TD APP3 TD APP3
GEN .PCN GEN 1.PSN
iID
40 A
30 mA
iDT40T iDT40T iDT40T iDT40T iDT40T iDT40T
1P+N 1P+N 1P+N 1P+N 1P+N 1P+N
C16 A C16 A C16 A C6 A C6 A C16 A
L1 L3 L2 L3 L1
Ref-Mark PCN 4 PCN 5 Res GEN 1 .PSN IU 1 IU 2 HA
Socket 4 Socket 5 Power supply for
Share internal unit 1 (living Power supply for Power supply for hood
Denomination
room) internal unit 2 (kitchen)
Power (kW) 0,460kW 0,640kW 5,42kW 0,470kW 0,190kW 0,180kW
Power supply
Cable Type U1000R2V U1000R2V U1000R2V U1000R2V U1000R2V U1000R2V
Length (m) 20m 20m 20m 20m 20m 20m
Cable section (mm2) 3G2,5 3G2,5 3G2,5 5G6 3G2,5 3G2,5 3G2,5
Neutral
Separed
PE/PEN
Circuit breaker or iDT40T iDT40T iDT40T iID Type AC iDT40T iDT40T iDT40T
Switch disconnector
Rating (A) IDn (mA) 16 A 16 A 16 A 40 A 30mA 6A 6A 16 A
Ib (A) Ir (A)
Client Description Business code
Folio n°
3/6
Electrical distribution diagram
29/06/23 A The first edition
TD APP3 Date Rev. Description
TEL: (+237) 696 61 46 91
Designed: Checked: Approval: Scale:
Fixe: (+237) 233 03 35 94
BP: 8161 DOUALA
APARTMENTS BONAN O LOCATED IN CAMEROON Electrical distribution panel for apartment 3 (x11) KONLACK Loic FOUTSAP A. FOUTSAP A. without