Wiring
Wiring
Schematic/Electrical Parts
36021, 36026, 42026 &
42030 V#Z
MilTouch Controls
PELLERIN MILNOR CORPORATION   POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.
                            Table of Contents
                           ME7V6Z11AE/23442A
1
    CB1             CIRCUIT CREAKER-HEAT/CONTROLS 36021/26 W7V6ZEH           09FC032CAA   IEC MINI CIR.BREAK 32A 480V3P D CURVE     CONTROL BOX
    CB1             CIRCUIT CREAKER-HEAT/CONTROLS 42026/30 W7V6ZEH           09FC050CAA   THERM MAG CIR.BREAK 50A 480V3P D CURVECONTROL BOX
    CR              >>RELAY-PILOT OR CONTROL
    CRC1            RELAY-FLUSH CHEMICAL #1               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRC2            RELAY-FLUSH CHEMICAL #2               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRC3            RELAY-FLUSH CHEMICAL #3               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRC4            RELAY-FLUSH CHEMICAL #4               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRC5            RELAY-FLUSH CHEMICAL #5               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRC6            RELAY-FLUSH CHEMICAL #6               W7V6ZCM            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRD             RELAY-OK TO OPEN DOOR                 W7V6ZS+            09C024D37    4PDT "KH" 110/120V                        START/RELAY BD
    CRD             RELAY-OK TO OPEN DOOR                 W7V6ZS+A           09C024D37    4PDT "KH" 110/120V                        START/RELAY BD
    CRDL            RELAY-DOOR CLOSED AND LOCKED          W7V6ZS+            09C024D37    4PDT "KH" 110/120V                        START/RELAY BD
    CRDL            RELAY-DOOR CLOSED AND LOCKED          W7V6ZS+A           09C024D37    4PDT "KH" 110/120V                        START/RELAY BD
    CRDRR           RELAY-DRAIN TO REUSE                  W7V6ZEV            09C024D37    4PDT "KH" 110/120V                        CONTROL BOX
    CRE             RELAY-OK TO LOCK DOOR                 W7V6ZS+A           09C024D37    4PDT "KH" 110/120V                        START/RELAY BD
    CS              >>CONTACTOR-MOTOR STARTER
    CSEH            CONTACTOR-ELECTRIC HEAT 36021/26      W7V6ZEV            09MC08L337   60A 3P MCS CONT NR 120V5/6                CONTROL BOX
    CSEH            CONTACTOR-ELECTRIC HEAT 42026/30      W7V6ZEV            09MC08T337   115A 3P MCS CONT. NR 120V5/6              CONTROL BOX
    CSVS            CONTACTOR-INVERTER 42V                W7V6ZS+A           09MC08J337   43A 3P MCS CONT NR 120V5/6                CONTROL BOX
                                                                     Page 1 of 4
                                                                                                                     W7V6ZPL/2021274N
                                            COMPONENT PARTS LIST
2
    EMCF        FAN-INVERTER COOLING              W7V6ZS+            13AF100A37   FAN 92CFM115V60 NEWARK#90F6921        CONTROL BOX
    EMCF        FAN-INVERTER COOLING              W7V6ZS+A           13AF100A37   FAN 92CFM115V60 NEWARK#90F6921        CONTROL BOX
    EMDL        SOLENOID-DOOR UNLOCK              W7V6ZS+            09K062B37    SOLENOID (C-7)120/60--110/50          DOOR LTCH BX
    EMDL        SOLENOID-DOOR UNLOCK              W7V6ZS+A           09K063C24    DOOR LOCK SOLENOID 24V                DOOR LOCK ASSY
    EMDR        SOLENOID-DRAIN VALVE              W7V6ZEV            96D350A37    DRINVAL 3"N/O MTRDR120V 50/60C NO COV/D BELOW SHELL
    ES          >>POWER SUPPLY-ELECTRONIC
    ESPS        POWER SUPPLY-MICROPROCESSOR       W7V6ZBW            08PSS3401T   40 WATT POWER SUPPLY TESTED           CONTROL BOX
    EX          >>TRANSFORMERS
    EX96A       TRANSFORMER-600V PRI/480V SEC     W7V6ZMT6           09US010A96   XFMR 1PH1.5KVA240/480X120/240         SIDE OF MACH
