OPERATING MANUAL

ED640 Instrument

Elettrondata srl
Via del Canaletto 77/79
41042 Spezzano di Fiorano
( Modena ) Italy
Tel. +39 0536 1840500
Fax. +39 0536 1840501
www.elettrondata.it
info@elettrondata.it

Version 1.8.3 of 05/09/2012


2 ED640 Instrument

Summary
Part I General Informations 4
1 Introduction ...........................................................................................................4
2 Handbook Revisions...........................................................................................................4
3 Declaration of conformity
...........................................................................................................5
Part II Technical data 6
1 Technical Characteristics
...........................................................................................................6
Part III Simbology 7
1 Use of the instrument...........................................................................................................7
2 Maintenance ...........................................................................................................8
3 Disposal ...........................................................................................................9
Part IV Put in operation 10
1 Installation ...........................................................................................................10
2 Panels and Keyboard
...........................................................................................................11
2.1 Display visualizations
........................................................................................................13
3 Connections ...........................................................................................................14
Part V Basic Functions 15
1 FUN-0 ...........................................................................................................16
2 FUN-3 ...........................................................................................................17
3 FUN-4 ...........................................................................................................17
4 FUN-5 ...........................................................................................................18
4.1 CAL-0 ........................................................................................................19
4.2 CAL-1 ........................................................................................................19
4.3 CAL-2 ........................................................................................................20
4.4 CAL-3 ........................................................................................................20
4.5 CAL-4 ........................................................................................................21
4.6 CAL-5 ........................................................................................................21
4.7 CAL-6 ........................................................................................................21
4.8 CAL-7 ........................................................................................................22
4.9 CAL-8 ........................................................................................................22
4.10 CAL-9 ........................................................................................................22
4.11 CAL-A ........................................................................................................23
4.12 CAL-B ........................................................................................................23
4.13 CAL-C ........................................................................................................24
4.14 CAL-F ........................................................................................................24
5 FUN-6 ...........................................................................................................25
6 FUN-8 ...........................................................................................................25
7 FUN-9 ...........................................................................................................26
7.1 eCal-1 ........................................................................................................26
7.2 eCal-2 ........................................................................................................27
7.3 eCal-5 ........................................................................................................27
7.4 eCal-6 ........................................................................................................28

© 2012 ELETTRONDATA S.R.L.


Summary 3

7.5 eCalibration ........................................................................................................28


8 FUN-A ...........................................................................................................29
9 FUN-B ...........................................................................................................29
10 FUN-D ...........................................................................................................30
11 FUN-E ...........................................................................................................30
11.1 IN ........................................................................................................31
11.2 DEF ........................................................................................................31
11.3 TST ........................................................................................................32
11.4 OUT ........................................................................................................32
11.5 SER ........................................................................................................32
11.6 ETHERN ........................................................................................................33
11.7 RTC ........................................................................................................34
11.8 NOISE ........................................................................................................35
11.9 GRAVIT ........................................................................................................35
Part VI Operating Modes 36
Part VII Calibration 36
1 Thresholds ...........................................................................................................37
2 Stable weight ...........................................................................................................38
3 Zero-setting device ...........................................................................................................38
3.1 Tare device ........................................................................................................38
3.2 Semi-Automatic Zero-Setting
........................................................................................................39
3.3 Suppression of negative
........................................................................................................39
4 Zero-tracking ...........................................................................................................39
Part VIII Messages 40
Part IX Compliance Statement 41
Part X General Conditions 48
Part XI Support 49
Part XII Annex A 50
1 Annex A1 ...........................................................................................................51
Part XIII Annex B 52
Part XIV Annex C 53
Part XV Counter Function 56
Index 57

© 2012 ELETTRONDATA S.R.L.


4 ED640 Instrument

1 General Informations

WARNING!
READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO ANY OPERATION, ON
THE SYSTEM, OF INSTALLATION, USE OR MAINTENANCE. THIS MANUAL CONTAINS
DATA AND INSTRUCTIONS FOR USE RELATED TO THE EQUIPMENT PROVIDED IN
THE MAXIMUM CONFIGURATION, THEREFORE REFERENCES TO FUNCTIONS NOT
PROVIDED OR ACCESSORIES AND NOT SUPPLIED IN YOUR SYSTEM, SHOULD BE
IGNORED.
This manual, which is to be considered for all purposes an integral part of the equipment, along with
information for proper use, contains information essential to ensure the safety of persons involved in
the use, it is therefore essential that all those who using the instrument ED640 will read carefully the
content.
FOR THE PURPOSE OF IMPROVING THE PRODUCTION FROM A TECHNOLOGICAL POINT OF VIEW, THE
COMPANY RESERVES THE RIGHT TO MODIFY ITS PRODUCTS WITHOUT NOTICE AT ANY MOMENT.

1.1 Introduction
This manual describes the proper ways of installation, use and maintenance of the instrument ED640.
This instrument is the expression of the most advanced electronic technology applied to control the amount of
product to be dosed in the plant for concrete production. Designed using the experience gained through many
years of production of control equipment, the instrument was designed to solve the problems that continued
evolution of technology suggests. The realization of the instrument conforms to the type of use, considering
the harsh environments in which it operates. To allow this, and at the same time achieve high quality
assurance, reliability and immediate retrieval of parts, has introduced a new concept for developing the system
very innovative for this type of application. In the event of damage or accidental alteration of data they can be
recharged in minutes via an automatic installation procedure. Using the above techniques you can make
changes to the operation of the instrument, update the program with new versions automatically without having
to intervene in any electrical part of the plant. In this way the tool can use the work programs are constantly
updated according to developments in the technology sector, without changing the mode of operation of
employees, saving for acquiring new work methods.
Considering the great potential of the instrument is possible to implement with programs or other
electromechanical provided by third parties. The instrument can be installed on newly installed power plants
that exist in the latter case without any intervention in the control cabinet. Furthermore the instrument is
capable of recording (for purposes of production control) everything is determined by the product it is
connected.
If discrepancies arise between the ordinary functioning, described in the manual, and the
actual operation of the system, please contact the Customer Support.

WARNING
Read carefully and adhere strictly to the instructions in this manual! Only in this way you can learn the proper use of the
instrument ED640 and avoid risky situations, so follow the safety rules and keep this guide handy.

1.2 Handbook Revisions


REVISION DATE DESCRIPTION
1.8 03/12/10 Added modify to FUN-0; CAL-0;
1.8.1 11/10/11 Chapters revision as technical specifications
1.8.2 11/05/12 Added annex A1
1.8.3 10/08/12 Added annexes D, D1, D2, D3 e D4

© 2012 ELETTRONDATA S.R.L.


General Informations 5

1.3 Declaration of conformity

© 2012 ELETTRONDATA S.R.L.


6 ED640 Instrument

2 Technical data
VIEWER INSTRUMENT FOR QUANTITY OF PRODUCT.
DIMENSIONS Length 91 mm; Height 44 mm; Width 138 mm.
ASSEMBLY On an electromechanical control panel able to the management of the plant.
OPENING IN PANEL Length 92 mm; Height 45 mm. See Panels and Keyboard
POWER SUPPLY 110/230 Vac by VDE cable.
TOTAL ABSORPTION 0,05 VA
ANALOG POWER SUPPLY 5,000 Vdc ±2% 120mA (max Eight of 350 Ohm), with short circuit protection.
DISPLAY DIVISIONS 3000 for metric instrument, expandable till to 100.000 for non metric use.
MIN POWER PER DIVISION 0.75 µ V (homologated instrument); 0.03 µ V (not homologated instrument).
ANALOG INPUTS 1 - Load cells input or 1 - potentiometer input or 1 - 0-10 V input.
NPN or PNP DIGIT. INPUTS 2 - photocoupled inputs, max 24 Vdc.
RELAYS OUTPUTS 2 - relays contacts outputs, max 230Vac, with a single common.
16BIT ANALOG OUTPUTS 1 - 0-10 V output (2-10 V optional) or 1 - 0-20 mA output (4-20 mA optional).
SERIAL OUTPUTS One configurable bidirectional port RS232/RS485 to connect with PC or PLC.
SCALES DISPLAY Six digits with 7-segment displays.
INDICATIONS Six LED status indicators, including the thresholds.
NEGATIVE READING Minus Signe (-). See also Display visualizations
KEYBOARD Five Tactile Switches.
CALIBRATION METHOD By keyboard or via software: TrWin or another management plant software.
OPERATING TEMPERATURE From 14°F to 104°F

INTEGRATIONS TO THE CONFIGURATIONS


MANAGEMENT OF THE ETHERNET INTERF. for dialogue with PC to manage its parameters and statistics.
MANAGEMENT OF AN ALIBI MEMORY, to tracking the dosed for the balance associated with the instrument.
MANAGEMENT OF A CHECKSUM ON SERIAL INTERF. for data communication with other serial instruments.
MANAGEMENT OF WEIGHING SYSTEMS with METROLOGICAL HOMOLOGATION.

2.1 Technical Characteristics


Instrument ED640 sampling a signal from:
1. by a load cell (ED640 / 1);
2. by a potentiometric transducer (ED640 / 2);
3. by a signal 0-10V (ED640 / 4);
It can also function as a counter (ED640 / 6).
The value of the sampling is displayed according to the setup and the calibration parameters stored in the
installation phase of it. The instrument is able to provide the value sampled by:
an analog output proportional to the full scale value set.
a serial selectable between RS232 and RS485.
the Ethernet interface.
The instrument provides a voltage of 5 Vcd ± 1% that can power the load cells, the potentiometer, draw from
pin 4 (GND) and pin 3 (+5 Vdc) of the 9-pin female connector.
The instrument has two programmables thresholds of minimum and maximum, made via two relay contacts
and visualized in the front panel via two LED's and . The threshold of maximum is used as an
alarm output under these conditions:
1. At the Switch on, the contact remains closed until initialization of the parameters.
2. At the occurrence of an anomaly, appears to display the symbol ERRxx. Refers to Messages.
3. Entering the configuration that changes the parameters of connection with the field.
Instrument ED640 has a main page, those in current use, to visualize the value of the sampling and more
pages for the calibration and setting of the instrument. Some of these (approved version with metrological
certificate) are accessible only by qualified personnel in possession of passwords.

© 2012 ELETTRONDATA S.R.L.


Simbology 7

3 Simbology

Read this manual carefully, before attempting to install the instrument ED640.
The instrument is covered by WARRANTY therefore SHOULD NOT BE COMPROMISED for any reason,
any attempt occurred on the instrument will cancel any condition of warranty. Every problem has occurred with
the instrument or the system connected to him shall be communicated to the supplier or dealer or service
center where it was purchased.
This manual brings informations for the end user and the technician of the different operation modes of the
instrument, both in the approved version with metrological certificate and in the not approved version, the
functions of keys and the indications on the display.
The end user who found, while reading, the words: "REPOR.TECH.PERS." knows that is being described
an advanced function, reported to technical personnel, and it will be deepened in this manual.
This manual was edited by paying attention to errors, eventually, any reports of inaccuracies are always
accepted.

3.1 Use of the instrument


IMPROPER USES OF THE INSTRUMENT

WHERE OTHERWISE INDICATED, THIS DOES NOT HAVE WEIGHTS AND MEASURES
DEPARTMENT APPROVAL.
IT IS NOT A DESKTOP INSTRUMENT; IT FORMS PART OF AN ELECTROMECHANICAL AND
ELECTRONIC LOGIC SYSTEM DESIGNED FOR CONTROL AND MANAGEMENT OF AN INDUSTRIAL
PLANT. IT IS INTENDED FOR PROFESSIONAL USE.
DO NOT USE THE INSTRUMENT FOR ESTABLISHING WEIGHTS FOR COMMERCIAL
TRANSACTIONS, FOR CALCULATING A HIRE CHARGE, FOR THE APPLICATION OF STATUTORY OR
REGULATORY REQUIREMENTS, IN MEDICAL PRACTICE, FOR THE MANUFACTURE OF MEDICINES,
OR FOR CALCULATING PRICES ON THE BASIS OF WEIGHT.
DO NOT USE THE INSTRUMENT FOR THE DIRECT OPERATION OF MACHINERY IN MOTION UNLESS
THE MACHINERY IS EQUIPPED WITH ITS OWN EMERGENCY AND SAFETY DEVICES AND
UNDERGOES REGULAR INSPECTIONS BY THE STAFF ASSIGNED.
DO NOT USE IN AN EXPLOSIVE ATMOSPHERE.
DO NOT TAMPER WITH THE INSTRUMENT: CALL IN THE SUPPLIER OR SKILLED STAFF FOR
REPAIRS. IN CASE OF TAMPERING, WARRANTY COVER IS FORFEITED AND THE MANUFACTURE
DOES NOT ACCEPT LIABILITY FOR ANY INJURY OR DAMAGE.
ALL IMPROPER USE IS FORBIDDEN: THE MANUFACTURER DOES NOT ACCEPT LIABILITY IN THE
EVENT FO USE OF CONTRAVENTION OF THE RELEVANT STATUTORY REQUIREMENTS

TRASPORT AND STORAGE


The instrument must be transported and stored with great care.
The instrument and packing do not withstand hard knocks.
The manufacturer cannot be held responsible for damages due to the incautious handling.
Keep dry packing and instrument.
The manufacturer cannot be held responsible for damages due to the careless.
The packing materials are plastic and cardboard box.
Dispose following the regulations in force.
The instrument has to be disposed as indicated in paragraph: DISPOSAL.

© 2012 ELETTRONDATA S.R.L.


8 ED640 Instrument

ENVIRONMENTAL CONDITIONS OF USE


For industrial uses : -10°C to +40°C KEEP AWAY FROM SOURCES OF HEAT
Use in protected environments: KEEP AWAY FROM DIRECT
Relative humidity without condensation : 20% to 80%. KEEP DRY THE INSTRUMENT

POWER ON
The instrument just lit displays, before the measured value of weight:
The types; i.e. ED640.1; ED640.E (explained in the following in the manual)
The software release; i.e. r7.00 (different number if you are using the homologable version)
The software Checksum; i.e. c9290 (different number if you are using the homologable version)
The tests of LEDs and display;
The value of GRAVITY set; i.e. 9.80655
and written Init ...
If you notice any abnormalities at this stage, power OFF and ON the instrument, if those recur contact the
Customer Support.

3.2 Maintenance
WARNING!

DO NOT TAMPER THE INSTRUMENT


CONTACT THE SUPPLIER OR SERVICE-TRAINED AND CERTIFIED BY HIM FOR MAINTENANCE. In case
of tampering the WARRANTY will void and the company manufacturer is not liable for any damage to things or
people or animals.

USE ONLY GENUINE PARTS


CONTACT THE SUPPLIER OR SERVICE-TRAINED AND CERTIFIED BY HIM FOR SPARE PARTS. To
prevent to void the WARRANTY and possible anomalies, for which the company manufacturer is not liable for
any damage to things or people or animals.

