AR330
AR330
                                                                                      Interface
                                                                                                                              Tiltable 5.7-inch color LCD
                                                                                                                              Built-in thermal type line printer
                                                                                                                              (Easy loading and auto cutter)
                                                                                                                              RS-232C (IN / OUT)
                                                                                                                                                                                                                                                               AR-330A / 310A
                                                                                                                              USB
                                                                                                                              Eye care card system* *Card is optional
                                                                                                                                                                                                                                                                 AUTO REFRACTOMETER
                                                                                      Power supply                            AC100 - 240 V ±10 %
                                                             Easy Paper Loading                                               50 / 60 Hz
                                                                                      Power consumption                       100 VA
                                                                                      Dimensions & Weight                     260 (W) x 481(D) x 455 (H) mm / 20 kg
                                                                                                                              10.23 (W) x 18.93 (D) x 17.9 (H) " / 44.1 lbs.                                   HEAD OFFICE
                                                 Printed data sheet will be cut by    Standard accessories                    Spare printer paper, Power cord, Dust cover,                                     34-14 Maehama, Hiroishi
                                                 the auto cutter for quick and easy                                           Chinrest paper, Fixing pins, Model eye                                           Gamagori, Aichi 443-0038, Japan
                                                                                                                              Interface cable, Barcode scanner                                                 Telephone : 81-533-67-6611
                                                 detachment.                          Optional accessories
                                                                                                                                                                                                               Facsimile : 81-533-67-6610
                                                                                                                                                                                                               URL       : http://www.nidek.co.jp
                                                                                                                                                                                                               TOKYO OFFICE
                                                                                                                                                                                                               (International Div.)
                                                                                                                                                                                                               6F Takahashi Bldg.,
                         Auto Cutter                                                                                                                                                                           3-2 Kanda-Jinboucho
                                                                                                                                                                                                               Chiyoda, Tokyo 101-0051, Japan
                The desired data, such as the AR value, PD and confidence                                                                                                                                      Telephone : 81-3-3288-0571
                                                                                                                                                                                                               Facsimile : 81-3-3288-0570
                coefficient, as well as an eyeprint for documenting patient                                                                                                                                    URL        : http://www.nidek.com
                treatment, can be selected and printed out.
                                                                                                                                                                                                               NIDEK INC.
                                                                                                                                                                                                               47651 Westinghouse Drive
                                         Sample Printout            EyePrint                                                                                                                                   Fremont, CA 94539, U.S.A.
                                                                                                                                                                                                               Telephone : 1-510-226-5700
                                                                                                                                                                                                                          : 1-800-223-9044 (US only)
                                                                                                                                                                                                               Facsimile : 1-510-226-5750
                                                                                                                                                                                                               URL        : http://www.usa.nidek.com
        Excellent Measurement Accuracy                                                 Wide Measurement Range: -30 to +25D                                                                    3D* Auto Tracking & Auto Shooting
                                                                                                                                                                                                                                                                                       X direction
                                                                                                                                                                                                                                                                     FOCUS
                                                                                   The AR-330A / 310A offers the widest measurement range of -30 to +25D.                                The auto-alignment (X & Y directions), auto-focusing (Z
    Highly Accurate Refractometer                                                                                                                                                        direction) and auto-shooting provide faster, simpler and more
                                                                                                                                                                                         accurate measurements. When alignment is performed
    The combination of new measuring principle - Pupil Zone Imaging Method - and
    unique technology - SLD - offers high accuracy and reliability in refraction       Smallest Measurable Pupil Size: ø2mm                                                              correctly, measurement starts automatically.
                                                                                   The AR-330A / 310A can measure small pupils down to 2 mm in diameter, allowing wider                       Function        Auto Tacking
                                                                                                                                                                                                                                 Auto Shoot
    1. Pupil Zone Imaging Method                                                   application.                                                                                            Model             X-Y-Z       Y
                                                                                                                                                                                            AR-330A
    The NIDEK AR-330A / 310A adopts the advanced Pupil Zone
                                                                                                                                                                                            AR-310A
    Imaging Method for refraction measurement, which                                                         Informative 5.7-inch Tiltable Color LCD
    analyzes a wider area (Max. ø4 mm) to obtain more reliable
    and realistic data that is closer to manifest refraction.
