Output ON
transistor OFF
Load Operate
(relay) Release (Between brown and black)

E3X-T11 Light ON ON when light Light received


Light not received
E3X-H11 is received.
E3X-A11 Light indicator ON
(Red) OFF
E3X-VG11
Output ON
transistor OFF
Load Operate (Between brown and black)
(relay) Release

Dark ON ON when light Light received


Light not received
is not received.
Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate (Between brown and black)
(relay) Release

E3X-A21 Light ON ON when light Light received


Light not received
E3X-VG21 is received. T
E3X-F21 Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate (Between brown and black)
(relay) Release

Dark ON ON when light Light received


Light not received
is not received.
Light indicator ON
(Red) OFF
T
Output ON
transistor OFF
Load Operate (Between brown and black)
(relay) Release

33
E3X E3X

Type Model Mode Output Timing chart


switch transistor
PNP E3X-A41 Light ON ON when light Light received
Light not received
is received.
Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate (Between blue and black)
(relay) Release

Dark ON ON when light Light received


Light not received
is not received.
Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate (Between blue and black)
(relay) Release

E3X-A51 Light ON ON when light Light received


Light not received
E3X-F51 is received. T
Light indicator ON
(Red) OFF
Output ON
transistor OFF
Load Operate
(relay) Release (Between blue and black)

Dark ON ON when light Light received


Light not received
is not received.
Light indicator ON
(Red) OFF
T
Output ON
transistor OFF
Load Operate (Between blue and black)
(relay) Release

34
E3X E3X

Sensitivity Adjustment
E3X-Tjj
1. Locate the sensor head in the sensing range of the E3X.
2. Set the mode selector to TUNING.
3. Locate the object at the sensing position and press the tuning
button.
Through-beam Model Reflective Model Reflective Model

Mark

Light is not
received.
Base

The tuning indicator (red) is lit.


The built-in buzzer beeps once.

4. Move the object and press the tuning button.


Through-beam Model Reflective Model Reflective Model

Mark

Light is received..

Base

If tuning is OK: The tuning indicator turns green.


The built-in buzzer beeps once.
If tuning is NG: The tuning indicator (red) is still lit.
The built-in buzzer beeps 3 times.
Change the position of the object and the sensing distance that have
been set and repeat from the beginning.

5. Set the mode setting selector to RUN to complete the


sensitivity setting on the E3X.
The tuning indicator (green) is OFF.
6. Select the logical output required with the operation mode
selector.
Maximum Sensitivity Setting
1. Set the mode setting selector to TUNING.
2. Press the tuning button, at which time the object may or may
not be located at the sensing position.
The tuning indicator (red) is lit.
The built-in buzzer beeps once.
3. Set the mode setting selector to RUN to complete the
maximum sensitivity setting on the E3X. It will take
approximately three seconds for the stable operation
indicator or light reception indicator to be lit. After the
maximum sensitivity setting is completed, the tuning indicator
will turn green and then it will be automatically turned OFF in
approximately three seconds. The maximum sensitivity of the
E3X can be automatically set regardless of the set distance or
light reception.
Note: The sensitivity of the E3X-T11 and E3X-T21 are set to max-
imum before shipping.

35
E3X E3X
E3X-H11/-Ajj/-Fjj/-VGjj
Using a sensing object, adjust Sensitivity Adjustor so that the indicators operate as described in the following table:

Sensing method Sensing Light Indicators


Through-beam Interrupted

Green: Light ON
With sensing object Red: Light OFF
Incident
Without sensing object Green: Light ON
Red: Light ON

Reflective Sensing Incident


With sensing object
Green: Light ON
Red: Light ON

Without sensing object


Interrupted

Green: Light ON
Red: Light OFF

Sensing of the Incident


difference in color or
shade Color that has a Green: Light ON
high reflection ratio Red: Light ON

Interrupted

Color that has a Green: Light ON


low reflection ratio Red: Light OFF

Retroreflective Interrupted

Green: Light ON
With sensing Reflector Red: Light OFF
object

Incident

Green: Light ON
Without sensing Reflector Red: Light ON
object

Note: 1. If the indicators operate as described in the table, the E3X can operate in stable condition within the rated temperature range.
2. Even when the green indicator is OFF, the E3X will operate stably if the operating temperature change since the initial settings is
within +10°C.

36
Light Axis Adjustment with Flashing Function
E3X-Tjj
This function enables the user to adjust with ease the light axis of the through-beam fiber with the light source flashing. All E3X models have this
function.

1. Set the mode setting selector to FLASH. 2. If the axis of the light emission fiber head and that of the
light reception fiber head do not agree with each other
and the amount of light reception becomes 90% of the
peak value or less, the flashing function of the E3X will
Mode Setting Selector work. The E3X retains the peak value when the mode
setting selector is set to FLASH and the axes of the
fiber heads are adjusted to agree with each other.

Fiber for light emission Fiber for light reception

Optical input

The peak of light reception


Lit in this range.
90% of the peak value

Angle of the head (θ)

Flashing Lit Flashing

E3X-Ajj/-Fjj/-VGjj
1. Set the mode selector to SET. 2. Adjust the light axis by moving the fiber with the light
flashing.
Improper Light Axis Proper Light Axis
Light ON with
Flashing no flushing
Light axis
adjusted
Mode Selector

3. Set the mode selector to L-ON or D-ON after the light axis
is adjusted.

1
37
E3X E3X

Self-diagnostic Function
With this function, the E3X checks changes in environmental condi- Displays
tions (especially a change in the ambient temperature) and
self-diagnoses the resistance against the changes. The result is
• Stable Operation Indicator: Changes in environmental
shown by the indicators or an output signal. conditions (changes in the ambient temperature, the operating
voltage, or the volume of dust) are checked and the resistance
Stable Operation Indicator Light Reception Indicator against them are self-diagnosed. The result is shown via the
(Green Indicator) (Red Indicator) indicator.
• Light Reception Indicator: The amount of light received is
indicated by this indicator.
Output
• The resistance against changes in environmental conditions is
indicated by the indicator and the result is output.

