Kugelmann Kezelési
Kugelmann Kezelési
K-TRONIC
Control system
Subject to
Details menu 3
www.kugelmann.c
Table of contents
Explanations.................................................................................................................................................... 7
Error list......................................................................................................................................................... 12
Speed signal.................................................................................................................................................. 13
Sensor adjustment....................................................................................................................................... 15
Regulator adjustment..................................................................................16
Parameters.................................................................................................................................................... 16
Teach-in......................................................................................................................................................... 16
Characteristic curve..................................................................................................................................... 17
Error delay..................................................................................................................................................... 17
Mechanical limits.......................................................................................................................................... 18
Working range............................................................................................................................................... 19
Spreading materials.....................................................................................20
Subject to
4 Control system k-
tronic
Output counter.............................................................................................................................................. 22
Display increments....................................................................................................................................... 23
Spreading width...........................................................................................24
Setup screen: display increments............................................................................................................... 24
Options..........................................................................................................26
Temperature display..................................................................................................................................... 26
Display km/h.................................................................................................................................................. 26
Motor unit...................................................................................................................................................... 26
Brine equipment........................................................................................................................................... 28
Supplementary level....................................................................................30
Sub-menu item: Button MAX....................................................................................................................... 30
Spreading control......................................................................................................................................... 32
Subject to
Details menu 5
www.kugelmann.c
Protocol......................................................................................................................................................... 33
Speed reporting............................................................................................................................................ 34
Standstill message....................................................................................................................................... 34
Input functions.............................................................................................35
Activation of input functions....................................................................................................................... 35
Functions of inputs...................................................................................................................................... 35
Automatic locking......................................................................................................................................... 40
Double dosage.............................................................................................................................................. 40
Engli
Subject to
Engli 6 Control system k-
Subject to
Details menu 7
www.kugelmann.c
om
Explanations
User interface
Display appearing after switching on the control system k-tronic.
Turning knob
The control system k-tronic disposes of 3 turning knobs in the lower area. The turning knobs have no
internal/mechanical stop, they can be rotated continuously.
In addition, the turning knobs feature a push-button function. To actuate this button, the turning knob must be pressed
in the direction of the rotation axis.
The turning knobs have partly different functions within the different menu options. During turning the turning knob,
the value of the setup screens changes at the last digit. At many setup screens, the values can be modified with the
turning knob pressed; the setting value changes by factor 100 per detent.
At particular setup screens, the push-button of the turning knob triggers actions.
Button 1 to button 6
The control system k-tronic has 6 buttons.
The buttons have partly different functions within the different menu options. If a
button with a small symbol is displayed (e.g. button ), the button closest to the displayed symbol is
meant.
In certain cases, a different button must be pressed for a function (e.g. right and left shift key).
Button ON
The button ON at the control system k-tronic switches on and off the supply voltage of the spreader.
When switching on by means of the ON button, the spreader always starts at level 1 with operating mode .
The spreader starts also at level 1 even if the control system has been switched off at level 2.
When switching off by means of the ON button, all drive units will be stopped and all connected consumers
will be switched off.
Engli
Subject to
8 Control system k-
Menu
A menu consists of one or several menu lines. A further menu or a setup screen can be attached to a menu line.
Depending on the equipment of the spreader, individual menus may feature a lower number of menu items as
described here.
Go to a subjacent menu or setup screen by means of button 6 .
Soft switch
There are menu lines offering a 0/1 possibility to select. In such cases, the respective menu line is equipped with a so-
called soft switch. The setting is limited to “ON” ( ) or “OFF” ( ). The current switching status of the soft
switch is displayed in the respective menu line for review. With the menu line selected, the alternative switching
status is displayed at button 5.
Setup screen
A setup screen may be attached to the menu line. A setup screen is split into three columns, whereby values must not
be stored in all three columns. Always use the turning knob below to change values within a column. The modified
values of the setup screens are adopted and stored immediately.
With a menu line selected, go to the setup screen by means of button 6 .
Use button 4 to leave the setup screen.
If a large value range can be set in a column of the setup screen, the value may be changed by
factor 100 per detent by turning the pressed turning knob.