    EX96B       TRANSFORMER-600V PRI/480V SEC     W7V6ZMT6           09US010A96   XFMR 1PH1.5KVA240/480X120/240         SIDE OF MACH
    EXHV-1      TRANSFORMER-208/240>120VAC        W7V6ZLV            09UA025A37   XFMR 200-240PRI/120SEC 250V5/6        CONTROL BOX
    EXHV-2      TRANSFORMER-380/480>120VAC        W7V6ZLV            09UA025AAB   XFMR 380-480PRI/120-240SEC250V        CONTROL BOX
    INVERTER    INVERTER-4230V6Z <250V            W7V6ZVPA           09MWC04774   A1000 INVERTER 47 AMP                 CONTROL BOX
    INVERTER    INVERTER-4226V6Z <250V            W7V6ZVPA           09MWB03374   V1000 INVERTER 33AMP 230V             CONTROL BOX
    INVERTER    INVERTER-36"V6Z <250V             W7V6ZVPA           09MWB02574   V1000 INVERTER 25AMP 230V             CONTROL BOX
    INVERTER    INVERTER-4230V6Z >250V            W7V6ZVPA           09MWB01896   V1000 INVERTER 18AMP 460V             CONTROL BOX
    INVERTER    INVERTER-36"V5Z <250V             W7V6ZVPA           09MWB01774   V1000 INVERTER 17.5AMP 230V           CONTROL BOX
    INVERTER    INVERTER-36"V7Z >250V             W7V6ZVPA           09MWB01596   V1000 INVERTER 15AMP 460V             CONTROL BOX
    INVERTER    INVERTER-36"V5Z >250V             W7V6ZVPA           09MWB00996   V1000 INVERTER 9.2AMP 460             CONTROL BOX
                                                             Page 2 of 4
                                                                                                                         W7V6ZPL/2021274N
                                         COMPONENT PARTS LIST
3
    MVINV       INVERTER-3621/26V5Z HIGH VOLTAGE        W7V6ZVPA           09MWB00996   V1000 INVERTER 9.2AMP 460V         REAR CNT PANEL
    MVINV       INVERTER-3621/26V5Z HIGH VOLTAGE        W7V6ZVPA           09MWD00996   GA500 INVERTER 9.2 AMP 460V        REAR CNT PANEL
    MVINV       INVERTER-3621/26V7Z LOW VOLTAGE         W7V6ZVPA           09MWB03374   V1000 INVERTER 33AMP 230V          REAR CNT PANEL
    MVINV       INVERTER-3621/26V7Z LOW VOLTAGE         W7V6ZVPA           09MWD03374   GA500 INVERTER 33 AMP 230V         REAR CNT PANEL
    MVINV       INVERTER-3621/26V7Z HIGH VOLTAGE        W7V6ZVPA           09MWB01596   V1000 INVERTER 15AMP 460V          REAR CNT PANEL
    MVINV       INVERTER-3621/26V7Z HIGH VOLTAGE        W7V6ZVPA           09MWD01596   GA500 INVERTER 15AMP 460V          REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z LOW VOLTAGE         W7V6ZVPA           09MWB03374   V1000 INVERTER 33AMP 230V          REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z LOW VOLTAGE         W7V6ZVPA           09MWD03374   GA500 INVERTER 33 AMP 230V         REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z LOW VOLTAGE         W7V6ZVPA           09MWC04774   A1000 INVERTER 47 AMP              REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z LOW VOLTAGE         W7V6ZVPA           09MWD04774   GA500 INVERTER 47 AMP 230V         REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z HIGH VOLTAGE        W7V6ZVPA           09MWB01896   V1000 INVERTER 18AMP 460V          REAR CNT PANEL
    MVINV       INVERTER-4226/30V7Z HIGH VOLTAGE        W7V6ZVPA           09MWD01896   GA500 INVERTER 18 AMP 460V         REAR CNT PANEL
    RS          >>RESISTOR
    RS01        RESISTOR-POWER SUPPLY LOADING           W7V6ZBW            09AR16R25    RESISTOR 16 OHMS 25 WATTS          CONTROL BOX
    SH          >>SWITCH-HAND OPERATED
    SHDD        SWITCH-UNLATCH DOOR                     W7V6ZS+            09N405PB10   SWASS PBBK 1NO                     SWITCH PANEL
    SHDO        SWITCH-DOOR OPEN                        W7V6ZIA                         NOT USED
    SHES        SWITCH-OPTIONAL EMERGENCY STOP          W7V6ZS+            09N508       SW ASSY EMER STOP VERSION 3        SWITCH PANEL
    SHES        SWITCH-OPTIONAL EMERGENCY STOP          W7V6ZS+A           09N508       SW ASSY EMER STOP VERSION 3        SWITCH PANEL