Amount of
light Operating level x 1.2
1.2
Operating level
1
Operating level x 0.8
0.8

ON
Control output
(L-ON) OFF
0.3 s min. 0.3 s min.
ON

ÍÍÍÍÍ
Self-diagnostic
output* OFF

ÈÈ ÍÍÍÍÍ
ÈÈÈÈ ÈÈÈ Red

ÈÈ ÉÉÉÉÉ
ÈÈÈÈ ÈÈÈ
Indicator Green Green Green

ÉÉÉÉÉ
Tip of the fiber connected
to the light source side in Flashing light ON Flashing
the SET mode

*If the self-diagnostic output is ON when the sensing object is


moving at low speed, use the E3X with an ON-delay timer circuit.

Remote Tuning/Remote Bank Function (E3X-T21)


Remote Tuning Function
Basically, the method of remote tuning is same as that of sensitivity adjustment. When the remote tuning function of the E3X is used, the E3X is
tuned with the remote tuning input signal instead of the tuning button which has to be pressed.
1. Set the mode selector to RUN.
2. The following signal conditions must be given as remote
tuning input conditions.
Brown +V

Black; control output


Orange; self-diagnostis
output
Purple; remote
bank selection
Pink

Blue 0 V

If no remote tuning is done, cut off the purple wire at its


source or connect the pink wire to the positive terminal
of the power supply.

2
38
E3X E3X

Power supply
ON
OFF
Remote tuning input Sensitivity setting T1 T2 T1
H
L
T1: 0.5 to 3 s T2: 0.5 to 1 s min.

Maximum sensitivity T2

H
L
T2: 5 s min.

Remote Bank Function


The remote bank input signal allows the setting of two kinds of sensitivity adjustment values.

Brown +V

Black; control output


Orange; self-diagnosis
input
Pink

Purple Bank 1: SW = OFF


Bank 2: SW = ON

Blue 0 V

To set two kinds of sensitivity adjustment values, the


purple and blue wires must be connected with each oth-
er and select bank 2 to tune the E3X.

Variable Hysteresis Function (E3X-H11)


Sensing of Plate Level Differences Refer to the following when using the hysteresis adjuster.
(If sensing is impossible with the hysteresis value set to maximum)
Reflection Reflection Reflection
of light of light of light

ON ON
Large hysteresis
differential ON
Small hysteresis differential
OFF OFF OFF

A B A B A B
ON Unstable Unstable OFF ON OFF

Sensing operation is not stable be- Reduce the sensitivity of the E3X with Reduce the hysteresis value with the
cause zone B is within the hystere- the sensitivity adjuster and turn off hysteresis adjuster so that zone A will
sis differential range. zone B. be ON.

3
39
E3X E3X

Set both the sensitivity


1 2
adjuster and hysteresis min max
SENS
Hysteresis
adjuster to maximum. differential
min max adjuster
Sensitivity
adjuster
Decide the position of
the fiber head and that
of the sensing object in
zone A.

(E)

Locate the head in zone


A and turn the sensitivity 1 2
SENS
adjuster counterclock-
wise slowly until the
min max
stable operation indicator
and light reception indi-
cator are OFF (i.e., posi-
tion E as shown in the il-
lustration).

min max
Locate the head
When the NO in zone B and turn the NO
head is located in zone B, hysteresis adjuster counterclockwise slowly
light reception indicator and make sure Set the hysteresis adjust-
that the light reception min max
is lit. er to maximum.
S L indicator S L
is lit.
YES
YES (F)
(G)
S L Locate the head in zone A
and turn the sensitivity ad-
S L 1 2
(H)
juster clockwise until the SENS
stable operation indicator
Set the hysteresis adjust- min max
and light reception indica- min max
er to the point where the tor are OFF (i.e., position
light reception indicator is F as shown in the illustra-
lit (i.e., position E as tion).
shown in the illustration).

(E)
Locate the head in zone (G)
A and turn the sensitivity 1 2
adjuster counterclock- SENS

wise until the light recep-


The light reception indicator min max
NO tion indicator and stable
is lit when the head is located in zone B and
operation indicator are
the light reception indicator is OFF when the
head is located in zone A. OFF (i.e., position O as
S L shown in the illustration).

YES

Sensing is possible.
S L

B A

4
40
E3X E3X

External Diagnostic Input Function


With this function, light projection can be stopped when desired. E3X-Fjj/-VGjj
The operation of the sensor can be checked with this function before No light is emitted from the projection fiber head when self-diagnos-
the E3X is placed into actual operation. tic input is ON.
E3X-Ajj
Light is emitted from the projection fiber head when the self-diag-
nostic input is ON. The sensor, however, will not operate.
NPN Type Brown (+V)
Pink
(external- External-diagnostic input Short
Light projection check (between blue and pink) Open
stops Input)
LED for light projection ON
ON OFF

Indicator ON
Blue (0 V) OFF

Brown (+V)
Pink
(external- By short-circuiting the pink and blue cords, light projection can
check
Light Input) be stopped (with a short-circuit current of 0.2 mA max.).

OFF

Blue (0 V)

PNP Type Brown (+V)

External-diagnostic input Short


ON
Light projection (between brown and pink) Open
stops
Pink LED for light projection ON
(external- OFF
check
Input) Indicator ON
Blue (0 V) OFF

Brown (+V)

OFF By short-circuiting the brown and pink cords, light projection can
Light be stopped (with a short-circuit current of 0.2 mA max.).
Pink
(external-
check
Input)
Blue (0 V)

Special Fiber Units


The following special accessories are available (order separately). Appearance
Contact your OMRON representative for the details.
Fiber Units with Special Length of Stainless L
Steel Tube
Fiber with different lengths of stainless steel tubes are available.
Applicable Models The length can be ordered in increments of 10 mm between
10 mm min. and 120 mm max.
E32-TC200F (tube with 0.9 dia.)
E32-TC200B/DC200F (tube with 1.2 dia.) Tolerance: +1.0 mm if L is 40 mm or less. and +2.0 if L is more
E32-DC200B (tube with 2.5 dia.) than 40 mm. (Note that standard Fiber Units have a 90-mm or
40-mm long stainless steel tube.)