REMOVE THE POWER SUPPLY TO THE INSTRUMENT


CONTACT THE SUPPLIER OR SERVICE-TRAINED AND CERTIFIED BY HIM BEFORE MAKING ANY
MAINTENANCE. To prevent to void the WARRANTY and possible anomalies, for which the company
manufacturer is not liable for any damage to things or people or animals.

USE THE INSTRUMENT ONLY IN A HEAVY INDUSTRIAL ENVIRONMENT


CONTACT THE SUPPLIER OR SERVICE-TRAINED AND CERTIFIED BY HIM, TO OBTAIN MORE
INFORMATIONS. The selling company is not liable for any damage to property or persons or animals caused
by carelessness or rough manipulation, handling or installation of the instrument.

DO NOT USE THE INSTRUMENT IN EXPLOSIVE ATMOSPHERE


CONTACT THE SUPPLIER OR SERVICE-TRAINED AND CERTIFIED BY HIM, TO OBTAIN MORE
INFORMATIONS. The selling company is not liable for any damage to property or persons or animals caused
by carelessness or rough manipulation, handling or installation of the instrument.

© 2012 ELETTRONDATA S.R.L.


Simbology 9

DO NOT CLEAN THE MASK OF INSTRUMENT WITH CHEMICAL AGENTS


Use a cloth lightly moistened with water. The selling company is not liable for any damage to property or
persons or animals caused by carelessness or rough manipulation or handling of the instrument.

NOT USE POINTY THINGS


ON KEYS OR ON CABLES CONNECT TO THE INSTRUMENT. The selling company is not liable for any
damage to property or persons or animals caused by carelessness or rough manipulation or handling of the
instrument.

PERIODICALLY CHECK THE INTEGRITY


OF THE INSTRUMENT AND OF THE CABLES CONNECTED TO THE SAME. The selling company is not
liable for any damage to property or persons or animals caused by carelessness or rough manipulation or
handling of the instrument.

DO NOT USE WATER FOR EXTINGUISHING FIRES


POSSIBLY CAUSED IN THE VICINITY OF THE INSTRUMENT. The selling company is not liable for any
damage to property or persons or animals caused by carelessness or rough manipulation or handling of the
instrument.

DO NOT USE FLAME FREE


CLOSE THE INSTRUMENT. The selling company is not liable for any damage to property or persons or
animals caused by carelessness or rough manipulation or handling of the instrument.

DO NOT MAKE A MAINTENANCE MECHANICAL PARTS


CLOSE THE INSTRUMENT WORKING WITHOUT REMOVING THE POWER SUPPLY. The selling company
is not liable for any damage to property or persons or animals caused by carelessness or rough manipulation
or handling of the instrument.

MAKE SURE THAT ALL THE LABELS ARE PRESENT AND READABLE;
OTHERWISE, PLEASE CONTACT THE SUPPLIER FOR OBTAIN SPARE PARTS.

3.3 Disposal
PUTTING OUT OF ORDER
1. Disconnect power supply to the part where the instrument resides.
2. Open the door of the electrical panel where the instrument is mounted.
3. Remove the power supply connector of the instrument.
4. Remove all connectors, present on the instrument.
5. Disassemble the instrument from the electrical panel, through a specific tool.
6. Cover with polyethylene air bubbles film (PLURIBOL) to avoid cuts or scratches to the front panel and
protect with cardboard box.
7. Dispose of it or returning to the company supplier, as shown below.

© 2012 ELETTRONDATA S.R.L.


10 ED640 Instrument

This symbol appears on the product indicates that belongs to the category WEEE stands for Waste from
Electrical and Electronic Equipment. The AEE are equipments that for proper operation depends on energy
supply, both as a user, either as generators, designed to operate at voltages to 1000 VAC or 1500 VDC and
should not be disposed of as urban waste. Users have to dispose the equipment to be scrapped, to the place
of collection indicated for the recycling of EEE.As in WEEE Directives: 2002/95/EC, 2002/96/EC e 2003/108/EC
and WEEE Decrees: legislative decree July 25, 2005, n.151; legislative decree April 03, 2006, n.152 and
ministerial decree June 18, 2010, n.65. For more information on the collection points for equipment to be
scrapped, contact in their home community, the local waste disposal service.

4 Put in operation
Before being operational, the instrument ED640 must be adapted to the characteristics of the plant.

For this purpose, some functions are provided to allow to do this directly by keyboard or by appropriate
software via serial connection. So it is very important that the first time or at the start-up, it be performed the
following sequence of operations:

Read the GENERAL CONDITIONS of warranty and liability.


Make connections as per schematic attached to the ELECTRICAL PANEL or in CONNECTIONS.
Insert the correct parameters follows the list in BASIC FUNCTION.
Make the CALIBRATION for the type of input and analog output.

4.1 Installation

"REPOR.TECH.PERS."
THE DESCRIBED OPERATIONS SHOULD BE MADE ONLY BY QUALIFIED PERSONNEL.
BEFORE STARTING WORK, CHECK THE CONFORMITY OF THE FUNCTIONING: THE
MANUFACTURER DISCLAIMS ANY RESPONSIBILITY FOR THE FAILURE OR INCORRECT
PRODUCTIONS OR ANY OTHER MALFUNCTION.

ASSEMBLY INSTRUMENT ED640

Fasten the instrument with the appropriate support on the door or on the synoptic of a electric panel and
connect the cables to the input connectors as per section Connections.
Avoid mounting in difficult situations, with unstable or vibration that may prevent the proper operation of the
instrument.
MAKE SURE THE APPLIANCE IS CONNECTED TO GROUND WIRE OF THE INDUSTRIAL PLANT.
AVOIDED TO COMPRESS THE CABLES CONNECTED TO THE DEVICE.
AVOIDED TO JUXTAPOSE SIGNAL CABLES AND POWER CABLES. Keep always separate conduits.
FASTEN THE INSTRUMENT IN A POSITION THAT ALLOWS PERFECT VISIBILITY OF THE PLANT, to
avoid starting the dosage in critical or danger conditions.
PROVIDE FOR AN ADEQUATE SYSTEM OF VENTILATION AND LIGHTING.
UTILIZE CONTINUITY GROUPS AS A FILTER, IF THE POWER SUPPLY COMES FROM AN POWER
GENERATOR OR ELECTRIC NETWORK WITH MANY CHANGES OF TENSION.
DO NOT INSTALL THE DEVICE NEAR INVERTER, MOTOR DRIVE OR OTHERWISE. Those must be
provided of neccessary electrical network filter.
USING FILTERS "RC" ON THE REEL OF ALL THAT DEVICES (CONTACTORS, SOLENOID VALVES,
RELAYS, ETC.) THAT COULD GENERATE NOISES.
IF EVENTUALLY EXIST A PHENOMENON OF CONDENSATION INSIDE THE DEVICE IS ADVISABLE TO
KEEP IT POWERED CONTINUOUSLY.
THE ELECTRICAL PROTECTION FOR INSTRUMENTS (fuses, circuit breaker door locks, etc.) ARE
PROVIDED BY THE INSTALLER OF THE ELECTRICAL PANEL.
DO NOT INSTALL IN HARSH ENVIROMENTS: WITH DUST, WITH STEAM ACIDS OR AT RISK OF
EXPLOSION.

© 2012 ELETTRONDATA S.R.L.


Put in operation 11

ASSEMBLY LOAD CELLS

MAKE SURE THAT THE MOUNTING OF CELLS ARE COMPLIANCE WITH EXISTING RULES AND THE
RULES HITHERTO.
VERIFY THAT THE STRUCTURE WHERE ARE MOUNTED THE CELLS IS PROPERLY LEVELED AND
RESTS ON A STABLE SURFACE.
CHECK THAT THE EARTH IS THE SAME STRUCTURE OF ELECTRICAL ORDER TO AVOID
DANGEROUS NOISE VOLTAGE OR FLOATING.
USE OF JUNCTION BOX ADJUSTED TO THE ENVIRONMENT INSTALLATION OF CELLS.
IN ENVIROMENTAL CONDITIONS UNFAVORABLE USING CABLE, SHEATH AND FITTINGS FLUE FOR
THE CABLES OF THE LOAD CELL AND CONNECTING TO THE ELECTRICAL PANEL.
CONNECTING THE CABLE FROM JUNCTION BOX TO ELECTRICAL PANEL MUST ALWAYS BE
SHIELDED AND PROTECTED BY GROOVES, ALSO OF METAL, AND KEPT AWAY FROM POWER
CABLES.
DO NOT PASS NEAR MOVING PARTS OR DANGEROUS SITUATIONS THAT COULD DAMAGE THE
SAME CABLE.
INSIDE THE ELECTRICAL PANEL, THE CABLE OF CELLS SHOULD NOT BE PUT IN CONDUIT WITH
OTHER CABLE BUT MUST MAKE A SELF-TRAIL, EVEN WITHIN ITS GROOVES, UNTIL THE
INSTRUMENT CONNECTOR.
ANY USE OF SIGNAL AMPLIFIERS, MUST FOLLOW THE SAME CONDITIONS DESCRIBED FOR LOAD
CELLS: SHIELDED CABLE, CASSETTE, PIPES AND FITTINGS PONDS.

WARNING!
Equipment under tension, do not intervene unless you are technical personnel, authorized to operate
on electrical installations.

STARTING
The instrument has a VDE connector and supports a power supply from 110 Vac to 230 Vac from electrical
network and it can be provided by a standard VDE cable.

ARREST
Remove tension through electromechanical protection (device breaker) or unplug the VDE cable input to the
instrument.

4.2 Panels and Keyboard


FRONT PANEL (if the instrument is METRIC)

© 2012 ELETTRONDATA S.R.L.


12 ED640 Instrument

FRONT PANEL (if the instrument is NOT METRIC)

BACK PANEL

BACK PANEL (if the version of instrument is Easy)

DRILLING TEMPLATE

92X45

© 2012 ELETTRONDATA S.R.L.


Put in operation 13

LEDS DESCRIPTION

Indicates that the value has fallen below the S1 minimum threshold setting.
Indicates that the measured weight is stable. It allows the automatic or manual operations
on ED640.
Indicates that the measured weight is near zero, in the range +/- ¼ of the division.
Indicates that the weight displayed is a net weight. Turned on after a manual tare.
Indicates that the value displayed is not a weight.
Indicates that the value has exceeded the S2 maximum threshold setting.

KEYS DESCRIPTION

ARROW UP key, if maintained pressed and if the conditions exist, executes the semi-
automatic zero-setting.

ARROW DOWN key, if maintained pressed and if the conditions exist, executes the manual
tare.

ENTER key, for confirmation or if maintained pressed allows the setting of the minimum
threshold.

ESC key, to exit or when maintained pressed allows the setting of the maximum threshold.

Hidden Key, if maintained pressed between the word Init..., till the request of a password,
allows entry into the otherwise hidden configuration menus (highlighted in red in the
manual).

4.2.1 Display visualizations


The display features two views that immediately identify as many problems.

When the low segments are lit on means that the weight is of 20 divisions below compared to zero (TARA)
Calibration. Example: If a division corresponds to 1 kg instrument can display till to -20 kg and when is just
over that weight the display visualize as image:

When the high segments are lit on means that the weight is in excess of 9 divisions with respect to Full Scale
set. Example: If a division corresponds to1 kg the instrument, with full scale 300 Kg, can display till to 309 Kg
and when is just over that weight the display visualize as image:

© 2012 ELETTRONDATA S.R.L.


14 ED640 Instrument

These two views remain until restored to normal weighing. If they were to intervene quite frequently, please
check the setup data of the instrument, the connections of the cells and the mechanical structure.
Even the communication protocols to transmit outside these two conditions:
1) When you are above the full scale, transmit +-----
2) When it is below the Tara transmit ------

"REPOR.TECH.PERS."
This mode is compliant with OIML R76-1: 2006 (E) section 4.2.3

4.3 Connections

The connectors on board the instrument have the connections as shown on the label and as described below.

INPUT SIGNAL
To connect the 6-wire load cells (see the annex A) use the following pins on the 9-pin connector:

PIN 1 SIG-; Negative signal of the load cells.


PIN 2 SIG+; Positive signal of the load cells.
PIN 3 EXC+; Positive power supply of the load cells.
PIN 4 EXC-; Negative power supply of the load cells.
PIN 5 SENS+; Positive SENSE signal of the load cells.
PIN 8 SENS-; Negative SENSE signal of the load cells.

To connect the 4-wire load cells use the following pins on the 9-pin connector:

PIN 1 SIG-; Negative signal of the load cells.


PIN 2 SIG+; Positive signal of the load cells.
PIN 3 EXC+; Positive power supply of the load cells.
PIN 4 EXC-; Negative power supply of the load cells.

To connect a potentiometric transducer use the following pins on the 9-pin connector:

PIN 3 EXC+; Positive power supply of the potentiometric transducer.


PIN 4 EXC-; Negative power supply and negative signal of the potentiometric transducer.
PIN 9 POT; Positive signal of the potentiometric transducer.

© 2012 ELETTRONDATA S.R.L.


Put in operation 15

To connect an 0-10 Vdc analog signal use the following pins on the 9-pin connector:

PIN 4 EXC-; Negative signal from an analog 0-10 Vdc .


PIN 7 0-10V in; Positive signal from an analog 0-10Vdc.

To use the reading of digital pulses refer to COUNTER FUNCTION.

OUTPUT SIGNAL
To use the analog output use the following pins on the 9-pin connector:

PIN 4 EXC-; Negative signal of the analog output.


PIN 6 AOUT; Positive signal analog 0-10 Vdc (2-10 Vdc optional) or 0-20 mA (4-20 mA optional).
Refer to the parameter in FUN-E for the choice of the analog output.

To use the RS232 serial link, connect the terminals of the 8-pin orange connector:

TERMINAL 4 TX/-; Signal transmission of data to the instrument.


TERMINAL 5 RX/+; Signal receiving data from the instrument.
TERMINAL 6 gnd; Signal ground of the serial for the instrument.

To use the RS485 serial link (see the annex A), connect the terminals of the 8-pin orange connector:

TERMINAL 4 TX/-; Negative signal o B of the instrument.


TERMINAL 5 RX/+; Positive signal o A of the instrument.

Note: the RS485 link must be terminated with a resistor 220 Ohm 1/4 W on the connector of the last
instrument.

To use the Ethernet connection to connect a standard cable into the ETHERNET connector:

1) Patch cable for connection to PC / PLC via the network switch.


2) cross cable for direct connection between the instrument and the PC / PLC.

For the two thresholds of min. and max. connect the terminals of the 8-pin orange connector:

TERMINAL 1 ; Minimum threshold of the instrument.


TERMINAL 2 COM; Common of thresholds of the instrument.
TERMINAL 3 ; Maximum threshold of the instrument.
TERMINAL 2 COM; Common of thresholds of the instrument.
The maximum threshold is used, connected to a sounds or lightings device, as signs of abnormal conditions.