Engli
Subject to
Details menu 9
www.kugelmann.c
om
The details menu
During the first assembly of the spreader onto the carrier vehicle, settings, which are necessary for the correct
operation of the spreader, are made in the details menu. Also the individual options of the spreader are selected and
deselected here.
For safety reasons, the spreader must be in operating mode before entering the user
menu.
Press the button 6 for a short time to go back to the user menu.
Choose the line “Details menu” by means of the left turning knob , the line will be highlighted in
dark color. Then, press button 6 .
The same screen also shows the current software version of master and slave. The access code for the
Subject to
10 Control system k-
Error list
Display of last errors with a frequency counter.
Warning list
Display of last warnings with a frequency counter.
Speed signal
Adjustment of spreader to the speed signal of the carrier vehicle.
Sensor adjustment
Setting of sensors at the individual drives of the spreader.
Regulator adjustment
Presetting of regulation parameters for the operation of the spreader.
Spreading materials
Setting of pulses per kilogram for the left and right screw at the corresponding spreading materials.
Engli
Subject to
Details menu 11
Spreading width
Setting of spreading width at the mounted spreading disc.
Options
Possibility to carry out additional settings for operation.
Depending on the equipment of the spreader, it is also possible that less menu points are available in
this menu. For example, the menu point “adjustment of spreading pattern” is not available at all
spreaders.
Engli
Subject to
12 Control system k-
Error list
Up to 15 errors with frequency and order of appearance may be displayed in the error list. The latest error is
displayed on top of the list.
Frequency counter
If the same error occurs several times, the frequency counter is increased at each occurrence of the error. As soon as
another error occurs, the list will be extended by a new entry.
The display may be deleted by button 1. This means that errors which have occurred before deletion of the display
can no longer be shown by means of the control system. If no new errors occur until the next selection of the error
list, an empty list will be displayed.
Use button 4 to leave the error list - no entries will be deleted. If more than 15 errors have occurred in
different order, the older errors can no longer be displayed by the control system.
Warning list
Up to 15 warnings with frequency and order of appearance may be displayed in the warning list. The latest
warning is displayed on top of the list.
Frequency counter
If the same warning occurs several times, the frequency counter is increased at each occurrence of the warning. As soon
as another warning occurs, the list will be extended by a new warning.
Use button 1 to delete the warning display. This means that warnings which have occurred before deletion of the
display can no longer be shown by means of the control system. If no new warnings occur until the next selection of
the warning list, an empty list will be displayed.
Use button 4 to leave the warning list - no entries will be deleted. If more than 15 warnings have occurred
in different order, the older warnings can no longer be displayed by the control system.
If no new warnings have occurred since the last reset of the warning list, an empty list will be displayed.
Engli
Subject to
// DETAILS MENU
www.kugelmann.c
om
Speed signal
In order to guarantee correct operation of the spreader with path dependence, the speed signal of the spreader must
be adjusted to the respective vehicle. You have three different entry possibilities:
- Teach-in
- manual entry
- via distance
Teach-in
Teach-in is a simple method to adjust the speed signal to the respective vehicle. Drive the vehicle with one of the two
preset speeds (15 km/h or 30 km/h) and press the turning knob with the respective indication “Teach-in 15 km/h “ or
“Teach-in 30 km/h”. The value for the speed signal will be determined and saved for displaying the speed at the
control system k-tronic.
For controlling purposes, the current speed is displayed in the upper right corner. The display is calculated via the
value which is stored in the control system for impulses per driven meters.
The impulses per driven meter currently stored in the control system are displayed in the middle column. In case of
minor deviations between the display at the control system k-tronic and the speedometer, the value for the impulses
per driven meter can be corrected by means of the middle turning knob. When exiting the setup screen by means of
button 4
, the last value displayed is maintained for the calculation of the speed display and thus for the calculation of
path dependence.
In case of minor deviations between the display at the control system k-tronic and the speedometer, you can of course
press the respective turning knob anew as soon as the indicated speed of 15 km/h or 30 km/h has been reached. This
can be repeated until the result is satisfactory. When exiting the setup screen, the last determined value for the speed
signal is saved and will be used for the operation of the spreader in case of path-dependence.