5
41
E3X E3X
Fiber Units with 90° Bend in Stainless Steel Stainless Steel Tube with a 90° Bend at the Base
Tube
Length
Applicable Models
E32-TC200B/TC200F/DC200F ȏ2 R
Appearance

Stainless Steel Tube with a 90° Bend at the Tip

Length

Bending radius ȏ1 (+1)


ȏ1 R
R 5.0 5.0 mm 10.0 mm
R 7.5 7.5 mm 17.5 mm

Bending radius ȏ1 (+1) R 10.0 10.0 mm 20.0 mm

R 5.0 10.0 mm 15.0 mm R 12.5 12.5 mm 22.5 mm

R 7.5 12.5 mm 17.5 mm The length overall is 120 mm max.


Note: If larger ȏ2 is required, use the E39-F11 Sleeve Bender.
R 10.0 15.0 mm 20.0 mm
R 12.5 17.5 mm 22.5 mm
The length overall is 120 mm max.
Note: If larger ȏ1 is required, use the E39-F11 Sleeve Bender.
Sensing Distance for Tubes with 90° Bends
Model Amplifier Bending radius
Standard R5.0 R7.5 R10.0 R12.5
E32-TC200B E3X-Tjj 270 mm 170 mm 220 mm 240 mm 270 mm
E3X-H11 400 mm 260 mm 330 mm 360 mm 400 mm
E3X-Ajj 180 mm 110 mm 140 mm 160 mm 180 mm
E32-TC200F E3X-Tjj 65 mm 30 mm 65 mm 65 mm 65 mm
E3X-H11 100 mm 55 mm 100 mm 100 mm 100 mm
E3X-Ajj 50 mm 30 mm 50 mm 50 mm 50 mm
E32-DC200F E3X-Tjj 20 mm 15 mm 20 mm 20 mm 20 mm
E3X-H11 36 mm 30 mm 36 mm 36 mm 36 mm
E3X-Ajj 18 mm 10 mm 18 mm 18 mm 18 mm

Fiber Unit with Longer Fiber


Applicable Models Appearance
E32-TC200/-DC200
E32-TC200B/-DC200B ȏ
E32-TC200E/-DC200E
E32-TC200F/-DC200F
E32-TC200A The length can be ordered in increments of 1 m between
6 m min. and 20 m max.. (2-m and 5-m fiber length types are
standard for E32-TC200, E32-DC200.)

6
42
E3X E3X
Fiber Length vs. Sensing Distance
Through-beam Fiber Unit Reflective Fiber Unit
(Based on the sensing distance using a fiber length (Based on the sensing distance using a fiber length
of 2 m as 100%) of 2 m as 100%)
Sensing distance (%)

Sensing distance (%)


Fiber length (m) Fiber length (m)

E3X-Ajj, E32-TC200 (Typical) E3X-Ajj, E32-DC200 (Typical)


Sensing distance (mm)

Sensing distance (mm)

Fiber length (m)


Fiber length (m)

43
7
E3X E3X

Dimensions
Fiber Units
Through-beam
(Sold in Pairs)
E32-T11L E32-T12L
Two hexagon clamping nuts (T = 2.4)
M2.6 x Two toothed washers (for M4)
1.4 dia. 0.45 Optical fiber, 2.2 dia.
Sensing head (nickel- 1.4 dia. 2.4 dia. Sensing head (nickel-plated brass) 3 dia. Optical fiber, 2.2 dia.
plated brass) M4x0.7

3 11 3 11
3.2 (14) 2,000
7 (14) 2,000

E32-T21L E32-T22L
Two hexagon clamping nuts
Fiber attachment
Two toothed washers Fiber attachment
Sensing head, 2 dia. (stainless) (E39-F9)
(E39-F9)
Sensing head M3 x 0.5 Heat-shrinkable tubing 25
(nickel-plated brass) 25 0.9 dia. 1.8 dia.
0.9 dia. Optical fiber, 1 dia. 10
Optical fiber, 1 dia. 10

(2)
2.5 (1.7) 1.8 17 12
11 2,000 22 2,000
5.5

E32-TC200 E32-TC200B
E32-TC200B4
Two hexagon clamping nuts
Two hexagon clamping nuts Stainless
1.0 dia. Two toothed washers 1.0 dia. tube Two toothed washers
M2.6 x 0.45 1.2 (SUS304) Sensing head M4 x 0.7 (nickel-plated brass)
Sensing head M4 x 0.7 (nickel-plated brass) dia
max.
Optical fiber, 2.2 dia.
Optical fiber, 2.2 dia. 2.4
2.4 3.2
3.2 3 14 11 2,000
2,000
7 7 90 (40) (see note)

Note: The value in the parentheses is


for the E32-TC200B4.

E32-T22 E32-TC200E Two hexagon clamping nuts


Two toothed washers Fiber attachment
Sensing head M3 x 0.5 (E39-F9)
Heat-shrinkable tubing Fiber attachment (E39-F9) 25
Sensing head 0.5 dia. (nickel-plated brass)
Optical fiber, 25 Optical fiber, 1 dia. 10
0.5 dia. SUS303 1.4 dia. 1 dia. 10

17 12 2.5 1.8
2 dia. 22 2,000 11 2,000
5.5

E32-TC200F
Two hexagon clamping nuts
E32-TC200F4 Two toothed washers
Stainless tube Fiber attachment (E39-F9)
(SUS304) Sensing head M3 x 0.5 25
0.5 dia. (nickel-plated brass)
0.9 dia. min. Optical fiber, 1 dia. 10

Note: The value in the parentheses is


2.5 1.8 for the E32-TC200F4.
90 11 2,000
5.5 (40)
(see note)

E32-TC200A E32-T11
Sensing
head (nickel-
Two hexagon clamping nuts Sixteen, plated brass) Two hexagon clamping nuts
1.0 dia. Two toothed washers 0.265 dia. M4 x 0.7 Two toothed washers
2.6 dia. Sensing head M3 x 0.5 (nickel-plated brass) M2.6 x Protective tube Optical fiber, 2.2 dia.
0.45

1.8 3 dia. Optical fiber, 2.2 dia.


