COMPANY NAME: DOCUMENT NO:

AHFA PRIVATE LIMITED COMPANY PL/AHFA/08


` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

Maintenance Plan
Description of Item Preventive maintenance Preventive measure Frequency
machinery no check list
code ½
day week month quarter year year
Unit1: .clean the panel & AVR .regularly dust the 
Panel Board with air &cloths exterior of the panel
and AVR &AVR with a soft
(Automatic cloth or brush
voltage .check all bus bar .to check the loose 
regulator) connection input &output connection
.check all circuit breakers .to check the loose 
input &output connections connection
.check any hot spot in .to stop overheating 
panel by ensuring
ventilation is not
obstructed
.check all measuring .to operate 
instruments according to load
.check all circuit breaker .to improve the shelf 
load according to capacity life of breaker
.check earth connection .to remove the shock 
with panel
.check any abnormal sound .to ensure the 
in panel normal operation
.check function of lamps & .to know the 
indicators working principles
.check general condition of .addressing design 
the device issues
.check function of all .to know the energy 
power meters before efficiency overall
shutdown

.check the emergency & .to ensure all 


exit lighting systems emergency lighting
fixtures are clean &
free from
obstructions

.Check that all labels are .to identify and label 


correct and in place each circuit breaker
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

. Check locking devices on .to replace by new 


electrical units for signs of
damage
.check alarms and remote .to know any 
alarm panels board problem will be
happen
Unit 2: .check the input & output . to ensure that the 
Boiler machine power connection power will be
available
.check all electrical .to adjust the 
equipment working equipment/replace it
properly
.check the water feeding . to restore/replace it 
pump

.check all electrical . to ensure the loose 


connections connection

.check gas oil feeding .to restore the 


pump pump/repair it

.check the rotational .to restore the 


direction of each pump direction

.check the emergency push .replace the new 


button
.check the utility pump . to restore the 
pump/repair it
Unit 3 : .check visual inspection .Verification that 
Light & switch the light & switch
are functional or not
.check function of all .energy efficiency 
power meters before over all
shutdown

.check to see that all .to the evidence of 


heaters are energized & working
operates functionally

.to the evidence of 


.Check cables & overheating &
connection weakening of the
insulation
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.check the wattage or .to replace the old 


luminous intensity of the one
light
.check the terminal boxes .to ensure the loose 
connection
.check the top lid cover for .to protect from any 
any damage dust or water for the
surface of top cover

.Check the rating power .to ensures that the 


rate is equal or
higher than the
switch
.the switch needs to 
.check the room operate in a constant
temperature & environment temperature & clean
environment

.check for dust & moisture .to improve the shelf 


life

.check the control power & .to prove the lamps 


brightness lose brightness over
time
.Check general condition .addressing design
of the device issues

. check for corrosion at the .to produce smooth 


terminals and correct
operation

.check the inspect locking .to replace the new 


devices for signs damage
or worn
Unit 4: .check the input & output .to ensure that the 
Bottle blowing power connection power will be
machine available
.check the main & all sub .to ensure the 
breaker are functional operation will be
functional
.check all fans work .to change the 
properly damage one
.check the rating voltage & . the rating is not 
current under or over the
nameplate
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.check the abnormal noise .to restore 

.check the heater .to change the new if 


there is not work
. check any hot spot in . to stop overheating 
panel
.check the emergency push .to the evidence of 
button switch work/replace it
.check each electrical . to ensure the loose 
connection connection
Unit 5: .check the input & output .to ensure that the 
Air power connection power will be
washer/filling available
machine .check each conveyor . to ensure that the 
power connection power will be
available
.check air inlets .evidence of damage 
caused by dirty,
loose part, or foreign
objects
. check the rating voltage . the rating voltage is 
not under or over the
nameplate

.check the rotation .to change the 


direction of each motor direction
.check the vibration & .to repair the shaft
temperature of dry motor alignment
. check visual inspection .verification that air 
inlet are not blocked
.check the level switch .to set the proper 
light indicator position
.check each push button .to the evidence of 
switch work
.check the air dry motor .over heat/block dust 