If your vehicle supplies a higher value than 650 impulses per meter, please interpose our speed signal divider. By
means of this signal divider, the speed signal from the vehicle is divided down by the factor 10 and fed to the control
system k-tronic. Thus, values up to 6500.0 impulses per driven meter may be recorded.
Engli
Subject to
14 Control system k-
Via distance
You can also determine the speed signal for the spreader via an exactly calculated distance. You drive up to the starting
point of the measuring distance, press the start button, cover the measuring distance directly without stopping and press
the stop button at the end. All impulses between pressing the start and stop button are counted and calculated together
with the entered distance.
It is important to cover the distance directly, each change of direction leads to a wrong measuring
result.
If there is a deviation between the speed signal at the vehicle and the display at the control
system k-tronic, this may have different causes:
- change of direction during driving the measuring distance
- start or end point not exactly reached
- worn tyres of vehicle
- driving with snow chains etc.
Engli
Subject to
Details menu 15
www.kugelmann.c
om
Sensor adjustment
The sensors of the individual drives are set at the manufacturer's works. If, contrary to expectations, a sensor does
not function, the function of the individual sensors can be controlled at this setup screen. If a defective sensor has
been replaced, the new sensor is set to the correct distance with respect to the sensor disc or the motor shaft by
means of this setup screen.
To move the respective drive, the hydraulic system has to be switched on; then, you press the middle turning knob.
At the lower right corner, 2 small numbers appear.
The upper number indicates the current distance from the sensor to the punched disc or motor disc. If the individual
values are smaller than 70, this can lead to a failure during teach-in of the regulator adjustment. In case of values
above 210, the sensor may be destroyed.
The lower number shows the identified impulses. If this number does not change, the sensor may be too far away,
connected incorrectly, the sensor line may be interrupted or the sensor may be defective.
It is important to carry out the setting of the spreading disc sensors and the brine pump with greatest caution, because it
is not possible to see the distance between sensor and the toothed shaft. It is recommended to turn in the sensor only in
small steps and check at regular intervals in between. If the sensor is advanced too far at the beginning, it may be
destroyed by the turning shaft.
Engli
Subject to
16 Control system k-
Regulator adjustment
The control system k-tronic determines own regulator parameters for each hydraulic drive. These regulator parameters
are necessary so that the drive units reach the correct speeds after a spreading pause or a change of settings.
The basic setting of the individual regulators must be carried out at each spreader with the corresponding
hydraulic oil supply.
Parameters
At the control system k-tronic, one set of parameters is part of each hydraulic drive. These 2 parameters are necessary
for the control behavior of the relevant drives. These parameters are determined by means of numerous tests and must
usually not be corrected. The damping stands for the reaction time of the regulation and the ramp stands for the
amount of change.
If a drive should overshoot or undershoot in case other values are regulated, it is wrong to increase
damping in order to faster reach a value. Overshoot or undershoot may only be avoided by reducing
the values.
Teach-in
To reach a correct working result of the spreader, a teach-in of the individual hydraulic motors of the drives is
necessary during first assembly of the spreading unit. This is done via teach-in.
- The hydraulic unit must supply a sufficient quantity of oil. Set the vehicle speed to the upper limit of the
green area.
Tip button 1 to start the teach-in. The drive starts to rotate slowly and is getting faster until the
maximum speed has been reached. This procedure is run through 2 times. In case of danger, it can
Engli
Subject to
Details menu 17
www.kugelmann.c
om
The progress of teach-in is displayed at the appearing bar. At the end of the teach-in, values are
shown and the result whether the attempt was successful or not.
If the teach-in has failed, it has to be determined by means of the displayed values why the error has occurred.
The determined values for 0 to 10 must be in ascending order. If one value is higher than the value that follows,
the teach-in has to be carried out once again because there may be some air bubbles left in the oil circuit.
If several values are out of sequence, the sensor of the respective drive should be checked once again. During sensor
adjustment, no single value of the smaller number must be below 70!
