Service Manual Supplement
First Edition
                            Second Printing
                            Part No. 82682
Platform Overload
Maintenance
Maintenance Procedures                                                                   August 2003
Information
This Service Manual Supplement provides
maintenance procedures for the Platform
Overload System which are not included in your
Service Manual. Please add these maintenance
procedures to your Service Manual and to the
Maintenance Inspection Report for your machine.
                                                  This symbol in the text means the result applies to
                                                  the following machines:
                                                  Z-30/20N                       Z-45/25 Bi-energy
                                                  Z-34/22 IC                     Z-45/25J Bi-energy
                                                  Z-34/22 DC                     S-40
                                                  Z-34/22 Bi-energy              S-45
                                                  Z-45/25 IC                     S-60
                                                  Z-45/25J IC                    S-65
                                                  Z-45/25 DC                     S-80
                                                  Z-45/25J DC                    S-85
                                                  Z-60/34
                                                  This symbol in the text means the result applies to
                                                  the following machines:
                                                  Z-80/60                        S-100
                                                  S-105                          S-120
                                                  S-125
2                               Service Manual Supplement                             Part No. 82682
August 2003                                                                       Maintenance Procedures
                                           Maintenance Procedures
Grease the Platform Overload                           Test the Platform Overload
Mechanism                                              System
                 Genie specifications require                            Genie specifications require that
                 that this procedure be performed                        this procedure be performed every
                 every 500 hours or 6 months,                            500 hours or six months.
                 whichever comes first. Perform
                                                       Testing the platform overload system regularly is
                 this procedure more often if dusty
                                                       essential to safe machine operation. Continued
                 conditions exist.
                                                       use of an improperly operating platform overload
Application of lubrication to the platform overload    system could result in the system not sensing an
mechanism is essential to safe machine operation.      overloaded platform condition. Machine stablity
Continued use of an improperly greased platform        could be compromised resulting in the machine
overload mechanism could result in the system not      tipping over.
sensing an overloaded platform condition and will
result in component damage.                                              Perform this procedure with the
                                                                         machine on a firm, level surface.
1 Locate the grease fittings on each pivot pin of
                                                       1 Turn the key switch to platform control. Start the
  the platform overload assembly.
                                                         engine from the platform controls.
2 Thoroughly pump grease into each grease
                                                       2 Level the platform.
  fitting using a mulit-purpose grease.
                                                       3 Determine the maximum platform capacity.
                 If your machine is not equipped
                                                         Refer to the machine serial plate.
                 with grease fittings on the pivot
                 pins, remove the pivot pins and
                 grease them.
Part No. 82682                               Service Manual Supplement                                       3
Maintenance Procedures                                                                       August 2003
MAINTENANCE PROCEDURES
4 Using a suitable lifting device, place an         6 Add an additional test weight to the original test
  appropriate test weight equal to that of the        weight to overload the platform based on your
  maximum platform capacity in one of the             maximum platform capacity:
  locations shown.
                                                    Maximum capacity                Add additional weight
                                                    500 lbs / 227 kg                        +75 lbs / 34 kg
                                                    600 lbs / 272 kg                        +90 lbs / 41 kg
                                                    750 lbs / 340 kg                       +113 lbs / 51 kg
                                                       Result:
                                                           The alarm should be sounding.
                                                           The platform overload indicator light should
                                                           be flashing at both the ground and platform
                                                           controls.
    Result: The platform overload indicator light
    should be off at both the ground and platform
    controls.                                              The alarm should be sounding.
                                                           The platform overload indicator light should
5 Carefully move the test weight to each                   be flashing at the platform controls and
  remaining location.                                      “PLATFORM OVERLOAD” should be
    Result: The platform overload indicator light          displayed on the LCD screen at the ground
    should be off at both the ground and platform          controls.
    controls.                                                          If the alarm does not sound and
                                                                       the platform overload indicator
                                                                       light does not come on with the
                                                                       test weights in any of the platform
                                                                       locations, the platform overload
                                                                       system needs to be calibrated.
                                                                       See, How to Calibrate the Platform
                                                                       Overload System.
                                                                       There may be an approximate 2
                                                                       second delay before the overload
                                                                       indicator light turns on and the
                                                                       alarm sounds.
4                                  Service Manual Supplement                              Part No. 82682
August 2003                                                                        Maintenance Procedures
                                                                          MAINTENANCE PROCEDURES
7 Carefully move the test weights to each              10 Test all machine functions from the ground
  remaining location in the platform.                     controls.
   Result:                                                Result: All ground control functions should not
                                                          operate.
       The alarm should be sounding.
       The platform overload indicator light should                     Machine functions should still
       be flashing at both the ground and platform                      operate with auxiliary power at the
       controls.                                                        ground controls.
                                                       11 Lift the test weights off the platform floor using a
       The alarm should be sounding.                      suitable lifting device.
       The platform overload indicator light should
                                                          Result: The platform overload indicator light and
       be flashing at the platform controls and
                                                          alarm should turn off at both the ground and
       “PLATFORM OVERLOAD” should be
                                                          platform controls.
       displayed on the LCD screen at the ground
       controls.                                                        There may be an approximate 2
                                                                        second delay before the overload
                 If the alarm does not sound and
                                                                        indicator light and alarm turn off.
                 the platform overload indicator
                 light does not come on with the       12 Test all machine functions from the ground
                 test weights in any of the platform      controls.
                 locations, the platform overload
                 system needs to be calibrated.           Result: All ground control functions should
                 See, How to Calibrate the Platform       operate normally.