5.5 3.3 15
(1.5) 7 2,000 3.2 2.4
14 (14) 2,000
7

1
44
E3X E3X

E32-T21 Sensing head (nickel-plated brass) M3 x 0.5


Fiber attachment (E39-F9)
Two hexagon clamping nuts
Four, 0.25 dia. 25
Two toothed washers
Protective tube 10
Optical fiber, 1 dia.

2.5 1.8 15
11 2,000
5.5

E32-TC200C
Two hexagon clamping nuts (75)
Sensing head Two toothed washers
1.0 dia. M2.6 x 0.45 M4x0.7 (nickel-
plated brass)
22 dia.

Optical fiber,
7 2.4 2.2 dia.
11 90 400
3 2,000 (when straight)
E32-TC200D
E32-TC200D4 Two hexagon clamping nuts (75)
Stainless Two toothed washers
1.0 dia. tube Sensing head M4 x
(SUS304) 0.7 (nickel-plated
1.2 brass)
dia. 22 dia.
max. Note: The value in the
2.4 Optical fiber, parentheses is for
3.2 2.2 dia. the E32-TC200D4.
7 11 90 400
2,000 (when straight)
90 (40) (see note)

E32-T14L Sensing head, 3 dia. Heat-shrinking


Optical fiber,
(stainless) tubing
2.2 dia.
45°

2.8
1.5
3dia 1 1.5
30 12
35 2,000

Sensing surface

E32-T24
Sensing head 1 dia. Fiber attachment (E39-F9)
SUS304 25
Protective tube
2 dia. 1.4 dia. Optical fiber, 1 dia. 10
45%

1
0.5 1.5
15 15 12
35 2,000

E32-T14 E32-T17L
Heat resistive ABS Sensing head
Lens unit (PMMA) 8.2 (ABS) M14 x 1 Two hexagon clamping nuts
4.4 dia. 10-mm dia.
lens (PMMA) Optical fiber, 2.2 dia.
7

R3.5 Optical axis Optical fiber, 2.2 dia.


Two, 3.2 dia.

7 8
10.5
19 5
10+0.2 23
2.5 9.2 42
16 11.2 2,000 10,000

E32-T12F
4-mm
dia. lens
Sensing head, 5 dia. Fluoride resin 4 dia. Optical fiber, 2.2 dia.

20
2,000 100

2
45
E3X E3X

E32-M21
Two hexagon clamping nuts
Sensing head Two toothed washers Note: One set of silicone tubes is black while the other
M3 x 0.35
Silicone tube Plastic fibers, four, 1 dia.
set is gray for easy identification when they are
(SUS303)
connected to the light source and receiver.

Sleeve

13
28

1.8
11 2,000
23

E32-T51
Two hexagon clamping nuts Note: Resistant temperature is 150°C.
1.5 dia. Two toothed washers Resistant temperature is 130°C
Sensing head M4 x 0.7 (nickel-plated brass) when used continuously.

2.85 dia.
7 2.4 Optical fiber, 2.2 dia.
1 15
17 2,000

E32-T61
Two hexagon clamping nuts
Two toothed washers SUS flexible tube Hexagon clamping screw
1.0 dia. M2.6 x 0.45 2.8 dia. 4 dia. 5 dia. Sleeve
Sensing head M4 x 0.7
(SUS303)

4 dia. (See note)


7 3 2.4 13
5
20 10 2,000 28
A B

Note: Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C.
The operating temperature of section B must also be within the withstand temperature
range of the Amplifier.

46
3
E3X E3X

Reflective
E32-D11L Two hexagon clamping nuts
Two toothed washers
Two, 1.4 dia. Sensing head (nickel-plated brass) M6 x 0.75
4 dia.
Two optical fiber, 2.2 dia.

5.2 3 2.4
20 2,000
10

E32-D12
2,000 (standard length)
3 dia. 15 135

Two, 1 dia.
Sensing head (stainless)
Heat-shrinkable tubing Optical fibers, two, 2.2 dia.

E32-D21L Two hexagon clamping nuts Two fiber attachments (E39-F9)


Two toothed washers 25
Two, 0.9 dia. Sensing head M4 x 0.7 (nickel-plated brass) 10
Optical fiber, two, 1 dia.

3.2 3 2.4
7 15 2,000

Two fiber attachments (E39-F9)


E32-D22L 25
10
Two, 0.9 dia. 2.7 dia. Sensing head 3 dia. Optical fiber, two, 1 dia.
(nickel-plated brass)

3
15 2,000

E32-DC200 Two hexagon clamping nuts

Two, 1.0 dia. Two toothed washers


4 dia. Sensing head M6 x 0.75 (ADC)

Optical fiber, 2.2 dia.


3
2.4
4.8
17 2,000
10
E32-DC200B
E32-DC200B4 Stainless Two hexagon clamping nuts
Two, 1.0 dia. tube Two toothed washers
(SUS304) Sensing head M6 x 0.75 (fine screw)
2.5 dia.
max.
Note: The value in the
parentheses is for
2.4 Optical fiber, 2.2 dia. the E32-DC200B4.
5.2 17 2,000
10 90 (40)
(see note)
E32-DC200E Two fiber attachments (E39-F9)
Two hexagon clamping nuts 25
Two toothed washers 10
Two, 0.5 dia. Sensing head M3 x 0.5 (SUS304)
Optical fiber, two, 1 dia.

2.5 1.8
11 2,000
5.5

4
47
E3X E3X

E32-DC200F Two hexagon clamping nuts


Fiber attachment (E39-F9)
E32-DC200F4 Two toothed washers
25
Stainless tube Sensing head M3 x 0.5
Two, 0.5 dia. (SUS304) 10
(SUS304)
1.2 dia. min. Optical fiber, two, 1 dia.

2.5 1.8
90 11 2,000
5.5 (40)
(see note)
Note: The value in the parentheses is for the E32-TC200F4.

E32-D11 Sensing head


(SUS303) Two hexagon clamping nuts
Sixteen,
0.265 dia. M6 X 0.75 Two toothed washers (10 teeth)
Protective tube Optical fiber, two, 2.2 dia.

2.4
5.2 15
17 2,000
10

E32-D21 Fiber attachment (E39-F9)


Sensing head (nickel-plated brass)
M3 x 0.5 Two hexagon clamping nuts 25
Two toothed washers 10
Four, 0.25 dia. Protective tube Optical fiber, two, 1 dia.

