Inductive proximity sensors

Cylindrical type, M30 x 1.5 threaded


Metal case (brass or stainless steel), form A
d.c. supply

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1
b
1.1 a

Lengths (mm) :
a = Overall a = 60
b = Threaded section b = 51.5

Brass case Stainless steel case Brass case

Nominal sensing distance (Sn) 10 mm 10 mm 10 mm

References

3-wire a PNP NO XS1-M30PA370 XS1-M30PA371 –

NC XS1-M30PB370 – –

NPN NO XS1-M30NA370 XS1-M30NA371 –

NC XS1-M30NB370 – –

4-wire a PNP/NPN NO/NC – – XS1-M30KP340


universal model programmable

Weight (kg) 0.205 0.205 0.205

Characteristics

Connection Pre-cabled, 3 x 0.34 mm2, length 2 m (1)

Degree of protection IP 68

Operating zone 0…8 mm


Repeat accuracy 3 % of Sr
Differential travel 1…15 % of Sr
Operating temperature - 25…+ 80 °C

Output state indication LED, annular

Rated supply voltage a 12…48 V a 12…24 V

Voltage limits (including ripple) a 10…58 V (3) a 10…38 V (4)

Switching capacity 0…200 mA with overload and short-circuit protection


Voltage drop, closed state ≤2V ≤ 2.6 V
Residual current, open state –
Current consumption, no-load ≤ 10 mA
Maximum switching frequency 1000 Hz
Delays First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Wiring schemes
3-wire a, NO or NC output 4-wire a programmable, NO or NC output
XS1-M30ii370/371/370D XS1-M30KP340/340D
BN/1 (NO), BU/3 (NC) BN/1 (NO), BU/3 (NC)
BN/1 + BN/1 + WH/2 + +
PNP BK/4 (NO) NPN PNP NPN
BK/2 (NC) BK/4 (NO) BK/4 WH/2
BK/2 (NC)
BU/3 – BU/3 – – BK/4 –
BU/3 (NO), BN/1 (NC) BU/3 (NO), BN/1 (NC)
Note : for XS1-M30ii370A sensors, NO or NC output on terminal 2
(1) Sensors pre-cabled with other cable lengths :
Length of cable Suffix to be added to references stated above for 2 m pre-cabled sensors Weight increase
5m L1 0.120 kg
10 m L2 0.320 kg
Example : sensor XS1-M30PA370 with 5 m cable becomes XS1-M30PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/4 to 3/6.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.

1/56 Te
1

1.1

a = 70 a = 75
b = 51.5 b = 54

Brass case Brass case Brass case

10 mm 10 mm 10 mm

XS1-M30PA370D – XS1-M30PA370A

XS1-M30PB370D – –

XS1-M30NA370D – XS1-M30NA370A

XS1-M30NB370D – –

– XS1-M30KP340D –

0.145 0.145 0.150

Connector (types 9, 10, 15, 16) (2) Connector (type 17) (2)

Depending on connector (see pages 3/4 to 3/6)

0…8 mm
3 % of Sr
1…15 % of Sr
- 25…+ 80 °C

LED, 4 viewing ports at 90° LED, side mounted

a 12…48 V a 12…24 V a 12…48 V

a 10…58 V (3) a 10…38 V (4) a 10…58 V (3)

0…200 mA with overload and short-circuit protection


≤2V ≤ 2.6 V ≤2V

≤ 10 mA
1000 Hz
First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)

e e
h

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m (brass case), < 100 N.m (stainless steel case)

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/57
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1

b
1.1 a

Lengths (mm) :
a = Overall a = 106 a = 71
b = Threaded section b = 51.5 b = 51.5

Nominal sensing distance (Sn) 10 mm 10 mm

References

3-wire a PNP NO XS1-M30PA370B XS1-M30PA370C

NC XS1-M30PB370B XS1-M30PB370C

NPN NO XS1-M30NA370B XS1-M30NA370C

NC XS1-M30NB370B –

Weight (kg) 0.165 0.185

Characteristics
Screw terminals, capacity : 2 x 1.5 mm2
Connection n° 11 plastic cable gland (capacity Ø 8 to 10 mm) Connector (type 21) (1)

Degree of protection IP 67 Depending on connector (see page 3/7)

Operating zone 0…8 mm

Repeat accuracy 3 % of Sr

Differential travel 1…15 % of Sr

Operating temperature - 25…+ 80 °C

Output state indication LED, side mounted

Rated supply voltage a 12…48 V

Voltage limits (including ripple) a 10…58 V (can be supplied with rectified c 24 V)