                                                                                                         Clear image and data display with user-friendly guidance allow easier               Virtual Vision Comparison (AR-330A Only)
                  Measuring area comparison                                                              and more reliable operation. Projected double mire rings on the
                                                                                                         cornea helps better observation of the corneal shape and irregular              By pressing the Vision Comparison button, a virtual comparison
                                                                                                         astigmatism.                                                                    between patients' current vision (with the unaided eye or with
                                                                                                                   Thumbnailed image on CCD (AR-330A only), which can be enlarged by     glasses*) and AR-corrected vision can be easily demonstrated.
                                                                                                                   pressing button
       Conventional AR              AR-330A / 310A
                                                                                                                                                                                                   Current Vision
                                                                                                                                                                    Guidance mark to
    2. SLD (Super Luminescent Diode)                                                                                                                                lower the chinrest                                                               Better Vision
    The AR-330A / 310A uses the SLD (Super Luminescent Diode)
    and highly sensitive CCD device for improved image quality.
    The image with the SLD is sharper and clearer than those                                                                                                        Guidance mark to          Current vision with the            Virtual Vision
    with the LED, and the system offers greatly improved                                                                                                            move the main                  unaided eye                    Comparison
    measurement capability even with dense cataract and IOL                                                                                                         body toward the
                                                                                                                                                                    patient's eye
    implanted eyes.
                                                                                                                                                                                                                                                  AR-corrected vision
                Comparison of image on CCD*
        LED (Normal eye)              SLD (Normal eye)
                                                                                                                                                                                            Current vision with glasses*
Minimum pupil diameter mark Double mire rings *Requires data transfer from a NIDEK auto lensmeter.
                                                                                                                                                                                              Motorized Chinrest
       LED (Cataract eye)            SLD (Cataract eye)                                                                                                                                  The motorized chinrest with simple up / down
                                                                                                                                                The clear 5.7-inch color LCD with
                                                                                                                                                tilting function offers easy             buttons facilitates smoother operation.
                                                                                                                                                                                                                                                                              Up / down
                                                                                                                                                operation even for a standing
                                                                                                                                                                                                                                                                              buttons
                                                                                                                                                operator.
                                                                                                                                                                                              One-Touch Lock
                                                                                                                                                                                         The main body can be fixed with the
                                                                                                                            Tilting color LCD
               *In-house trial data (Model eye)                                                                                                                                          advanced one-touch lock.
Auto Refractometer
   AR-330A / 310A
                                                                                                                                                                                                                                                                             Y direction
        Excellent Measurement Accuracy                                                 Wide Measurement Range: -30 to +25D                                                                    3D* Auto Tracking & Auto Shooting
                                                                                                                                                                                                                                                                                       X direction
                                                                                                                                                                                                                                                                     FOCUS
                                                                                   The AR-330A / 310A offers the widest measurement range of -30 to +25D.                                The auto-alignment (X & Y directions), auto-focusing (Z
    Highly Accurate Refractometer                                                                                                                                                        direction) and auto-shooting provide faster, simpler and more
                                                                                                                                                                                         accurate measurements. When alignment is performed
    The combination of new measuring principle - Pupil Zone Imaging Method - and
    unique technology - SLD - offers high accuracy and reliability in refraction       Smallest Measurable Pupil Size: ø2mm                                                              correctly, measurement starts automatically.
                                                                                   The AR-330A / 310A can measure small pupils down to 2 mm in diameter, allowing wider                       Function        Auto Tacking
                                                                                                                                                                                                                                 Auto Shoot
    1. Pupil Zone Imaging Method                                                   application.                                                                                            Model             X-Y-Z       Y
                                                                                                                                                                                            AR-330A
    The NIDEK AR-330A / 310A adopts the advanced Pupil Zone
                                                                                                                                                                                            AR-310A
    Imaging Method for refraction measurement, which                                                         Informative 5.7-inch Tiltable Color LCD
    analyzes a wider area (Max. ø4 mm) to obtain more reliable
    and realistic data that is closer to manifest refraction.
