CH−1
CHARGING SYSTEM
CHARGING SYSTEM
CH−2
CHARGING SYSTEM − Precautions
PRECAUTIONS
1. Check that the battery cables are connected to the correct terminals.
2. Disconnect the battery cables when the battery is given a quick charge.
3. Do not perform tests with a high voltage insulation resistance tester.
4. Never disconnect the battery while the engine is running.
TROUBLESHOOTING
Problem Possible cause Remedy Page
Discharge warning Fuse blown Check ”IGN” fuse
light does not come Light burned out Replace light
on with ignition ON Wiring connection loose Tighten loose connections
and engine off IC regulator faulty Replace IC regulator
CH−6
Discharge warning Drive belt loose or worn Adjust or replace drive belt CH−3
light does not go off Battery cables loose, corroded or worn Repair or replace cables
with engine running Fuse blown Check ”ENGINE” fuse
(battery requires frequent Fusible link blown Replace fusible link
recharging) IC regulator or alternator faulty Check charging system
CH−4
Wiring faulty Repair wiring