PN7004

Pressure sensor with display


PN-010-RBR14-QFRKG/US/ /V

phase-out article

Alternative articles: PN7094


When selecting an alternative article and accessories please note that technical data may differ!

1 alphanumeric display 4-digit


2 LEDs Display unit / switching status
3 programming button

Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Process connection threaded connection G 1/4 internal thread
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25...80
Min. bursting pressure 150 bar 2175 psi 15 MPa
Pressure rating 75 bar 1087 psi 7.5 MPa
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18...36 DC; (to SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN7004-03 — 30.10.2013 —
PN7004
Pressure sensor with display
PN-010-RBR14-QFRKG/US/ /V

Reverse polarity protection yes


Overvoltage protection yes; (< 40 V)
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching [V]
2
output DC
Permanent current rating of [mA]
250
switching output DC
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Measuring/setting range
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Set point SP -0.9...10 bar -12...145 psi -0.09...1 MPa
Reset point rP -0.95...9.95 bar -13...144 psi -0.095...0.995 MPa
In steps of 0.05 bar 1 psi 0.005 MPa
Factory setting SP1 = 2.50 bar rP1 = 2.30 bar
SP2 = 7.50 bar rP2 = 7.30 bar
Accuracy / deviations
Switch point accuracy
< ± 0,5
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
[% of the span]
Hysteresis deviation
< ± 0,25
[% of the span]
Long-term stability
< ± 0,05; (per 6 months)
[% of the span]
Temperature coefficient zero
point 0,2; (-20...80 °C)
[% of the span / 10 K]
Temperature coefficient span
0,2; (-20...80 °C)
[% of the span / 10 K]
Response times
Delay time programmable dS, [s]
0; 0,2...50
dr

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN7004-03 — 30.10.2013 —
PN7004
Pressure sensor with display
PN-010-RBR14-QFRKG/US/ /V

Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; diagnostic function;
switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs Type of operation DeviceID
default 311
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 65
Tests / approvals
EMC EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5/1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance DIN IEC 68-2-6 20 g (10...2000 Hz)
MTTF [years] 219
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 262.6
Materials stainless steel (304/1.4301); stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts) stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles 100 million
Process connection threaded connection G 1/4 internal thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display Display unit 3 x LED, green
switching status 2 x LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Remarks
Pack quantity 1 pcs.

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN7004-03 — 30.10.2013 —
PN7004
Pressure sensor with display
PN-010-RBR14-QFRKG/US/ /V

Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated

OUT1 switching output


IO-Link
OUT2 switching output
Diagnostic output

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN7004-03 — 30.10.2013 —