                                                                                                         Clear image and data display with user-friendly guidance allow easier               Virtual Vision Comparison (AR-330A Only)
                  Measuring area comparison                                                              and more reliable operation. Projected double mire rings on the
                                                                                                         cornea helps better observation of the corneal shape and irregular              By pressing the Vision Comparison button, a virtual comparison
                                                                                                         astigmatism.                                                                    between patients' current vision (with the unaided eye or with
                                                                                                                   Thumbnailed image on CCD (AR-330A only), which can be enlarged by     glasses*) and AR-corrected vision can be easily demonstrated.
                                                                                                                   pressing button
       Conventional AR              AR-330A / 310A
                                                                                                                                                                                                   Current Vision
                                                                                                                                                                    Guidance mark to
    2. SLD (Super Luminescent Diode)                                                                                                                                lower the chinrest                                                               Better Vision
    The AR-330A / 310A uses the SLD (Super Luminescent Diode)
    and highly sensitive CCD device for improved image quality.
    The image with the SLD is sharper and clearer than those                                                                                                        Guidance mark to          Current vision with the            Virtual Vision
    with the LED, and the system offers greatly improved                                                                                                            move the main                  unaided eye                    Comparison
    measurement capability even with dense cataract and IOL                                                                                                         body toward the
                                                                                                                                                                    patient's eye
    implanted eyes.
                                                                                                                                                                                                                                                  AR-corrected vision
                Comparison of image on CCD*
        LED (Normal eye)              SLD (Normal eye)
                                                                                                                                                                                            Current vision with glasses*
Minimum pupil diameter mark Double mire rings *Requires data transfer from a NIDEK auto lensmeter.
                                                                                                                                                                                              Motorized Chinrest
       LED (Cataract eye)            SLD (Cataract eye)                                                                                                                                  The motorized chinrest with simple up / down
                                                                                                                                                The clear 5.7-inch color LCD with
                                                                                                                                                tilting function offers easy             buttons facilitates smoother operation.
                                                                                                                                                                                                                                                                              Up / down
                                                                                                                                                operation even for a standing
                                                                                                                                                                                                                                                                              buttons
                                                                                                                                                operator.
                                                                                                                                                                                              One-Touch Lock
                                                                                                                                                                                         The main body can be fixed with the
                                                                                                                            Tilting color LCD
               *In-house trial data (Model eye)                                                                                                                                          advanced one-touch lock.
Auto Refractometer
   AR-330A / 310A
                                                                                                                                                                                                                                                                             Y direction
        Excellent Measurement Accuracy                                                 Wide Measurement Range: -30 to +25D                                                                    3D* Auto Tracking & Auto Shooting
                                                                                                                                                                                                                                                                                       X direction
                                                                                                                                                                                                                                                                     FOCUS
                                                                                   The AR-330A / 310A offers the widest measurement range of -30 to +25D.                                The auto-alignment (X & Y directions), auto-focusing (Z
    Highly Accurate Refractometer                                                                                                                                                        direction) and auto-shooting provide faster, simpler and more
                                                                                                                                                                                         accurate measurements. When alignment is performed
    The combination of new measuring principle - Pupil Zone Imaging Method - and
    unique technology - SLD - offers high accuracy and reliability in refraction       Smallest Measurable Pupil Size: ø2mm                                                              correctly, measurement starts automatically.
                                                                                   The AR-330A / 310A can measure small pupils down to 2 mm in diameter, allowing wider                       Function        Auto Tacking
                                                                                                                                                                                                                                 Auto Shoot
    1. Pupil Zone Imaging Method                                                   application.                                                                                            Model             X-Y-Z       Y
                                                                                                                                                                                            AR-330A
    The NIDEK AR-330A / 310A adopts the advanced Pupil Zone
                                                                                                                                                                                            AR-310A
    Imaging Method for refraction measurement, which                                                         Informative 5.7-inch Tiltable Color LCD
    analyzes a wider area (Max. ø4 mm) to obtain more reliable
    and realistic data that is closer to manifest refraction.