                                                                   Page 3 of 4
                                                                                                                          W7V6ZPL/2021274N
                                          COMPONENT PARTS LIST
4
    TP1         PROBE-TEMPERATURE                     W7V6ZBW            30R0043P     TEMP PROBE:THERMISTOR 30K OHMS        BOTTOM OF SHELL
    VE          >>VALVE-ELECTRIC OPERATED
    VEC1        VALVE-FLUSH CHEM POCKET 1             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC2        VALVE-FLUSH CHEM POCKET 2             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC3        VALVE-FLUSH CHEM POCKET 3             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC4        VALVE-FLUSH CHEM POCKET 4             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC5        VALVE-FLUSH CHEM POCKET 5             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC6        VALVE-FLUSH CHEM POCKET 6             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC6        VALVE-STARCH TANK TO MACHINE          W7V6ZCF            96TAC3AA37   1/8" N/C 3WAY 120V50/60C VALVE        CONTROL BOX
    VEC6F       VALVE-STARCH TANK FLUSH               W7V6ZCF            96TAC3AA37   1/8" N/C 3WAY 120V50/60C VALVE        CONTROL BOX
    VEC7        VALVE-FLUSH CHEM POCKET 7             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEC8        VALVE-FLUSH CHEM POCKET 8             W7V6ZCF            --           CHEMICAL FLUSHING VALVE BY OTHERS     PWR CONN BX
    VEDR        VALVE-OPTIONAL ELECTRIC DRAIN         W7V6ZEV            96D350A37    DRINVAL 3"N/O MTRDR120V 50/60C        BELOW SHELL
    VEDRR       VALVE-DRAIN TO REUSE                  W7V6ZEV            96D350B37    DRAINVAL 3"N/C MTRDRV120V 50/6        BELOW SHELL
    VESTM       VALVE-STEAM                           W7V6ZEV            96R301A37    1/8" PILOT 3W-NC 110/50 120/60        AIR VALVE BX
    VEWC        VALVE-COLD WATER                      W7V6ZEV            96P056A37    3/4"NC 110V 50/60 W/LEADSBURK         SIDE OF MACH
    VEWH        VALVE-HOT WATER                       W7V6ZEV            96P056A37    3/4"NC 110V 50/60 W/LEADSBURK         SIDE OF MACH
    VEWVX       VALVE-EXTRA WATER                     W7V6ZEV            96P056A37    3/4"NC 110V 50/60 W/LEADSBURK         SIDE OF MACH
                                                                 Page 4 of 4
                     PELLERIN MILNOR CORPORATION
          LIMITED STANDARD WARRANTY
We warrant to the original purchaser that MILNOR machines including electronic hardware/software
(hereafter referred to as “equipment”), will be free from defects in material and workmanship for a
period of one year from the date of shipment (unless the time period is specifically extended for
certain parts pursuant to a specific MILNOR published extended warranty) from our factory with no
operating hour limitation. This warranty is contingent upon the equipment being installed, operated
and serviced as specified in the operating manual supplied with the equipment, and operated under
normal conditions by competent operators.
Providing we receive written notification of a warranted defect within 30 days of its discovery, we
will—at our option—repair or replace the defective part or parts, EX Factory (labor and freight
specifically NOT included). We retain the right to require inspection of the parts claimed defective in
our factory prior to repairing or replacing same. We will not be responsible, or in any way liable, for
unauthorized repairs or service to our equipment, and this warranty shall be void if the equipment is
tampered with, modified, or abused, used for purposes not intended in the design and construction
of the machine, or is repaired or altered in any way without MILNOR's written consent.