Switching capacity 0…200 mA with overload and short-circuit protection

Voltage drop, closed state ≤2V


Residual current, open state –
Current consumption, no-load ≤ 10 mA
Maximum switching frequency 1000 Hz

Delays First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Wiring schemes
3-wire a, NO or NC output
XS1-M30ii370B/370G/370T

BN/1 + BN/1 +
PNP BK/4 (NO) NPN
BK/2 (NC) BK/4 (NO)
BK/2 (NC)
BU/3 – BU/3 –
Note : for XS1-M30ii370C sensors, NO or NC output on terminal 2
(1) The type numbers refer to suitable female connectors, see pages 3/6 and 3/7.

1/58 Te
1

1.1

a = 75 a = 87
b = 51.5 b = 51.5

10 mm 10 mm

XS1-M30PA370G XS1-M30PA370T

– –

XS1-M30NA370G XS1-M30NA370T

– –

0.145 0.210

Connector (types 19 and 20) (1) Connector (type 22) (1)

Depending on connector (see pages 3/6 and 3/7)

0…8 mm

3 % of Sr

1…15 % of Sr

- 25…+ 80 °C

LED, annular LED, side mounted

a 12…48 V

a 10…58 V (can be supplied with rectified c 24 V)

0…200 mA with overload and short-circuit protection

≤2V

≤ 10 mA
1000 Hz

First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm) d
h

e e

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/59
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass or stainless steel), form A
d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Non flush mountable in metal


1

b c
1.1 a

Lengths (mm) :
a = Overall a = 60
b = Threaded section b = 38.5
c = For non flush mounting sensors c = 13
Brass case Stainless steel case Brass case

Nominal sensing distance (Sn) 15 mm 15 mm 15 mm

References

3-wire a PNP NO XS2-M30PA370 XS2-M30PA371 –

NC XS2-M30PB370 – –

NPN NO XS2-M30NA370 XS2-M30NA371 –

NC XS2-M30NB370 – –

4-wire a PNP/NPN NO/NC – – XS2-M30KP340


universal model programmable

Weight (kg) 0.205 0.205 0.205

Characteristics

Connection Pre-cabled, 3 x 0.34 mm2, length 2 m (1)

Degree of protection IP 68

Operating zone 0…12 mm


Repeat accuracy 3 % of Sr
Differential travel 1…15 % of Sr
Operating temperature - 25…+ 80 °C

Output state indication LED, annular

Rated supply voltage a 12…48 V a 12…24 V

Voltage limits (including ripple) a 10…58 V (3) a 10…38 V (4)

Switching capacity 0…200 mA with overload and short-circuit protection


Voltage drop, closed state ≤2V ≤ 2.6 V
Residual current, open state –
Current consumption, no-load ≤ 10 mA
Maximum switching frequency 1000 Hz
Delays First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Wiring schemes
3-wire a, NO or NC output 4-wire a programmable, NO or NC output
XS2-M30ii370/371/370D/370G/370T XS2-M30KP340/340D
BN/1 (NO), BU/3 (NC) BN/1 (NO), BU/3 (NC)
BN/1 + BN/1 + WH/2 + +
PNP BK/4 (NO) NPN PNP NPN
BK/2 (NC) BK/4 (NO) WH/2
BK/4
BK/2 (NC)
BU/3 – BU/3 – – BK/4 –
BU/3 (NO), BN/1 (NC) BU/3 (NO), BN/1 (NC)
Note : for XS2-M30ii370C sensors, NO or NC output on terminal 2
(1) Sensors pre-cabled with other cable lengths :
Length of cable Suffix to be added to references stated above for 2 m pre-cabled sensors Weight increase
5m L1 0.120 kg
10 m L2 0.320 kg
Example : sensor XS2-M30PA370 with 5 m cable becomes XS2-M30PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/4 to 3/7.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.