                                                                                                         Clear image and data display with user-friendly guidance allow easier               Virtual Vision Comparison (AR-330A Only)
                  Measuring area comparison                                                              and more reliable operation. Projected double mire rings on the
                                                                                                         cornea helps better observation of the corneal shape and irregular              By pressing the Vision Comparison button, a virtual comparison
                                                                                                         astigmatism.                                                                    between patients' current vision (with the unaided eye or with
                                                                                                                   Thumbnailed image on CCD (AR-330A only), which can be enlarged by     glasses*) and AR-corrected vision can be easily demonstrated.
                                                                                                                   pressing button
       Conventional AR              AR-330A / 310A
                                                                                                                                                                                                   Current Vision
                                                                                                                                                                    Guidance mark to
    2. SLD (Super Luminescent Diode)                                                                                                                                lower the chinrest                                                               Better Vision
    The AR-330A / 310A uses the SLD (Super Luminescent Diode)
    and highly sensitive CCD device for improved image quality.
    The image with the SLD is sharper and clearer than those                                                                                                        Guidance mark to          Current vision with the            Virtual Vision
    with the LED, and the system offers greatly improved                                                                                                            move the main                  unaided eye                    Comparison
    measurement capability even with dense cataract and IOL                                                                                                         body toward the
                                                                                                                                                                    patient's eye
    implanted eyes.
                                                                                                                                                                                                                                                  AR-corrected vision
                Comparison of image on CCD*
        LED (Normal eye)              SLD (Normal eye)
                                                                                                                                                                                            Current vision with glasses*
Minimum pupil diameter mark Double mire rings *Requires data transfer from a NIDEK auto lensmeter.
                                                                                                                                                                                              Motorized Chinrest
       LED (Cataract eye)            SLD (Cataract eye)                                                                                                                                  The motorized chinrest with simple up / down
                                                                                                                                                The clear 5.7-inch color LCD with
                                                                                                                                                tilting function offers easy             buttons facilitates smoother operation.
                                                                                                                                                                                                                                                                              Up / down
                                                                                                                                                operation even for a standing
                                                                                                                                                                                                                                                                              buttons
                                                                                                                                                operator.
                                                                                                                                                                                              One-Touch Lock
                                                                                                                                                                                         The main body can be fixed with the
                                                                                                                            Tilting color LCD
               *In-house trial data (Model eye)                                                                                                                                          advanced one-touch lock.
                                                                                                                                                                                                                                         AR-330A / 310A
                                                                                      AR-330A / 310A Specifications
NIDEK's Innovative Auto Refractometer for                                             Auto refractometer
                                                                                       Measurable range                       Sphere
                                                                                                                                                       AR-330A
                                                                                                                                               -30.00D to +25.00D (VD=12 mm)
                                                                                                                                                                                          AR-310A
                                                                                      Interface
                                                                                                                              Tiltable 5.7-inch color LCD
                                                                                                                              Built-in thermal type line printer
                                                                                                                              (Easy loading and auto cutter)
                                                                                                                              RS-232C (IN / OUT)
                                                                                                                                                                                                                                                               AR-330A / 310A
                                                                                                                              USB
                                                                                                                              Eye care card system* *Card is optional
                                                                                                                                                                                                                                                                 AUTO REFRACTOMETER
                                                                                      Power supply                            AC100 - 240 V ±10 %
                                                             Easy Paper Loading                                               50 / 60 Hz
                                                                                      Power consumption                       100 VA
                                                                                      Dimensions & Weight                     260 (W) x 481(D) x 455 (H) mm / 20 kg
                                                                                                                              10.23 (W) x 18.93 (D) x 17.9 (H) " / 44.1 lbs.                                   HEAD OFFICE
                                                 Printed data sheet will be cut by    Standard accessories                    Spare printer paper, Power cord, Dust cover,                                     34-14 Maehama, Hiroishi
                                                 the auto cutter for quick and easy                                           Chinrest paper, Fixing pins, Model eye                                           Gamagori, Aichi 443-0038, Japan
                                                                                                                              Interface cable, Barcode scanner                                                 Telephone : 81-533-67-6611
                                                 detachment.                          Optional accessories
                                                                                                                                                                                                               Facsimile : 81-533-67-6610
                                                                                                                                                                                                               URL       : http://www.nidek.co.jp
                                                                                                                                                                                                               TOKYO OFFICE
                                                                                                                                                                                                               (International Div.)