Parts damaged by exposure to weather, to aggressive water, or to chemical attack are not covered
by this warranty. For parts which require routine replacement due to normal wear—such as gaskets,
contact points, brake and clutch linings, belts, hoses, and similar parts—the warranty time period is
90 days.
We reserve the right to make changes in the design and/or construction of our equipment (including
purchased components) without obligation to change any equipment previously supplied.
ANY SALE OR FURNISHING OF ANY EQUIPMENT BY MILNOR IS MADE ONLY UPON THE EXPRESS
UNDERSTANDING THAT MILNOR MAKES NO EXPRESSED OR IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR USE OR PURPOSE OR ANY OTHER
WARRANTY IMPLIED BY LAW INCLUDING BUT NOT LIMITED TO REDHIBITION. MILNOR WILL NOT
BE RESPONSIBLE FOR ANY COSTS OR DAMAGES ACTUALLY INCURRED OR REQUIRED AS A RESULT
OF: THE FAILURE OF ANY OTHER PERSON OR ENTITY TO PERFORM ITS RESPONSIBILITIES, FIRE
OR OTHER HAZARD, ACCIDENT, IMPROPER STORAGE, MIS-USE, NEGLECT, POWER OR
ENVIRONMENTAL CONTROL MALFUNCTIONS, DAMAGE FROM LIQUIDS, OR ANY OTHER CAUSE
BEYOND THE NORMAL RANGE OF USE. REGARDLESS OF HOW CAUSED, IN NO EVENT SHALL
MILNOR BE LIABLE FOR SPECIAL, INDIRECT, PUNITIVE, LIQUIDATED, OR CONSEQUENTIAL COSTS
OR DAMAGES, OR ANY COSTS OR DAMAGES WHATSOEVER WHICH EXCEED THE PRICE PAID TO
MILNOR FOR THE EQUIPMENT IT SELLS OR FURNISHES.
THE PROVISIONS ON THIS PAGE REPRESENT THE ONLY WARRANTY FROM MILNOR AND NO OTHER
WARRANTY OR CONDITIONS, STATUTORY OR OTHERWISE, SHALL BE IMPLIED.
WE NEITHER ASSUME, NOR AUTHORIZE ANY EMPLOYEE OR OTHER PERSON TO ASSUME FOR US,
ANY OTHER RESPONSIBILITY AND/OR LIABILITY IN CONNECTION WITH THE SALE OR FURNISHING
OF OUR EQUIPMENT TO ANY BUYER.
BMP720097/19036
                                                  5
                                                                   How to Get the Necessary Repair Components
BIUUUD19 (Published) Book specs- Dates: 20081231 / 20081231 / 20081231 Lang: ENG01 Applic: UUU
You can get components to repair your machine from the approved supplier where you got this
machine. Your supplier will usually have the necessary components in stock. You can also get
components from the Milnor® factory.
Tell the supplier the machine model and serial number and this data for each necessary component:
 • The component number from this manual
 • The component name if known
 • The necessary quantity
 • The necessary transportation requirements
 • If the component is an electrical component, give the schematic number if known.
 • If the component is a motor or an electrical control, give the nameplate data from the used
    component.
To write to the Milnor factory:
   Pellerin Milnor Corporation
   Post Office Box 400
   Kenner, LA 70063-0400
   UNITED STATES
    Telephone: 504-467-2787
    Fax: 504-469-9777
    Email: parts@milnor.com
                                                — End of BIUUUD19 —
                                                      6
                                                                    How to Use Milnor® Electrical Schematic Diagrams
BIUUUK01 (Published) Book specs- Dates: 20130308 / 20130308 / 20130308 Lang: ENG01 Applic: PCR UUU
     CD=Control, Time Delay Relay (Figure 2)—A relay whose contacts switch only after a fixed
       or adjustable delay, once voltage has been applied to its coil. The contacts switch back to
       normal (de-energized state) immediately when the voltage is removed.
                                                          7
How to Use Milnor® Electrical Schematic Diagrams
CL=Control, Latch Relay (Figure 3)—A relay which latches in an energized or set position
  when operated by one coil (the latch/set coil). The relay stays latched even though coil voltage
  is removed. The relay releases or unlatches when voltage is applied to a second coil (the
  unlatch/reset coil).