If a value above 1900 exists for one parameter, all values are rejected although a uniform increase of values would be
present. Maybe the oil supply has collapsed or the speed was not constant until the end.
If 0 is present at value “0”, this may mean that the drive rotates without external intervention. Check whether the
handwheels at the hydraulic block are closed, start teach-in again.
Characteristic curve
Caution! In this setup screen, wrong operation may cause the greatest damage. Incorrect operation
may lead to maladjustment of the characteristic curves, this means that the drives may turn very
slowly or not at all. Incorrect operation may also lead to the setting of a characteristic curve which is
not “OK”.
In this setup screen, the desired parameter is set at the left side: 0 - 10
In the middle, the numerical value for the parameter set at the left side is displayed: 0.00 to 20.00 W
At the right column, the determined frequency for this drive is displayed: 0.00 to 300.00 Hz
Error delay
As a continuing oil flow can not be guaranteed at some oil supply systems, e.g. in case of PTO pumps, the individual
errors can be delayed in such cases. For example, the delay of speed monitoring (sensor defective) can be delayed for
the period of one switching operation.
Delayable:
- Oversupply (0 - 25.0 seconds)
Engli
Subject to
18 Control system k-
Increased danger of contusions. During the adjustment of the spreading pattern, do not reach into
the displacement range of the spreading disc suspension.
Current limit
The motor current is monitored to recognize blocking of the servo motor. As the motors may have different sizes, the
current limit for the respective motor size has to be set here.
Example: Linak Type 121P00 -> 1.8 ampere or,
Linak Type M301P1 -> 4.0 ampere
Mechanical limits
The mechanical limits are determined during first commissioning of the spreader and indicate the maximum
displacement travel of the electrical adjustment of the spreading pattern. These settings are made at the manufacturer's
works. If the motor should be replaced, these mechanical limits have to be determined again.
If a new value is entered in the setup screen for min. or max., this new value will be reached immediately. For
controlling purposes, a small number appears at the center of the display showing where the servo motor is located at
the moment.
If, in a column, the value cannot be modified in a certain direction, this is limited by the setting ranges mentioned
above.
If the motor should block, an error tone will sound and the control number at the center does not change anymore. If the
error tone sounds when setting the minimum limit, the value for minimal must be set slightly higher than the displayed
Engli
control number. Example: If the control number remains at 23, the value for MIN. is set to 25.
When setting the maximum limit, the value for MAX. must be set slightly lower than the reached control number.
Subject to
Details menu 19
www.kugelmann.c
om
In case of danger, the movement of the servo motor may be stopped immediately by pushing a
button or a turning knob.
Working range
The setup screen “Spreading pattern control values” is attached to the menu point “Working range”. The set values
may be retrieved by the pressed down middle turning knob in the user interface.
The value LEFT for the working range indicates the setting the servo motor takes for the left spreading image
position. Always indicated in the direction of travel.
The value RIGHT for the working range indicates the setting the servo motor takes for the right spreading image
position.
The value CENTER for the working range indicates the setting the servo motor takes for the middle spreading image
position.
If the value of working range LEFT can no longer be reduced although the mechanical system has not yet reached its
limits, this is due to the fact that at the mechanical limit MINIMUM and the column LEFT the same number is
indicated.
In this case, you can adjust the value at the mechanical limit LEFT.
The same applies for the setting value at the working range RIGHT.
The mutual limitations are visible at the page at the side.
Subject to
20 Control system k-
Spreading materials
In this menu, the individual spreading materials are approved for the user. The following spreading materials can be
selected:
- Salt
- Refined salt
- Grit
- Sawdust
- Special 1
- Special 2
The spreading material brine does only figure in the list if the spreader is equipped with the option brine equipment.
If the line with the corresponding spreading material is selected, it is possible to change between active and
not active by means of button 5.
The spreading materials provided with a at the corresponding menu line are listed at spreading material
selection at the user interface.
Spreading materials which are set at the user levels can not be deactivated here. It is not possible to deactivate the
last spreading material left on the list.
For „MAX“ or „X2“, level 2 must also be observed.