                                                                                                                                                                                                               6F Takahashi Bldg.,
                         Auto Cutter                                                                                                                                                                           3-2 Kanda-Jinboucho
                                                                                                                                                                                                               Chiyoda, Tokyo 101-0051, Japan
                The desired data, such as the AR value, PD and confidence                                                                                                                                      Telephone : 81-3-3288-0571
                                                                                                                                                                                                               Facsimile : 81-3-3288-0570
                coefficient, as well as an eyeprint for documenting patient                                                                                                                                    URL        : http://www.nidek.com
                treatment, can be selected and printed out.
                                                                                                                                                                                                               NIDEK INC.
                                                                                                                                                                                                               47651 Westinghouse Drive
                                         Sample Printout            EyePrint                                                                                                                                   Fremont, CA 94539, U.S.A.
                                                                                                                                                                                                               Telephone : 1-510-226-5700
                                                                                                                                                                                                                          : 1-800-223-9044 (US only)
                                                                                                                                                                                                               Facsimile : 1-510-226-5750
                                                                                                                                                                                                               URL        : http://www.usa.nidek.com
                                                                                      Interface
                                                                                                                              Tiltable 5.7-inch color LCD
                                                                                                                              Built-in thermal type line printer
                                                                                                                              (Easy loading and auto cutter)
                                                                                                                              RS-232C (IN / OUT)
                                                                                                                                                                                                                                                               AR-330A / 310A
                                                                                                                              USB
                                                                                                                              Eye care card system* *Card is optional
                                                                                                                                                                                                                                                                 AUTO REFRACTOMETER
                                                                                      Power supply                            AC100 - 240 V ±10 %
                                                             Easy Paper Loading                                               50 / 60 Hz
                                                                                      Power consumption                       100 VA
                                                                                      Dimensions & Weight                     260 (W) x 481(D) x 455 (H) mm / 20 kg
                                                                                                                              10.23 (W) x 18.93 (D) x 17.9 (H) " / 44.1 lbs.                                   HEAD OFFICE
                                                 Printed data sheet will be cut by    Standard accessories                    Spare printer paper, Power cord, Dust cover,                                     34-14 Maehama, Hiroishi
                                                 the auto cutter for quick and easy                                           Chinrest paper, Fixing pins, Model eye                                           Gamagori, Aichi 443-0038, Japan
                                                                                                                              Interface cable, Barcode scanner                                                 Telephone : 81-533-67-6611
                                                 detachment.                          Optional accessories
                                                                                                                                                                                                               Facsimile : 81-533-67-6610
                                                                                                                                                                                                               URL       : http://www.nidek.co.jp
                                                                                                                                                                                                               TOKYO OFFICE
                                                                                                                                                                                                               (International Div.)
                                                                                                                                                                                                               6F Takahashi Bldg.,
                         Auto Cutter                                                                                                                                                                           3-2 Kanda-Jinboucho
                                                                                                                                                                                                               Chiyoda, Tokyo 101-0051, Japan
                The desired data, such as the AR value, PD and confidence                                                                                                                                      Telephone : 81-3-3288-0571
                                                                                                                                                                                                               Facsimile : 81-3-3288-0570
                coefficient, as well as an eyeprint for documenting patient                                                                                                                                    URL        : http://www.nidek.com
                treatment, can be selected and printed out.
                                                                                                                                                                                                               NIDEK INC.
                                                                                                                                                                                                               47651 Westinghouse Drive
                                         Sample Printout            EyePrint                                                                                                                                   Fremont, CA 94539, U.S.A.
                                                                                                                                                                                                               Telephone : 1-510-226-5700
                                                                                                                                                                                                                          : 1-800-223-9044 (US only)
                                                                                                                                                                                                               Facsimile : 1-510-226-5750
                                                                                                                                                                                                               URL        : http://www.usa.nidek.com