1/60 Te
1

1.1

a = 70 a = 71 a = 75 a = 87
b = 38.5 b = 38.5 b = 38.5 b = 38.5
c = 13 c = 13 c = 13 c = 13
Brass case Brass case Brass case Brass case Brass case

15 mm 15 mm 15 mm 15 mm 15 mm

XS2-M30PA370D – XS2-M30PA370C XS2-M30PA370G XS2-M30PA370T

XS2-M30PB370D – – – –

XS2-M30NA370D – XS2-M30NA370C XS2-M30NA370G XS2-M30NA370T

XS2-M30NB370D – – – –

– XS2-M30KP340D – – –

0.145 0.145 0.185 0.145 0.235

Connector (types 9, 10, 15, 16) (2) Connector (type 21) (2) Connector (types 19 and 20) (2) Connector (type 22) (2)

Depending on connector (see pages 3/4 to 3/7)

0…12 mm
3 % of Sr
1…15 % of Sr
- 25…+ 80 °C

LED, 4 viewing ports at 90° LED, side mounted LED, annular LED, side mounted

a 12…48 V a 12…24 V a 12…48 V

a 10…58 V (3) a 10…38 V (4) a 10…58 V (3)

0…200 mA with overload and short-circuit protection


≤2V ≤ 2.6 V ≤2V

≤ 10 mA
1000 Hz
First-up : ≤ 5 ms ; response : ≤ 0.3 ms ; recovery : ≤ 0.7 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)
d
h

e e

XS2 non flush mountable in metal e ≥ 60 e ≥ 180 e ≥ 45 d ≥ 90, h ≥ 30


Fixing nut tightening torque : < 50 N.m (brass case), < 100 N.m (stainless steel case)

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/61
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass or stainless steel), form A
d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1
b
1.1 a

Lengths (mm) :
a = Overall a = 50 a = 60
b = Threaded section b = 42 b = 40

Brass case Stainless steel case Brass case

Nominal sensing distance (Sn) 10 mm 10 mm 10 mm

References
2-wire a (non polarised)
Supply to : Terminals 3-4 NO XS1-M30DA210 XS1-M30DA211 XS1-M30DA210D

Terminals 1-4 NO – – XS1-M30DA214D

Terminals 1-2 NC XS1-M30DB210 XS1-M30DB211 –

Weight (kg) 0.205 0.205 0.145

Characteristics

Connection Pre-cabled, 2 x 0.5 mm 2, length 2 m (1) Connector (types 9, 10, 15, 16) (2)

Degree of protection IP 68 Dpg. on connector (see pages 3/4 and 3/5)

Operating zone 0…8 mm

Repeat accuracy 3 % of Sr

Differential travel 1…15 % of Sr

Operating temperature - 25…+ 80 °C

Output state indication LED, annular LED, 4 viewing ports at 90°

Rated supply voltage a 12…48 V

Voltage limits (including ripple) a 10…58 V

Switching capacity 1.5…100 mA with overload and short-circuit protection

Voltage drop, closed state ≤ 5.2 V

Residual current, open state ≤ 0.6 mA

Current consumption, no-load –

Maximum switching frequency 200 Hz

Delays First-up : ≤ 10 ms ; response : ≤ 2 ms ; recovery : ≤ 6 ms

Wiring schemes
2-wire a, non polarised, NO or NC output
XS1-M30DA210/DA211/DA210D/DA210LD/DA214D/DA214LD XS1-M30DB210/DB211/DB210LD XS1-M30Di210LA
BN/3 +/– BN/1 +/– 1 +/–
NO/NC
BN/1
/
NO NC
BU/4 –/+ BU/2 –/+ 2 –/+
(1) Sensors pre-cabled with other cable lengths :
Length of cable Suffix to be added to references stated above for 2 m pre-cabled sensors Weight increase
5m L1 0.120 kg
10 m L2 0.320 kg
Example : sensor XS1-M30DA210 with 5 m cable becomes XS1-M30DA210L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/4 to 3/6.

1/62 Te
1

1.1

a = 50 a = 50
b = 42 b = 42

Brass case Brass case

10 mm 10 mm

XS1-M30DA210LD XS1-M30DA210LA

XS1-M30DA214LD –

XS1-M30DB210LD XS1-M30DB210LA

0.170 0.185

Cable with moulded end connector, length of cable : 0.8 m Cable with moulded end connector, length of cable : 0.8 m
(types 9, 10, 15, 16, or splitter boxes) (2) (type 18) (2)

Depending on connector (see pages 3/4 to 3/6)

0…8 mm

3 % of Sr

1…15 % of Sr

- 25…+ 80 °C

LED, annular

a 12…48 V

a 10…58 V

1.5…100 mA with overload and short-circuit protection

≤ 5.2 V

≤ 0.6 mA

200 Hz

First-up : ≤ 10 ms ; response : ≤ 2 ms ; recovery : ≤ 6 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm) d

e e
h

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m (brass case), < 100 N.m (stainless steel case)

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/63
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1
b
1.1 a