If a spreader should be converted from one single spreading material to another, proceed as
follows:
- The new spreading material must be approved in menu “Spreading material”.
- Replace the old spreading material at all levels of the user interface by the new one.
- Now, deactivate the old spreading material in menu “Spreading material".
The menus of the individual spreading materials contain the following points:
Imp/kg (manually)
Engli
The impulses per kilogram of the respective spreading material are indicated in this setup screen. Possibility to control
and correct the value here, if necessary. The value must be entered for each drive.
Subject to
Details menu 21
www.kugelmann.c
om
Imp/kg (teach-in)
The simplest way to determine the imp/kg is effected via teach-in.
The selected chamber must be filled with the respective spreading material. The screw channel must be filled before
measuring, so that the measuring result may not be distorted.
For the measuring, use a reservoir of an appropriate size (approx. 60 l). In case of a truck-mounted spreader, place
the reservoir below the corresponding screw outlet (with chute folded up). In case of a three-point spreader, place
the spreading disc as far back as possible.
Then, fill the reservoir via “teach”. Hold the left rotary encoder pressed. The drive starts running; the counted
impulses of the drive are shown for controlling purposes.
The fed weight is calculated by means of the impulses/kilogram currently set and displayed in the middle of the
setup screen. Fill the reservoir until the required impulses are counted.
As soon as the required number of impulses has been reached, determine the weight of the supplied spreading
material. Consider the net weight of the used reservoir. If the weighted weight deviates from the display value at the
control system, set the weighted weight by means of the middle turning knob.
To save the values, press the right turning knob “OK”. Only now the new indicated imp/kg are adopted for further
calculation.
If you exit the setup screen without pressing the right turning knob, the value will be rejected and the old imp/kg
remain valid.
When exiting the setup screen, the impulses counted up to this moment will be deleted.
If all hoses are evacuated up to the non-return valve, the setting of the leakage speed can be started. Keep the button 1
(start of pump) pressed and set the speed with the middle turning knob in a way that a constant minimum brine flow is
visible at the nozzle. Values between 2.0 and 5.0 Hz are typical values.
Before you begin measuring, place a reservoir (approx. 60 l) below the brine nozzle. Then, fill the reservoir via “teach”.
Hold the left rotary encoder pressed. The brine pump starts running;
Subject to
22 Control system k-
the counted impulses of the pump are displayed for control purposes.
The supplied volume is calculated by means of the impulses/kilogram currently set and displayed in the
middle of the setup screen. Fill the reservoir until the required impulses are counted.
As soon as the required number of impulses has been reached, determine the weight of the supplied brine. Consider the
net weight of the used reservoir. If the brine weight deviates from the display value at the control system, set the
weighted value by means of the middle turning knob.
To save the values, press the right turning knob “OK”. Only now the new indicated imp/kg are adopted for further
calculation.
If you exit the setup screen without pressing the right turning knob, the value will be rejected and the old imp/kg
remain valid.
When exiting the setup screen, the impulses counted up to this moment will be deleted.
Output counter
The output counter is a counting mechanism at the user interface. If the output counter is approved at options, the values
set here are used for the calculation of the display. The operator can decide at the user menu whether the output
counters should be shown.
Unit
The display unit is set in the middle of the setup screen. The values for the output counter can be set at the display in
“kg”, “l” or without unit. The unit is set separately for each spreading material.
Factor
Setting of ratio between set “imp/kg” and display of output counter in the column “Factor”. If “kg” is selected for the
unit, the factor must be set to 1.00. For unit “1”, the specific density of the spreading material is set.
The output counter does not influence the statistics; it serves only for the driver to assess the filling level of the
individual chambers of the spreader.
Engli
Subject to
Details menu 23
www.kugelmann.c
om
Display increments
It is possible to set individual values for minimum and maximum output rates as well as for the step width per turning
knob detent.
If the user should not be able to change the set spreading density, the minimum and maximum
output rate must be set to the same value.
Step width
Indicates the value of output rate change per turning knob detent. The values are always calculated starting from value 0,
i.e. the last steps up to the minimum or maximum output rate may have a deviating step width.