2.5 1.8 15
11 2,000
5.5

E32-DC200C Two hexagon clamping nuts


Two toothed washers (150)
Two, 1.0 dia. Sensing head M6
x 0.75 (nickel-
plated brass)
22 dia.

Optical fiber,
2.4 2.2 x 2 dia.
5.2
10 17 90 400
2,000 (when straight)

E32-DC200D
E32-DC200D4 Two hexagon clamping nuts
Note: The value in the
(150) parentheses is for
Stainless Two toothed washers
Two, 1.0 dia. tube Sensing head M6 the E32-DC200D4.
2.5 dia. (SUS304) x 0.75 (SUS304)
max.
22 dia.

Optical fiber,
2.4 two, 2.2 dia.
5.2
90 17 90 400
10 2,000 (when straight)
(40) (see note)

Sleeve
E32-DC9G 4
Stainless tube
E32-DC9G4 1.2 dia. max.
8 15

Do not bent the stainless


tube in this range.
10 7.5 6
90 17 13
(40)
(see note) Note: The value in the parentheses is for the E32-TC200F4.
E32-D33 Fiber attachment (E39-F9)
25
Sensing head
(SUS303) Optical fiber, two, 1 dia. 10
Two, 0.25 dia. 0.8 dia. 3 dia. Heat-shrinkable tubing

15 15 12
35 2,000

5
48
E3X E3X

E32-CC200
Sixteen, 0.25 dia. Two hexagon clamping nuts
for light reception 1.0 dia. for light
emission Two toothed washers
2.5 dia. Sensing head M6 x 0.75 Optical fiber, two, 2.2 dia.
(nickel-plated brass)

2.4
5.2 3 2,000
23
10

Note: The fiber for the light source is identified by a white line.

E32-D32 Two fiber attachments (E39-F9)


25
Light source fiber Sensing head SUS303 Optical fibers, two, 1 dia. 10
(0.5 dia.) 2 dia. 3 dia. Heat-shrinkable tubing

15 2 12
Receive fiber
(0.25 dia.) x 4 22 2,000

Note: The fiber for the light source is identified by a white line.

E32-D32L
2,000 (standard length)
15 400 15 1,570
Light source (1 dia.)

Receive (0.265 dia.) x 16


Sensing head, 3 dia. (stainless) Optical fibers, two, 2.2 dia.
Branching box, 6 dia.
(heat-resistive ABS
black resin)

Note: The fiber for the light source is identified by a yellow dotted line.

E32-D14L Sensing head Optical fiber, two, 2.2 dia.


(stainless)
Heat-shrinkable tubing
45°
5.7

1.5
6 dia. 2
1
30 12
35 2,000
Light baffle

Sensing surface
Two fiber attachments (E39-F9)
E32-D24 25
Sensing head (SUS304) 10
Heat-shrinkable tubing Optical fibers, two, 1 dia.
2 dia. 3 dia.
45%

1
0.5 1.5
15 15 12
35 2,000

Light baffle Sensing surface

E32-D12F
Sensing head, 6 dia. Optical fiber, two, 2.2 dia.
Fluoride resin 5 dia.

16
2,000 100

6
49
E3X E3X

Two hexagon clamping nuts


E32-D51 Two toothed washers Optical fiber, 2.2 dia.
Two, 1.5 dia.
Sensing head,M6 x 0.75*
*nickel-plated brass

4.9
Note: Resistant temperature is 150°C.
Resistant temperature is 130°C
2.4 when used continuously.
3.1 13
10 3
17 2,000

E32-D61
Two hexagon clamping nuts
Two toothed washers SUS304
Sensing head (SUS303) SUS flexible tube Sleeve
1.4 dia. M4 x 0.7 Hexagon clamping screw
M3 x 0.75
5 dia. 3.5 dia.

8 15

10 5 6.5 (See note) 6.4


3 2 2.4 3 16.5 13
20 2,000
5
A B

Note: Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C. The operat-
ing temperature of section B must also be within the withstand temperature range of the Amplifier.
E32-D73
Two hexagon clamping nuts
SUS303
Two toothed washers Sleeve
Sensing head Hexagon clamping screw
M4 x 0.7 (SUS303) SUS flexible tube
1.0 dia. 1.25 dia. 2.5 dia. 5 dia.
4 dia. 2.8 dia.
1.65 dia.
8 15

7
2.4 (See note)
5 5 5 6.5 6.4
60 20 10 2,000 16.5 13
A B C

Note: Section A resists 400°C, section B resists 300°C, and section C (which is inserted to the Amplifier)
resists 110°C. The operating temperature of section C must also be within the withstand temperature
range of the Amplifier.

E32-R21
Two fiber attachments (E39-F9)
Two hexagon clamping nuts
25
Lens Two washers
Sensing head Silicone tube 10
(PMMA) M6 x 0.75
Optical fibers, two, 1 dia.

5 dia.

2.2
10 3
2.8 11 14
17.8 2,000
27.8

Nameplate
E32-R16 27 15

13

1.5
10 3.2 1.5 3.2
7.2 16
(6) 4

15.2 8
21.5

Optical fiber, two, 2.2 dia.


Standard length: 2 m
Lens (PMMA) 21 22.5 16+0.2
17
Two, M3 screws (attachment)
1

Mounting bracket (attachment)

7
50
E3X E3X

20
E32-L25 E32-L25A 5 10
4
4.8 6.5
20
5 20 6.5
10
4
4.8
6.5
White line Optical fiber, two, 2.2 dia.
20 6.5
Two, 3.2 dia.,
6 dia. spot facing

Two, 3.2 dia., 2,000 White line


2,000
6 dia. spot facing

Sensing head (ABS) Optical fiber,


Note: The fiber for the light source is two, 2.2 dia.
identified by a white line.