CR=Control, Relay (Figure 4)—A relay whose contacts switch immediately when voltage is
  applied to its coil and revert to normal when the voltage is removed.
CP=Control, Photo-Eye (Figure 5)—Photo-eyes sense the presence of an object without direct
  physical contact. Photo-eyes consist of a transmitter, receiver, and output module. These
  components may be housed in one assembly with the transmitter bouncing light off of a
  reflector to the receiver, or these components can be housed in two separate assemblies with
  the transmitter pointed directly at the receiver. The photo-eye can be set to turn on its output
  either when the light beam becomes blocked (dark operate) or when it becomes un-blocked
  (light operate).
                                             8
                                                     How to Use Milnor® Electrical Schematic Diagrams
                                             9
How to Use Milnor® Electrical Schematic Diagrams
EX=Electrical Transformer (Figure 8)—A device that transfers electrical energy from one
  isolated circuit to another, often raising or lowering the voltage in the process.
KB=Keyboard—Device similar to a typewriter for making entries to a computer.
MN=Electronic Monitor (CRT)—A cathode ray tube used for visual presentation of data.
MR=Motors (Figure 9)—Electromechanical device that converts electrical energy into
  mechanical energy.
    Figure 8: Transformer (EX)                                     Figure 9: Electric Motor (MR)
MV=Motor (Variable Speed) Inverter—To vary the speed of an AC motor, the volts to
  frequency ratio must be kept constant. The motor will overheat if this ratio is not maintained.
  The motor variable speed inverter converts three phase AC to DC. The inverter then uses this
  DC voltage to generate AC at the proper voltage and frequency for the commanded speed.
        Note 2: Switch symbols used in the schematics and described below always depict the switch in its un-
        actuated state.
PX=Proximity Switch (Figure 10)—A device which reacts to the proximity of an target without
  physical contact or connection. The actuator or target causes a change in the inductance of the
  proximity switch which causes the switch to operate. Proximity switches can be two-wire
  (AC) or three-wire (DC) devices.
                                                     10
                                                   How to Use Milnor® Electrical Schematic Diagrams
SC=Switch, Cam Operated (Figure 11)—A switch in which the electrical contacts are opened
  and/or closed by the mechanical action of a cam(s). Applications include 35-50 pound timer
  operated machines, Autospot, timer reversing motor assembly, and some balancing systems.
SH=Switch, Hand Operated (Figure 12)—A switch that is manually operated (e.g., Start
  button, Master switch, etc.).
    Figure 11: Cam Switch (SC)        Figure 12: Hand Operated Switch
                                      (SH)
SK=Switch, Key Lock (Figure 13)—A switch that requires a key to operate. This prevents
  unauthorized personnel from gaining access to certain functions (e.g., the Program menu).
SL=Switch, Level Operated (Figure 14)—A switch connected to a float that causes the switch
  to open and close as the level changes.
    Figure 13: Key Switch (SK)        Figure 14: Level Switch (SL)
                                            11
How to Use Milnor® Electrical Schematic Diagrams
Figure 15: Mechanical Switch (SM) Figure 16: Pressure Switch (SP)
VE=Valve, Electric Operated (Figure 19)—A valve operated by an electric coil to control the
  flow of fluid. The fluid can be air, water or hydraulic.
Figure 19: Electrically Operated
Valve (VE)
ZF=Rectifier (Figure 20)—A solid state device that converts alternating current to direct
  current.
                                             12
                                                          How to Use Milnor® Electrical Schematic Diagrams
     WC=Wiring Connector—A coupling device for joining two cables or connecting a cable to an
      electronic circuit or piece of equipment. Connectors are male or female, according to whether
      they plug into or receive the mating connector.
                                                 13
How to Use Milnor® Electrical Schematic Diagrams
                                             14
                                                                   How to Use Milnor® Electrical Schematic Diagrams
            Note 3: Relay functional names ending with the letter "M" (e.g., CRxxM) are not discrete components but
            are a component of a printed circuit board. They are usually not individually replaceable.
