INSPECTION NOTIFICATION (IN)
EPCC FOR PROVISION
                       OF NEW WATER
  PROJECT:                                                   CONTRACTOR PO No:                      -
                       TREATMENT PLANT IN
                       BLOCK 60
                           MAJEES TECHNICAL                                                         DELTA GULF OVERSEASE
  CONTRACTOR:                                                SUPPLIER / VENDOR:
                           SERVICES L.L.C.                                                          LLC
                                      EPCC
  Owner contract No              :                           IN No.          :    MTS-FAB/013/23-CIV-009 Rev 01
                                      4600008136
  EQPT TAG         :   -                                     ISSUE DATE                  :   20-10-2024
  INSPECTION NOTICE:         Contractor requests Owner presence according to the following schedule:
                         23-Oct-
  INSPECTION DATE:                      STARTING TIME:       09:00            DURATION: 10 Hrs
                          2024
  INSPECTION LOCATION          Al Al Shakhakhit Yard, Naseem Garden facility NGF-A
  (NAME, ADDRESS, TEL, EMAIL): 96782041, hamad@dletagulfo.com
  DISCIPLINE:                        Civil       Architectural        E&I         Mechanical     Piping     Pipeline
  Structural      Other
  TYPE OF INSPECTION:                PIM       Partial /Stage               FAT      Packing       Final          Other
  INSPECTION LEVEL:                   Review             Witness WitnessHold                                              Other
                                             Inspection of Reinforcement, Formwork, Concrete Pouring for
                                             Foundation and Pedestal
                                             ABB-17-CIV-GAR-MTS-08136-00006-00 (9 Nos)
                                             ABB-17-CIV-GAR-MTS-08136-00015-00 (6 Nos)
  ACTIVITY DESCRIPTION                  :
                                             ABB-17-CIV-GAR-MTS-08136-00021-00 (4 Nos)
                                             ABB-17-CIV-GAR-MTS-08136-00026-00 (4 Nos)
                                             ABB-17-CIV-GAR-MTS-08136-00029-00 (4 Nos)
                                             ABB-17-CIV-GAR-MTS-08136-00041-00 (4 Nos)
  REFERENCE DWG / SPEC                  :    03.01.29-Concrete_works-Specification Sec 8, 10 & 15
  ITP No.                                    ABB-17-QAC-ITP-MTS-08136-00017, K01
                                       :
  ACTIVITY No (s).                           4.1, 4.2, 4.7
  Attachments:
  COMMENTS / REMARKS:
  Project:
  WBS No:
                                              Hamad Zaidi, Project
                                              Engineer (Tel: +968-
  VENDOR REP (Print name and
                                              96782046),                          SIGNATURE:
  desig) :
                                              Email:hamad@deltagulfo.
                                              com,
                                              Arun Joy, QA-QC
  CONTRACTOR REP (Print name                  Engineer (Tel: +968
                                                                                  SIGNATURE:
  and desig):                                 93872539), Email:
                                              arunjoy@majeestech.com
Format no.: QA-FOM-0003 Rev-01                               Page 1 of 2
  COMPANY Inspector / QA-QC RESPONSE:
                                   Accepte                Acc with
  INSPECTION RESULT:                                                 Rejected     Postponed        Cancelled
                                   d                     comments
  QUALITY RECORD:                  Not Required        Required        Attached
  List of Quality records
  attached:
  COMMENTS / REMARKS:
  NAME (Print):                                   SIGNATURE:                    DATE:
  Notes:
     1. This section of IN is just for acknowledgement and shall not be interpreted as inspection record
         and / or acceptance of any inspection, examination or test. Acceptance can only be achieved
         by preparation and endorsement of the appropriate QC record which shall be attached hereto.
     2. Owner (TPI) endorsement of QC record will depend on actual inspection level, i.e. Hold Point /
         Witness. QC record shall be endorsed as “Witnessed” if attended or “Reviewed”, if not attended.
     3. It is the responsibility of Contractor and Supplier to obtain sign off of relevant quality records by
         Owner TPI where TPI assigned / visited supplier shop. TPI signed off quality records shall be part of
         final documentation / MDB.
  Company CLOSE OUT OF IN:
  Company QA/QC:
  COMMENTS:                      IN CLOSED
  NAME (Print):                                   SIGNATURE:                    DATE:
Distribution:   OWNER              CONTRACTOR