.check the power supply of .the input & output 


each driver power
.check the tunnel sterilizer .to solve if there is 
spry motor any problem
. check each motor .to replace the new 
rotation, fan cover & & clean the dust
bearing
.check the power supply of . to ensure that the 
laser machine & libeling power will be
machine available
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.check the conveyor motors .to inspect the belt 


are not over heat tension & the shaft
alignment
.check the spray pump .to repair the pump 
work properly
.check working of gearbox .to the evidence of 
motor working properly
. check all measuring . to operate 
instruments according to load

. Check cables & . to the evidence of 


connection overheating
Unit 6: . check the input & output to ensure that the 
Blending power connection power will be
machine available
. check visual inspection of . verification that air 
each pump inlet are not blocked
.check bearing and .to fill lubricant 
lubricant condition level, and vibration
. check the overall pump .Imminent bearing 
vibration failure can be
preceded by a
change in bearing
vibration

.check the discharge pump .to restore the pump 


pressure
.check the centrifugal .to its intended 
pump flow rate design performance
.check the discharging . to ensure the cool 
pump fan down
. check each mixer motor .to the evidence of
mixing properly
.check the cip pump .to ensure working 
properly
.check each circulation .to ensure the flow 
pump rotate direction
.check the power . to ensure the loose 
connection of the terminal connection
. check the oil analysis the . the oil level is not 
mixer motor under & not over
heat

. check the Rotor balance . Balance process 


minimizes the out of
balance of the rotor
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.check the vacuum pump .to restore the 


pump
.check the insulation .Perform IR check 
resistance between motor
leads and ground
. Stator visual Inspection . Coil movement 

.check the temperature .record bearing 


monitoring of bearings & temperatures &
windings stator temperature
using thermo-
graphic imaging
.check the vibration of .record & trend 
pump vibration levels

Unit 6: . check the input & output . to ensure that the 


TIT sterilizer power connection power will be
machine available
.check the discharging . to restore the pump 
pump
.check the rotor/Shaft . balance weights 
visual inspection properly secured
.check all electrical .to repair loose 
connection/motor connections
.check every shaft rotation .to repair the 
is normal alignment
.check cip turn back pump .to restore the pump 

. check the circulation .to restore the pump 


pump
.check each electrical .for the evidence of 
connections loose connection
Unit 7: . check the input & output . to ensure that the 
Ro water power connection power will be
treatment available
machine
. check the system .inspect & clean 
operations

.check water meter .record water
readings production

.check the pumping rate for .to repair with in a 


each nameplate
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.Clean pump house .the dust & mud 


with in air & cloth
.inspect for abnormal noise .to restore & repair 
the alignment

.check running amps on .to run the pump


pumps within the nameplate

.check the secondary . to restore the pump 


booster pump

. check the raw water pump .to restore the pump 

.check the high pressure .to restore the pump 


pump
.check all electrical .to repair loose 
connections connections

.check the sealing of the .to repair the new 


pump
.check the feeding pump .to ensure the work 

.check the high-water and .to repair the 


low-water alarms adjustment
.check the cip pump .to restore 

.check the secondary water .to restore the pump 


feed pump
Unit 8: . check the input & output . to ensure that the 
High & low power connection power will be
pressure available
compressor .check the running current .to adjust with the 
rating values
.check each electrical .repair the loose 
connections connection
.check the rotational .to restore the motor 
direction of motor direction
. check amps and voltage .to restore within the 
nameplate
. Check display readings .to adjust the real 
display
COMPANY NAME: DOCUMENT NO:
AHFA PRIVATE LIMITED COMPANY PL/AHFA/08
` MACHINERY AND EQUIPMENT PREVENTIVE REVISION NO:01 PAGE:
MAINTANANCE PLAN

.check the vibration of the .to restore/repair the 


screw motor damage
. Check temperature .to protect overheat

.check the selector switch .work functionally 

Unit 9: . check the input & output . to ensure that the 


Cooling tower power connection power will be
available
.check the circulation pump .to repair/restore the 
pump
.check the cooling fan . to repair/restore the 
motor

. check all electrical . to repair loose 


connections connections
.visual inspect the .to restore/repair it 
rotational direction
.check the push button .to repair the new 
switch