                 Overload System.                      13 Turn the key switch to platform control.
                 There may be an approximate 2         14 Test all machine functions from the platform
                 second delay before the overload         controls.
                 indicator light turns on and the
                 alarm sounds.                            Result: All platform control functions should
                                                          operate.
8 Test all machine functions from the platform
  controls.                                                             If the platform overload system is
                                                                        not operating properly, see How to
   Result: All platform control functions should not                    Calibrate the Platform Overload
   operate.                                                             System.
9 Turn the key switch to ground control.
Part No. 82682                              Service Manual Supplement                                         5
Maintenance Procedures                                                                      August 2003
MAINTENANCE PROCEDURES
How to Calibrate the Platform                        Determine the limit switch trigger point:
Overload System                                      4 Gently move the platform up and down by hand,
                                                       so it bounces approximately 2.5 to 5 cm. Allow
                                                       the platform to settle.
                                                       Result: The overload indicator light and the
                Genie specifications require that      alarm is on. Slowly tighten the load spring
                this procedure be performed every      adjustment nut by turning it clockwise just until
                1000 hours of operation or yearly.     the overload indicator light and alarm turns off.
Yearly calibration of the platform overload system                   The platform will need to be
is essential to safe machine operation. Continued                    moved up and down and allowed
use of an improperly calibrated platform overload                    to settle in between adjustments.
system could result in the system failing to sense
                                                                     There may be an approximate 2
an overloaded platform. The stability of the
                                                                     second delay before the overload
machine is compromised and it could tip over.
                                                                     indicator light turns on and the
                Perform this procedure with the                      alarm sounds.
                machine on a firm, level surface.      Result: The overload indicator light and
1 Level the platform.                                  alarm is off. Slowly loosen the load spring
                                                       adjustment nut by turning it counterclockwise
2 Determine the maximum platform capacity.             just until the overload indicator light and alarm
  Refer to the machine serial plate.                   turn on.
3 Using a suitable lifting device, place an                          There may be an approximate 2
  appropriate test weight equal to that of the                       second delay before the overload
  maximum platform capacity at the center of the                     indicator light turns on and the
  platform floor.                                                    alarm sounds.
                                                                     The platform will need to be
                                                                     moved up and down and allowed
                                                                     to settle in between adjustments.
6                                  Service Manual Supplement                             Part No. 82682
August 2003                                                                         Maintenance Procedures
                                                                            MAINTENANCE PROCEDURES
Confirm the setting:                                    8 Add an additional test weight to the original test
                                                          weight to overload the platform based on your
5 Turn the key switch to platform control. Start the      maximum platform capacity:
  engine from the platform controls.
6 Lift the test weight off the platform floor using a   Maximum capacity                Add additional weight
  suitable lifting device.                              500 lbs / 227 kg                        +10 lbs / 4.5 kg
7 Place the test weight back onto the center of         600 lbs / 272 kg                        +12 lbs / 5.4 kg
                                                        750 lbs / 340 kg                        +15 lbs / 6.8 kg
  the platform floor using a suitable lifting device.
   Result:
                                                           Result:
       The alarm should be off. The platform
       overload indicator light should be off at both          The alarm should be sounding.
       the ground and platform controls.                       The platform overload indicator light should
                                                               be flashing at both the ground and platform
                                                               controls.
       The alarm should be off. The platform
       overload indicator light should be off at the
       platform controls and there should be no                The alarm should be sounding.
       error message on the LCD display at the                 The platform overload indicator light should
       ground controls.                                        be flashing at the platform controls and
                                                               “PLATFORM OVERLOAD” should be
                 There may be an approximate 2                 displayed on the LCD screen at the ground
                 second delay before the overload              controls.
                 indicator light and alarm turn off.
                                                                           There may be an approximate 2
                                                                           second delay before the overload
                                                                           indicator light turns on and the
                                                                           alarm sounds.
                                                        9 Test all machine functions from the platform
                                                          controls.
                                                           Result: All platform control functions should not
                                                           operate.
                                                        10 Turn the key switch to ground control.
                                                        11 Test all machine functions from the ground
                                                           controls.
                                                           Result: All ground control functions should not
                                                           operate.
                                                                           Machine functions should still
                                                                           operate with auxiliary power at the
                                                                           ground controls.
Part No. 82682                               Service Manual Supplement                                        7
Maintenance Procedures                                             August 2003
MAINTENANCE PROCEDURES
12 Lift the test weight off the platform floor using a
   suitable lifting device.
    Result:
        The alarm should be off. The platform
        overload indicator light should be off at both
        the ground and platform controls.
        The alarm should be off. The platform
        overload indicator light should be off at the
        platform controls and there should be no
        error message on the LCD display at the
        ground controls.
                 There may be an approximate 2
                 second delay before the overload
                 indicator light and alarm turn off.
13 Test all machine functions from the ground
   controls.
    Result: All ground control functions should
    operate normally.
14 Turn the key switch to platform control.
15 Test all machine functions from the platform
   controls.
    Result: All platform control functions should
    operate normally.
                 If the platform overload system is
                 not operating properly, repeat
                 steps 1 through 4.
8                                    Service Manual Supplement   Part No. 82682