5 Basic Functions
With instrument in power on, pressing simultaneously the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the menu function, described below. It is also turned on the F Led for indication that
is a FUNCTION, so not a measured quantity but a generic numeric value. If you press the press (Enter) key
on a not used function, the instrument returns in view mode. Use the (arrow up) and (arrow down) keys
to select functions to visualize or modify. With the ESC key returns to the previous menu without storing any
data changed, till returning in view mode. Also if no buttons are pressed for 10 seconds, comes back in view
mode. With the (enter) key, stores the data displayed and returns to the previous menu.

FUNCTION KEYS DESCRIPTION

FUN-0 SETTING PARAMETERS FOR ALIBI MEMORY


FUN-1 NOT USED
FUN-2 USED ONLY IN COUNTER CONFIGURATION TO RESET THE COUNTER.
FUN-3 VISUALIZATION OF THE COUNTER OF THE ACCESS INTO THE PROTECTED MENUS.
FUN-4 SETTING OF THE TARA MANUAL, will appear in the menu FUN-5 - CAL-C.

© 2012 ELETTRONDATA S.R.L.


16 ED640 Instrument

FUN-5 SETTING PARAMETERS FOR THE CALIBRATION OF THE INSTRUMENT.


FUN-6 SETTING OF THE DATUMS FOR ALIGNMENT OF THE ANALOG OUTPUT.
FUN-7 NOT USED
FUN-8 SETTING OF THE DATUM FOR THE ADJUSTMENT OF THE VALUE OF GAIN.
FUN-9 SETTING PARAMETERS FOR eCAL
FUN-A SETTING OF THE DATUMS FOR THE PARAMETRIC CALIBRATION OF LOAD CELLS.
FUN-B SETTING TO EXECUTE THE PRECALIBRATION OF LOAD CELLS.
FUN-C NOT USED
FUN-D VISUALIZATION OF THE SERIAL NUMBER OF THE INSTRUMENT.
FUN-E SETTING PARAMETERS FOR THE FUNCTIONING OF THE INSTRUMENT.
FUN-F NOT USED

DESCRIPTION OF THE PARAMETERS IN THE FUNCTION MENUS


Following are explained all the parameters of this instrument that you can access and modify.

"REPOR.TECH.PERS."
In case you want to access in the protected menus (shown in red, in this manual) of the instrument, in the
approved version with metrological certificate, follow the directions below:

POWER-ON with Hidden key pressed.


INSERT THE PASSWORD: N=... See the Annex D, D1, D2, D3 and D4 or contact the Customer Support.
Enters in the PROTECTED menus.ALL MENU IN RED ARE ENABLED.

NOTE: To exit, turn off the instrument. The number of accesses in protected areas is viewable in FUN-3. No
one can reset this counter.

5.1 FUN-0
To set the parameters for the ALIBI MEMORY, from FUN-0 menu press (Enter) key.

FUN-0
READ ALLOWS TO READ THE STORINGS OF THE ALIBI MEMORY
REWRITE INSERT A VALID REWRITE NUMBER.
ID INSERT A VALID ID NUMBER, IF IT IS NOT CORRECT, VISUALIZE NOREC.
If Rewrite id is correct
NET NET WEIGHT
GROSS GROSS WEIGHT
TARE TARA WEIGHT (if press TARA key or via communication protocols)
PRESET TARE TARA WEIGHT (if insert a value by FUN-4 menu or via communication protocols)
DATE ACQUISITION DATE (if enabled)
TIME ACQUISITION TIME (if enabled)
CONFIG
DATE Storing the acquisition of date and time, of the datum for that extraction.
NODATE Memorize ONLY the values, in weight, for the extraction.
ERASE

Within this function can be view the recordings made (ONLY WITH STABLE WEIGHT) from the ALIBI
MEMORY for each extractor that makes a weighed in the scale that is associated with this instrument.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 17

"REPOR.TECH.PERS."
Present only in the homologable version of the instrument, if at the power ON appears ED640.1 or ED640.E,
this feature is not active. To access to the parameters of ALIBI MEMORY, you must enter in the protected
menu following the correct procedure, otherwise the instrument comes back to FUN-0. Press simultaneously
the (arrow up) and (arrow down) keys and the (enter) key, you enter into the FUN-0 menu and pressing
the (Enter) key. From the READ menu by pressing the (Enter) key request the REWRITE number, that is
normally a three digits value (it could be 5 digits if mounted the second memory) and is the number of memory
completement, pressing the (Enter) key request the ID number, that is normally a six digits value (it could be
10 digits if mounted the second memory) and is the number of storage you want to see. Once inserted, press
the (Enter) key.
If the number is not correct appears NOREC, if it is the correct you can enter into the storage and are
displayed:
NET, after two seconds the value of the net weight for the extract weighed, to continue press the (Enter) key.
GROSS, after two seconds the value of the gross weight for the extract weighed, to continue press the
(Enter) key.
TARE, after two seconds the value of the quantity zeroed by pressing the TARA key or via communication
protocols.
PRESET TARE, after two seconds the value of the quantity zeroed by set a value in FUN-4 or via
communication protocols.
DATE, after two seconds, the value of the date on which the extract weighed was taken, to continue press the
(Enter) key.
TIME, after two seconds, the value of the time on which the extract weighed was taken. To exit, press the ESC
key.

Also are enabled the two menus in red.


CONFIG allows you to set the method of storing the data.
a) Includes the date and time. The Available storings for NODATE setting are 261632.
b) Only the weight values. Available storings for DATE setting are 174421.
ERASE allows the cancellation of all ALIBI MEMORY.
This memory is circular so when the recordings are finished, is increased the value of REWRITE and the
subsequent storages overwrites the first records made from the instrument. Therefore it is essential to know
the exact values of the REWRITE and the ID to read the correct data.

5.2 FUN-3
To view the value of the CALIBRATIONS COUNTER, from the FUN-0 menu, with the (arrow up) key,
search FUN-3 and press (Enter) key.

FUN-3
nnnn Unchangeable value

In this function it displays a counter that is incremented each time that are changed the parameters of
calibration or linearization or it is executes an access onto the protect menus.

"REPOR.TECH.PERS."
To access to the FUN-3 menu, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-3 and pressing the
(Enter) key.

This counter can not be altered or deleted by the user.

5.3 FUN-4
To set the parameters for the MANUAL TARE, from the FUN-0 menu, with the (arrow up) key, search FUN-
4 and press (Enter) key.

© 2012 ELETTRONDATA S.R.L.


18 ED640 Instrument

FUN-4
TARE If exist the possibility is executed the manual tare.
nnnn Insert by the keyboard, the value of weight to remove from the visualisation.

This function does not move the full scale but works within it, showing the negative value till the Tara value,
setted with CAL-5. Everything will turn off when the weight drops to zero (tare) value setted with CAL-5, or
returning back to FUN 4 and following the point a) described below. The ESC key exits the function without
changing anything.
At the Power on, this tare is zeroed.

"REPOR.TECH.PERS."
To access to the FUN-4 menu, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-4 and pressing the
(Enter) key.
In this menu there is the possibility of following 2 ways:
a) Press immediately the (enter) key without insert any value, at this point the NET Led is turned on.
If this Tare is already setted, is canceled and the NET Led is turned off.
b) With the (up) key or the (down) key sets the weight to be removed from the visualisation.
By pressing the (enter) key is confirmed the tare gained and the NET Led is turned on.

5.4 FUN-5
To set the parameters for the CALIBRATIONS, from the FUN-0 menu, with the (arrow up) key, search FUN-
5 and press (Enter) key. If you press the (Enter) key on a non-operational parameter, the instrument
returns to CAL-0. Use the (arrow up) and (arrow down) keys to select functions or parameters to
visualize or modify.

Note: Once correctly programmed the instrument, you should write down the parameters for an easy recovery
of the same. In Annex B is placed a table to report the setted parameters.

FUN-5
CAL-0 UNIT OF MEASURE SETTABLE: g, kg, t, lb DEFAULT kg
CAL-1 FILTER FROM 0 TO 6 DEFAULT 0
CAL-2 DECIMAL POINT FROM XXXXXX TO X.XXXXX DEFAULT XXXX.XX
CAL-3 MOLTIPLIER FROM 1 TO 5 DEFAULT 1
CAL-4 FULL SCALE FROM 1 TO 999999 DEFAULT 50.00
CAL-5 TARE INSTRUMENT CALIBRATION
CAL-6 GAIN INSTRUMENT CALIBRATION
CAL-7 CONVERTER VALUE ONLY VISUALISATION
CAL-8 ANALOG OUTPUT ZERO FROM 0 TO 4096 DEFAULT 0
CAL-9 ANALOG OUTPUT MAX FROM 0 TO 4096 DEFAULT 4086
CAL-A SERIAL ADDRESS FROM 0 TO 32 DEFAULT 0
CAL-B PEAK FROM 0 TO 1 DEFAULT 0
CAL-C MANUAL TARE VALUE ONLY VISUALISATION IF SETTED IN FUN-4.
DEFAULT 0
CAL-D NOT OPERATIONAL
CAL-E NOT OPERATIONAL
CAL-F LINEARITY 1 SCALE MEASUR. FROM 0 TO FULL SCALE DEFAULT 0
IF LINEARITY 1 > 0 LINEARITY 2 SCALE MEASUR. FROM LINEARITY 1 TO F.S. DEFAULT 0
IF LINEARITY 2 > 0 LINEARITY 3 SCALE MEASUR. FROM LINEARITY 2 TO F.S. DEFAULT 0
IF LINEARITY 3 > 0 LINEARITY 4 SCALE MEASUR. FROM LINEARITY 3 TO F.S. DEFAULT 0

DESCRIPTION OF THE PARAMETERS FOR THE INSTRUMENT CALIBRATING


Following are explained all the calibration parameters in this instrument that you can access and modify.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 19

"REPOR.TECH.PERS."
To access to the FUN-5 menu, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and pressing the
(Enter) key. In case you want to access in the protected menus (shown in red) with the homologable version of
the instrument, you must follow the correct procedure, otherwise the instrument comes back to FUN-0.

5.4.1 CAL-0
UNIT OF MEASURE
This parameter sets the units of the instrument as a function of the precision required by the system. Are
selectable g, kg, t, lb. Even the communication protocols transmit the value set in this menu.

"REPOR.TECH.PERS."
To access to the UNIT OF MEASURE parameter, simultaneously press the (arrow up) and (arrow down)
keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and
press the (Enter) key, you enter into the CAL-0 parameter, and press the (Enter) key. With the (arrow
up) and (arrow down) keys set the unit of measure and press (Enter) to confirm it, then you comes back to
CAL-0, press ESC key to quit from the menus or press the (arrow up) and (arrow down) keys to select
another calibration parameter. To access (with the homologable version of the instrument) to the UNIT OF
MEASURE parameter, you must enter in the protected menu following the correct procedure, otherwise the
instrument comes back to CAL-0.

If one or more storages has already carried out with the ALIBI MEMORY, FULL appears onto the
display and you are put into the FUN-0 menu, appears the READ visualization, if you want to change
the unit of measure MUST first erase the recordings made. For it with the (arrow up) and (arrow
down) keys search ERASE and press the (enter) key. Return within CAL-0 via the above procedure
and set the unit of measure you want.

5.4.2 CAL-1
FILTER
The FILTER parameter has the purpose to stabilize the values read in input onto the 9-pin connector but the
data output values are provided continuously.

Must be ABSOLUTLY set a minimum filter necessary to obtain the indication of weight stable when the
amount on the balance does not change.

The stabilization is achieved by increasing the number of samples before making available the weight stable,
on the analog output, on serial, on Ethernet and to the display. Spite of the delays due to the acquisition of
samples for the mean, providing continuous readings allows to turn off the LED of the Stable Weight when the
weight (filtered) changes.

The setting values for this parameter are between 1 and 6.

Examples: Response time before release the STABLE WEIGHT value is as per the table below.

NAME NUM. SAMPLE DELAY(s)


FIL-0 8 0,16
FIL-1 16 0,33
FIL-2 32 0,65
FIL-3 64 1,3
FIL-4 128 2,6
FIL-5 256 5,2
FIL-6 512 10,4

© 2012 ELETTRONDATA S.R.L.


20 ED640 Instrument

"REPOR.TECH.PERS."
To access to the FILTER parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the
(Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-1 and press the
(Enter) key. With the (arrow up) and (arrow down) keys sets up the filter value and press the (Enter)
key to confirm it, then you comes back to CAL-0, press ESC key to quit from the menus or press the (arrow
up) and (arrow down) keys to select another calibration parameter.

5.4.3 CAL-2
DECIMAL POINT
This parameter sets the visualization to display as a function of the measuring unit and the precision required
by the system.

"REPOR.TECH.PERS."
To access to the DECIMAL POINT parameter, simultaneously press the (arrow up) and (arrow down)
keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and
press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-2 and
press the (Enter) key. It is displayed ------ with the (arrow up) and (arrow down) keys set the decimal
point and press (Enter) to confirm it, then you comes back to CAL-0, press ESC key to quit from the menus
or press the (arrow up) and (arrow down) keys to select another calibration parameter. To access (with
the homologable version of the instrument) to the DECIMAL POINT parameter, you must enter in the
protected menu following the correct procedure, otherwise the instrument comes back to CAL-0.

In case you have version approvable of the instrument, ie at power ON does not appear ED640.1 or
ED640.E, and one or more memorizations were already carried out with the ALIBI MEMORY, the word
FULL appears onto the display and then come back into the FUN-0 menu, appears the READ
visualization, if you want to change the decimal point MUST first erase the recordings made. For it with
the (arrow up) and (arrow down) keys search ERASE and press the (enter) key. Return within
CAL-2 via the above procedure and set the decimal point you want.

5.4.4 CAL-3
MULTIPLIER
This parameter defines the number of divisions of increase and decrease of the value in visualization as the
list:

COS=1 increase/decrease of 1 division in 1 division


COS=2 increase/decrease of 2 divisions in 2 divisions
COS=3 increase/decrease of 10 divisions in 10 divisions
COS=4 increase/decrease of 20 divisions in 20 divisions
COS=5 increase/decrease of 5 divisions in 5 divisions

Example: When working with metric instrument that has 3000 divisions, if the scale is of 5000 divisions, must
use at least multiplier 2, so the displayed value will increase or decrease of two digit at a time.

"REPOR.TECH.PERS."
To access to the MULTIPLIER parameter, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the
(Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-3 and press the
(Enter) key. With the (arrow up) and (arrow down) keys set the multiplier and press (Enter) key to
confirm it, then you comes back to CAL-0, press ESC key to quit from the menus or press the (arrow up)
and (arrow down) keys to select another calibration parameter. To access (with the homologable version of
the instrument) to the MULTIPLIER parameter, you must enter in the protected menu following the correct
procedure, otherwise the instrument comes back to CAL-0.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 21

5.4.5 CAL-4
FULL SCALE
Sets the maximum value the instrument can display, beyond that the display visualize as described in Display
Visualizations. Usually this value coincides with the maximum value read in input, which depends on the unit
of measurement and on the precision required by the system. The analog output provides a 0-10 Vdc signal
variable between the TARA value, which is the indication of zero (0 Vdc), and the full scale value (+10 Vdc).