E32-L25L
18 Two fiber attachment
4 (E39-F9)

6 25

16 Two, 1 dia. optical fibers 10


6.5

Sensing head
(PC) Two, 3.2 dia, 6 dia. 2,000
counter sinking

E32-L24L
4
3.6
18 Side view prism (PC)
3.3
1.5 Two fiber attachment
3.3 4 (E39-F9)

Optical 6 25
20 axis Two, 1 dia. optical fibers
6.5 10

Sensing head
(PC) Two, 3.2 dia, 6 dia.
2,000
counter sinking

8
51
E3X E3X

Fine Through-beam 0.4 1.8


E32-T22S Sensing head
E32-T24S (nickel-plate brass)
Optical fiber 2.2 dia.

3.5 dia. 11 3.2


17.6

Mounting bracket (attachment)


3 3.2
10
20.5 2,000

2 dia.

2 Sensing surface

E32-T84S
2,000 (standard length)
(see note)

4 dia. 2.9 dia. flexible 4 dia. 5 dia. Sleeve


tube (stainless)

3.5 dia.

Sensing head (stainless)

3 dia.

Lens (2 dia.)

Note: Section A resists 200°C and section B (which is inserted to the Amplifier) resists 110°C. The operating
temperature of section B must also be within the withstand temperature range of the Amplifier.

Slot Fiber Units


E32-G14
Sensing head (ABS)
36.3 2,000
25.2
20
9.2
Mounting Holes
R1.6 R1.6
Two, M3

R3.5
24 10 Optical axis 3.2 9.0 9.4
Lens
(PMMA)

4 1.6 1.6 Optical fiber, 2.2 dia.


23.5 9.4

7.4 7.0

9
52
E3X E3X

Liquid Level Fiber Units


E32-D82F1/E32-D82F2
(Liquid Contact Model)
9 dia. fiber connector
6 dia. sensing head (Teflon) (nickel-plate brass) Two, 2.2 dia. optical fiber
(see note 2)

To Amplifier
Bending-prohibited length:
150 (350) (see note 1)

Note: 1. The value in the parentheses is for the E32-D82F2.


2. Since the 2-m optical fiber on the Amplifier side is made of
plastic, the fiber is trimmable.

E32-L25T (Pipe
Mounting Model)
Optical axis

Two, 3.2 dia.


lens (PC)
Two, fiber attachment

Two, 1 dia. optical fiber

Mounting hole

Sensing head 2,000 (standard length)


(PC)

53
10
E3X E3X

E32-T16 20
2 (R)
10.2 4 3.2

Mounting Holes 0.5-mm Wide Silt Seal


20 (Sold in Pairs)
4
6
20 0.5

Sensing 2 (R) 4
1.2 2 (R)
head
(ABS) 4.5
15.5 11
8.4 Two, M3 2.3
8.85 3 15 23
5.5
3.2
Black

27 25 20
1-mm Wide Silt Seal
(Sold in Pairs)
Lens 6
(2 x 10) 58
6 dia. 1
(PMMA)
43.2
Two, 3.2 dia. 4

2,000
Mounting bracket
E39-L4 15 23

Black

Fiber 2.2 dia. 33

E32-T16P

Two, 3.2 dia., 6 dia counter sinking


14.5 4
10.7 0.5-mm-wide Slit Seal E32-T16P with E39-L94
(Sold in Pairs) Mounting

3.4 35
20
0.5 2
4 4.8
19 27
20
Sensing head 13.4
(2 x 11) Two, M3
(PMMA) 20
4 4
26.4

Sensing head Black


(heat-resistive ABS) 12.2
3.2

1-mm-wide Slit Seal


(Sold in Pairs)
2,000
3.4 Sensing
head 19
1
2.2-dia. optical fiber

13.4 52
4
43.2
26.4

23.2
Black E39-L94 Mounting Bracket
2.2-dia.
fiber

54
11
E3X E3X

Amplifier
E3X-T11 Light reception indicator
17.8
E3X-T21
9

Stable operation Tuning indicator


indicator
12 4
6.5 1.2 59

4.2 11
Two, 2.4

32
8 25

0.4 12.5
8.4
Cord: 2-m polyvinyl chloride-covered cord 3.9
(4-mm dia., 3 cores*) 22.5 16
Weight: Approx. 100 g 6 13 35.5 6
*The cords for the E3X-T21 model has 6 cores. 3.2 dia.
Mounting bracket (removable)

3.4 2
22.5 16

E3X-H11 Light reception indicator


15.8
E3X-Ajj
E3X-Fjj
E3X-VGjj 9

Stable operation indicator

59 4

Two, 2.4 dia.

30
8 25

12.5
8.4

3.9
6 22.5 16 6
13 35.5 Mounting bracket (removable)
Cord: 2-m polyvinyl chloride-covered cord 3.2 dia.
(4-mm dia., 5 cores*)
Weight: Approx. 100 g
*The cords for the E3X-A11, E3X-A41, and
E3X-VG11 models have 3 cores.

3.4 2
22.5 16

55
12
E3X E3X

Reflector
Reflector (Small) Reflector
E39-R3 E39-R1
11 Adhesive tape 40.3
Two, 3.5 dia. 34
7.5
7

20

Note: Mounting bracket is


attached.
0.2

59.9 52

34.8 25.4 34 38

1.6 2.7
19.3 1.2
Two, M3 2.6

Attachments
E39-F1 E39-F2 E39-F3
Lens Kit Side-view Attachment Convergent Beam Conversion Kit
M3 toothed
M2.6 x 0.45 M2.6 Two, 4 dia. washers Two, M3 x 3 Slotted
Effective depth: 3.8 Effective depth: 3.2 Two, 3.2 +0.2
0 dia. head machine screw
Spot facing depth: 0.9 2.8 dia. Spot facing depth: 0.9

4 dia. 4 dia.
5.7 18 6.4 12
8.9 9.2

6.4
3 8+0.2 6.5 M3 x 6 Angle
Note: One set includes two units. fixing screw
3.6
20.7
8.5

E39-F5 E39-F3A
Side-view Diffuse Reflective Conversion Kit Reflective Lens Unit (for the E32-D32)
(for the E32-TC200A)
Two, M3
Sensing hole Fiber unit mounting M2 x 2
Two, 3.2 dia. Two, 3.2 dia. 4 dia.
holes (E32-TC200A)
12.2 Mounting hole
6 dia.
2.1
4 Lens (3.7 dia.) 3
13 13 2.1 dia.
23
2.6
4
10.5+0.1 5
18

56
13
E3X E3X

Protective Spiral Tubes


E39-F32A, E39-F32A5
E39-F32B, E39-F32B5
M3 x 0.5 depth: 4 Head connector End cap 3 dia.
4.6 dia.