Lengths (mm) :
a = Overall a = 106 a = 71
b = Threaded section b = 51.5 b = 51.5

Nominal sensing distance (Sn) 10 mm 10 mm

References

2-wire a NO XS1-M30DA210B XS1-M30DA210C


(non polarised)
NC XS1-M30DB210B –

Weight (kg) 0.165 0.185

Characteristics
Screw terminals, capacity : 2 x 1.5 mm2
Connection n° 11 plastic cable gland (capacity Ø 8 to 10 mm) Connector (type 21) (1)

Degree of protection IP 67 Depending on connector (see page 3/7)

Operating zone 0…8 mm

Repeat accuracy 3 % of Sr

Differential travel 1…15 % of Sr

Operating temperature - 25…+ 80 °C

Output state indication LED, side mounted

Rated supply voltage a 12…48 V

Voltage limits (including ripple) a 10…58 V

Switching capacity 1.5…100 mA with overload and short-circuit protection

Voltage drop, closed state ≤ 5.2 V

Residual current, open state ≤ 0.6 mA

Current consumption, no-load –

Maximum switching frequency 200 Hz

Delays First-up : ≤ 10 ms ; response : ≤ 2 ms ; recovery : ≤ 6 ms

Wiring schemes
2-wire a non polarised, NO or NC output
XS1-M30DA210B/210G/210T XS1-M30DB210B

3 +/– 1 +/–
NO NC
4 –/+ 2 –/+
Note : for XS1-M30DA210C sensors, connections to terminals 1 and 2
(1) The type numbers refer to suitable female connectors, see pages 3/6 and 3/7.

1/64 Te
1

1.1

a = 76 a = 87
b = 51.5 b = 51.5

10 mm 10 mm

XS1-M30DA210G XS1-M30DA210T

– –

0.145 0.235

Connector (types 19 and 20) (1) Connector (type 22) (1)

Depending on connector (see pages 3/6 and 3/7)

0…8 mm

3 % of Sr

1…15 % of Sr

- 25…+ 80 °C

LED, annular LED, side mounted

a 12…48 V

a 10…58 V

1.5…100 mA with overload and short-circuit protection

≤ 5.2 V

≤ 0.6 mA

200 Hz

First-up : ≤ 10 ms ; response : ≤ 2 ms ; recovery : ≤ 6 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)
d

e e
h

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/65
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
a.c. or d.c. supply

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1
b
1.1 a

Lengths (mm) :
a = Overall a = 60 a = 70
b = Threaded section b = 51.5 b = 51.5

AC/DC AC/DC

Nominal sensing distance (Sn) 10 mm 10 mm

References

2-wire c or a NO XS1-M30MA230 XS1-M30MA230K

NC XS1-M30MB230 XS1-M30MB230K

2-wire c or a NO XS1-M30MA250 XS1-M30MA250K


(protected against
short-circuits) NC XS1-M30MB250 XS1-M30MB250K

2-wire c NO – –

NC – –

Weight (kg) 0.205 0.145

Characteristics

Connection Pre-cabled, 2 x 0.5 mm 2, length 2 m (1) Connector (types 13 and 14) (2)
Degree of protection IP 68 Depending on connector (see page 3/5)

Operating zone 0…8 mm


Repeat accuracy 3 % of Sr
Differential travel 1…15 % of Sr
Operating temperature - 25…+ 80 °C
Output state non protected model LED, annular LED, 4 viewing ports at 90°
indication protected model 1 red LED (output state), 1 green LED (supply & s/c indic.) LED, 4 viewing ports at 90°

Rated supply voltage c 24…240 V (50/60 Hz) or a 24…210 V


Voltage limits (including ripple) c or a 20…264 V

Switching capacity (c) 5…300 mA or (a) 5…200 mA (3)


Voltage drop, closed state ≤ 5.5 V
Residual current, non protected model ≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V
open state protected model ≤ 1.5 mA
Current consumption, no-load –
Maximum switching frequency (c) 25 Hz or (a) 100 Hz
Delays First-up : ≤ 40 or ≤ 70 ms (models with short-circuit protection) ; response : ≤ 2 ms ; recovery : ≤ 5 ms

Wiring schemes
2-wire c or a, NO or NC output 2-wire c, NO or NC output
XS1-M30Mi230/250/230K/250K XS1-M30Mi2i0A XS1-M30Fi260
BN/2 1 BN

BU/3 3 BU

For connector version sensors


(1) Sensors pre-cabled with other cable lengths :
Length of cable Suffix to be added to references stated above for 2 m pre-cabled sensors Weight increase
5m L1 0.120 kg
10 m L2 0.320 kg
Example : sensor XS1-M30MA230 with 5 m cable becomes XS1-M30MA230L1
(2) The type numbers refer to suitable female extension cables, see pages 3/5 and 3/6.
(3) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
See page 3/0.