"REPOR.TECH.PERS."
To access to the FULL SCALE parameter, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the
(Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-4 and press the
(Enter) key. With the (arrow up) and (arrow down) keys set the full scale and press (Enter) key to
confirm it, then you comes back to CAL-0, press ESC key to quit from the menus or press the (arrow up)
and (arrow down) keys to select another calibration parameter. If there are not errors, it goes back to CAL-0
, otherwise refer to MESSAGES. To access (with the homologable version of the instrument) to the FULL
SCALE parameter, you must enter in the protected menu following the correct procedure, otherwise the
instrument comes back to CAL-0.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

5.4.6 CAL-5
TARE
This parameter, where you define the reference value of EMPTY or 0 value (zero), together with the CAL-6
parameter where you define the reference value of FULL or F.S. value, represents the actual calibration of the
instrument. Both are performed as in CALIBRATION.
You should perform the calibration sequence after 15-20 minutes that the instrument is turned on, so
as to enable electronic components to reach thermal equilibrium.
Keep in mind this observation, even when, at calibration occurred, you should notice a slight difference
between the turned off and on of the instrument.

"REPOR.TECH.PERS."
To access to the TARE parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the (Enter)
key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-5 and press the (Enter)
key. Compare the ZERO message, press (Enter) key to confirm it, then appear the DONE message. If there
are not errors, it goes back to CAL-0, otherwise refer to MESSAGES. Press ESC key to quit from the menus
or press the (arrow up) and (arrow down) keys to select another calibration parameter. To access (with
the homologable version of the instrument) to the TARE parameter, you must enter in the protected menu
following the correct procedure, otherwise the instrument comes back to CAL-0.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

5.4.7 CAL-6
GAIN
This parameter, where you define the reference value of FULL or F.S. value, together with the CAL-5
parameter where you define the reference value of EMPTY or 0 (zero) value, represents the actual calibration
of the instrument. Both are performed as in CALIBRATION.
You should perform the calibration sequence after 15-20 minutes that the instrument is turned on, so
as to enable electronic components to reach thermal equilibrium.
Keep in mind this observation, even when, at calibration occurred, you should notice a slight difference
between the turned off and on of the instrument.

© 2012 ELETTRONDATA S.R.L.


22 ED640 Instrument

"REPOR.TECH.PERS."
To access to the GAIN parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the (Enter)
key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-6 and press the (Enter)
key. With the (arrow up) and (arrow down) keys set the sample quantity put on the system to be
evaluated and press (Enter) key to confirm it. If there are not errors, it goes back to CAL-0, otherwise refer
to MESSAGES. Press ESC key to quit from the menus or press the (arrow up) and (arrow down) keys to
select another calibration parameter. To access (with the homologable version of the instrument) to the GAIN
parameter, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to CAL-0.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

5.4.8 CAL-7
VALUE CONVERTER
The CONVERTER VALUE parameter is only visualization and is designed to verify the statement of the read
onto the 9-pin input connector. This indication remains until you press ESC, so remains also turned on the F
Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the CONVERTER VALUE parameter, press simultaneously the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5
and press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-7
and press the (Enter) key. Press ESC key to comes back to CAL-0, press ESC key again to quit from the
menus or press the (arrow up) and (arrow down) keys to select another calibration parameter.

5.4.9 CAL-8
SETS ANALOGICAL ZERO
This parameter is used to set the value of the analog refers to the value of ZERO (Tare) of the instrument.
Default is set to zero (0 Vdc), but you can raise it up to 4095 divisions (+10 Vdc). Example: Whatever it is the
Full Scale set, if this parameter is 0 (zero) and the CAL-9 kept in 4095, the 0-10 V analog output will be
divided by 4095 divisions. Therefore, every step of increase or decrease of this two parameters, will be worth
about 2.45 mV. In the event that the equipment, in cascade of a this instrument, needs an analog input from 1
V to 9 V, you must need to set CAL-8=409 and CAL-9=3674.

"REPOR.TECH.PERS."
To access to the ANALOGICAL ZERO parameter, simultaneously press the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5
and press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-8
and press the (Enter) key. It is displayed 000000 with the (arrow up) and (arrow down) keys set the
analogical zero and press (Enter) key to confirm it, then you comes back to CAL-0, press ESC key to quit
from the menus or press the (arrow up) and (arrow down) keys to select another calibration parameter.
To access (with the homologable version of the instrument) to the ANALOGICAL ZERO parameter, you must
enter in the protected menu following the correct procedure, otherwise the instrument comes back to CAL-0.

5.4.10 CAL-9
SETS ANALOGICAL FULL SCALE
This parameter is used to set the value of the analog refers to the value of maximum (Full Scale) of the
instrument. Default is set to 4095, but you can decrease it to zero (0 Vdc).
Example: Whatever it is the full scale set, if this parameter is 4095 and the CAL-8 kept in 0 (zero), the 0-10 V
analog output will be divided by 4095 divisions. Therefore, every step of increase or decrease, this two
parameters, will be worth about 2.45 mV. In the event that the equipment, in cascade of a this instrument,
needs an analog input from 1 V to 9 V, you must need to set CAL-8=409 and CAL-9=3674.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 23

"REPOR.TECH.PERS."
To access to the ANALOGICAL FULL SCALE parameter, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search
FUN-5 and press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search
CAL-9 and press the (Enter) key. It is displayed 004095 with the (arrow up) and (arrow down) keys set
the analogical full scale and press (Enter) key to confirm it. Then, you comes back to CAL-0, press ESC key
to quit from the menus or press the (arrow up) and (arrow down) keys to select another calibration
parameter. To access (with the homologable version of the instrument) to the ANALOGICAL FULL SCALE
parameter, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to CAL-0.

5.4.11 CAL-A
SERIAL ADDRESS
To operate with the serial line at the instrument should be assigned a serial identification number or unique
serial address. For a single instrument, connected to the serial line will be given the number 01, if the
instruments are more than one, the number will be assigned progressively starting from that number. For links,
see CONNECTIONS.
It is not possible to coexist instruments with same number on the same serial line.

"REPOR.TECH.PERS."
To access to the SERIAL ADDRESS parameter, press simultaneously the (arrow up) and (arrow down)
keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and
press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-A and
press the (Enter) key. With the (arrow up) and (arrow down) keys set the serial address and press
(Enter) key to confirm it, then you comes back to CAL-0, press ESC key to quit from the menus or press the
(arrow up) and (arrow down) keys to select another calibration parameter. The serial port parameters are
programmable, entering the SER menus as by procedure, in FUN-E menu.

5.4.12 CAL-B
PEAK
The peak parameter displays the largest value reached up to that point, from the measured quantity in input
onto the 9-pin connector of the instrument. Entering this parameter is activated the threshold of maximum .
At any moment you can reset the peak reached by acting on the ESC key, the indication is brought to the
value currently present at the input. With the function peak actived is available ONLY the minimum threshold
, which is closely related to the indication provided by the instrument. If the value exceeds the threshold
value of the minimum set, the Led turns off and the relay contact opens, if at the contrary the view would
lead to a value below the threshold value set (eg. due to a cancellation with ESC key), the Led goes on
and the contact closes. If you reset an input signal with a peak below the tare value, display remains 000000,
so are no longer displayed negatives values. If during the operation should be less the Power Supply, the
instrument at restore displays the value currently present at the input. Please note that the analog output is
closely linked to the indication (and thus at the peak) and not the value actually present in input onto the 9-pin
connector. Until remains active the function of peak remains also turned on the F Led for indication that is a
FUNCTION, so not a measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the PEAK parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5 and press the (Enter)
key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-B and press the (Enter)
key. The activation of the peak is obtained by setting PIC-01 and the disactivation by setting PIC-00. With the
(arrow up) and (arrow down) keys enable or disable the peak and press (Enter) key to confirm it, then
you comes back to CAL-0, press ESC key to quit from the menus or press the (arrow up) and (arrow
down) keys to select another calibration parameter.

© 2012 ELETTRONDATA S.R.L.


24 ED640 Instrument

5.4.13 CAL-C
MANUAL TARE VALUE
The MANUAL TARE VALUE parameter is only visualization and is designed to verify the indication of Tara
entered by pressing the TARA key (down arrow) for three seconds or by FUN-4. If it is not set any manual
tare, the instrument visualize 0 (zero). The indication varies depending on the setting of the decimal point. This
indication remains until you press ESC key, so remains also turned on the F Led for indication that is a
FUNCTION, so not a measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the MANUAL TARE VALUE parameter, press simultaneously the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5
and press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-C
and press the (Enter) key. Press ESC key to back to CAL-0, press ESC key again to quit from the menus or
press the (arrow up) and (arrow down) keys to select another calibration parameter.

5.4.14 CAL-F
LINEARIZATION POINTS
You can insert 4 LINEARIZATION POINTS within the calibration curve of the instrument, if the input signal
does not correspond to the value given by the system to be evaluated. If the first value is set to 0 keeps the
original curve. By entering this parameter is turned on the threshold of maximum . If a linearization is
already existent, it will visualized in the menu READ. Linearization is obtained by changing the points of the
curve calculated between tare and full scale. You must charge physically, a sample quantity and correct the
display by entering the correct value by selecting one of the coefficients of linearization:
The only constraint imposed by the instrument is that the sequence of values must be uniform:
The value for LIN1 must be between that of Tare and to LIN2
The value for LIN2 must be between that of LIN1 and that of LIN3
The value for LIN3 must be between that of LIN2 and that of LIN4
The value for LIN4 must be between that of LIN3 and the one used for Full Scale.
Remain unchanged values tare and full scale. If a coefficient of linearization is set to 0 is disabled and can not
add more values later. To perform a proper linearization is necessary to know the points of the curve to
change and possibly the analog input to which they are associated.

"REPOR.TECH.PERS."
To access to the LINEARIZATION POINTS parameter, simultaneously press the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-5
and press the (Enter) key, you enter into the CAL-0 parameter, with the (arrow up) key, search CAL-F
and press the (Enter) key. The instrument displays SET, with the (arrow up) and (arrow down) keys
select: the programming SET or read the data setted READ and press (Enter) key to confirm.
Entering in the menu SET is displayed the first available, point of linearization, having available, the sample
quantity or a quantity equivalent to that to vary, put it on the system that is being evaluated, and will make the
change by assigning the new value. If previously have been inserted points, the instrument allows to choose to
modify them or there is also the function CLEAR to erase any data setted. If the points are more than one to
change it is the same as described above.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 25

Entering in the menu READ are proposed 4 linearisation point with the ability to view the data that was
displayed before the change of the point (IN) and that corresponding changed in the output parameter (OUT).
With the (arrow up) and (arrow down) keys select the point to be checked and press (Enter) key to see
the value. Press the (Enter) key to return to SET and press the ESC key to return to CAL-0, press the ESC
key again to exit the menu or press the (arrow up) and (arrow down) keys to select another parameter
calibration. To access (with the homologable version of the instrument) to the LINEARIZATION POINTS
parameters, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to CAL-0.

5.5 FUN-6
To set the parameters for the ANALOGICAL OUTPUT ALIGNMENT, from the FUN-0 menu with the (arrow
up) key search FUN-6 and press (Enter).

FUN-6
ALIN There is the possibility of introducing a fictitious quantity to alignment with other systems.
nnnn Enter the quantity, by the keyboard, to be simulated on the analogical output.

In this menu there is the possibility of aligning the analogical output of this instrument with one in cascade,
using the value displayed without having to enter some sample quantity on the system to be evaluated. To do
this must follow the steps described below.
Remember that the instrument must necessarily be first set up and calibrated for the system to be evaluated.
By entering this parameter is turned on the threshold of maximum . This indication remains until you press
ESC, so remains also turned on the F Led for indication that is a FUNCTION, so not a measured quantity but a
generic numeric value.

"REPOR.TECH.PERS."
To access to the ANALOGICAL OUTPUT ALIGNMENT parameter, simultaneously press the (arrow up)
and (arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-6 and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
displays ALIN, after two seconds will be displayed 000000, the indication varies depending on the setting of
the decimal point. With the (arrow up) and (arrow down) keys set a notional quantity, also equal to full
scale, and press (Enter) key to confirm it. A claim as modified will remain until you press the button (Enter)
key. At the same time also the analog output will be varied accordingly to the data displayed. When setting up
the fictitious amount, if no buttons are pressed for 5 seconds will revert to the previous value but remains
within the menu, press the key (Enter) it returns to the quantity fictitious. Back in view, by pressing the ESC
key or if there is a increase of the value in input, onto the 9-pin connector, at least of 100 divisions. To access
(with the homologable version of the instrument) to the ANALOGICAL OUTPUT ALIGNMENT parameters,
you must enter in the protected menu following the correct procedure, otherwise the instrument comes back
to FUN-0.

5.6 FUN-8
To set the parameters for the ADJUSTING THE VALUE OF GAIN, from the FUN-0 menu with the (arrow
up) key search FUN-8 and press (Enter).

FUN-8
SPAN There is the possibility of introducing a fictitious quantity to adjust the value of gain.
nnnn Enter the quantity, by the keyboard, of F.S. to be simulated on the display and on the analog output.

In this menu there is the possibility to adjust the quantity inserted in the function of gain of this instrument,
using a value set by the keyboard of a quantity simulating the signal read in input, onto the 9-pin connector,
without having to enter the sample quantity on the system to evaluate. This allows to adjust the gain in
instrument where you cannot reweigh the material (large quantity) and are not available the sample quantity.

© 2012 ELETTRONDATA S.R.L.


26 ED640 Instrument

To do this must follow the steps described below. Remember that the instrument must necessarily be first set
up and calibrated for the system to be evaluated. Remains also turned on the F Led for indication that is a
FUNCTION, so not a measured quantity but a generic numeric value

"REPOR.TECH.PERS."
To access to the ADJUSTING THE VALUE OF GAIN parameters, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-8 and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
displays SPAN, after two seconds will be displayed the full scale of the instrument. With the (arrow up) and
(arrow down) keys set a notional quantity and press the (Enter) key to confirm it and returns to the FUN-0
menu. This number replaces the current value of full scale, at parity value read in input, onto the 9-pin
connector. At the same time also the analogical output will be changed accordingly to the data displayed. To
access (with the homologable version of the instrument) to the ADJUSTING THE VALUE OF GAIN
parameters, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to FUN-0.

5.7 FUN-9
To set the parameters for the eCALIBRATIONS, from the FUN-0 menu, with the (arrow up) key, search
FUN-9 and press (Enter) key. If you press the press (Enter) key on a non-operational parameter, the
instrument returns to eCAL-0. Use the (arrow up) and (arrow down) keys to select functions or
parameters to visualize or modify.

Note: Once correctly programmed the instrument, you should write down the parameters for an easy recovery
of the same. In Annex B is placed a table to report the setted parameters.