6 dia.

12 12
L

Note: 1. L is as follows:
E39-F32A and E39-F32B: 1,000
E39-F32A5, E39-F32B5: 500
2. A pair of E39-F32A(5)’s is sold as E39-F32B(5).
E39-F32C, E39-F32C5
M4 x 0.7 depth: 4 Head connector 5.6 dia. End cap 4 dia.

7 dia.

12 12
L

Note: L is as follows:
E39-F32C: 1,000
E39-F32C5: 500
E39-F32D, E39-F32D5
M6 x 0.75 depth: 4 Head connector 7 dia. End cap 5 dia.

8.5 dia.

12 12
L

Note: L is as follows:
E39-F32D: 1,000
E39-F32D5: 500

Accessories
E39-F4 Fiber Cutter

Holes for standard fiber Holes for thin fiber

E39-F9 Attachment for Thin Fiber E39-F10 Fiber Connector

Insertion mark Retention clip Splice Retention clip Fiber


1.1 dia.

(2.4 dia.)
10 11.7 26 3 dia. 12.8 2.2 dia.
3.6 dia. 3.8 dia.
25

Note: One set includes two Units.

14
57
E3X E3X

E39-G3 Manual Sensitivity Adjustment Knob


Note: Cannot be used with the E3X-Tjj.

10 dia.

E39-G4 Protective Cover


Note: Cannot be used with the E3X-Tjj.

15
58
E3X E3X

Installation
Connections
Connection with S3D2 Sensor Controller Connection with S3D8 Sensor Controller

Blue Black

Black Blue 0 V

Brown Brown

+12 V 0V +12 V IN1


7 8 9
10 11 12

IN1 IN2

NORM INV
4 5 6
1 2 3

Note: A maximum of two E3X Optical Fiber Photoelectric Note: A maximum of eight E3X Optical Fiber Photoelectric Sen-
Sensors can be connected. sors can be connected.

Power supply voltage Output Functions NPN input PNP input


100 to 240 VAC Relay AND, OR S3D2-AK-US S3D2-AKB-US
AND, OR, and timer S3D2-CK-US S3D2-CKB-US
Flip-flop S3D2-BK-US ---
Transistor AND, OR, and timer S3D2-CC-US S3D2-CCB-US

16
59
E3X E3X

Precautions
Fiber Units
Tightening Force Fiber Connection and Disconnection
The tightening force applied to the Fiber Unit should be as follows: The E3X Amplifier has a push lock. Connect or disconnect the fibers
to or from the E3X Amplifier using the following procedures:
Screw-mounting Model 1. Connection
Spring mounting clip
Toothed washers

Nuts
(attachment)
Insert the fibers into the E3X Amplifier and press the push lock until
Column Model the Amplifier clicks to lock the fibers. The fibers will have insertion
Retaining screw Clamping torque marks when they are cut with the E39-F4 (Fiber Cutter). The portion
(M 3 max.) 3 kgf S cm max. from the tips to the insertion mark should be inserted to the E3X.
2. Disconnection
Be sure to press the push lock again to unlock before pulling out the
fiber, otherwise the fiber may be deteriorated.
Fiber Insertion
If the portion from the tip to the insertion mark of the fibers are not
inserted into the Amplifier Unit, the sensing distance will be re-
duced.
Fiber units Clamping torque
M3/M4 screw 8 kgf S cm max. (0.78 N S m) 2.2-mm dia. Fiber
Amplifier
M6 screw 10 kgf S cm max. (0.98 N S m) Insertion mark

2-mm dia. column 3 kgf S cm max. (0.29 N S m)


3-mm dia. column 3 kgf S cm max. (0.29 N S m)
E32-D14L 10 kgf S cm max. (0.98 N S m) Fiber unit
E32-T12F 8 kgf S cm max. (0.78 N S m) 12.6 mm

E32-D12F 8 kgf S cm max. (0.78 N S m)


Thin Fiber with the E39-F4 Attachment
E32-T16 5 kgf S cm max. (0.49 N S m)
The portion from the Amplifier
E32-R21 6 kgf S cm max. (0.59 N S m) tips to the insertion
mark should be in-
E32-M21 Up to 5 mm to the tip: 5 kgf S cm max. serted into the E3X.
(0.49 N S m)
Up to 5 mm from the tip: 8 kgf S cm max.
(0.78 N S m)
Fiber unit
E32-L25A 8 kgf S cm max. (0.78 N S m) 12.6 mm

Use a proper-sized wrench. Fiber with Fixed Length


The portion from the
tips to the insertion Amplifier
mark should be in-
serted into the E3X.

12.6 mm

60
17
E3X E3X

Cutting Fiber Connection


Insert a fiber into the Fiber Cutter and determine the length of the Do not pull or press the Fiber Units. The Fiber Units have a with-
fiber to be cut. stand force of 1 kg or 3 kg (pay utmost attention because the fibers
Press down the Fiber Cutter in a single stroke to cut the fiber. are thin).
When the fiber is cut, an insertion mark is inscribed on the fiber. Do not bend the Fiber Units beyond the permissible bending radius.
Do not bend the edge of the Fiber Units.
For a 2.2-mm dia. standard fiber only.
40 mm max.
12.6 Insertion mark

Correct
Amplifier
Fiber unit
2.2-dia.

Insert a fiber into the Fiber Cutter in the direction indicated by the 20 mm max.
arrow (refer to the following figure).
2 Incorrect

Do not apply excess force on the Fiber Units.


1
Fiber
Fiber unit
unit
The cutting holes cannot be used twice. If the same hole is used Nylon wireholder
twice, the cutting face of the fiber will be rough and the sensing dis- Correct
tance will be reduced. Always use an unused hole.
Metal holder
Use either one of the two holes on the right (refer to the following
figure) to cut a thin fiber as follows:
Incorrect
1. An attachment is temporarily fitted to a thin fiber before
shipment.
The Fiber Head could be broken by excessive vibration. To prevent
this, the following is effective:
Temporarily fitted

2. Secure the attachment after adjusting the position of it A Aone-turn


one-turn loop
loop cancan
absorbvibrations
absorb vibrations.
in the direction indicated by the arrow.
3. Insert the fiber into the E39-F4 to cut.