Setting range: from 1 to 10. Modification in gr/m² per turning knob detent.
Engli
Subject to
24 Control system k-
Spreading width
Different spreading disc types are available for different spreading materials and applications. As each type of
spreading disc has a different influence on the spreading width, the pulses per meter of spreading width have to be set
anew in case the spreading disc is replaced.
The values indicated for the individual types of spreading discs are guide values and must be checked during
spreading. The check can be carried out with simulation speed during standstill.
Setting range: from 0.1 to 1.0 meters. Modification in gr/m² per turning knob detent.
Subject to
Details menu 25
www.kugelmann.c
om
Sub-menu item: spreading width
At the control system, set the spreader to manual mode. Then, set the most used width at spreading width. Now, start
spreading for a certain time (normally, 5 seconds are sufficient) and then, assess the spreading result on the ground.
If the spreading width is too wide, the impulses per meter of spreading width must be reduced. If the spreading width
is too narrow, the impulses per meter of spreading width must be increased.
If a new value has been entered for impulses per meter of spreading width, you have to check this new setting with a
new spreading attempt.
Engli
Subject to
26 Control system k-
Options
Temperature display
If a temperature sensor is connected at the slave of the spreader, this soft switch makes the evaluation visible at the
user interface. If the supply to the temperature sensor is interrupted or if no temperature sensor is connected, 81°C are
displayed.
Display km/h
Setting whether the determined speed of the vehicle should be displayed at the user interface. If the spreader is
operated in manual mode (not path-dependent), the set simulation speed is displayed independently of the setting of
this soft switch.
Motor unit
If the carrier vehicle does not dispose of a sufficient hydraulic supply, the spreader must be supplied with hydraulic
oil by means of a separate motor unit. Two different motor units are available - one diesel unit and one petrol unit.
The diesel unit is also available with dual-circuit equipment for an additional snow plough.
The ignition of the unit must be switched on in order to operate the petrol unit. If the control system
k-tronic is switched off, the running petrol unit will not be switched off automatically.
Subject to
Details menu 27
www.kugelmann.c
om
Sub-menu item: Diesel
If the spreader is operated by means of a diesel unit, this soft switch must be set. The diesel unit may be started and
switched off conveniently from the control system k-tronic. In addition, you can reach the following sub-menu items
of the diesel unit.
Setting range: Idle speed from 700 to 3000 1/min typically 1300 1/min
Working speed from 700 to 3000 1/min typically 1700 1/min
Oil cooler
The diesel hydraulic units are equipped with an additional oil cooler for the hydraulic fluid.
In the attached setup screen “Oil cooler”, the switch-on and switch-off temperatures of the oil cooler are set.
If the diesel unit has been started with the control system k-tronic, it will be switched off as soon as
the control system is switched off.
If the diesel unit is started via the key switch at the unit, it is not possible to switch it off via the
control system k-tronic.
Engli
Subject to
28 Control system k-
Brine equipment
If the spreader is equipped with brine equipment for pre-wetted salt spreading, this soft switch must be set. Then,
proceed with button 6 to reach the sub-menu “Brine equipment” for further settings. Additional entries and setting
possibilities for brine appear at the different menu points:
- the spreading material brine appears at the list of spreading materials
- at sensor adjustment, there is an additional line with brine pump
- at the regulator adjustment, the lines of the brine pump are shown in the sub-menu points parameters,
teach-in and characteristic curve
The sub-menu item “Warning time for dry run” is directly attached
The time in the column ON indicates the delay until the warning appears. If a brine flow is detected before this time
has elapsed, the time begins to count anew as soon as brine stops.
If the warning is shown at the display, the column OFF predefines the time, when brine must flow without
interruption in order to withdraw the warning.
The spreading disc does not stop until the operator changes to the user menu, the control system is switched off or the
Engli
Subject to
Details menu 29
www.kugelmann.c
om
Disc stop at stop
This soft switch indicates whether the spreading disc should stop during spreading (but with the vehicle at standstill) or
whether it should continue to turn. Vehicle standstill is if the speed falls below the minimum settable speed for
spreading. The minimum speed may be set in the options of the details menu in menu point “Km/h when spreader
stops”.