FUN-9
eCAL-0 NOT OPERATIONAL
eCAL-1 DISABLE AUTO 0 DEVICE DEFAULT = 0; Enabled features.
eCAL-2 TARE LOCK DEFAULT = 0; Enabled features.
eCAL-3 NOT OPERATIONAL
eCAL-4 NOT OPERATIONAL
eCAL-5 ENHANCED CALIBRATION OF GAIN
eCAL-6 ENHANCED CALIBRATION OF TARE
From eCAL-7 to eCAL-F are NOT OPERATIONAL enhanced parameters.

DESCRIPTION OF PARAMETERS FOR THE ENHANCED INSTRUMENT CALIBRATING


Following are explained all the enhanced calibration parameters that you can access and modify.

"REPOR.TECH.PERS."
To access to the ENHANCED CALIBRATION menu, simultaneously press the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-9
and pressing the (Enter) key. In case you want to access in the protected menus (shown in red) with the
homologable version of the instrument, you must follow the correct procedure, otherwise the instrument
comes back to FUN-9.

5.7.1 eCal-1
Functions: ZERO-TRACKING and SUPPERSION OF NEGATIVE are automatic, but can be disabled via this
menu.

DA0D
The parameter DISABLE AUTO 0 DEVICE allows you to exclude or include the features of automatic zeroing
of the display for both positive and negative quantities.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 27

"REPOR.TECH.PERS."
To access to the DISABLE AUTO 0 DEVICE parameter, simultaneously press the (arrow up) and (arrow
down) keys and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-9
and press the (Enter) key, you enter into the eCAL-0 parameter, with the (arrow up) key, search eCAL-1
and press the (Enter) key. By default the functions are activated and the parameter is set DA0D-0. Disabling
functionality by set DA0D-1 and press the (Enter) key to confirm it, then you comes back to eCAL-0, press
ESC key to quit from the menus or press the (arrow up) and (arrow down) keys to select another
enhanced calibration parameter. To access (with the homologable version of the instrument) to the DISABLE
AUTO 0 DEVICE parameter, you must enter in the protected menu following the correct procedure,
otherwise the instrument comes back to FUN-9.

5.7.2 eCal-2
The auto-eliminate functions of TARA DEVICE, only manual (by pressing the TARE key or by FUN-4 menu),
can be disabled through this enhanced parameter.

tLOC
The parameter TARA LOCK allows you to exclude or include the features of the manual tare, to auto-eliminate
itself when the quantity falls below the 90% of the tare value setted.

"REPOR.TECH.PERS."
To access to the TARA LOCK parameter, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-9 and press the
(Enter) key, you enter into the eCAL-0 parameter, with the (arrow up) key, search eCAL-2 and press the
(Enter) key. By default the functions are activated and the parameter is set tLOC-0. Disabling functionality by
set tLOC-1 and press the (Enter) key to confirm it, then you comes back to eCAL-0, press ESC key to quit
from the menus or press the (arrow up) and (arrow down) keys to select another enhanced calibration
parameter. To access (with the homologable version of the instrument) to the TARA LOCK parameter, you
must enter in the protected menu following the correct procedure, otherwise the instrument comes back to
FUN-9.

5.7.3 eCal-5
GAIN
This parameter, where you define the reference value of FULL or F.S. value, together with the eCAL-6
parameter where you define the reference value of EMPTY or 0 (zero) value, represents the enhanced
calibration of the instrument. Both are performed as in eCALIBRATION.
You should perform the calibration sequence after 15-20 minutes that the instrument is turned on, so
as to enable electronic components to reach thermal equilibrium.
Keep in mind this observation, even when, at calibration occurred, you should notice a slight difference
between the turned off and on of the instrument.

"REPOR.TECH.PERS."
To access to the GAIN parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-9 and press the (Enter)
key, you enter into the eCAL-0 parameter, with the (arrow up) key, search eCAL-5 and press the (Enter)
key. With the (arrow up) and (arrow down) keys set the sample quantity put on the system to be
evaluated and press (Enter) key to confirm it. If there are not errors, it goes back to eCAL-0, otherwise refer
to MESSAGES. Press ESC key to quit from the menus or press the (arrow up) and (arrow down) keys to
select another enhanced calibration parameter. To access (with the homologable version of the instrument) to
the GAIN parameter, you must enter in the protected menu following the correct procedure, otherwise the
instrument comes back to FUN-9.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

© 2012 ELETTRONDATA S.R.L.


28 ED640 Instrument

5.7.4 eCal-6
TARE
This parameter, where you define the reference value of EMPTY or 0 (zero) value, together with the eCAL-5
parameter where you define the reference value of FULL or F.S. value, represents the enhanced calibration of
the instrument. Both are performed as in eCALIBRATION.
You should perform the calibration sequence after 15-20 minutes that the instrument is turned on, so
as to enable electronic components to reach thermal equilibrium.
Keep in mind this observation, even when, at calibration occurred, you should notice a slight difference
between the turned off and on of the instrument.

"REPOR.TECH.PERS."
To access to the TARE parameter, simultaneously press the (arrow up) and (arrow down) keys and the
(enter) key, you enter into the FUN-0 menu, with the (arrow up) key, search FUN-9 and press the (Enter)
key, you enter into the eCAL-0 parameter, with the (arrow up) key, search eCAL-6 and press the (Enter)
key. Compare the ZERO message, press (Enter) key to confirm it, then appear the DONE message. If there
are not errors, it goes back to eCAL-0, otherwise refer to MESSAGES. Press ESC key to quit from the menus
or press the (arrow up) and (arrow down) keys to select another enhanced calibration parameter. To
access (with the homologable version of the instrument) to the TARE parameter, you must enter in the
protected menu following the correct procedure, otherwise the instrument comes back to FUN-9.

Note: Do not try to change this parameter when the calibration is already occurred, because it causes
an automatic change of the excursion of the signal, if that happens you should rerun the calibration
procedure.

5.7.5 eCalibration

"REPOR.TECH.PERS."
PROCEDURES TO PERFORMING THE INSTRUMENT CALIBRATION
Should be perform the calibration sequence after 15-20 minutes that the instrument is turned on, so as
to enable electronic components to reach thermal equilibrium.

GAIN
Permit to calibrate the instrument with a sample quantity. To have a good accuracy of the calibration is
recommended to use a sample quantity equivalent to the next full scale set. Calibrations performed with
samples of less than 50% of full scale produce a degradation of accuracy. At the start-up that function should
be performed only after using the TARE function. In a second step can be performed individually to perform
subsequent adjustments of the indication, if they should be required (change of inclination of the straight line
calibration).

Proceed as follows:
- access the eCAL-5 function and press (Enter).
- appears 000000.
- put the sample quantity on the system to be evaluated.
- press (Enter), it moves the selection on the display to the right, to select the digit to modify and with the
(up arrow) and (arrow down) keys set the correct value and press (Enter) till the end of the digits, press
(Enter) again to confirm the value setted. The ESC key moves the selection on the digit to the left, if it arrived
at the digit units, subsequent press ESC exits from the setup without saving the data.
- If there are not errors, it comes back to eCAL-0, now you should go to eCAL-6 function to terminate the
eCalibration, otherwise refer to MESSAGES and repeat the procedure.

TARE
Ensure that the system to be evaluated is empty and in the instrument were set Full Scale and decimal point
parameters.

Proceed as follows:
- access the eCAL-6 function and press (Enter).
- appears the eZERO message, press (Enter) key to confirm the empty condition or of 0 (zero) on the
measure scale.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 29

- If there are not errors, appears the DONE message and it goes back to eCAL-0, press ESC key several
times to quit from the menus. Otherwise refer to MESSAGES and repeat the procedure.

At calibration occurred is possible to stabilize the indication by acting on the FILTER function.
Note: In the condition in which you want to tweak the tare for the presence, for example, of fixed residues of
material in the system to evaluate, you can rerun the function of TARE mind that this merely refers to the
entire range of calibration function of the new value (the straight line calibration slide up or down without
changing slope). Where changes are made to the system which cause significant changes on the input signal
(eg, replacement of the load cells) is necessary to rerun the entire calibration sequence (GAIN + TARE).

5.8 FUN-A
To set the parameters for the PARAMETRIC CALIBRATION OF LOAD CELLS, from the FUN-0 menu with the
(arrow down) key search FUN-A and press (Enter). If the instrument is not set with input load cell
(ED340/1) will be displayed ERR-7.

FUN-A
n.nn There is the possibility to insert the sensitivity of load cells with two decimal in mV/V.
nn Insert the number of load cells mounted in the system to evaluate.

In this menu there is the possibility to program the instrument without using sample quantities, passing the
same information that allow the instrument to recreate the curve of input. Of course it is necessary for load
cells to be precise, all identical and from the same supplier. The instrument requires up to two decimal places
for the sensitivity. By entering this parameter is turned on the threshold of maximum . Remains also turned
on the F Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value

"REPOR.TECH.PERS."
To access to the PARAMETRIC CALIBRATION OF LOAD CELLS parameters, simultaneously press the
(arrow up) and (arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-A
and press (Enter) key. The instrument displays 0.00, with the (arrow up) and (arrow down) keys set the
sensitivity up to two decimal places of the cells in mV/V and press (Enter) key to confirm it. Instrument
displays 00, with the (up arrow) and (down arrow) keys set the number of load cells mounted in the
system to be evaluated and press the (Enter) key to confirm it and returns to the FUN-0 menu. To access
(with the homologable version of the instrument) to the PARAMETRIC CALIBRATION OF LOAD CELLS
parameters, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to FUN-0.

5.9 FUN-B
To set the parameters for the PRECALIBRATION OF LOAD CELLS, from the FUN-0 menu with the (arrow
up) key search FUN-B and press (Enter).

FUN-B
ZERO There is the possibility to program a pre-calibration of the zero of the IN-D input.
IN-D There is the possibility to program a pre-calibration of the full scale of the IN-D input.
ZERO There is the possibility to program a pre-calibration of the zero of the IN-E input.
IN-E There is the possibility to program a pre-calibration of the full scale of the IN-E input.

In this menu there is the possibility to program the instrument using the simulator for load cells, enabling him to
recreate the curve of input. To do this must follow the steps described below. Remains also turned on the F
Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value.
Should be perform the calibration sequence after 15-20 minutes that the instrument is turned on, so as
to enable electronic components to reach thermal equilibrium.

© 2012 ELETTRONDATA S.R.L.


30 ED640 Instrument

"REPOR.TECH.PERS."
To access to the PRECALIBRATION OF LOAD CELLS parameters, simultaneously press the (arrow up)
and (arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-B and press
(Enter) key. The instrument requires a password 00000, set 12345 and press the (Enter) key. The
instrument visualize ZERO, on the simulator, check that the position is 0 and press the (Enter) key. The
instrument after an analysis of the input data, shows the value of the converter, if it is correct press the
(Enter) key. The instrument visualize IN-D, on the simulator, check that the position is 1 and press the
(Enter) key. The instrument after an analysis of the input data, shows the value of the converter, if it is correct
press the (Enter) key. The instrument visualize ZERO, on the simulator, check that the position is 2 and
press the (Enter) key. The instrument after an analysis of the input data, shows the value of the converter, if
it is correct press the (Enter) key. The instrument visualize IN-E, on the simulator, check that the position is 3
and press the (Enter) key. The instrument after an analysis of the input data, shows the value of the
converter, if it is correct press the (Enter) key. If no errors occur, the instrument displays DONE and return in
view mode. To access (with the homologable version of the instrument) to the PRECALIBRATION OF LOAD
CELLS parameters, you must enter in the protected menu following the correct procedure, otherwise the
instrument comes back to FUN-0.

5.10 FUN-D
To visualize the SERIAL NUMBER of the instrument, from the FUN-0 menu with the (arrow down) key
search FUN-D and press (Enter).

FUN-D
nnnnnn There is the possibility of visualize the serial number of the instrument.

In this menu there is the possibility to view the serial number of the instrument, necessary to obtain any
Customer Support. Remains also turned on the F Led for indication that is a FUNCTION, so not a measured
quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the SERIAL NUMBER parameter, simultaneously press the (arrow up) and (arrow down)
keys and the (enter) key, enter in FUN-0 with the (arrow up) key seek FUN-D and press the (Enter) key.

5.11 FUN-E
To set the parameters for the OPERATING, from the FUN-0 menu, with the (arrow up) key, search FUN-E
and press (Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key.
Note: Once correctly programmed the instrument, you should write down the parameters for an easy recovery
of the same. In Annex B is placed a table to report the parameters.

FUN-E
IN SELECTION OF THE INPUT TYPE. FROM 0 TO F DEFAULT E
DEF SET DEFAULT DATA. FROM 0 TO 2 DEFAULT 0
TST EXECUTE THE TEST OF LEDS, DISPLAY AND DIGITAL INPUT.
OUT SELECTION THE TYPE OF ANALOGICAL FROM 0 TO 1 DEFAULT 0
OUTPUT
SER SET THE SERIAL LINE DATA. SEE SER DEFAULT 9600, N, 8, 1,
TRA=2, PRT=0
ETHERN SET THE ETHERNET LINK DATA. SEE ETHERN DEFAULT ETH-0 DISABLED
RTC SET THE CLOCK DATA TO MEMORIZE THE WEIGHED SEE RTC
NOISE VISUALIZE THE VALUE OF NOISE OF THE ANALOG INPUT. SEE NOISE
GRAVIT VISUALIZE THE VALUE OF GRAVITY SETS FOR DEFAULT. SEE GRAVIT

© 2012 ELETTRONDATA S.R.L.


Basic Functions 31

DESCRIPTION OF OPERATING PARAMETERS OF THE INSTRUMENT.


Following are explained all the parameters of this instrument that you can access and modify.

"REPOR.TECH.PERS."
To access to the OPERATING parameters, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, enter in FUN-0 with the (arrow up) key seek FUN-E and press the (Enter) key. In
case you want to access in the protected menus (shown in red) with the homologable version of the
instrument, you must follow the correct procedure, otherwise the instrument comes back to FUN-E.

5.11.1 IN
To set the parameters for the INPUT TYPE of the instrument, from IN menu, press the (Enter) key.

IN
IN-x There is the possibility of select the input type of the instrument.

In this menu there is the possibility to select the INPUT TYPE, necessary for the proper functioning of the
instrument. By entering this parameter is turned on the threshold of maximum . Remains also turned on the
F Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the INPUT TYPE parameter, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press (Enter) key. The
instrument requires a password PAS-0, set E and press (Enter) key. The instrument visualize IN, press the
(Enter) key. The instrument visualize IN-x, where x is the letter or number associated to the analog input type
of the instrument, to use. For selecting the input type, used for the system to be evaluated make refer to
OPERATING MODES. To access (with the homologable version of the instrument) to the INPUT TYPE
parameter, you must enter in the protected menu following the correct procedure, otherwise the instrument
comes back to FUN-E.

5.11.2 DEF
To set the DEFAULT VALUES of the instrument, from the IN menu, with the (arrow up) key search DEF and
press the (Enter) key.

DEF
DEF-x There is the possibility of set the default value of the instrument.