1/66 Te
1

1.1

a = 75 a = 60
b = 54 b = 51.5

AC/DC AC

10 mm 10 mm

XS1-M30MA230A –

XS1-M30MB230A –

XS1-M30MA250A –

XS1-M30MB250A –

– XS1-M30FA260

– XS1-M30FB260

0.150 0.205

Connector (type 18) (2) Pre-cabled, 2 x 0.5 mm2, length 2 m (1)


Depending on connector (see page 3/6) IP 68

0…8 mm
3 % of Sr
1…15 % of Sr
- 25…+ 80 °C
LED, side mounted LED, annular
1 red LED (output state), 1 green LED (supply and short-circuit indication) –

c 24…240 V (50/60 Hz) or a 24…210 V c 24…240 V (50/60 Hz)


c or a 20…264 V c 20…264 V

(c) 5…300 mA or (a) 5…200 mA (3) 5…300 mA (3) (2 A inrush)


≤ 5.5 V ≤ 4.5 V
≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V ≤ 1.5 mA
≤ 1.5 mA –
– –
(c) 25 Hz or (a) 100 Hz 25 Hz
First-up : ≤ 40 or ≤ 70 ms ; response : ≤ 2 ms ; recovery : ≤ 5 ms First-up : ≤ 40 ms ; response : ≤ 10 ms ; recovery : ≤ 15 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)

e e
h

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/67
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
a.c. or d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Flush mountable in metal


1

b
1.1 a

Lengths (mm) :
a = Overall a = 106 a = 71
b = Threaded section b = 51.5 b = 51.5

AC/DC AC/DC

Nominal sensing distance (Sn) 10 mm 10 mm

References

2-wire c or a NO XS1-M30MA230B XS1-M30MA230C

NC XS1-M30MB230B XS1-M30MB230C

Weight (kg) 0.165 0.185

Characteristics
Screw terminals, capacity : 2 x 1.5 mm2
Connection n° 11 plastic cable gland (capacity Ø 8 to 10 mm) Connector (type 21) (1)

Degree of protection IP 67 Depending on connector (see page 3/7)

Operating zone 0…8 mm

Repeat accuracy 3 % of Sr

Differential travel 1…15 % of Sr

Operating temperature - 25…+ 80 °C

Output state indication LED, side mounted

Rated supply voltage c 24…240 V (50/60 Hz) or a 24…210 V

Voltage limits (including ripple) c or a 20…264 V

Switching capacity (c) 5…300 mA or (a) 5…200 mA (2)

Voltage drop, closed state ≤ 5.5 V

Residual current, open state ≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V

Current consumption, no-load –

Maximum switching frequency (c) 25 Hz or (a) 100 Hz

Delays First-up : ≤ 40 ms ; response : ≤ 2 ms ; recovery : ≤ 5 ms

Wiring schemes
2-wire c or a , NO or NC output
XS1-M30ii230B, M30ii230G, M30ii230T XS1-M30ii230C

3 1 1

NO NC
4 2 2

For connector version sensors


(1) The type numbers refer to suitable female connectors, see pages 3/6 and 3/7.
(2) These sensors do not incorporate overload or short-circuit protection and therefore, it is recommended that a 0.8 A “quick-blow” fuse be connected in series
with the load. See page 3/0.

1/68 Te
1

1.1

a = 75 a = 87
b = 51.5 b = 51.5

AC/DC AC/DC

10 mm 10 mm

XS1-M30MA230G XS1-M30MA230T

XS1-M30MB230G –

0.145 0.235

Connector (types 19 and 20) (1) Connector (type 22) (1)

Depending on connector (see pages 3/6 and 3/7)

0…8 mm

3 % of Sr

1…15 % of Sr

- 25…+ 80 °C

LED, annular LED, side mounted

c 24…240 V (50/60 Hz) or a 24…210 V

c or a 20…264 V

(c) 5…300 mA or (a) 5…200 mA (2)

≤ 5.5 V

≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V

(c) 25 Hz or (a) 100 Hz

First-up : ≤ 40 ms ; response : ≤ 2 ms ; recovery : ≤ 5 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)
d

e e
h

XS1 flush mountable in metal e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