Engli
Subject to
30 Control system k-
Additional level
The function of the level button (Button 5) at the user interface is determined at this menu point. The following
functions are possible.
- Button MAX
- Button X2
- Level 2
If a check mark exists in several lines, the function is assigned to the top line with check mark. If
none of the three points has a check mark at the end of the line, button 5 at the user interface is
without function and the settings of LEVEL1 are valid. This applies to the three values of the
following display increments: minimum setting value, step width and maximum setting value.
If the spreader is operating, the valves are controlled by pressing the MAX button corresponding to the values set
here. The opening of valves is also carried out during vehicle standstill. The spreading width remains unchanged. At
“disc stop - pause” and vehicle standstill, the disc speed is set to the preset spreading width.
If the spreader is in operating mode “PAUSE”, no spreading material is spread if the MAX button is pressed.
If the button MAX is set as additional level, the values of LEVEL1 are valid for normal operation. This
applies for locking and the three display increment values: minimum setting value, step width and
maximum setting value. After approval of the MAX button, the control system k-tronic should be
switched on again via the 0/1 button.
Engli
Subject to
Details menu 31
www.kugelmann.c
om
Sub-menu item: Button X2
When pressing the button “X2” at the user interface, the double quantity of spreading material will be spread for the
length of pressing the button. The spreading width remains unchanged.
If the button X2 is set as additional level, the values of LEVEL1 are valid for operation. This applies
for locking and the three display increment values: minimum setting value, step width and maximum
setting value. After approval of the X2 button, the control system k-tronic should be switched on
again via the 0/1 button.
Engli
Subject to
32 Control system k-
Spreading control
The spreading control does not recognize from which chamber the spreading material is spread.
The spreading control can not check whether one of the two spreading chambers is empty.
The spreading control can be activated at the options of the details menu.
Afterwards, carry out a check during a spreading pause whether the sensitivity of the contact microphone is set
correctly. The spreading material symbol at the user interface must be crossed out.
Engli
Subject to
Details menu 33
www.kugelmann.c
om
Protocol
At the control system k-tronic, you can record the spreading data during driving.
Switch on the protocol at “Options” - a check mark must be placed at the end of the line.
After activation of the protocol, the control system k-tronic must be switched OFF and ON again.
Currently, only the transmission protocol of the company Mobiwork Telematik GmbH, Rosenheimer Strasse 44,
83064 Raubling (www.mobiworx.de) is supported. Transmission protocols of other recording devices upon request.
The data cable of the recording device is connected at the back of the master of the control system k-tronic.
If an update is made at the control system k-tronic, the protocol has to be switched off for the
period of the update. Switch OFF and ON the control system after locking of protocol output.
Engli
Subject to
34 Control system k-
Speed reporting
At the control system k-tronic, you can monitor the speed during the spreading operation.
For this purpose, activate the line with the entry “Speed reporting” in the options. Set the speed limit in the attached
setup screen. Values from 10 to 90 km/h can be set.
If the set speed is exceeded during spreading, a signal tone is emitted. In addition, a message in clear text will appear at
the user interface.
Standstill message
During the spreading operation, the control system k-tronic monitors the speed signal for incoming impulses of the
speed sensor. If these impulses are missing or if there are too few, a message can be issued.
For this purpose, approve the respective line in “Options”. Set the speed limit for the emission of the message at the
attached setup screen.
If the vehicle speed should fall below this speed limit during spreading, the standstill message will be issued. If
the speed signal should fail during driving, the standstill message appears, too.
The message is emitted in clear text at the user interface; in addition, a signal tone is issued. The message remains
active until the next speed signal will be received or if spreading is terminated.
Engli
Subject to
Details menu 35
www.kugelmann.c
om
Input functions
The soft switch must be set in the respective menu line “Input .. Function”. If the input is activated via the soft
switch, it is possible to skip to the attached setup screen.
Functions of inputs
Only one of the functions described below may be assigned to each input.
Please make sure that the same function is not set for 2 inputs. This may lead to significant
disturbances at the control system.