In this menu there is the possibility to set the DEFAULT VALUES, necessary for the proper functioning of the
instrument. By entering this parameter is turned on the threshold of maximum . Remains also turned on the
F Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the DEFAULT VALUE parameter of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek DEF, then press the (Enter) key. With the
(arrow up) and (arrow down) keys set DEF-1 to restore the parameters for the instrument ED640/2
(potentiometer input). Or with the (arrow up) and (arrow down) keys set DEF-2 to restore the parameters
for the instrument ED640/1 (load cells input). Any type of parameters will be restored once pressed the
(Enter) key to confirm, the instrument performs an automatic restart. Remember to reinsert all the data and
rerun the calibration procdure as before being fully operational, the instrument ED640 must be adapted to the
characteristics of the system to be evaluated. To access (with the homologable version of the instrument) to
the DEFAULT VALUE parameter, you must enter in the protected menu following the correct procedure,
otherwise the instrument comes back to FUN-E.
The selling company is not liable for any damage to property or persons or animals caused by
carelessness or rough handling or handling of the instrument.

© 2012 ELETTRONDATA S.R.L.


32 ED640 Instrument

5.11.3 TST
To execute the HARDWARE TEST of the instrument, from the IN menu, with the (arrow up) key search TST
and press the (Enter) key.

TST
TST There is the possibility of check the hardware of the instrument.

In this menu there is the possibility to HARDWARE TEST, necessary for the proper functioning of the
instrument. Pressing the (Enter) key, is performed the check of the Leds and the display, then the instrument
visualize INPUTS. With a 24VDC power supply, connect the GND to the terminal 2 of the instrument and with
the +24VDC wire, touch first the terminal 7 of the instrument, should turn on the threshold of minimum and
then touch the terminal 8 of the instrument, should turn on the threshold of maximum . Return to IN menu,
with the press of any key. These test do not change any settings, at exit from the test, the instrument works as
before.

"REPOR.TECH.PERS."
To access to the HARDWARE TEST of the instrument, simultaneously press the (arrow up) and (arrow
down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press (Enter) key.
The instrument requires a password PAS-0, set E and press (Enter) key. The instrument visualize IN, with
the (arrow up) and (arrow down) keys seek TST, then press the (Enter) key.

5.11.4 OUT
To set the ANALOGICAL OUTPUT TYPE of the instrument, from IN menu, with the (arrow up) key search
OUT and press the (Enter) key.

OUT
OUT-x There is the possibility of set the analogical output type of the instrument.

In this menu there is the possibility to set the ANALOGICAL OUTPUT TYPE, necessary for the instrument to
be adapted to the characteristics of the system to be evaluated. By entering this parameter is turned on the
threshold of maximum . Remains also turned on the F Led for indication that is a FUNCTION, so not a
measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the ANALOGICAL OUTPUT TYPE parameter of the instrument, simultaneously press the
(arrow up) and (arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E
and press (Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The
instrument visualize IN, with the (arrow up) and (arrow down) keys seek OUT, then press the (Enter)
key. To change the analogical output type parameters of the instrument, with the (arrow up) and (arrow
down) keys set the option OUT-0 to select the output 0-10V or 0-20mA or option OUT-1 to select the output 2-
10V or 4-20mA. Any type of parameter will be selected after pressing (Enter) key to confirm, the instrument
will adjust the analog output accordingly. To obtain the two current outputs refer to annex A.

5.11.5 SER
To set the SERIAL LINE parameters of the instrument, from IN menu, with the (arrow down) key search
SER and press the (Enter) key.

SER
SER There is the possibility of set the serial line parameters of the instrument.

In this menu there is the possibility to set the SERIAL LINE parameters, necessary for the instrument to be
adapted to the characteristics of the system to be evaluated. By entering this parameter is turned on the
threshold of maximum . Remains also turned on the F Led for indication that is a FUNCTION, so not a
measured quantity but a generic numeric value.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 33

"REPOR.TECH.PERS."
To access to the SERIAL LINE parameter of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek SER, then pressing the (Enter) key,
following parameters are displayed:

SER SERIAL SPEED FROM 1200 TO 19200 DEFAULT 9600


SERIAL BIT FROM 7 TO 8 DEFAULT 7
SERIAL PARITY EVEN, ODD, NONE DEFAULT E
SERIAL BIT STOP FROM 1 TO 2 DEFAULT 2
TRA SERIAL FROM 0 TO 2 DEFAULT 2
TRANSMISSION
PRT SERIAL PROTOCOL FROM 0 TO 1 DEFAULT 0
IF PROTOCOL > 0 SERIAL PROTOCOL FROM 0 TO 255 DEFAULT 01 (SOH)
START
SERIAL PROTOCOL STOP FROM 0 TO 255 DEFAULT 04 (EOT)

Returns in view mode with the ESC key or if no buttons are pressed for 5 seconds. The following describes the
parameters TRA and PRT.

Serial transmission (TRA) can be disabled by setting with the (arrow up) and (arrow down) keys TRA=0,
or unidirectional setting, with the (arrow up) and (arrow down) keys, TRA=1, in this case the instrument
continuously transmits the data displayed with a set time from 0.1 to 9.9 seconds, or setting, with the (arrow
up) and (arrow down) keys, TRA=2, it is enables the bidirectional transmission, means the instrument
transmits the data displayed on quiries.

The serial protocol (PRT) can be changed by setting, with the (arrow up) and (arrow down) keys, PRT=0,
ELETTRONDATA protocol, the same used for our instruments, or setting, with the (arrow up) and (arrow
down) keys, PRT=1 standard protocol with the selection of a Start Character (0 to 255, equivalent to a char in
ASCII) that replaces the character "*", then a Stop Character (0 to 255) which replaces the "CR". The
transmission will be as follows <start> <sender address> <instrument address> <command> <data> <stop>.

There are two possibilities for serial interface: RS232 and RS485, to specify in the order. To obtain the optional
RS485 serial interface refer to annex A.

5.11.6 ETHERN
To set the ETHERNET LINK parameters of the instrument, from IN menu, with the (arrow down) key search
ETHERN and press the (Enter) key.

ETHERN
ETH-x There is the possibility of set the Ethernet link parameters of the instrument.

In this menu there is the possibility to set the ETHERNET LINK parameters, necessary for the instrument to be
adapted to the characteristics of the system to be evaluated. By entering this parameter is turned on the
threshold of maximum . Remains also turned on the F Led for indication that is a FUNCTION, so not a
measured quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the ETHERNET LINK parameter of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek ETHERN, then pressing the (Enter) key,
the ETH-x parameters is displayed, it permit by the (arrow up) and (arrow down) keys, to enable with 1 or
disable with 0 the Ethernet link.

© 2012 ELETTRONDATA S.R.L.


34 ED640 Instrument

Press (Enter) key to confirm it. If you enable the link, you see the parameters as shown in the table below,
for each press of the (Enter) key confirms the previous data and enter the next. With the final confirmation do
exits the ETHERN menu and returns to the IN menu.

IF ETH-1 IP IP ADDRESS ASSIGNED TO THE INSTRUMENT.


FIRST THREE DIGITS OF THE IP ADDRESS DEF 000
SECOND THREE DIGITS OF THE IP ADDRESS DEF 000
LAST THREE DIGITS OF THE IP ADDRESS DEF 000
MASH NETMASK TO WHICH IS LINKED THE INSTRUMENT.
FIRST THREE DIGITS OF THE NETMASK DEF 000
SECOND THREE DIGITS OF THE NETMASK DEF 000
LAST THREE DIGITS OF THE NETMASK DEF 000
GATEU GATEWAY TO WHICH CONNECT THE INSTRUMENT.
FIRST THREE DIGITS OF THE GATEWAY ADDRESS DEF 000
SECOND THREE DIGITS OF THE GATEWAY ADDRESS DEF 000
LAST THREE DIGITS OF THE GATEWAY ADDRESS DEF 000
MAC MAC ADDRESS ASSIGNED TO THE INSTRUMENT.
FIRST COUPLE OF DIGITS OF MAC ADDRESS DEF 00
SECOND COUPLE OF DIGITS OF MAC ADDRESS DEF 00
THIRD COUPLE OF DIGITS OF MAC ADDRESS DEF 00
FOURTH COUPLE OF DIGITS OF MAC ADDRESS DEF 00
FIFTH COUPLE OF DIGITS OF MAC ADDRESS DEF 00
SIXTH COUPLE OF DIGITS OF MAC ADDRESS DEF 00

Comes back to the view mode, by pressing the ESC key, or if do not pressing any key within 5 seconds. To
obtain the data to set here refers to the industrial plant analyst, if not provided by ELETTRONDATA.

5.11.7 RTC
To set the DATE and TIME of the dater and clock in the instrument, from IN menu, with the (arrow down)
key search RTC and press the (Enter) key.

RTC
GGMMAA There is the possibility of set the day, month and year of the dater in the instrument.
HHMM There is the possibility of set the hours and minutes of the clock in the instrument.

In this menu there is the possibility to set the DATE and the TIME of the dater and clock, necessary for the
instrument to execute the recordings made from the ALIBI MEMORY for each extractor that makes a weighed
in the scale. Remains also turned on the F Led for indication that is a FUNCTION, so not a measured quantity
but a generic numeric value.

"REPOR.TECH.PERS."
To access to the DATE and TIME parameters of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek RTC, then pressing the (Enter) key, the
GGMMAA parameters is displayed, it permit by the (arrow up) and (arrow down) keys, to set the DATE,
after two seconds will be displayed the current value of the day, month and year. With the (arrow up) and
(arrow down) keys set a valid date and press the (Enter) key. The instrument displays the HHMM
parameters, it permit by the (arrow up) and (arrow down) keys, to set the TIME, after two seconds will be
displayed the current value of the hours and minutes. With the (arrow up) and (arrow down) keys set a
valid time and press the (Enter) key. With the final confirmation do exits the RTC menu and returns to the IN
menu.

© 2012 ELETTRONDATA S.R.L.


Basic Functions 35

5.11.8 NOISE
To view the ANALOGICAL INPUT NOISE VALUE of the instrument, from IN menu, with the (arrow down)
key search NOISE and press the (Enter) key.

NOISE
nnn There is the possibility of view the RSM value of the noise into the analog input.
nnn There is the possibility of view the Picco-picco value of the noise into the analog input.
nnn For internal use Elettrondata, it displays the value of the noise into the analog input.

In this menu there is the possibility to view the ANALOGICAL INPUT NOISE VALUE read in input, onto the 9-
pin connector. Remains also turned on the F Led for indication that is a FUNCTION, so not a measured
quantity but a generic numeric value.

"REPOR.TECH.PERS."
To access to the DATE and TIME parameters of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek NOISE, then pressing the (Enter) key, the
RSM value is displayed, press the (Enter) key. The instrument displays the PICCO-PICCO value, press the
(Enter) key the O value is displayed, press the (Enter) key to come back to RSM value. Press the ESC key
to return to IN menu, press the ESC key again to exit the menu or press the (arrow up) and (arrow down)
keys to select another operating parameter.
Remember that more these values are lower than the system is more immune to external interference. If these
values are relevant please check the steps in INSTALLATION.

5.11.9 GRAVIT
To view the GRAVITY value for the calibraton of the instrument, from IN menu, with the (arrow down) key
search GRAVIT and press the (Enter) key.

GRAVIT
nnnnnn There is the possibility of view or set the gravity value for the calibration.

In this menu there is the possibility to set the value of GRAVITY associated with the location of the instrument
so as to change the default setting without changing the tare and gain values. Remains also turned on the F
Led for indication that is a FUNCTION, so not a measured quantity but a generic numeric value.

Please note that these values change the slope of the calibration curve.
The value of gravity of the instrument set for this menu is displayed for 2 seconds, after the type of
instrument, the release software and the checksum value, before switching the weight display.

"REPOR.TECH.PERS."
To access to the GRAVITY parameters of the instrument, simultaneously press the (arrow up) and
(arrow down) keys and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press
(Enter) key. The instrument requires a password PAS-0, set E and press (Enter) key. The instrument
visualize IN, with the (arrow up) and (arrow down) keys seek GRAVIT, then pressing the (Enter) key,
the (Enter) key, the default GRAVITY value is displayed, modify it, inserting the 6 ciphers without the
comma, based on values in the tables in Annex C, press the (Enter) key to confirm it. Press the ESC key to
return to IN menu, press the ESC key again to exit the menu or press the (arrow up) and (arrow down)
keys to select another operating parameter.

This mode meets the requirements of the standard OIML R76-1: 2006 (E) sections 4.1.2.6
With the Ministerial Decree of May 19, 1999 No 1326557, was established criteria for determining the areas
of gravity for weighing instruments whose performance is sensitive to gravity variations, for the proper
calibration of the same in areas other than those used.

© 2012 ELETTRONDATA S.R.L.


36 ED640 Instrument

Weighing instruments that are equipped with functions for the gravity compensation can be set at a location is
correct for the acceleration of gravity of the place where it is used. The criteria for determining the areas of
gravity for the use of weighing instruments non-automatic, and whose performance is sensitive to gravity
variations are given in Annex C.

6 Operating Modes
To set the parameters for the OPERATING of the instrument, from the FUN-0 menu, with the (arrow up)
key, search FUN-E and press (Enter) key. The instrument requires a password "PAS-0", set "E" and press
(Enter) key. From IN menu, press the (Enter) key.Following are explained the parameters of this instrument
that you can access and modify.

- FUN=E INSTRUMENT INPUT TYPE PAS = E IN IN = X


Substituting for X the values between 0 and F gives the following configurations:

0 1 2 3 4 5 6 7
POT. 0-10V 0-5V 0-2.5V 0-1.25V 0-750mV 0-300mV 0-150mV
8 9 A B C D E F
0-75mV ? 0-800mV 0-400mV 0-200mV 0-55mV 0-25mV COUNTER

Note:
The value 0 refers to potentiometer input.
The values from 1 to 4 refer to voltage inputs.
The values from 5 to 8 relate to load cells with 6 wires or with reference.
The values from A to E refer to load cells with 4 wires or differential.
The value F refers to counter input in which, the digital inputs are enabled.

Once correctly programmed the instrument, you should write down the parameters for an easy recovery of the
same. In Annex B is placed a table to report the parameters.

"REPOR.TECH.PERS."
To access to the INPUT TYPE parameter, simultaneously press the (arrow up) and (arrow down) keys
and the (enter) key, enter in FUN-0 with (arrow up) key seek FUN-E and press (Enter) key. The
instrument requires a password PAS-0, set E and press (Enter) key. The instrument visualize IN, press the
(Enter) key. The instrument visualize IN-x, where x is the letter or number associated to the analog input type
of the instrument, to use. In case you want to access in the protected menu (shown in red) with the
homologable version of the instrument, you must follow the correct procedure, otherwise the instrument
comes back to FUN-E.

7 Calibration
"REPOR.TECH.PERS."
PROCEDURES TO PERFORMING THE INSTRUMENT CALIBRATION
Should be perform the calibration sequence after 15-20 minutes that the instrument is turned on, so as
to enable electronic components to reach thermal equilibrium.