Tape
Cutter E39-F4
Two holes for
thin fiber

Three holes for


standard fiber
(2.2 mm dia.)

Note: Insert the fiber in the direction indicated by the arrow.

18
61
E3X E3X

Bending Radius Handling


E39-F11 Sleeve Bender E32-D51/-T51 Heat-resisting Fiber
The bending radius of the stainless tube should be as large as pos- The bending radius of the fibers should be 35 mm min.
sible. The smaller the bending radius becomes, the shorter the Connecting fibers via the E39-F10 Fiber Connector is not possible.
sensing distance will be.
The withstand temperature of the Heat-Resisting Fibers is 150°C
Insert the tip of the stainless sleeve to the Sleeve Bender and bend max. In continuous operation, the ambient temperature should be
the stainless sleeve slowly along the curve of the Sleeve Bender (re- 130°C max.
fer to the figure).
E32-T14/-T51
1.2 dia. 1.2 dia.
max. 1.3 dia. max.
If the sensor is ON because some object in front of the lenses re-
min. flects light, attach the black seals (sold together) to the lenses.
R 10
R 12.5 R5
E32-T14/-G14
R 7.5

Fiber tip position mark Seal

E32-L25 (A) Wafer Sensor


Stainless tube
Insert the fiber with a white line into the light projection side of the
Amplifier.
The tightening force of the sensor head is 8 kgf S cm (0.75 N S m).
Avoid places where water could be sprayed onto the E32-L25(A).
E32-T16 Slit Seal (Attachment)
Peel the E32-T16 Slit Seal off the ground paper and affix the Slit
Seal to the sensing face of the sensor so that the corners of the Slit
90o max. 10 Seal fit in with the corners of the sensing face. To sense an object at
a distance of 30 cm max., a 0.5-mm wide Slit Seal must be used.

10

Do not bend here.


E32-T16 Sensing Head
Attachment slit

Amplifier Units Others


When power is off:
Mounting The moment power is turned off, the E3X could output a pulse signal
Mounting which could affect the operation of the devices connected to it. This
1. Mount the front part on the mounting bracket (sold together) will happen more often if power is supplied to the E3X from an exter-
or a DIN rail. nal power supply, thus affecting the connected timer and counter.
Use a built-in power supply as much as possible to avoid this.
2. Press the back part onto the mounting bracket or the DIN rail.
If power is supplied to a photoelectric sensor through a cord that is
wired together with other power lines in the same duct, the cord will
be influenced by the power lines and malfunctioning of the photo-
electric sensor or damage could result. Wire the cord separately or
3 use a sealed cord to supply power to the photoelectric sensor.
In the case of the cord is extended, use a wire with 0.3 mm2 max..
The total length of the cord should be 100 m max.
2
1 DIN rail

Power lineline
Power
Dismounting
By pulling back the lock (yellow) on the bottom with a flat blade
screwdriver, the Amplifier can be dismounted with ease.
In the case of side mounting, attach the mounting bracket on the
Amplifier first, and secure the Amplifier with M3 screws and wash- Power supply:
ers. The diameter of the washers should be 6 mm max. If a standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, or otherwise the E3X can malfunction, influenced by the
switching noise of the power supply.
The supplied voltage must be within the rated voltage range. Unreg-
ulated full- or half-wave rectifiers must not be used as power sup-
plies.
Washers (6 dia. max.) Do not use a hammer to hit the Amplifier when mounting or the Am-
plifier will loose watertightness.

19
62
E3X E3X

Attachment Units
Applications E39-F3A Reflective Unit Lens
E39-F10 Fiber Connector When the E39-F3A is attached to the fiber, the E3X can sense the
light reflected from the interior of the E39-F3A. If this happens, ad-
Use the following procedure (refer to the figure) to connect fibers via just the sensitivity of the E3X Amplifier with Sensitivity Adjustor.
the Fiber Connector.
Place a sensing object or white paper at the sensing distance set
Splice and adjust the insertion length of the Fiber Unit to the E39-F3A so
that the light spot is as small as possible. Then fix the position of the
Retention Unit Fiber Unit with the hexagonal wrench (attachment)
Retention Unit

Tighten

Loosen A
Lens
Each fiber should be as close as possible before they are con- B
nected. Insertion
Sensing distance will be reduced by approximately 25% when fibers Fiber Unit (E32-D32)
are connected.
Only fibers with 2.2 mm dia. can be connected. A: The focus is farther than the E39-F3A.
Protective Spiral Tube B: The focus is closer than the E39-F3A
Insert a fiber to the Protective Spiral Tube from the head connector
side (screwed) of the tube. E39-G3 Sensitivity Adjustor
1. Remove the cover of the E3X.
2. Attach the E39-G3 (refer to the figure).
Protective spiral Fiber Unit Cover
tube
Knob

Push the fiber into the Protective Spiral Tube. The tube should be
straight so that the fiber is not twisted when inserted. Then turn the
end cap of the spiral tube.

Protective spiral Fiber Unit


tube
3. After the cover is attached to the case, turn the knob of the
E39-F3A clockwise or counterclockwise once. To confirm
that the knob has been set properly, turn the knob clockwise
Secure the Protective Spiral Tube on a suitable place with the at- or counterclockwise until you hear a click (8 turns max. are
tached nut. necessary).
Note: E3X looses watertightness if E39-G3 is attached (the en-
Mounting panel closure rating will be IP50).
Hexagon clamping nut

Fiber Unit
Protective spiral Toothed washer
tube

Use the attached saddle to secure the end cap of the Protective Spi-
ral Tube. To secure the Protective Spiral Tube at a position other
than the end cap, apply tape to the tube so that the portion becomes
thicker in diameter.

Saddle

Tube

End cap

20
63
E3X E3X

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. E215-E1-3 In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Systems Components Division H.Q.
28F Crystal Tower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan Printed in Japan