The voltage of the input signals may not exceed the operating voltage of the k-tronic. The current
consumption of an input is max. 100 mA. With an operating voltage of 12 V, the current consumption
is approx. 40 mA, with an operating voltage of 24 V, it is approx. 80 mA. If these loads are too high for
the carrier vehicle, please consult us.
Subject to
36 Control system k-
If the spreading operation should be interrupted, for example during return movement, function 1 may assume
this task. A reversing signal from the carrier vehicle is required for this.
If button 5 of the user level is the MAX button, this MAX operating mode is also reached by means of the input
assigned here in the master. The same conditions apply as with direct operation via the control system, the MAX
values are reached only during spreading and not during PAUSE.
If the X2 state is assigned to button 5 at the user level, the spreading quantity doubles if the button connected
here is pressed.
If button 5 is responsible for level change at the operator level, change the levels by means of the button connected
here.
means of the external button. The rotating beacon only works if the control system is switched on. If the external signal
is present, the rotating beacon may not be switched off by button 1 of the user interface in the control system.
Subject to
Details menu 37
www.kugelmann.c
om
Function 6: Headlights (latching)
By selecting function 6, the working headlight can be switched on/off by means of an external button at the input. To
be able to switch on the working headlight by the external button, the control system must be switched on. If a signal
is present at the external button (vehicle voltage), the working headlight may not be switched off by button 2 of the
user interface in the control system.
In order to reach the spreading image positions via the functions 9 to 15, a short push of a button is
sufficient. The former position of the electrical spreading pattern adjustment is not important. The
new spreading image position is assigned to the currently set operator level; an automatic transfer to
the other operator level will not be effected.
With the external button, the electrical spreading pattern adjustment may be set to the first increment seen from the left.
Subject to
38 Control system k-
Subject to
Details menu 39
www.kugelmann.c
om
Rotating beacon at board net
The control system k-tronic controls the battery voltage of the vehicle for the rotating beacon installed at the
spreader to 12 Volt.
If this is not desired, the rotating beacon can also be supplied directly by the board voltage. Set the menu line to active.
Starting from now, the rotating beacon is directly connected to the available vehicle voltage.
For all rotating beacons supplied with the spreader, an X must be at the end of the menu line so that
the input voltage can be controlled to the necessary 12 Volt. If the rotating beacon with 12 Volt is
accidentally operated with 24 Volt, it will be destroyed.
If a light bulb with 24 Volt should be installed at a spreader supplied with 24 Volt, the board voltage can be connected
to the working headlight by means of this menu line.
For all working headlights supplied with the spreader, X must be at the end of the menu line so that
the input voltage can be controlled to the necessary 12 Volt. If the working headlight with 12 Volt is
accidentally operated with 24 Volt, it will be destroyed.
Subject to
40 Control system k-
Automatic locking
If the same spreading material is set for both chambers, the spreading quantities are coupled in case of automatic
locking. That means that the sum of the spreading quantities is adjusted.
The setting values - i.e. minimum spreading density, display increments, maximum spreading density - now refer to
the sum of the spreading quantities and no longer to the respective chambers.
At spreaders with separate chambers, the spreading quantities are split according to the ratio.
With separated chambers, the spreading material can be set for each chamber separately. With the chambers not
separated, the spreading materials are coupled at the main display.
Double dosing
If the drives of the screws are coupled mechanically or hydraulically, double dosing must be deactivated.
If double dosing is switched off, the two screws are no longer controlled separately, but by a joint control loop.
With double dosing switched off, the appearance of the superordinate menu changes significantly. The function of the
respective menu points remains unchanged.
Engli
Subject to
Details menu 41
www.kugelmann.c
om
Engli
Subject to
Kugelmann Maschinenbau om
e.K. Gewerbepark 1-5 +49 (0) 8860 / 9190-0
87675 Rettenbach www.kugelmann.co
a.A. GERMANY m
office@kugelmann.c
kugelmann
Maschinenbau is a
family-run Allgäu
business with its main
emphasis and tradition
in municipal technology.
With passion, we
manufacture reliable and
pioneering machines - we
love what we do.