                                                         15
How to Use Milnor® Electrical Schematic Diagrams
                                             16
                                                                How to Use Milnor® Electrical Schematic Diagrams
                                                       17
How to Use Milnor® Electrical Schematic Diagrams
     circuitry (S+=three-wire circuit) and establish the order in which the schematic occurs in the
     manual (schematics are arranged in alpha-numeric order in the manual).
     Whenever circuitry changes are significant enough to warrant publishing a new schematic
     drawing, the new drawing number will be the same as the old except for the major revision
     letter (A in the example).
2.   Included in the drawing title are the class of control system, the title of this circuit, and the
     circuit voltage.
3.   Line numbers are provided along the bottom edge of the drawing. These permit service
     personnel in the field and at the Milnor® factory to quickly relate circuit locations when
     discussing troubleshooting over the phone. Page and line numbers are referenced on the
     drawing as explained in items five and six below.
4.   Relay contacts show the page and line number on which the relay coil may be found. This is
     the type of cross referencing most frequently used in troubleshooting.
5.   Relay coils show the page and line number on which its associated contacts are located.
6.   Relay contacts and relay coils show the physical location of the relay.
7.   The designation MTA applies to electronic circuit board connections. Typically, a control
     system will contain several different types of circuit boards and one or more boards of each
     type. A numerical suffix identifies the board type and a numerical prefix identifies which one
     of several boards of a given type is being depicted. For example, the designation 1MTA5
     identifies this as the first I/O board (8 output, 16 input board) in the control system. As shown
     on the drawing, a pin number follows the board number, separated by a dash. Thus, 1MTA5-
     9 is pin 9 on this board. The numerical designations for board types vary from one control
     system to another. Some of the board types commonly encountered on the Mark V and Mark
     VI washer-extractor control and their designations are as follows:
       • MTM1-MTM8 = Mother board
       • MTA1-MTA5 = 8 output, 16 input (8/16) boards
       • MTA11-MTA14 = 24 output boards
       • MTA30-MTA40 = processor boards
       • MTA41-MTA43 = digital to analog (D/A) boards
       • MTA51-MTA55 = analog to digital (A/D) boards
       • MTA81-MTA85 = balance A-D board
   The complete listing of the boards utilized in a given control system can be found in the
   component list for that system.
8. Wire numbers, as described earlier in this section, are shown at appropriate locations on the
   schematic drawing.
9. Where diamond symbols appear at the end of a conductor, these are match points for
   continuing the schematic on another drawing. The page and line number that continues the
   circuit is printed adjacent to the diamond symbol. Where more than one match point appears
   on the referenced page, match diamonds containing corresponding letters.
                                         — End of BIUUUK01 —
                                             18
This page intentionally left blank.
                 19
                     Mass termination assembly
                        Pin number
    7      1MTA5-6
                     MTA designation on board
               Board MTA group designation
             An MTA is a connection on an
              electronic circuit board. The              Any relay that ends
             notes and the tag page locate                  with an "M" is
                 the appropriate board.                     located on an
                                                          electronic board.
                    Normally     Normally
                      closed      open
                    contacts     contacts
          7-1 contact S+09       S+11 7-4 contact
          8-2 contact            S+11 8-5 contact
          9-3 contact                   9-6 contact
          V-K contact                   V-Q contact
    Contact not used
   Drawing and line where
        contact is located
                                                            20
  This indicates on which
  page (W6DRYGS+) and
                              4
line number (08) the relay
 coil can be found for this
       set of contacts
                                   Major revision
                                      (letter)
                                    1   Page number
                                           (S+)
     8                          Machine type
  Wire identification marking. (Gas fired dryer)
       This designation is
  stamped on the wire every
   6 inches and is used with
    the signal routing table.