Fixing nut tightening torque : < 50 N.m

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/69
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
a.c. or d.c. supply (continued)

Accessories : References, characteristics, dimensions, schemes


page 3/0

Non flush mountable in metal


1

b c
1.1 a

Lengths (mm) :
a = Overall a = 60 a = 70 a = 75
b = Threaded section b = 38.5 b = 38.5 b = 41
c = For non flush mounting sensors c = 13 c = 13 c = 13
AC/DC AC/DC AC/DC

Nominal sensing distance (Sn) 15 mm 15 mm 15 mm

References

2-wire c or a NO XS2-M30MA230 XS2-M30MA230K XS2-M30MA230A

NC XS2-M30MB230 XS2-M30MB230K XS2-M30MB230A

2-wire c or a NO XS2-M30MA250 XS2-M30MA250K XS2-M30MA250A


(protected against
short-circuits) NC XS2-M30MB250 XS2-M30MB250K XS2-M30MB250A

Weight (kg) 0.205 0.145 0.150

Characteristics

Connection Pre-cabled, 2 x 0.5 mm2, L = 2 m (1) Connector (types 13 and 14) (2) Connector (type 18) (2)

Degree of protection IP 68 Depending on connector (see pages 3/5 and 3/6)

Operating zone 0…12 mm

Repeat accuracy 3 % of Sr
Differential travel 1…15 % of Sr
Operating temperature - 25…+ 80 °C

Output state non protected model LED, annular LED, 4 viewing ports at 90° LED, side mounted
indication 1 red LED (output state) 1 red LED (output state)
protected model 1 green LED (supply & s/c indication) LED, 4 viewing ports at 90° 1 green LED (supply & s/c indication)

Rated supply voltage c 24…240 V (50/60 Hz) or a 24…210 V

Voltage limits (including ripple) c or a 20…264 V

Switching capacity (c) 5…300 mA or (a) 5…200 mA (3)


Voltage drop, closed state ≤ 5.5 V
Residual current, non protected model ≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V
open state protected model ≤ 1.5 mA
Current consumption, no-load –
Maximum switching frequency (c) 25 Hz or (a) 75 Hz
Delays First-up : ≤ 40 or 70 ms (models with short-circuit protection) ; response : ≤ 2 ms ; recovery : ≤ 10 ms

Wiring schemes
2-wire c or a, NO or NC output
XS2-M30ii2i0, M30ii2i0K XS2-M30ii2i0A XS2-M30ii230C XS2-M30ii230G, M30ii230T
BN/2 1 1 3 1

NO NC
BU/3 3 2 4 2

For connector version sensors


(1) Sensors pre-cabled with other cable lengths :
Length of cable Suffix to be added to references stated above for 2 m pre-cabled sensors Weight increase
5m L1 0.120 kg
10 m L2 0.320 kg
Example : sensor XS2-M30MA230 with 5 m cable becomes XS2-M30MA230L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/5 to 3/7.
(3) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
See page 3/0.

1/70 Te
1

1.1

a = 71 a = 75 a = 87
b = 38.5 b = 38.5 b = 38.5
c = 13 c = 13 c = 13
AC/DC AC/DC AC/DC

15 mm 15 mm 15 mm

XS2-M30MA230C XS2-M30MA230G XS2-M30MA230T

XS2-M30MB230C XS2-M30MB230G –

– – –

– – –

0.185 0.145 0.235

Connector (type 21) (2) Connector (types 19 and 20) (2) Connector (type 22) (2)

Depending on connector (see pages 3/6 and 3/7)

0…12 mm

3 % of Sr
1…15 % of Sr
- 25…+ 80 °C

LED, side mounted LED, annular LED, side mounted

– – –

c 24…240 V (50/60 Hz) or a 24…210 V

c or a 20…264 V

(c) 5…300 mA or (a) 5…200 mA (3)


≤ 5.5 V
≤ 0.8 mA / 24 V or ≤ 1.5 mA / 120 V


(c) 25 Hz or (a) 75 Hz
First-up : ≤ 40 ms ; response : ≤ 2 ms ; recovery : ≤ 10 ms

Setting-up
Minimum mounting Side by side Face to face Facing a metal object Mounted in a metal support
distances (mm)
d

e e
h

XS2 non flush mountable in metal e ≥ 60 e ≥ 180 e ≥ 45 d ≥ 90, h ≥ 30


Fixing nut tightening torque : < 50 N.m

Other versions Inductive proximity sensors specifically designed for other ambient operating temperatures.
Please consult your local Customer support centre.

Te 1/71