TARE
Ensure that the system to be evaluated is empty and in the instrument were set full scale and decimal point
parameters.

Proceed as follows:
- access the CAL-5 function and press (Enter).
- appears the ZERO message, press (Enter) key to confirm the empty condition or 0 (zero) of the measure
scale.
- if there are not errors, appears the DONE message and it goes back to CAL-0, press (up arrow) key to
select CAL-6, or press ESC to exit the calibration parameters and return in view mode. Otherwise refer to
MESSAGES and repeat the procedure.

© 2012 ELETTRONDATA S.R.L.


Calibration 37

GAIN
Permit to calibrate the instrument with a sample quantity. To have a good accuracy of the calibration is
recommended to use a sample quantity equivalent to the next full scale set. Calibrations performed with
samples of less than 50% of full scale produce a degradation of accuracy. At the start-up that function should
be performed only after using the TARE function. In a second step can be performed individually to perform
subsequent adjustments of the indication, if they should be required (change of inclination of the straight line
calibration).

Proceed as follows:
- access the CAL-6 function and press (Enter).
- appears 000000.
- put the sample quantity on the system to be evaluated, near to F.S.
- press (Enter), it moves the selection on the display to the right, to select the digit to modify and with the
(up arrow) and (arrow down) keys set the correct value and press (Enter) till the end of the digits, press
(Enter) again to confirm the value setted. The ESC key moves the selection on the digit to the left. If it arrives
at the digit units, next press the ESC key exits from the setup without saving the data.
- If there are not errors, the instrument will go into display indicating the sample value, otherwise refer to
MESSAGES and repeat the procedure.

At calibration occurred is possible to stabilize the indication by acting on the FILTER function.
Note: In the condition in which you want to tweak the tare for the presence, for example, of residues of
material fixed in the system to evaluate, you can rerun the function of TARE mind that this merely refers to the
entire range of calibration function of the new value (the straight line calibration slide up or down without
changing slope).
Where changes are made to the system which cause significant changes on the input signal (eg, replacement
of the load cells) is necessary to rerun the entire calibration sequence (TARE + GAIN).

7.1 Thresholds
SETUP AND OPERATION OF THE THRESHOLDS
There are two programmable thresholds, a minimum and a maximum. At each threshold is an indication Led
and a relay contact output normally open.
Warning! If you enable PEAK, the operation changes.

MINIMUM THRESHOLD S1 ( )
It is active below of the set-point: Led turn on, open contact.
The Led indication , at left in the front panel, is turned on, for views under the value set and turned off for
views above it. The contact of the relay output to terminals 1 - 2 (S1) is closed for views above the set-point
and opened for views under it.

SETTING THE SET-POINT S1


- Maintain pressed the (enter) key to visualize the set-point S1 of minimum and flashing Led indication .
- With the (arrow up) and (arrow down) keys set the desired value.
- Release the (enter) key to store the new value and return to view.

MAXIMUM THRESHOLD S2 ( )
It is active above the set-point: Led turn on, open contact.
The Led indication , at right in the front panel, is turned on, for views above the value set and turned off for
views under it. The contact of relay output at terminals 2 - 3 (S2) is closed for views under the set-point and
opened for views above it. Sometimes is open to display alarms or changing settings.

SETTING SET-POINT S2
- Maintain pressed the ESC key to visualize the set-point S2 of maximum and flashing LED indication .
- With the (arrow up) and (arrow down) keys set the desired value.
- Release the ESC key to store the new value and return to view.

© 2012 ELETTRONDATA S.R.L.


38 ED640 Instrument

7.2 Stable weight


This instrument is not considered capable of providing a reliable reading if it can not turn on the LED of
STABLE WEIGHT, so it can not use any of the following functions:
Manual tare
Memorization in Alibi Memory
Semi-Automatic Zero-Setting
Zero-tracking
Suppression of negative

In this regard, the FILTER has been modified and this parameter is fixed at 1 division:
a) with time of 1 second to FIL-1, 2,3
b) with 2 seconds to FIL-4, 5,6
c) with time of 4 seconds to FIL-7
d) with time of 8 seconds to FIL-8.
While presenting the same delays as before, providing continuous readings allows the LEDs go out when the
weight stable weight (filtered) changes without having to wait for the time average filter.
If you can not get the weight stable during the reading of the quantity to be stored in ALIBI MEMORY
intervenes automatically the raising of FILTER to store the data valid, at the end of that this value back to the
previous setting.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) sections 4.4.2, 4.4.6, 4.5.6, 4.5.7,
4.6.8 e A.4.12

7.3 Zero-setting device


The instrument has more than one Zero-setting device the weight for excess or for deficiency.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) section 4.5 and subsections.
Described as:
T.2.7.2 Zero-setting device
Device for setting the indication to zero when there is no load on the load receptor.

7.3.1 Tare device


If the device has turn on the LED of STABLE WEIGHT these operations are possible.

To achieve the reset of the display are possible following the first hand, the second automatic:
1. When pressed for 2 seconds, the TARA allows you to enable, turning on the NET Led. The next press
allows you to disable (restoration of previous weight), turning off the LED,, the manual tare.
2. When I performed the steps in the menu FUN-4.
Immediately eliminating automatic tare you if you fall below 90% of the tare setting.
This value is also displayed in FUN-5 - CAL-C.
Is not settable manually a negative tare.
3. When the amount in balance drift for reasons not attributable to the instrument.
4. When the amount in the balance is negative, within the limits.

Ending this operation in manual or in automatic, the NET Led is always turn on.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) section 4.5, 4.6 and subsections.
Described as:
T.2.7.2.1 Nonautomatic zero-setting device
Device for setting the indication to zero by an operator.

© 2012 ELETTRONDATA S.R.L.


Calibration 39

7.3.2 Semi-Automatic Zero-Setting


Pressing the ZERO key determines the zeroed of the quantity displayed with an accuracy of at least one
quarter of the division of the instrument. This zeroed is subject to the following conditions:
The quantity must be stable; LED of Stable weight lit on.
The quantity must be referred to full scale. The range is between -2% and +2% or +/-50% if not metric;
Not to be included any manual tare.

The adjustments resulting from pressing shall be subject to the following restrictions:
Not saved, then by turning the tool are lost.
Overall corrections not exceed ±2% of the maximum weighing capacity and never alters the ability to read
the Full Scale set.

The Semi-Automatic Zero-Setting function is activated after 2 seconds of pressing the key displaying "|-0-|",
must press the (Enter) key to confirm it. If you press the (Enter) key but there are conditions to enable (is
not set the stable weight or are outside the range allowed), the function is not activated. If you press the
(Enter) key and there are conditions to accept the Semi-Automatic Zero-Setting, shows the message DONE to
indicate that it was accepted. The display will show 0 and lights up the Zero-Indicating LED.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) section 4.5 and subsections.
Described as:
T.2.7.2.2 Semi-automatic zero-setting device
Device for setting the indication to zero automatically following a manual command.

7.3.3 Suppression of negative


The suppression of negative is automatic if the following conditions are met:
The quantity must be stable; LED of Stable weight lit on.
Not to be included any manual tare.

Example: If the Full Scale is 5000Kg the instrument automatically displays 0 (zero) after 5 seconds the weight
is Stable, if the negative does not exceed -100 kg.

The adjustments resulting shall be subject to the following restrictions:


Not saved, then by turning the instrument are lost.
Overall corrections not exceed ±2% of the maximum weighing capacity and never alters the ability to read
the Full Scale set.

If the negative value is beyond the scope of the AutoCorrect the instrument shows the negative maximum
value, you should verify the calibration in order to overcome this problem.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) section 4.5 and subsections.
Described as:
T.2.7.2.3 Automatic zero-setting device
Device for setting the indication to zero automatically without the intervention of an operator.

7.4 Zero-tracking
The Zero-tracking device is Automatic, and fixed to 0.5d/s, if the following conditions are met:
The quantity must be stable; LED of Stable weight lit on.
If the instrument displays zero or a quantity around zero of Tara, less or equal a division.

Example: If 1 division is equivalent to 1 kg the instrument automatically displays 0 (zero) after the weight is
Stable, if the deviation per every second passed, does not exceed the 0,5 kg.

© 2012 ELETTRONDATA S.R.L.


40 ED640 Instrument

Always turns off the Zero-Indicating LED.


The adjustments resulting shall be subject to the following restrictions:
Not saved, then by turning the tool are lost.
Overall corrections not exceed ±2% of the maximum weighing capacity and never alters the ability to read
the Full Scale set.

"RIFER.PERS.TECN."
This mode meets the requirements of the standard OIML R76-1: 2006 (E) sections 4.5.6 and 4.5.7
Described as:
T.2.7.3 Zero-tracking device
Device for maintaining the zero indication within certain limits automatically.

8 Messages
ERROR MESSAGES
In case of errors the tool takes the analog output to the maximum value (+10Vdc) and enables the S2
maximum threshold ( ) and thus its contact, to indicate an anomaly. If the instrument displays only the
increase of quantity, verify that FUN=5 - CAL=B is set to PIC=0. If the visualization of the errors described
not disappears performing the Resolution procedure contact the Customer Support.

ERROR CAUSE RESOLUTION


Return the setting of the parameter Full Scale to the
Full Scale too high compared to the
Err.=1 correct values or act on the parameter Moltiplier so
number of divisions.
as to adapt the input signal to adjust the Full Scale.
Few divisions compared to full scale.
Check the value of the input signal or connections to
The input signal may be too high to have
Err.=2 the instrument. It is advisable to act on the Moltiplier
a sufficient number of divisions to reach
in order to adapt the input signal to the Full Scale.
the FULL SCALE.
Check the value of the input signal or connections to
Too many divisions compared to full
the instrument. It is advisable to act on the Moltiplier
scale. The input signal may be too low to
Err.=3 in order to adapt the input signal to the Full Scale or
have an adequate number of divisions for
amplify the signal from the field to obtain larger
the FULL SCALE set.
excursion of the input signal.
The A/D converter does not respond to Try turning off and on, the power supply to the
Err.=4 queries of the CPU. In this case the instrument, if it returns, send the instrument for
instrument is locked. Customer Support.
Try turning off and on, the power supply to the
Errors in storage of the data
Err.=5 instrument, if it returns, send the instrument for
configuration .
Customer Support.
You are trying to set a parameter linearization lower
Errors in programming of the
Err.=6 than the previous. Press ESC to exit and enter a
linearization.
correct point.
You are trying to achieve a calibration reserved.
Err.=7 Errors in setting the calibration.
Press ESC to exit the function.

© 2012 ELETTRONDATA S.R.L.


Compliance Statement 41

9 Compliance Statement

© 2012 ELETTRONDATA S.R.L.


42 ED640 Instrument

© 2012 ELETTRONDATA S.R.L.


Compliance Statement 43

© 2012 ELETTRONDATA S.R.L.


44 ED640 Instrument

© 2012 ELETTRONDATA S.R.L.


Compliance Statement 45

© 2012 ELETTRONDATA S.R.L.


46 ED640 Instrument

© 2012 ELETTRONDATA S.R.L.


Compliance Statement 47

© 2012 ELETTRONDATA S.R.L.


48 ED640 Instrument

10 General Conditions

GUARANTEE
9 months from starting up. The guarantee will not cover a period of over 12 months from the date in which the
material is notified as being ready, unless otherwise agreed in the product Sales Contract. The guarantee
covers the replacement of parts that prove to be faulty and the labour requested for repairing them, on
condition that the goods are returned to ELETTRONDATA on a free port basis. Should the user request the
presence of a technician, the journey, board and lodging expenses and daily allowance will be charged but not
the time requested for the repair work. The user may not claim any refund for downtime or refunds and
indemnities for expenses or direct and indirect damage. For productions where even a brief machine stoppage
cannot be tolerated, it is indispensable to have a supply of necessary spare-parts.
THE GUARANTEE WILL NOT APPLY IN THE EVENT THAT THE EQUIPMENT HAS BEEN TAMPERED
WITH, REPAIRED WITHOUT AN AUTHORISATION, INSTALLED BY PERSONNEL NOT AUTHORISED IN
WRITTEN FORM, IMPROPERLY SERVICED, GO SUBJECT TO ELECTRICAL DISCHARGES OR ANY
OTHER EVENT WHICH DOES NOT FALL UNDER THE RESPONSIBILITY OF ELETTRONDATA.
At the end of the guarantee period, the assistance and repair commitments relating explicitly or implicitly to the
supply of our products will no longer apply. Stipulating an appropriate contract with ELETTRONDATA may
however extend the guarantee conditions or assistance commitments.

LIABILITIES
The product may be used for internal factory statistic, accounting and checking purposes only, as they have
not been type approved as suitable for protecting public faith (art. 692 of the Italian penal code). The use of the
devices in relation to third parties is therefore PROHIBITED, without prejudice to instructions to the contrary if
given. Before confirming the order, the user is therefore responsible for assessing and checking whether the
product suits the use it is intended for.
By using the product described in this documentation, the Customer accepts the fact that it is an
programmable, electronic and intrinsically complex system that may not be totally error free.
Any expenses for type approval or certifications that are not mentioned in the supply are at the entire charge of
the user. ELETTRONDATA refuses any liability for improper use of its products. The programmes are supplied
on a user software basis, unless otherwise arranged, and, in the state in which they are delivered, are
provided with a user licence provided by ELETTRONDATA. The purchaser may not lay claims for the source
versions of programmes that are property of ELETTRONDATA. The latter reserves the right to modify or
improve its programmes without giving prior notice. The latter reserves the right to modify or improve its
programmes without giving prior notice. ELETTRONDATA will in any case undertake to provide any updates at
their sales price. It is the user’s responsibility to use all its endeavours to guarantee the confidentiality of the
programmes and documents sold to it on a user licence basis, as established by the EEC 91/250 norm and the
DPR 518-31/12/1992.
IN NO CASE WILL ELETTRONDATA ACCEPT LIABILITIES FOR DIRECT OR CONSEQUENTIAL
DAMAGES ARISING OUT OF THE USE OF ALL OR PART OF THE SOFTWARE, EQUIPMENT AND
DOCUMENTS PROVIDED.

© 2012 ELETTRONDATA S.R.L.


Support 49

11 Support

Via del Canaletto, 77/79


41042 Spezzano di Fiorano
(Modena) Italia
Tel. : +39 ( 0536 ) 1840500
Fax : +39 ( 0536 ) 1840501

After-Sales Service Direct Dial number:


Call the above number, listen to the voice message, select After-Sales Service by pressing the right button,
listen to the new voice message and press the button for the type of Service required.

Web Site: www.elettrondata.it


E-Mail: help&support@elettrondata.it

The after-sales service is provided by ELETTRONDATA or its certified, trained service centres1.