                                   6th generation
                                     of controls
W = Wiring
Page line
numbers        3
                                                         BMP010012 (right) / 2018343
                              21
22
23
                                          BBAD-1                                               INPUT LED LIGHTS
                                BALANCE A-D CONVERTER                                          I1-0 DOOR CLOSED
                                  FOR EXACT-XTRACT                                             I4-3 VIBRATION SW
                                                                                               I5-4 INVERTER FAULT
                                                              1                                I6-5 DR OPEN SW
              ADDITIONAL
                                     8 M5              M8           12 M6
               OUTPUTS
                                          1                              1
               1
                                   INVERTER
                                                      RS485                             TBA    I8-7 EXT FAULT
                                                                   INPUTS
                  M4
14
                                BIO
                                                                       INPUTS
                                                                         M7
                                                                                                                                              E          E
               1
                             CHEMICALS
                              OUTPUTS                ANALOG       DIGITAL                     O11-10 DRAIN                                    S   STDB   S
                                            +12VDC
                    16
                             T             TB1
                             B START CIRCUIT BOARD                                                            E   E
                                                                                                                                                     EXHV
                             2           NOT USED                                      G                                                       G
                                                                                                              F   F                      T T T
      SMWVB
                         MILTOUCHTM SYSTEMS
              36021, 36026V7Z/42026, 42030V6Z CONTROL
                               PANEL                                                                                                                  B2T2012010
                                                                                                                                                       2015435A
                                                     PELLERIN MILNOR CORPORATION
W7V6ZTG1
2015435B
                                                                                                 24
                                                                                                                                                                                                                                             W7V6ZTG1
                                                                                                                                                                                                                                             2015435B
                                                                                                                                                                                                     36 AND 42 V#Z MACHINE TAGS
                                                                                                                   INPUT LED LIGHTS
                                                                                         1                         I1-0 DOOR CLOSED
                                          ADDITIONAL
                                                                   8 M2          M8            12 M6
                             CD
                                           OUTPUTS
                                                                        1                           1
                                           1
                W                                                                                                  I6-5 DR OPEN SW
                                                                                                       14
                                                               BIO
                                                                                                  INPUTS
           CS
                                                                                                                   I8-7 EXT FAULT
                                                                                                    M7
                                                       INPUT/OUTPUT
       W                                                   BOARD                                            LEVEL
                                                                                                                   I9-8 TIMER STOP
                                                                                                 1
                                          STANDARD
                                                                                                            PRESSURE
                                          OUTPUTS
                                           1
                                                                                                                                                 INVERTER
                                             M3
CHEMICALS WCM
                                                                                                                                                                                          W7V6ZTG1
                                                         OUTPUTS                ANALOG       DIGITAL
                                                                       +12VDC
                                                16
                                                         1 M2                   INPUTS        GNDS
  OUTPUT LED LIGHTS
                                                                                                                                                                               RESISTOR
                                                              10        1 M1  1   MA         1 M9
  O1-0 TO O8-7 CHEM #1 TO 8                                                                                                                                            STDB
  O9-8 HOT WATER
  O10-9 COLD WATER                                                                                                                                                     TEMP
  O11-10 DRAIN                                                                             SELECT                                                                     SENSOR
  O12-11 FLUSH                                                                            240V--208V
  O13-12 COOLDOWN                                                                    TB3     SH01 T       ONLY USED
                                                                                                          ON 208-240V
                                                                       1MTD
                                                        ESPS
  O16-15 STEAM                                                                                      5
  O17-16 SPEED LIMIT (DOOR                                                         EF1
                                                                                                    T ONLY IF PULSE DOOR                                    EXHV
       UNLOCK IF PULSE DR)                                                          N/U             B INTERLOCK, IF PUSH
  O19-18 SPEED LIMIT IF
       PULSE DOOR
                                                                              START CIRCUIT BOARD 2
                                                                                   TB1
                                                                                                      DOOR INTERLOCK N/U
  O25-24 CW DIRECTION
  O26-25 CCW DIRECTION
  O27-26 ACC/DEC                                                                                                                         E   E
                                                                                                                         G
                                  SMWVB
                                                                                                                   T T T                 F   F
                                                                                                                         N TBA                   CSVP
                         A                                                                                         1 2 3                 P   P
           G TB                                                                                                          D
                                                                                                                                         1   2
         L N
       L   D
     L 2 3
     1
                                                               MICRO 6 SYSTEMS
                                                                36021, 36026V5Z                                                                                B2T2012011
         INCOMING POWER
SEPERATE BRANCH CIRCUIT PROTECTION                              CONTROL PANEL                                                                                   2015435A
                                                                                                                                                                                              W7V6ZTG1
                                                                                                                                                                                              2015435B
                                                                                                                       25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49