w-H2O Series

USW-3
ULTRASONIC WATER METER

• Class C
• Potable
water
metering,
0.1°C - 60°C
• No moving
components
• Tamper-proof
• Leak detection
• AMR ready
• Insensitive to sand,
sediment or
other particles
• Vacuum-sealed for
humidity resistance
• Long lifespan with
consistent performance

USW-3 represents the latest


innovation of USonic Metering’s
w-H2OTM inline ultrasonic water
meter series.

This smart meter, in accordance with


OIML R49, is designed specifically to
capture water consumption in residential
& commercial applications while
integrating into an AMR/AMI network
and billing solutions.

EACH AND EVERY


DROP COUNTS
Manufactured to be rugged, the USW-3 water meter has a sensor
body constructed of high quality brass. With no moving components,
once installed the meter remains accurate and maintenance free.
The non-obstructive sensor design leads to no blockage and
miniscule pressure drops. This robust design is ideal for challenging
environments such as those in desert applications.

With USonic METERING's USW-3


you can:
• Remain proactive and identify leakage in order
to capture lost revenue by detecting leaks as
low as a few drops per second.
• Guarantee enduring meter performance even
in harsh environments such as Middle East and
Africa, as the unit is insensitive to sand,
sedimentation and other particles.
• Reliably operate the unit with excellent long-
term stability backed by a 10 year warranty,
as accuracy does not degrade over time.
• Combat environmental elements with the
sand-proof and submersible IP68 enclosure.
• Reduce operational costs over the long run.
• Prevent condensation from display and
electronics due to vacuum-sealed design.
• Capture precise readings with robust ultra-
sonic transit-time technology.
• Ensure optimal field performance with a 15
year battery life.
• Register accurate readings as air is not measured.
• Detect reverse flow.
• Reliably integrate into AMR/AMI networking
solutions using M-Bus, radio and pulse.
• Automatically switch to power over M-Bus
when available to conserve battery.
• Remain confident with a tamperproof design.
• Reduce pump costs with our low pressure
drop design.
EACH AND EVERY
DROP COUNTS
Sales@USonicmetering.com
WAT E R

Nominal Overload Transitional Minimum Starting Pressure Loss


Size
Flowrate Q3 Flowrate Q4 Flowrate Q2 Flowrate Q1 Flowrate QS ΔP @ Q3
(mm) (in) (m3/h) (gpm) (m3/h) (gpm) (1/h) (gph) (1/h) (gph) (1/h) (gph) (Bar)
15 ½ 2.5 11 3.125 13.8 16 4.22 10 2.64 2 .52 0.63
20 ¾ 4 17.6 5 22 25.6 6.7 16 4.22 3 .79 0.40
25 1 6.3 27.7 7.8 34.3 40.3 10.6 25.6 6.7 4 1 0.25
32 1 1/4 10 44 12.5 55 64 16.9 40 10.5 6 1.5 0.25
40 1½ 16 70.4 20 96.8 102.4 27 60 15.8 8 2.1 0.25
50+ 2 Please check the big sizes and C & I datasheet.

Maximum Permissible Flow Meter Indication Error


OIML R 49-1 Class 2

OPERATING % of Flowrate

PRINCIPLE +5

+2
Flowrate
Using the ultrasonic Qs Q1 Q2 Q3 Q4
transit-time measuring -2

technology, emitted
-5
ultrasound beams are sent
back and forth between • USW-3 Provides Better Accuracy Than R49 Standard.

two ultrasonic transducers.


The liquid velocity is
determined by the Pressure Loss vs. Flowrate
difference in measured
transit-times between
beams sent into
(downstream) and against
(upstream) the direction of
liquid flow.

• Non-obstructive Sensor Design Guarantees Low Pressure Loss.

Sales@USonicmetering.com
EACH AND EVERY DROP COUNTS

Rated Operating Conditions


Maximum Admissible Pressure, Operating (MAP) : 16 bar (1.6 MPa)
Static Current : <10uA
Battery Life : 15 years
Network Power Supply: Automatically switch to M-Bus or
RS485 Power if available
Accuracy Class : Class 2 (OIML R49)
Metrology Class: Class C
Back Flow Detection : Yes
Operating Water Temperature :
Continuous operation : 0.1°C to 60°C (32°F to 140°F)
Ambient Class : Outdoor
Calculator Protection : IP68 waterproof, submersible
Flow Sensor Protection : IP68 waterproof, submersible
Pipe Joint Options : BSP or NPT
AMR Connectivity : M-Bus, Wireless M-Bus 433/868MHz, LORA, RS485/Modbus

Dimension:
Notes:
(1) Default pipe joint is BSP threading.
NPT threading is available upon request.
(2) L is flow sensor length. L2 is the total
of flow sensor plus extension pieces length
(3) Weight includes extension piece.
(4) 1m3/h is about 4.4 GPM.

About USonic Metering


USonic Metering is a global leader in flow and energy management solutions.
Through continuous innovation, we transform complex ultrasonic technology
into affordable, reliable solutions for accurate flow and energy measurement.