Telephone after-sales service is only provided on technical aspects, in response to the problem described.
The after-sales service does not include advice on products or types of plant.
When requesting service, be ready to state:
1. Your name and position;
2. The plant’s supply details.
3. Te serial number and release of the instrument.
Anonymous enquiries, or those not linked to ELETTRONDATA Customers, are not accepted.
Work to be done on the customer’s premises or at ELETTRONDATA is agreed by means of a quotation on paper or an
electronic medium. The after-sales service will not be supplied for problems:
1. Which can be solved by simply consulting this documentation;
2. Deriving from the use of programmes not supplied by ELETTRONDATA.
3. Deriving from the use of products not supplied by ELETTRONDATA.

1 For the list of authorised service centres, go to www.elettrondata.it, Dealers – Installers, in the SERVICE menu.

© 2012 ELETTRONDATA S.R.L.


50 ED640 Instrument

12 Annex A
CHANGING MODES OF OPERATING

Warning!!!
Perform this procedure on a table disconnecting each connector,
the VDE power supply, the 8-pin connector, the 9-pin connector input
and the Ethernet connector if it is available on the instrument.

"REPOR.TECH.PERS."
To access Jumper unscrew the four screws on the rear of the instrument, remove the electronic boards from
the container, being careful to not damage any components mounted on them. Hold the instrument with the
connector 8-pole facing left and check the proper placement of jumpers.

The one next to the relay, red rectangle, change the serial RS232, by default, in RS485, moving on to face,
positioned opposite to the integrate. For setting the parameters of serial refer to BASIC FUNCTIONS - FUN-E
- SER.
The one next to the 9-pin connector, blue rhombus, removing it change the type of analog output from 0-10V,
by default, in 0-20mA. The setting OUT=1, in the OUT menu, allows to have the output in 4-20mA or 2-10V.

Summing up the analog output may have four modes:


1) Default jumper, OUT=0 analog output 0-10V
2) Default jumper, OUT=1 analog output 2-10V
3) Jumper removed, OUT=0 analog output 0-20mA
4) Jumper removed, OUT=1 analog output 4-20mA

To connect an instrument ED640 set in current to a voltage input, such as a digital multimeter, MUST be fitted
with a 500 Ohm resistor (better to use 499 ohm resistors 1%). Not mount the resistance directly on the
terminal of the ED640. After making changes to the jumpers with due attention to restore the electronic boards
inside the container and screw the back panel before reconnecting the connectors and socket VDE.

© 2012 ELETTRONDATA S.R.L.


Annex A 51

12.1 Annex A1
INTERFERENCE SUPPRESSION
Warning!!!
Perform this procedure on a table disconnecting each connector,
the VDE power supply, the 8-pin connector, the 9-pin connector input
and the Ethernet connector if it is available on the instrument.
For the suppression of certain types of electromagnetic disturbances that may occur during the operation of
the plant, most of all in electrical panels with inverter or with not optimal grounded, or with the instrument
positioned in the vicinity of power cables, can be entered in the sensitive cables of the instrument such as
serial cable and load cells cable, some ferrites.

"REPOR.TECH.PERS."
For requesting these components contact the service SUPPORT.
Take a cable at a time and make it run around the ferrite once or twice depending on the possibilities of the
case. It is recommended where possible to make it run around twice. Reconnect the connectors: 8-pin orange
(where is the serial) and 9-pin female (where is the load cell), and last the VDE for the power supply.

The picture shows an example of the result of the intervention.

© 2012 ELETTRONDATA S.R.L.


52 ED640 Instrument

13 Annex B
SERIAL NUMBER INSTRUMENT
__________

PLANT SCALE
__________
PLANT
DEFAULT PARAMETR
PARAMETER
LOAD CELL POT. 0-10V INPUT
ED640
IN = E IN = 0 IN = 1 IN = ___
FUN-5 CAL-1 FILTER 0 0 0
FUN-5 CAL-2 DECIMAL POINT xxxxx xxx.xx xxx.xx
FUN-5 CAL-3 MOLTIPLIER 1 1 1
FUN-5 CAL-4 FULL SCALE 5000 50.00 50.00
FUN-5 CAL-8 ANALOG ZERO 0 0 0
FUN-5 CAL-9 ANALOG F.S. 4086 4086 4086
FUN-5 CAL-A SERIAL ADDRESS 0 0 0
FUN-9 eCAL-1 DA0D 0 0 0
FUN-9 eCAL-2 tLOC 0 0 0
FUN-E OUT 0-10V (0-20mA) 0 0 0
FUN-E SER 9600 N 8 1 9600 N 8 1 9600 N 8 1 9600 N 8 1
FUN-E SER TRA-2 PRT-0 TRA-2 PRT-0 TRA-2 PRT-0 TRA-2 PRT-0
FUN-E ETHERN IP ADDRESS 000.000.000 000.000.000 000.000.000
FUN-E ETHERN NETMASK 000.000.000 000.000.000 000.000.000
FUN-E ETHERN GATEWAY 000.000.000 000.000.000 000.000.000
ADDRESS
FUN-E ETHERN MAC ADDRESS 00.00.00.00.00.00 00.00.00.00.00.00 00.00.00.00.00.0
0
THRESHOLD S1 10 0.10 0.10
THRESHOLD S2 4500 45.00 45.00
COMPLETION DATE ___________
SIGNATURE COMPILER ___________

© 2012 ELETTRONDATA S.R.L.


Annex C 53

14 Annex C
AREAS OF GRAVITY OF UTILIZATION
TABLE 1
Correspondence between gravity zones, designation codified, g and associated measurement characteristics.

AREAS OF GRAVITY NAME CODIFIED g ASSOCIATED MAXIMUM NUMBER DIVISIONS


OF UTILIZATION CLASS I CLASS II CLASS III CLASS IIII
Entire country ITALY 9,80149 m/s² 300 300 1000
A (*) ZONE A 9,80655 m/s² 1000 3000
B ZONE B 9,80237 m/s²
C ZONE C 9,80129 m/s²
Sicily 2 SICILY 2 9,79819 m/s²
Territory of a province NAME OF g provincial capital 2000 6000
(**) PROVINCE
Place of installation NAME OF TOWN Calibration in the Any 100000 10000
place of installation

(*) For the region Aosta Valley the calibration of scales up to 1000 divisions (class II) and 3000 divisions (Class
III), is made with reference to the capital Aosta g value (see Table 3 below).
(**) Excluding the provinces of Aosta and Catania. For the scales installed on their territory the area of gravity
is the place of installation.

TABLE 2
g value of the zone A, B, C, SICILY 2. To recover the g value of the utilizing area of the instrument refer to the
local metric officer.

ZONA A ZONA B ZONA C SICILIA 2


EMILIA ROMAGNA ABRUZZO BASILICATA AGRIGENTO
FRIULI VENEZIA GIULIA CAMPANIA CALABRIA CALTANISETTA
LIGURIA LAZIO SARDINIA CATANIA
LOMBARDY MOLISE SICILY 1: ENNA
MARCHE APULIA MESSINA RAGUSA
PIEDMONT PALERMO SYRACUSE
TUSCANY TRAPANI
TRENTINO ALTO ADIGE
UMBRIA
VENETO

TABLE 3
g values of the provinces. To recover the g value of the utilizing area of the instrument refer to the local metric
officer. Suitable for weighing instruments with Divisions >=6000.

CHIEF TOWN GRAVITY m/s² CHIEF TOWN GRAVITY m/s²


AGRIGENTO 9,79823 MESSINA 9,80082
ALEXANDRIA 9,80496 MILAN 9,80505
ANCONA 9,80402 MODENA 9,80416
AOSTA (*) 9,80375 NAPLES 9,80296
AREZZO 9,80389 NOVARA 9,80471
ASCOLI PICENO 9,80317 NUORO 9,80027
ASTI 9,80471 ORISTANO 9,80172
AVELLINO 9,80175 PADOVA 9,80652
BARI 9,80324 PALERMO 9,80054
BELLUNO 9,80562 PARMA 9,80427

© 2012 ELETTRONDATA S.R.L.


54 ED640 Instrument

BENEVENTO 9,80247 PAVIA 9,80481


BERGAMO 9,80471 PERUGIA 9,80314
BIELLA 9,80437 PESARO 9,80439
BOLOGNA 9,80419 PESCARA 9,80326
BOLZANO 9,80548 PIACENZA 9,80459
BRESCIA 9,80456 PISA 9,80513
BRINDISI 9,80270 PISTOIA 9,80500
CAGLIARI 9,80096 PORDENONE 9,80629
CALTANISSETTA 9,79676 POTENZA 9,79970
CAMPOBASSO 9,80092 PRATO 9,80484
CASERTA 9,80265 RAGUSA 9,79769
CATANIA (*) 9,80040 RAVENNA 9,80440
CATANZARO 9,80002 REGGIO CALABRIA 9,80063
CHIETI 9,80237 REGGIO EMILIA 9,80414
COMO 9,80516 RIETI 9,80264
COSENZA 9,80120 RIMINI 9,80439
CREMONA 9,80511 ROME 9,80352
CROTONE 9,80084 ROVIGO 9,80605
CUNEO 9,80264 SALERNO 9,80269
ENNA 9,79571 SASSARI 9,80184
FERRARA 9,80447 SAVONA 9,80559
FLORENCE 9,80483 SIENA 9,80380
FOGGIA 9,80267 SYRACUSE 9,80034
FORLI’ 9,80435 SONDRIO 9,80534
FROSINONE 9,80246 TARANTO 9,80231
GENOA 9,80559 TERAMO 9,80269
GORIZIA 9,80636 TERNI 9,80359
GROSSETO 9,80425 TURIN 9,80577
IMPERIA 9,80508 TRAPANI 9,80052
ISERNIA 9,80161 TRENTO 9,80596
L’AQUILA 9,80129 TREVISO 9,80631
LA SPEZIA 9,80552 TRIESTE 9,80653
LATINA 9,80330 UDINE 9,80609
LECCE 9,80247 VARESE 9,80451
LECCO 9,80519 VENEZIA 9,80631
LIVORNO 9,80516 VERBANIA 9,80544
LODI 9,80491 VERCELLI 9,80465
LUCCA 9,80516 VERONA 9,80644
MACERATA 9,80318 VIBO VALENTIA 9,79916
MANTUA 9,80520 VICENZA 9,80643
MASSA 9,80508 VITERBO 9,80294
MATERA 9,80072

© 2012 ELETTRONDATA S.R.L.


Annex C 55

TABLE 4
g values of the major cities of the world.
To recover the g value of the utilizing area of the instrument refer to the local metric officer.

CHIEF TOWN GRAVITY


Amsterdam 9,81300 m/s²
Istanbul 9,80800 m/s²
Paris 9,80900 m/s²
Athens 9,80000 m/s²
Havana 9,78800 m/s²
Rio de Janeiro 9,78800 m/s²
Auckland 9,79900 m/s²
Helsinki 9,81900 m/s²
Bangkok 9,78300 m/s²
Kuwait 9,79300 m/s²
San Francisco 9,80000 m/s²
Brussels 9,81100 m/s²
Lisbon 9,80100 m/s²
Singapore 9,78100 m/s²
Buenos Aires 9,79700 m/s²
London 9,81200 m/s²
Stockholm 9,81800 m/s²
Calcutta 9,78800 m/s²
Los Angeles 9,79600 m/s²
Sydney 9,79700 m/s²
Cape Town 9,79600 m/s²
Madrid 9,80000 m/s²
Taipei 9,79000 m/s²
Chicago 9,80300 m/s²
Manila 9,78400 m/s²
Tokyo 9,79800 m/s²
Copenhagen 9,81500 m/s²
Mexico City 9,77900 m/s²
Vancouver 9,80900 m/s²
Nicosia 9,79700 m/s²
New York City 9,80200 m/s²
Washington, DC 9,80100 m/s²
Jakarta 9,78100 m/s²
Oslo 9,81900 m/s²
Wellington 9,80300 m/s²
Frankfurt 9,81000 m/s²
Ottawa 9,80600 m/s²
Zurich 9,80700 m/s²

© 2012 ELETTRONDATA S.R.L.


56 ED640 Instrument

15 Counter Function
To use the COUNTER to follow the steps below.

TECHNICAL DATA

This mode of operation involves the use of:

Two opto-coupled digital inputs in screw terminal. Operating voltage 24VDC.


MAXIMUM PULSE COUNTING: 80 AT SECOND
Two relay contact outputs max 230Vac, with single common.
Analog output 0-10 VDC (2-10 VDC optional) or 0-20 mA (4-20 mA optional).
The serial connection.
The Ethernet connection.

CONNECTIONS

To use the analog output connect the following pins on the connector 9pin:

PIN 4 EXC-; Analog output negative signal.


PIN 6 AOUT; Analog output positive signal.

If you do not want to use the analog output shall be used the SERIAL or ETHERNET link.

To use the COUNTER connect the following screw terminals:

SCREW TERMINAL 6 gnd; common ground signal for opto-coupled inputs.


SCREW TERMINAL 7 Encoder; for 24VDC input signal pulses.
SCREW TERMINAL 8 Start; to reset the counter by the 24VDC external signal.

The minimum and maximum thresholds are also used.

PARAMETERS

To use the COUNTER function correctly set the Operating Modes.

- FUN-E TYPE OF INSTRUMENT INPUT PAS = E IN IN = F


The F value refers to counter input when the digital inputs are enabled.

The value resulting on the anolog output depends from the OUT parameter and on the procedure in Annex A.
Remains proportional to the value set in Full Scale. Example: if set in 100.0Kg F.S. with analogue output 0-
10V, each pulse corresponds to 0.1 kg and output, then 1mV.

To reset the counter you can also use FUN-2.

Note: When programmed correctly, the instrument you should write down the parameters for easy recovery of
the same. A table in Annex B to report the parameters.

OPERATION

The start of counting has to the arrival of pulses up to the quantity to dose or until it reaches the full scale set.
The view in the display follows as described in the Display visualizations. The analog output is proportional
to the full scale and not to the quantity to dose. To reset the counter you can use the external contact or FUN-2
. Pressing the (up arrow) and (down arrow) keys and (enter) you enter the FUN-0 menu, with the (up
arrow) key seek FUN-2 and press (enter). When you reset the counter, the display and analog output will
return to zero.

© 2012 ELETTRONDATA S.R.L.


Index 57

Index -T-
Technical Characteristics 6, 7, 10
-A-
Annex A 50
-V-
Annex A1 51 versione 16
Annex B 52
Annex C 53

-B-
Basic Functions 15, 16, 17, 18, 25, 26, 29, 30
FUN-5 19, 20, 21, 22, 23, 24
FUN-9 26, 27, 28
FUN-E 31, 32, 33, 34, 35

-C-
Calibration 36, 37, 38, 39
Zero-setting device 38, 39
Calibrazione 38
Compliance Statement 41
Connections 14
Counter Function 56

-E-
ED640 16

-G-
General Conditions 48
General Informations 4
Declaration of conformity 5
Handbook Revisions 4
Introduction 4

-I-
Installation 10

-M-
Messages 40
metrico 16

-O-
omologata 16
omologato 16
Operating Modes 36

-P-
Panels and Keyboard 11, 13

-S-
Service Centres 49
Simbology 7, 8, 9
strumento 16
Support 49

© 2012 ELETTRONDATA S.R.L.